1
|
Jarma D, Maestre JP, Sanchez J, Brodfuehrer S, Katz LE, Horner S, Kinney KA. Participant-collected household dust for assessing microorganisms and semi-volatile organic compounds in urban homes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168230. [PMID: 37951260 DOI: 10.1016/j.scitotenv.2023.168230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 10/17/2023] [Accepted: 10/28/2023] [Indexed: 11/13/2023]
Abstract
Dust samples collected by researchers and study participants from 43 U.S. urban homes were analyzed and compared to evaluate the feasibility of using participant-collected samples to assess indoor environmental exposures. The microbial and chemical composition of participant-collected (and shipped) samples were compared to researcher-collected samples from the same household, using dust recovered from each home's heating, ventilation, and air conditioning (HVAC) filter. The bacterial and fungal communities present in all dust samples were determined via MiSeq 16S and ITS sequencing, and the concentrations of 27 semi-volatile organic compounds (7 orthophosphates, 6 phthalates, and 14 brominated flame retardants) were determined via GC-MS. Self-report data on the home environment was collected via an online survey of study participants. While the researcher-collected samples (RCS) yielded greater mass than the participant-collected samples (PCS), the alpha and beta diversities of the bacterial and fungal communities recovered in the RCS and PCS were not significantly different, indicating that PCS is a viable option for indoor microbiome studies of residential homes. The microbial communities recovered in both cases reflected the dominance of human-associated bacterial taxa and outdoor-associated fungal taxa with similar pathogen-associated taxa present in each sample type. In both PCS and RCS, the amount of carpet in the home and the frequency of bleach use had a significant effect on the composition of fungal communities. Semi-volatile organic compounds (SVOCs) of potential human health concern, were commonly detected in the homes. Organophosphates and phthalates were recovered at a similar frequency in both PCS and RCS. Measured SVOC concentration levels were consistent with previous indoor studies although differences were observed between PCS and RCS for several SVOCs. This study demonstrates the potential and challenges associated with participant-collected dust samples for indoor environment studies.
Collapse
Affiliation(s)
- D Jarma
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin, TX, USA
| | - J P Maestre
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin, TX, USA
| | - J Sanchez
- School of Social Work, The University of Texas at Austin, TX, USA
| | - S Brodfuehrer
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin, TX, USA
| | - L E Katz
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin, TX, USA
| | - S Horner
- School of Nursing, The University of Texas at Austin, TX, USA
| | - K A Kinney
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin, TX, USA.
| |
Collapse
|
2
|
Li Z, Zheng N, An Q, Li X, Sun S, Zhang W, Ji Y, Wang S, Li P. Impact of environmental factors and bacterial interactions on dust mite allergens in different indoor dust. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:157177. [PMID: 35803427 DOI: 10.1016/j.scitotenv.2022.157177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 06/11/2022] [Accepted: 07/01/2022] [Indexed: 06/15/2023]
Abstract
Indoor dust is the main carrier of indoor pollutants, especially dust mite allergens and bacteria, they can trigger asthma, rhinitis, eczema and other allergic diseases. However, the interactions between dust mite allergens and bacterial communities in different types of indoor dust are not clear. The study focused on particulate and flocculent fibrous dust, explored the concentrations of Der p 1 (Dermatophagoides pteronyssinus) and Der f 1 (D. farinae) in 46 households in Changchun and their environmental influences, characterized the bacterial communities by high-throughput sequencing, and the interactions between Der p 1, Der f 1 and bacterial communities were explored. The results showed that Der p 1 and Der f 1 tended to accumulate more in flocculent fibrous dust, and Der p 1 predominated in the indoor dust samples. The floor height, years of housing occupancy and the living areas all affected the concentrations of dust mite allergens. In bacterial community, Proteobacteria, Firmicutes and Actinobacteria were leading phyla in the two types of dust. Kocuria, Blastococcus and Massilia were dominating genera in particulate dust and Acinetobacter, Lactobacillus, Corynebacterium_1 were dominating genera in flocculent fibrous dust. The overall diversity and species richness of bacteria in particulate dust were significantly higher than those in flocculent dust (p < 0.001). The living area was an important environmental factor affecting the bacterial community in flocculent fibrous dust (p < 0.01). The interaction between the relative abundance of Proteobacteria, Firmicutes and Actinobacteria and dust mite allergen concentrations significantly differed between the two dust types, indicating that bacteria could be used both as food and to establish symbiotic relationships with household dust mites (HDMs) hosts and provide nutrition.
Collapse
Affiliation(s)
- Zimeng Li
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Na Zheng
- College of New Energy and Environment, Jilin University, Changchun, 130012, China; Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun, 130012, China.
| | - Qirui An
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Xiaoqian Li
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Siyu Sun
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Wenhui Zhang
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Yining Ji
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Sujing Wang
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| | - Pengyang Li
- College of New Energy and Environment, Jilin University, Changchun, 130012, China
| |
Collapse
|
3
|
Moghtaderi M, Ashraf MA, Teshnizi SH, Nabavizadeh H, Farjadian S, Fereidouni M. The level of allergens in dust samples collected from selected schools in Shiraz, Iran and its asthma-risk implications. Allergol Immunopathol (Madr) 2020; 48:90-94. [PMID: 31477397 DOI: 10.1016/j.aller.2019.05.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/05/2019] [Accepted: 05/10/2019] [Indexed: 01/21/2023]
Abstract
BACKGROUND Both home and school are important places where children are exposed to various indoor allergens. This study aimed to identify the profile of indoor allergens in schools and its impact on asthma development. METHODS A total of 104 classrooms from 52 schools were selected for dust collection during the fall of 2017. The levels of indoor allergens including dust mite (Der f1, Der p1), cat (Fel d1), cockroach (Bla g1) and mouse (Mus m1) were measured by enzyme linked immunosorbent assay (ELISA). The diagnosis of asthma was made in all students of the selected classes by the allergist. The collected data were analyzed using SPSS version 21.0. RESULTS Out of 2816 students in the selected classes, 180 students were involved with asthma. Students were mostly exposed to Bla g1 (83.1%), followed by Der f1 (51.5%), Mus m 1 (45.5%), Der p1 (8.9%) and Fel d1 (7.9%) in the dust collected from 101 classrooms. Although levels of all studied allergens in the settled dust of the classrooms were low, there was a relationship between Fel d1 in the classroom dust and development of asthma. CONCLUSION This study showed considerable levels of cockroach allergens in schools. Exposure to cat allergen in our schools played an important role in asthma development; further school-based investigations require evaluating the role of classroom allergen on asthma development.
Collapse
Affiliation(s)
- M Moghtaderi
- Allergy Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - M A Ashraf
- Allergy Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - S H Teshnizi
- Clinical Research Development Center of Children Hospital, Hormozgan University of Medical Sciences, Iran
| | - H Nabavizadeh
- Allergy Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - S Farjadian
- Allergy Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - M Fereidouni
- Allergy and Immunology Research Center, Birjand University of Medical Sciences, Birjand, Iran
| |
Collapse
|
4
|
Haines SR, Adams RI, Boor BE, Bruton TA, Downey J, Ferro AR, Gall E, Green BJ, Hegarty B, Horner E, Jacobs DE, Lemieux P, Misztal PK, Morrison G, Perzanowski M, Reponen T, Rush RE, Virgo T, Alkhayri C, Bope A, Cochran S, Cox J, Donohue A, May AA, Nastasi N, Nishioka M, Renninger N, Tian Y, Uebel-Niemeier C, Wilkinson D, Wu T, Zambrana J, Dannemiller KC. Ten questions concerning the implications of carpet on indoor chemistry and microbiology. BUILDING AND ENVIRONMENT 2019; 170:1-16. [PMID: 32055099 PMCID: PMC7017391 DOI: 10.1016/j.buildenv.2019.106589] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Carpet and rugs currently represent about half of the United States flooring market and offer many benefits as a flooring type. How carpets influence our exposure to both microorganisms and chemicals in indoor environments has important health implications but is not well understood. The goal of this manuscript is to consolidate what is known about how carpet impacts indoor chemistry and microbiology, as well as to identify the important research gaps that remain. After describing the current use of carpet indoors, questions focus on five specific areas: 1) indoor chemistry, 2) indoor microbiology, 3) resuspension and exposure, 4) current practices and future needs, and 5) sustainability. Overall, it is clear that carpet can influence our exposures to particles and volatile compounds in the indoor environment by acting as a direct source, as a reservoir of environmental contaminants, and as a surface supporting chemical and biological transformations. However, the health implications of these processes are not well known, nor how cleaning practices could be optimized to minimize potential negative impacts. Current standards and recommendations focus largely on carpets as a primary source of chemicals and on limiting moisture that would support microbial growth. Future research should consider enhancing knowledge related to the impact of carpet in the indoor environment and how we might improve the design and maintenance of this common material to reduce our exposure to harmful contaminants while retaining the benefits to consumers.
