1
|
Rengier F, Notohamiprodjo M, Weber MA. Thoughts on sustainability in the use of iodinated contrast media in CT: a practice-oriented review based on the example of a hospital and a private practice. ROFO-FORTSCHR RONTG 2024; 196:819-826. [PMID: 38408475 DOI: 10.1055/a-2246-6697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Affiliation(s)
- Fabian Rengier
- Pharmaceuticals Medizin, Radiology, Bayer Vital GmbH, Leverkusen, Germany
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Germany
| | - Mike Notohamiprodjo
- Radiological and Nuclear Medicine Partnership Munich (PR 1432), DIE RADIOLOGIE, Sonnenstraße 17, 80331 München, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
2
|
Viry A, Vitzthum V, Monnin P, Bize J, Rotzinger D, Racine D. Optimization of CT pulmonary angiography for pulmonary embolism using task-based image quality assessment and diagnostic reference levels: A multicentric study. Phys Med 2024; 121:103365. [PMID: 38663347 DOI: 10.1016/j.ejmp.2024.103365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/12/2024] [Accepted: 04/19/2024] [Indexed: 05/12/2024] Open
Abstract
PURPOSE To establish size-specific diagnostic reference levels (DRLs) for pulmonary embolism (PE) based on patient CT examinations performed on 74 CT devices. To assess task-based image quality (IQ) for each device and to investigate the variability of dose and IQ across different CTs. To propose a dose/IQ optimization. METHODS 1051 CT pulmonary angiography dose data were collected. DRLs were calculated as the 75th percentile of CT dose index (CTDI) for two patient categories based on the thoracic perimeters. IQ was assessed with two thoracic phantom sizes using local acquisition parameters and three other dose levels. The area under the ROC curve (AUC) of a 2 mm low perfused vessel was assessed with a non-prewhitening with eye-filter model observer. The optimal IQ-dose point was mathematically assessed from the relationship between IQ and dose. RESULTS The DRLs of CTDIvol were 6.4 mGy and 10 mGy for the two patient categories. 75th percentiles of phantom CTDIvol were 6.3 mGy and 10 mGy for the two phantom sizes with inter-quartile AUC values of 0.047 and 0.066, respectively. After the optimization, 75th percentiles of phantom CTDIvol decreased to 5.9 mGy and 7.55 mGy and the interquartile AUC values were reduced to 0.025 and 0.057 for the two phantom sizes. CONCLUSION DRLs for PE were proposed as a function of patient thoracic perimeters. This study highlights the variability in terms of dose and IQ. An optimization process can be started individually and lead to a harmonization of practice throughout multiple CT sites.
Collapse
Affiliation(s)
- Anaïs Viry
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland.
| | - Veronika Vitzthum
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - Pascal Monnin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - Julie Bize
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - David Rotzinger
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Damien Racine
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| |
Collapse
|
3
|
Langius-Wiffen E, Slotman DJ, Groeneveld J, Ac van Osch J, Nijholt IM, de Boer E, Nijboer-Oosterveld J, Veldhuis WB, de Jong PA, Boomsma MF. External validation of the RSNA 2020 pulmonary embolism detection challenge winning deep learning algorithm. Eur J Radiol 2024; 173:111361. [PMID: 38401407 DOI: 10.1016/j.ejrad.2024.111361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 01/17/2024] [Accepted: 02/08/2024] [Indexed: 02/26/2024]
Abstract
PURPOSE To evaluate the diagnostic performance and generalizability of the winning DL algorithm of the RSNA 2020 PE detection challenge to a local population using CTPA data from two hospitals. MATERIALS AND METHODS Consecutive CTPA images from patients referred for suspected PE were retrospectively analysed. The winning RSNA 2020 DL algorithm was retrained on the RSNA-STR Pulmonary Embolism CT (RSPECT) dataset. The algorithm was tested in hospital A on multidetector CT (MDCT) images of 238 patients and in hospital B on spectral detector CT (SDCT) and virtual monochromatic images (VMI) of 114 patients. The output of the DL algorithm was compared with a reference standard, which included a consensus reading by at least two experienced cardiothoracic radiologists for both hospitals. Areas under the receiver operating characteristic curve (AUCs) were calculated. Sensitivity and specificity were determined using the maximum Youden index. RESULTS According to the reference standard, PE was present in 73 patients (30.7%) in hospital A and 33 patients (29.0%) in hospital B. For the DL algorithm the AUC was 0.96 (95% CI 0.92-0.98) in hospital A, 0.89 (95% CI 0.81-0.94) for conventional reconstruction in hospital B and 0.87 (95% CI 0.80-0.93) for VMI. CONCLUSION The RSNA 2020 pulmonary embolism detection on CTPA challenge winning DL algorithm, retrained on the RSPECT dataset, showed high diagnostic accuracy on MDCT images. A somewhat lower performance was observed on SDCT images, which suggest additional training on novel CT technology may improve generalizability of this DL algorithm.
