Jing B, Carrasco DI, AuYong N, Lindsey BD. A Transverse Velocity Spectral Estimation Method for Ultrafast Ultrasound Doppler Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1749-1760. [PMID: 37721880 PMCID: PMC10762297 DOI: 10.1109/tuffc.2023.3316748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/20/2023]
Abstract
A novel transverse velocity spectral estimation method is proposed to estimate the velocity component in the direction transverse to the beam axis for ultrafast imaging. The transverse oscillation was introduced by filtering the envelope data after the axial oscillation was removed. The complex transverse oscillated signal was then used to estimate the transverse velocity spectrum and mean velocity. In simulations, both steady flow with a parabolic flow profile and temporally varying flow were simulated to investigate the performance of the proposed method. Next, the proposed approach was used to estimate the flow velocity in a phantom with pulsatile flow, and finally, this method was applied in vivo in a small animal model. Results of the simulation study indicate that the proposed method provided an accurate velocity spectrogram for beam-to-flow angles from 45° to 90°, without significant performance degradation as the angle decreased. For the simulation of temporally varying flow, the proposed method had a reduced bias ( % versus 73.3%) and higher peak-to-background ratio (PBR) (>15.6 versus 10.5 dB) compared to previous methods. Results in a vessel phantom show that the temporally varying flow velocity can be estimated in the transverse direction obtained using the spectrogram produced by the proposed method operating on the envelope data. Finally, the proposed method was used to map the microvascular blood flow velocity in the mouse spinal cord, demonstrating the estimation of pulsatile blood flow in both the axial and transverse directions in vivo over several cardiac cycles.
Collapse
|
2
|
Liang S, Lu M. Advanced Fourier migration for Plane-Wave vector flow imaging. ULTRASONICS 2023; 132:107001. [PMID: 37094522 DOI: 10.1016/j.ultras.2023.107001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 03/20/2023] [Accepted: 03/31/2023] [Indexed: 05/03/2023]
Abstract
Ultrafast ultrasound imaging modalities have been studied extensively in the ultrasound community. It breaks the compromise between the frame rate and the region of interest by imaging the whole medium with wide unfocused waves. Continuously available data allow monitoring fast transient dynamics at hundreds to thousands of frames per second. This feature enables a more accurate and robust velocity estimation in vector flow imaging (VFI). On the other hand, the huge amount of data and real-time processing demands are still challenging in VFI. A solution is to provide a more efficient beamforming approach with smaller computation complexity than the conventional time-domain beamformer like delay-and-sum (DAS). Fourier-domain beamformers are shown to be more computationally efficient and can provide equally good image quality as DAS. However, previous studies generally focus on B-mode imaging. In this study, we propose a new framework for VFI which is based on two advanced Fourier migration methods, namely, slant stack migration (SSM) and ultrasound Fourier slice beamform (UFSB). By carefully modifying the beamforming parameters, we successfully apply the cross-beam technique within the Fourier beamformers. The proposed Fourier-based VFI is validated in simulation studies, in vitro, and in vivo experiments. The velocity estimation is evaluated via bias and standard deviation and the results are compared with conventional time-domain VFI using the DAS beamformer. In the simulation, the bias is 6.4%, -6.2%, and 5.7%, and the standard deviation is 4.3%, 2.4%, and 3.9% for DAS, UFSB, and SSM, respectively. In vitro studies reveal a bias of 4.5%, -5.3%, and 4.3% and a standard deviation of 3.5%, 1.3%, and 1.6% from DAS, UFSB, and SSM, respectively. The in vivo imaging of the basilic vein and femoral bifurcation also generate similar results using all three methods. With the proposed Fourier beamformers, the computation time can be shortened by up to 9 times and 14 times using UFSB and SSM.
Collapse
Affiliation(s)
- Siyi Liang
- United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China.
| | - Minhua Lu
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, China.
| |
Collapse
|
3
|
Haniel J, Yiu BYS, Chee AJY, Huebner R, Yu ACH. Efficacy of ultrasound vector flow imaging in tracking omnidirectional pulsatile flow. Med Phys 2023; 50:1699-1714. [PMID: 36546560 DOI: 10.1002/mp.16168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Ultrasound vector flow imaging (VFI) shows potential as an emerging non-invasive modality for time-resolved flow mapping. However, its efficacy in tracking multidirectional pulsatile flow with temporal resolvability has not yet been systematically evaluated because of the lack of an appropriate test protocol. PURPOSE We present the first systematic performance investigation of VFI in tracking pulsatile flow in a meticulously designed scenario with time-varying, omnidirectional flow fields (with flow angles from 0° to 360°). METHODS Ultrasound VFI was performed on a three-loop spiral flow phantom (4 mm diameter; 5 mm pitch) that was configured to operate under pulsatile flow conditions (10 ml/s peak flow rate; 1 Hz pulse rate; carotid pulse shape). The spiral lumen geometry was designed to simulate recirculatory flow dynamics observed in the heart and in curvy blood vessel segments such as the carotid bulb. The imaging sequence was based on steered plane wave pulsing (-10°, 0°, +10° steering angles; 5 MHz imaging frequency; 3.3 kHz interleaved pulse repetition frequency). VFI's pulsatile flow estimation performance and its ability to detect secondary flow were comparatively assessed against flow fields derived from computational fluid dynamics (CFD) simulations that included consideration of fluid-structure interactions (FSI). The mean percentage error (MPE) and the coefficient of determination (R2 ) were computed to assess the correspondence of the velocity estimates derived from VFI and CFD-FSI simulations. In addition, VFI's efficacy in tracking pulse waves was analyzed with respect to pressure transducer measurements made at the phantom's inlet and outlet. RESULTS Pulsatile flow patterns rendered by VFI agreed with the flow profiles computed from CFD-FSI simulations (average MPE: -5.3%). The shape of the VFI-measured velocity magnitude profile generally matched the inlet flow profile. High correlation exists between VFI measurements and simulated flow vectors (lateral velocity: R2 = 0.8; axial velocity R2 = 0.89; beam-flow angle: R2 = 0.98; p < 0.0001 for all three quantities). VFI was found to be capable of consistently tracking secondary flow. It also yielded pulse wave velocity (PWV) estimates (5.72 ± 1.02 m/s) that, on average, are within 6.4% of those obtained from pressure transducer measurements (6.11 ± 1.15 m/s). CONCLUSION VFI can consistently track omnidirectional pulsatile flow on a time-resolved basis. This systematic investigation serves well as a quality assurance test of VFI.
Collapse
Affiliation(s)
- Jonathas Haniel
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
- Department of Mechanical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Billy Y S Yiu
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Adrian J Y Chee
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Rudolf Huebner
- Department of Mechanical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Alfred C H Yu
- Schlegel Research Institute for Aging and Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
4
|
Dong Y, Hong S, Song D, Liu M, Gao W, Du Y, Xu J, Dong F. Blood Flow Turbulence Quantification of Carotid Artery With a High-Frame Rate Vector Flow Imaging. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:427-436. [PMID: 35716339 DOI: 10.1002/jum.16039] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/17/2022] [Accepted: 05/27/2022] [Indexed: 06/15/2023]
Abstract
OBJECTIVES To assess the feasibility and performance of Turbulence (Tur) index as a quantitative tool for carotid artery flow turbulence; to detect and compare the blood flow patterns of common carotid artery (CCA) and carotid bulb (CB) at different ages and cardiac phases in healthy adults, and thus interpret the evolvement of etiology difference between CCA and CB. METHODS Carotid flow characteristics of 40 healthy volunteers were evaluated quantitatively by a high-frame rate vector flow imaging. Three types of flow patterns were defined depending on the distributive range of complex flow during systole in CB. Comparison of mean Tur value in CCA and CB at different age groups and cardiac phases was performed. And the correlation between Tur value and the diameter ratio of proximal internal carotid artery to common carotid artery (DRpro-ica/cca) was tested. RESULTS Mean Tur values in CB were remarkably higher than that in CCA, whether during systole or diastole (P < .001). Meanwhile Tur values in CB during systole were significantly higher than that during diastole (P < .001). Flow complexity of CB showed variations among 40 participants especially in systole, whereas the flow pattern of CCA was relatively consistent. Mean Tur values were positively correlated with DRpro-ica/cca in CB (ρ = 0.69, P < .05). CONCLUSIONS V Flow imaging provided a reliable method-Tur, for quantitative analysis of carotid blood flow. It had potential to be further applied in distinguishing complex hemodynamic characteristics in high-risk people of carotid diseases for the risk stratification of cardiovascular events.
Collapse
Affiliation(s)
- Yinghui Dong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Shaofu Hong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Di Song
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Mengmeng Liu
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Wenjing Gao
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Yigang Du
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Jinfeng Xu
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Fajin Dong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| |
Collapse
|
5
|
Hasegawa H, Omura M, Nagaoka R, Saito K. Two-Dimensional Wavenumber Analysis Implemented in Ultrasonic Vector Doppler Method with Focused Transmit Beams. SENSORS (BASEL, SWITZERLAND) 2022; 22:9787. [PMID: 36560161 PMCID: PMC9781179 DOI: 10.3390/s22249787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/05/2022] [Accepted: 12/09/2022] [Indexed: 06/17/2023]
Abstract
The multi-angle Doppler method was introduced for the estimation of velocity vectors by measuring axial velocities from multiple directions. We have recently reported that the autocorrelation-based velocity vector estimation could be ameliorated significantly by estimating the wavenumbers in two dimensions. Since two-dimensional wavenumber estimation requires a snapshot of an ultrasonic field, the method was first implemented in plane wave imaging. Although plane wave imaging is predominantly useful for examining blood flows at an extremely high temporal resolution, it was reported that the contrast in a B-mode image obtained with a few plane wave emissions was lower than that obtained with focused beams. In this study, the two-dimensional wavenumber analysis was first implemented in a framework with focused transmit beams. The simulations showed that the proposed method achieved an accuracy in velocity estimation comparable to that of the method with plane wave imaging. Furthermore, the performances of the methods implemented in focused beam and plane wave imaging were compared by measuring human common carotid arteries in vivo. Image contrasts were analyzed in normal and clutter-filtered B-mode images. The method with focused beam imaging achieved a better contrast in normal B-mode imaging, and similar velocity magnitudes and angles were obtained by both the methods with focused beam and plane wave imaging. In contrast, the method with plane wave imaging gave a better contrast in a clutter-filtered B-mode image and smaller variances in velocity magnitudes than those with focused beams.