Collapse
Affiliation(s)
- Sarah R. Haines
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, Environmental Health Sciences, College of Public Health, and Environmental Sciences Graduate Program, The Ohio State University, Columbus, OH, 43210, USA
| | - Rachel I. Adams
- Plant & Microbial Biology, University of California, Berkeley, CA, 94720, USA
| | - Brandon E. Boor
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | | | - John Downey
- Cleaning Industry Research Institute, Granville, OH, 43023, USA
| | - Andrea R. Ferro
- Department of Civil and Environmental Engineering, Clarkson University, Potsdam, NY, 13699, USA
| | - Elliott Gall
- Department of Mechanical and Materials Engineering, Portland State University, Portland, OR, 97201, USA
| | - Brett J. Green
- Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, 26505, USA
| | - Bridget Hegarty
- Civil and Environmental Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Elliott Horner
- UL Environment and Sustainability, Marietta, GA, 30067, USA
| | - David E. Jacobs
- National Center for Healthy Housing, Columbia, MD, 21044, USA
| | - Paul Lemieux
- Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC, 27711, USA
| | - Pawel K. Misztal
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, TX, 78712, USA
| | - Glenn Morrison
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC, 27599, USA
| | - Matthew Perzanowski
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, 10032, USA
| | - Tiina Reponen
- Division of Environmental and Industrial Hygiene, Department of Environmental Health, College of Medicine, University of Cincinnati, Cincinnati, OH, 45220, USA
| | - Rachael E. Rush
- Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, 26505, USA
- Department of Microbiology, Immunology, and Cell Biology, West Virginia University, Morgantown, WV, 26506, USA
| | - Troy Virgo
- Shaw Industries, Inc., Dalton, GA, 30722-2128, USA
| | - Celine Alkhayri
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Ashleigh Bope
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, Environmental Health Sciences, College of Public Health, and Environmental Sciences Graduate Program, The Ohio State University, Columbus, OH, 43210, USA
| | - Samuel Cochran
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, Environmental Health Sciences, College of Public Health, and Environmental Sciences Graduate Program, The Ohio State University, Columbus, OH, 43210, USA
| | - Jennie Cox
- Division of Environmental and Industrial Hygiene, Department of Environmental Health, College of Medicine, University of Cincinnati, Cincinnati, OH, 45220, USA
| | - Allie Donohue
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Andrew A. May
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Nicholas Nastasi
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, Environmental Health Sciences, College of Public Health, and Environmental Sciences Graduate Program, The Ohio State University, Columbus, OH, 43210, USA
| | - Marcia Nishioka
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Nicole Renninger
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Yilin Tian
- Department of Environmental Science, Policy, and Management, University of California, Berkeley, CA, 94720, USA
| | - Christina Uebel-Niemeier
- Division of Environmental and Industrial Hygiene, Department of Environmental Health, College of Medicine, University of Cincinnati, Cincinnati, OH, 45220, USA
| | | | - Tianren Wu
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Jordan Zambrana
- Indoor Environments Division, Office of Air and Radiation, U.S. Environmental Protection Agency, Washington, DC, 20460, USA
| | - Karen C. Dannemiller
- Department of Civil, Environmental & Geodetic Engineering, College of Engineering, and Environmental Health Sciences, College of Public Health, The Ohio State University, Columbus, OH, 43210, USA
| |
Collapse
|
5
|
Household Dust: Loadings and PM10-Bound Plasticizers and Polycyclic Aromatic Hydrocarbons. ATMOSPHERE 2019. [DOI: 10.3390/atmos10120785] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Residential dust is recognized as a major source of environmental contaminants, including polycyclic aromatic hydrocarbons (PAHs) and plasticizers, such as phthalic acid esters (PAEs). A sampling campaign was carried out to characterize the dust fraction of particulate matter with an aerodynamic diameter smaller than 10 µm (PM10), using an in situ resuspension chamber in three rooms (kitchen, living room, and bedroom) of four Spanish houses. Two samples per room were collected with, at least, a one-week interval. The PM10 samples were analyzed for their carbonaceous content by a thermo-optical technique and, after solvent extraction, for 20 PAHs, 8 PAEs and one non-phthalate plasticizer (DEHA) by gas chromatography-mass spectrometry. In general, higher dust loads were observed for parquet flooring as compared with tile. The highest dust loads were obtained for rugs. Total carbon accounted for 9.3 to 51 wt% of the PM10 mass. Plasticizer mass fractions varied from 5 µg g−1 to 17 mg g−1 PM10, whereas lower contributions were registered for PAHs (0.98 to 116 µg g−1). The plasticizer and PAH daily intakes for children and adults via dust ingestion were estimated to be three to four orders of magnitude higher than those via inhalation and dermal contact. The thoracic fraction of household dust was estimated to contribute to an excess of 7.2 to 14 per million people new cancer cases, which exceeds the acceptable risk of one per million.
Collapse
|
6
|
Liang Y, Bi C, Wang X, Xu Y. A general mechanistic model for predicting the fate and transport of phthalates in indoor environments. INDOOR AIR 2019; 29:55-69. [PMID: 30339320 DOI: 10.1111/ina.12514] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 09/07/2018] [Accepted: 10/12/2018] [Indexed: 06/08/2023]
Abstract
A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model-predicted evolving concentrations of benzyl butyl phthalate in indoor air and settled dust and on interior surfaces are in good agreement with measurements. Sensitivity analysis was performed to quantify the effects of parameter uncertainties on model predictions. The model was then applied to a typical residential environment to investigate the fate of di-2-ethylhexyl phthalate (DEHP) and the factors that affect its transport. The predicted steady-state DEHP concentrations were 0.14 μg/m3 in indoor air and ranged from 80 to 46 000 μg/g in settled dust on various surfaces, which are generally consistent with the measurements of previous studies in homes in different countries. An increase in the mass concentration of indoor particles may significantly enhance DEHP emission and its concentrations in air and on surfaces, whereas increasing ventilation has only a limited effect in reducing DEHP in indoor air. The influence of cleaning activities on reducing DEHP concentration in indoor air and on interior surfaces was quantified, and the results showed that DEHP exposure can be reduced by frequent and effective cleaning activities and the removal of existing sources, though it may take a relatively long period of time for the levels to drop significantly. Finally, the model was adjusted to identify the relative contributions of gaseous sorption and particulate-bound deposition to the overall uptake of semi-volatile organic compounds (SVOCs) by indoor surfaces as functions of time and the octanol-air partition coefficient (Koa ) of the chemical. Overall, the model clarifies the mechanisms that govern the emission of phthalates and the subsequent interactions among air, suspended particles, settled dust, and interior surfaces. This model can be easily extended to incorporate additional indoor source materials/products, sorption surfaces, particle sources, and room spaces. It can also be modified to predict the fate and transport of other SVOCs, such as phthalate-alternative plasticizers, flame retardants, and biocides, and serves to improve our understanding of human exposure to SVOCs in indoor environments.
Collapse
Affiliation(s)
- Yirui Liang
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas
| | - Chenyang Bi
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas
| | - Xinke Wang
- Department of Civil Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Ying Xu
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas
- Department of Building Science, Tsinghua University, Beijing, China
| |
Collapse
|
7
|
The importance of specific IgE antibodies in epidemiology of allergic rhinitis and asthma - the Epidemiology of Allergic Diseases in Poland (ECAP) survey: part one. Influence of allergy risk factors on concentration of specific IgE antibodies in serum. Postepy Dermatol Alergol 2018; 35:520-526. [PMID: 30429713 PMCID: PMC6232542 DOI: 10.5114/pdia.2017.70894] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 09/14/2017] [Indexed: 11/17/2022] Open
Abstract
Introduction Specific immunoglobulins E (sIgE) are important parameters to estimate severity of allergic diseases. Aim To determine the influence of allergy risk factors on the concentration of specific IgE antibodies in serum. Material and methods The concentration of sIgE antibodies against allergens Dermatophagoides pteronyssinus, cat dander, timothy grass, Alternaria alternata were determined in serum of 4077 respondents randomly selected from 9 regions (ECAP study). The positive results of sIgE (≥ 0.35 IU/ml) were correlated to answers in questionnaires ECRHSII and ISAAC. Results sIgE are more frequently detected in respondents declaring an allergic disease of a father than of a mother (D. pteronyssinus p < 0.05, A. alternata p < 0.01). An early beginning to attend school, kindergarten or nursery increases the frequency of sIgE detection (p < 0.05). If the number of children who slept in the same room as a respondent before the respondent was five years old, was lower, sIgE antibodies are more frequently detected (p < 0.05). Relating to: 1) all 4 allergens, sIgE are the most frequently detected in respondents declaring absence of a carpet/rug at home (p < 0.05), 2) cat dander – less frequently detected in respondents who have a cat at home at the age of 1–4 years (p < 0.005). Conclusions Carpets/rugs capture a portion of mite, epidermal, mould allergens located at home, wherefore absence of a carpet or rug causes greater stimulation of an immune system by these allergens; as a consequence, IgE antibodies are the most frequently detected in respondents. Household contacts of the respondents, at the age of 1–4 years, with cats induced partial immune tolerance to cat dander.
