1
|
Gu B, Adeli H. Toward automated prediction of sudden unexpected death in epilepsy. Rev Neurosci 2022; 33:877-887. [PMID: 35619127 DOI: 10.1515/revneuro-2022-0024] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 04/19/2022] [Indexed: 12/14/2022]
Abstract
Sudden unexpected death in epilepsy (SUDEP) is a devastating yet overlooked complication of epilepsy. The rare and complex nature of SUDEP makes it challenging to study. No prediction or prevention of SUDEP is currently available in a clinical setting. In the past decade, significant advances have been made in our knowledge of the pathophysiologic cascades that lead to SUDEP. In particular, studies of brain, heart, and respiratory functions in both human patients at the epilepsy monitoring unit and animal models during fatal seizures provide critical information to integrate computational tools for SUDEP prediction. The rapid advances in automated seizure detection and prediction algorithms provide a fundamental framework for their adaption in predicting SUDEP. If a SUDEP can be predicted, then there will be a potential for medical intervention to be administered, either by their caregivers or via an implanted device automatically delivering electrical stimulation or medication, and finally save lives from fatal seizures. This article presents recent developments of SUDEP studies focusing on the pathophysiologic basis of SUDEP and computational implications of machine learning techniques that can be adapted and extended for SUDEP prediction. This article also discusses some novel ideas for SUDEP prediction and rescue including principal component analysis and closed-loop intervention.
Collapse
Affiliation(s)
- Bin Gu
- Department of Neuroscience, Ohio State University, Columbus, OH 43210, USA
| | - Hojjat Adeli
- Department of Neuroscience, Ohio State University, Columbus, OH 43210, USA.,Department of Biomedical Informatics, Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
2
|
Böttcher S, Vieluf S, Bruno E, Joseph B, Epitashvili N, Biondi A, Zabler N, Glasstetter M, Dümpelmann M, Van Laerhoven K, Nasseri M, Brinkman BH, Richardson MP, Schulze-Bonhage A, Loddenkemper T. Data quality evaluation in wearable monitoring. Sci Rep 2022; 12:21412. [PMID: 36496546 PMCID: PMC9741649 DOI: 10.1038/s41598-022-25949-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 11/25/2022] [Indexed: 12/13/2022] Open
Abstract
Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.
Collapse
Affiliation(s)
- Sebastian Böttcher
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany ,grid.5836.80000 0001 2242 8751Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Solveig Vieluf
- grid.38142.3c000000041936754XDivision of Epilepsy and Clinical Neurophysiology, Boston Children’s Hospital, Harvard Medical School, Boston, MS USA
| | - Elisa Bruno
- grid.13097.3c0000 0001 2322 6764Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology and Neuroscience, King’s College, London, UK
| | - Boney Joseph
- grid.66875.3a0000 0004 0459 167XBioelectronics Neurophysiology and Engineering Laboratory, Department of Neurology, Mayo Clinic, Rochester, MN USA
| | - Nino Epitashvili
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany
| | - Andrea Biondi
- grid.13097.3c0000 0001 2322 6764Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology and Neuroscience, King’s College, London, UK
| | - Nicolas Zabler
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany
| | - Martin Glasstetter
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany
| | - Matthias Dümpelmann
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany ,grid.5963.9Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
| | - Kristof Van Laerhoven
- grid.5836.80000 0001 2242 8751Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Mona Nasseri
- grid.66875.3a0000 0004 0459 167XBioelectronics Neurophysiology and Engineering Laboratory, Department of Neurology, Mayo Clinic, Rochester, MN USA ,grid.266865.90000 0001 2109 4358School of Engineering, University of North Florida, Jacksonville, FL USA
| | - Benjamin H. Brinkman
- grid.66875.3a0000 0004 0459 167XBioelectronics Neurophysiology and Engineering Laboratory, Department of Neurology, Mayo Clinic, Rochester, MN USA
| | - Mark P. Richardson
- grid.13097.3c0000 0001 2322 6764Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology and Neuroscience, King’s College, London, UK
| | - Andreas Schulze-Bonhage
- grid.7708.80000 0000 9428 7911Department of Neurosurgery, Epilepsy Center, Medical Center – University of Freiburg, Freiburg, Germany
| | - Tobias Loddenkemper
- grid.38142.3c000000041936754XDivision of Epilepsy and Clinical Neurophysiology, Boston Children’s Hospital, Harvard Medical School, Boston, MS USA
| |
Collapse
|
3
|
Intra- and Inter-Subject Perspectives on the Detection of Focal Onset Motor Seizures in Epilepsy Patients. SENSORS 2022; 22:s22093318. [PMID: 35591007 PMCID: PMC9105312 DOI: 10.3390/s22093318] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/19/2022] [Accepted: 04/22/2022] [Indexed: 01/15/2023]
Abstract
Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.