Collapse
Affiliation(s)
- Hideyuki Hasegawa
- Faculty of Engineering, University of Toyama, Toyama 930-8555, Japan
| | - Masaaki Omura
- Faculty of Engineering, University of Toyama, Toyama 930-8555, Japan
| | - Ryo Nagaoka
- Faculty of Engineering, University of Toyama, Toyama 930-8555, Japan
| | - Kozue Saito
- Department of Neurology, Stroke Center, Nara Medical University, Nara 634-8522, Japan
| |
Collapse
|
6
|
Shen CC, Guo FT. Ultrasound Ultrafast Power Doppler Imaging with High Signal-to-Noise Ratio by Temporal Multiply-and-Sum (TMAS) Autocorrelation. SENSORS (BASEL, SWITZERLAND) 2022; 22:8349. [PMID: 36366046 PMCID: PMC9655537 DOI: 10.3390/s22218349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/21/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
Coherent plane wave compounding (CPWC) reconstructs transmit focusing by coherently summing several low-resolution plane-wave (PW) images from different transmit angles to improve its image resolution and quality. The high frame rate of CPWC imaging enables a much larger number of Doppler ensembles such that the Doppler estimation of blood flow becomes more reliable. Due to the unfocused PW transmission, however, one major limitation of the Doppler estimation in CPWC imaging is the relatively low signal-to-noise ratio (SNR). Conventionally, the Doppler power is estimated by a zero-lag autocorrelation which reduces the noise variance, but not the noise level. A higher-lag autocorrelation method such as the first-lag (R(1)) power Doppler image has been developed to take advantage of the signal coherence in the temporal direction for suppressing uncorrelated random noises. In this paper, we propose a novel Temporal Multiply-and-Sum (TMAS) power Doppler detection method to further improve the noise suppression of the higher-lag method by modulating the signal coherence among the temporal correlation pairs in the higher-lag autocorrelation with a tunable pt value. Unlike the adaptive beamforming methods which demand for either receive-channel-domain or transmit-domain processing to exploit the spatial coherence of the blood flow signal, the proposed TMAS power Doppler can share the routine beamforming architecture with CPWC imaging. The simulated results show that when it is compared to the original R(1) counterpart, the TMAS power Doppler image with the pt value of 2.5 significantly improves the SNR by 8 dB for the cross-view flow velocity within the Nyquist rate. The TMAS power Doppler, however, suffers from the signal decorrelation of the blood flow, and thus, it relies on not only the pt value and the flow velocity, but also the flow direction relative to the geometry of acoustic beam. The experimental results in the flow phantom and in vivo dataset also agree with the simulations.
Collapse
Affiliation(s)
- Che-Chou Shen
- Correspondence: ; Tel.: +886-2-27301229; Fax: +886-2-27376699
| | | |
Collapse
|
7
|
Madhavanunni A, Panicker MR. A nonlinear beamforming for enhanced spatiotemporal sensitivity in high frame rate ultrasound flow imaging. Comput Biol Med 2022; 147:105686. [DOI: 10.1016/j.compbiomed.2022.105686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/26/2022] [Accepted: 05/30/2022] [Indexed: 11/03/2022]
|
8
|
Hasegawa H, Omura M, Nagaoka R. On the Investigation of Autocorrelation-Based Vector Doppler Method With Plane Wave Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1301-1311. [PMID: 35171769 DOI: 10.1109/tuffc.2022.3152186] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Although color flow imaging is one of the representative applications of the Doppler method, it can estimate only the velocity component in the direction of ultrasonic propagation, that is, the axial velocity component. The vector Doppler method with high-frame-rate plane wave imaging overcomes such a limitation by estimating the blood flow velocity vectors using the axial velocities obtained by emitting plane waves in multiple directions. The autocorrelation technique can be used for the estimation of the axial velocity using the phase shift of an ultrasonic echo signal between two transmit-receive events. The technique also requires the frequency of the received echo signal. Although the center frequency of the emitted ultrasonic signal is commonly used in the estimation of axial velocities, the center frequency should be estimated from the received signals. In this study, a method for the estimation of the center frequency designed particularly for the high-frame-rate plane wave imaging was developed. The proposed method estimates the wavenumbers of the received signal in lateral and vertical directions to estimate the wavenumber in the axial direction, from which the center frequency was estimated. The beam steering angle was also estimated from the wavenumbers in the two directions. The effect of the proposed method was validated in simulations. The absolute bias error (ABE) and root-mean squared error in estimated velocity vectors obtained by plane wave imaging with three beam steering angles (-15°, 0°, and 15°) were reduced from 9.27% and 14.80% to 1.15% and 8.75%, respectively, by the proposed method. The applicability of the proposed method to in vivo measurements was also demonstrated using the in vivo recordings of human common carotid arteries. Physiologically consistent blood flow velocity distributions were obtained with respect to three subjects using the proposed method.
Collapse
|
9
|
Kim S, Jing B, Lindsey BD. Forward-viewing estimation of 3D blood flow velocity fields by intravascular ultrasound: Influence of the catheter on velocity estimation in stenoses. ULTRASONICS 2021; 117:106558. [PMID: 34461527 PMCID: PMC8448960 DOI: 10.1016/j.ultras.2021.106558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/02/2021] [Accepted: 08/17/2021] [Indexed: 06/13/2023]
Abstract
Coronary artery disease is the most common type of cardiovascular disease, affecting > 18 million adults, and is responsible for > 365 k deaths per year in the U.S. alone. Wall shear stress (WSS) is an emerging indicator of likelihood of plaque rupture in coronary artery disease, however, non-invasive estimation of 3-D blood flow velocity and WSS is challenging due to the requirement for high spatial resolution at deep penetration depths in the presence of significant cardiac motion. Thus we propose minimally-invasive imaging with a catheter-based, 3-D intravascular forward-viewing ultrasound (FV US) transducer and present experiments to quantify the effect of the catheter on flow disturbance in stenotic vessel phantoms with realistic velocities and luminal diameters for both peripheral (6.33 mm) and coronary (4.74 mm) arteries. An external linear array ultrasound transducer was used to quantify 2-D velocity fields in vessel phantoms under various conditions of catheter geometry, luminal diameter, and position of the catheter relative to the stenosis at a frame rate of 5000 frames per second via a particle imaging velocimetry (PIV) approach. While a solid catheter introduced an underestimation of velocity measurement by > 20% relative to the case without a catheter, the hollow catheter introduced < 10% velocity overestimation, indicating that a hollow catheter design allowing internal blood flow reduces hemodynamic disturbance. In addition, for both peripheral and coronary arteries, the hollow catheter introduced < 3% deviation in flow velocity at the minimum luminal area compared to the control case. Finally, an initial comparison was made between velocity measurements acquired using a low frequency, catheter-based, 3-D intravascular FV US transducer and external linear array measurements, with relative error < 12% throughout the region of interest for a flow rate of 150 mL/min. While further system development is required, results suggest intravascular ultrasound characterization of blood flow velocity fields in stenotic vessels could be feasible with appropriate catheter design.
Collapse
Affiliation(s)
- Saeyoung Kim
- Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, 801 Ferst Dr., Atlanta, GA 30332, USA; Georgia Institute of Technology, Interdisciplinary BioEngineering Graduate Program, 315 Ferst Dr., Atlanta, GA 30332, USA
| | - Bowen Jing
- Georgia Institute of Technology and Emory University, Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Dr NW, Atlanta, GA 30332, USA
| | - Brooks D Lindsey
- Georgia Institute of Technology, Interdisciplinary BioEngineering Graduate Program, 315 Ferst Dr., Atlanta, GA 30332, USA; Georgia Institute of Technology and Emory University, Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Dr NW, Atlanta, GA 30332, USA.
| |
Collapse
|
10
|
Madhavanunni AN, Raveendranatha Panicker M. An Angle Independent Depth Aware Fusion Beamforming Approach for Ultrafast Ultrasound Flow Imaging . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:3399-3402. [PMID: 34891969 DOI: 10.1109/embc46164.2021.9630742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In the case of vector flow imaging systems, the most employed flow estimation techniques are the directional beamforming based cross correlation and the triangulation-based autocorrelation. However, the directional beamforming-based techniques require an additional angle estimator and are not reliable if the flow angle is not constant throughout the region of interest. On the other hand, estimates with triangulation-based techniques are prone to large bias and variance at low imaging depths due to limited angle for left and right apertures. In view of this, a novel angle independent depth aware fusion beamforming approach is proposed and evaluated in this paper. The hypothesis behind the proposed approach is that the peripheral flows are transverse in nature, where directional beamforming can be employed without the need of an angle estimator and the deeper flows being non-transverse and directional, triangulation-based vector flow imaging can be employed. In the simulation study, an overall 67.62% and 74.71% reduction in magnitude bias along with a slight reduction in the standard deviation are observed with the proposed fusion beamforming approach when compared to triangulation-based beamforming and directional beamforming, respectively, when implemented individually. The efficacy of the proposed approach is demonstrated with in-vivo experiments.
