1
|
Kumar K, Fachet M, Hoeschen C. High-Spatial-Resolution Benchtop X-ray Fluorescence Imaging through Bragg-Diffraction-Based Focusing with Bent Mosaic Graphite Crystals: A Simulation Study. Int J Mol Sci 2024; 25:4733. [PMID: 38731956 PMCID: PMC11083219 DOI: 10.3390/ijms25094733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/18/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024] Open
Abstract
X-ray fluorescence imaging (XFI) can localize diagnostic or theranostic entities utilizing nanoparticle (NP)-based probes at high resolution in vivo, in vitro, and ex vivo. However, small-animal benchtop XFI systems demonstrating high spatial resolution (variable from sub-millimeter to millimeter range) in vivo are still limited to lighter elements (i.e., atomic number Z≤45). This study investigates the feasibility of focusing hard X-rays from solid-target tubes using ellipsoidal lens systems composed of mosaic graphite crystals with the aim of enabling high-resolution in vivo XFI applications with mid-Z (42≤Z≤64) elements. Monte Carlo simulations are performed to characterize the proposed focusing-optics concept and provide quantitative predictions of the XFI sensitivity, in silico tumor-bearing mice models loaded with palladium (Pd) and barium (Ba) NPs. Based on simulation results, the minimum detectable total mass of PdNPs per scan position is expected to be on the order of a few hundred nanograms under in vivo conform conditions. PdNP masses as low as 150 ng to 50 ng could be detectable with a resolution of 600 μm when imaging abdominal tumor lesions across a range of low-dose (0.8 μGy) to high-dose (8 μGy) exposure scenarios. The proposed focusing-optics concept presents a potential step toward realizing XFI with conventional X-ray tubes for high-resolution applications involving interesting NP formulations.
Collapse
Affiliation(s)
| | - Melanie Fachet
- Chair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University Magdeburg, 39106 Magdeburg, Germany; (K.K.)
| | | |
Collapse
|
2
|
Li L, Zhang S, Zhang W, Lu H. Full-field in vivoimaging of nanoparticles using benchtop cone-beam XFCT system with pixelated photon counting detector. Phys Med Biol 2023; 68. [PMID: 36646060 DOI: 10.1088/1361-6560/acb3aa] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 01/16/2023] [Indexed: 01/17/2023]
Abstract
Objective.X-ray fluorescence computed tomography (XFCT) is a promising noninvasive technique forin vivoimaging of high-Z elements (e.g. gadolinium (Gd) or gold (Au)). In this study we upgraded our experimental XFCT system using a flat panel photon counting detector with redesigned pinhole collimation in order to achieve 3D XFCT images during one scan.Approach.Aiming at the characteristics of pinhole-collimated cone-beam XFCT imaging, a new scatter correction algorithm was proposed to estimate the normalized spectrum of scatter background based on K-N formula and realize correction by a weighted least squares method. Then, images were quantitatively reconstructed by a maximum likelihood iterative algorithm with the attenuation correction.Main results.The potential on full-fieldin vivoXFCT imaging of this new system was investigated. An imaging experiment of a PMMA phantom with the diameter of 35 mm was carried out for quantitative evaluation of the system performance. Results show that 2 mg ml-1Gd solutions can be successfully reconstructed with a 45 min cone-beam XFCT scan.In vivoXFCT imaging experiments of mice with injection of Gd nanoparticles (GdNPs) were also performed and demonstrated in this paper. A mouse was injected through the tail vein with 20 mg ml-1NaGdF4 solution and then anesthetized with isoflurane during the cone-beam XFCT scan.Significance.The distribution of the GdNPs inside the mouse can be well reconstructed so that the deposition of NPsin vivocan be clearly observed, which indicates the feasibility of the proposed system for full-field XFCT of small animals and further potential in relevantin vivoresearch.
Collapse
Affiliation(s)
- Liang Li
- Department of Engineering Physics, Tsinghua University, Beijing, 100084, People's Republic of China.,Key Laboratory of Particle and Radiation imaging (Tsinghua University), Ministry of Education, Beijing, 100084, People's Republic of China
| | - Siyuan Zhang
- Department of Engineering Physics, Tsinghua University, Beijing, 100084, People's Republic of China.,Key Laboratory of Particle and Radiation imaging (Tsinghua University), Ministry of Education, Beijing, 100084, People's Republic of China
| | - Wenli Zhang
- School of Biomedical Engineering, Air Force Medical University, Xi'an, 710000, People's Republic of China.,Shanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, School of Biomedical Engineering, Air Force Medical University, Xi'an, 710000, People's Republic of China
| | - Hongbing Lu
- School of Biomedical Engineering, Air Force Medical University, Xi'an, 710000, People's Republic of China.,Shanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, School of Biomedical Engineering, Air Force Medical University, Xi'an, 710000, People's Republic of China
| |
Collapse
|