Siddique A, Al-Shamlan MYM, Al-Romaihi HE, Khwaja HA. Beyond the outdoors: indoor air quality guidelines and standards - challenges, inequalities, and the path forward. REVIEWS ON ENVIRONMENTAL HEALTH 2023; 0:reveh-2023-0150. [PMID: 38148484 DOI: 10.1515/reveh-2023-0150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 11/28/2023] [Indexed: 12/28/2023]
Abstract
In the last few decades, indoor air quality (IAQ) has become a major threat to public health. It is the fifth leading cause of premature death globally. It has been estimated that people spend ∼90 % of their time in an indoor environment. Consequently, IAQ has significant health effects. Although IAQ-related standards and guidelines, policies, and monitoring plans have been developed in a few countries, there remain several global inequalities and challenges. This review paper aims to comprehensively synthesize the current status of widely accepted IAQ guidelines and standards. It analyzes their global implementation and effectiveness to offer insights into challenges and disparities in IAQ policies and practices. However, the complexity of domestic environments and the diversity of international standards impede effective implementation. This manuscript evaluates international, national, and regional IAQ guidelines, emphasizing similarities and differences. In addition, it highlights knowledge gaps and challenges, urging the international scientific community, policymakers, and stakeholders to collaborate to advance IAQ standards and guidelines. The analysis evaluates the efficacy of guidelines, identifies deficiencies, and offers recommendations for the future of domestic air quality standards.
Collapse
Affiliation(s)
- Azhar Siddique
- Qatar Environment and Energy Research Institute, Hamad Bin Khalifa University (HBKU), Ar-Rayyan, Qatar
| | - Maryam Y M Al-Shamlan
- Health Protection and Communicable Disease Control Department, Ministry of Public Health (MoPH), Doha, Qatar
- College of Arts and Sciences, Qatar University, Doha, Qatar
| | - Hamad E Al-Romaihi
- Health Protection and Communicable Disease Control Department, Ministry of Public Health (MoPH), Doha, Qatar
| | - Haider A Khwaja
- Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY, USA
| |
Collapse
|
2
|
Sensory Perception Mechanism for Preparing the Combinations of Stimuli Operation in the Architectural Experience. SUSTAINABILITY 2022. [DOI: 10.3390/su14137885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Sensory stimuli in an architectural space play an important role in the human perception of the indoor environment, no matter whether they are static or dynamic, isolated, or combined. By enhancing some perceptions in the sensory stimuli, the overall perceptions of an architectural space can be improved, especially for an intelligent architectural space. As yet, there are few studies reported about the sensory perception mechanism for the sensory stimuli operation in the architectural experience. In this research, a wooden micro building was prepared for the study of the sensitivity level of participants to various sensory stimuli in the same and in different sensory domains. Participants’ visual, auditory, olfactory, tactile and kinaesthesia perceptions were discussed statistically in terms of the sensitivity level. Based on the study, the effect of a single dynamic sensory stimulus (a dynamically coloured light) on the participants’ perception was studied in a paper architectural model from two aspects including preference and emotion. The dynamically coloured light was discussed statistically in terms of the level of preference. The study showed that there are significant differences among participants’ levels of sensitivity to the different sensory domains and to the different sensory stimuli. In particular, the sensitivity level to the stimulus that is the colour of a space is the highest of all stimuli. As a single changing sensory stimulus, a dynamically coloured light can lead to significant mood fluctuations and changes in the preference level. In particular, yellow is the favourite colour of light. The object of this study is expected to provide a theoretical foundation that is related to sensory choice, sensory perception enhancement and the combination forms of sensory perceptions. Based on the theoretical foundation, the perception design of overlapped multi-sensory stimuli and a single dynamic stimulus can be conducted to improve the quality of the indoor environment of normal and intelligent multi-sensory architecture.
