1
|
Cho E, Wu JKY, Birriel DC, Matelski J, Nadj R, DeHaas E, Huang Q, Yang K, Xu T, Cheung AB, Woo LN, Day L, Cypel M, Tikkanen J, Ryan C, Chow CW. Airway Oscillometry Detects Spirometric-Silent Episodes of Acute Cellular Rejection. Am J Respir Crit Care Med 2020; 201:1536-1544. [PMID: 32135068 DOI: 10.1164/rccm.201908-1539oc] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Rationale: Acute cellular rejection (ACR) is common during the initial 3 months after lung transplant. Patients are monitored with spirometry and routine surveillance transbronchial biopsies. However, many centers monitor patients with spirometry only because of the risks and insensitivity of transbronchial biopsy for detecting ACR. Airway oscillometry is a lung function test that detects peripheral airway inhomogeneity with greater sensitivity than spirometry. Little is known about the role of oscillometry in patient monitoring after a transplant.Objectives: To characterize oscillometry measurements in biopsy-proven clinically significant (grade ≥2 ACR) in the first 3 months after a transplant.Methods: We enrolled 156 of the 209 double lung transplant recipients between December 2017 and March 2019. Weekly outpatient oscillometry and spirometry and surveillance biopsies at Weeks 6 and 12 were conducted at our center.Measurements and Main Results: Of the 138 patients followed for 3 or more months, 15 patients had 16 episodes of grade 2 ACR (AR2) and 44 patients had 64 episodes of grade 0 ACR (AR0) rejection associated with stable and/or improving spirometry. In 15/16 episodes of AR2, spirometry was stable or improving in the weeks leading to transbronchial biopsy. However, oscillometry was markedly abnormal and significantly different from AR0 (P < 0.05), particularly in integrated area of reactance and the resistance between 5 and 19 Hz, the indices of peripheral airway obstruction. By 2 weeks after biopsy, after treatment for AR2, oscillometry in the AR2 group improved and was similar to the AR0 group.Conclusions: Oscillometry identified physiological changes associated with AR2 that were not discernible by spirometry and is useful for graft monitoring after a lung transplant.
Collapse
Affiliation(s)
- Elizabeth Cho
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Joyce K Y Wu
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Pulmonary Function Laboratory
| | - Daniella Cunha Birriel
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Toronto Lung Transplant Programme, Multi-Organ Transplant Unit
| | | | - Richard Nadj
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Emily DeHaas
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Qian Huang
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Kelsey Yang
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Tong Xu
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Aloysius B Cheung
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Lindsay N Woo
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Lauren Day
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Pulmonary Function Laboratory
| | - Marcelo Cypel
- Toronto Lung Transplant Programme, Multi-Organ Transplant Unit.,Division of Thoracic Surgery, Department of Surgery, University Health Network, Toronto, Ontario, Canada
| | - Jussi Tikkanen
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Toronto Lung Transplant Programme, Multi-Organ Transplant Unit
| | - Clodagh Ryan
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Pulmonary Function Laboratory
| | - Chung-Wai Chow
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Toronto Lung Transplant Programme, Multi-Organ Transplant Unit
| |
Collapse
|
2
|
Zannin E, Ventura ML, Dognini G, Veneroni C, Pillow JJ, Tagliabue PE, Dellacà RL. Regional distribution of chest wall displacements in infants during high-frequency ventilation. J Appl Physiol (1985) 2019; 126:928-933. [PMID: 30730808 DOI: 10.1152/japplphysiol.01086.2018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The distribution of ventilation during high-frequency ventilation (HFV) is asynchronous, nonhomogeneous, and frequency dependent. We hypothesized that differences in the regional distribution of ventilation at different oscillatory frequencies may affect gas exchange efficiency. We studied 15 newborn infants with a median gestational age of 28.9 (26.4-30.3) wk and body weight of 1.0 (0.8-1.4) kg. Five ventilation frequencies (5, 8, 10, 12, and 15 Hz) were tested, keeping carbon dioxide diffusion coefficient constant. The displacements of 24 passive markers placed on the infant's chest wall were measured by optoelectronic plethysmography. We evaluated the amplitude and phase shift of displacements of single markers placed along the midline and the regional displacements of the chest wall surface. Blood gases were unaffected by frequency. Chest wall volume changes decreased from 1.6 (0.4) ml/kg at 5 Hz to 0.7 ml/kg at 15 Hz. At all frequencies, the abdomen (AB) oscillated more markedly than the ribcage (RC). The mean (SD) AB/RC ratio was 1. 