Collapse
Affiliation(s)
| | - Derk J Slotman
- Department of Radiology, Isala Hospital, Zwolle, the Netherlands; Department of Radiology, University Medical Centre Utrecht, Utrecht University, Utrecht, the Netherlands
| | - Jorik Groeneveld
- Department of Radiology, Isala Hospital, Zwolle, the Netherlands
| | | | - Ingrid M Nijholt
- Department of Radiology, Isala Hospital, Zwolle, the Netherlands; Department of Radiology, University Medical Centre Utrecht, Utrecht University, Utrecht, the Netherlands
| | - Erwin de Boer
- Department of Radiology, Isala Hospital, Zwolle, the Netherlands
| | | | - Wouter B Veldhuis
- Department of Radiology, University Medical Centre Utrecht, Utrecht University, Utrecht, the Netherlands
| | - Pim A de Jong
- Department of Radiology, University Medical Centre Utrecht, Utrecht University, Utrecht, the Netherlands
| | - Martijn F Boomsma
- Department of Radiology, Isala Hospital, Zwolle, the Netherlands; Department of Radiology, University Medical Centre Utrecht, Utrecht University, Utrecht, the Netherlands
| |
Collapse
|
4
|
Rehan S, Kutschera P, Paul E, Lau T, Lau KK. High-pitched tin-filtered CT pulmonary angiography in radiation dose reduction for pulmonary embolism investigations in young females. Emerg Radiol 2023; 30:425-433. [PMID: 37289287 PMCID: PMC10248322 DOI: 10.1007/s10140-023-02142-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 05/16/2023] [Indexed: 06/09/2023]
Abstract
INTRODUCTION Computed tomography pulmonary angiography (CTPA) is the gold standard test to investigate pulmonary embolism (PE). This technique carries significant radiation risk in young females because of radiosensitive breast and thyroid tissues. A high-pitched CT technique offers significant radiation dose reduction (RDR) and minimises breathing artefact. The addition of CT tube tin-filtration may offer further RDR. The aim of this retrospective study was to assess RDR and image quality (IQ) of high-pitch tin-filtered (HPTF)-CTPA against conventional-CTPA. METHODS Retrospective review of consecutive adult females age < 50 years undergoing high pitch tin filtration (HPTF) and standard pitch no tin filtration (SPNF) during a 3-year period beginning in November 2017. CTs in both groups were compared for radiation dose, pulmonary arteries contrast density (Hounsfield units (HU)) and movement artefact. Findings of both groups were compared with the Student's T-test and Mann-Whitney U test, where p < 0.05 being considered significant. Diagnostic quality was also recorded. RESULTS Ten female patients (mean age 33, 6/10 pregnant) in HPTF group and 10 female patients (mean age 36, 1/10 pregnant) in SPNF group were included. The HPTF group achieved 93% RDR (dose length product: 25.15 mGy.cm vs 337.10 mGy.cm, p < 0.01). There was significant contrast density difference between the two groups in the main, left or right pulmonary arteries (322.72 HU, 311.85 HU and 319.41 HU in HPTF group vs 418.60 HU, 405.10 HU and 415.96 HU in SPNF group respectively, p = 0.03, p = 0.03 and p = 0.04). 8/10 HPTF group and 10/10 in the control group were > 250 HU in all three vessels; the remaining 2 HPTF CTPA were > 210HU. All CT scans in both groups were of diagnostic quality and none exhibited movement artefact. CONCLUSION This study was the first to demonstrate significant RDR with the HPTF technique whilst maintaining IQ in patients undergoing chest CTPA. This technique is particularly beneficial in young females and pregnant females with suspected PE.
Collapse
Affiliation(s)
- Saad Rehan
- Monash Department of Surgery, Monash Health, Melbourne, VIC Australia
| | | | - Eldho Paul
- Monash Health Research Precinct, Monash Medical Centre, Melbourne, VIC Australia
| | - Theodore Lau
- Qscan Radiology Clinics, Southport, 123 Nerang Street, QLD Gold Coast, Australia
| | - Kenneth K. Lau
- Monash Imaging, Monash Health, Melbourne, VIC Australia
- School of Clinical Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC Australia
- Department of Oncology, Sir Peter MacCallum, University of Melbourne, Melbourne, VIC Australia
| |
Collapse
|
5
|
Using Routine Chest Computed Tomography to Diagnose Pulmonary Embolism. J Comput Assist Tomogr 2022; 46:888-893. [DOI: 10.1097/rct.0000000000001372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
6
|
Henning MK, Aaløkken TM, Johansen S. Contrast medium protocols in routine chest CT: a survey study. Acta Radiol 2022; 63:351-359. [PMID: 33648351 DOI: 10.1177/0284185121997111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Administration of contrast medium (CM) is an important image quality factor in computed tomography (CT) of the chest. There is no clear evidence or guidelines on CM strategies for chest CT, thus a consensus approach is needed. PURPOSE To survey the potential impact on differences in chest CT protocols, with emphasis on strategies for the administration of CM. MATERIAL AND METHODS A total of 170 respondents were included in this survey, which used two different approaches: (i) an online survey was sent to the members of the European Society of Thoracic Imaging (ESTI); and (ii) an email requesting a copy of their CT protocol was sent to all hospitals in Norway, and university hospitals in Sweden and Denmark. The survey focused on factors affecting CM protocols and enhancement in chest CT. RESULTS The overall response rate was 24% (n = 170): 76% of the respondents used a CM concentration of ≥350 mgI/mL; 52% of the respondents used a fixed CM volume strategy. Fixed strategies for injection rate and delay were also the most common approach, practiced by 73% and 57% of the respondents, respectively. The fixed delay was in the range of 20-90 s. Of the respondents, 56% used flexible tube potential strategies (kV). CONCLUSION The chest CT protocols and CM administration strategies employed by the respondents vary widely, affecting the image quality. The results of this study underline the need for further research and consensus guidelines related to chest CT.