Collapse
|
8
|
Kwan S, Shaughnessy R, Hegarty B, Haverinen‐Shaughnessy U, Peccia J. The reestablishment of microbial communities after surface cleaning in schools. J Appl Microbiol 2018; 125:897-906. [DOI: 10.1111/jam.13898] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 04/13/2018] [Accepted: 04/21/2018] [Indexed: 12/24/2022]
Affiliation(s)
- S.E. Kwan
- Department of Chemical and Environmental Engineering Yale University New Haven CT 06520‐8286 USA
| | - R.J. Shaughnessy
- Department of Chemical Engineering Indoor Air Program The University of Tulsa Tulsa OK 74101‐9700 USA
| | - B. Hegarty
- Department of Chemical and Environmental Engineering Yale University New Haven CT 06520‐8286 USA
| | - U. Haverinen‐Shaughnessy
- Department of Chemical Engineering Indoor Air Program The University of Tulsa Tulsa OK 74101‐9700 USA
| | - J. Peccia
- Department of Chemical and Environmental Engineering Yale University New Haven CT 06520‐8286 USA
| |
Collapse
|
9
|
Do Carpets Impair Indoor Air Quality and Cause Adverse Health Outcomes: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15020184. [PMID: 29360764 PMCID: PMC5858259 DOI: 10.3390/ijerph15020184] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 12/21/2017] [Accepted: 01/19/2018] [Indexed: 12/22/2022]
Abstract
Several earlier studies have shown the presence of more dust and allergens in carpets compared with non-carpeted floors. At the same time, adverse effects of carpeted floors on perceived indoor air quality as well as worsening of symptoms in individuals with asthma and allergies were reported. Avoiding extensive carpet use in offices, schools, kindergartens and bedrooms has therefore been recommended by several health authorities. More recently, carpet producers have argued that former assessments were obsolete and that modern rugs are unproblematic, even for those with asthma and allergies. To investigate whether the recommendation to be cautious with the use of carpets is still valid, or whether there are new data supporting that carpet flooring do not present a problem for indoor air quality and health, we have reviewed the literature on this matter. We have not found updated peer reviewed evidence that carpeted floor is unproblematic for the indoor environment. On the contrary, also more recent data support that carpets may act as a repository for pollutants which may become resuspended upon activity in the carpeted area. Also, the use of carpets is still linked to perception of reduced indoor air quality as well as adverse health effects as previously reported. To our knowledge, there are no publications that report on deposition of pollutants and adverse health outcomes associated with modern rugs. However, due to the three-dimensional structure of carpets, any carpet will to some extent act like a sink. Thus, continued caution should still be exercised when considering the use of wall-to-wall carpeted floors in schools, kindergartens and offices, as well as in children’s bedrooms unless special needs indicate that carpets are preferable.
Collapse
|
10
|
Permaul P, Phipatanakul W. School Environmental Intervention Programs. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY. IN PRACTICE 2018; 6:22-29. [PMID: 29310758 PMCID: PMC5773264 DOI: 10.1016/j.jaip.2017.10.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 09/29/2017] [Accepted: 10/03/2017] [Indexed: 12/30/2022]
Abstract
Exposure to indoor allergens and pollutants plays a significant part in the development of asthma and its associated morbidity. Inner-city children with asthma are disproportionately affected by these exposures with increased asthma morbidity. Although years of previous research have linked exposures in the urban home environment with significant childhood asthma disease, many of these allergens are also present in inner-city school environments. Therefore, evaluation of the school environment of patients with asthma is also essential. School-based environmental interventions may offer benefit for this problem and has the potential to help many children with asthma at once in a cost-effective manner. It is important that environmental health researchers continue to assess which interventions are most practical and result in the greatest measurable improvements.
Collapse
Affiliation(s)
- Perdita Permaul
- Division of Pediatric Allergy and Immunology, Massachusetts General Hospital for Children, Boston, Mass; Harvard Medical School, Boston, Mass
| | - Wanda Phipatanakul
- Harvard Medical School, Boston, Mass; Division of Allergy and Immunology, Boston Children's Hospital, Boston, Mass.
| |
Collapse
|
11
|
Recent advances in environmental controls outside the home setting. Curr Opin Allergy Clin Immunol 2016; 16:135-41. [PMID: 26859366 DOI: 10.1097/aci.0000000000000250] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE OF REVIEW It has been well studied that aeroallergen, mold, and airborne pollutant exposure in the inner-city home environment is associated with significant childhood asthma morbidity. Although the home environment has been extensively studied, the school environment is less well understood. RECENT FINDINGS In this article, we discuss the relationship between environmental exposures within the school and daycare environment and pediatric asthma morbidity and novel environmental interventions designed to help mitigate pediatric asthma morbidity. SUMMARY Studies assessing environmental exposures outside the home environment and interventions to mitigate these exposures have the potential to reduce pediatric asthma morbidity. Further study in this area should focus on the complex cost benefit analyses of environmental interventions outside the home setting, while controlling for the home environment.
Collapse
|
12
|
Niesler A, Ścigała G, Łudzeń-Izbińska B. Cat (Fel d 1) and dog (Can f 1) allergen levels in cars, dwellings and schools. AEROBIOLOGIA 2016; 32:571-580. [PMID: 27616812 PMCID: PMC4996870 DOI: 10.1007/s10453-016-9433-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 03/01/2016] [Indexed: 06/06/2023]
Abstract
Pets are an important source of indoor allergens. The aim of the study was to compare cat and dog allergen levels in cars, schools and homes. The study was carried out in 17 cars, 14 classrooms and 19 dwellings located in the highly industrialized and urbanized region of Poland. Dust and air samples were analyzed for Fel d 1 and Can f 1 using a double monoclonal ELISA assay. The highest amounts of cat and dog allergens (Fel d 1: 1169 μg/g; Can f 1: 277 μg/g) were found in dwellings with pets. Allergen concentrations were correlated with the number of animals kept at home. Although concentrations on automobile seats were lower, Fel d 1 levels exceeded 8 μg/g in 23.5 % of cars and high levels of Can f 1 (>10 μg/g) were found in 17.6 % of cars. The study revealed that cars of pet owners may be reservoirs of cat and dog allergens even when animals are not transported in them. In schools, concentrations of pet allergens did not reach high levels, but the moderate levels of Fel d 1 (≥1-8 μg/g) and Can f 1 (≥2-10 μg/g) were detected in 42.9 and 7.1 % of the investigated classrooms. Concentrations of cat and dog allergen in schools were higher than in homes without pets. While airborne Fel d 1 and Can f 1 levels were found low, residential allergen concentrations in settled dust and air were correlated. The study results suggest that classrooms and cars of pet owners may be important sites of exposure to cat and dog allergens, though the highest concentrations of Fel d 1 and Can f 1 are found in homes of pet owners.
Collapse
Affiliation(s)
- A. Niesler
- Department of Biohazards and Immunoallergology, Institute of Occupational Medicine and Environmental Health, 13 Kościelna Street, 41-200 Sosnowiec, Poland
| | - G. Ścigała
- Department of Biohazards and Immunoallergology, Institute of Occupational Medicine and Environmental Health, 13 Kościelna Street, 41-200 Sosnowiec, Poland
| | - B. Łudzeń-Izbińska
- Department of Biohazards and Immunoallergology, Institute of Occupational Medicine and Environmental Health, 13 Kościelna Street, 41-200 Sosnowiec, Poland
| |
Collapse
|
13
|
Hauptman M, Phipatanakul W. The school environment and asthma in childhood. Asthma Res Pract 2015; 1:12. [PMID: 26523228 PMCID: PMC4627718 DOI: 10.1186/s40733-015-0010-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Accepted: 09/18/2015] [Indexed: 01/25/2023] Open
Abstract
In this article, we discuss the relationship between environmental exposures within the school environment and pediatric asthma morbidity. This article will conclude by reviewing novel school based asthma education and therapeutic programs and environmental interventions designed to help mitigate pediatric asthma morbidity.
Collapse
Affiliation(s)
- Marissa Hauptman
- Division of General Pediatrics, Boston Children’s Hospital, Boston, MA USA
- Division of Allergy and Immunology, Boston Children’s Hospital, Boston, MA USA
- Harvard Medical School, Boston, MA USA
- Region 1 New England Pediatric Environmental Health Specialty Unit, Boston, MA USA
- Boston Children’s Hospital, 300 Longwood Ave., Boston, MA 02115 USA
| | - Wanda Phipatanakul
- Division of Allergy and Immunology, Boston Children’s Hospital, Boston, MA USA
- Harvard Medical School, Boston, MA USA
- Boston Children’s Hospital, 300 Longwood Ave., Boston, MA 02115 USA
| |
Collapse
|
14
|
Kielb C, Lin S, Muscatiello N, Hord W, Rogers-Harrington J, Healy J. Building-related health symptoms and classroom indoor air quality: a survey of school teachers in New York State. INDOOR AIR 2015; 25:371-380. [PMID: 25196499 DOI: 10.1111/ina.12154] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2014] [Accepted: 08/27/2014] [Indexed: 06/03/2023]
Abstract
UNLABELLED Most previous research on indoor environments and health has studied school children or occupants in non-school settings. This investigation assessed building-related health symptoms and classroom characteristics via telephone survey of New York State school teachers. Participants were asked about 14 building-related symptoms and 23 classroom characteristics potentially related to poor indoor air quality (IAQ). Poisson regression analysis was used to assess the relationship between these symptoms and each classroom characteristic, controlling for potential confounders. About 500 teachers completed the survey. The most frequently reported classroom characteristics included open shelving (70.7%), food eaten in class (65.5%), dust (59.1%), and carpeting (46.9%). The most commonly reported symptoms included sinus problems (16.8%), headache (15.0%), allergies/congestion (14.8%), and throat irritation (14.6%). Experiencing one or more symptoms was associated most strongly with reported dust (relative risk (RR) = 3.67; 95% confidence interval (CI): 2.62-5.13), dust reservoirs (RR = 2.13; 95% CI: 1.72-2.65), paint odors (RR = 1.73; 95% CI: 1.40-2.13), mold (RR = 1.71; 95% CI: 1.39-2.11), and moldy odors (RR = 1.65 95% CI: 1.30-2.10). Stronger associations were found with increasing numbers of reported IAQ-related classroom characteristics. Similar results were found with having any building-related allergic/respiratory symptom. This research adds to the body of evidence underscoring the importance to occupant health of school IAQ. PRACTICAL IMPLICATIONS Teachers play an important role in educating children, and teacher well-being is important to this role. Health symptoms among New York teachers while at work are common and appear to be associated with numerous characteristics related to poor classroom IAQ. Improving school Indoor Air Quality may reduce sickness and absenteeism and improve teacher performance.