95 (0.7) at 5 Hz, increased to 2.1 (1.3) at 10 Hz, and then decreased to 1.1 (0.5) at 15 Hz ( P < 0.05 vs. 10 Hz). Volume changes in the AB lagged the RC and this phase shift increased with frequency. The AB oscillated more than the RC at all frequencies. Regional oscillations were highly inhomogeneous up to 10 Hz, and they became progressively more asynchronous with increasing frequency. When the carbon dioxide diffusion coefficient is held constant, such differences in regional chest wall expansion do not affect gas exchange. NEW & NOTEWORTHY We characterized the regional distribution of chest wall displacements in infants receiving high-frequency oscillatory ventilation at different frequencies. When carbon dioxide diffusion coefficient is held constant, there is no combination of frequency and tidal volume that optimizes gas exchange. The relative displacement between different chest wall compartments is not affected by frequency. However, at high frequencies, chest wall displacements are lower, with the potential to reduce total and regional overdistension without affecting gas exchange.
Collapse
Affiliation(s)
- Emanuela Zannin
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano University , Milan , Italy
| | | | - Giulia Dognini
- Neonatal Intensive Care Unit, Fondazione MBBM-ASST-Monza, Monza, Italy
| | - Chiara Veneroni
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano University , Milan , Italy
| | - Jane J Pillow
- Centre for Neonatal Research and Education, University of Western Australia , Perth , Australia.,School of Human Sciences, University of Western Australia , Perth , Australia
| | - Paolo E Tagliabue
- Neonatal Intensive Care Unit, Fondazione MBBM-ASST-Monza, Monza, Italy
| | - Raffaele L Dellacà
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano University , Milan , Italy
| |
Collapse
|
3
|
Chest Wall Kinematics Using Triangular Cosserat Point Elements in Healthy and Neuromuscular Subjects. Ann Biomed Eng 2017; 45:1963-1973. [PMID: 28451990 DOI: 10.1007/s10439-017-1840-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Accepted: 04/21/2017] [Indexed: 10/19/2022]
Abstract
Optoelectronic plethysmography (OEP) is a noninvasive method for assessing lung volume variations and the contributions of different anatomical compartments of the chest wall (CW) through measurements of the motion of markers attached to the CW surface. The present study proposes a new method for analyzing the local CW kinematics from OEP measurements based on the kinematics of triangular Cosserat point elements (TCPEs). 52 reflective markers were placed on the anterior CW to create a mesh of 78 triangles according to an anatomical model. Each triangle was characterized by a TCPE and its kinematics was described using four time-variant scalar TCPE parameters. The total CW volume ([Formula: see text]) and the contributions of its six compartments were also estimated, using the same markers. The method was evaluated using measurements of ten healthy subjects, nine patients with Pompe disease, and ten patients with Duchenne muscular dystrophy (DMD), during spontaneous breathing (SB) and vital capacity maneuvers (VC) in the supine position. TCPE parameters and compartmental volumes were compared with [Formula: see text] by computing the phase angles [Formula: see text] (for SB) and the correlation r (for VC) between them. Analysis of [Formula: see text] and r of the outward translation parameter [Formula: see text] of each TCPE revealed that for healthy subjects it provided similar results to those obtained by compartmental volumes, whereas for the neuromuscular patients the TCPE method was capable of detecting local asynchronous and paradoxical movements also in cases where they were undistinguished by volumes. Therefore, the TCPE approach provides additional information to OEP that may enhance its clinical evaluation capabilities.
