1
|
Pihlman J, Magnussen CG, Laitinen TT, Ruohonen S, Pahkala K, Jokinen E, Laitinen TP, Hutri-Kähönen N, Tossavainen P, Taittonen L, Kähönen M, Viikari JSA, Raitakari OT, Juonala M, Nuotio J. Association of number of siblings with preclinical markers of cardiovascular disease. The cardiovascular risk in Young Finns study. INTERNATIONAL JOURNAL OF CARDIOLOGY. CARDIOVASCULAR RISK AND PREVENTION 2024; 20:200227. [PMID: 38115890 PMCID: PMC10726240 DOI: 10.1016/j.ijcrp.2023.200227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 11/30/2023] [Indexed: 12/21/2023]
Abstract
To investigate the association of number of siblings with preclinical cardiovascular disease (CVD) markers in adulthood. The sample comprised 2776 participants (54 % female) from the Cardiovascular Risk in Young Finns Study who had CVD risk factor data measured in childhood in 1980 (aged 3-18 years) and markers of preclinical CVD measured in adulthood. Echocardiography was performed in 2011, and carotid intima-media thickness, carotid distensibility, brachial flow-mediated dilatation, and arterial pulse wave velocity were measured in 2001 or 2007. The association between the number of siblings and preclinical CVD was assessed using generalized linear and logistic regression models. Analyses were stratified by sex as associations differed between sexes. Women with 1 sibling had lower E/e'-ratio (4.9, [95%CI 4.8-5.0]) in echocardiography compared with those without siblings (5.1[4.9-5.2]) and those with ≥2 more siblings (5.1[5.0-5.2]) (P for trend 0.01). Men without siblings had the lowest E/A-ratio (1.4[1.3-1.5]) compared with those with 1 sibling (1.5[1.5-1.5]), or ≥2 siblings (1.5[1.5-1.5]) (P for trend 0.01). Women without siblings had highest left ventricular ejection fraction (59.2 %[58.6-59.7 %]) compared with those with 1 sibling (59.1 %[58.8-59.4 %]), or ≥2 siblings (58.4 %[58.1-58.8 %])(P for trend 0.01). In women, brachial flow-mediated dilatation, a measure of endothelial function, was the lowest among participants with ≥2 siblings (9.4 %[9.0-9.8 %]) compared with those with 1 sibling (10.0 %[9.6-10.3 %]) and those without siblings (10.4 %[9.7-11.0 %])(P for trend 0.03). We observed that number of siblings may be associated with increased risk of heart failure in women. As the associations were somewhat inconsistent in males and females, further research is warranted.
Collapse
Affiliation(s)
- Jukka Pihlman
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
| | - Costan G. Magnussen
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
- Baker Heart and Diabetes Institute, Melbourne, Australia
| | - Tomi T. Laitinen
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
| | - Saku Ruohonen
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
| | - Katja Pahkala
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
- Paavo Nurmi Centre, Sports & Exercise Medicine Unit, Department of Physical Activity and Health, University of Turku, Turku, Finland
| | - Eero Jokinen
- Department of Paediatric Cardiology, Hospital for Children and Adolescents, University of Helsinki, Helsinki, Finland
| | - Tomi P. Laitinen
- Department of Clinical Physiology, University of Eastern Finland and Kuopio University Hospital, Kuopio, Finland
| | - Nina Hutri-Kähönen
- Department of Pediatrics, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Päivi Tossavainen
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, MRC Oulu and Research Unit of Clinical Medicine, University of Oulu, Finland
| | - Leena Taittonen
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, MRC Oulu and Research Unit of Clinical Medicine, University of Oulu, Finland
- Vaasa Central Hospital, Vaasa, Finland
| | - Mika Kähönen
- Department of Clinical Physiology, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Jorma SA. Viikari
- Department of Internal Medicine, University of Turku, Turku, Finland
- Division of Medicine, Turku University Hospital, Turku, Finland
| | - Olli T. Raitakari
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
- Department of Clinical Physiology and Nuclear Medicine, Turku University Hospital, Finland
| | - Markus Juonala
- Department of Internal Medicine, University of Turku, Turku, Finland
- Division of Medicine, Turku University Hospital, Turku, Finland
| | - Joel Nuotio
- Research Centre of Applied and Preventive Cardiovascular Medicine, University of Turku, Turku, Finland
- Centre for Population Health Research, University of Turku and Turku University Hospital, Turku, Finland