Collapse
Affiliation(s)
- Mette Karen Henning
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Trond Mogens Aaløkken
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
- Faulty of Medicine, University of Oslo, Oslo, Norway
| | - Safora Johansen
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
7
|
Debnath J, Sharma V. Diagnosing pulmonary thromboembolism: Concerns and controversies. Med J Armed Forces India 2022; 78:17-23. [PMID: 35035039 PMCID: PMC8737094 DOI: 10.1016/j.mjafi.2021.05.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 05/24/2021] [Indexed: 01/03/2023] Open
Abstract
Pulmonary thromboembolism (PTE) is an important cause of mortality/morbidity even today despite advancement in clinical understanding as well as diagnostic facilities. Clinical diagnosis of PTE is often challenging because of nonspecific sign/symptoms. Adherence to clinical decision-making protocols and appropriate use of diagnostic modalities like computed tomography pulmonary angiography can resolve the diagnostic dilemma in most cases and help in the overall management of PTE. This article deals with various concerns as well as controversies surrounding accurate diagnosis of PTE as on date.
Collapse
Affiliation(s)
- Jyotindu Debnath
- Consultant, Professor & Head (Radiodiagnosis), Army Hospital (R&R), Delhi Cantt, India,Corresponding author.
| | - Vivek Sharma
- Professor (Radiodiagnosis), Bharati Vidyapeeth Medical College, Pune, India
| |
Collapse
|
8
|
Mulder MMG, Brandts LI, Brüggemann RAG, Koelmann M, Streng AS, Olie RH, Gietema HA, Spronk HMH, van der Horst ICC, Sels JWEM, Wildberger JE, van Kuijk SMJ, Schnabel RM, Ten Cate H, Henskens YMC, van Bussel BCT. Serial markers of coagulation and inflammation and the occurrence of clinical pulmonary thromboembolism in mechanically ventilated patients with SARS-CoV-2 infection; the prospective Maastricht intensive care COVID cohort. Thromb J 2021; 19:35. [PMID: 34059058 PMCID: PMC8165953 DOI: 10.1186/s12959-021-00286-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 05/07/2021] [Indexed: 12/13/2022] Open
Abstract
Background The incidence of pulmonary thromboembolism is high in SARS-CoV-2 patients admitted to the Intensive Care. Elevated biomarkers of coagulation (fibrinogen and D-dimer) and inflammation (c-reactive protein (CRP) and ferritin) are associated with poor outcome in SARS-CoV-2. Whether the time-course of fibrinogen, D-dimer, CRP and ferritin is associated with the occurrence of pulmonary thromboembolism in SARS-CoV-2 patients is unknown. We hypothesise that patients on mechanical ventilation with SARS-CoV-2 infection and clinical pulmonary thromboembolism have lower concentrations of fibrinogen and higher D-dimer, CRP, and ferritin concentrations over time compared to patients without a clinical pulmonary thromboembolism. Methods In a prospective study, fibrinogen, D-dimer, CRP and ferritin were measured daily. Clinical suspected pulmonary thromboembolism was either confirmed or excluded based on computed tomography pulmonary angiography (CTPA) or by transthoracic ultrasound (TTU) (i.e., right-sided cardiac thrombus). In addition, patients who received therapy with recombinant tissue plasminogen activator were included when clinical instability in suspected pulmonary thromboembolism did not allow CTPA. Serial data were analysed using a mixed-effects linear regression model, and models were adjusted for known risk factors (age, sex, APACHE-II score, body mass index), biomarkers of coagulation and inflammation, and anticoagulants. Results Thirty-one patients were considered to suffer from pulmonary thromboembolism ((positive CTPA (n = 27), TTU positive (n = 1), therapy with recombinant tissue plasminogen activator (n = 3)), and eight patients with negative CTPA were included. After adjustment for known risk factors and anticoagulants, patients with, compared to those without, clinical pulmonary thromboembolism had lower average fibrinogen concentration of − 0.9 g/L (95% CI: − 1.6 – − 0.1) and lower average ferritin concentration of − 1045 μg/L (95% CI: − 1983 – − 106) over time. D-dimer and CRP average concentration did not significantly differ, 561 μg/L (− 6212–7334) and 27 mg/L (− 32–86) respectively. Ferritin lost statistical significance, both in sensitivity analysis and after adjustment for fibrinogen and D-dimer. Conclusion Lower average concentrations of fibrinogen over time were associated with the presence of clinical pulmonary thromboembolism in patients at the Intensive Care, whereas D-dimer, CRP and ferritin were not. Lower concentrations over time may indicate the consumption of fibrinogen related to thrombus formation in the pulmonary vessels. Supplementary Information The online version contains supplementary material available at 10.1186/s12959-021-00286-7.
Collapse
Affiliation(s)
- Mark M G Mulder
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.
