1
|
Wu YC, Xu GX, Chen C, Chuang YH, Huang CC. Estimating the viscoelastic anisotropy of human skin through high-frequency ultrasound elastography. Med Phys 2024. [PMID: 39225581 DOI: 10.1002/mp.17372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 08/10/2024] [Accepted: 08/11/2024] [Indexed: 09/04/2024] Open
Abstract
BACKGROUND The skin is the largest organ of the human body and serves distinct functions in protecting the body. The viscoelastic properties of the skin play a key role in supporting the skin-healing process, also it may be changed due to some skin diseases. PROPOSE In this study, high-frequency ultrasound (HFUS) elastography based on a Lamb wave model was used to noninvasively assess the viscoelastic anisotropy of human skin. METHOD Elastic waves were generated through an external vibrator, and the wave propagation velocity was measured through 40 MHz ultrafast HFUS imaging. Through the use of a thin-layer gelatin phantom, HFUS elastography was verified to produce highly accurate estimates of elasticity and viscosity. In a human study involving five volunteers, viscoelastic anisotropy was assessed by rotating an ultrasound transducer 360°. RESULTS An oval-shaped pattern in the elasticity of human forearm skin was identified, indicating the high elastic anisotropy of skin; the average elastic moduli were 24.90 ± 6.63 and 13.64 ± 2.67 kPa along and across the collagen fiber orientation, respectively. The average viscosity of all the recruited volunteers was 3.23 ± 0.93 Pa·s. CONCLUSIONS Although the examined skin exhibited elastic anisotropy, no evident viscosity anisotropy was observed.
Collapse
Affiliation(s)
- Yu-Chen Wu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Guo-Xuan Xu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chien Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Yi-Hsiang Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
2
|
Billy J, Bensamoun SF, Mercier J, Durand S. Applications of ultrasound elastography to hand and upper limb disorders. HAND SURGERY & REHABILITATION 2024; 43:101636. [PMID: 38215880 DOI: 10.1016/j.hansur.2024.101636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/22/2023] [Accepted: 12/24/2023] [Indexed: 01/14/2024]
Abstract
Ultrasound elastography is a recently developed method for accurate measurement of soft tissue stiffness in addition to the clinician's subjective evaluation. The present review briefly describes the ultrasound elastography techniques and outlines clinical applications for tendon, muscle, nerve, skin and other soft tissues of the hand and upper limb. Strain elastography provides a qualitative evaluation of the stiffness, and shear-wave elastography generates quantitative elastograms superimposed on a B-mode image. The stiffness in degenerative tendinopathy and/or tendon injury was significantly lower than in a normal tendon in several studies. Elastography is also a reliable method to evaluate functional muscle activity, compared to conventional surface electromyography. The median nerve is consistently stiffer in patients with carpal tunnel syndrome than in healthy subjects, on whatever ultrasound elastography technique. Elastography distinguishes normal skin from scars and can be used to evaluate scar severity and treatment. Elastography has huge clinical applications in musculoskeletal tissues. Continued development of systems and increased training of clinicians will expand our knowledge of elastography and its clinical applications in the future.
Collapse
Affiliation(s)
- Jessica Billy
- Department of Hand Surgery, Lausanne University Hospital, University of Lausanne, 1011 Lausanne, Switzerland
| | - Sabine F Bensamoun
- Sorbonne University, Université de Technologie de Compiègne, CNRS UMR 7338, Biomechanics and Bioengineering, Compiègne, France
| | - Julie Mercier
- Department of Hand Surgery, Lausanne University Hospital, University of Lausanne, 1011 Lausanne, Switzerland
| | - Sébastien Durand
- Department of Hand Surgery, Lausanne University Hospital, University of Lausanne, 1011 Lausanne, Switzerland.