- Heart Center, Turku University Hospital and University of Turku, Turku, Finland
| |
Collapse
|
2
|
Antza C, Doundoulakis I, Akrivos E, Stabouli S, Chrysaidou K, Gidaris D, Kotsis V. Estimated Arterial Stiffness and Prediction of Vascular Aging: The Rising of a New Era. Curr Pharm Des 2021; 27:1871-1877. [PMID: 32723254 DOI: 10.2174/1381612826666200728150637] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Accepted: 06/24/2020] [Indexed: 11/22/2022]
Abstract
Arterial stiffness has been associated with cardiovascular events and correlated with cardiovascular risk factors. In the new guidelines of the European Society of Hypertension, the evaluation of arterial stiffness, and specifically carotid-femoral pulse wave velocity (c-f PWV), was taken into account for the detailed screening of the hypertensive population. Despite the importance of arterial stiffness as a target organ damage, the measurement is time-consuming, not practical, needs expensive equipment and experienced staff. For all these reasons, c-f PWV is not recommended for the everyday clinical practice and its current use is restricted for research purposes. The importance of arterial properties in clinical practice and cardiovascular prevention is well known. Hence, the estimation of arterial stiffness and vascular health based on parameters that affect arterial stiffness, but without the use of a machine, is a new promising field. Furthermore, the relationship between age-related MRI abnormalities as well as ultrafast ultrasound with vascular effect gives a new promise for future vascular aging assessment.
Collapse
Affiliation(s)
- Christina Antza
- Hypertension Center, 3rd Department of Medicine, Papageorgiou Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Ioannis Doundoulakis
- Hypertension Center, 3rd Department of Medicine, Papageorgiou Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Evangelos Akrivos
- Hypertension Center, 3rd Department of Medicine, Papageorgiou Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Stella Stabouli
- 1st Department of Pediatrics, Aristotle University Thessaloniki, Hippokration Hospital, Thessaloniki, Thessaloniki, Greece
| | - Katerina Chrysaidou
- 1st Department of Pediatrics, Aristotle University Thessaloniki, Hippokration Hospital, Thessaloniki, Thessaloniki, Greece
| | - Dimos Gidaris
- 1st Department of Pediatrics, Aristotle University Thessaloniki, Hippokration Hospital, Thessaloniki, Thessaloniki, Greece
| | - Vasilios Kotsis
- Hypertension Center, 3rd Department of Medicine, Papageorgiou Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
3
|
Antza C, Doundoulakis I, Akrivos E, Stabouli S, Trakatelli C, Doumas M, Kotsis V. Early Vascular Aging Risk Assessment From Ambulatory Blood Pressure Monitoring: The Early Vascular Aging Ambulatory Score. Am J Hypertens 2018; 31:1197-1204. [PMID: 30239585 DOI: 10.1093/ajh/hpy115] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Accepted: 07/19/2018] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND This study compared the diagnostic accuracy of blood pressure (BP) measurement methods, office BP, ambulatory BP monitoring (ABPM), and home BP, in the identification of early vascular aging (EVA) and developed a score to predict the risk of EVA in hypertensive patients. METHODS Two-hundred eighty-two consecutive subjects (39.7% male) aged 56.8 ± 15.8 years were included. Office and out-of-office BP measurements including ABPM on a usual working day and 7 days home BP monitoring were performed. Carotid-femoral pulse wave velocity (c-f PWV) was measured in all patients. EVA was defined as c-f PWV values higher than the expected for age average values according to European population data. RESULTS In univariate analysis, EVA was significantly correlated with office systolic BP, average 24-hour systolic and diastolic BP, and average 24-hour and office heart rates. The area under the curve for predicting EVA was 0.624 (95% CI 0.551 to 0.697), 0.559 (95% CI 0.484 to 0.635) and 0.565 (95% CI 0.49 to 0.641), for daytime, home, and office systolic BP, respectively. Ambulatory BP variables, age, sex, body mass index, diabetes mellitus (yes/no), and estimated glomerular filtration rate were used to develop a new score for EVA providing a total accuracy of 0.82, 0.84 sensitivity, and 0.78 specificity. CONCLUSIONS In conclusion, the new risk score, Early Vascular Aging Ambulatory score, may accurately identify hypertensive patients with EVA using ABPM values and classic cardiovascular risk factors.