| | - LIoyd Brandts
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Renée A G Brüggemann
- Department of Internal Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Marcel Koelmann
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Alexander S Streng
- Department of Clinical Chemistry, Central Diagnostic Laboratory, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Renske H Olie
- Department of Internal Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Thrombosis Expert Centre Maastricht and Department of Internal Medicine, Section Vascular Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Hester A Gietema
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,GROW School of Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
| | - Henri M H Spronk
- Thrombosis Expert Centre Maastricht and Department of Internal Medicine, Section Vascular Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Iwan C C van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Jan-Willem E M Sels
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Department of Cardiology, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Joachim E Wildberger
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands.,Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Sander M J van Kuijk
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Ronny M Schnabel
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Hugo Ten Cate
- Department of Internal Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Thrombosis Expert Centre Maastricht and Department of Internal Medicine, Section Vascular Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Yvonne M C Henskens
- Department of Clinical Chemistry, Central Diagnostic Laboratory, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Bas C T van Bussel
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands.,Care and Public Health Research Institute, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
9
|
Euler A, Taslimi T, Eberhard M, Kobe A, Reeve K, Zimmermann A, Krauss A, Gutjahr R, Schmidt B, Alkadhi H. Computed Tomography Angiography of the Aorta-Optimization of Automatic Tube Voltage Selection Settings to Reduce Radiation Dose or Contrast Medium in a Prospective Randomized Trial. Invest Radiol 2021; 56:283-291. [PMID: 33226202 DOI: 10.1097/rli.0000000000000740] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study was to compare the image quality of low-kV protocols with optimized automatic tube voltage selection (ATVS) settings to reduce either radiation dose or contrast medium (CM) with that of a reference protocol for computed tomography angiography (CTA) of the thoracoabdominal aorta. MATERIALS AND METHODS In this institutional review board-approved, single-center, prospective randomized controlled trial, 126 patients receiving CTA of the aorta were allocated to one of three computed tomography protocols: (A) reference protocol at 120 kVp and standard weight-adapted CM dose; (B) protocol at 90 kVp, reduced radiation and standard CM dose; and (C) protocol at 90 kVp, standard radiation and reduced CM dose. All three protocols were performed on a third-generation dual-source computed tomography scanner using the semimode of the ATVS system. The image-task-dependent optimization settings of the ATVS (slider level) were adjusted to level 11 (high-contrast task) for protocols A and B and level 3 (low-contrast task) for protocol C. Radiation dose parameters were assessed. The contrast-to-noise ratios (CNRs) of protocols B and C were tested for noninferiority compared with A. Subjective image quality was assessed using a 5-point Likert scale. RESULTS Size-specific dose estimate was 34.3% lower for protocol B compared with A (P < 0.0001). Contrast medium was 20.2% lower for protocol C compared with A (P < 0.0001). Mean CNR in B and C was noninferior to protocol A (CNR of 30.2 ± 7, 33.4 ± 6.7, and 30.5 ± 8.9 for protocols A, B, and C, respectively). There was no significant difference in overall subjective image quality among protocols (4.09 ± 0.21, 4.03 ± 0.19, and 4.08 ± 0.17 for protocols A, B, and C, respectively; P = 0.4). CONCLUSIONS The slider settings of an ATVS system can be adjusted to optimize either radiation dose or CM at noninferior image quality in low-kV CTA of the aorta. This optimization could be used to extend future ATVS algorithms to take clinical risk factors like kidney function of individual patients into account.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Tilo Taslimi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Adrian Kobe
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Kelly Reeve
- Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zurich, Switzerland
| | - Alexander Zimmermann
- Department of Vascular Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
10
|
Nacif MS. Ventricular Repolarization as a Tool to Monitor Electrical Activity of the Heart. Arq Bras Cardiol 2020; 115:819-820. [PMID: 33295443 PMCID: PMC8452191 DOI: 10.36660/abc.20200959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Affiliation(s)
- Marcelo Souto Nacif
- Complexo Hospitalar de Niterói - Radiologia Cardiovascular, Niterói. RJ - Brasil.,Universidade Federal Fluminense Hospital Universitário Antônio Pedro - Departamento de Radiologia, Niterói, RJ - Brasil
| |
Collapse
|
11
|
Contrast Saline Mixture DualFlow Injection Protocols for Low-Kilovolt Computed Tomography Angiography: A Systematic Phantom and Animal Study. Invest Radiol 2020; 55:785-791. [PMID: 33156586 DOI: 10.1097/rli.0000000000000706] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate a contrast media (CM)-saline mixture administration with DualFlow (DF) to adapt injection protocols to low-kilovolt (kV) computed tomography angiography (CTA). MATERIALS AND METHODS In both a circulation phantom and animal model (5 Goettingen minipigs), 3 injection protocols were compared in dynamic thoracic CTA: (a) DF injection protocol at 80 kV with a iodine delivery rate (IDR) of 0.9 gI/s, a flowrate of 5 mL/s injected with a 60%/40% ratio of iopromide (300 mgI/mL) and saline (dose contrast medium 180 mgI/kg body weight [BW]); (b) reference CTA was performed at 120 kV and a 40% higher iodine dose applied at higher IDR (1.5 gI/s, 5 mL/s iopromide [300 mgI/mL]; no simultaneously administered saline; 300 mgI/kg BW); and (c) conventional single-flow (SF) protocol with identical IDR as the DF protocol at 80 kV (0.9 gI/s, 3 mL/s iopromide [300 mgI/mL]; no simultaneously administered saline; 180 mgI/kg BW). All 3 injection protocols are followed by a saline chaser applied at the same flow rate as the corresponding CM injection. Time attenuation curves representing the vascular bolus shape were generated for pulmonary trunk and descending aorta. RESULTS In the circulation phantom, pulmonary and aortic time attenuation curves for the 80 kV DF injection protocols do not significantly differ from the 80 kV SF and the 120 kV SF reference. In the animal model, the 80 kV DF protocol shows similar pulmonal and aortic peak enhancement when compared with the 120 kV SF and 80 kV SF protocols. Also, the bolus length above an attenuation level of 300 HU reveals no significant differences between injection protocols. However, the time to peak was significantly shorter for the 80 kV DF when compared with the 80 kV SF protocol (15.78 ± 1.9 seconds vs 18.24 ± 2.0 seconds; P = 0.008). CONCLUSION DualFlow injection protocols can be tailored for low-kV CTA by reducing the IDR while overall flow rate remains unchanged. Although no differences in attenuation were found, DF injections offer a shorter time to peak closer to the reference 120 kV protocol.This allows the use of DF injection protocols to calibrate bolus density in low-kV CTA and yields the potential for a more individualized CM administration.