| |
Collapse
|
3
|
Xu GX, Chen PY, Huang CC. Visualization of Human Hand Tendon Mechanical Anisotropy in 3-D Using High- Frequency Dual-Direction Shear Wave Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1457-1469. [PMID: 37669211 DOI: 10.1109/tuffc.2023.3312273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/07/2023]
Abstract
High-resolution ultrasound shear wave elastography has been used to determine the mechanical properties of hand tendons. However, because of fiber orientation, tendons have anisotropic properties; this results in differences in shear wave velocity (SWV) between ultrasound scanning cross sections. Rotating transducers can be used to achieve full-angle scanning. However, this technique is inconvenient to implement in clinical settings. Therefore, in this study, high-frequency ultrasound (HFUS) dual-direction shear wave imaging (DDSWI) based on two external vibrators was used to create both transverse and longitudinal shear waves in the human flexor carpi radialis tendon. SWV maps from two directions were obtained using 40-MHz ultrafast imaging at the same scanning cross section. The anisotropic map was calculated pixel by pixel, and 3-D information was obtained using mechanical scanning. A standard phantom experiment was then conducted to verify the performance of the proposed HFUS DDSWI technique. Human studies were also conducted where volunteers assumed three hand postures: relaxed (Rel), full fist (FF), and tabletop (TT). The experimental results indicated that both the transverse and longitudinal SWVs increased due to tendon flexion. The transverse SWV surpassed the longitudinal SWV in all cases. The average anisotropic ratios for the Rel, FF, and TT hand postures were 1.78, 2.01, and 2.21, respectively. Both the transverse and the longitudinal SWVs were higher at the central region of the tendon than at the surrounding region. In conclusion, the proposed HFUS DDSWI technique is a high-resolution imaging technique capable of characterizing the anisotropic properties of tendons in clinical applications.
Collapse
|
4
|
Kumar A, Kempski Leadingham KM, Kerensky MJ, Sankar S, Thakor NV, Manbachi A. Visualizing tactile feedback: an overview of current technologies with a focus on ultrasound elastography. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 5:1238129. [PMID: 37854637 PMCID: PMC10579802 DOI: 10.3389/fmedt.2023.1238129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 09/14/2023] [Indexed: 10/20/2023] Open
Abstract
Tissue elasticity remains an essential biomarker of health and is indicative of irregularities such as tumors or infection. The timely detection of such abnormalities is crucial for the prevention of disease progression and complications that arise from late-stage illnesses. However, at both the bedside and the operating table, there is a distinct lack of tactile feedback for deep-seated tissue. As surgical techniques advance toward remote or minimally invasive options to reduce infection risk and hasten healing time, surgeons lose the ability to manually palpate tissue. Furthermore, palpation of deep structures results in decreased accuracy, with the additional barrier of needing years of experience for adequate confidence of diagnoses. This review delves into the current modalities used to fulfill the clinical need of quantifying physical touch. It covers research efforts involving tactile sensing for remote or minimally invasive surgeries, as well as the potential of ultrasound elastography to further this field with non-invasive real-time imaging of the organ's biomechanical properties. Elastography monitors tissue response to acoustic or mechanical energy and reconstructs an image representative of the elastic profile in the region of interest. This intuitive visualization of tissue elasticity surpasses the tactile information provided by sensors currently used to augment or supplement manual palpation. Focusing on common ultrasound elastography modalities, we evaluate various sensing mechanisms used for measuring tactile information and describe their emerging use in clinical settings where palpation is insufficient or restricted. With the ongoing advancements in ultrasound technology, particularly the emergence of micromachined ultrasound transducers, these devices hold great potential in facilitating early detection of tissue abnormalities and providing an objective measure of patient health.