Collapse
|
11
|
Ilaria P, Mario M, Ilaria F. Advances in vascular anatomy and pathophysiology using high resolution and multiparametric sonography. J Vasc Access 2021; 22:1-8. [PMID: 34338066 PMCID: PMC8606621 DOI: 10.1177/11297298211020150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
B-mode and Color Doppler are the first-line imaging modalities in cardiovascular diseases. However, conventional ultrasound (US) provides a lower spatial and temporal resolution (70-100 frames per second) compared to ultrafast technology which acquires several thousand frames per second. Consequently, the multiparametric ultrafast platforms manage new imaging algorithms as high-frequency ultrasound, contrast-enhanced ultrasound, shear wave elastography, vector flow, and local pulse wave imaging. These advances allow better ultrasound performances, more detailed blood flow visualization and vessel walls' characterization, and many future applications for vascular viscoelastic properties evaluation.In this paper, we provide an overview of each new technique's principles and concepts and the real or potential applications of these modalities on the study of the artery and venous anatomy and pathophysiology of the upper limb before and after creating a native or prosthetic arterio-venous fistula. In particular, we focus on high-frequency ultrasound that could predict cannulation readiness and its potential role in the venous valvular status evaluation before vascular access creation; on contrast-enhanced ultrasound that could improve the peri-operative imaging evaluation during US-guided angioplasty; on shear wave elastography and local pulse wave imaging that could evaluate preoperative vessels stiffness and their potential predictive role in vascular access failure; on vector flow imaging that could better characterize the different components of the vascular access complex flow.
Collapse
Affiliation(s)
- Petrucci Ilaria
- Institute of Life Sciences, S. Anna School of Advanced Studies, Pisa, Italy
| | - Meola Mario
- Institute of Life Sciences, S. Anna School of Advanced Studies, Department of Internal Medicine, University of Pisa, Pisa, Italy
| | - Fiorina Ilaria
- Radiodiagnostic and Interventional Radiology Department, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| |
Collapse
|
12
|
Rossi S, Ramalli A, Tortoli P. On the Depth-Dependent Accuracy of Plane-Wave-Based Vector Velocity Measurements With Linear Arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2707-2715. [PMID: 33909562 DOI: 10.1109/tuffc.2021.3076284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
High-frame-rate vector Doppler methods are used to measure blood velocities over large 2-D regions, but their accuracy is often estimated over a short range of depths. This article thoroughly examines the dependence of velocity measurement accuracy on the target position. Simulations were carried out on flat and parabolic flow profiles, for different Doppler angles, and considering a 2-D vector flow imaging (2-D VFI) method based on plane wave transmission and speckle tracking. The results were also compared with those obtained by the reference spectral Doppler (SD) method. Although, as expected, the bias and standard deviation generally tend to worsen at increasing depths, the measurements also show the following. First, the errors are much lower for the flat profile (from ≈ -4 ± 3% at 20 mm to ≈ -17 ± 4% at 100 mm) than for the parabolic profile (from ≈ -4 ± 3% to ≈ -38 ±%). Second, only part of the relative estimation error is related to the inherent low resolution of the 2-D VFI method. For example, even for SD, the error bias increases (on average) from -0.7% (20 mm) to -17% (60 mm) up to -26% (100 mm). Third, conversely, the beam divergence associated with the linear array acoustic lens was found to have a great impact on the velocity measurements. By simply removing such lens, the average bias for 2-D VFI at 60 and 100 mm dropped down to -9.4% and -19.4%, respectively. In conclusion, the results indicate that the transmission beam broadening on the elevation plane, which is not limited by reception dynamic focusing, is the main cause of velocity underestimation in the presence of high spatial gradients.
Collapse
|
13
|
Measurement of flow velocity vectors in carotid artery using plane wave imaging with repeated transmit sequence. J Med Ultrason (2001) 2021; 48:417-427. [PMID: 34287752 DOI: 10.1007/s10396-021-01113-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 06/17/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Doppler-based methods are widely used for blood flow imaging in clinical settings. However, they inherently estimate the velocity component only in the axial direction. Therefore, various studies of angle-independent methods have been conducted. The multi-angle Doppler method is one such angle-independent method, in which the velocity vector is estimated using axial velocities obtained from multiple directions by steering an ultrasonic beam. Recently, plane wave imaging, which realizes a very high frame rate of several thousand frames per second, was applied to the multi-angle Doppler method. However, the maximum detectable velocity, i.e., the aliasing limit, was reduced depending on the number of steering angles. In the present study, the feasibility of a specific transmit sequence, namely, the repeated transmit sequence, was examined using the plane-wave multi-angle Doppler method. METHOD In the repeated transmit sequence, plane waves were emitted to the same direction twice, after which the steering angle was changed. By repeating the same procedure, a pair of beamformed radio-frequency (RF) signals could be obtained under each beam steering angle. By applying the autocorrelation method to each pair of RF signals, the time interval between the RF signals could be kept as the pulse repetition interval (PRI). The feasibility of such a transmit sequence was examined by numerical simulation and in vivo measurement of a human carotid artery. RESULTS The simulation results showed that the maximum steering angles of over 10 degrees were not feasible with the linear array used in the present study. The feasible maximum steering angle would depend on the element pitch of the probe relative to the ultrasonic wavelength. By limiting the maximum steering angles to 5 and 10 degrees, bias errors were 9.2% and 11.3%, respectively, and root mean squared errors were 21.5% and 16.9%, respectively. Also, flow velocity vectors in a human carotid artery could be visualized with the proposed method. CONCLUSION The multi-angle Doppler method was implemented in plane wave imaging with the repeated transmit sequence, and the proposed method was shown to be feasible through numerical simulation and in vivo measurement of a carotid artery.
Collapse
|
14
|
Shen CC, Chu YC. DMAS Beamforming with Complementary Subset Transmit for Ultrasound Coherence-Based Power Doppler Detection in Multi-Angle Plane-Wave Imaging. SENSORS 2021; 21:s21144856. [PMID: 34300594 PMCID: PMC8309888 DOI: 10.3390/s21144856] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 06/30/2021] [Accepted: 07/13/2021] [Indexed: 11/24/2022]
Abstract
Conventional ultrasonic coherent plane-wave (PW) compounding corresponds to Delay-and-Sum (DAS) beamforming of low-resolution images from distinct PW transmit angles. Nonetheless, the trade-off between the level of clutter artifacts and the number of PW transmit angle may compromise the image quality in ultrafast acquisition. Delay-Multiply-and-Sum (DMAS) beamforming in the dimension of PW transmit angle is capable of suppressing clutter interference and is readily compatible with the conventional method. In DMAS, a tunable p value is used to modulate the signal coherence estimated from the low-resolution images to produce the final high-resolution output and does not require huge memory allocation to record all the received channel data in multi-angle PW imaging. In this study, DMAS beamforming is used to construct a novel coherence-based power Doppler detection together with the complementary subset transmit (CST) technique to further reduce the noise level. For p = 2.0 as an example, simulation results indicate that the DMAS beamforming alone can improve the Doppler SNR by 8.2 dB compared to DAS counterpart. Another 6-dB increase in Doppler SNR can be further obtained when the CST technique is combined with DMAS beamforming with sufficient ensemble averaging. The CST technique can also be performed with DAS beamforming, though the improvement in Doppler SNR and CNR is relatively minor. Experimental results also agree with the simulations. Nonetheless, since the DMAS beamforming involves multiplicative operation, clutter filtering in the ensemble direction has to be performed on the low-resolution images before DMAS to remove the stationary tissue without coupling from the flow signal.
Collapse
Affiliation(s)
- Che-Chou Shen
- Correspondence: ; Tel.: +886-2-27301229; Fax: +886-2-27376699
| | | |
Collapse
|
15
|
Giangrossi C, Meacci V, Ricci S, Matera R, Boni E, Dallai A, Tortoli P. Virtual Real-Time for High PRF Multiline Vector Doppler on ULA-OP 256. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:624-631. [PMID: 32813652 DOI: 10.1109/tuffc.2020.3017940] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The recent development of high-frame-rate (HFR) imaging/Doppler methods based on the transmission of plane or diverging waves has proposed new challenges to echographic data management and display. Due to the huge amount of data that need to be processed at very high speed, the pulse repetition frequency (PRF) is typically limited to hundreds hertz or few kilohertz. In Doppler applications, a PRF limitation may result unacceptable since it inherently translates to a corresponding limitation in the maximum detectable velocity. In this article, the ULA-OP 256 implementation of a novel ultrasound modality, called virtual real-time (VRT), is described. First, for a given HFR RT modality, the scanner displays the processed results while saving channel data into an internal buffer. Then, ULA-OP 256 switches to VRT mode, according to which the raw data stored in the buffer are immediately reprocessed by the same hardware used in RT. In the two phases, the ULA-OP 256 calculation power can be differently distributed to increase the acquisition frame rate or the quality of processing results. VRT was here used to extend the PRF limit in a multiline vector Doppler (MLVD) application. In RT, the PRF was maximized at the expense of the display quality; in VRT, data were reprocessed at a lower rate in a high-quality display format, which provides more detailed flow information. Experiments are reported in which the MLVD technique is shown capable of working at 16-kHz PRF, so that flow jet velocities higher up to 3 m/s can be detected.
Collapse
|
16
|
Perrot V, Ekroll IK, Avdal J, Saxhaug LM, Dalen H, Vray D, Lovstakken L, Liebgott H. Translation of Simultaneous Vessel Wall Motion and Vectorial Blood Flow Imaging in Healthy and Diseased Carotids to the Clinic: A Pilot Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:558-569. [PMID: 32776877 DOI: 10.1109/tuffc.2020.3015340] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This study aims to investigate the clinical feasibility of simultaneous extraction of vessel wall motion and vectorial blood flow at high frame rates for both extraction of clinical markers and visual inspection. If available in the clinic, such a technique would allow a better estimation of plaque vulnerability and improved evaluation of the overall arterial health of patients. In this study, both healthy volunteers and patients were recruited and scanned using a planewave acquisition scheme that provided a data set of 43 carotid recordings in total. The vessel wall motion was extracted based on the complex autocorrelation of the signals received, while the vector flow was extracted using the transverse oscillation technique. Wall motion and vector flow were extracted at high frame rates, which allowed for a visual appreciation of tissue movement and blood flow simultaneously. Several clinical markers were extracted, and visual inspections of the wall motion and flow were conducted. From all the potential markers, young healthy volunteers had smaller artery diameter (7.72 mm) compared with diseased patients (9.56 mm) ( p -value ≤ 0.001), 66% of diseased patients had backflow compared with less than 10% for the other patients ( p -value ≤ 0.05), a carotid with a pulse wave velocity extracted from the wall velocity greater than 7 m/s was always a diseased vessel, and the peak wall shear rate decreased as the risk increases. Based on both the pathological markers and the visual inspection of tissue motion and vector flow, we conclude that the clinical feasibility of this approach is demonstrated. Larger and more disease-specific studies using such an approach will lead to better understanding and evaluation of vessels, which can translate to future use in the clinic.