Collapse
|
3
|
Nakayama Y, Suzuki N, Nakaoka H, Tsumura K, Takaguchi K, Takaya K, Hanazato M, Todaka E, Mori C. Assessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph181910246. [PMID: 34639547 PMCID: PMC8549697 DOI: 10.3390/ijerph181910246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 09/24/2021] [Accepted: 09/28/2021] [Indexed: 12/12/2022]
Abstract
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (ΣVOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of ΣVOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between ΣVOCs and participants’ relaxation (OR: 2.86, 95%CI: 1.24–6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of ΣVOCs than that with higher levels (OR: 3.03, 95%CI: 1.23–7.50). Therefore, the reduction of ΣVOCs and odors in indoor air would have an effect, which is the promotion of relaxation.
Collapse
Affiliation(s)
- Yoshitake Nakayama
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
- Correspondence: ; Tel.: +81-4-7137-8200
| | - Norimichi Suzuki
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
| | - Hiroko Nakaoka
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
- Department of Bioenvironmental Medicine, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan
| | - Kayo Tsumura
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
- Graduate School of Medical and Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan
| | - Kohki Takaguchi
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
| | - Kazunari Takaya
- National Institute of Occupational Safety and Health, 6-21-1 Nagao, Tama-ku, Kawasaki 214-8585, Japan;
| | - Masamichi Hanazato
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
| | - Emiko Todaka
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
- Department of Bioenvironmental Medicine, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan
| | - Chisato Mori
- Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan; (N.S.); (H.N.); (K.T.); (K.T.); (M.H.); (E.T.); (C.M.)
- Department of Bioenvironmental Medicine, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan
| |
Collapse
|
4
|
Zhang X, Li D, Xie J, Liu J. Environmental perceptions, mental performance, and physiological responses of people with respiratory allergies exposed to reduced Indoor Air Quality. INDOOR AIR 2021; 31:1458-1472. [PMID: 33432603 DOI: 10.1111/ina.12793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 12/24/2020] [Indexed: 06/12/2023]
Abstract
To investigate the need of allergic population for indoor environment quality, exposure effects of poor air quality on subjects with respiratory allergies were compared with those on healthy people, including perceptual responses, health symptoms, mental performance, and physiological responses. The experimental intervention was with and without ventilation at thermally neutral rooms, creating two exposure conditions indicated by CO2 concentration ranges of 502 to 3297 ppm (2438 ± 1527 ppm) and 517 to 5687 ppm (3615 ± 1527 ppm). 63 subjects (32 allergic subjects and 31 non-allergic subjects) were exposed to both conditions for 3 hours. The main results suggested that, compared with healthy people, people with respiratory allergy seem to be more sensitive or less acceptable to reduced air quality polluted by occupants during instantaneous exposure. Besides, the allergic group performed worse in cognitive tests than non-allergic group. After 3 hours of continuous exposure, people with respiratory allergy reported stronger intensity of respiratory irritations and seemed to suffer more inflammation indicated by a higher level of interleukin 1L-1β.