Collapse
Affiliation(s)
- C Kielb
- NYS Department of Health, Center for Environmental Health, Albany, NY, USA
| | - S Lin
- NYS Department of Health, Center for Environmental Health, Albany, NY, USA
- University at Albany School of Public Health, Rensselaer, NY, USA
| | - N Muscatiello
- NYS Department of Health, Center for Environmental Health, Albany, NY, USA
| | - W Hord
- New York State United Teachers, Latham, NY, USA
| | | | - J Healy
- New York State United Teachers, Latham, NY, USA
| |
Collapse
|
15
|
Tian Y, Sul K, Qian J, Mondal S, Ferro AR. A comparative study of walking-induced dust resuspension using a consistent test mechanism. INDOOR AIR 2014; 24:592-603. [PMID: 24605758 DOI: 10.1111/ina.12107] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Accepted: 03/01/2014] [Indexed: 06/03/2023]
Abstract
UNLABELLED Human walking influences indoor air quality mainly by resuspending dust particles settled on the floor. This study characterized walking-induced particle resuspension as a function of flooring type, relative humidity (RH), surface dust loading, and particle size using a consistent resuspension mechanism. Five types of flooring, including hardwood, vinyl, high-density cut pile carpet, low-density cut pile carpet, and high-density loop carpet, were tested with two levels of RH (40% and 70%) and surface dust loading (2 and 8 g/m(2) ), respectively. Resuspension fraction ra (fraction of surface dust resuspended per step) for house dust was found to be varied from 10(-7) to 10(-4) (particle size: 0.4-10 µm). Results showed that for particles at 0.4-3.0 µm, the difference in resuspension fraction between carpets and hard floorings was not significant. For particles at 3.0-10.0 µm, carpets exhibited higher resuspension fractions compared with hard floorings. Increased RH level enhanced resuspension on high-density cut pile carpet, whereas the opposite effect was observed on hard floorings. Higher surface dust loading was associated with lower resuspension fractions on carpets, while on hard floorings the effect of surface dust loading varied with different RH levels. PRACTICAL IMPLICATIONS The results from this study validate the recommendation that people sensitive to allergens could select hard floorings to reduce exposure and related adverse health outcomes. The results can also be applied to exposure models to determine the overall impact of exposure to resuspension as compared with other particle sources.
Collapse
Affiliation(s)
- Y Tian
- Institute for a Sustainable Environment, Clarkson University, Potsdam, NY, USA
| | | | | | | | | |
Collapse
|
16
|
Chruszcz M, Mikolajczak K, Mank N, Majorek KA, Porebski PJ, Minor W. Serum albumins-unusual allergens. Biochim Biophys Acta Gen Subj 2013; 1830:5375-81. [PMID: 23811341 DOI: 10.1016/j.bbagen.2013.06.016] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Revised: 06/13/2013] [Accepted: 06/17/2013] [Indexed: 01/27/2023]
Abstract
BACKGROUND Albumins are multifunctional proteins present in the blood serum of animals. They can bind and transport a wide variety of ligands which they accommodate due to their conformational flexibility. Serum albumins are highly conserved both in amino acid sequence and three-dimensional structure. Several mammalian and avian serum albumins (SAs) are also allergens. Sensitization to one of the SAs coupled with the high degree of conservation between SAs may result in cross-reactive antibodies in allergic individuals. Sensitivity to SA generally begins with exposure to an aeroallergen, which can then lead to cross-sensitization to serum albumins present in food. SCOPE OF REVIEW This review focuses on the allergenicity of SAs presented in a structural context. MAJOR CONCLUSIONS SA allergenicity is unusual taking into account the high sequence identity and similarity between SA from different species and human serum albumin. Cross-reactivity of human antibodies towards different SAs is one of the most important characteristics of these allergens. GENERAL SIGNIFICANCE Establishing a relationship between sequence and structure of different SAs and their interactions with antibodies is crucial for understanding the mechanisms of cross-sensitization of atopic individuals. Structural information can also lead to better design and production of recombinant SAs to replace natural proteins in allergy testing and desensitization. Therefore, structural analyses are important for diagnostic and treatment purposes. This article is part of a Special Issue entitled Serum Albumin.
Collapse
Affiliation(s)
- Maksymilian Chruszcz
- Department of Chemistry and Biochemistry, University of South Carolina, 631 Sumter Street, Columbia, SC 29208, USA.
| | | | | | | | | | | |
Collapse
|
17
|
Abstract
Pyroglyphid mites are primarily associated with allergen exposure at home; hence the name house dust mites. However, we have found numerous studies reporting pyroglyhid mite levels in public and occupational settings. This review presents the findings of house dust mite allergens (family Pyroglyphidae, species Dermatophagoides) as potential work-related risk factors and proposes occupations at risk of house dust mite-related diseases. Pyroglyphid mites or their allergens are found in various workplaces, but clinically relevant exposures have been observed in hotels, cinemas, schools, day-care centres, libraries, public transportation (buses, trains, taxies, and airplanes), fishing-boats, submarines, poultry farms, and churches. Here we propose a classification of occupational risk as low (occasional exposure to mite allergen levels up to 2 μg g(-1)), moderate (exposure between 2 μg g(-1) and 10 μg g(-1)), and high (exposure >10 μg g(-1)). The classification of risk should include factors relevant for indoor mite population (climate, building characteristics, and cleaning schedule). To avoid development or aggravation of allergies associated with exposure to house dust mites at work, occupational physicians should assess exposure risk at work, propose proper protection, provide vocational guidance to persons at risk and conduct pre-employment and periodic examinations to diagnose new allergy cases. Protection at work should aim to control dust mite levels at work. Measures may include proper interior design and regular cleaning and building maintenance.
Collapse
|
18
|
Norbäck D, Wieslander G, Zhang X, Zhao Z. Respiratory symptoms, perceived air quality and physiological signs in elementary school pupils in relation to displacement and mixing ventilation system: an intervention study. INDOOR AIR 2011; 21:427-437. [PMID: 21443696 DOI: 10.1111/j.1600-0668.2011.00717.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
UNLABELLED Schools may be poorly ventilated and may contain furry pet allergens, particles and microorganisms. We studied health effects when changing from mixing ceiling ventilation to two types of displacement ventilation, front ventilation system (FVS) and floor master system (FMS). The study included pupils in three elementary school classes (N = 61), all with floor heating. One class received blinded interventions; the two others were unchanged (controls). Ventilation flow and supply air temperature was kept constant. The medical investigation included tear film stability (BUT), nasal patency and a questionnaire containing rating scales. When changing from mixing ventilation to FVS, the pupils (N = 26) perceived better air quality (P = 0.006) and less dyspnoea (P = 0.007) as compared to controls (N = 35), and BUT was improved (P = 0.03). At desk level, mean CO(2) was reduced from 867 to 655 ppm. Formaldehyde and viable bacteria were numerically lower, while total bacteria and molds were higher with displacement ventilation. There was no difference in symptoms or signs when changing from FVS to FMS. Cat (Der p1), dog (Can f1) and horse allergen (Equ cx) were common in air at all conditions. In conclusion, displacement ventilation may have certain positive health effects among pupils, as compared to conventional mixing ceiling systems. PRACTICAL IMPLICATIONS Displacement ventilation may be a suitable ventilation principle for achieving good indoor environment in classrooms. The type of supply air diffuser does not seem to be of major importance. The combination of floor heating and displacement ventilation can be a useful way of avoiding the previously described problem of thermal discomfort.