Collapse
|
4
|
Nielsen JM, Rades D, Kjaer TW. Wearable electroencephalography for ultra-long-term seizure monitoring: a systematic review and future prospects. Expert Rev Med Devices 2021; 18:57-67. [PMID: 34836477 DOI: 10.1080/17434440.2021.2012152] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION : Wearable electroencephalography (EEG) for objective seizure counting might transform the clinical management of epilepsy. Non-EEG modalities have been validated for the detection of convulsive seizures, but there is still an unmet need for the detection of non-convulsive seizures. AREAS COVERED : The main objective of this systematic review was to explore the current status on wearable surface- and subcutaneous EEG for long-term seizure monitoring in epilepsy. We included 17 studies and evaluated the progress on the field, including device specifications, intended populations, and main results on the published studies including diagnostic accuracy measures. Furthermore, we examine the hurdles for widespread clinical implementation. This systematic review and expert opinion both consults the PRISMA guidelines and reflects on the future perspectives of this emerging field. EXPERT OPINION : Wearable EEG for long-term seizure monitoring is an emerging field, with plenty of proposed devices and proof-of-concept clinical validation studies. The possible implications of these devices are immense including objective seizure counting and possibly forecasting. However, the true clinical value of the devices, including effects on patient important outcomes and clinical decision making is yet to be unveiled and large-scale clinical validation trials are called for.
Collapse
Affiliation(s)
- Jonas Munch Nielsen
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| | - Dirk Rades
- Department of Radiation Oncology, University of Lübeck, Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Troels Wesenberg Kjaer
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| |
Collapse
|
5
|
Böttcher S, Bruno E, Manyakov NV, Epitashvili N, Claes K, Glasstetter M, Thorpe S, Lees S, Dümpelmann M, Van Laerhoven K, Richardson MP, Schulze-Bonhage A. Detecting Tonic-Clonic Seizures in Multimodal Biosignal Data From Wearables: Methodology Design and Validation. JMIR Mhealth Uhealth 2021; 9:e27674. [PMID: 34806993 PMCID: PMC8663471 DOI: 10.2196/27674] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 07/23/2021] [Accepted: 09/03/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Video electroencephalography recordings, routinely used in epilepsy monitoring units, are the gold standard for monitoring epileptic seizures. However, monitoring is also needed in the day-to-day lives of people with epilepsy, where video electroencephalography is not feasible. Wearables could fill this gap by providing patients with an accurate log of their seizures. OBJECTIVE Although there are already systems available that provide promising results for the detection of tonic-clonic seizures (TCSs), research in this area is often limited to detection from 1 biosignal modality or only during the night when the patient is in bed. The aim of this study is to provide evidence that supervised machine learning can detect TCSs from multimodal data in a new data set during daytime and nighttime. METHODS An extensive data set of biosignals from a multimodal watch worn by people with epilepsy was recorded during their stay in the epilepsy monitoring unit at 2 European clinical sites. From a larger data set of 243 enrolled participants, those who had data recorded during TCSs were selected, amounting to 10 participants with 21 TCSs. Accelerometry and electrodermal activity recorded by the wearable device were used for analysis, and seizure manifestation was annotated in detail by clinical experts. Ten accelerometry and 3 electrodermal activity features were calculated for sliding windows of variable size across the data. A gradient tree boosting algorithm was used for seizure detection, and the optimal parameter combination was determined in a leave-one-participant-out cross-validation on a training set of 10 seizures from 8 participants. The model was then evaluated on an out-of-sample test set of 11 seizures from the remaining 2 participants. To assess specificity, we additionally analyzed data from up to 29 participants without TCSs during the model evaluation. RESULTS In the leave-one-participant-out cross-validation, the model optimized for sensitivity could detect all 10 seizures with a false alarm rate of 0.46 per day in 17.3 days of data. In a test set of 11 out-of-sample TCSs, amounting to 8.3 days of data, the model could detect 10 seizures and produced no false positives. Increasing the test set to include data from 28 more participants without additional TCSs resulted in a false alarm rate of 0.19 per day in 78 days of wearable data. CONCLUSIONS We show that a gradient tree boosting machine can robustly detect TCSs from multimodal wearable data in an original data set and that even with very limited training data, supervised machine learning can achieve a high sensitivity and low false-positive rate. This methodology may offer a promising way to approach wearable-based nonconvulsive seizure detection.