Collapse
Affiliation(s)
- Xiaojing Zhang
- Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Dandan Li
- Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Jingchao Xie
- Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Jiaping Liu
- Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| |
Collapse
|
5
|
Is There Any Difference in Indoor Environmental Perceptions between People with and without Respiratory Allergy? ACTA ACUST UNITED AC 2020. [DOI: 10.1007/978-981-13-9520-8_26] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
6
|
Wolkoff P. The mystery of dry indoor air - An overview. ENVIRONMENT INTERNATIONAL 2018; 121:1058-1065. [PMID: 30389384 DOI: 10.1016/j.envint.2018.10.053] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 10/23/2018] [Accepted: 10/26/2018] [Indexed: 06/08/2023]
Abstract
"Dry air" is a major and abundant indoor air quality complaint in office-like environments. The causality of perceived "dry air" and associated respiratory effects continues to be debated, despite no clear definition of the complaint, yet, has been provided. The perception of "dry air" is semantically confusing without an associated receptor but mimics a proto-state of sensory irritation like a cooling sensation. "Dry air" may also be confused with another common indoor air quality complaint "stuffy air", which mimics the sense of no fresh air and of nasal congestion. Low indoor air humidity (IAH) was dismissed more than four decades ago as cause of "dry air" complaints, rather indoor pollutants was proposed as possible exacerbating causative agents during the cold season. Many studies, however, have shown adverse effects of low IAH and beneficial effects of elevated IAH. In this literature overview, we try to answer, "What is perceived "dry air" in indoor environments and its associated causalities. Many studies have shown that the perception is caused not only by extended exposure to low IAH, but also simultaneously with and possibly exacerbated by indoor air pollutants that aggravate the protective mucous layer in the airways and the eye tear film. Immanent diseases in the nose and airways in the general population may also contribute to the overall complaint rate and including other risk factors like age of the population, use of medication, and external factors like the local ambient humidity. Low IAH may be the single cause of perceived "dry air" in the elderly population, while certain indoor air pollutants may come into play among susceptible people, in addition to baseline contribution of nasal diseases. Thus, perceived "dry air" intercorrelates with dry eyes and throat, certain indoor air pollutants, ambient humidity, low IAH, and nasal diseases.
Collapse
Affiliation(s)
- Peder Wolkoff
- National Research Centre for the Working Environment, Lersø Parkallé 105, DK-2100 Copenhagen, Denmark.
| |
Collapse
|
7
|
Bhargava D, Bhargava K, Al-Abri A, Al-Bassam W, Al-Abri R. Non allergic rhinitis: prevalence, clinical profile and knowledge gaps in literature. Oman Med J 2012; 26:416-20. [PMID: 22253950 DOI: 10.5001/omj.2011.106] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2011] [Accepted: 08/01/2011] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVES Although Nasal symptoms induced by Non-allergic rhinitis| (NAR) are a cause of wide spread morbidity; the disease is trivialized. There is a lack of Epidemiological studies on the prevalence of non-allergic rhinitis. In spite of being one of the commonest conditions presenting to the General practitioner and otolaryngologists, the clinical profile, diagnosis, and management outcomes are unknown. The objectives of the study were to examine the prevalence and clinical profile of non-allergic rhinitis in Oman. Secondary objective was to identify Knowledge gaps in literature with the aim of directing future research. METHODS A cross sectional study of 610 consecutive adult patients presenting to the Ear, Nose and Throat clinic at Sultan Qaboos University Hospital is presented in this paper. The diagnosis of NAR was mainly based on step wise fashion; including a thorough clinical history and exclusion of other causes of rhinitis; all consecutive patients diagnosed with rhinitis (n=113) had a detailed history, nasal endoscopy, nasal smears, CT scans and an antihistamine response trial. The prevalence of NAR with its clinical profile was subsequently determined. Primary research articles and meta-analysis evaluated for the knowledge gap study were identified through MEDLINE search of English language literature published between 2000-2011. RESULTS A total of 610 consecutive patients were studied. The overall prevalence of rhinitis was 18.5% (n=113). The prevalence of NAR was 7.5% (n=46). Cases of allergic rhinitis (5.7%; n=35), Chronic rhinosinusitis (1.8%; n=11), and miscellaneous causes (3.4%; n=21) were excluded. Among the rhinitis population (n=113), the prevalence of NAR was 57% (n=46). The major presenting symptoms included nasal obstruction (93%; n=43), postnasal drainage (78%; n=36), and rhinorrhea (62%; n=29). For the knowledge gap study; 115 Medline titles were reviewed, four systematic reviews, and 34 research papers were reviewed. The text of two recent otolaryngology text books was also reviewed, and the main results of the study revealed the prevalence of NAR had not previously been studied in Oman. Although the recent text now clearly defines NAR, there is scant literature on the prevalence, diagnosis and management outcomes of NAR in the literature. CONCLUSION The study found that more than half of rhinitis patients suffered from NAR. There are no specific diagnostic tests for NAR; a thorough case history is the best diagnostic tool to date. A substantial knowledge gap exists in literature with relations to pathogenesis, clinical and laboratory diagnosis, as well as in reference to medical and surgical outcomes. Larger studies are required and management outcomes need to be studied.