Collapse
Affiliation(s)
- D Norbäck
- Department of Medical Science, Uppsala University, Occupational and Environmental Medicine, University Hospital, SE, Sweden.
| | | | | | | |
Collapse
|
19
|
Williams AH, Smith JT, Hudgens EE, Rhoney S, Ozkaynak H, Hamilton RG, Gallagher JE. Allergens in household dust and serological indicators of atopy and sensitization in Detroit children with history-based evidence of asthma. J Asthma 2011; 48:674-84. [PMID: 21827376 DOI: 10.3109/02770903.2011.599909] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Home exposure to allergens is an important factor in the development of sensitization and subsequent exacerbations of allergic asthma. We investigated linkages among allergen exposure, immunological measurements, and asthma by examining (1) reservoir dust allergen levels in homes, (2) associations between presence of allergens in homes and sensitization status of resident children, and (3) associations between asthma status and total IgE, atopy (by Phadiatop), and positive allergen-specific tests. METHODS The study protocol was approved by Institutional Review Boards (IRBs) of the University of North Carolina Chapel Hill; Westat, Inc.; and the US Environmental Protection Agency Human Research Protocol Office. Data were collected from questionnaires, serum analyses, and household vacuum dust. Children (n = 205) were predominately African American (AA) (85.4%) and 51.6% were asthmatic. Sera from 185 children and home dust samples (n = 141) were analyzed for total and specific IgE antibodies to allergens from cat and dog dander, cockroach, dust mites, mice, rats, and molds. RESULTS Sixty percent of the homes had detectable levels of three or more dust allergens. The proportions of children with positive allergen-specific IgE tests were dust mite (32%), dog (28%), cat (23%), cockroach (18%), mouse (5%), rat (4%), and molds (24-36%). Children testing positive to a single allergen also had positive responses to other allergens. Those children with positive serum tests for cat, dog, and dust mite lived in homes with detectable levels of cat (51%), dog (90%), and dust mite (Der f 1) (92%) allergens. Correlations between children's specific IgE levels and dust levels were linearly related for dog (p < .04), but not for cat (p = .12) or dust mite (Der f 1) (p = .21). Odds ratios (95% CI) for the associations between asthma and serum-specific IgE were over 1.0 for cat, dog, dust mite (Der f 1), cockroach, and four types of molds. House dust allergen exposure levels, however, exhibited no differences between asthmatic and non-asthmatic homes. CONCLUSIONS Both the co-occurrence of multiple allergens in dust and the high frequency of multiple allergen sensitizations indicate that a broad-based intervention aimed at reducing multiple allergens (pets, pests, and molds) would be more successful than any approach that aimed at reducing one type of allergen.
Collapse
Affiliation(s)
- Ann Houston Williams
- Epidemiology Branch, National Health and Environmental Effects Research Laboratory, United States Environmental Protection Agency, Research Triangle Park, NC 27711, USA.
| | | | | | | | | | | | | |
Collapse
|
20
|
[Indoor air quality in schools]. Arch Pediatr 2011; 18:789-96. [PMID: 21621987 DOI: 10.1016/j.arcped.2011.04.020] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2009] [Revised: 11/27/2010] [Accepted: 04/15/2011] [Indexed: 11/23/2022]
Abstract
Indoor air quality in schools has received particular attention over the past several years. Children are considered as one of the most sensitive groups to atmospheric pollution because their bodies are actively growing and they breathe higher volumes of air relative to their body weights than adults do. They also spend more time in school or group structures (preschools, day nurseries) than in any indoor environments other than the home. The analysis of children's exposure to air pollution at school requires the identification of the main pollutant sources present in these educational institutions. Both a strong contribution of outdoor pollution and a very specific pollution bound to school activities such as the use of paints, markers, glues, and manufactured ink eraser pens, exist. The ventilation in school buildings also plays an important role in air quality. A higher air exchange may improve thermal comfort and air quality. The cause of indoor air pollution is a combinatory effect of physical, chemical, and biological factors, and the adequacy of ventilation in the environment. Several pollutants have been reported to exist in classrooms such as bacteria, molds, volatile organic compounds, persistent organic pollutants and microparticles. There is a correlation between the concentrations of the pollutants and onset of health problems in schoolchildren. We observe predominantly respiratory symptoms as well as a prevalence of respiratory diseases such as asthma and allergies. This study shows that poor indoor air quality affects children's health.
Collapse
|
21
|
Cai GH, Hashim JH, Hashim Z, Ali F, Bloom E, Larsson L, Lampa E, Norbäck D. Fungal DNA, allergens, mycotoxins and associations with asthmatic symptoms among pupils in schools from Johor Bahru, Malaysia. Pediatr Allergy Immunol 2011; 22:290-7. [PMID: 21457336 DOI: 10.1111/j.1399-3038.2010.01127.x] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
While there is a large variation of prevalence of asthma symptoms worldwide, what we do know is that it is on the rise in developing countries. However, there are few studies on allergens, moulds and mycotoxin exposure in schools in tropical countries. The aims were to measure selected fungal DNA, furry pet allergens and mycotoxins in dust samples from schools in Malaysia and to study associations with pupils' respiratory health effects. Eight secondary schools and 32 classrooms in Johor Bahru, Malaysia were randomly selected. A questionnaire with standardized questions was used for health assessment in 15 randomly selected pupils from each class. The school buildings were inspected and both indoor and outdoor climate were measured. Dust samples were collected by cotton swabs and Petri dishes for fungal DNA, mycotoxins and allergens analysis. The participation rate was 96% (462/480 invited pupils), with a mean age of 14 yr (range 14-16). The pupils mostly reported daytime breathlessness (41%), parental asthma or allergy (22%), pollen or pet allergy (21%) and doctor-diagnosed asthma (13%) but rarely reported night-time breathlessness (7%), asthma in the last 12 months (3%), medication for asthma (4%) or smoking (5%). The inspection showed that no school had any mechanical ventilation system, but all classrooms had openable windows that were kept open during lectures. The mean building age was 16 yr (range 3-40) and the mean indoor and outdoor CO(2) levels were 492 ppm and 408 ppm, respectively. The mean values of indoor and outdoor temperature and relative humidity were the same, 29°C and 70% respectively. In cotton swab dust samples, the Geometric Mean (GM) value for total fungal DNA and Aspergillus/Penicillium (Asp/Pen) DNA in swab samples (Cell Equivalents (CE)/m(2)) was 5.7*10(8) and 0.5*10(8), respectively. The arithmetic mean (CE/m(2)) for Aspergillus versicolor DNA was 8780, Stachybotrys chartarum DNA was 26 and Streptomyces DNA was 893. The arithmetic means (pg/m(2)) for the mycotoxins sterigmatocystin and verrucarol were 2547 and 17, respectively. In Petri dish dust samples, the GM value for total fungal DNA and Asp/Pen DNA (CE/m(2) per day) was 9.2*10(6) and 1.6*10(6), respectively. The arithmetic mean (CE/m(2) per day) for A. versicolor DNA was 1478, S. chartarum DNA was 105 and Streptomyces DNA was 1271, respectively. The GM value for cat (Fel d1) allergen was 5.9 ng/m(2) per day. There were positive associations between A. versicolor DNA, wheeze and daytime breathlessness and between Streptomyces DNA and doctor-diagnosed asthma. However, the associations were inverse between S. chartarum DNA and daytime breathlessness and between verrucarol and daytime breathlessness. In conclusion, fungal DNA and cat allergen contamination were common in schools from Malaysia and there was a high prevalence of respiratory symptoms among pupils. Moreover, there were associations between levels of some fungal DNA and reported respiratory health in the pupils.
Collapse
Affiliation(s)
- Gui-Hong Cai
- Deparment of Medical Science, Occupational and Environmental Medicine, University Hospital, Uppsala University, Uppsala, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Segundo GRS, Sopelete MC, Terra SA, Pereira FL, Justino CM, Silva DADO, Taketomi EA. Diversity of allergen exposure: implications for the efficacy of environmental control. Braz J Otorhinolaryngol 2010; 75:311-6. [PMID: 19575122 PMCID: PMC9450745 DOI: 10.1016/s1808-8694(15)30796-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2007] [Accepted: 04/14/2007] [Indexed: 11/25/2022] Open
Abstract
The prevalence of allergic diseases such as asthma, rhinitis, allergic conjunctivitis and atopic dermatitis has increased in the last decades. The relationship between allergen exposure, atopic sensitization and development of allergic diseases is widely described in the literature. Aim To evaluate measures for reducing allergen exposure as part of the treatment of allergic diseases. Methods An analysis was made of previous studies on allergen exposure done with a similar methodology in the central region of Brazil; the study included homes, hotels, cinemas, cars, taxis, buses and scholar transportation. Results High levels of Der p 1 and Der f 1 mite allergens were found in a large proportion of the sample in most of the environments included in those studies; there were higher levels of pet allergens in cars and school transportation vehicles. Conclusion The diversity of allergen exposure demonstrates the need for education about allergic diseases for patients and their families, as well as measures of reducing allergens in homes. This should be part of a global strategy of the management of allergic diseases, given that individuals live in society, not only in their houses.
Collapse
|
23
|
Jones SE, Wheeler LS, Smith AM, McManus T. Adherence to National Asthma Education and Prevention Program's "How Asthma-Friendly Is Your School?" recommendations. J Sch Nurs 2010; 25:382-94. [PMID: 19770490 DOI: 10.1177/1059840509343292] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
School health policies and programs provide the framework for a safe and supportive environment for students with asthma. School Health Policies and Programs Study 2006 data were examined to assess whether schools nationwide have policies and programs consistent with the "How Asthma-Friendly Is Your School?" checklist from the National Asthma Education and Prevention Program. Adherence to some of the recommendations on the checklist was high. For example, 80% or more of schools allowed students to carry and self-administer asthma medications, and obtained and kept asthma action plans. For other recommendations, however, far fewer schools had the recommended polices or programs; most notably, less than one third of schools had a full-time Registered Nurse. Improvements in many school policies and programs are needed so that students have a safe and supportive school environment to help them control their asthma while away from home.