Collapse
|
12
|
Solbak MS, Henning MK, England A, Martinsen AC, Aaløkken TM, Johansen S. Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT. Eur Radiol Exp 2020; 4:57. [PMID: 32915405 PMCID: PMC7486352 DOI: 10.1186/s41747-020-00184-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/12/2020] [Indexed: 12/11/2022] Open
Abstract
Background We investigated the impact of varying contrast medium (CM) densities and x-ray tube potentials on contrast enhancement (CE), image quality and radiation dose in thoracic computed tomography (CT) using two different scanning techniques. Methods Seven plastic tubes containing seven different CM densities ranging from of 0 to 600 HU were positioned inside a commercial chest phantom with padding, representing three different patient sizes. Helical scans of the phantom in single-source mode were obtained with varying tube potentials from 70 to 140 kVp. A constant volume CT dose index (CTDIvol) depending on phantom size and automatic dose modulation was tested. CE (HU) and image quality (contrast-to-noise ratio, CNR) were measured for all combinations of CM density and tube potential. A reference threshold of CE and kVp was defined as ≥ 200 HU and 120 kVp. Results For the medium-sized phantom, with a specific CE of 100–600 HU, the diagnostic CE (200 HU) at 70 kVp was ~ 90% higher than at 120 kVp, for both scan techniques (p < 0.001). Changes in CM density/specific HU together with lower kVp resulted in significantly higher CE and CNR (p < 0.001). When changing only the kVp, no statistically significant differences were observed in CE or CNR (p ≥ 0.094), using both dose modulation and constant CTDIvol. Conclusions For thoracic CT, diagnostic CE (≥ 200 HU) and maintained CNR were achieved by using lower CM density in combination with lower tube potential (< 120 kVp), independently of phantom size.
Collapse
Affiliation(s)
- Marian S Solbak
- Faculty of Health Sciences, Oslo Metropolitan University, Pilestredet 48, 0130, Oslo, Norway
| | - Mette K Henning
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Andrew England
- School of Allied Health Professions, Keele University, Staffordshire, England
| | - Anne C Martinsen
- Faculty of Health Sciences, Oslo Metropolitan University, Pilestredet 48, 0130, Oslo, Norway.,Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway
| | - Trond M Aaløkken
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway.,Faculty of Medicine, University of Oslo, Oslo, Norway
| | - Safora Johansen
- Faculty of Health Sciences, Oslo Metropolitan University, Pilestredet 48, 0130, Oslo, Norway. .,Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway.
| |
Collapse
|
13
|
A Solution for Homogeneous Liver Enhancement in Computed Tomography: Results From the COMpLEx Trial. Invest Radiol 2020; 55:666-672. [PMID: 32898357 DOI: 10.1097/rli.0000000000000693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The aim of the study was to reach homogeneous enhancement of the liver, irrespective of total body weight (TBW) or tube voltage. An easy-to-use rule of thumb, the 10-to-10 rule, which pairs a 10 kV reduction in tube voltage with a 10% decrease in contrast media (CM) dose, was evaluated. MATERIALS AND METHODS A total of 256 patients scheduled for an abdominal CT in portal venous phase were randomly allocated to 1 of 4 groups. In group 1 (n = 64), a tube voltage of 120 kV and a TBW-adapted CM injection protocol was used: 0.521 g I/kg. In group 2 (n = 63), tube voltage was 90 kV and the TBW-adapted CM dosing factor remained 0.521 g I/kg. In group 3 (n = 63), tube voltage was reduced by 20 kV and CM dosing factor by 20% compared with group 1, in line with the 10-to-10 rule (100 kV; 0.417 g I/kg). In group 4 (n = 66), tube voltage was decreased by 30 kV paired with a 30% decrease in CM dosing factor compared with group 1, in line with the 10-to-10 rule (90 kV; 0.365 g I/kg). Objective image quality was evaluated by measuring attenuation in Hounsfield units (HU), signal-to-noise ratio, and contrast-to-noise ratio in the liver. Overall subjective image quality was assessed by 2 experienced readers by using a 5-point Likert scale. Two-sided P values below 0.05 were considered significant. RESULTS Mean attenuation values in groups 1, 3, and 4 were comparable (118.2 ± 10.0, 117.6 ± 13.9, 117.3 ± 21.6 HU, respectively), whereas attenuation in group 2 (141.0 ± 18.2 HU) was significantly higher than all other groups (P < 0.01). No significant difference in attenuation was found between weight categories 80 kg or less and greater than 80 kg within the 4 groups (P ≥ 0.371). No significant differences in subjective image quality were found (P = 0.180). CONCLUSIONS The proposed 10-to-10 rule is an easily reproducible method resulting in similar enhancement in portal venous CT of the liver throughout the patient population, irrespective of TBW or tube voltage.
Collapse
|
14
|
Tailoring Contrast Media Protocols to Varying Tube Voltages in Vascular and Parenchymal CT Imaging: The 10-to-10 Rule. Invest Radiol 2020; 55:673-676. [PMID: 32898358 DOI: 10.1097/rli.0000000000000682] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The latest technical developments in CT have created the possibility for individualized scan protocols at variable kV settings. Lowering tube voltages closer to the K-edge of iodine increases attenuation. However, the latter is also influenced by patient characteristics such as total body weight. To maintain a robust contrast enhancement throughout the patient population in both vascular and parenchymal CT scans, one must adapt the contrast media administration protocols to both the selected kV setting and patient body habitus. This article proposes a simple rule of thumb for how to adapt the contrast media protocol to any kV setting: the 10-to-10 rule.