Collapse
|
17
|
Hoving AM, Voorneveld J, Mikhal J, Bosch JG, Groot Jebbink E, Slump CH. In vitro performance of echoPIV for assessment of laminar flow profiles in a carotid artery stent. J Med Imaging (Bellingham) 2021; 8:017001. [PMID: 33457445 PMCID: PMC7804295 DOI: 10.1117/1.jmi.8.1.017001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 12/22/2020] [Indexed: 11/14/2022] Open
Abstract
Purpose: Detailed blood flow studies may contribute to improvements in carotid artery stenting. High-frame-rate contrast-enhanced ultrasound followed by particle image velocimetry (PIV), also called echoPIV, is a technique to study blood flow patterns in detail. The performance of echoPIV in presence of a stent has not yet been studied extensively. We compared the performance of echoPIV in stented and nonstented regions in an in vitro flow setup. Approach: A carotid artery stent was deployed in a vessel-mimicking phantom. High-frame-rate contrast-enhanced ultrasound images were acquired with various settings. Signal intensities of the contrast agent, velocity values, and flow profiles were calculated. Results: The results showed decreased signal intensities and correlation coefficients inside the stent, however, PIV analysis in the stent still resulted in plausible flow vectors. Conclusions: Velocity values and laminar flow profiles can be measured in vitro in stented arteries using echoPIV.
Collapse
Affiliation(s)
- Astrid M Hoving
- University of Twente, TechMed Centre, Robotics and Mechatronics Group, Enschede, The Netherlands
| | - Jason Voorneveld
- Erasmus MC, Thorax Center, Department of Biomedical Engineering, Rotterdam, The Netherlands
| | - Julia Mikhal
- University of Twente, TechMed Centre, BIOS Lab-on-a-Chip Group, Enschede, The Netherlands
| | - Johan G Bosch
- Erasmus MC, Thorax Center, Department of Biomedical Engineering, Rotterdam, The Netherlands
| | - Erik Groot Jebbink
- University of Twente, TechMed Centre, Multi-Modality Medical Imaging Group, Enschede, The Netherlands
| | - Cornelis H Slump
- University of Twente, TechMed Centre, Robotics and Mechatronics Group, Enschede, The Netherlands
| |
Collapse
|
18
|
Investigation of feasibility of singular value decomposition clutter filter in plane wave imaging with packet transmission sequence. J Med Ultrason (2001) 2021; 48:13-20. [DOI: 10.1007/s10396-020-01067-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 10/16/2020] [Indexed: 10/22/2022]
|
19
|
Kripfgans OD, Rubin JM, Pinter SZ, Jago J, Leichner R, Brian Fowlkes J. Partial Volume Effect and Correction for 3-D Color Flow Acquisition of Volumetric Blood Flow. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1749-1759. [PMID: 31403411 PMCID: PMC6874830 DOI: 10.1109/tuffc.2019.2934119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Blood volume flow (VF) estimation is becoming an integral part of quantitative medical imaging. Three-dimensional color flow can be used to measure volumetric flow, but partial volume correction (PVC) is essential due to finite beamwidths and lumen diameters. Color flow power was previously assumed to be directly proportional to the perfused fractional color flow beam area (voxel). We investigate the relationship between color flow power and fractionally perfused voxels. We simulate 3-D color flow imaging using Field II based on a 3.75-MHz mechanically swept linear array. A 16-mm-diameter tube with laminar flow was embedded into soft tissue. We investigated two study scenarios where soft tissue backscatter is 1) 40 dB higher and 2) 40 dB lower, relative to blood. Velocity and power were computed from color flow packets ( n = 16 ) using autocorrelation. Study 1 employed a convolution-based wall filter. Study 2 did not employ a wall filter. VF was computed from the resulting color flow data, as published previously. Partial volume voxels in Study 1 show lesser power than those in Study 2, likely due to wall filter effects. An "S"-shaped relationship was found between color flow power and fractionally perfused voxel area in Study 2, which could be due to an asymmetric lateral-elevational point spread function. Flow computation is biased low by 7.3% and 7.9% in Study 1 and Study 2, respectively. Uncorrected simulation estimates are biased high by 41.5% and 12.5% in Study 1 and Study 2, respectively. Our findings show that PVC improves 3-D VF estimation and that wall filter processing alters the proportionality between color flow power and fractionally perfused voxel area.
Collapse
|
20
|
Saris AECM, Hansen HHG, Fekkes S, Menssen J, Nillesen MM, de Korte CL. In Vivo Blood Velocity Vector Imaging Using Adaptive Velocity Compounding in the Carotid Artery Bifurcation. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1691-1707. [PMID: 31079874 DOI: 10.1016/j.ultrasmedbio.2019.03.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 03/06/2019] [Accepted: 03/10/2019] [Indexed: 06/09/2023]
Abstract
Visualization and quantification of blood flow are considered important for early detection of atherosclerosis and patient-specific diagnosis and intervention. As conventional Doppler imaging is limited to 1-D velocity estimates, 2-D and 3-D techniques are being developed. We introduce an adaptive velocity compounding technique that estimates the 2-D velocity vector field using predominantly axial displacements estimated by speckle tracking from dual-angle plane wave acquisitions. Straight-vessel experiments with a 7.8-MHz linear array transducer connected to a Verasonics Vantage ultrasound system revealed that the technique performed with a maximum velocity magnitude bias and angle bias of -3.7% (2.8% standard deviation) and -0.16° (0.41° standard deviation), respectively. In vivo, complex flow patterns were visualized in two healthy and three diseased carotid arteries and quantified using a vector complexity measure that increased with increasing wall irregularity. This measure could potentially be a relevant clinical parameter which might aid in early detection of atherosclerosis.
Collapse
Affiliation(s)
- Anne E C M Saris
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Stein Fekkes
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Jan Menssen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Maartje M Nillesen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Chris L de Korte
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands; Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| |
Collapse
|
21
|
Di Ianni T, Hansen KL, Villagomez Hoyos CA, Moshavegh R, Nielsen MB, Jensen JA. Portable Vector Flow Imaging Compared With Spectral Doppler Ultrasonography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:453-462. [PMID: 30281442 DOI: 10.1109/tuffc.2018.2872508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study, a vector flow imaging (VFI) method developed for a portable ultrasound scanner was used for estimating peak velocity values and variation in beam-to-flow angle over the cardiac cycle in vivo on healthy volunteers. Peak-systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) measured with VFI were compared to spectral Doppler ultrasonography (SDU). Seventeen healthy volunteers were scanned on the left and right common carotid arteries (CCAs). The standard deviation (SD) of VFI measurements averaged over the cardiac cycle was 7.3% for the magnitude and 3.84° for the angle. Bland-Altman plots showed a positive bias for the PSV measured with SDU (mean difference: 0.31 ms -1 ), and Pearson correlation analysis showed a highly significant correlation ( r = 0.6 ; ). A slightly positive bias was found for EDV and RI measured with SDU (mean difference: 0.08 ms -1 and -0.01 ms -1 , respectively). However, the correlation was low and not significant. The beam-to-flow angle was estimated over the systolic part of the cardiac cycle, and its variations were for all measurements larger than the precision of the angle estimation. The range spanned deviations from -25.2° (-6.0 SD) to 23.7° (4.2 SD) with an average deviation from -15.2° to 9.7°. This can significantly affect PSV values measured by SDU as the beam-to-flow angle is not constant and not aligned with the vessel surface. The study demonstrates that the proposed VFI method can be used in vivo for the measurement of PSV in the CCAs, and that angle variations across the cardiac cycle can lead to significant errors in SDU velocity estimates.
Collapse
|
22
|
Avdal J, Ekroll IK, Torp H. Fast Flow-Line-Based Analysis of Ultrasound Spectral and Vector Velocity Estimators. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:372-381. [PMID: 30596573 DOI: 10.1109/tuffc.2018.2887398] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A new technique, termed FLUST (FlowLine Ultrasound Simulation Tool), is proposed as a computationally cheap alternative to simulations based on randomly positioned scatterers for the simulation of stationary blood velocity fields. In FLUST, the flow field is represented as a collection of flow lines. Point spread functions are first calculated at regularly spaced positions along the flow lines before realizations of single scatterers traversing the flow lines are generated using temporal interpolation. Several flow-line realizations are then generated by convolution with temporal noise filters, and finally, flow-field realizations are obtained by the summation of the individual flow-line realizations. Flow-field realizations produced by FLUST are shown to correspond well with conventional Field II simulations both quantitatively and qualitatively. The added value of FLUST is demonstrated by using the proposed simulation technique to obtain multiple realizations of realistic 3-D flow fields at a significantly reduced computational cost. This information is utilized for a performance assessment of different spectral and vector velocity estimators for carotid and coronary imaging applications. The computational load of FLUST does not increase substantially with the number of realizations or simulated frames, and for the examples shown, it is the fastest alternative when the total number of simulated frames exceeds 48. In the examples, the standard deviation and bias of the velocity estimators are calculated using 100 FLUST realizations, in which case the proposed method is two orders of magnitude faster than simulations based on random scatterer positions.