Collapse
Affiliation(s)
- Avisha Kumar
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
- HEPIUS Innovation Lab, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Kelley M. Kempski Leadingham
- HEPIUS Innovation Lab, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Max J. Kerensky
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
- HEPIUS Innovation Lab, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Sriramana Sankar
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Nitish V. Thakor
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Amir Manbachi
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
- HEPIUS Innovation Lab, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| |
Collapse
|
5
|
Vo MHT, Lin CJ, Chieh HF, Kuo LC, An KN, Wang YL, Su FC. Behavior of medial gastrocnemius muscle beneath kinesio taping during isometric contraction and badminton lunge performance after fatigue induction. Sci Rep 2023; 13:1779. [PMID: 36720990 PMCID: PMC9889375 DOI: 10.1038/s41598-023-28818-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 01/25/2023] [Indexed: 02/02/2023] Open
Abstract
Kinesio taping (KT) is widely used in sports for performance improvement and injury prevention. However, little is known of the behavior of the muscle region beneath the KT with movement, particularly when the muscle is fatigued. Accordingly, this study investigated the changes in the medial gastrocnemius muscle architecture and fascia thickness when using KT during maximum isometric plantar flexion (MVIC) and badminton lunges following heel rise exercises performed to exhaustion. Eleven healthy collegiate badminton players (4 males and 7 females) were recruited. All of the participants performed two tasks (MVIC and badminton lunge) with a randomized sequence of no taping, KT and sham taping and repeated following exhaustive repetitive heel rise exercise. In the MVIC task, the fascia thickness with the medial gastrocnemius muscle at rest significantly decreased following fatigue induction both without taping and with KT and sham taping (p = 0.036, p = 0.028 and p = 0.025, respectively). In the lunge task, the fascia thickness reduced after fatigue induction in the no taping and sham taping trials; however, no significant change in the fascia thickness occurred in the KT trials. Overall, the results indicate that KT provides a better effect during dynamic movement than in isometric contraction.
Collapse
Affiliation(s)
- Minh Hoang-Thuc Vo
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chien-Ju Lin
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Hsiao-Feng Chieh
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Li-Chieh Kuo
- Department of Occupational Therapy, National Cheng Kung University, Tainan, Taiwan
| | - Kai-Nan An
- Division of Orthopedic Research, Mayo Clinic, Rochester, USA
| | - Yu-Lin Wang
- Department of Rehabilitation, Chi Mei Medical Center, Tainan, Taiwan
| | - Fong-Chin Su
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
6
|
Dong Z, Kim J, Huang C, Lowerison MR, Lok UW, Chen S, Song P. Three-Dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array. BME FRONTIERS 2022; 2022:9879632. [PMID: 37850186 PMCID: PMC10521701 DOI: 10.34133/2022/9879632] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 05/18/2022] [Indexed: 10/19/2023] Open
Abstract
Objective. To develop a 3D shear wave elastography (SWE) technique using a 2D row column addressing (RCA) array, with either external vibration or acoustic radiation force (ARF) as the shear wave source. Impact Statement. The proposed method paves the way for clinical translation of 3D SWE based on the 2D RCA, providing a low-cost and high volume rate solution that is compatible with existing clinical systems. Introduction. SWE is an established ultrasound imaging modality that provides a direct and quantitative assessment of tissue stiffness, which is significant for a wide range of clinical applications including cancer and liver fibrosis. SWE requires high frame rate imaging for robust shear wave tracking. Due to the technical challenges associated with high volume rate imaging in 3D, current SWE techniques are typically confined to 2D. Advancing SWE from 2D to 3D is significant because of the heterogeneous nature of tissue, which demands 3D imaging for accurate and comprehensive evaluation. Methods. A 3D SWE method using a RCA array was developed with a volume rate up to 2000 Hz. The performance of the proposed method was systematically evaluated on tissue-mimicking elasticity phantoms and in an in vivo case study. Results. 3D shear wave motion induced by either external vibration or ARF was successfully detected with the proposed method. Robust 3D shear wave speed maps were reconstructed for phantoms and in vivo. Conclusion. The high volume rate 3D imaging provided by the 2D RCA array provides a robust and practical solution for 3D SWE with a clear pathway for future clinical translation.
Collapse
Affiliation(s)
- Zhijie Dong
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
| | - Jihun Kim
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
- Division of ICT Convergence Engineering/Major in Electronic Engineering, Kangnam University, Republic of Korea
| | - Chengwu Huang
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Matthew R. Lowerison
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
| | - U-Wai Lok
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Shigao Chen
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Pengfei Song
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
7
|
Chen W, Zhang Q, Liu J, Lei S, Li Y, Huang J, Guo L, Zheng H, Wu D, Ma T. Design and Fabrication of a High-Frequency Microconvex Array Transducer for Small Animals Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1943-1951. [PMID: 35073263 DOI: 10.1109/tuffc.2022.3146309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
High-frequency convex array transducer, featuring both high spatial resolution and wide field of view, has been successfully developed for ophthalmic imaging. To further expand its application range to small animals' imaging, this work develops a high-frequency microconvex array transducer possessing smaller aperture size and wider scanning angle. This transducer featured 128 array elements arranged in a curvilinear 2-2 piezoelectric composite configuration, yielding a maximum view angle of 97.8°. The array was composed of two front matching layers, a nonconductive backing layer, and a customized flexible circuit that electrically connected array elements to coaxial cables. The center frequency and the -6-dB fractional bandwidth were about 18.14 MHz and 69.15%, respectively. The image of a tungsten wire phantom resulted in approximately 62.9- [Formula: see text] axial resolution and 121.3- [Formula: see text] lateral resolution. The image of the whole kidney of a rat as well as its internal arteries was acquired in vivo, demonstrating the imaging capability of the proposed high-frequency microconvex array transducers for small animals' imaging applications.
