• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4630701)   Today's Articles (6238)   Subscriber (49778)
For: Zhao Z, Naduvilath T, Flanagan JL, Carnt NA, Wei X, Diec J, Evans V, Willcox MDP. Contact Lens Deposits, Adverse Responses, and Clinical Ocular Surface Parameters. Optom Vis Sci 2010;87:669-74. [DOI: 10.1097/opx.0b013e3181ea1848] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
Number Cited by Other Article(s)
1
Suliński T, Nowak N, Szymański J, Pniewski J. Analysis of Deposition and Diffusion of Cholesterol in Silicone Hydrogel Contact Lenses Using Confocal Microscopy. Vision (Basel) 2024;8:55. [PMID: 39311323 PMCID: PMC11417713 DOI: 10.3390/vision8030055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Revised: 09/06/2024] [Accepted: 09/11/2024] [Indexed: 09/26/2024]  Open
2
Garcia-Queiruga J, Pena-Verdeal H, Ferreiro-Figueiras D, Noya-Padin V, Giraldez MJ, Yebra-Pimentel E. Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month. Ophthalmic Physiol Opt 2024;44:876-883. [PMID: 38712751 DOI: 10.1111/opo.13328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/22/2024] [Accepted: 04/24/2024] [Indexed: 05/08/2024]
3
Contact Lens Wear Induces Alterations of Lactoferrin Functionality in Human Tears. Pharmaceutics 2022;14:pharmaceutics14102188. [PMID: 36297623 PMCID: PMC9612143 DOI: 10.3390/pharmaceutics14102188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022]  Open
4
Ţălu Ş. Advanced morphological analysis of siloxane-hydrogel contact lenses. Microsc Res Tech 2021;84:2702-2715. [PMID: 34036670 DOI: 10.1002/jemt.23833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/29/2021] [Accepted: 05/06/2021] [Indexed: 02/05/2023]
5
Fast versus gradual adaptation of soft monthly contact lenses in neophyte wearers. Cont Lens Anterior Eye 2021;45:101469. [PMID: 34034960 DOI: 10.1016/j.clae.2021.101469] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/30/2021] [Accepted: 05/09/2021] [Indexed: 11/23/2022]
6
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021;15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022]  Open
7
Choy CK, Cho P, Boost MV. Cytotoxicity and effects on metabolism of contact lens care solutions on human corneal epithelium cells. Clin Exp Optom 2021;95:198-206. [DOI: 10.1111/j.1444-0938.2011.00687.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]  Open
8
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021;44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
9
Phan CM, Qiao H, Yee A, Jones L. Deposition of Fluorescently Tagged Lysozyme on Contact Lenses in a Physiological Blink Model. Eye Contact Lens 2021;47:127-133. [PMID: 31789754 DOI: 10.1097/icl.0000000000000683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2019] [Indexed: 11/25/2022]
10
Pucker AD, McGwin G, Franklin QX, Dubey J, Nattis A, Lievens C. Application of systane complete for the treatment of contact lens discomfort. Cont Lens Anterior Eye 2020;44:101399. [PMID: 33323320 DOI: 10.1016/j.clae.2020.12.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 11/30/2020] [Accepted: 12/07/2020] [Indexed: 11/18/2022]
11
Arroyo-Del Arroyo C, Novo-Diez A, Blanco-Vázquez M, Fernández I, López-Miguel A, González-García MJ. Does placebo effect exist in contact lens discomfort management? Cont Lens Anterior Eye 2020;44:101370. [PMID: 33071184 DOI: 10.1016/j.clae.2020.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/18/2020] [Accepted: 09/28/2020] [Indexed: 11/26/2022]
12
Qiao H, Luensmann D, Heynen M, Drolle E, Subbaraman LN, Scales C, Riederer D, Fadli Z, Jones L. In vitro Evaluation of the Location of Cholesteryl Ester Deposits on Monthly Replacement Silicone Hydrogel Contact Lens Materials. Clin Ophthalmol 2020;14:2821-2828. [PMID: 33061266 PMCID: PMC7522414 DOI: 10.2147/opth.s270575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Accepted: 08/22/2020] [Indexed: 11/23/2022]  Open
13
Talens-Estarelles C, García-Marqués JV, Cervino A, García-Lázaro S. Use of digital displays and ocular surface alterations: A review. Ocul Surf 2020;19:252-265. [PMID: 33053438 DOI: 10.1016/j.jtos.2020.10.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 09/15/2020] [Accepted: 10/07/2020] [Indexed: 11/29/2022]
14
Lipid Analysis on Block Copolymer-containing Packaging Solution and Lens Care Regimens: A Randomized Clinical Trial. Optom Vis Sci 2020;97:565-572. [PMID: 32769842 DOI: 10.1097/opx.0000000000001553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
15
Giant papillary conjunctivitis: A review. Ocul Surf 2020;18:396-402. [DOI: 10.1016/j.jtos.2020.03.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 03/29/2020] [Indexed: 11/23/2022]
16
Omali NB, Subbaraman LN, Heynen M, Lada M, Canavan K, Fadli Z, Ngo W, Jones L. Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers. Cont Lens Anterior Eye 2020;44:56-61. [PMID: 32466858 DOI: 10.1016/j.clae.2020.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 11/18/2022]
17
Luensmann D, Omali NB, Suko A, Drolle E, Heynen M, Subbaraman LN, Scales C, Fadli Z, Jones L. Kinetic Deposition of Polar and Non-polar Lipids on Silicone Hydrogel Contact Lenses. Curr Eye Res 2020;45:1477-1483. [PMID: 32281422 DOI: 10.1080/02713683.2020.1755696] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
18