Collapse
|
23
|
Toulemonde M, Li Y, Lin S, Cordonnier F, Butler M, Duncan WC, Eckersley RJ, Sboros V, Tang MX. High-Frame-Rate Contrast Echocardiography Using Diverging Waves: Initial In Vitro and In Vivo Evaluation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2212-2221. [PMID: 30028698 DOI: 10.1109/tuffc.2018.2856756] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Contrast echocardiography (CE) ultrasound with microbubble contrast agents has significantly advanced our capability for assessment of cardiac function, including myocardium perfusion quantification. However, in standard CE techniques obtained with line by line scanning, the frame rate and image quality are limited. Recent research has shown significant frame-rate improvement in noncontrast cardiac imaging. In this work, we present and initially evaluate, both in vitro and in vivo, a high-frame-rate (HFR) CE imaging system using diverging waves and pulse inversion sequence. An imaging frame rate of 5500 frames/s before and 250 frames/s after compounding is achieved. A destruction-replenishment sequence has also been developed. The developed HFR CE is compared with standard CE in vitro on a phantom and then in vivo on a sheep heart. The image signal-to-noise ratio and contrast between the myocardium and the chamber are evaluated. The results show up to 13.4-dB improvement in contrast for HFR CE over standard CE when compared at the same display frame rate even when the average spatial acoustic pressure in HFR CE is 36% lower than the standard CE. It is also found that when coherent compounding is used, the HFR CE image intensity can be significantly modulated by the flow motion in the chamber.
Collapse
|
24
|
Goddi A, Bortolotto C, Raciti MV, Fiorina I, Aiani L, Magistretti G, Sacchi A, Tinelli C, Calliada F. High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:2263-2275. [PMID: 29574932 DOI: 10.1002/jum.14579] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 11/07/2017] [Accepted: 12/09/2017] [Indexed: 06/08/2023]
Abstract
OBJECTIVES To evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. METHODS Carotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. RESULTS Complex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ΔICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (mean ± SD, 47.7 ± 28.5 mm2 ; median, 45.5 mm2 ) compared with color Doppler imaging (mean, 29.2 ± 19.9 mm2 ; median, 29.5 mm2 ) and better depicted different complex flow patterns; a strong correlation (r = 0.84) was found between the ΔICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 ± 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 ± 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r = 0.92). CONCLUSIONS Vector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.
Collapse
Affiliation(s)
- Alfredo Goddi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Chandra Bortolotto
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Maria Vittoria Raciti
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Ilaria Fiorina
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Luca Aiani
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | | | - Andrea Sacchi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Carmine Tinelli
- Clinical Epidemiology and Biometric Unit, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Fabrizio Calliada
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| |
Collapse
|
25
|
Fekkes S, Saris AECM, Nillesen MM, Menssen J, Hansen HHG, de Korte CL. Simultaneous Vascular Strain and Blood Vector Velocity Imaging Using High-Frequency Versus Conventional-Frequency Plane Wave Ultrasound: A Phantom Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1166-1181. [PMID: 29993371 DOI: 10.1109/tuffc.2018.2834724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.
Collapse
|
26
|
Holbek S, Hansen KL, Fogh N, Moshavegh R, Olesen JB, Nielsen MB, Jensen JA. Real-Time 2-D Phased Array Vector Flow Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1205-1213. [PMID: 29993373 DOI: 10.1109/tuffc.2018.2838518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental offline 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner. A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSVs) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow rig with continuous laminar parabolic flow and in a pulsating flow pump system before being tested in vivo, where measurements were obtained on two healthy volunteers. Mean PSV from 11 cycles was 155 cms-1 with a precision of ±9.0% for the pulsating flow pump. In vivo, PSV estimated in the ascending aorta was 135 cms-1 ± 16.9% for eight cardiac cycles. Furthermore, in vivo flow dynamics of the left ventricle and in the ascending aorta were visualized. In conclusion, angle independent 2-D VFI on a phased array has been implemented in real time, and it is capable of providing quantitative and qualitative flow evaluations of both the complex and fully transverse flow.
Collapse
|
27
|
He Y, Shiu YT, Pike DB, Roy-Chaudhury P, Cheung AK, Berceli SA. Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging. J Vasc Surg 2018; 68:1848-1857.e2. [PMID: 29779960 DOI: 10.1016/j.jvs.2018.02.043] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/20/2018] [Indexed: 01/22/2023]
Abstract
OBJECTIVE The objective of this study was to compare blood flow rates measured by Doppler ultrasound (DUS) and phase-contrast magnetic resonance imaging (MRI) in patients having a hemodialysis arteriovenous fistula (AVF) and to identify scenarios in which there was significant discordance between these two approaches. METHODS Blood flow rates in the proximal artery (PA) and draining vein (DV) of newly created upper extremity AVFs were measured and compared using DUS and phase-contrast MRI at 1 day, 6 weeks, and 6 months postoperatively. RESULTS Blood flow rates in the PA measured by DUS (1155 ± 907 mL/min, mean ± standard deviation) and by MRI (1170 ± 657 mL/min) were not statistically different (P = .812) based on 78 data pairs from 49 patients. DV DUS flow (1277 ± 995 mL/min) and MRI flow (1130 ± 655 mL/min) were also not statistically different (P = .071) based on 64 data pairs. In both PA and DV, the two methods substantially agreed with each other (Cohen κ: PA, 0.66; DV, 0.67) when flow rates were put into four clinically relevant categories (<300, 300-599, 600-1499, and ≥1500 mL/min). The Bland-Altman analyses of DUS and MRI flow identified six and four outliers for PA and DV, respectively. Seven outliers had higher DUS than MRI flow, with all DUS scan sites having a large lumen or significant local curvature; the other three had lower DUS flow, partly due to an underestimation of lumen diameter by DUS. CONCLUSIONS DUS and MRI flow rates are generally comparable in both PA and DV. When DUS is used for flow measurements, careful attention to accurate lumen diameter measurements is needed and scan sites with marked curvature should be avoided. Our result may improve the accuracy of DUS-measured AVF blood flow rate.
Collapse
Affiliation(s)
- Yong He
- Department of Surgery, University of Florida, Gainesville, Fla; Malcom Randall VA Medical Center, Gainesville, Fla
| | - Yan-Ting Shiu
- Division of Nephrology & Hypertension, University of Utah, Salt Lake City, Utah
| | - Daniel B Pike
- Department of Bioengineering, University of Utah, Salt Lake City, Utah
| | | | - Alfred K Cheung
- Division of Nephrology & Hypertension, University of Utah, Salt Lake City, Utah; Medical Service, Veterans Affairs Salt Lake City Healthcare System, Salt Lake City, Utah; Department of Nephrology, The Second Xiangya Hospital, Central South University, Changsha, Hunan, People's Republic of China
| | - Scott A Berceli
- Department of Surgery, University of Florida, Gainesville, Fla; Malcom Randall VA Medical Center, Gainesville, Fla.
| |
Collapse
|
28
|
SNR improvement and range side lobe suppression in Golay-encoded Doppler detection for ultrasound high-frequency swept-scan imaging system. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
29
|
Ricci S, Ramalli A, Bassi L, Boni E, Tortoli P. Real-Time Blood Velocity Vector Measurement Over a 2-D Region. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:201-209. [PMID: 29389652 DOI: 10.1109/tuffc.2017.2781715] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Quantitative blood velocity measurements, as currently implemented in commercial ultrasound scanners, are based on pulsed-wave (PW) spectral Doppler and are limited to detect the axial component of the velocity in a single sample volume. On the other hand, vector Doppler methods produce angle-independent estimates by, e.g., combining the frequency shifts measured from different directions. Moreover, thanks to the transmission of plane waves, the investigation of a 2-D region is possible with high temporal resolution, but, unfortunately, the clinical use of these methods is hampered by the massive calculation power required for their real-time execution. In this paper, we present a novel approach based on the transmission of plane waves and the simultaneous reception of echoes from 16 distinct subapertures of a linear array probe, which produces eight lines distributed over a 2-D region. The method was implemented on the ULAO-OP 256 research scanner and tested both in phantom and in vivo. A continuous real-time refresh rate of 36 Hz was achieved in duplex combination with a standard B-mode at pulse repetition frequency of 8 kHz. Accuracies of -11% on velocity and of 2°on angle measurements have been obtained in phantom experiments. Accompanying movies show how the method improves the quantitative measurements of blood velocities and details the flow configurations in the carotid artery of a volunteer.
Collapse
|
30
|
Goddi A, Fanizza M, Bortolotto C, Raciti MV, Fiorina I, He X, Du Y, Calliada F. Vector flow imaging techniques: An innovative ultrasonographic technique for the study of blood flow. JOURNAL OF CLINICAL ULTRASOUND : JCU 2017; 45:582-588. [PMID: 28734035 DOI: 10.1002/jcu.22519] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2017] [Revised: 06/03/2017] [Accepted: 06/09/2017] [Indexed: 06/07/2023]
Abstract
Doppler ultrasonography is routinely used to identify abnormal blood flow. Nevertheless, conventional Doppler can be used to determine only the axial component of blood flow velocity and is angle dependent. A new method of multidimensional angle-independent estimation of flow velocity, called Vector Flow Imaging (VFI), has been proposed. It quantitatively evaluates the true velocity vector's amplitude and direction at any location into a vessel and displays a more intuitive depiction of the flow movements. High frame rate VFI, based on plane wave imaging, allows a detailed dynamic visualization of complex flow by showing even transient events, otherwise undetectable. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:582-588, 2017.