Collapse
Affiliation(s)
- Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany.,Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Elisa Bruno
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Nikolay V Manyakov
- Data Science Analytics & Insights, Janssen Research & Development, Beerse, Belgium
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | | | - Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | - Sarah Thorpe
- The RADAR-CNS Patient Advisory Board, King's College London, London, United Kingdom
| | - Simon Lees
- The RADAR-CNS Patient Advisory Board, King's College London, London, United Kingdom
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | - Kristof Van Laerhoven
- Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Mark P Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom.,National Institute of Health Research Biomedical Research Centre, South London and Maudsley NHS Foundation Trust, London, United Kingdom
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | -
- see Acknowledgements, London, United Kingdom
| |
Collapse
|
6
|
Glasstetter M, Böttcher S, Zabler N, Epitashvili N, Dümpelmann M, Richardson MP, Schulze-Bonhage A. Identification of Ictal Tachycardia in Focal Motor- and Non-Motor Seizures by Means of a Wearable PPG Sensor. SENSORS (BASEL, SWITZERLAND) 2021; 21:6017. [PMID: 34577222 PMCID: PMC8470979 DOI: 10.3390/s21186017] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/31/2021] [Accepted: 09/01/2021] [Indexed: 11/16/2022]
Abstract
Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.
Collapse
Affiliation(s)
- Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Nicolas Zabler
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Mark P. Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience King’s College London, London SE5 9RT, UK;
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| |
Collapse
|
7
|
Bruno E, Böttcher S, Viana PF, Amengual-Gual M, Joseph B, Epitashvili N, Dümpelmann M, Glasstetter M, Biondi A, Van Laerhoven K, Loddenkemper T, Richardson MP, Schulze-Bonhage A, Brinkmann BH. Wearable devices for seizure detection: Practical experiences and recommendations from the Wearables for Epilepsy And Research (WEAR) International Study Group. Epilepsia 2021; 62:2307-2321. [PMID: 34420211 DOI: 10.1111/epi.17044] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 07/20/2021] [Accepted: 08/05/2021] [Indexed: 02/06/2023]
Abstract
The Wearables for Epilepsy And Research (WEAR) International Study Group identified a set of methodology standards to guide research on wearable devices for seizure detection. We formed an international consortium of experts from clinical research, engineering, computer science, and data analytics at the beginning of 2020. The study protocols and practical experience acquired during the development of wearable research studies were discussed and analyzed during bi-weekly virtual meetings to highlight commonalities, strengths, and weaknesses, and to formulate recommendations. Seven major essential components of the experimental design were identified, and recommendations were formulated about: (1) description of study aims, (2) policies and agreements, (3) study population, (4) data collection and technical infrastructure, (5) devices, (6) reporting results, and (7) data sharing. Introducing a framework of methodology standards promotes optimal, accurate, and consistent data collection. It also guarantees that studies are generalizable and comparable, and that results can be replicated, validated, and shared.