Willcox MD. Tear film, contact lenses and tear biomarkers. Clin Exp Optom 2019;102:350-363. [PMID: 31119796 DOI: 10.1111/cxo.12918] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 03/30/2019] [Accepted: 04/05/2019] [Indexed: 01/09/2023]  Open
19
Uptake and Release of Polyvinyl Alcohol from Hydrogel Daily Disposable Contact Lenses. Optom Vis Sci 2019;96:180-186. [DOI: 10.1097/opx.0000000000001351] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
20
Kojima T. Contact Lens-Associated Dry Eye Disease: Recent Advances Worldwide and in Japan. ACTA ACUST UNITED AC 2018;59:DES102-DES108. [DOI: 10.1167/iovs.17-23685] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
21
Dong Z, Ding X, Li Y, Gan Y, Wang Y, Xu L, Wang Y, Zhou Y, Li J. Short-Term Deposition of PM2.5 Particles on Contact Lens Surfaces: Effect on Oxygen Permeability and Refractive Index. Curr Eye Res 2018;43:1102-1107. [PMID: 29787322 DOI: 10.1080/02713683.2018.1476552] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
22
Lipid Deposition on Contact Lenses when Using Contemporary Care Solutions. Optom Vis Sci 2017;94:919-927. [DOI: 10.1097/opx.0000000000001114] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
23
Schuett BS, Millar TJ. An Experimental Model to Study the Impact of Lipid Oxidation on Contact Lens Deposition In Vitro. Curr Eye Res 2017;42:1220-1227. [DOI: 10.1080/02713683.2017.1307416] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
24
Meibomian Gland Dysfunction and Contact Lens Discomfort. Eye Contact Lens 2017;43:17-22. [PMID: 28002224 DOI: 10.1097/icl.0000000000000351] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
25
Infections in Ocular Prosthesis. CURRENT OPHTHALMOLOGY REPORTS 2016. [DOI: 10.1007/s40135-016-0104-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
26
Contact Lens-Induced Discomfort and Protein Changes in Tears. Optom Vis Sci 2016;93:955-62. [DOI: 10.1097/opx.0000000000000888] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]  Open
27
Tam NK, Pitt WG, Perez KX, Handly E, Glenn AA, Hickey JW, Larsen BG. The role of multi-purpose solutions in prevention and removal of lipid depositions on contact lenses. Cont Lens Anterior Eye 2014;37:405-14. [DOI: 10.1016/j.clae.2014.07.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 06/20/2014] [Accepted: 07/06/2014] [Indexed: 11/24/2022]
28
Ex Vivo Analysis of Cholesterol Deposition for Commercially Available Silicone Hydrogel Contact Lenses Using a Fluorometric Enzymatic Assay. Eye Contact Lens 2014;40:277-82. [DOI: 10.1097/icl.0000000000000052] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
29
Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses. Optom Vis Sci 2014;91:1071-83. [DOI: 10.1097/opx.0000000000000341] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
30
Short-term clinical comparison of two dual-disinfection multipurpose disinfecting solutions. Eye Contact Lens 2013;40:7-11. [PMID: 24296957 DOI: 10.1097/01.icl.0000436270.08502.d3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
31
Tear Lipid Layer and Contact Lens Comfort. Eye Contact Lens 2013;39:247-53. [DOI: 10.1097/icl.0b013e31828af164] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
32
Effect of Lens Care Systems on the Clinical Performance of a Contact Lens. Optom Vis Sci 2013;90:344-50. [DOI: 10.1097/opx.0b013e318288e10c] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
33
Cho P, Boost M. Daily disposable lenses: The better alternative. Cont Lens Anterior Eye 2013;36:4-12. [DOI: 10.1016/j.clae.2012.10.073] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 09/14/2012] [Accepted: 10/02/2012] [Indexed: 01/28/2023]
34
Solutions for Care of Silicone Hydrogel Lenses. Eye Contact Lens 2013;39:24-8. [DOI: 10.1097/icl.0b013e318275e0d9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
35
Biocompatibility in the development of silicone-hydrogel lenses. Eye Contact Lens 2013;39:13-9. [PMID: 23271477 DOI: 10.1097/icl.0b013e31827dbb00] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
36
Predisposing factors for solution-induced corneal staining. Optom Vis Sci 2012;89:1582-9. [PMID: 23080059 DOI: 10.1097/opx.0b013e31826ca27e] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
37
Protein Deposition and Clinical Symptoms in Daily Wear of Etafilcon Lenses. Optom Vis Sci 2012;89:1450-9. [DOI: 10.1097/opx.0b013e318269e583] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
38
Analysis of Meibum and Tear Lipids. Ocul Surf 2012;10:230-50. [DOI: 10.1016/j.jtos.2012.07.004] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2012] [Revised: 07/16/2012] [Accepted: 07/01/2012] [Indexed: 11/19/2022]
39
A Method of Imaging Lipids on Silicone Hydrogel Contact Lenses. Optom Vis Sci 2012;89:E777-87. [DOI: 10.1097/opx.0b013e318253dea9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
40
Protein deposition on contact lenses: The past, the present, and the future. Cont Lens Anterior Eye 2012;35:53-64. [DOI: 10.1016/j.clae.2011.12.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/18/2011] [Accepted: 12/24/2011] [Indexed: 11/19/2022]
41
Preservation of human tear protein structure and function by a novel contact lens multipurpose solution containing protein-stabilizing agents. Eye Contact Lens 2012;38:36-42. [PMID: 22146703 DOI: 10.1097/icl.0b013e31823fdb2a] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA