1
|
Wang S, Ma JX, Zheng L, Wang H, Yu HL, Chen Y. The ability of SPEEK to promote the proliferation and osteogenic differentiation of BMSCs on PEEK surfaces. Heliyon 2024; 10:e36448. [PMID: 39253123 PMCID: PMC11381825 DOI: 10.1016/j.heliyon.2024.e36448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 07/28/2024] [Accepted: 08/15/2024] [Indexed: 09/11/2024] Open
Abstract
To investigate the ability of sulfonated polyetheretherketone (SPEEK) to promote the proliferation and osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) and compare the effects of different degrees of sulfonation (DS), SPEEK was made with two different DS. The L-SPEEK group had a lower DS, while the H-SPEEK group had a higher DS. The physicochemical properties of both species were evaluated by scanning electron microscopy (SEM), capitilize Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA), X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Then, proliferation and osteogenic differentiation between the two groups and with pure polyetheretherketone (PEEK) were compared after surface inoculation of bone marrow mesenchymal stem cells (BMSCs). Scanning electron microscopy (SEM) revealed that the surface of the PEEK substrates could be smooth or coarse, and the degree of roughness increased with increasing sulfonation. FTIR spectroscopy showed that both the L-SPEEK and H-SPEEK samples contained sulfonic acid. TGA and XRD revealed that the components in the two groups were the same, but the intensities were different. After BMSC inoculation, a CCK8 assay revealed that the cells proliferated more on the H-SPEEK surface and little on the L-SPEEK surface compared with the PEEK surface. Then, osteogenic differentiation was verified by immunofluorescence staining for OCN and Runx2, which indicated that H-SPEEK had the greatest effect on improving differentiation. The results of alizarin red staining (ARS) and alkaline phosphatase staining (APS) also revealed this trend. Sulfonation can change the microsurface of PEEK, which can improve both BMSC proliferation and osteogenic differentiation.
Collapse
Affiliation(s)
- Shuang Wang
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| | - Jun-Xiong Ma
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| | - Liang Zheng
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| | - Hong Wang
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| | - Hai-Long Yu
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| | - Yu Chen
- Department of Orthopedics, General Hospital of Northern Theater Command, No. 83, Wenhua Road, Shenhe District, Shenyang, 110016, China
| |
Collapse
|
2
|
Ge Y, Hu L, Liu J, Ma F, Zhang J, Wang Y, Tang B, Cao S. Peek@ZIF-8(CEL) as a Novel Bone Implant for Large Defect Repair and Enhanced Bone Healing via a Long-Term Stable Bioactive Releaser. ACS APPLIED MATERIALS & INTERFACES 2024; 16:44127-44138. [PMID: 39119797 DOI: 10.1021/acsami.4c11433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/10/2024]
Abstract
The repair of large bone defects poses a significant challenge in orthopedics. Polyetheretherketone (PEEK) is a promising bone substitute, while it suffers a lack of bioactivity. Although several studies have been performed to further improve the bioactivities of PEEK by various surface modifications, PEEK offering long-term, multifaceted biofunctionalities remains still desired. In this study, we introduced metal-organic frameworks (MOFs), specifically ZIF-8 loaded with celecoxib (ZIF-8(CEL)), onto the PEEK surface through dopamine adhesion. The resulting PEEK@ZIF-8(CEL) aims to achieve long-term stable release of Zn ions and CEL for enhanced bone integration. Material characterization and biological experiments confirmed the successful integration of ZIF-8(CEL) onto PEEK and its positive biomedical effects, including creating a positive bone immunological environment and promoting bone growth. This study demonstrates the potential of PEEK@ZIF-8(CEL) as a novel repair material for large bone defects, offering a promising alternative in orthopedic applications.
Collapse
Affiliation(s)
- Yongmei Ge
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Liqiu Hu
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Jiayi Liu
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Fenbo Ma
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Jiarong Zhang
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Yansong Wang
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
| | - Bin Tang
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, PR China
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen, Guangdong 518055, PR China
| | - Shuaishuai Cao
- Department of Stomatology, Shenzhen University General Hospital, Shenzhen University, Shenzhen, Guangdong 518052, PR China
| |
Collapse
|
3
|
Xu Z, Hui J, Lv J, Wei D, Yan Z, Zhang H, Wang J. An investigation of methods to enhance adhesion of conductive layer and dielectric substrate for additive manufacturing of electronics. Sci Rep 2024; 14:10351. [PMID: 38710929 DOI: 10.1038/s41598-024-61327-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/03/2024] [Indexed: 05/08/2024] Open
Abstract
Additive manufacturing of conductive layers on a dielectric substrate has garnered significant interest due to its promise to produce printed electronics efficiently and its capability to print on curved substrates. A considerable challenge encountered is the conductive layer's potential peeling due to inadequate adhesion with the dielectric substrate, which compromises the durability and functionality of the electronics. This study strives to facilitate the binding force through dielectric substrate surface modification using concentrated sulfuric acid and ultraviolet (UV) laser treatment. First, polyetheretherketone (PEEK) and nanoparticle silver ink were employed as the studied material. Second, the surface treatment of PEEK substrates was conducted across six levels of sulfuric acid exposure time and eight levels of UV laser scanning velocity. Then, responses such as surface morphology, roughness, elemental composition, chemical bonding characteristics, water contact angle, and surface free energy (SFE) were assessed to understand the effects of these treatments. Finally, the nanoparticle silver ink layer was deposited on the PEEK surface, and the adhesion force measured using a pull-off adhesion tester. Results unveiled a binding force of 0.37 MPa on unmodified surface, which escalated to 1.99 MPa with sulfuric acid treatment and 2.21 MPa with UV laser treatment. Additionally, cross-approach treatment investigations revealed that application sequence significantly impacts results, increasing binding force to 2.77 MPa. The analysis further delves into the influence mechanism of the surface modification on the binding force, elucidating that UV laser and sulfuric acid surface treatment methods hold substantial promise for enhancing the binding force between heterogeneous materials in the additive manufacturing of electronics.
Collapse
Affiliation(s)
- Zhiguang Xu
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| | - Jizhuang Hui
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China.
| | - Jingxiang Lv
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| | - Dongjie Wei
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| | - Zhiqiang Yan
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| | - Hao Zhang
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| | - Junjie Wang
- Key Laboratory of Road Construction Technology and Equipment of MOE, Chang'an University, Xi'an, China
| |
Collapse
|
4
|
Xie M, Xiao GY, Song ZG, Lu YP. The Formation Process and Mechanism of the 3D Porous Network on the Sulfonated PEEK Surface. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13585-13596. [PMID: 38445618 DOI: 10.1021/acsami.4c00055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
A three-dimensional (3D) porous network can be prepared on the PEEK surface by sulfonation with enhanced osseointegration and antibacterial properties. However, few studies have been conducted on the formation mechanism of a 3D porous network. In this work, the surface and cross-sectional morphologies, chemical compositions, functional groups, surface wettability, and crystalline states of sulfonated PEEK were investigated at different sulfonation times and coagulant concentrations. The results show that the number of nodular structures and broken fibers on the sulfonated PEEK surface as well as the size of macrovoids in the cross sections increase with increasing sulfonation times when water is used as a coagulant. In contrast, dilute sulfuric acid as a coagulant can inhibit the formation of surface porous structures and macrovoids in the cross sections. Moreover, all of the sulfonated PEEK samples have the same chemical compositions but exhibit better hydrophilicity as the number of microsized pores decreases. It is proposed that non-solvent-induced phase separation (NIPS) occurs during the sulfonation process, and the formation mechanism of surface and cross-sectional morphologies is discussed. Furthermore, it is assumed that the air is trapped in the microsized pores, leaving the surface of the 3D porous network in the Cassie-wetting state. All of these preliminary results throw light on the nature of the sulfonation process and may guide further modification of the structures of sulfonated PEEK.
Collapse
Affiliation(s)
- Ming Xie
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan 250061, China
| | - Gui-Yong Xiao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan 250061, China
| | - Zhi-Gang Song
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan 250061, China
| | - Yu-Peng Lu
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan 250061, China
| |
Collapse
|
5
|
Abdulrazzaq S, Ismael Hamad T. Studying and Characterization of Coating of Zein-CaSiO 3 Composite on Polyetheretherketone Implant Material. Int J Dent 2024; 2024:1592439. [PMID: 38524145 PMCID: PMC10960650 DOI: 10.1155/2024/1592439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 12/30/2023] [Accepted: 03/01/2024] [Indexed: 03/26/2024] Open
Abstract
Material-coated implants are placed in the bone and play an essential role in bone regeneration and rapid healing around implants. Polymeric matrix reinforced with ceramic materials is a promising composite material for coating implants. This study aims to determine the effect of mixing various concentrations of zein with CaSiO3 on polyetheretherketone (PEEK) as implant material. The coating was performed using the electrospray method. PEEK disks were used as a control group. The coated disks with different concentrations of zein-CaSiO3 (Group 1: 10% wt, 90% wt), (Group 2: 20% wt, 80% wt), and (Group 3%: 30% wt, 70% wt) were the experimental group. Each group was characterized by atomic force microscopy, field emission scanning electron microscope, Fourier-transform infrared spectroscopy, water contact angle, and adhesion strength. The lowest water contact angle was obtained for Group 1: 10% wt and 90% wt were (26.64° and 27.13°, respectively), and increasing amounts of zein in comparison to quantities of CaSiO3 resulted in increased adhesion strength of the composite material to the substrate. The current study suggested that the higher amount of zein compared to the amount of CaSiO3 mixture coating is achieved by electrospraying, a favorable candidate for coating implants compared to uncoated and coated disks with low concentrations of zein compared to concentrations of CaSiO3.
Collapse
Affiliation(s)
- Sama Abdulrazzaq
- Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| | - Thekra Ismael Hamad
- Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| |
Collapse
|
6
|
Kimble A, Hauschild J, McDonnell G. Affinity and Inactivation of Bacterial Endotoxins for Medical Device Materials. Biomed Instrum Technol 2024; 57:153-162. [PMID: 38170935 PMCID: PMC10764065 DOI: 10.2345/0899-8205-57.4.153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
Endotoxins are high-molecular-weight complexes that contain lipopolysaccharide, protein, and phospholipid originating from the outer membrane of gram-negative bacteria. As gram-negative bacteria are naturally present in a variety of sources, endotoxins are commonly identified as contaminants in manufacturing environments. In industrial applications, endotoxin often is considered difficult to inactivate and to have a strong affinity with surfaces resulting from its hydrophobic chemical structure. This article describes the investigation of the true affinity of endotoxin, from various microbial sources in solution, for medical device material surfaces. In addition, endotoxin reduction was investigated with commonly used sterilization methods such as those based on ionizing radiation, dry and moist heat, and ethylene oxide sterilization. Endotoxin activity was found to be reduced following exposure to a range of sterilization modalities with the degree of activity reduction related to the source of endotoxin and the substrate material upon which it was present.
Collapse
|
7
|
Iwasaki Y. Photoassisted Surface Modification with Zwitterionic Phosphorylcholine Polymers for the Fabrication of Ideal Biointerfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:15417-15430. [PMID: 37899752 DOI: 10.1021/acs.langmuir.3c02696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
Surface modification using zwitterionic 2-methacryloyloxyethyl phosphorylcholine (MPC) polymers is commonly performed to fabricate interfaces that reduce nonspecific fouling by biomolecules and cells. Accordingly, several clinically used devices, such as guide wires, stents, oxygenators, left ventricular assist devices, and microcatheters have been modified using MPC polymers. The specific types of surface modifications vary across substrates and applications. Recently, photoreactions have garnered attention for surface modification due to their stability and tunability. This review highlights various studies that employed photoreactions to modify surfaces using MPC polymers, especially photoinduced graft polymerization of MPC. In addition to antifouling materials, several micromanipulated, long-lasting hydrophilic, and super antiwear surfaces are summarized. Furthermore, several photoreactive MPC polymers that can be used to control interactions between biomolecules and materials are presented along with their potential to form selective recognition surfaces that target biomolecules for biosensors and diagnostic devices.
Collapse
Affiliation(s)
- Yasuhiko Iwasaki
- Department of Chemistry and Materials Engineering, Faculty of Chemistry, Materials and Bioengineering, Kansai University 3-3-35 Yamate-cho, Suita-shi, Osaka 564-8680, Japan
| |
Collapse
|
8
|
Zheng W, Wu D, Zhang Y, Luo Y, Yang L, Xu X, Luo F. Multifunctional modifications of polyetheretherketone implants for bone repair: A comprehensive review. BIOMATERIALS ADVANCES 2023; 154:213607. [PMID: 37651963 DOI: 10.1016/j.bioadv.2023.213607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/16/2023] [Accepted: 08/25/2023] [Indexed: 09/02/2023]
Abstract
Polyetheretherketone (PEEK) has emerged as a highly promising orthopedic implantation material due to its elastic modulus which is comparable to that of natural bone. This polymer exhibits impressive properties for bone implantation such as corrosion resistance, fatigue resistance, self-lubrication and chemical stability. Significantly, compared to metal-based implants, PEEK implants have mechanical properties that are closer to natural bone, which can mitigate the "stress shielding" effect in bone implantation. Nevertheless, PEEK is incapable of inducing osteogenesis due to its bio-inert molecular structure, thereby hindering the osseointegration process. To optimize the clinical application of PEEK, researchers have been working on promoting its bioactivity and endowing this polymer with beneficial properties, such as antibacterial, anti-inflammatory, anti-tumor, and angiogenesis-promoting capabilities. Considering the significant growth of research on PEEK implants over the past 5 years, this review aims to present a timely update on PEEK's modification methods. By highlighting the latest advancements in PEEK modification, we hope to provide guidance and inspiration for researchers in developing the next generation bone implants and optimizing their clinical applications.
Collapse
Affiliation(s)
- Wenzhuo Zheng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Dongxu Wu
- West China School of Pharmacy, Sichuan University, Chengdu 610041, China
| | - Yaowen Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Yankun Luo
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Lei Yang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Xiangrui Xu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Feng Luo
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China; Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China.
| |
Collapse
|
9
|
Lyu X, Kanda R, Tsuda S, Hashimoto Y, Fujii T, Kashiwagi K. Novel Carboxylation Method for Polyetheretherketone (PEEK) Surface Modification Using Friedel-Crafts Acylation. Int J Mol Sci 2023; 24:15651. [PMID: 37958636 PMCID: PMC10650194 DOI: 10.3390/ijms242115651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023] Open
Abstract
Recently, polyetheretherketone (PEEK) has shown promising dental applications. Surface treatment is essential for dental applications owing to its poor surface energy and wettability; however, no consensus on an effective treatment method has been achieved. In this study, we attempted to carboxylate PEEK sample surfaces via Friedel-Crafts acylation using succinic anhydride and AlBr3. The possibility of further chemical modifications using carboxyl groups was examined. The samples were subjected to dehydration-condensation reactions with 1H,1H-pentadecafluorooctylamine and N,N'-dicyclohexylcarbodiimide. Furthermore, the sample's surface properties at each reaction stage were evaluated. An absorption band in the 3300-3500 cm-1 wavenumber region was observed. Additionally, peak suggestive of COOH was observed in the sample spectra. Secondary modification diminished the absorption band in 3300-3500 cm-1 and a clear F1s signal was observed. Thus, Friedel-Crafts acylation with succinic anhydride produced carboxyl groups on the PEEK sample surfaces. Further chemical modification of the carboxyl groups by dehydration-condensation reactions is also possible. Thus, a series of reactions can be employed to impart desired chemical structures to PEEK surfaces.
Collapse
Affiliation(s)
- Xinghui Lyu
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Ryuhei Kanda
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Susumu Tsuda
- Department of Chemistry, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Yoshiya Hashimoto
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
- Department of Biomaterial, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| | - Takamasa Fujii
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Kosuke Kashiwagi
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| |
Collapse
|
10
|
Hansda B, Mondal B, Hazra S, Banerjee A. Metal ion-induced assembly of dipeptide-attached perylenediimide for fluorometric "turn on" detection of biologically important small molecule. J Pept Sci 2023; 29:e3492. [PMID: 37038654 DOI: 10.1002/psc.3492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 03/16/2023] [Accepted: 04/03/2023] [Indexed: 04/12/2023]
Abstract
A dipeptide-appended perylenediimide (PDI-CFF) fluorescent molecule was designed, synthesized, and characterized. Though the molecule does not dissolve in any individual solvent, it dissolves well in an organic/water mixed solvent system such as tetrahydrofuran/water. This new fluorescent molecule was self-assembled in a tetrahydrofuran/water mixture to form both nanofibrous network structures and a nano ring structure. It has shown nanofibril morphology by the interactions with ferric ions (PDI-CFF/Fe3+ system) with diminishing fluorescent property. Interestingly, L-ascorbic acid (LAA) interacts with the PDI-CFF/Fe3+ system, showing turn-on fluorescence. Another interesting feature is that the minimum detection limits for Fe3+ ions and LAA are at the submicromolar levels of 6.2 × 10-8 and 3 × 10-8 M, respectively. Moreover, the fluorescent (10 μM) signals can be monitored by the naked eye under handheld UV lamp irradiation at 365 nm, and this is very convenient for the real application. In this study, the molecule offers the opportunity for processing these sequential fluorescence responses in order to fabricate a implication logic gate that includes NOT, AND, and OR simple logic gates using chemical stimuli (ferric ions and LAA) as inputs and fluorescence emission at 536 nm as output. The detailed mechanism of interactions of Fe3+ with PDI-CFF and LAA with the PDI-CFF/Fe3+ system is vividly studied by using Fourier transform infrared (FT-IR) analysis and fluorescence. Moreover, this new molecule was reusable for several times without significant loss of its activity. The construction of logic gates using biologically important molecules/ions holds future promise for the design and development of new bio-logic gates.
Collapse
Affiliation(s)
- Biswanath Hansda
- School of Biological Sciences, Indian Association for the Cultivation of Science, Kolkata, India
| | - Biplab Mondal
- School of Biological Sciences, Indian Association for the Cultivation of Science, Kolkata, India
| | - Soumyajit Hazra
- School of Biological Sciences, Indian Association for the Cultivation of Science, Kolkata, India
| | - Arindam Banerjee
- School of Biological Sciences, Indian Association for the Cultivation of Science, Kolkata, India
| |
Collapse
|
11
|
Chayanun S, Chanamuangkon T, Boonsuth B, Boccaccini AR, Lohwongwatana B. Enhancing PEEK surface bioactivity: Investigating the effects of combining sulfonation with sub-millimeter laser machining. Mater Today Bio 2023; 22:100754. [PMID: 37593219 PMCID: PMC10430171 DOI: 10.1016/j.mtbio.2023.100754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/20/2023] [Accepted: 07/28/2023] [Indexed: 08/19/2023] Open
Abstract
Due to its superior mechanical properties and chemical stability, Polyetheretherketone (PEEK) has emerged as an alternative to conventional metal implants. However, the bio-inertness of PEEK's surface has limited its applications. Ambient sulfonation has been adopted to enhance bioactivity, but its nanoscale topographic changes are insufficient for implant-bone interlock. To further improve bone-implant interlock, this study employs CO2 laser machining to create sub-millimeter (0.5 mm) grooves on PEEK's surface, aiming to encourage bone ingrowth and strengthen the implant-bone interface. This research investigated the physical and chemical properties and bio-interaction of PEEK surface modified by sulfonation (SPEEK), laser machining (L-PEEK), and combination of both technique (L-SPEEK). X-ray photoelectron spectroscopy (XPS) spectra revealed that sulfonation compensates for the surface chemical shift instigated by laser ablation, aligning the surface chemistry of L-SPEEK with that of SPEEK. Furthermore, L-PEEK surfaces presented pores with sizes ranging from 1 to 600 μm, while SPEEK surfaces exhibited pores between 5 and 700 nm. All tested samples demonstrated non-cytotoxicity, with L-SPEEK exhibiting the highest mineralization and ALP activity as 2 and 2.1 times that of intrinsic PEEK, after 21 days of incubation. Microscopic imaging reveals a notably higher extracellular content on L-SPEEK compared to the other groups. This study underscores the potential of combining sub-millimeter laser machining with sulfonation in enhancing early osteogenic markers, providing a promising pathway for future PEEK-based orthopedic applications.
Collapse
Affiliation(s)
- Slila Chayanun
- Biomedical Engineering Program, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand
- Biomedical Engineering Research Center, Chulalongkorn University, Bangkok, Thailand
- Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg, Cauerstr. 6, 91058, Erlangen, Germany
| | - Theerapat Chanamuangkon
- Biomaterial Testing Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Budsaraporn Boonsuth
- Oral Biology Research Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Aldo R. Boccaccini
- Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg, Cauerstr. 6, 91058, Erlangen, Germany
| | - Boonrat Lohwongwatana
- Biomedical Engineering Research Center, Chulalongkorn University, Bangkok, Thailand
- Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
12
|
Dua R, Sharufa O, Terry J, Dunn W, Khurana I, Vadivel J, Zhang Y, Donahue HJ. Surface modification of Polyether-ether-ketone for enhanced cell response: a chemical etching approach. Front Bioeng Biotechnol 2023; 11:1202499. [PMID: 37744253 PMCID: PMC10517429 DOI: 10.3389/fbioe.2023.1202499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/28/2023] [Indexed: 09/26/2023] Open
Abstract
Polyether-ether-ketone (PEEK) is increasingly becoming popular in medicine because of its excellent mechanical strength, dimensional stability, and chemical resistance properties. However, PEEK being bioinert, has weak bone osseointegration properties, limiting its clinical applications. In this study, a porous PEEK structure was developed using a chemical etching method with 98 wt% sulfuric acids and three post-treatments were performed to improve bone cell adhesion and proliferation. Four groups of PEEK samples were prepared for the study: Control (untreated; Group 1); Etched with sulfuric acid and washed with distilled water (Group 2); Etched with sulfuric acid and washed with acetone and distilled water (Group 3); and Etched with sulfuric acid and washed with 4 wt% sodium hydroxide and distilled water (Group 4). Surface characterization of the different groups was evaluated for surface topology, porosity, roughness, and wettability using various techniques, including scanning electron microscopy, profilometer, and goniometer. Further chemical characterization was done using Energy-dispersive X-ray spectroscopy to analyze the elements on the surface of each group. Bone cell studies were conducted using cell toxicity and alkaline phosphatase activity (ALP) assays. The SEM analysis of the different groups revealed porous structures in the treatment groups, while the control group showed a flat topology. There was no statistically significant difference between the pore size within the treated groups. This was further confirmed by the roughness values measured with the profilometer. We found a statistically significant increase in the roughness from 7.22 × 10-3 μm for the control group to the roughness range of 0.1 µm for the treated groups (Groups 2-4). EDX analysis revealed the presence of a 0.1% weight concentration of sodium on the surface of Group 4, while sulfur weight percentage concentration was 1.1%, 0.1%, and 1.4% in groups 2, 3, and 4, respectively, indicating different surface chemistry on the surface due to different post-treatments. Cell toxicity decreased, and ALP activity increased in groups 3 and 4 over 7 days compared with the control group. It is demonstrated that the surface modification of PEEK using a chemical etching method with post-processing with either acetone or sodium hydroxide provides a nano-porous structure with improved properties, leading to enhanced osteoblastic cell differentiation and osteogenic potential.
Collapse
Affiliation(s)
- Rupak Dua
- American Dental Association Science and Research Institute (ADASRI), Gaithersburg, MD, United States
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Onessa Sharufa
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Joi Terry
- Department of Biology, Hampton University, Hampton, VA, United States
| | - William Dunn
- The New Horizons Governor’s School for Science and Technology, Hampton, VA, United States
| | - Indu Khurana
- Department of Economics and Business, Hampden-Sydney College, Hampden-Sydney, VA, United States
| | - Jagasivamani Vadivel
- Department of Chemical Engineering, Hampton University, Hampton, VA, United States
| | - Yue Zhang
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Henry J. Donahue
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States
| |
Collapse
|
13
|
Su J, Wu Q, Xing X, Li D, Ou Y, He K, Lin H, Qiu Y, Rausch-Fan X, Chen J. Effect of sulfonation time on physicochemical, osteogenic, antibacterial properties and biocompatibility of carbon fiber reinforced polyether ether ketone. J Mech Behav Biomed Mater 2023; 145:105979. [PMID: 37467553 DOI: 10.1016/j.jmbbm.2023.105979] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/13/2023] [Accepted: 06/16/2023] [Indexed: 07/21/2023]
Abstract
The carbon fiber reinforced polyetheretherketone (CFR-PEEK) has been increasingly used in orthopedics dentistry due to its excellent biocompatibility and mechanical properties. However, the biological inertness and poor antibacterial activity limit its clinical applications. This paper focused on the performances of CFR-PEEK with porous morphology that were exposed to different sulfonation periods (1, 3, 5, and 10 min, corresponding to CP-S1, CP-S3, CP-S5, and CP-S10, respectively). Residual sulfuric acid was removed by acetone rinsing, NaOH immersion, and hydrothermal treatment before in vitro and in vivo studies. The results showed some significant difference in the physicochemical properties, including energy dispersive X-ray spectroscopy (EDS) map of sulfur atoms, X-ray photoelectron spectroscopy (XPS) of valences of sulfur ions, Fourier transformation infrared spectroscopy (FTIR), hydrophilicity, hardness, and elastic modulus among CP-S3, CP-S5, and CP-S10. However, CP-S5 and CP-S10 were more effective in promoting the proliferation, adhesion, and osteogenic differentiation of seeded bone mesenchymal stem cells (BMSCs) and growth inhibition of S. aureus and P. gingivalis compared with other groups. Furthermore, the CP-S5 and CP-S10 samples achieved better cranial bone repair than the non-sulfonation group in a rat model. Therefore, it can be inferred that both 5 and 10 min are viable sulfonation durations for 30% CFR-PEEK. These findings provide a theoretical basis for developing CFR-PEEK for clinical applications.
Collapse
Affiliation(s)
- Jingjing Su
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Qingshi Wu
- College of Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, China
| | - Xiaojie Xing
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Dexiong Li
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Yanjing Ou
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Kaixun He
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Hanyu Lin
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Yubei Qiu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China
| | - Xiaohui Rausch-Fan
- Division of Conservative Dentistry and Periodontology, School of Dentistry, Medical University of Vienna, Vienna, Austria.
| | - Jiang Chen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350000, China.
| |
Collapse
|
14
|
Pu F, Yu Y, Zhang Z, Wu W, Shao Z, Li C, Feng J, Xue L, Chen F. Research and Application of Medical Polyetheretherketone as Bone Repair Material. Macromol Biosci 2023; 23:e2300032. [PMID: 37088909 DOI: 10.1002/mabi.202300032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 04/01/2023] [Indexed: 04/25/2023]
Abstract
Polyetheretherketone (PEEK) can potentially be used for bone repair because its elastic modulus is similar to that of human natural bone and good biocompatibility and chemical stability. However, its hydrophobicity and biological inertness limit its application in the biomedical field. Inspired by the composition, structure, and function of bone tissue, many strategies are proposed to change the structure and functionality of the PEEK surface. In this review, the applications of PEEK in bone repair and the optimization strategy for PEEK's biological activity are reviewed, which provides a direction for the development of multifunctional bone repair materials in the future.
Collapse
Affiliation(s)
- Feifei Pu
- Department of Orthopedics, Traditional Chinese and Western Medicine Hospital of Wuhan (Wuhan No.1 Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Yihan Yu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Zhicai Zhang
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Wei Wu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Zengwu Shao
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Chao Li
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Jing Feng
- Department of Orthopedics, Traditional Chinese and Western Medicine Hospital of Wuhan (Wuhan No.1 Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, China
| | - Longjian Xue
- School of Power and Mechanical Engineering, Wuhan University, Wuhan, Hubei, 430072, China
| | - Fengxia Chen
- Department of Radiation and Medical Oncology, Zhongnan Hospital, Wuhan University, Wuhan, Hubei, 430071, China
| |
Collapse
|
15
|
Padinjarathil H, Vilasini V, Balasubramanian R, Drago C, Dattilo S, Ramani P. Sulfonated Polyether Ketone Membranes Embedded with Nalidixic Acid-An Emerging Controlled Drug Releaser. Polymers (Basel) 2023; 15:3631. [PMID: 37688257 PMCID: PMC10490094 DOI: 10.3390/polym15173631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/24/2023] [Accepted: 08/25/2023] [Indexed: 09/10/2023] Open
Abstract
The effective administration of medication has advanced over decades, but the medical community still faces significant demand. Burst release and inadequate assimilation are major drawbacks that affect wound healing efficiency, leading to therapy failure. The widespread application of polymers in biomedical research is significant. The polyether ether ketone (PEEK) family is known for its biocompatibility, inertness, and semi-crystalline thermoplastic properties. In our present studies, we have chosen a member of this family, polyether ketone (PEK), to explore its role as a drug carrier. The PEK backbone was subjected to sulfonation to increase its hydrophilicity. The response surface methodology (RSM) was used to optimize the sulfonation process based on the time, degree of sulfonation, and temperature. The PEK polymer was sulfonated using sulfuric acid at 150 °C for 6 h; back titration was performed to quantify the degree of sulfonation, with 69% representing the maximum sulfonation. SPEK and nalidixic sodium salt were dissolved in dichloroacetic acid to create a thin membrane. The physiological and morphological properties were assessed for the SPEK membrane. The studies on drug release in distilled water and a simulated body fluid over the course of 24 h revealed a controlled, gradual increase in the release rate, correlating with a mathematical model and demonstrating the zero-order nature of the drug release. Hemolysis on the SPEK membrane revealed lower toxicity. The SPEK membrane's biocompatibility was established using in vitro cytotoxicity tests on the Vero (IC50: 137.85 g/mL) cell lines. These results confirm that the SPEK membranes are suitable for sustained drug release.
Collapse
Affiliation(s)
- Himabindu Padinjarathil
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
- Department of Chemical Engineering and Materials Science, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Vidya Vilasini
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Rajalakshmi Balasubramanian
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Carmelo Drago
- Institute of Biomolecular Chemistry, CNR, via Paolo Gaifami 18, I-95126 Catania, Italy;
| | - Sandro Dattilo
- Institute for Polymer, Composite and Biomaterials, CNR, via Paolo Gaifami 18, I-95126 Catania, Italy
| | - Prasanna Ramani
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
- Center of Excellence in Advanced Materials and Green Technologies (CoE–AMGT), Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| |
Collapse
|
16
|
Liu C, Huang Z, Zhu J, Liu X, Zhu B, Zheng D, Yang B, Tao R, Cai C, Chen X, Liu J, Deng Z. Near-ultraviolet irradiation to stimulate unmodified polyether ether ketone to achieve stable and sustainable antibacterial activity. Colloids Surf B Biointerfaces 2023; 229:113441. [PMID: 37422990 DOI: 10.1016/j.colsurfb.2023.113441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 07/02/2023] [Accepted: 07/03/2023] [Indexed: 07/11/2023]
Abstract
OBJECTIVES This study aims to investigate the cytotoxicity and sustainable antibacterial activity of unmodified PEEK under specific wavelength light treatment (365 nm), and its antibacterial mechanism was also preliminarily discussed. METHODS A near-ultraviolet source with a wavelength of 365 nm and a power of 5 W were selected. The irradiation time was 30 min, and the distance was 100 mm. A water contact angle tester was used to characterize the surface of the PEEK after 1-15 light treatments. MC3TC-E1 cells were used to evaluate the cytotoxicity of the materials under light treatment. Five kinds of common oral bacteria were detected in vitro, and antibacterial efficiency was determined by colony-forming unit (CFU) and scanning electron microscope (SEM). The antibacterial mechanism of PEEK under light was preliminarily discussed by spectrophotometry. The membrane rupture of Staphylococcus aureus and Escherichia coli was detected by lactate dehydrogenase. Staphylococcus aureus and Staphylococcus mutans were selected for the cyclic antibacterial test. Statistical analysis was performed by one-way analysis of variance and Tukey multiple range test. A significance level of 0.05 was considered (α = 0.05). RESULTS The results of the cell experiment showed that PEEK had no cytotoxicity (P > 0.05). CFU results showed that PEEK had an obvious antibacterial effect on Staphylococcus aureus, Staphylococcus mutans, Staphylococcus gordonii and Staphylococcus sanguis, but had no antibacterial effect on Escherichia coli (P < 0.05). The SEM results also verified the above antibacterial effect. The existence of singlet oxygen was confirmed by spectrophotometry. Meanwhile, the rupture of Staphylococcus aureus membrane was verified by lactate dehydrogenase assay. The water contact angle of the PEEK surface did not change significantly after 15 cycles of light treatment. Cyclic antibacterial experiments showed that the antibacterial effect was sustainable. CONCLUSIONS This study showed that PEEK has good cytocompatibility with stable and sustainable antibacterial properties under near-ultraviolet. It provides a new idea to solve the non-antibacterial property of PEEK, and also provides a theoretical basis for its further application in dentistry.
Collapse
Affiliation(s)
- Chongxing Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Zhuo Huang
- Department of Stomatology, Shaoxing Hospital of Traditional Chinese Medicine, Shaoxing TCM Hospital Affiliated to Zhejiang Chinese Medical University, Shaoxing 312000, China
| | - Jinlei Zhu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Xiangzhi Liu
- Clinical medical college of Tianjin medical university, Tianjin 300010, China
| | - Bingbing Zhu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Dongyang Zheng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Bingqian Yang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Ran Tao
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Chenxi Cai
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Xiao Chen
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Jinsong Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China.
| | - Zhennan Deng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China.
| |
Collapse
|
17
|
Zol SM, Alauddin MS, Said Z, Mohd Ghazali MI, Hao-Ern L, Mohd Farid DA, Zahari NAH, Al-Khadim AHA, Abdul Aziz AH. Description of Poly(aryl-ether-ketone) Materials (PAEKs), Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) for Application as a Dental Material: A Materials Science Review. Polymers (Basel) 2023; 15:polym15092170. [PMID: 37177316 PMCID: PMC10180673 DOI: 10.3390/polym15092170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/17/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
Poly(aryl-ether-ketone) materials (PAEKs), a class of high-performance polymers comprised of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK), have attracted interest in standard dental procedures due to their inherent characteristics in terms of mechanical and biological properties. Polyetheretherketone (PEEK) is a restorative dental material widely used for prosthetic frameworks due to its superior physical, mechanical, aesthetic, and handling features. Meanwhile, polyetherketoneketone (PEKK) is a semi-crystalline thermoplastic embraced in the additive manufacturing market. In the present review study, a new way to fabricate high-performance polymers, particularly PEEK and PEKK, is demonstrated using additive manufacturing digital dental technology, or 3-dimensional (3D) printing. The focus in this literature review will encompass an investigation of the chemical, mechanical, and biological properties of HPPs, particularly PEEK and PEKK, along with their application particularly in dentistry. High-performance polymers have gained popularity in denture prosthesis in advance dentistry due to their flexibility in terms of manufacturing and the growing interest in utilizing additive manufacturing in denture fabrication. Further, this review also explores the literature regarding the properties of high-performance polymers (HPP) compared to previous reported polymers in terms of the dental material along with the current advancement of the digital designing and manufacturing.
Collapse
Affiliation(s)
- Syazwani Mohamad Zol
- Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Muhammad Syafiq Alauddin
- Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Zulfahmi Said
- Department of Basic Sciences and Oral Biology, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Mohd Ifwat Mohd Ghazali
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Lee Hao-Ern
- Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | | | | | - Aws Hashim Ali Al-Khadim
- Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| | - Azrul Hafiz Abdul Aziz
- Department of Paediatrics Dentistry and Orthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia (USIM), Kuala Lumpur 55100, Malaysia
| |
Collapse
|
18
|
Cheng KJ, Shi ZY, Wang R, Jiang XF, Xiao F, Liu YF. 3D printed PEKK bone analogs with internal porosity and surface modification for mandibular reconstruction: An in vivo rabbit model study. BIOMATERIALS ADVANCES 2023; 151:213455. [PMID: 37148594 DOI: 10.1016/j.bioadv.2023.213455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 04/10/2023] [Accepted: 04/28/2023] [Indexed: 05/08/2023]
Abstract
Polyetheretherketone (PEEK) and its derivative polyetherketoneketone (PEKK) have been used as implant materials for spinal fusing and enjoyed their success for many years because of their mechanical properties similar to bone and their chemical inertness. The osseointegration of PEEKs is datable. Our strategy was to use custom-designed and 3D printed bone analogs with an optimized structure design and a modified PEKK surface to augment bone regeneration for mandibular reconstruction. Those bone analogs had internal porosities and a bioactive titanium oxide surface coating to promote osseointegration between native bone and PEKK analogs. Our workflow was 3D modeling, bone analog designing, structural optimization, mechanical analysis via finite element modeling, 3D printing of bone analogs and subsequently, an in vivo rabbit model study on mandibular reconstruction and histology evaluation. Our results showed the finite element analysis validated that the porous PEKK analogs provided a mechanical-sound structure for functional loadings. The bone analogs offered a perfect replacement for segmented bones in the terms of shape, form and volume for surgical reconstruction. The in vivo results showed that bioactive titanium oxide coating enhanced new bone in-growth into the porous PEKK analogs. We have validated our new approach in surgical mandibular reconstruction and we believe our strategy has a significant potential to improve mechanical and biological outcomes for patients who require mandibular reconstruction procedures.
Collapse
Affiliation(s)
- Kang-Jie Cheng
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; Collaborative Innovation Center of High-end Laser Manufacturing Equipment (National "2011 Plan"), Zhejiang University of Technology, Hangzhou 310023, China
| | - Zhen-Yu Shi
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; Collaborative Innovation Center of High-end Laser Manufacturing Equipment (National "2011 Plan"), Zhejiang University of Technology, Hangzhou 310023, China
| | - Russell Wang
- Department of Comprehensive Care, Case Western Reserve University School of Dental Medicine, Cleveland, OH 44106-4905, USA
| | - Xian-Feng Jiang
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China
| | - Fan Xiao
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; Collaborative Innovation Center of High-end Laser Manufacturing Equipment (National "2011 Plan"), Zhejiang University of Technology, Hangzhou 310023, China
| | - Yun-Feng Liu
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China; Collaborative Innovation Center of High-end Laser Manufacturing Equipment (National "2011 Plan"), Zhejiang University of Technology, Hangzhou 310023, China.
| |
Collapse
|
19
|
Surface Treatments of PEEK for Osseointegration to Bone. Biomolecules 2023; 13:biom13030464. [PMID: 36979399 PMCID: PMC10046336 DOI: 10.3390/biom13030464] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/24/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Polymers, in general, and Poly (Ether-Ether-Ketone) (PEEK) have emerged as potential alternatives to conventional osseous implant biomaterials. Due to its distinct advantages over metallic implants, PEEK has been gaining increasing attention as a prime candidate for orthopaedic and dental implants. However, PEEK has a highly hydrophobic and bioinert surface that attenuates the differentiation and proliferation of osteoblasts and leads to implant failure. Several improvements have been made to the osseointegration potential of PEEK, which can be classified into three main categories: (1) surface functionalization with bioactive agents by physical or chemical means; (2) incorporation of bioactive materials either as surface coatings or as composites; and (3) construction of three-dimensionally porous structures on its surfaces. The physical treatments, such as plasma treatments of various elements, accelerated neutron beams, or conventional techniques like sandblasting and laser or ultraviolet radiation, change the micro-geometry of the implant surface. The chemical treatments change the surface composition of PEEK and should be titrated at the time of exposure. The implant surface can be incorporated with a bioactive material that should be selected following the desired use, loading condition, and antimicrobial load around the implant. For optimal results, a combination of the methods above is utilized to compensate for the limitations of individual methods. This review summarizes these methods and their combinations for optimizing the surface of PEEK for utilization as an implanted biomaterial.
Collapse
|
20
|
Qiu P, Wang P, Liu M, Dai T, Zheng M, Feng L. Biocompatibility and osteoinductive ability of casein phosphopeptide modified polyetheretherketone. Front Bioeng Biotechnol 2023; 11:1100238. [PMID: 36860888 PMCID: PMC9969344 DOI: 10.3389/fbioe.2023.1100238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/30/2023] [Indexed: 02/10/2023] Open
Abstract
Polyetheretherketone (PEEK) is a potential implant material for dental application due to its excellent mechanical properties. However, its biological inertness and poor osteoinductive ability limited its clinical application. Based on a lay-by-layer self-assembly technique, here we incorporated casein phosphopeptide (CPP) onto PEEK surface by a simple two-step strategy to address the poor osteoinductive ability of PEEK implants. In this study, the PEEK specimens were positively charged by 3-ammoniumpropyltriethoxysilane (APTES) modification, then the CPP was adsorbed onto the positively charged PEEK surface electrostatically to obtain CPP-modified PEEK (PEEK-CPP) specimens. The surface characterization, layer degradation, biocompatibility and osteoinductive ability of the PEEK-CPP specimens were studied in vitro. After CPP modification, the PEEK-CPP specimens had a porous and hydrophilic surface and presented enhanced cell adhesion, proliferation, and osteogenic differentiation of MC3T3-E1 cells. These findings indicated that CPP modification could significantly improve the biocompatibility and osteoinductive ability of PEEK-CPP implants in vitro. In a word, CPP modification is a promising strategy for the PEEK implants to achieve osseointegration.
Collapse
Affiliation(s)
- Peng Qiu
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China,*Correspondence: Peng Qiu, ; Pin Wang,
| | - Pin Wang
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China,*Correspondence: Peng Qiu, ; Pin Wang,
| | - Min Liu
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| | - Tao Dai
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| | - Min Zheng
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| | - Le Feng
- The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China,Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, Luzhou, Sichuan, China,Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| |
Collapse
|
21
|
Synergistic effect of sulfonation followed by precipitation of amorphous calcium phosphate on the bone-bonding strength of carbon fiber reinforced polyetheretherketone. Sci Rep 2023; 13:1443. [PMID: 36697480 PMCID: PMC9876887 DOI: 10.1038/s41598-023-28701-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 01/23/2023] [Indexed: 01/26/2023] Open
Abstract
Sulfonation and applications of amorphous calcium phosphate are known to make polyetheretherketone (PEEK) bioactive. Sulfonation followed by precipitation of amorphous calcium phosphate (AN-treatment) may provide PEEK with further bone-bonding strength. Herein, we prepared a carbon-fiber-reinforced PEEK (CPEEK) with similar tensile strength to cortical bone and a CPEEK subjected to AN-treatment (CPEEK-AN). The effect of AN-treatment on the bone-bonding strength generated at the interface between the rabbit's tibia and a base material was investigated using a detaching test at two time-points (4 and 8 weeks). At 4 weeks, the strength of CPEEK-AN was significantly higher than that of CPEEK due to the direct bonding between the interfaces. Between 4 and 8 weeks, the different bone forming processes showed that, with CPEEK-AN, bone consolidation was achieved, thus improving bone-bonding strength. In contrast, with CPEEK, a new bone was absorbed mainly on the interface, leading to poor strength. These observations were supported by an in vitro study, which showed that pre-osteoblast on CPEEK-AN caused earlier maturation and mineralization of the extracellular matrix than on CPEEK. Consequently, AN-treatment, comprising a combination of two efficient treatments, generated a synergetic effect on the bonding strength of CPEEK.