Collapse
|
24
|
Richmond TK, Subramanian SV. School variation in asthma: compositional or contextual? PLoS One 2009; 4:e8512. [PMID: 20041121 PMCID: PMC2795778 DOI: 10.1371/journal.pone.0008512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2009] [Accepted: 11/22/2009] [Indexed: 11/18/2022] Open
Abstract
Background Childhood asthma prevalence and morbidity have been shown to vary by neighborhood. Less is known about between-school variation in asthma prevalence and whether it exists beyond what one might expect due to students at higher risk of asthma clustering within different schools. Our objective was to determine whether between-school variation in asthma prevalence exists and if so, if it is related to the differential distribution of individual risk factors for and correlates of asthma or to contextual influences of schools. Methods Cross-sectional analysis of 16,640 teens in grades 7–12 in Wave 1 (data collected in 1994–5) of the National Longitudinal Study of Adolescent Health. Outcome was current diagnosis of asthma as reported by respondents' parents. Two-level random effects models were used to assess the contribution of schools to the variance in asthma prevalence before and after controlling for individual attributes. Results The highest quartile schools had mean asthma prevalence of 21.9% compared to the lowest quartile schools with mean asthma prevalence of 7.1%. In our null model, the school contributed significantly to the variance in asthma ( = 0.27, CI: 0.20, 0.35). Controlling for individual, school and neighborhood attributes reduced the between-school variance modestly ( = 0.19 CI: 0.13–0.29). Conclusion Significant between-school variation in current asthma prevalence exists even after controlling for the individual, school and neighborhood factors. This provides evidence for school level contextual influences on asthma. Further research is needed to determine potential mechanisms through which schools may influence asthma outcomes.
Collapse
Affiliation(s)
- Tracy K Richmond
- Division of Adolescent Medicine, Children's Hospital Boston, Boston, Massachusetts, United States of America.
| | | |
Collapse
|
25
|
Tranter DC, Wobbema AT, Norlien K, Dorschner DF. Indoor allergens in Minnesota schools and child care centers. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2009; 6:582-591. [PMID: 19585331 DOI: 10.1080/15459620903103454] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Elevated concentrations of allergens in the indoor environment may cause allergic sensitization and symptoms. Occupant exposure to indoor allergens in educational facilities should and can be controlled. This study (1) assessed the presence of indoor allergens in Minnesota schools and child care centers, (2) characterized the distribution of allergens in different materials, and (3) evaluated the effect of building and maintenance interventions on allergen concentrations. Settled dust samples were collected from carpet, vinyl tile floors, and upholstered furniture in six schools and seven child care centers before and after interventions. Interventions included changes to cleaning, ventilation, entry mats, furnishings, flooring, and classroom items. The amount of total dust, culturable fungi, and indoor allergens--cockroach, dust mite, cat, and dog--were quantified in the dust samples. Cockroach and dust mite allergens were generally low and below the detection limit, but one dust mite allergen was detected in some areas. Cat and dog allergens were frequently detected at elevated levels, with half the samples above the provisional sensitization risk thresholds and a few samples above the symptom thresholds. Allergen concentrations were highest in upholstered furniture, followed by carpeting and then vinyl floor tile. Cat and dog allergens were lower after the interventions. Cat and dog allergens, but not dust mite and cockroach allergens, seem to be ubiquitous in child care and elementary schools of the U.S. Midwest. These allergens may contribute to sensitization in atopic individuals and occasionally cause symptoms in sensitized allergic individuals. Fleecy materials that are not adequately cleaned, such as upholstered furniture, appear to be the most significant allergen reservoirs. Modest environmental interventions can be implemented by building staff, which should result in lower allergen concentrations.
Collapse
Affiliation(s)
- Daniel C Tranter
- Minnesota Department of Health, Division of Environmental Health, P.O. Box 64975, St. Paul, MN 55164-0975, USA.
| | | | | | | |
Collapse
|
26
|
Salo PM, Sever ML, Zeldin DC. Indoor allergens in school and day care environments. J Allergy Clin Immunol 2009; 124:185-92, 192.e1-9; quiz 193-4. [PMID: 19577284 DOI: 10.1016/j.jaci.2009.05.012] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2009] [Revised: 05/05/2009] [Accepted: 05/06/2009] [Indexed: 11/17/2022]
Abstract
Most studies that have examined exposure to indoor allergens have focused on home environments. However, allergen exposures can be encountered in environments other than the home. For example, many children spend a large part of their time in schools and day care facilities. Over the past 2 decades, a large number of studies have been conducted in school and day care environments. However, the role of indoor exposures in allergy and asthma development or morbidity in these settings is not well characterized. The purpose of this review is to evaluate the importance of indoor allergen exposures in school and day care settings. We summarize the key findings from recent scientific literature, describe exposure characteristics, discuss the role of these exposures in relation to asthma and allergy symptoms, and provide information on the effectiveness of published interventions.
Collapse
Affiliation(s)
- Päivi M Salo
- National Institute of Environmental Health Sciences, National Institutes of Health, Research Triangle Park, NC 27709, USA
| | | | | |
Collapse
|
27
|
Nalyanya G, Gore JC, Linker HM, Schal C. German cockroach allergen levels in North Carolina schools: comparison of integrated pest management and conventional cockroach control. JOURNAL OF MEDICAL ENTOMOLOGY 2009; 46:420-427. [PMID: 19496408 DOI: 10.1603/033.046.0302] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Cockroach suppression is fundamental to cockroach allergen mitigation in infested homes. The effects of various cockroach control strategies on cockroach populations and allergen concentration have not been examined in schools. This study was conducted to compare the effectiveness of integrated pest management (IPM) and conventional pest control in controlling German cockroach (Blattella germanica L.) infestations and concentrations of the cockroach allergen Bla g 1 in public school buildings. Two school districts included six schools that used conventional pest control and one district included seven schools that used IPM to control pests. Cockroach traps were deployed to assess the level of infestation, settled dust samples were collected in food service areas, classrooms, and other school areas, and the Bla g 1 allergen was quantified by ELISA. Both cockroach counts and Bla g 1 concentrations were dependent on the pest control approach, with highly significant differences between IPM-treated schools and conventionally treated schools in both the cockroach mean trap counts (0 versus 82.6 +/- 17.3 cockroaches/trap/wk, respectively) and in the amount of Bla g 1 in dust samples (2.8 +/- 0.3 versus 30.6 +/- 3.4 U/g dust). Cockroaches and Bla g 1 were primarily associated with food preparation and food service areas and much less with classrooms and offices. Our data extend recent findings from studies in homes, showing that cockroach allergens can be reduced by cockroach elimination alone or by integrating several tactics including education, cleaning, and pest control. IPM is not only effective at controlling cockroaches but also can lead to long-term reductions in cockroach allergen concentrations, resulting in a healthier environment for students and school personnel.
Collapse
Affiliation(s)
- Godfrey Nalyanya
- Department of Entomology, Box 7613, North Carolina State University, Raleigh, NC 27695-7613, USA
| | | | | | | |
Collapse
|
28
|
Segundo GRS, Sopelete MC, Terra SA, Pereira FL, Justino CM, Silva DADO, Taketomi EA. Diversidade da exposição alergênica: implicações na obtenção da eficácia do controle ambiental. ACTA ACUST UNITED AC 2009. [DOI: 10.1590/s0034-72992009000200025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
As doenças alérgicas, como a asma, rinite, conjuntivite alérgica e a dermatite atópica têm apresentado um aumento na sua prevalência nas últimas décadas. A relação entre exposição alergênica, sensibilização atópica e desenvolvimento de doenças alérgicas são amplamente descrita na literatura. OBJETIVO: Discutir a dificuldade no controle ambiental da exposição alergênica como parte do tratamento das doenças alérgicas. MÉTODOS: Analisar trabalhos de exposição alergênica realizados com metodologia similar na região central do Brasil, incluindo casas, hotéis, cinemas, carros, táxis, ônibus e transporte escolar. RESULTADOS: Níveis elevados dos alérgenos do grupo 1 de Dermatophagoides pteronyssinus (Der p 1) e de D. farinae (Der f 1), capazes de causar sensibilização e exacerbação de sintomas foram encontrados na maioria dos ambientes estudados em uma larga proporção das amostras, enquanto os alérgenos de animais domésticos atingiram maiores níveis em carros e veículos de transporte escolar. CONCLUSÃO: A diversidade da exposição alergênica mostra a necessidade de uma compreensão da doença alérgica pelos pacientes e familiares, e que as medidas de controle do ambiente doméstico fazem parte de uma estratégia global do tratamento das doenças alérgicas, uma vez que os indivíduos vivem em uma sociedade e não isoladas no interior de seus domicílios.