Collapse
Affiliation(s)
- Christina Antza
- 3rd Department of Internal Medicine, Hypertension-24h Ambulatory Blood Pressure Monitoring Center, Papageorgiou Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioannis Doundoulakis
- 3rd Department of Internal Medicine, Hypertension-24h Ambulatory Blood Pressure Monitoring Center, Papageorgiou Hospital, Aristotle University, Thessaloniki, Greece
| | - Evagelos Akrivos
- Laboratory of Computing, Medical Informatics and Biomedical Imaging Technologies, Medical School, Aristotle University of Thessaloniki and 2nd Department of Internal Medicine, Thessaloniki, Greece
| | - Stella Stabouli
- 1st Department of Pediatrics, Hippokration Hospital, Aristotle University, Thessaloniki, Greece
| | - Christina Trakatelli
- 3rd Department of Internal Medicine, Papageorgiou Hospital, Faculty of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Michael Doumas
- Veterans Affairs Medical Center, George Washington University, Washington, DC, USA
| | - Vasilios Kotsis
- 3rd Department of Internal Medicine, Hypertension-24h Ambulatory Blood Pressure Monitoring Center, Papageorgiou Hospital, Aristotle University, Thessaloniki, Greece
| |
Collapse
|
4
|
Abstract
CONTEXT Paper home blood pressure (HBP) charts are commonly brought to physicians at office visits. The precision and accuracy of mental calculations of blood pressure (BP) means are not known. METHODS A total of 109 hypertensive patients were instructed to measure and record their HBP for 1 week and to bring their paper charts to their office visit. Study section 1: HBP means were calculated electronically and compared to corresponding in-office BP estimates made by physicians. Study section 2: 100 randomly ordered HBP charts were re-examined repetitively by 11 evaluators. Each evaluator estimated BP means four times in 5, 15, 30, and 60 s (random order) allocated for the task. BP means and diagnostic performance (determination of therapeutic systolic and diastolic BP goals attained or not) were compared between physician estimates and electronically calculated results. RESULTS Overall, electronically and mentally calculated BP means were not different. Individual analysis showed that 83% of in-office physician estimates were within a 5-mmHg systolic BP range. There was diagnostic disagreement in 15% of cases. Performance improved consistently when the time allocated for BP estimation was increased from 5 to 15 s and from 15 to 30 s, but not when it exceeded 30 s. CONCLUSION Mentally calculating HBP means from paper charts can cause a number of diagnostic errors. Chart evaluation exceeding 30 s does not significantly improve accuracy. BP-measuring devices with modern analytical capacities could be useful to physicians.