Collapse
|
22
|
Padinjarathil H, Mudradi S, Balasubramanian R, Drago C, Dattilo S, Kothurkar NK, Ramani P. Design of an Antibiotic-Releasing Polymer: Physicochemical Characterization and Drug Release Patterns. MEMBRANES 2023; 13:membranes13010102. [PMID: 36676910 PMCID: PMC9866011 DOI: 10.3390/membranes13010102] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/23/2022] [Accepted: 12/29/2022] [Indexed: 06/01/2023]
Abstract
Conventional drug delivery has its share of shortcomings, especially its rapid drug release with a relatively short duration of therapeutic drug concentrations, even in topical applications. Prolonged drug release can be effectively achieved by modifying the carrier in a drug delivery system. Among the several candidates for carriers studied over the years, poly (ether ether ketone), a biocompatible thermoplastic, was chosen as a suitable carrier. Its inherent hydrophobicity was overcome by controlled sulfonation, which introduced polar sulfonate groups onto the polymer backbone. Optimization of the sulfonation process was completed by the variation of the duration, temperature of the sulfonation, and concentration of sulfuric acid. The sulfonation was confirmed by EDS and the degree of sulfonation was determined by an NMR analysis (61.6% and 98.9%). Various physical properties such as morphology, mechanical strength, and thermal stability were studied using scanning electron microscopy, tensile testing, and thermogravimetric analysis. Cytotoxicity tests were performed on the SPEEK samples to study the variation in biocompatibility against a Vero cell line. The drug release kinetics of ciprofloxacin (CP) and nalidixic acid sodium salt (NA)-loaded membranes were studied in deionized water as well as SBF and compared against the absorbance of standardized solutions of the drug. The data were then used to determine the diffusion, distribution, and permeability coefficients. Various mathematical models were used to fit the obtained data to establish the order and mechanism of drug release. Studies revealed that drug release occurs by diffusion and follows zero-order kinetics.
Collapse
Affiliation(s)
- Himabindu Padinjarathil
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
- Department of Chemical Engineering and Materials Science, School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Srikrishna Mudradi
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Rajalakshmi Balasubramanian
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Carmelo Drago
- Institute of Biomolecular Chemistry, CNR, via Paolo Gaifami 18, 95126 Catania, Italy
| | - Sandro Dattilo
- Institute for Polymer, Composite and Biomaterials, CNR, via Paolo Gaifami 18, 95126 Catania, Italy
| | - Nikhil K. Kothurkar
- Department of Chemical Engineering and Materials Science, School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
- Center of Excellence in Advanced Materials & Green Technologies (CoE–AMGT), Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| | - Prasanna Ramani
- Dhanvanthri Laboratory, Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
- Center of Excellence in Advanced Materials & Green Technologies (CoE–AMGT), Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Coimbatore 641112, India
| |
Collapse
|
23
|
dos Santos FSF, Rodrigues JFB, da Silva MC, Barreto MEV, da Silva HN, de Lima Silva SM, Fook MVL. Use of Piranha Solution as An Alternative Route to Promote Bioactivation of PEEK Surface with Low Functionalization Times. MOLECULES (BASEL, SWITZERLAND) 2022; 28:molecules28010074. [PMID: 36615270 PMCID: PMC9822504 DOI: 10.3390/molecules28010074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 12/24/2022]
Abstract
This study aimed to achieve bioactivity on the PEEK surface using piranha solution through a lower functionalization time. For this purpose, the functionalization occurred with piranha solution and 98% sulfuric acid in the proportions of 1:2, 1:1, and 2:1 at periods of 30, 60, and 90 s. The samples treated for longer times at higher concentrations registered the characteristic spectroscopy band associated with sulfonation. Additionally, both chemical treatments allowed the opening of the aromatic ring, increasing the number of functional groups available and making the surface more hydrophilic. The piranha solution treatments with higher concentrations and longer times promoted greater heterogeneity in the surface pores, which affected the roughness of untreated PEEK. Furthermore, the treatments induced calcium deposition on the surface during immersion in SBF fluid. In conclusion, the proposed chemical modifications using sulfuric acid SPEEK 90 and, especially, the piranha solution PEEK-PS 2:1-90, were demonstrated to be promising in promoting the rapid bioactivation of PEEK-based implants.
Collapse
|
24
|
Pidhatika B, Widyaya VT, Nalam PC, Swasono YA, Ardhani R. Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry. Polymers (Basel) 2022; 14:polym14245526. [PMID: 36559893 PMCID: PMC9787615 DOI: 10.3390/polym14245526] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 12/23/2022] Open
Abstract
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium-the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Collapse
Affiliation(s)
- Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
- Collaborative Research Center for Biomedical Scaffolds, National Research and Innovation Agency of the Republic Indonesia and Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
| | - Vania Tanda Widyaya
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Prathima C. Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY 14260-1900, USA
| | - Yogi Angga Swasono
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
- Correspondence:
| |
Collapse
|
25
|
Qiu P, Feng L, Fu Q, Dai T, Liu M, Wang P, Lan Y. Dual-Functional Polyetheretherketone Surface with an Enhanced Osteogenic Capability and an Antibacterial Adhesion Property In Vitro by Chitosan Modification. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:14712-14724. [PMID: 36420594 DOI: 10.1021/acs.langmuir.2c02267] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
A chitosan layer was covalently bonded to a polyetheretherketone (PEEK) surface using a simple facile self-assembly method to address inadequate biological activity and infection around the implant. The surface characterization, layer degradation, biological activity, and antibacterial adhesion properties of chitosan-modified PEEK (PEEK-CS) were studied. Through chitosan grafting, the surface morphology changed, the surface roughness increased, and the contact angle decreased significantly. PEEK-CS boosted cell adhesion, proliferation, increased alkaline phosphate activity, extracellular matrix mineralization, and expression of osteogenic genes. PEEK-CS demonstrated less adhesion to Porphyromonas gingivalis as well as less bacterial adhesion to P. gingivalis and Streptococcus mutans. According to our findings, chitosan modification significantly improved the osteogenic ability and antibacterial adhesion of PEEK in vitro.
Collapse
Affiliation(s)
- Peng Qiu
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Le Feng
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Qilin Fu
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Tao Dai
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Min Liu
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Pin Wang
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| | - Yuyan Lan
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou646000, China
- Luzhou Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Luzhou646000, China
| |
Collapse
|
26
|
Wang B, Huang M, Dang P, Xie J, Zhang X, Yan X. PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers (Basel) 2022; 14:polym14122323. [PMID: 35745900 PMCID: PMC9228596 DOI: 10.3390/polym14122323] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 01/27/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely applied in fixed dental prostheses, comprising crowns, fixed partial dentures, and post-and-core. PEEK’s excellent mechanical properties facilitate better stress distribution than conventional materials, protecting the abutment teeth. However, the stiffness of PEEK is not sufficient, which can be improved via fiber reinforcement. PEEK is biocompatible. It is nonmutagenic, noncytotoxic, and nonallergenic. However, the chemical stability of PEEK is a double-edged sword. On the one hand, PEEK is nondegradable and intraoral corrosion is minimized. On the other hand, the inert surface makes adhesive bonding difficult. Numerous strategies for improving the adhesive properties of PEEK have been explored, including acid etching, plasma treatment, airborne particle abrasion, laser treatment, and adhesive systems.
Collapse
Affiliation(s)
- Biyao Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Minghao Huang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
| | - Pengrui Dang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Jiahui Xie
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Xinwen Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| | - Xu Yan
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| |
Collapse
|
27
|
Immobilization of Collagen on the Surface of a PEEK Implant with Monolayer Nanopores. Polymers (Basel) 2022; 14:polym14091633. [PMID: 35566803 PMCID: PMC9102333 DOI: 10.3390/polym14091633] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 04/06/2022] [Accepted: 04/11/2022] [Indexed: 01/02/2023] Open
Abstract
Polyetheretherketone (PEEK) is the only polymer material that can replace titanium implants in the field of orthopedics. This is because the mechanical properties of PEEK are similar to those of bone, and PEEK has natural radiolucency, chemical stability, and sterilization resistance. Despite these advantages, PEEK has a disadvantage—that it is bio-inert. Therefore, many studies have attempted to change the bio-inertness of PEEK into bioactivity. Among them, a method of forming pores by acid treatment is attracting attention. In this study, an attempt was made to form pores on the surface of PEEK implant using a mixed acid of sulfuric acid and nitric acid. As a result, it was found that the condition when the PEEK surface is in contact with the acid is very important. That is, it was possible to form single-layered nanopores on the surface by contacting PEEK with a mixed acid under ultrasound. Additionally, by immobilizing type I collagen on the porous PEEK surface through dopamine coating, it was possible to obtain collagen-immobilized porous PEEK (P-PEEK-Col) with high compatibility with osteoblasts. This P-PEEK-Col has high potential for use as a bone substitute that promotes bone formation.
Collapse
|
28
|
Chen J, Cao G, Li L, Cai Q, Dunne N, Li X. Modification of polyether ether ketone for the repairing of bone defects. Biomed Mater 2022; 17. [PMID: 35395651 DOI: 10.1088/1748-605x/ac65cd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 04/08/2022] [Indexed: 11/12/2022]
Abstract
Bone damage as a consequence of disease or trauma is a common global occurrence. For bone damage treatment - bone implant materials are necessary across three classifications of surgical intervention (i.e. fixation, repair, and replacement). Many types of bone implant materials have been developed to meet the requirements of bone repair. Among them, polyether ether ketone (PEEK) has been considered as one of the next generation of bone implant materials, owing to its advantages related to good biocompatibility, chemical stability, X-ray permeability, elastic modulus comparable to natural bone, as well as the ease of processing and modification. However, as PEEK is a naturally bioinert material, some modification is needed to improve its integration with adjacent bones after implantation. Therefore, it has become a very hot topic of biomaterials research and various strategies for the modification of PEEK including blending, 3D printing, coating, chemical modification and the introduction of bioactive and/or antibacterial substances have been proposed. In this systematic review, the recent advances in modification of PEEK and its application prospect as bone implants are summarized, and the remaining challenges are also discussed.