Collapse
|
29
|
Stranger M, Potgieter-Vermaak SS, Van Grieken R. Characterization of indoor air quality in primary schools in Antwerp, Belgium. INDOOR AIR 2008; 18:454-463. [PMID: 18823343 DOI: 10.1111/j.1600-0668.2008.00545.x] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
UNLABELLED The indoor air quality of 27 primary schools located in the city centre and suburbs of Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the various pollutant levels. Indoor:outdoor ratios and the building and classroom characteristics of each school were investigated. This paper presents results on indoor and local outdoor PM2.5 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S, and Cl, and its black smoke content. In addition, indoor and local outdoor levels of the gases NO2, SO2, O3, and BTEX (benzene, toluene, ethyl benzene, and xylene isomers) were determined. Black smoke, NO2, SO2 and O3, occurred at indoor:outdoor ratios below unity, indicating their significant outdoor sources. No linear correlation was established between indoor and outdoor levels for PM2.5 mass concentrations and BTEX; their indoor:outdoor ratios exceeded unity except for benzene. Classroom PM2.5 occurred with a different elemental composition than local outdoor PM2.5. The re-suspension of dust because of room occupation is probably the main contributor for the I/O ratios higher than 1 reported for elements typically constituting dust particles. Finally, increased benzene concentrations were reported for classrooms located at the lower levels. PRACTICAL IMPLICATIONS The elevated indoor PM2.5, and BTEX concentrations in primary school classrooms, exceeding the ambient concentrations, raise concerns about possible adverse health effects on susceptible children. This is aggravated by the presence of carpets and in the case of classrooms at lower levels. Analysis of PM2.5's elemental composition indicated a considerable contribution of soil dust to indoor PM2.5 mass. In order to set adequate threshold values and guidelines, detailed information on the health impact of specific PM2.5 composites is needed. The results suggest that local outdoor air concentrations measurements do not provide an accurate estimation of children's personal exposures to the identified air pollutants inside classrooms.
Collapse
Affiliation(s)
- M Stranger
- Department of Chemistry, University of Antwerp, Antwerp, Belgium.
| | | | | |
Collapse
|
30
|
Zhao Z, Sebastian A, Larsson L, Wang Z, Zhang Z, Norbäck D. Asthmatic symptoms among pupils in relation to microbial dust exposure in schools in Taiyuan, China. Pediatr Allergy Immunol 2008; 19:455-65. [PMID: 18221461 DOI: 10.1111/j.1399-3038.2007.00664.x] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Microbial exposure has been indicated as significant in the development of asthma and allergy among children. The aim of the study was to test whether microbial exposure and allergens in the school environment are associated with asthmatic symptoms in pupils. Data on asthmatic symptoms and respiratory infections were collected through a questionnaire survey among 1993 pupils aged 11-15 yr in 10 randomly selected schools in Taiyuan, China. Settled dust in classrooms was analysed using tandem gas chromatography-mass spectrometry for 3-hydroxy fatty acids, marker of lipopolysaccharide (LPS) from endotoxin, muramic acid (MuA), marker of bacteria and ergosterol (Erg) for fungi, quantifying both culturable and non-culturable microbes. A total of 29.8% reported daytime attacks of breathlessness, 8.4% wheeze and 1.2% had doctor's diagnosed asthma. Generally, MuA was negatively associated with wheeze and daytime attacks of breathlessness, the latter of which was negatively associated with Erg to a weaker extent. Total concentration of LPS was positively associated with daytime attacks of breathlessness, but shorter lengths of LPS, C10, C12 and C14 LPS were negatively associated with either wheezing or daytime attacks of breathlessness. For MuA and C10 and C12 of LPS, the associations were independent of airborne allergens and classroom crowdedness, and even independent of the other two microbial markers for MuA. Microbial exposure indicated by certain chemical markers (e.g. MuA) could be protective for asthmatic symptoms, but for LPS (endotoxin), the picture is more complex, varying by different lengths of fatty acids of LPS.
Collapse
Affiliation(s)
- Zhuohui Zhao
- Department of Occupational and Environmental Medicine, University Hospital and Uppsala University, Uppsala, Sweden.
| | | | | | | | | | | |
Collapse
|
31
|
Jones SE, Axelrad R, Wattigney WA. Healthy and safe school environment, Part II, Physical school environment: results from the School Health Policies and Programs Study 2006. THE JOURNAL OF SCHOOL HEALTH 2007; 77:544-56. [PMID: 17908107 DOI: 10.1111/j.1746-1561.2007.00234.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
BACKGROUND As society continues to focus on the importance of academic achievement, the physical environment of schools should be addressed as 1 of the critical factors that influence academic outcomes. The School Health Policies and Programs Study (SHPPS) 2006 provides, for the first time, a comprehensive look at the extent to which schools have health-promoting physical school environment policies and programs. METHODS The Centers for Disease Control and Prevention conducts the SHPPS every 6 years. In 2006, computer-assisted telephone interviews or self-administered mail questionnaires were completed by state education agency personnel in all 50 states and the District of Columbia and among a nationally representative sample of school districts (n=424). Computer-assisted personal interviews were conducted with personnel in a nationally representative sample of elementary, middle, and high schools (n=992). RESULTS One third (35.4%) of districts and 51.4% of schools had an indoor air quality management program; 35.3% of districts had a school bus engine-idling reduction program; most districts and schools had a policy or plan for how to use, label, store, dispose of, and reduce the use of hazardous materials; 24.5% of states required districts or schools to follow an integrated pest management program; and 13.4% of districts had a policy to include green design when building new school buildings or renovating existing buildings. CONCLUSIONS SHPPS 2006 results can guide education and health agency actions in developing and implementing evidence-based tools, policies, programs, and interventions to ensure a safe and healthy physical school environment.
Collapse
Affiliation(s)
- Sherry Everett Jones
- Division of Adolescent and School Health, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control and Prevention, 4770 Buford Highway, NE, MS-K33, Atlanta, GA 30341, USA.
| | | | | |
Collapse
|
32
|
Simplício EC, Silva DAO, Braga IA, Sopelete MC, Sung SJ, Taketomi EA. Mite and pet allergen exposure in hotels in Uberlândia, Midwestern Brazil. INDOOR AIR 2007; 17:278-83. [PMID: 17661924 DOI: 10.1111/j.1600-0668.2006.00470.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
UNLABELLED Mite allergens are involved in airway sensitization and allergic diseases. We evaluated the exposure to house dust-mite (Der p 1 and Der f 1) and pet (Fel d 1 and Can f 1) allergens in hotels in Uberlândia, Midwestern Brazil. A total of 140 dust samples were collected from bedding (n = 98) and carpet (n = 42) of bedrooms in 20 hotels enrolled for this study. Geometric mean (GM) levels of Der f 1 (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) were significantly higher than Der p 1 (0.15 microg/g of dust; 95% CI: 0.13-0.18 microg/g) in bedding dust samples (P < 0.001), regardless of the hotel classes. Der f 1 levels were significantly higher in bedding (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) than carpet (6.32 microg/g of dust; 95% CI: 4.31-9.26 microg/g) dust samples (P < 0.05). High levels of Der f 1 (>10 microg/g of dust) were found in 58%, 76%, and 69% of dust samples from Simple, Economical, and Tourist/Superior hotels, respectively, while GM levels of Fel d 1 (0.11 microg/g of dust; 95% CI: 0.09-0.14 microg/g) and Can f 1 (0.30 microg/g of dust; 95% CI: 0.20-0.44 microg/g) were relatively low. These results indicate that Der f 1 is the predominant allergen in hotels in Uberlândia, especially in bedding dust samples, regardless of the hotel classes and could represent an important risk factor for exacerbation of allergic symptoms in previously mite-sensitized guests. PRACTICAL IMPLICATIONS Mites and pets are important sources of indoor allergens. Most people spend the greatest part of their time indoors. Hotels can constitute an important allergen reservoir of the indoor environment and could represent an important risk for exacerbation of allergic symptoms in previously sensitized guests. Thus, hotels should also be included for planning indoor allergen avoidance as part of a global management strategy, especially in patients with respiratory allergy.
Collapse
Affiliation(s)
- E C Simplício
- Laboratory of Allergy and Clinical Immunology, Biomedical Science Institute, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | | | | | | | | | | |
Collapse
|
33
|
Kim JL, Elfman L, Norbäck D. Respiratory symptoms, asthma and allergen levels in schools--comparison between Korea and Sweden. INDOOR AIR 2007; 17:122-9. [PMID: 17391234 DOI: 10.1111/j.1600-0668.2006.00460.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
UNLABELLED We studied reports on respiratory symptoms, asthma and atopic sensitisation in relation to allergen contamination in Korean schools and compared with data from a previous Swedish study performed in eight primary schools. Korean pupils (n = 2365) in 12 primary schools first completed a questionnaire. Then airborne and settled dust were collected from 34 classrooms and analyzed for allergens by ELISA. In both countries, boys reported more symptoms. The prevalence of wheeze was similar, while daytime [odds ratio (OR) = 14.0, 95% confidence interval (CI) = 9.0-21.9] and nocturnal breathlessness (OR = 3.1, 95% CI = 1.5-6.4) were much higher among Korean students. In Korean schools, dog allergen (Can f 1) was the most common followed by mite allergen (Der f 1), while cat (Fel d 1), dog, and horse allergen (Equ cx) were abundant in Sweden. Moreover, CO(2) levels were high in most Korean schools (range 907-4113 ppm). There was an association between allergen levels in dust and air samples, and number of pet-keepers in the classrooms. In conclusion, allergen contamination in Korean schools may be an important public issue. PRACTICAL IMPLICATIONS This study showed that furry pet allergen contamination was common in both Korean and Swedish schools. In addition, house dust-mite (Der f 1) allergen contamination was common in Korean schools, probably because of transport of allergen from other environments. Transfer should therefore be minimized. Korean schools had high CO(2) levels and the concept of mechanical ventilation should be introduced. Measurement of airborne allergen levels is quite new and seems to be a more convenient and correct way to monitor allergen exposure in classrooms.