Collapse
Affiliation(s)
- Alfredo Goddi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Marianna Fanizza
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Chandra Bortolotto
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Maria Vittoria Raciti
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Ilaria Fiorina
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Xujin He
- Ultrasound R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Yigang Du
- Ultrasound R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Fabrizio Calliada
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| |
Collapse
|
31
|
Jensen J, Villagomez Hoyos CA, Stuart MB, Ewertsen C, Nielsen MB, Jensen JA. Fast Plane Wave 2-D Vector Flow Imaging Using Transverse Oscillation and Directional Beamforming. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1050-1062. [PMID: 28422656 DOI: 10.1109/tuffc.2017.2693403] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Several techniques can estimate the 2-D velocity vector in ultrasound. Directional beamforming (DB) estimates blood flow velocities with a higher precision and accuracy than transverse oscillation (TO), but at the cost of a high beamforming load when estimating the flow angle. In this paper, it is proposed to use TO to estimate an initial flow angle, which is then refined in a DB step. Velocity magnitude is estimated along the flow direction using cross correlation. It is shown that the suggested TO-DB method can improve the performance of velocity estimates compared with TO, and with a beamforming load, which is 4.6 times larger than for TO and seven times smaller than for conventional DB. Steered plane wave transmissions are employed for high frame rate imaging, and parabolic flow with a peak velocity of 0.5 m/s is simulated in straight vessels at beam-to-flow angles from 45° to 90°. The TO-DB method estimates the angle with a bias and standard deviation (SD) less than 2°, and the SD of the velocity magnitude is less than 2%. When using only TO, the SD of the angle ranges from 2° to 17° and for the velocity magnitude up to 7%. Bias of the velocity magnitude is within 2% for TO and slightly larger but within 4% for TO-DB. The same trends are observed in measurements although with a slightly larger bias. Simulations of realistic flow in a carotid bifurcation model provide visualization of complex flow, and the spread of velocity magnitude estimates is 7.1 cm/s for TO-DB, while it is 11.8 cm/s using only TO. However, velocities for TO-DB are underestimated at peak systole as indicated by a regression value of 0.97 for TO and 0.85 for TO-DB. An in vivo scanning of the carotid bifurcation is used for vector velocity estimations using TO and TO-DB. The SD of the velocity profile over a cardiac cycle is 4.2% for TO and 3.2% for TO-DB.
Collapse
|
32
|
High-frame rate vector flow imaging of the carotid bifurcation. Insights Imaging 2017; 8:319-328. [PMID: 28500487 PMCID: PMC5438320 DOI: 10.1007/s13244-017-0554-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 03/30/2017] [Accepted: 04/13/2017] [Indexed: 11/14/2022] Open
Abstract
Abstract Carotid artery atherosclerotic disease is still a significant cause of cerebrovascular morbidity and mortality. A new angle-independent technique, measuring and visualizing blood flow velocities in all directions, called vector flow imaging (VFI) is becoming available from several vendors. VFI can provide more intuitive and quantitative imaging of vortex formation, which is not clearly distinguishable in the color Doppler image. VFI, as quantitative method assessing disturbed flow patterns of the carotid bifurcation, has the potential to allow better understanding of the diagnostic value of complex flow and to enhance risk stratification. This pictorial review article will show which new information VFI adds for the knowledge of hemodynamics in comparison to the conventional ultrasound techniques. Teaching points • VFI is an angle-independent technique measuring flow velocities in all directions. • This kind of VFI is based on a plane wave multidirectional excitation technique. • VFI allows quantitative assessment of carotid streamlines progression and visualizes vorticity. • VFI does not allow a precise comprehension of streamlines’ 3D shape. • VFI allows a better understanding of carotid artery complex flows. Electronic supplementary material The online version of this article (doi:10.1007/s13244-017-0554-5) contains supplementary material, which is available to authorized users.
Collapse
|
33
|
Ricci S, Swillens A, Ramalli A, Segers P, Tortoli P. Wall Shear Rate Measurement: Validation of a New Method Through Multiphysics Simulations. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:66-77. [PMID: 28092504 DOI: 10.1109/tuffc.2016.2608442] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Wall shear stress is known to affect the vessel endothelial function and to be related to important pathologies like the development of atherosclerosis. It is defined as the product of the blood viscosity by the blood velocity gradient at the wall position, i.e., the wall shear rate (WSR). The WSR measurement is particularly challenging in important cardiovascular sites, like the carotid bifurcation, because of the related complex flow configurations characterized by high spatial and temporal gradients, wall movement, and clutter noise. Moreover, accuracy of any method for WSR measurement can be effectively tested only if reliable gold standard WSR values, considering all the aforementioned disturbing effects, are available. Unfortunately, these requirements are difficult to achieve in a physical phantom, so that the accuracy test of the novel WSR measurement methods was so far limited to straight pipes and/or similar idealistic configurations. In this paper, we propose a new method for WSR measurement and its validation based on a mathematical model of the carotid bifurcation, which, exploiting fluid-structure simulations, is capable of reproducing realistic flow configuration, wall movement, and clutter noise. In particular, the profile near the wall, not directly measurable because affected by clutter, is estimated through a power-law fitting and compared with the gold standard provided by the model. In this condition, the WSR measurements featured an accuracy of ±20 %. A preliminary test on a volunteer confirmed the feasibility of the WSR method for in vivo application.
Collapse
|
34
|
Zhang M, Varray F, Besson A, Carrillo RE, Viallon M, Garcia D, Thiran JP, Friboulet D, Liebgott H, Bernard O. Extension of Fourier-Based Techniques for Ultrafast Imaging in Ultrasound With Diverging Waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:2125-2137. [PMID: 27740480 DOI: 10.1109/tuffc.2016.2616300] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Ultrafast ultrasound imaging has become an intensive area of research thanks to its capability in reaching high frame rates. In this paper, we propose a scheme that allows the extension of the current Fourier-based techniques derived for planar acquisition to the reconstruction of sectorial scan with wide angle using diverging waves. The flexibility of the proposed formulation was assessed through two different Fourier-based techniques. The performance of the derived approaches was evaluated in terms of resolution and contrast from both simulations and in vitro experiments. The comparisons of the current state-of-the-art method with the conventional delay-and-sum technique illustrated the potential of the derived methods for producing competitive results with lower computational complexity.
Collapse
|
35
|
Jensen JA, Nikolov SI, Yu ACH, Garcia D. Ultrasound Vector Flow Imaging-Part I: Sequential Systems. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1704-1721. [PMID: 27824555 DOI: 10.1109/tuffc.2016.2600763] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper gives a review of the most important methods for blood velocity vector flow imaging (VFI) for conventional sequential data acquisition. This includes multibeam methods, speckle tracking, transverse oscillation, color flow mapping derived VFI, directional beamforming, and variants of these. The review covers both 2-D and 3-D velocity estimation and gives a historical perspective on the development along with a summary of various vector flow visualization algorithms. The current state of the art is explained along with an overview of clinical studies conducted and methods for presenting and using VFI. A number of examples of VFI images are presented, and the current limitations and potential solutions are discussed.
Collapse
|
36
|
Yiu BYS, Yu ACH. Least-Squares Multi-Angle Doppler Estimators for Plane-Wave Vector Flow Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1733-1744. [PMID: 27824557 DOI: 10.1109/tuffc.2016.2582514] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Designing robust Doppler vector estimation strategies for use in plane-wave imaging schemes based on unfocused transmissions is a topic that has yet to be studied in depth. One potential solution is to use a multi-angle Doppler estimation approach that computes flow vectors via least-squares fitting, but its performance has not been established. Here, we investigated the efficacy of multi-angle Doppler vector estimators by: 1) comparing its performance with respect to the classical dual-angle (cross-beam) Doppler vector estimator and 2) examining the working effects of multi-angle Doppler vector estimators on flow visualization quality in the context of dynamic flow path rendering. Implementing Doppler vector estimators that use different combinations of transmit (Tx) and receive (Rx) steering angles, our analysis has compared the classical dual-angle Doppler method, a 5-Tx version of dual-angle Doppler, and various multi-angle Doppler configurations based on 3 Tx and 5 Tx. Two angle spans (10°, 20°) were examined in forming the steering angles. In imaging scenarios with known flow profiles (rotating disk and straight-tube parabolic flow), the 3-Tx, 3-Rx and 5-Tx, 5-Rx multi-angle configurations produced vector estimates with smaller variability compared with the dual-angle method, and the estimation results were more consistent with the use of a 20° angle span. Flow vectors derived from multi-angle Doppler estimators were also found to be effective in rendering the expected flow paths in both rotating disk and straight-tube imaging scenarios, while the ones derived from the dual-angle estimator yielded flow paths that deviated from the expected course. These results serve to attest that using multi-angle least-squares Doppler vector estimators, flow visualization can be consistently achieved.
Collapse
|
37
|
Jensen JA, Nikolov SI, Yu ACH, Garcia D. Ultrasound Vector Flow Imaging-Part II: Parallel Systems. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1722-1732. [PMID: 27824556 DOI: 10.1109/tuffc.2016.2598180] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper gives a review of the current state-of-the-art in ultrasound parallel acquisition systems for flow imaging using spherical and plane waves emissions. The imaging methods are explained along with the advantages of using these very fast and sensitive velocity estimators. These experimental systems are capable of acquiring thousands of images per second for fast moving flow as well as yielding the estimates of low velocity flow. These emerging techniques allow the vector flow systems to assess highly complex flow with transitory vortices and moving tissue, and they can also be used in functional ultrasound imaging for studying brain function in animals. This paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed.
Collapse
|
38
|
Holbek S, Christiansen TL, Stuart MB, Beers C, Thomsen EV, Jensen JA. 3-D Vector Flow Estimation With Row-Column-Addressed Arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1799-1814. [PMID: 27824562 DOI: 10.1109/tuffc.2016.2582536] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Simulation and experimental results from 3-D vector flow estimations for a 62 + 62 2-D row-column (RC) array with integrated apodization are presented. A method for implementing a 3-D transverse oscillation (TO) velocity estimator on a 3-MHz RC array is developed and validated. First, a parametric simulation study is conducted, where flow direction, ensemble length, number of pulse cycles, steering angles, transmit/receive apodization, and TO apodization profiles and spacing are varied, to find the optimal parameter configuration. The performance of the estimator is evaluated with respect to relative mean bias ~B and mean standard deviation ~σ . Second, the optimal parameter configuration is implemented on the prototype RC probe connected to the experimental ultrasound scanner SARUS. Results from measurements conducted in a flow-rig system containing a constant laminar flow and a straight-vessel phantom with a pulsating flow are presented. Both an M-mode and a steered transmit sequence are applied. The 3-D vector flow is estimated in the flow rig for four representative flow directions. In the setup with 90° beam-to-flow angle, the relative mean bias across the entire velocity profile is (-4.7, -0.9, 0.4)% with a relative standard deviation of (8.7, 5.1, 0.8)% for ( vx, vy, vz ). The estimated peak velocity is 48.5 ± 3 cm/s giving a -3% bias. The out-of-plane velocity component perpendicular to the cross section is used to estimate volumetric flow rates in the flow rig at a 90° beam-to-flow angle. The estimated mean flow rate in this setup is 91.2 ± 3.1 L/h corresponding to a bias of -11.1%. In a pulsating flow setup, flow rate measured during five cycles is 2.3 ± 0.1 mL/stroke giving a negative 9.7% bias. It is concluded that accurate 3-D vector flow estimation can be obtained using a 2-D RC-addressed array.