Collapse
Affiliation(s)
- Junfeng Chen
- Beihang University, 37 Xueyuan Rd, Haidian District, Beijing, Beijing, 100083, CHINA
| | - Guangxiu Cao
- Beihang University, 37 Xueyuan Rd, Haidian District, Beijing, Beijing, 100083, CHINA
| | - Linhao Li
- Beihang University, 37 Xueyuan Rd, Haidian District, Beijing, 100083, CHINA
| | - Qiang Cai
- Tsinghua University Department of Materials Science and Engineering, 30 shuangqing Rd, Haidian District, Beijing, Beijing, 100084, CHINA
| | - Nicholas Dunne
- School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9, Dublin, D09, IRELAND
| | - Xiaoming Li
- Biological Science and Medical Engineering, Beihang University, 37 Xueyuan Rd, Haidian District, Beijing, Beijing, 100083, CHINA
| |
Collapse
|
29
|
Yu D, Lei X, Zhu H. Modification of polyetheretherketone (PEEK) physical features to improve osteointegration. J Zhejiang Univ Sci B 2022; 23:189-203. [PMID: 35261215 DOI: 10.1631/jzus.b2100622] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Polyetheretherketone (PEEK) has been widely applied in orthopedics because of its excellent mechanical properties, radiolucency, and biocompatibility. However, the bioinertness and poor osteointegration of PEEK have greatly limited its further application. Growing evidence proves that physical factors of implants, including their architecture, surface morphology, stiffness, and mechanical stimulation, matter as much as the composition of their surface chemistry. This review focuses on the multiple strategies for the physical modification of PEEK implants through adjusting their architecture, surface morphology, and stiffness. Many research findings show that transforming the architecture and incorporating reinforcing fillers into PEEK can affect both its mechanical strength and cellular responses. Modified PEEK surfaces at the macro scale and micro/nano scale have positive effects on cell-substrate interactions. More investigations are necessary to reach consensus on the optimal design of PEEK implants and to explore the efficiency of various functional implant surfaces. Soft-tissue integration has been ignored, though evidence shows that physical modifications also improve the adhesion of soft tissue. In the future, ideal PEEK implants should have a desirable topological structure with better surface hydrophilicity and optimum surface chemistry.
Collapse
Affiliation(s)
- Dan Yu
- Department of Oral and Maxillofacial Surgery, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China
| | - Xiaoyue Lei
- Department of Stomatology, Zhejiang University School of Medicine, Hangzhou 310058, China
| | - Huiyong Zhu
- Department of Oral and Maxillofacial Surgery, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China.
| |
Collapse
|
30
|
Fekete S, DeLano M, Harrison AB, Shiner SJ, Belanger JL, Wyndham KD, Lauber MA. Size Exclusion and Ion Exchange Chromatographic Hardware Modified with a Hydrophilic Hybrid Surface. Anal Chem 2022; 94:3360-3367. [PMID: 35143179 DOI: 10.1021/acs.analchem.1c05466] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Certain biomolecules have proven to be difficult to analyze by liquid chromatography (LC), especially under certain chromatographic conditions. The separation of proteins in aqueous mobile phases is one such example because there is the potential for both hydrophobic and ionic secondary interactions to occur with chromatographic hardware to the detriment of peak recovery, peak shape, and the overall sensitivity of the LC analysis. To decrease non-specific adsorption and undesired secondary interactions between column hardware and biomolecules, we have developed and applied a new hydrophilically modified hybrid surface (h-HST) for size exclusion chromatography (SEC) and anion exchange (AEX) separations of proteins and nucleic acids. This surface incorporates additional oxygen and carbon atoms onto an ethylene bridge hybrid siloxane polymer. As a result, it exhibits reduced electrostatic properties and hydrophilicity that facilitates challenging aqueous separations. Flow injection tests with a phosphate buffer showed superior protein recovery from an h-HST frit when compared to unmodified ethylene-bridged hybrid HST, titanium, stainless steel, and PEEK frits. When applied to SEC of rituximab, ramucirumab, and trastuzumab emtansine with a 50 mM ammonium acetate buffer, this new hydrophilic chromatographic hardware yielded improved monomer and aggregate recovery, higher plate numbers, and more symmetrical peaks. AEX columns also benefited from h-HST hardware. An acidic mAb (eculizumab) showed improved recovery, more stable retention, and a sharper peak when eluted from an h-HST versus SS column. Moreover, AEX separations of intact mRNA samples (Cas9 and EPO mRNA) were improved, where it was seen that h-HST column hardware provided higher sensitivity and more repeatable peak areas from injection to injection. As such, there is significant potential in the use of h-HST chromatographic hardware to facilitate more robust and more sensitive analyses for a multitude of challenging separations and analytes.
Collapse
Affiliation(s)
- Szabolcs Fekete
- Waters Corporation, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Stephen J Shiner
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Kevin D Wyndham
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| |
Collapse
|
31
|
Immunomodulatory Properties and Osteogenic Activity of Polyetheretherketone Coated with Titanate Nanonetwork Structures. Int J Mol Sci 2022; 23:ijms23020612. [PMID: 35054795 PMCID: PMC8775651 DOI: 10.3390/ijms23020612] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 12/31/2021] [Accepted: 01/01/2022] [Indexed: 12/23/2022] Open
Abstract
Polyetheretherketone (PEEK) is a potential substitute for conventional metallic biomedical implants owing to its superior mechanical and chemical properties, as well as biocompatibility. However, its inherent bio-inertness and poor osseointegration limit its use in clinical applications. Herein, thin titanium films were deposited on the PEEK substrate by plasma sputtering, and porous nanonetwork structures were incorporated on the PEEK surface by alkali treatment (PEEK-TNS). Changes in the physical and chemical characteristics of the PEEK surface were analyzed to establish the interactions with cell behaviors. The osteoimmunomodulatory properties were evaluated using macrophage cells and osteoblast lineage cells. The functionalized nanostructured surface of PEEK-TNS effectively promoted initial cell adhesion and proliferation, suppressed inflammatory responses, and induced macrophages to anti-inflammatory M2 polarization. Compared with PEEK, PEEK-TNS provided a more beneficial osteoimmune environment, including increased levels of osteogenic, angiogenic, and fibrogenic gene expression, and balanced osteoclast activities. Furthermore, the crosstalk between macrophages and osteoblast cells showed that PEEK-TNS could provide favorable osteoimmunodulatory environment for bone regeneration. PEEK-TNS exhibited high osteogenic activity, as indicated by alkaline phosphatase activity, osteogenic factor production, and the osteogenesis/osteoclastogenesis-related gene expression of osteoblasts. The study establishes that the fabrication of titanate nanonetwork structures on PEEK surfaces could extract an adequate immune response and favorable osteogenesis for functional bone regeneration. Furthermore, it indicates the potential of PEEK-TNS in implant applications.
Collapse
|
32
|
Zhao X, Liu Y, Coates P, Caton-Rose F, Ye L. Triple-shape memory effect of long-chain branched Poly(lactic acid)-b-poly(lactide-co-caprolactone) and its controllable shape recovery as self-fastening smart bone fixture. POLYMER 2022. [DOI: 10.1016/j.polymer.2021.124421] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
33
|
dos Santos FSF, Vieira M, da Silva HN, Tomás H, Fook MVL. Surface Bioactivation of Polyether Ether Ketone (PEEK) by Sulfuric Acid and Piranha Solution: Influence of the Modification Route in Capacity for Inducing Cell Growth. Biomolecules 2021; 11:biom11091260. [PMID: 34572473 PMCID: PMC8465912 DOI: 10.3390/biom11091260] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 12/26/2020] [Accepted: 12/27/2020] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to promote bioactivity of the PEEK surface using sulfuric acid and piranha solution. PEEK was functionalized by a sulfuric acid treatment for 90 s and by piranha solution for 60 and 90 s. Chemical modification of the PEEK surface was evaluated by infrared spectroscopy, contact angle analysis, cytotoxicity, cell adhesion and proliferation. The spectroscopy characteristic band associated with sulfonation was observed in all treated samples. PEEK with piranha solution 60 s showed an increase in the intensity of the bands, which was even more significant for the longer treatment (90 s). The introduction of the sulfonic acid functional group reduced the contact angle. In cytotoxicity assays, for all treatments, the number of viable cells was higher when compared to those of untreated PEEK. PEEK treated with sulfuric acid and piranha solution for 60 s were the treatments that showed the highest percentage of cell viability with no statistically significant differences between them. The modified surfaces had a greater capacity for inducing cell growth, indicative of effective cell adhesion and proliferation. The proposed chemical modifications are promising for the functionalization of PEEK-based implants, as they were effective in promoting bioactivation of the PEEK surface and in stimulating cell growth and proliferation.
Collapse
Affiliation(s)
- Flavia Suzany Ferreira dos Santos
- Departament of Materials Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil; (F.S.F.d.S.); (H.N.d.S.)
| | - Mariana Vieira
- CQM—Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal; (M.V.); (H.T.)
| | - Henrique Nunes da Silva
- Departament of Materials Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil; (F.S.F.d.S.); (H.N.d.S.)
| | - Helena Tomás
- CQM—Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal; (M.V.); (H.T.)
| | - Marcus Vinícius Lia Fook
- Departament of Materials Engineering, Federal University of Campina Grande, Campina Grande 58429-900, PB, Brazil; (F.S.F.d.S.); (H.N.d.S.)
- Correspondence: ; Tel.: +55-8321011841
| |
Collapse
|
34
|
Frankenberger T, Graw CL, Engel N, Gerber T, Frerich B, Dau M. Sustainable Surface Modification of Polyetheretherketone (PEEK) Implants by Hydroxyapatite/Silica Coating-An In Vivo Animal Study. MATERIALS 2021; 14:ma14164589. [PMID: 34443112 PMCID: PMC8398357 DOI: 10.3390/ma14164589] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/06/2021] [Accepted: 08/12/2021] [Indexed: 12/27/2022]
Abstract
Polyetheretherketone (PEEK) has the potential to overcome some of the disadvantages of titanium interbody implants in anterior cervical and discectomy and fusion (ACDF). However, PEEK shows an inferior biological behavior regarding osseointegration and bioactivity. Therefore, the aim of the study was to create a bioactive surface coating on PEEK implants with a unique nanopore structure enabling the generation of a long-lasting interfacial composite layer between coating material and implant. Seventy-two PEEK implants-each thirty-six pure PEEK implants (PI) and thirty-six PEEK implants with a sprayed coating consisting of nanocrystalline hydroxyapatite (ncHA) embedded in a silica matrix and interfacial composite layer (SPI)-were inserted in the femoral condyles of adult rats using a split-side model. After 2, 4 and 8 weeks, the femur bones were harvested. Half of the femur bones were used in histological and histomorphometrical analyses. Additionally, pull-out tests were performed in the second half. Postoperative healing was uneventful for all animals, and no postoperative complications were observed. Considerable crestal and medullary bone remodeling could be found around all implants, with faster bone formation around the SPI and fewer regions with fibrous tissue barriers between implant and bone. Histomorphometrical analyses showed a higher bone to implant contact (BIC) in SPI after 4 and 8 weeks (p < 0.05). Pull-out tests revealed higher pull-out forces in SPI at all time points (p < 0.01). The presented findings demonstrate that a combination of a bioactive coating and the permanent chemical and structural modified interfacial composite layer can improve bone formation at the implant surface by creating a sustainable bone-implant interface. This might be a promising way to overcome the bioinert surface property of PEEK-based implants.