Collapse
|
8
|
Han YY, Lee YL, Guo YL. Indoor environmental risk factors and seasonal variation of childhood asthma. Pediatr Allergy Immunol 2009; 20:748-56. [PMID: 19236600 DOI: 10.1111/j.1399-3038.2009.00871.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Seasonality of asthma may result from varying exposures. This cross-sectional study was designed to examine the relationship between indoor environmental factors and seasonal childhood asthma. Study subjects were participants from the International Study of Asthma and Allergies in Childhood (ISAAC) in 2004, a population-based surveillance, which included school children aged 6-15 yr in south Taiwan. Cases included 1725 children who experienced asthma symptoms in the past 12 months and the references consisted of 19,646 children who reportedly have no asthma history. By using a moving average and principal component analysis, asthmatic children were grouped into four asthma subtypes: winter, spring, summer/fall, and perennial. Multivariate logistic regression was used to evaluate the effect of indoor environmental factors on seasonality of childhood asthma. For all asthma prevalence, a peak occurred in the winter and a nadir appeared in summer. Contributing factors of asthma for children, regardless of seasonality, included younger age, parental atopy, maternal smoking during pregnancy, breast feeding, and perceived air pollution. After adjusted for salient risk factors, water damage was significantly associated with all subtypes of asthma. Presence of cockroaches was related to the summer/fall asthma (adjusted odds ratio [aOR] = 1.65, 95% confidence interval [CI] = 1.12-2.55). Visible mold on the walls was associated with an increased occurrence of winter and spring asthma (aOR = 1.53, 95% CI = 1.26-1.85 and aOR = 1.34, 95% CI = 1.10-1.62, respectively). Passive smoking was shown to be related to spring and summer/fall asthma. Water damage is a possible risk for childhood asthma year-round. Cockroaches and visible mold on the walls may play essential roles for seasonality of childhood asthma in Taiwan. Plausible mechanisms and allergic effects should be further determined. Elimination of these allergens is necessary to help prevent the development of asthma.
Collapse
Affiliation(s)
- Yueh-Ying Han
- Department of Environmental and Occupational Medicine, National Taiwan University College of Medicine, Taipei, Taiwan
| | | | | |
Collapse
|
9
|
Bakke JV, Wieslander G, Norbäck D, Moen BE. Atopy, symptoms and indoor environmental perceptions, tear film stability, nasal patency and lavage biomarkers in university staff. Int Arch Occup Environ Health 2007; 81:861-72. [PMID: 18066577 DOI: 10.1007/s00420-007-0280-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Accepted: 11/14/2007] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Study associations between airway symptoms, complaints on environmental perceptions, atopy definitions and biomarkers including tear film stability (BUT), nasal patency and nasal lavage (NAL). Personal predictors (gender, age, smoking, infections) for the biomarkers as well as associations between the biomarkers were also assessed. METHODS A cross-sectional study of 173 employees in four university buildings, response rate 86%. Tear film break up time (BUT) was measured by a non-invasive method (NIBUT) and self-reported (SBUT). NAL-analysis included eosinophilic cationic protein (ECP), myeloperoxidase (MPO), lysozyme and albumin. Total serum IgE, and specific IgE using Phadiatop was measured. Data on subjective symptoms, environmental perceptions and background data were collected by use of a questionnaire. Multiple regression analyses were applied. RESULTS Mean age was 43 years, 21% had weekly ocular, 21% nasal, and 17% laryngeal symptoms. Women had more complaints on environmental perceptions, shorter BUT and less nasal patency. Neither atopy (Phadiatop) nor Total IgE or allergy in the family, but asthma and hay fever was associated with mucosal symptoms or perceptions. Subjects with positive Phadiatop had higher levels of all NAL-biomarkers. Those with ocular symptoms had shorter BUT. Nasal symptoms were related to respiratory infections and laryngeal symptoms to NAL-lysozyme. Perceiving dry air was associated with lower BUT and reduced nasal volume difference before and after decongestion. Older subjects had greater nasal patency, and less atopy. All NAL-biomarkers were positively correlated. Higher lysozyme level was associated with less nasal patency and greater nasal decongestion. CONCLUSIONS BUT and NAL-lysozyme was associated with ocular, nasal, laryngeal symptoms and indoor environmental perceptions. Ever having had asthma and ever having had hay fever were predictors for symptoms and perceived air quality, respectively. Phadiatop, Total IgE, familiar allergy and ever eczema were not associated to symptoms or perceived environments. Age, gender and Phadiatop were main predictors for ocular and nasal biomarkers.