Collapse
|
39
|
Hussain B, Yiu BYS, Yu ACH, Lacefield JC, Poepping TL. Investigation of Crossbeam Multi-receiver Configurations for Accurate 3-D Vector Doppler Velocity Estimation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1786-1798. [PMID: 27824561 DOI: 10.1109/tuffc.2016.2597135] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
An accurate estimation of low blood velocities whose Doppler shifts span the wall filter cutoff, such as near the wall in recirculation or disturbed flow regions, is important for accurate mapping of velocities to achieve improved estimations of wall shear stress and turbulence, which are known risk factors for atherosclerosis and stroke. This paper presents the comparative benefit of increasing the number of receiver beams above three for an improved estimation of low 3-D velocities. The 3-D crossbeam vector Doppler ultrasound configurations were studied in terms of the number of receiver beams, interbeam angle, and beam selection method (criterion for discriminating between tissue and blood Doppler signals) for a range of velocity orientations, which may prove useful in the design of a future 2-D array for vascular imaging. For maximum velocity resolution, a shallow gradient of low flow velocities up to 5 cm/s was generated across a large-diameter (2.46 cm) straight vessel. Data were acquired using a linear array rotated around the central transmit beam axis to generate three- to eight-receiver (3R-8R) configurations;the rotation of each configuration relative to the flow axis was used to mimic a broad range of velocity vector orientations. Accuracy and precision for ≥5 receivers were consistently better over all velocity orientations and for all selection methods. For a velocity magnitude of 2 cm/s, the best accuracy and precision in both magnitude and direction (~21% ± 13%, <1° ± 9°, respectively) were seen with a 5R configuration using a weighted least-squares selection method. Asymmetry in the 5R configuration led to an improved accuracy and precision compared with that in symmetrical 6R and 8R configurations. The results demonstrated relatively little to no benefit from more than five receiver beams.
Collapse
|
40
|
Boni E, Bassi L, Dallai A, Guidi F, Meacci V, Ramalli A, Ricci S, Tortoli P. ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1488-1495. [PMID: 27187952 PMCID: PMC7115910 DOI: 10.1109/tuffc.2016.2566920] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Open scanners offer an increasing support to the ultrasound researchers who are involved in the experimental test of novel methods. Each system presents specific performance in terms of number of channels, flexibility, processing power, data storage capability, and overall dimensions. This paper reports the design criteria and hardware/software implementation details of a new 256-channel ultrasound advanced open platform. This system is organized in a modular architecture, including multiple front-end boards, interconnected by a high-speed (80 Gb/s) ring, capable of finely controlling all transmit (TX) and receive (RX) signals. High flexibility and processing power (equivalent to 2500 GFLOP) are guaranteed by the possibility of individually programming multiple digital signal processors and field programmable gate arrays. Eighty GB of on-board memory are available for the storage of prebeamforming, postbeamforming, and baseband data. The use of latest generation devices allowed to integrate all needed electronics in a small size ( 34 cm ×30 cm ×26 cm). The system implements a multiline beamformer that allows obtaining images of 96 lines by 2048 depths at a frame rate of 720 Hz (expandable to 3000 Hz). The multiline beamforming capability is also exploited to implement a real-time vector Doppler scheme in which a single TX and two independent RX apertures are simultaneously used to maintain the analysis over a full pulse repetition frequency range.
Collapse
|
41
|
Posada D, Poree J, Pellissier A, Chayer B, Tournoux F, Cloutier G, Garcia D. Staggered Multiple-PRF Ultrafast Color Doppler. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:1510-1521. [PMID: 26780789 DOI: 10.1109/tmi.2016.2518638] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.
Collapse
|
42
|
Xu C, Yuan C, Stutzman E, Canton G, Comess KA, Beach KW. Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:699-716. [PMID: 26705891 PMCID: PMC4744121 DOI: 10.1016/j.ultrasmedbio.2015.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Revised: 10/05/2015] [Accepted: 11/02/2015] [Indexed: 06/05/2023]
Abstract
The Bernoulli effect may result in eruption of a vulnerable carotid atheroma, causing a stroke. We measured electrocardiography (ECG)-registered QRS intra-stenotic blood velocity and atheroma strain dynamics in carotid artery walls using ultrasonic tissue Doppler methods, providing displacement and time resolutions of 0.1 μm and 3.7 ms. Of 22 arteries, 1 had a peak systolic velocity (PSV) >280 cm/s, 4 had PSVs between 165 and 280 cm/s and 17 had PSVs <165 cm/s. Eight arteries with PSVs <65 cm/s and 4 of 9 with PSVs between 65 and 165 cm/s had normal systolic diametric expansion (0% and 7%) and corresponding systolic wall thinning. The remaining 10 arteries had abnormal systolic strain dynamics, 2 with diametric reduction (>-0.05 mm), 2 with extreme wall expansion (>0.1 mm), 2 with extreme wall thinning (>-0.1 mm) and 4 with combinations. Decreases in systolic diameter and/or extreme systolic arterial wall thickening may indicate imminent atheroma rupture.
Collapse
Affiliation(s)
- Canxing Xu
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Chun Yuan
- Department of Bioengineering, University of Washington, Seattle, Washington, USA; Department of Radiology, Vascular Imaging Laboratory, University of Washington, Seattle, Washington, USA
| | - Edward Stutzman
- D. E. Strandness, Jr. Vascular Laboratory, University of Washington Medical Center, Seattle, Washington, USA
| | - Gador Canton
- Department of Radiology, Vascular Imaging Laboratory, University of Washington, Seattle, Washington, USA
| | | | - Kirk W Beach
- Department of Bioengineering, University of Washington, Seattle, Washington, USA; Department of Radiology, Vascular Imaging Laboratory, University of Washington, Seattle, Washington, USA; Department of Surgery, University of Washington, Seattle, Washington, USA.
| |
Collapse
|
43
|
Leow CH, Bazigou E, Eckersley RJ, Yu ACH, Weinberg PD, Tang MX. Flow Velocity Mapping Using Contrast Enhanced High-Frame-Rate Plane Wave Ultrasound and Image Tracking: Methods and Initial in Vitro and in Vivo Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2913-2925. [PMID: 26275971 DOI: 10.1016/j.ultrasmedbio.2015.06.012] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Revised: 04/22/2015] [Accepted: 06/16/2015] [Indexed: 06/04/2023]
Abstract
Ultrasound imaging is the most widely used method for visualising and quantifying blood flow in medical practice, but existing techniques have various limitations in terms of imaging sensitivity, field of view, flow angle dependence, and imaging depth. In this study, we developed an ultrasound imaging velocimetry approach capable of visualising and quantifying dynamic flow, by combining high-frame-rate plane wave ultrasound imaging, microbubble contrast agents, pulse inversion contrast imaging and speckle image tracking algorithms. The system was initially evaluated in vitro on both straight and carotid-mimicking vessels with steady and pulsatile flows and in vivo in the rabbit aorta. Colour and spectral Doppler measurements were also made. Initial flow mapping results were compared with theoretical prediction and reference Doppler measurements and indicate the potential of the new system as a highly sensitive, accurate, angle-independent and full field-of-view velocity mapping tool capable of tracking and quantifying fast and dynamic flows.
Collapse
Affiliation(s)
- Chee Hau Leow
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Eleni Bazigou
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Robert J Eckersley
- Department of Biomedical Engineering, King's College London, London, United Kingdom
| | - Alfred C H Yu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Peter D Weinberg
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Meng-Xing Tang
- Department of Bioengineering, Imperial College London, London, United Kingdom.
| |
Collapse
|
44
|
Fadnes S, Ekroll IK, Nyrnes SA, Torp H, Lovstakken L. Robust angle-independent blood velocity estimation based on dual-angle plane wave imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1757-67. [PMID: 26470038 DOI: 10.1109/tuffc.2015.007108] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Two-dimensional blood velocity estimation has shown potential to solve the angle-dependency of conventional ultrasound flow imaging. Clutter filtering, however, remains a major challenge for large beam-to-flow angles, leading to signal drop-outs and corrupted velocity estimates. This work presents and evaluates a compounding speckle tracking (ST) algorithm to obtain robust angle-independent 2-D blood velocity estimates for all beam-to-flow angles. A dual-angle plane wave imaging setup with full parallel receive beamforming is utilized to achieve high-frame-rate speckle tracking estimates from two scan angles, which may be compounded to obtain velocity estimates of increased robustness. The acquisition also allows direct comparison with vector Doppler (VD) imaging. Absolute velocity bias and root-mean-square (RMS) error of the compounding ST estimations were investigated using simulations of a rotating flow phantom with low velocities ranging from 0 to 20 cm/s. In a challenging region where the estimates were influenced by clutter filtering, the bias and RMS error for the compounding ST estimates were 11% and 2 cm/s, a significant reduction compared with conventional single-angle ST (22% and 4 cm/s) and VD (36% and 6 cm/s). The method was also tested in vivo for vascular and neonatal cardiac imaging. In a carotid artery bifurcation, the obtained blood velocity estimates showed that the compounded ST method was less influenced by clutter filtering than conventional ST and VD methods. In the cardiac case, it was observed that ST velocity estimation is more affected by low signal-to-noise (SNR) than VD. However, with sufficient SNR the in vivo results indicated that a more robust angle-independent blood velocity estimator is obtained using compounded speckle tracking compared with conventional ST and VD methods.