Collapse
|
8
|
Lu JY, Lee PY, Huang CC. Improving Image Quality for Single-Angle Plane Wave Ultrasound Imaging With Convolutional Neural Network Beamformer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1326-1336. [PMID: 35175918 DOI: 10.1109/tuffc.2022.3152689] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Ultrafast ultrasound imaging based on plane wave (PW) compounding has been proposed for use in various clinical and preclinical applications, including shear wave imaging and super resolution blood flow imaging. Because the image quality afforded by PW imaging is highly dependent on the number of PW angles used for compounding, a tradeoff between image quality and frame rate occurs. In the present study, a convolutional neural network (CNN) beamformer based on a combination of the GoogLeNet and U-Net architectures was developed to replace the conventional delay-and-sum (DAS) algorithm to obtain high-quality images at a high frame rate. RF channel data are used as the inputs for the CNN beamformers. The outputs are in-phase and quadrature data. Simulations and phantom experiments revealed that the images predicted by the CNN beamformers had higher resolution and contrast than those predicted by conventional single-angle PW imaging with the DAS approach. In in vivo studies, the contrast-to-noise ratios (CNRs) of carotid artery images predicted by the CNN beamformers using three or five PWs as ground truths were approximately 12 dB in the transverse view, considerably higher than the CNR obtained using the DAS beamformer (3.9 dB). Most tissue speckle information was retained in the in vivo images produced by the CNN beamformers. In conclusion, only a single PW at 0° was fired, but the quality of the output image was proximal to that of an image generated using three or five PW angles. In other words, the quality-frame rate tradeoff of coherence compounding could be mitigated through the use of the proposed CNN for beamforming.
Collapse
|
9
|
Xu GX, Chen PY, Jiang X, Huang CC. Visualization of Human Skeletal Muscle Anisotropy by Using Dual-Direction Shear Wave Imaging. IEEE Trans Biomed Eng 2022; 69:2745-2754. [PMID: 35192460 DOI: 10.1109/tbme.2022.3152896] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Ultrasound (US) shear wave elasticity imaging (SWEI) is a mature technique for diagnosing the elasticity of isotropic tissues. However, the elasticity of anisotropic tissues, such as muscle and tendon, cannot be diagnosed correctly using SWEI because the shear wave velocity (SWV) varies with tissue fiber orientations. Recently, SWEI has been studied for measuring the anisotropic properties of muscles by rotating the transducer; however, this is difficult for clinical practice. METHODS In this study, a novel dual-direction shear wave imaging (DDSWI) technique was proposed for visualizing the mechanical anisotropy of muscles without rotation. Longitudinal and transverse shear waves were created by a specially designed external vibrator and supersonic pushing beam, respectively; the SWVs were then tracked using ultrafast US imaging. Subsequently, the SWV maps of two directions were obtained at the same scanning cross section, and the mechanical anisotropy was represented as the ratio between them at each pixel. RESULTS The performance of DDSWI was verified using a standard phantom, and human experiments were performed on the gastrocnemius and biceps brachii. Experimental results of phantom revealed DDSWI exhibited a high precision of <0.81 % and a low bias of <3.88 % in SWV measurements. The distribution of anisotropic properties in muscle was visualized with the anisotropic ratios of 1.54 and 2.27 for the gastrocnemius and biceps brachii, respectively. CONCLUSION The results highlight the potential of this novel anisotropic imaging in clinical applications because the conditions of musculoskeletal fiber orientation can be easily and accurately evaluated in real time by DDSWI.
Collapse
|