Collapse
|
5
|
Niiranen TJ, Mäki J, Puukka P, Karanko H, Jula AM. Office, home, and ambulatory blood pressures as predictors of cardiovascular risk. Hypertension 2014; 64:281-6. [PMID: 24842916 DOI: 10.1161/hypertensionaha.114.03292] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Ambulatory blood pressure (BP) is considered as the gold standard of BP measurement although it has not been shown to be more strongly associated with cardiovascular risk than is home BP. Our objective was to compare the prognostic value of office, home, and ambulatory BP for cardiovascular risk in 502 participants examined in 1992 to 1996. The end point was a composite of cardiovascular mortality, myocardial infarction, stroke, heart failure hospitalization, and coronary intervention. We assessed the prognostic value of each BP in multivariable-adjusted Cox models. The likelihood χ2 ratio value was used to test whether the addition of a BP variable improved the model’s goodness of fit. After a follow-up of 16.1±3.9 years, 70 participants (13.9%) had experienced ≥1 cardiovascular event. Office (systolic/diastolic hazard ratio per 1/1 mm Hg increase in BP, 1.024/1.018; systolic/diastolic 95% confidence interval, 1.009–1.040/0.994–1.043), home (hazard ratio, 1.029/1.028; 95% confidence interval, 1.013–1.045/1.005–1.052), and 24-hour ambulatory BP (hazard ratio, 1.033/1.049; 95% confidence interval, 1.019–1.047/1.023–1.077) were predictive of cardiovascular events. When all 3 BP variables were included in the model simultaneously, only systolic/diastolic ambulatory BP was a significant predictor of cardiovascular events (P=0.002/<0.001). Home systolic/diastolic BP improved the fit of the model only marginally when added to a model including office BP (χ2=3.0/4.0, P=0.09/0.047). Ambulatory BP, however, improved the fit of model more clearly when added to office and home BP (χ2=9.0/12.3, P=0.001/<0.001). Our findings suggest that ambulatory BP is prognostically superior to office and home BP.
Collapse
|
6
|
Target organ damage and masked hypertension in the general population: the Finn-Home study. J Hypertens 2014; 31:1136-43. [PMID: 23466942 DOI: 10.1097/hjh.0b013e32835fa5dc] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The relation of masked hypertension to target organ damage has very seldom been investigated in a general population. METHODS An unselected population cohort (n = 1989 of which 1540 were not treated for hypertension) underwent office (duplicate measurements on one visit by a nurse) and home (duplicate measurements on 7 days) blood pressure (BP) measurements and evaluation of electrocardiographic left ventricular hypertrophy (ECG-LVH, n = 1989/1540), carotid intima-media thickness (cIMT, n = 758/592), and pulse wave velocity (PWV, n = 237/158). ECG-LVH was diagnosed using Cornell voltage criteria. PWV was measured using whole-body impedance cardiography. Masked hypertension was defined as office BP less than 140/90 mmHg with home BP at least 135/85 mmHg and white-coat hypertension as office BP at least 140/90 mmHg and home BP less than 135/85 mmHg. RESULTS Masked and sustained hypertensive individuals had significantly higher age-adjusted and sex-adjusted Cornell voltage, cIMT, and PWV than normotensive individuals. White-coat hypertensive patients had higher age-adjusted and sex-adjusted Cornell voltage than normotensive individuals but significantly lower Cornell voltage and PWV than sustained hypertensive patients. The differences in Cornell voltage and PWV remained significant after adjustment for confounding factors. However, all differences became nonsignificant after adjustment for systolic home BP. CONCLUSION Masked and sustained hypertension is accompanied by increased risk for hypertensive target organ damage, whereas white-coat hypertension seems to be a more benign phenomenon.
Collapse
|
7
|
Home versus ambulatory and office blood pressure in predicting target organ damage in hypertension: a systematic review and meta-analysis. J Hypertens 2012; 30:1289-99. [PMID: 22499289 DOI: 10.1097/hjh.0b013e3283531eaf] [Citation(s) in RCA: 192] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Studies have shown that ambulatory blood pressure (BP) is more closely related to preclinical target organ damage than office measurements. A review and meta-analysis of studies investigating the association of home BP measurements with target organ damage was performed. METHODS A PubMed and Cochrane Library search (1950-2011) revealed 23 studies reporting comparative data of home BP versus ambulatory and/or office measurements in terms of their association with several indices of target organ damage. Correlation coefficients were pooled by random-effects model meta-analysis. RESULTS Fourteen studies (n = 2485) assessing echocardiographic left ventricular mass index (LVMI) showed similar correlations with home (coefficients r = 0.46/0.28, systolic/diastolic) as with ambulatory BP (0.37/0.26, P = NS for difference versus home BP), and superior to office measurements (r = 0.23/0.19, P < 0.001/0.009 for difference versus home BP). Four methodologically heterogeneous studies assessing the glomerular filtration rate (n = 609) could not be pooled or lead to a concrete result. Four studies assessing carotid intima-media thickness (n = 1222), three assessing pulse wave velocity (n = 720) and two assessing urinary protein excretion (n = 156) showed no difference in pooled correlation coefficients with home versus office BP measurements. With all the measurement methods SBP was more closely associated with target organ damage than DBP. CONCLUSION These data suggest that home BP is as good as ambulatory monitoring and superior to office measurements in regard to their association with preclinical organ damage assessed by echocardiographic LVMI. More research is required to evaluate the relationship of home BP with other indices of target organ damage.