Collapse
|
45
|
Kadowaki H, Hayase T, Funamoto K, Taniguchi N. Study of Estimation Method for Unsteady Inflow Velocity in Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Simulation. IEEE Trans Biomed Eng 2015; 63:403-14. [PMID: 26241967 DOI: 10.1109/tbme.2015.2461559] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Information on hemodynamics is essential for elucidation of mechanisms and development of novel diagnostic methods for circulatory diseases. Two-dimensional ultrasonic-measurement-integrated (2D-UMI) simulation can correctly reproduce an intravascular blood flow field and hemodynamics by feeding back an ultrasonic measurement to the numerical blood flow simulation. In this method, it is critically important to give the correct cross-sectional average inflow velocity (inflow velocity) as the boundary condition. However, systematic study has not been done on the relative validity and effectiveness of existing inflow velocity estimation methods for various target flow fields. The aim of this study was to examine the existing methods systematically and to establish a method to accurately estimate inflow velocities for various vessel geometries and flow conditions in 2D-UMI simulations. A numerical experiment was performed for 2D-UMI simulation of blood flow models in a straight vessel with inflow velocity profiles symmetric and asymmetric to the vessel axis using existing evaluation functions based on Doppler velocity error for the inflow velocity estimation. As a result, it was clarified that a significantly large estimation error occurs in the asymmetric flow due to a nonfeedback domain near the downstream end of the calculation domain. Hence, a new inflow velocity estimation method of 2D-UMI simulation is proposed in which the feedback and evaluation domains are extended to the downstream end. Further numerical experiments of 2D-UMI simulation for two realistic vessel geometries of a healthy blood vessel and a stenosed one confirmed the effectiveness of the proposed method.
Collapse
|
46
|
Tortoli P, Lenge M, Righi D, Ciuti G, Liebgott H, Ricci S. Comparison of carotid artery blood velocity measurements by vector and standard Doppler approaches. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1354-1362. [PMID: 25722028 DOI: 10.1016/j.ultrasmedbio.2015.01.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 12/22/2014] [Accepted: 01/16/2015] [Indexed: 06/04/2023]
Abstract
Although severely affected by the angle dependency, carotid artery peak systolic velocity measurements are widely used for assessment of stenosis. In this study, blood peak systolic velocities in the common and internal carotid arteries of both healthy volunteers and patients with internal carotid artery stenosis were measured by two vector Doppler (VD) methods and compared with measurements obtained with the conventional spectral Doppler approach. Although the two VD techniques were completely different (using the transmission of focused beams and plane waves, respectively), the measurement results indicate that these techniques are nearly equivalent. The peak systolic velocities measured in 22 healthy common carotid arteries by the two VD techniques were very close (according to Bland-Altman analysis, the average difference was 3.2%, with limits of agreement of ± 8.6%). Application of Bland-Altman analysis to comparison of either VD technique with the spectral Doppler method provided a 21%-25% average difference with ± 13%-15% limits of agreement. Analysis of the results obtained from 15 internal carotid arteries led to similar conclusions, indicating significant overestimation of peak systolic velocity with the spectral Doppler method. Inter- and intra-operator repeatability measurements performed in a group of 8 healthy volunteers provided equivalent results for all of the methods (coefficients of variability in the range 2.7%-6.9%), even though the sonographers were not familiar with the VD methods. The results of this study suggest that the introduction of vector Doppler methods in commercial machines may finally be considered mature and capable of overcoming the angle-dependent overestimation typical of the standard spectral Doppler approach.
Collapse
Affiliation(s)
- Piero Tortoli
- Department of Information Engineering, Università degli Studi di Firenze, Florence, Italy.
| | - Matteo Lenge
- Department of Information Engineering, Università degli Studi di Firenze, Florence, Italy; CREATIS, Université de Lyon 1, CNRS UMR 5220, INSERM U1044, INSA, Lyon, France
| | - Daniele Righi
- Heart and Vessels Department, AOU Careggi, Florence, Italy
| | - Gabriele Ciuti
- Heart and Vessels Department, AOU Careggi, Florence, Italy
| | - Hervé Liebgott
- CREATIS, Université de Lyon 1, CNRS UMR 5220, INSERM U1044, INSA, Lyon, France
| | - Stefano Ricci
- Department of Information Engineering, Università degli Studi di Firenze, Florence, Italy
| |
Collapse
|
47
|
Ricci S, Vilkomerson D, Matera R, Tortoli P. Accurate blood peak velocity estimation using spectral models and vector doppler. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:686-696. [PMID: 25881346 DOI: 10.1109/tuffc.2015.006982] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Ultrasound blood peak velocity estimates are routinely used for diagnostics, such as the grading of a stenosis. The peak velocity is typically assessed from the Doppler spectrum by locating the highest frequency detectable from noise. The selected frequency is then converted to velocity by the Doppler equation. This procedure contains several potential sources of error: the frequency selection is noise dependent and sensitive to the spectral broadening, which, in turn, is affected by the Doppler angle uncertainty. The result is, often, an inaccurate estimate. In this work we propose a new method that removes the aforementioned errors. The frequency is selected by exploiting a mathematical model of the Doppler spectrum that has recently been introduced. When a very large sample volume is used, which includes all the vessel section, the model is capable of predicting the exact threshold to be used without the need of broadening compensation. The angle ambiguity is solved by applying the threshold to the Doppler spectra measured from two different directions, according to the vector Doppler technique. The proposed approach has here been validated through Field II simulations, phantom experiments, and tests on volunteers by using defocused waves to insonify a large region from a linear array probe. A mean error lower than 1% and a mean coefficient of variability lower than 5% were measured in a variety of experimental conditions.
Collapse
|
48
|
Hoskins PR, Kenwright DA. Recent developments in vascular ultrasound technology. ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2015; 23:158-65. [PMID: 27433252 DOI: 10.1177/1742271x15578778] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
This article describes four technologies relevant to vascular ultrasound which are available commercially in 2015, and traces their origin back through the research literature. The technologies are 3D ultrasound and its use in plaque volume estimation (first described in 1994), colour vector Doppler for flow visualisation (1994), wall motion for estimation of arterial stiffness (1968), and shear wave elastography imaging of the arterial wall (2010). Overall these technologies have contributed to the understanding of vascular disease but have had little impact on clinical practice. The basic toolkit for vascular ultrasound has for the last 25 years been real-time B-mode, colour flow and spectral Doppler. What has changed over this time is improvement in image quality. Looking ahead it is noted that 2D array transducers and high frame rate imaging continue to spread through the commercial vascular ultrasound sector and both have the potential to impact on clinical practice.
Collapse
Affiliation(s)
- P R Hoskins
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, EH16 4TJ
| | - D A Kenwright
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, EH16 4TJ
| |
Collapse
|
49
|
Ricci S, Matera R, Tortoli P. An improved Doppler model for obtaining accurate maximum blood velocities. ULTRASONICS 2014; 54:2006-2014. [PMID: 24934798 DOI: 10.1016/j.ultras.2014.05.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 05/15/2014] [Accepted: 05/15/2014] [Indexed: 06/03/2023]
Abstract
Maximum blood velocity estimates are frequently required in diagnostic applications, including carotid stenosis evaluation, arteriovenous fistula inspection, and maternal-fetal examinations. However, the currently used methods for ultrasound measurements are inaccurate and often rely on applying heuristic thresholds to a Doppler power spectrum. A new method that uses a mathematical model to predict the correct threshold that should be used for maximum velocity measurements has recently been introduced. Although it is a valuable and deterministic tool, this method is limited to parabolic flows insonated by uniform pressure fields. In this work, a more generalized technique that overcomes such limitations is presented. The new approach, which uses an extended Doppler spectrum model, has been implemented in an experimental set-up based on a linear array probe that transmits defocused steered waves. The improved model has been validated by Field II simulations and phantom experiments on tubes with diameters between 2mm and 8mm. Using the spectral threshold suggested by the new model significantly higher accuracy estimates of the peak velocity can be achieved than are now clinically attained, including for narrow beams and non-parabolic velocity profiles. In particular, an accuracy of +1.2±2.5 cm/s has been obtained in phantom measurements for velocities ranging from 20 to 80 cm/s. This result represents an improvement that can significantly affect the way maximum blood velocity is investigated today.
Collapse
Affiliation(s)
- Stefano Ricci
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy.
| | - Riccardo Matera
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy
| | - Piero Tortoli
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy
| |
Collapse
|
50
|
Lenge M, Ramalli A, Boni E, Liebgott H, Cachard C, Tortoli P. High-frame-rate 2-D vector blood flow imaging in the frequency domain. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1504-1514. [PMID: 25167150 DOI: 10.1109/tuffc.2014.3064] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Conventional ultrasound Doppler techniques estimate the blood velocity exclusively in the axial direction to produce the sonograms and color flow maps needed for diagnosis of cardiovascular diseases. In this paper, a novel method to produce bi-dimensional maps of 2-D velocity vectors is proposed. The region of interest (ROI) is illuminated by plane waves transmitted at the pulse repetition frequency (PRF) in a fixed direction. For each transmitted plane wave, the backscattered echoes are recombined offline to produce the radio-frequency image of the ROI. The local 2-D phase shifts between consecutive speckle images are efficiently estimated in the frequency domain, to produce vector maps up to 15 kHz PRF. Simulations and in vitro steady-flow experiments with different setup conditions have been conducted to thoroughly evaluate the method's performance. Bias is proved to be lower than 10% in most simulations and lower than 20% in experiments. Further simulations and in vivo experiments have been made to test the approach's feasibility in pulsatile flow conditions. It has been estimated that the computation of the frequency domain algorithm is more than 50 times faster than the computation of the reference 2-D cross-correlation algorithm.
Collapse
|