Collapse
Affiliation(s)
- Elisa Bruno
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany.,Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Pedro F Viana
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK.,Faculty of Medicine, University of Lisbon, Lisboa, Portugal
| | - Marta Amengual-Gual
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Boney Joseph
- Department of Neurology and Biomedical Engineering, Mayo Foundation, Rochester, Minnesota, USA
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Andrea Biondi
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Kristof Van Laerhoven
- Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Tobias Loddenkemper
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Mark P Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg, Germany
| | - Benjamin H Brinkmann
- Department of Neurology and Biomedical Engineering, Mayo Foundation, Rochester, Minnesota, USA
| |
Collapse
|
8
|
Origin of post-ictal and post-anesthesia adverse effects and possibly of SUDEP. Med Hypotheses 2021; 151:110591. [PMID: 33873149 DOI: 10.1016/j.mehy.2021.110591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 03/10/2021] [Accepted: 04/05/2021] [Indexed: 11/20/2022]
Abstract
The origin of post-ictal malfunctions is debatable. We want to propose a novel idea of a cause of these adverse results occurring following epileptic seizures and anesthesia. Previously we have put forward the idea that epileptic seizures termination is caused by the function of the glymphatic system in the brain. A new measurement shows that this system can be much faster than what was estimated before. Moreover, the method enabling this speeding was actually measured in brains of epilepsy subjects. So, the main objection to our model is relegated. As a possible consequence of the glymphatic process, there can be an excess cleaning of the brain's interstitial fluid. We discuss possible adverse results of this process. This over-cleaning (that can, to a lower extent, occur also during anesthesia) which results post-ictally from the previous overexpression of fluid materials by the neurons during their seizure operation, can reduce ingredients essential for regular neuronal functioning, thereby leading to function reduction and EEG suppression which last until those materials are replenished. We argue that this ingredients' scarcity is the cause of post-ictal generalized EEG suppression (PGES), of post-ictal immobility (PI) and possibly of Sudden Unexpected Death in Epilepsy Patients (SUDEP). Similarly, such cleaning can lead to morbidity and even mortality problems following anesthesia. If our assumption is correct, this understanding of the process of the problems' origin can lead to a method to remedy them by judicial supplement of the lost materials.
Collapse
|
9
|
Abstract
Machine Learning From Wristband Sensor Data for Wearable, Noninvasive Seizure Forecasting Meisel C, El Atrache R, Jackson M, Schubach S, Ufongene C, Loddenkemper T. Epilepsia. 2020;61(12):2653-2666. doi:10.1111/epi.16719 Objective: Seizure forecasting may provide patients with timely warnings to adapt their daily activities and help clinicians deliver more objective, personalized treatments. Although recent work has convincingly demonstrated that seizure risk assessment is in principle possible, these early approaches relied largely on complex, often invasive setups including intracranial electrocorticography, implanted devices, and multichannel electroencephalography and required patient-specific adaptation or learning to perform optimally, all of which limit translation to broad clinical application. To facilitate broader adaptation of seizure forecasting in clinical practice, noninvasive, easily applicable techniques that reliably assess seizure risk without much prior tuning are crucial. Wristbands that continuously record physiological parameters, including electrodermal activity, body temperature, blood volume pulse, and actigraphy, may afford monitoring of autonomous nervous system function and movement relevant for such a task, hence minimizing potential complications associated with invasive monitoring and avoiding stigma associated with bulky external monitoring devices on the head. Methods: Here, we applied deep learning on multimodal wristband sensor data from 69 patients with epilepsy (total duration >2311 hours, 452 seizures) to assess its capability to forecast seizures in a statistically significant way. Results: Using a leave-one-subject-out cross-validation approach, we identified better-than-chance predictability in 43% of the patients. Time-matched seizure surrogate data analyses indicated forecasting not to be driven simply by time of day or vigilance state. Prediction performance peaked when all sensor modalities were used and did not differ between generalized and focal seizure types but generally increased with the size of the training data set, indicating potential further improvement with larger data sets in the future. Significance: Collectively, these results show that statistically significant seizure risk assessments are feasible from easy-to-use, noninvasive wearable devices without the need of patient-specific training or parameter optimization.
Collapse
|