Collapse
Affiliation(s)
- J L Kim
- Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University and University Hospital, Uppsala, Sweden.
| | | | | |
Collapse
|
34
|
Gore JC, Schal C. Cockroach allergen biology and mitigation in the indoor environment. ANNUAL REVIEW OF ENTOMOLOGY 2007; 52:439-63. [PMID: 17163801 DOI: 10.1146/annurev.ento.52.110405.091313] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
For nearly a half century, cockroaches have been recognized as a major cause of asthma morbidity in the urban, inner-city environment. Several cockroach-produced allergens have been identified and characterized, and a few have been produced as recombinant proteins. Recent research has moved beyond clinical, patient-based investigations to a more entomological perspective that addresses the production, physiological regulation, and developmental expression of cockroach allergens, thus providing insight into their functional biology and their relationship to current cockroach control strategies. Although successful removal of cockroach allergens from the infested environment has been difficult to accomplish with remedial sanitation, large-scale reductions in cockroach allergens below clinically relevant thresholds have recently been realized through suppression of cockroach populations. Here we review the current understanding of cockroach allergen biology and the demographics associated with human exposure and sensitization. We also critically evaluate allergen mitigation studies from an entomological perspective, highlighting disparities between successful and failed attempts to lessen the cockroach allergen burden in homes.
Collapse
Affiliation(s)
- J Chad Gore
- Department of Entomology, North Carolina State University, Raleigh, North Carolina 27695-7613, USA.
| | | |
Collapse
|
35
|
Zhao ZH, Elfman L, Wang ZH, Zhang Z, Norbäck D. A comparative study of asthma, pollen, cat and dog allergy among pupils and allergen levels in schools in Taiyuan city, China, and Uppsala, Sweden. INDOOR AIR 2006; 16:404-13. [PMID: 17100662 DOI: 10.1111/j.1600-0668.2006.00433.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We compared the school environment, asthma and allergy in 10 schools in Taiyuan, China, with eight schools in Uppsala, Sweden. In total 2193 pupils (mean age 13 years) participated. Chinese pupils had more respiratory symptoms, particularly daytime breathlessness after exercise (29.8% vs. 7.1%; P < 0.001), while cat allergy (1.2% vs. 6.6%; P < 0.001) and dog allergy (1.3% vs. 4.0%; P < 0.01) was less common. Cumulative incidence of asthma (1.8% vs. 9.5%; P < 0.001) and doctor's diagnosed asthma (1.2% vs. 9.0%; P < 0.001) were less common in China, indicating an under-diagnosis of asthma. Chinese classrooms were colder (mean 14.7 vs. 21.4 degrees C), more humid (mean 42% vs. 31% RH) and had higher CO2-levels (mean 2211 vs. 761 ppm). Levels of cat (Fel d1), dog (Can f1) allergens were low in settled dust from China (< 200 ng/g dust), but high in airborne dust on Petri-dishes (GM 16.8 ng/m2/day for Fel d1 and 17.7 for Can f1). The Swedish settled dust contained cat, dog and horse allergens in high levels (median 1300 ng/g, 1650 ng/g, 1250 U/g dust, respectively). In conclusion, there were large differences in the school environment, and in respiratory symptom and allergy. Allergen measurements in settled dust only may largely underestimate the classroom exposure. Practical Implications There is a need to improve the school environment, both in China and Sweden. The Swedish schools contained high levels of cat, dog and horse allergens and more amounts of open shelves and textiles that can accumulate dust and allergens. The air measurements indicated that Chinese schools may contain significant amounts of cat and dog allergen, and analysis of settled dust only may not reflect the true allergen exposure. Since the Chinese schools had no mechanical ventilation, they could not fulfill the ventilation standard in winter, and hence there is a need for improving the ventilation. The great discrepancy between respiratory symptoms and reports on asthma, and the high prevalence of attacks of breathlessness without wheeze, may have implication for future questionnaire studies on asthma in China.
Collapse
Affiliation(s)
- Z H Zhao
- Department of Medical Sciences, Uppsala University and University Hospital, Uppsala, Sweden.
| | | | | | | | | |
Collapse
|
36
|
Abstract
PURPOSE OF REVIEW Asthma is an important health problem in school-aged children and schools seem an obvious site to find and work with under-recognized and under-treated asthma. Teachers and coaches often must deal with asthma-related symptoms or emergencies requiring knowledge, skills, and written plans and policies. In 2005, school-based asthma work focused on two areas: identification of unrecognized asthma and management of under-treated asthma. RECENT FINDINGS Effective school-based screening requires a simple, effective screening tool. Three new asthma screening tools continue to identify more false-positive than true positive cases of asthma. Public health experts question whether asthma even fits the usual criteria for 'screening' because it does not have an asymptomatic phase. 'Case-finding' is presented as a better use of resources, allowing schools to focus on children with asthma that has been diagnosed but remains symptomatic. No school-based program based on letters, reminders, or recommendations sent to parents or community physicians changed asthma care. Three reports describe programs designed to supplement usual asthma care by providing in-school interventions, but none appeared ready for implementation in all schools in the USA. A major barrier was the continuing lack of school nurses, who must have asthma-related education and medical support to provide school-based asthma management. SUMMARY Schools continue to be a site for asthma interventions but few of the programs, even the most intensive, influence children's asthma-related health. Most programs require modifications and further evaluation, and all require careful assessment of the burden on schools.
Collapse
Affiliation(s)
- Barbara P Yawn
- Olmsted Medical Center and Department of Family and Community Health, University of Minnesota, Rochester, Minnesota 55904, USA.
| |
Collapse
|
37
|
Abstract
Of the four modes of treating human allergic disease, avoidance or separation of the allergic patient from the allergen source is most effective and least expensive. The clinical immunology laboratory has established efficient and inexpensive "reservoir" dust sampling and processing procedures to obtain a surface dust specimen that reflects the allergen burden of the environment. Following extraction, allergens are quantified by reproducible, validated immunoenzymetric assays for the quantification of "indicator" aeroallergen levels in home, school, and work environments. In this paper, the strategies and methods for collecting and processing dust samples are discussed, and assays are reviewed for quantifying indoor aeroallergen exposure from dust mites (Der p 1 and 2, Der f 1 and 2), animals (cat: Fel d 1; dog: Can f 1; mouse: Mus m 1; rat: Rat n 1), and insects (cockroach: Bla g 1 and 2). Accurate quantification of the levels of allergen in indoor environments facilitates avoidance therapy by identifying environmental risk factors for asthma and allergy exacerbation and allowing the allergic patient to monitor the effectiveness of environmental remediation actions.
Collapse
|
38
|
Instanes C, Hetland G, Berntsen S, Løvik M, Nafstad P. Allergens and endotoxin in settled dust from day-care centers and schools in Oslo, Norway. INDOOR AIR 2005; 15:356-62. [PMID: 16108908 DOI: 10.1111/j.1600-0668.2005.00381.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
UNLABELLED Allergy to indoor allergens can cause frequent and severe health problems in children. Because little is known about the content of allergens in the indoor environments in Norway, we wanted to assess the levels of cat, dog and mite allergens in schools and day-care centers in Oslo. Allergen levels in dust samples from 155 classrooms and 81 day-care units were measured using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Additionally, we measured the levels of endotoxin in 31 day-care units, using the limulus amebocyte lysate test. Most of the dust samples contained detectable amounts of cat and dog allergens. In mattress and floor dust (day-care centers), and curtain and floor dust (schools) the median Fel d 1 levels were 0.17, 0.002, 0.02 and 0.079 microg/m2, while the median Can f 1 levels were 1.7, 0.03, 0.1 and 0.69 microg/m2, respectively. Levels of cat and dog allergens in school floor dust were associated with the number of pupils with animals at home. In contrast, <1% of the samples had measurable levels of the mite allergen Der p 1. Moreover, the levels of endotoxin tended to be higher in dust from floors (1.4 ng/m2) compared with that from mattresses (0.9 ng/m2). PRACTICAL IMPLICATIONS To reduce allergen exposure, allergic individuals should be placed in the classes/rooms with the fewest pet owners. Moreover, mattresses in day-care centers are major reservoirs of cat and dog allergens and should be cleaned frequently.
Collapse
Affiliation(s)
- C Instanes
- Division of Environmental Medicine, Norwegian Institute of Public Health, Oslo, Norway.
| | | | | | | | | |
Collapse
|