Collapse
|
8
|
Alametsä J, Palomäki A, Viik J. Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensor. Med Biol Eng Comput 2011; 49:881-9. [PMID: 21336678 DOI: 10.1007/s11517-011-0746-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2010] [Accepted: 01/31/2011] [Indexed: 11/29/2022]
Abstract
Short and long-term alterations of ballistocardiographic parameters (BCG) were studied in a sitting position using Electromechanical Film (EMFi) sensors. Several physiological parameters were recorded from 48 men of middle age in consecutive recordings and after a 2-week interval. The duration and amplitudes of the signal components were studied. The repeatability index R, the Pearson correlation, and Bland-Altman (BA) repeatability methods were used to determine how repeatable the studied signals are. In consecutive and during 2 week recordings, the Pearson correlation rates for BCG systolic component values (from 0.88/0.83 (T(RJ)) to 0.97/0.78 (A(IJ)), PWV values for the left 0.97/0.67 and right ankle 0.98/0.76) were detected indicating excellent repeatability during consecutive recordings. Respectively BA T(RJ) was -0.002 ± 0.028/-0.004 ± 0.030. Corresponding R values were T(RJ) 0.90/0.82 and right ankle PWV 0.98/0.81. Quite modest blood pressure R values were obtained between 2 week recordings (systolic 0.63, diastolic 0.75, and heart rate 0.59). BCG and PWV measured with EMFi sensors are highly repeatable in consecutive recordings. In longer time interval recordings, BCG is influenced by hemodynamic instability, but in spite of this the reproducibility of the main parameters of the BCG and PWV were better than measured heart rate and blood pressure values.
Collapse
Affiliation(s)
- Jarmo Alametsä
- Department of Biomedical Engineering, Tampere University of Technology, Tampere, Finland.
| | | | | |
Collapse
|
9
|
Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review. Am J Hypertens 2011; 24:123-34. [PMID: 20940712 DOI: 10.1038/ajh.2010.194] [Citation(s) in RCA: 122] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND It is recognized that for the reliable assessment of blood pressure (BP) and the accurate diagnosis of hypertension, out-of-office BP measurement with ambulatory (ABPM) or home BP monitoring (HBPM) is often required. The clinical usefulness of ABPM is well established. However, despite the wide use of HBPM, only in the last decade convincing evidence on its usefulness has accumulated. METHODS Systematic review of the evidence on applying HBPM in the diagnosis and treatment of hypertension (PubMed, Cochrane Library, 1970-2010). RESULTS Sixteen studies in untreated and treated subjects assessed the diagnostic ability of HBPM by taking ABPM as reference. Seven randomized studies compared HBPM vs. office measurements or ABPM for treatment adjustment, whereas many studies compared HBPM with office measurements in assessing the antihypertensive drug effects. Several studies with different design investigated the role of HBPM vs. office measurements in improving patients' compliance with treatment and hypertension control rates. The evidence on the cost-effectiveness of HBPM is limited. The studies reviewed consistently showed moderate diagnostic agreement between HBPM and ABPM, and superiority of HBPM compared to office measurements in diagnosing uncontrolled hypertension, assessing antihypertensive drug effects and improving patients' compliance and hypertension control. Preliminary evidence suggests that HBPM has the potential for cost savings. CONCLUSIONS There is conclusive evidence that HBPM is useful for the initial diagnosis and the long-term follow-up of treated hypertension. These data are useful for the optimal application of HBPM, which is widely used in clinical practice. More studies on the cost-effectiveness of HBPM are needed.
Collapse
|