Collapse
Affiliation(s)
- Thomas Frankenberger
- Institute of Physics, Rostock University, 18057 Rostock, Germany; (T.F.); (T.G.)
| | - Constantin Leon Graw
- Department of Oral, Maxillofacial and Plastic Surgery, Rostock University Medical Center, 18057 Rostock, Germany; (C.L.G.); (N.E.); (B.F.)
| | - Nadja Engel
- Department of Oral, Maxillofacial and Plastic Surgery, Rostock University Medical Center, 18057 Rostock, Germany; (C.L.G.); (N.E.); (B.F.)
| | - Thomas Gerber
- Institute of Physics, Rostock University, 18057 Rostock, Germany; (T.F.); (T.G.)
| | - Bernhard Frerich
- Department of Oral, Maxillofacial and Plastic Surgery, Rostock University Medical Center, 18057 Rostock, Germany; (C.L.G.); (N.E.); (B.F.)
| | - Michael Dau
- Department of Oral, Maxillofacial and Plastic Surgery, Rostock University Medical Center, 18057 Rostock, Germany; (C.L.G.); (N.E.); (B.F.)
- Correspondence: ; Tel.: +49-381-494-6688
| |
Collapse
|
35
|
Effect of Extreme Ultraviolet (EUV) Radiation and EUV Induced, N 2 and O 2 Based Plasmas on a PEEK Surface's Physico-Chemical Properties and MG63 Cell Adhesion. Int J Mol Sci 2021; 22:ijms22168455. [PMID: 34445159 PMCID: PMC8395134 DOI: 10.3390/ijms22168455] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 07/28/2021] [Accepted: 08/03/2021] [Indexed: 11/17/2022] Open
Abstract
Polyetheretherketone (PEEK), due to its excellent mechanical and physico-chemical parameters, is an attractive substitute for hard tissues in orthopedic applications. However, PEEK is hydrophobic and lacks surface-active functional groups promoting cell adhesion. Therefore, the PEEK surface must be modified in order to improve its cytocompatibility. In this work, extreme ultraviolet (EUV) radiation and two low-temperature, EUV induced, oxygen and nitrogen plasmas were used for surface modification of polyetheretherketone. Polymer samples were irradiated with 100, 150, and 200 pulses at a 10 Hz repetition rate. The physical and chemical properties of EUV and plasma modified PEEK surfaces, such as changes of the surface topography, chemical composition, and wettability, were examined using atomic force microscopy (AFM), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and goniometry. The human osteoblast-like MG63 cells were used for the analysis of cell viability and cell adhesion on all modified PEEK surfaces. EUV radiation and two types of plasma treatment led to significant changes in surface topography of PEEK, increasing surface roughness and formation of conical structures. Additionally, significant changes in the chemical composition were found and were manifested with the appearance of new functional groups, incorporation of nitrogen atoms up to ~12.3 at.% (when modified in the presence of nitrogen), and doubling the oxygen content up to ~25.7 at.% (when modified in the presence of oxygen), compared to non-modified PEEK. All chemically and physically changed surfaces demonstrated cyto-compatible and non-cytotoxic properties, an enhancement of MG63 cell adhesion was also observed.
Collapse
|
36
|
Addai Asante N, Wang Y, Bakhet S, Kareem S, Owusu KA, Hu Y, Appiah M. Ambient temperature sulfonated carbon fiber reinforced PEEK with hydroxyapatite and reduced graphene oxide hydroxyapatite composite coating. J Biomed Mater Res B Appl Biomater 2021; 109:2174-2183. [PMID: 34002921 DOI: 10.1002/jbm.b.34865] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/26/2021] [Accepted: 05/03/2021] [Indexed: 11/11/2022]
Abstract
30% carbon fiber reinforced polyetheretherketone (CFR-PEEK) has in recent times, become significant in the orthopedic industry because its elastic modulus can be engineered to match that of the human bone. But it is bioinert and does not integrate well with the immediate bone tissue environment. In this study, a combined surface modification technique involving ambient temperature sulfonation and surface coating of (hydroxyapatite (HA), 5%reduced graphene oxide hydroxyapatite(5%RGO/HA) and 10%reduced graphene oxide hydroxyapatite(10%RGO/HA) composites) on 30%CFR-PEEK was achieved with an appropriate temperature treatment at 345°C in nitrogen. The coatings adhered unto the surface of S30%CFR-PEEK with an improved hydrophilicity and bioactivity. With the sample S30%CFR-PEEK+HA, having the highest enhanced hydrophilicity from 112.5 ± 2.5° to 20 ± 2° and bioactivity. An improvement in hydrophilicity and bioactivity depicts a change in surface chemistry which will have a positive impact in the interaction of the materials surface with immediate bone environment for a successful application in the orthopedic industry.
Collapse
Affiliation(s)
- Naomi Addai Asante
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Youfa Wang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Shahd Bakhet
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Shefiu Kareem
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Kwadwo Asare Owusu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Yuandi Hu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| | - Millicent Appiah
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, China
| |
Collapse
|
37
|
Hossain MM, Lokasani VR. IMPROVING THE HYDROPHOBICITY OF POLYMERS THROUGH SURFACE TEXTURING. CONFERENCE PROCEEDINGS. SOCIETY OF PLASTICS ENGINEERS. TECHNICAL CONFERENCE 2021; 2021:268-274. [PMID: 35529586 PMCID: PMC9075775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Introduction of surface textures has long been used to improve the hydrophobicity of solid materials. This study focusses on understanding the effects of various micro-texture geometries on the hydrophobicity of textured polymer surfaces. Square pillar, cylindrical, hemispherical and conical surface features, both protrusion and cavity, are considered in this study for two polymers. Employing the well-known models, the study shows that introducing textures on polymer surfaces generally increases the contact angle and, therefore, improves the hydrophobicity of polymers. The effect of surface texture on hydrophobicity significantly varies with texture geometry and dimension. The study provides useful guidelines for improving hydrophobicity of polymers by introducing textures on the surface.
Collapse
Affiliation(s)
- Mohammad Motaher Hossain
- Department of Mechanical & Industrial Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA
| | - Vinay Reddy Lokasani
- Department of Mechanical & Industrial Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA
| |
Collapse
|
38
|
Pang Z, Pan Z, Ma M, Xu Z, Mei S, Jiang Z, Yin F. Nanostructured Coating of Non-Crystalline Tantalum Pentoxide on Polyetheretherketone Enhances RBMS Cells/HGE Cells Adhesion. Int J Nanomedicine 2021; 16:725-740. [PMID: 33542627 PMCID: PMC7853447 DOI: 10.2147/ijn.s286643] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 12/23/2020] [Indexed: 01/15/2023] Open
Abstract
PURPOSE As a dental material, polyetheretherketone (PEEK) is bioinert that does not induce cellular response and bone/gingival tissues regeneration. This study was to develop bioactive coating on PEEK and investigate the effects of coating on cellular response. MATERIALS AND METHODS Tantalum pentoxide (TP) coating was fabricated on PEEK surface by vacuum evaporation and responses of rat bone marrow mesenchymal stem (RBMS) cells/human gingival epithelial (HGE) were studied. RESULTS A dense coating (around 400 nm in thickness) of TP was closely combined with PEEK (PKTP). Moreover, the coating was non-crystalline TP, which contained many small humps (around 10 nm in size), exhibiting a nanostructured surface. In addition, the roughness, hydrophilicity, surface energy, and protein adsorption of PKTP were remarkably higher than that of PEEK. Furthermore, the responses (adhesion, proliferation, and osteogenic gene expression) of RBMS cells, and responses (adhesion and proliferation) of HGE cells to PKTP were remarkably improved in comparison with PEEK. It could be suggested that the nanostructured coating of TP on PEEK played crucial roles in inducing the responses of RBMS/HGE cells. CONCLUSION PKTP with elevated surface performances and outstanding cytocompatibility might have enormous potential for dental implant application.
Collapse
Affiliation(s)
- Zhiying Pang
- Department of Joint Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai200092, People’s Republic of China
| | - Zhangyi Pan
- Department of Joint Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai200092, People’s Republic of China
| | - Min Ma
- Department of Joint Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai200092, People’s Republic of China
| | - Zhiyan Xu
- Key Laboratory for Ultrafine Materials of Ministry of Education, East China University of Science and Technology, Shanghai200237, People’s Republic of China
| | - Shiqi Mei
- Key Laboratory for Ultrafine Materials of Ministry of Education, East China University of Science and Technology, Shanghai200237, People’s Republic of China
| | - Zengxin Jiang
- Department of Orthopedic Surgery, Zhongshan Hospital, Fudan University, Shanghai200032, People’s Republic of China
| | - Feng Yin
- Department of Joint Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai200092, People’s Republic of China
| |
Collapse
|
39
|
Review on Development and Dental Applications of Polyetheretherketone-Based Biomaterials and Restorations. MATERIALS 2021; 14:ma14020408. [PMID: 33467576 PMCID: PMC7830426 DOI: 10.3390/ma14020408] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/10/2021] [Accepted: 01/12/2021] [Indexed: 12/15/2022]
Abstract
Polyetheretherketone (PEEK) is an important high-performance thermoplastic. Its excellent strength, stiffness, toughness, fatigue resistance, biocompatibility, chemical stability and radiolucency have made PEEK attractive in dental and orthopedic applications. However, PEEK has an inherently hydrophobic and chemically inert surface, which has restricted its widespread use in clinical applications, especially in bonding with dental resin composites. Cutting edge research on novel methods to improve PEEK applications in dentistry, including oral implant, prosthodontics and orthodontics, is reviewed in this article. In addition, this article also discusses innovative surface modifications of PEEK, which are a focus area of active investigations. Furthermore, this article also discusses the necessary future studies and clinical trials for the use of PEEK in the human oral environment to investigate its feasibility and long-term performance.
Collapse
|
40
|
Liu C, Bai J, Wang Y, Chen L, Wang D, Ni S, Liu H. The effects of three cold plasma treatments on the osteogenic activity and antibacterial property of PEEK. Dent Mater 2021; 37:81-93. [DOI: 10.1016/j.dental.2020.10.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 09/11/2020] [Accepted: 10/06/2020] [Indexed: 11/16/2022]
|
41
|
Czwartos J, Budner B, Bartnik A, Wachulak P, Fiedorowicz H, Mierczyk Z. Physico-Chemical Surface Modifications of Polyetheretherketone (PEEK) Using Extreme Ultraviolet (EUV) Radiation and EUV-Induced Nitrogen Plasma. MATERIALS 2020; 13:ma13194466. [PMID: 33050110 PMCID: PMC7579647 DOI: 10.3390/ma13194466] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Revised: 10/04/2020] [Accepted: 10/06/2020] [Indexed: 11/17/2022]
Abstract
In this work, the effect of extreme ultraviolet (EUV) radiation and the combination of EUV radiation and low-temperature nitrogen plasma on the physico-chemical properties of polyetheretherketone (PEEK) surfaces were presented. The laser-plasma EUV source based on a double gas puff target was used in this experiment to irradiate PEEK surfaces with nanosecond pulses of EUV radiation and to produce low-temperature plasma through the photoionization of nitrogen with EUV photons. The changes in surface morphology on irradiated polymer samples were examined using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Chemical changes of the PEEK surfaces were analysed using X-ray photoelectron spectroscopy (XPS). EUV radiation and nitrogen plasma treatment caused significant changes in the topography of modified PEEK’s surfaces and an increase in their average roughness. Strong chemical decomposition, appearance of new functional groups as well as incorporation of nitrogen atoms up to ~17 at.% on the PEEK’s surface were observed.