Collapse
|
15
|
Wu H, Chen X, Zhou H, Qin B, Cao J, Pan Z, Wang Z. An optimized test bolus for computed tomography pulmonary angiography and its application at 80 kV with 10 ml contrast agent. Sci Rep 2020; 10:10208. [PMID: 32576901 PMCID: PMC7311447 DOI: 10.1038/s41598-020-67145-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 05/04/2020] [Indexed: 01/31/2023] Open
Abstract
Computed tomography pulmonary angiography (CTPA) is usually used for pulmonary embolism (PE) detection. However, the determination of scan timing remains a challenge due to the short scan duration of CTPA. We aimed to develop an optimized test bolus to determine scan delay in CTPA. The time-enhancement curves were obtained by measuring the enhancement within a region of interest in the main pulmonary artery and vein. A total of 70 patients were randomly divided into two groups (n = 35 each): the control group underwent CTPA using the test bolus approach and the test group underwent CTPA using the biphasic time-enhancement curves approach. Tube voltages of 100 kVp and 80 kVp and 20 ml and 10 ml contrast agent were adopted in the control and test groups, respectively. The CT numbers, image quality, PE detection was evaluated. There was a point of intersection between the pulmonary artery and vein test bolus enhancement curves. The scan delay time (TDELAY) was obtained based on the time at intersection (TCROSS) and the scan duration (TSD): TDELAY = TCROSS − TSD. The mean CT numbers for pulmonary vein in the control were higher than those in the test group (all p < 0.001). The image quality for the pulmonary arteries in the test group was better than that in the control group (p < 0.01), with artifact reduction in the superior vena cava. Segmental PE could be detected using the optimized protocol. The radiation dose and iodine load in the test group were all lower than those in the control (p < 0.01). We established an approach to calculate the scan delay of CTPA, and this approach could be used for CTPA at 80 kVp with 10 ml contrast agent.
Collapse
Affiliation(s)
- Huiming Wu
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Xiao Chen
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Hao Zhou
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Bin Qin
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Jian Cao
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Zhaochun Pan
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China
| | - Zhongqiu Wang
- Department of Radiology, the Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, China.
| |
Collapse
|
16
|
Dymbe B, Mæland EV, Styve JR, Rusandu A. Individualization of computed tomography protocols for suspected pulmonary embolism: a national investigation of routines. J Int Med Res 2020; 48:300060520918427. [PMID: 32290743 PMCID: PMC7157970 DOI: 10.1177/0300060520918427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Objective Given the extensive use of computed tomography (CT) in radiation-sensitive patients such as pregnant and pediatric patients, and considering the importance of tailoring CT protocols to patient characteristics for both the radiation dose and image quality, this study was performed to investigate the extent to which individualization of CT protocols is practiced across Norway. Methods This cross-sectional study involved collection of CT protocols and administration of a mini-questionnaire to obtain additional information about how CT examinations are individualized. All public hospitals performing CT to detect pulmonary embolism were invited, and 41% participated. Results Tailoring a standard protocol to different patient groups was more common than using dedicated protocols. Most of the available radiation dose-reduction approaches were used. However, implementation of these strategies was not systematic. Children and pregnant patients were examined without using dedicated CT protocols or by using protocol adjustments focusing on radiation dose reduction in 30% and 39% of the hospitals, respectively. Conclusion Practice optimization is needed, especially the development of dedicated CT protocols or guidelines that tailor the existing protocol to pediatric and pregnant patients. Practice might benefit from a more systematic approach to individualization of CT examinations, such as inserting tailoring instructions into CT protocols.
Collapse
Affiliation(s)
- Berit Dymbe
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Elisabeth Vespestad Mæland
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Jorunn Rønhovde Styve
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Albertina Rusandu
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
17
|
|
18
|
Obmann MM, Gehweiler J, Schindera ST, Janetzki J, Boll DT, Benz MR. Clinical evaluation of a novel multibolus contrast agent injection protocol for thoraco-abdominal CT angiography: Assessment of homogeneity of arterial contrast enhancement. Eur J Radiol 2020; 126:108957. [PMID: 32244065 DOI: 10.1016/j.ejrad.2020.108957] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 03/03/2020] [Accepted: 03/09/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the in vivo feasibility of a multibolus contrast agent (CA) injection protocol with a reduced CA volume for thoraco-abdominal CT angiography (CTA) and to compare it to a single-bolus CA injection protocol. METHOD 63 patients who underwent CTA with the multibolus protocol (60 ml CA) were divided in two groups either without (group 1, n = 48) or with (group 2, n = 15) aortic dissection. The aortic contrast enhancement was measured in group 1 using manual ROI analysis (10 segments), as well as semi-automated linear attenuation profiles. A subgroup (n = 18) of group 1, who also underwent imaging with the single-bolus protocol (94 ml CA), was used to compare both protocols. In group 2, differences in attenuation of the true and the false lumen for both the single- and the multibolus protocol were assessed with ROI attenuation measurements in both lumina. Comparisons were made using Wilcoxon test. RESULTS Average attenuation was above 200 HU for 98 % of cases using the multibolus protocol. There was superior contrast homogeneity for the multibolus protocol with a lower standard deviation of attenuation values along the length of the scan (p = 0.003), while average attenuation was higher for the single-bolus protocol (p = 0.002). Prolonged enhancement plateau lead to a more uniform opacification of the true and the false lumen in patients with aortic dissection using the multibolus protocol (p = 0.012). CONCLUSIONS The multibolus protocol in thoraco-abdominal CTA is feasible in patients. It shows consistently high arterial enhancement with superior contrast homogeneity compared to a single-bolus protocol in patients with and without aortic dissection.