Collapse
Affiliation(s)
- Jan Vilhelm Bakke
- Section for Occupational Medicine, Department of Public Health and Primary Health Care, University of Bergen, Kalfarveien 31, 5018 Bergen, Norway.
| | | | | | | |
Collapse
|
10
|
Cain WS, Jalowayski AA, Schmidt R, Kleinman M, Magruder K, Lee KC, Culver BD. Chemesthetic responses to airborne mineral dusts: boric acid compared to alkaline materials. Int Arch Occup Environ Health 2007; 81:337-45. [PMID: 17609973 DOI: 10.1007/s00420-007-0218-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2005] [Accepted: 06/06/2007] [Indexed: 11/25/2022]
Abstract
OBJECTIVES (1) To assess the relation between occupationally relevant exposures to dust of boric acid and magnitude of feel in the eye, nose, and throat during activity (pedaling) equal to light industrial work. (2) To compare feel from the dust of boric acid with that of the alkaline dusts calcium oxide and sodium tetraborate pentahydrate (sodium borate). (3) To chart how magnitude of feel changes with time in exposures up to 3/4 h. METHODS Twelve subjects, six males and six females, participated in duplicate sessions of exposure to 2.5, 5, and 10 mg m(-3) of boric acid, 10 mg m(-3) of sodium borate, 2.5 mg m(-3) of calcium oxide presented as calcium oxide alone or diluted with hydrated calcium sulfate, and 0 mg m(-3) (blank). Exposures occurred in a plastic dome suspended over the head and closed around the neck with rubber dam. Measurements pre- and post-exposure included nasal secretion and nasal resistance. Measurements during exposure included rated magnitude of feel in the eye, nose, and throat, and respiration (Respitrace System). Six concentrations of carbon dioxide ranging from just below detectable to sharply stinging gave subjects references for their ratings. RESULTS In general, feel increased for periods up to half an hour, then either declined or held at a plateau. Each material had a temporal signature. The nose led with the highest feel, followed by the throat, then the eyes. This hierarchy proved weakest for boric acid; at one level of exposure, magnitude in the throat overtook that in the nose. Accompanying measures implied that change of feel with time occurred neither because of an increase in dilution of the dissolved dusts in newly secreted mucus nor an increase of consequence in nasal resistance. Most likely, sensory adaptation determined the change. Boric acid of 10 mg m(-3) fell slightly and insignificantly below 10 mg m(-3) sodium borate in feel. Boric acid, though, showed a relatively flat dose-response relationship, i.e., a change in level caused little change in feel. CONCLUSIONS The time-constant for feel from dusts lies on the order of tens of minutes. A flat concentration-response function for boric acid and a notable response from the throat suggests that perceived dryness, not mediated by acidity but perhaps by osmotic pressure, may account for the feel evoked at levels of exposure at or below 10 mg m(-3). More acidic dusts that could actually change nasal pH may trigger sensations differently.
Collapse
Affiliation(s)
- William S Cain
- Chemosensory Perception Laboratory, Department of Surgery (Otolaryngology), University of California, San Diego, La Jolla, CA 92093-0957, USA.
| | | | | | | | | | | | | |
Collapse
|