Collapse
|
42
|
Zhao X, Karthik N, Xiong D, Liu Y. Bio-inspired surface modification of PEEK through the dual cross-linked hydrogel layers. J Mech Behav Biomed Mater 2020; 112:104032. [PMID: 32861065 DOI: 10.1016/j.jmbbm.2020.104032] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 04/04/2020] [Accepted: 08/08/2020] [Indexed: 11/26/2022]
Abstract
The biocompatible high-performance material PEEK (polyetheretherketone) is an attractive implant material, however, its hydrophobicity and high friction coefficients severely hinder its biomedical applications. Thus, it is inferred from the recent advances in surface modification technology, achieving the biomimetic natural joint lubrication systems on PEEK still remains a challenge. In view of the above, herein we proposed a novel two-step strategy to fabricate a "soft (dual cross-linked hydrogel) layer-hard (PEEK) substrate" texture that mimics the structure and function of soft cartilage on the hard basal bone in joints. At first, a layer of acrylic acid-co-acryl amide (AA-AM) hydrogel is anchored to the PEEK substrate through UV-initiated polymerization. In the second step, hydrogel coated PEEK substrate is immersed in ferric nitrate solution to create the secondary cross-linkage between Fe3+ and -COOH groups in the hydrogel. As a result, the consequential top-coat hydrogel layer not only transforms the surface wettability (hydrophobic to hydrophilic) but also provides scratch resistance to the underlying PEEK substrate. The modified specimens display low friction coefficients in water under different load conditions. In addition, the obtained surface exhibits a certain self-repairing ability due to its unique physically reversible network structure. Therefore, this work provides a promising strategy for broadening the use of PEEK in orthopedic implants.
Collapse
Affiliation(s)
- Xiaoduo Zhao
- School of Materials Science and Engineering, Nanjing University of Science and Technology, 210094, Nanjing, China; Jiangsu Key Laboratory of Advanced Micro/Nano Materials and Technology, 210094, Nanjing, China
| | - Namachivayam Karthik
- School of Materials Science and Engineering, Nanjing University of Science and Technology, 210094, Nanjing, China; Jiangsu Key Laboratory of Advanced Micro/Nano Materials and Technology, 210094, Nanjing, China
| | - Dangsheng Xiong
- School of Materials Science and Engineering, Nanjing University of Science and Technology, 210094, Nanjing, China; Jiangsu Key Laboratory of Advanced Micro/Nano Materials and Technology, 210094, Nanjing, China.
| | - Yuntong Liu
- School of Materials Science and Engineering, Nanjing University of Science and Technology, 210094, Nanjing, China; Jiangsu Key Laboratory of Advanced Micro/Nano Materials and Technology, 210094, Nanjing, China
| |
Collapse
|
43
|
Ma R, Wang J, Li C, Ma K, Wei J, Yang P, Guo D, Wang K, Wang W. Effects of different sulfonation times and post-treatment methods on the characterization and cytocompatibility of sulfonated PEEK. J Biomater Appl 2020; 35:342-352. [PMID: 32772686 DOI: 10.1177/0885328220935008] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Polyetheretherketone (PEEK) has been becoming a popular implant material in orthopaedic applications. The lack of bioactivity affects PEEK's long-term lifetime, and appropriate surface modification is an effective way to enhance its bioactivity. Sulfonation of PEEK can endow PEEK with a 3 D porous network surface and improve its bioactivity. This study is aimed at exploring an optimal sulfonation time and a post-treatment method of PEEK sulfonation. PEEK was immersed into concentrated sulfuric acid for different sulfonation times and experienced different post-treatment methods to turn into sulfonated PEEK (SPEEK). The immersion times were 0.5 min (SPEEK0.5), 1 min (SPEEK1), 3 min (SPEEK3), 5 min (SPEEK5) and 7 min (SPEEK7), and the post-treatment methods were acetone rinsing (SPEEK-T1), hydrothermal treatment (SPEEK-T2) and NaOH immersion (SPEEK-T3). Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy, hydrophilic property, ion release and cell viability evaluations were performed to optimize the sulfonation time, and the SEM, EDS, ion release and cell viability were analysed to optimize the post-treatment method. The results showed a porous network structure was formed on all samples of SPEEK, and the porous structure became more obvious and the S concentration increased with increasing sulfonation time. However, too long of an immersion time (SPEEK7) tended to damage the superficial porous structure and left a higher content of sulfuric acid, which could inhibit the growth of MC3T3E1 cells on its surface. In addition, the surface morphology, residual sulfuric acid and cytocompatibility of SPEEK-T1, SPEEK-T2 and SPEEK-T3 were not distinctly different. In conclusion, a 5-min sulfonation time was considered to be the optimal selection, and acetone rinsing, hydrothermal treatment and NaOH immersion showed the same effect in removing the residual sulfuric acid. The understanding of optimal sulfonation time and post-treatment method can provide a theoretical basis in preparing SPEEK for orthopaedic applications.
Collapse
Affiliation(s)
- Rui Ma
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Jialin Wang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Chengxin Li
- State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Kai Ma
- State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Jie Wei
- Key Laboratory for Ultrafine Materials of Ministry of Education, East China University of Science and Technology, Shanghai, China
| | - Pei Yang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Dagang Guo
- State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Kunzheng Wang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Wei Wang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
44
|
Raut HK, Das R, Liu Z, Liu X, Ramakrishna S. Biocompatibility of Biomaterials for Tissue Regeneration or Replacement. Biotechnol J 2020; 15:e2000160. [DOI: 10.1002/biot.202000160] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 06/19/2020] [Indexed: 12/25/2022]
Affiliation(s)
- Hemant Kumar Raut
- Division of Engineering Product Development Singapore University of Technology and Design 8 Somapah Rd Singapore 487372 Republic of Singapore
| | - Rupambika Das
- Division of Engineering Product Development Singapore University of Technology and Design 8 Somapah Rd Singapore 487372 Republic of Singapore
| | - Ziqian Liu
- Department of Mechanical Materials, and Manufacturing Engineering The University of Nottingham Ningbo, China 199 Taikang East Road Ningbo 315100 China
| | - Xiaoling Liu
- Department of Mechanical Materials, and Manufacturing Engineering The University of Nottingham Ningbo, China 199 Taikang East Road Ningbo 315100 China
| | - Seeram Ramakrishna
- Centre for Nanofibers and Nanotechnology Department of Mechanical Engineering National University of Singapore Singapore 117574 Singapore
| |
Collapse
|
45
|
Wu Y, Cao Y, Wu Y, Li D. Neutron Shielding Performance of 3D-Printed Boron Carbide PEEK Composites. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2314. [PMID: 32443451 PMCID: PMC7287577 DOI: 10.3390/ma13102314] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 05/04/2020] [Accepted: 05/15/2020] [Indexed: 11/21/2022]
Abstract
Polyethylene is used as a traditional shielding material in the nuclear industry, but still suffers from low softening point, poor mechanical properties, and difficult machining. In this study, novel boron carbide polyether-ether-ketone (PEEK) composites with different mass ratios were prepared and tested as fast neutron absorbers. Next, shielding test pieces with low porosity were rapidly manufactured through the fused deposition modeling (FDM)-3D printing optimization process. The respective heat resistances, mechanical properties, and neutron shielding characteristics of as-obtained PEEK and boron carbide PEEK composites with different thicknesses were then evaluated. At load of 0.45 MPa, the heat deformation temperature of boron carbide PEEK increased with the boron carbide content. The heat deformation temperature of 30% wt. boron carbide PEEK was recorded as 308.4 °C. After heat treatment, both tensile strength and flexural strength of PEEK and PEEK composites rose by 40%-50% and 65%-78%, respectively. Moreover, the as-prepared composites showed excellent fast neutron shielding performances. For shielding test pieces with thicknesses between 40 mm and 100 mm, the neutron shielding rates exhibited exponential variation as a function of boron carbide content. The addition of 5%-15% boron carbide significantly changed the curvature of the shielding rate curve, suggesting an optimal amount of boron carbide. Meanwhile, the integrated shielding/structure may effectively shield neutron radiation, thereby ensuring optimal shielding performances. In sum, further optimization of the proposed process could achieve lightweight materials with less consumables and small volume.
Collapse
Affiliation(s)
- Yin Wu
- School of Aerospace Engineering, Xi’an Jiaotong University, Xi’an 710049, China;
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China;
| | - Yi Cao
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China;
| | - Ying Wu
- Nuclear Power Institute of China, Chengdu 610213, China
| | - Dichen Li
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China;
| |
Collapse
|
46
|
Nakano H, Noguchi Y, Kakinoki S, Yamakawa M, Osaka I, Iwasaki Y. Highly Durable Lubricity of Photo-Cross-Linked Zwitterionic Polymer Brushes Supported by Poly(ether ether ketone) Substrate. ACS APPLIED BIO MATERIALS 2020; 3:1071-1078. [DOI: 10.1021/acsabm.9b01040] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Hiroki Nakano
- Graduate School of Science and Engineering, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
| | - Yuri Noguchi
- Graduate School of Science and Engineering, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
| | - Sachiro Kakinoki
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
- Organization for Research and Development of Innovative Science and Technology, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
| | - Mai Yamakawa
- Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectual University, 5180 Kurokawa, Imizu-City, Toyama 936-0398, Japan
| | - Issey Osaka
- Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectual University, 5180 Kurokawa, Imizu-City, Toyama 936-0398, Japan
| | - Yasuhiko Iwasaki
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
- Organization for Research and Development of Innovative Science and Technology, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-0836, Japan
| |
Collapse
|
47
|
Abstract
Human bones have unique structures and characteristics, and replacing a natural bone in the case of bone fracture or bone diseases is a very complicated problem. The main goal of this paper was to summarize the recent research on polymer materials as bone substitutes and for bone repair. Bone treatment methods, bone substitute materials as well as their advantages and drawbacks, and manufacturing methods were reviewed. Biopolymers are the most promising materials in the field of artificial bones and using biopolymers with the shape memory effect can improve the integration of an artificial bone into the human body by better mimicking the structure and properties of natural bones, decreasing the invasiveness of surgical procedures by producing deployable implants. It has been shown that the application of the rapid prototyping technology for artificial bones allows the customization of bone substitutes for a patient and the creation of artificial bones with a complex structure.
Collapse
Affiliation(s)
- Anastasiia Kashirina
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology, PO Box 301, No. 92 West Dazhi Street, Harbin 150001, China
| | - Yongtao Yao
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, No. 2 YiKuang Street, Harbin 150080, China.
| | - Yanju Liu
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology, PO Box 301, No. 92 West Dazhi Street, Harbin 150001, China
| | - Jinsong Leng
- National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, No. 2 YiKuang Street, Harbin 150080, China.
| |
Collapse
|