Collapse
Affiliation(s)
- Markus M Obmann
- Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Switzerland.
| | - Julian Gehweiler
- Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Switzerland
| | | | - Julia Janetzki
- Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Switzerland
| | - Daniel T Boll
- Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Switzerland
| | - Matthias R Benz
- Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Switzerland.
| |
Collapse
|
19
|
Rotzinger DC, Dunet V, Ilic V, Hugli OW, Meuli RA, Schmidt S. Pulmonary embolism during pregnancy: a 17-year single-center retrospective MDCT pulmonary angiography study. Eur Radiol 2020; 30:1780-1789. [PMID: 31728689 PMCID: PMC7033070 DOI: 10.1007/s00330-019-06501-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 08/23/2019] [Accepted: 10/08/2019] [Indexed: 12/25/2022]
Abstract
OBJECTIVES To determine the prevalence of pulmonary embolism (PE) and alternative diagnoses detected by computed tomography pulmonary angiography (CTPA) in pregnant women; and to assess changes over time regarding radiation dose, technical quality, and examination frequency. MATERIALS AND METHODS This retrospective study included all pregnant women referred for CTPA due to clinically suspected PE over 17 years. Two blinded radiologists reviewed the CTPAs in consensus with regard to PE, alternative diagnoses, and technical quality. We retrieved patient data regarding radiation dose metrics and associated clinical and laboratory parameters. Subgroup comparisons were performed (Wilcoxon and Kruskal-Wallis tests). RESULTS Of the 237 identified patients, 8 (3.3%) were excluded due to inadequate technical CTPA quality, and 229 patients were analyzed (mean age, 31.7 years; mean gestational age, 28 ± 7 weeks). The four different CT systems used over the study period had similar technical quality (p = 0.28). Of 229 patients 16 (7%) patients had PE, 144 (62.9%) had no abnormal findings, and 69 (30.1%) had an alternative diagnosis (consolidation, other pulmonary opacities, pleural effusion, and basal atelectasis). Gestational age, symptoms, and D-dimer levels were not significantly different between patients with or without PE (p > 0.05). Over time, radiation dose exposure decreased by 30% (p < 0.001), while the number of annual examinations increased by > 4-folds. CONCLUSIONS In pregnant women, CTPA rarely indicates PE and more often shows alternative diagnoses. Over 17 years, the use of CTPA in pregnancy has notably increased, while the radiation dose exposure has decreased by one third. KEY POINTS • The use of CTPA in pregnancy has steadily risen over the last 17 years • In pregnant women, CTPA rarely reveals PE and more often shows alternative diagnoses • Recent technical improvements have substantially decreased the radiation dose exposure inherent in CTPA without reducing diagnostic image quality.
Collapse
Affiliation(s)
- David C Rotzinger
- Department of Diagnostic and Interventional Radiology, Emergency Radiology Division, Lausanne University Hospital (CHUV), Rue du Bugnon 46, 1011, Lausanne, Switzerland.
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland.
| | - Vincent Dunet
- Department of Diagnostic and Interventional Radiology, Emergency Radiology Division, Lausanne University Hospital (CHUV), Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland
| | - Vesna Ilic
- Centre d'Imagerie du Nord Vaudois (CINOV), Yverdon-les-Bains, Switzerland
| | - Olivier W Hugli
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland
- Emergency Department, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Reto A Meuli
- Department of Diagnostic and Interventional Radiology, Emergency Radiology Division, Lausanne University Hospital (CHUV), Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland
| | - Sabine Schmidt
- Department of Diagnostic and Interventional Radiology, Emergency Radiology Division, Lausanne University Hospital (CHUV), Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
20
|
|
21
|
Individually Body Weight-Adapted Contrast Media Application in Computed Tomography Imaging of the Liver at 90 kVp. Invest Radiol 2019; 54:177-182. [PMID: 30721159 DOI: 10.1097/rli.0000000000000525] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES The aim of the present study was to evaluate the attenuation and image quality (IQ) of a body weight-adapted contrast media (CM) protocol compared with a fixed injection protocol in computed tomography (CT) of the liver at 90 kV. MATERIALS AND METHODS One hundred ninety-nine consecutive patients referred for abdominal CT imaging in portal venous phase were included. Group 1 (n = 100) received a fixed CM dose with a total iodine load (TIL) of 33 g I at a flow rate of 3.5 mL/s, resulting in an iodine delivery rate (IDR) of 1.05 g I/s. Group 2 (n = 99) received a body weight-adapted CM protocol with a dosing factor of 0.4 g I/kg with a subsequent TIL adapted to the patients' weight. Injection time of 30 seconds was kept identical for all patients. Therefore, flow rate and IDR changed with different body weight. Patients were divided into 3 weight categories; 70 kg or less, 71 to 85 kg, and 86 kg or greater. Attenuation (HU) in 3 segments of the liver, signal-to-noise ratio, and contrast-to-noise ratio were used to evaluate objective IQ. Subjective IQ was assessed by a 5-point Likert scale. Differences between groups were statistically analyzed (P < 0.05 was considered statistically significant). RESULTS No significant differences in baseline characteristics were found between groups. The CM volume and TIL differed significantly between groups (P < 0.01), with mean values in group 1 of 110 mL and 33 g I, and in group 2 of 104.1 ± 21.2 mL and 31.2 ± 6.3 g I, respectively. Flow rate and IDR were not significantly different between groups (P > 0.05). Body weight-adapted protocoling led to more homogeneous enhancement of the liver parenchyma compared with a fixed protocol with a mean enhancement per weight category in group 2 of 126.5 ± 15.8, 128.2 ± 15.3, and 122.7 ± 21.2 HU compared with that in group 1 of 139.9 ± 21.4, 124.6 ± 24.8, and 116.2 ± 17.8 HU, respectively. CONCLUSIONS Body weight-adapted CM injection protocols result in more homogeneous enhancement of the liver parenchyma at 90 kV in comparison to a fixed CM volume with comparable objective and subjective IQ, whereas overall CM volume can be safely reduced in more than half of patients.