Collapse
|
4
|
Sohn K, Warwick WJ, Lee YW, Lee J, Holte JE. Investigation of non-uniform airflow signal oscillation during high frequency chest compression. Biomed Eng Online 2005; 4:34. [PMID: 15904523 PMCID: PMC1173124 DOI: 10.1186/1475-925x-4-34] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2005] [Accepted: 05/19/2005] [Indexed: 11/17/2022] Open
Abstract
Background High frequency chest compression (HFCC) is a useful and popular therapy for clearing bronchial airways of excessive or thicker mucus. Our observation of respiratory airflow of a subject during use of HFCC showed the airflow oscillation by HFCC was strongly influenced by the nonlinearity of the respiratory system. We used a computational model-based approach to analyse the respiratory airflow during use of HFCC. Methods The computational model, which is based on previous physiological studies and represented by an electrical circuit analogue, was used for simulation of in vivo protocol that shows the nonlinearity of the respiratory system. Besides, airflow was measured during use of HFCC. We compared the simulation results to either the measured data or the previous research, to understand and explain the observations. Results and discussion We could observe two important phenomena during respiration pertaining to the airflow signal oscillation generated by HFCC. The amplitudes of HFCC airflow signals varied depending on spontaneous airflow signals. We used the simulation results to investigate how the nonlinearity of airway resistance, lung capacitance, and inertance of air characterized the respiratory airflow. The simulation results indicated that lung capacitance or the inertance of air is also not a factor in the non-uniformity of HFCC airflow signals. Although not perfect, our circuit analogue model allows us to effectively simulate the nonlinear characteristics of the respiratory system. Conclusion We found that the amplitudes of HFCC airflow signals behave as a function of spontaneous airflow signals. This is due to the nonlinearity of the respiratory system, particularly variations in airway resistance.
Collapse
Affiliation(s)
- Kiwon Sohn
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Warren J Warwick
- Department of Pediatrics, University of Minnesota, Minneapolis, MN, USA
| | - Yong W Lee
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Jongwon Lee
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - James E Holte
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
5
|
Dellacà RL, Black LD, Atileh H, Pedotti A, Lutchen KR. Effects of posture and bronchoconstriction on low-frequency input and transfer impedances in humans. J Appl Physiol (1985) 2004; 97:109-18. [PMID: 14966017 DOI: 10.1152/japplphysiol.00721.2003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
We simultaneously evaluated the mechanical response of the total respiratory system, lung, and chest wall to changes in posture and to bronchoconstriction. We synthesized the optimal ventilation waveform (OVW) approach, which simultaneously provides ventilation and multifrequency forcing, with optoelectronic plethysmography (OEP) to measure chest wall flow globally and locally. We applied an OVW containing six frequencies from 0.156 to 4.6 Hz to the mouth of six healthy men in the seated and supine positions, before and after methacholine challenge. We measured mouth, esophageal, and transpulmonary pressures, airway flow by pneumotachometry, and total chest wall, pulmonary rib cage, and abdominal volumes by OEP. We computed total respiratory, lung, and chest wall input impedances and the total and regional transfer impedances (Ztr). These data were appropriately sensitive to changes in posture, showing added resistance in supine vs. seated position. The Ztr were also highly sensitive to lung constriction, more so than input impedance, as the former is minimally distorted by shunting of flow into alveolar gas compression and airway walls. Local impedances show that, during bronchoconstriction and at typical breathing frequencies, the contribution of the abdomen becomes amplified relative to the rib cage. A similar redistribution occurs when passing from seated to supine. These data suggest that the OEP-OVW approach for measuring Ztr could noninvasively track important lung and respiratory conditions, even in subjects who cannot cooperate. Applications might range from routine evaluation of airway hyperreactivity in asthmatic subjects to critical conditions in the supine position during mechanical ventilation.
Collapse
Affiliation(s)
- Raffaele L Dellacà
- Dipartimento di Bioingegneria, Politecnico di Milano, I-20133 Milano, Italy.
| | | | | | | | | |
Collapse
|