Collapse
|
22
|
CT angiography for pulmonary embolism in the emergency department: investigation of a protocol by 20 ml of high-concentration contrast medium. Radiol Med 2019; 125:137-144. [PMID: 31659676 DOI: 10.1007/s11547-019-01098-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 10/15/2019] [Indexed: 12/19/2022]
Abstract
OBJECTIVES To retrospectively compare semi-qualitative and quantitative CT pulmonary angiography (CTPAs) image metrics testing diagnostic performance between protocols performed by 20 or 40 ml of contrast medium (CM) in patients with suspected pulmonary embolism (PE). METHODS A total of 102 CTPAs performed by 20 ml (ultra-low volume: ULV) and 74 CTPAs performed by 40 ml (low volume: LV) protocol for the diagnosis of clinically suspected PE performed between October 2012 and September 2013 were retrieved. High-concentration CM (Iomeprol 400 mgI/ml) was injected at 3 ml/s (iodine delivery rate 1.2 mgI/s). Two radiologists (blinded and independent) semi-qualitatively scored vascular enhancement and image noise according to a five-point visual scoring system. Quantitative analysis was performed by regions of interest quantifying densitometric parameters, such as central and peripheral pulmonary arteries vascular contrast enhancement (CE, threshold for diagnostic CE ≥ 250 HU), and metrics for image noise. Continuous variables were compared by the Student's t test between groups if normally distributed while categorical variables were analyzed with the Chi-squared test. Interobserver agreement was calculated by the weighted kappa test; correlation coefficients were calculated using Pearson's correlation tests. RESULTS The semi-qualitative scores for central and peripheral pulmonary arteries vascular CE were sufficient by ULV, yet inferior than LV (p < 0.001). Semi-qualitative image noise was comparable between ULV and LV, and the interobserver agreement was only fair for quality of peripheral vessels. Agreement on nondiagnostic semi-qualitative parameters was seen in 9/102 (8.8%) ULV CTPAs, in particular associated with massive PE (2/9), pleuro-pulmonary abnormalities (5/9) or without major abnormalities (2/9). Quantitative analysis showed that mean CE was lower in ULV group (p < 0.001), though greater than the diagnostic threshold of 250 HU in both groups. CONCLUSIONS Diagnostic vascular CE (> 250 HU) was obtained in both 20 ml and 40 ml CTPAs. CTPA by 20 ml of CM rendered diagnostic CE for the assessment of pulmonary arteries in patients with clinical suspicion of acute PE. Decreased image quality was mostly associated with massive PE or concomitant pleuro-parenchymal abnormalities.
Collapse
|
23
|
Hendriks BMF, Schnerr RS, Milanese G, Jeukens CRLPN, Niesen S, Eijsvoogel NG, Wildberger JE, Das M. Computed Tomography Pulmonary Angiography during Pregnancy: Radiation Dose of Commonly Used Protocols and the Effect of Scan Length Optimization. Korean J Radiol 2019; 20:313-322. [PMID: 30672171 PMCID: PMC6342764 DOI: 10.3348/kjr.2017.0779] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Accepted: 07/24/2018] [Indexed: 01/21/2023] Open
Abstract
Objective To evaluate the radiation dose for pregnant women and fetuses undergoing commonly used computed tomography of the pulmonary arteries (CTPA) scan protocols and subsequently evaluate the simulated effect of an optimized scan length. Materials and Methods A total of 120 CTPA datasets were acquired using four distinctive scan protocols, with 30 patients per protocol. These datasets were mapped to Cristy phantoms in order to simulate pregnancy and to assess the effect of an effective radiation dose (in mSv) in the first, second, or third trimester of pregnancy, including a simulation of fetal dose in second and third trimesters. The investigated scan protocols involved a 64-slice helical scan at 120 kVp, a high-pitch dual source acquisition at 100 kVp, a dual-energy acquisition at 80/140 kVp, and an automated-kV-selection, high pitch helical scan at a reference kV of 100 kVref. The effective dose for women and fetuses was simulated before and after scan length adaptation. The original images were interpreted before and after scan length adaptations to evaluate potentially missed diagnoses. Results Large inter-scanner and inter-protocol variations were found; application of the latest technology decreased the dose for non-pregnant women by 69% (7.0–2.2 mSv). Individual scan length optimization proved safe and effective, decreasing the fetal dose by 76–83%. Nineteen (16%) cases of pulmonary embolism were diagnosed and, after scan length optimization, none were missed. Conclusion Careful CTPA scan protocol selection and additional optimization of scan length may result in significant radiation dose reduction for a pregnant patient and her fetus, whilst maintaining diagnostic confidence.
Collapse
Affiliation(s)
- Babs M F Hendriks
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.,CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands.
| | - Roald S Schnerr
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Gianluca Milanese
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.,Department of Surgical Sciences, Division of Radiology, University of Parma, Parma, Italy
| | - Cécile R L P N Jeukens
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Sandra Niesen
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Nienke G Eijsvoogel
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.,CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Joachim E Wildberger
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.,CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Marco Das
- Department of Radiology & Nuclear Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands.,Department of Diagnostic and Interventional Radiology, Duisburg, Germany
| |
Collapse
|