1
|
Walsh T, Macey R, Kerr AR, Lingen MW, Ogden GR, Warnakulasuriya S. Diagnostic tests for oral cancer and potentially malignant disorders in patients presenting with clinically evident lesions. Cochrane Database Syst Rev 2021; 7:CD010276. [PMID: 34282854 PMCID: PMC8407012 DOI: 10.1002/14651858.cd010276.pub3] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Squamous cell carcinoma is the most common form of malignancy of the oral cavity, and is often proceeded by oral potentially malignant disorders (OPMD). Early detection of oral cavity squamous cell carcinoma (oral cancer) can improve survival rates. The current diagnostic standard of surgical biopsy with histology is painful for patients and involves a delay in order to process the tissue and render a histological diagnosis; other diagnostic tests are available that are less invasive and some are able to provide immediate results. This is an update of a Cochrane Review first published in 2015. OBJECTIVES Primary objective: to estimate the diagnostic accuracy of index tests for the detection of oral cancer and OPMD, in people presenting with clinically evident suspicious and innocuous lesions. SECONDARY OBJECTIVE to estimate the relative accuracy of the different index tests. SEARCH METHODS Cochrane Oral Health's Information Specialist searched the following databases: MEDLINE Ovid (1946 to 20 October 2020), and Embase Ovid (1980 to 20 October 2020). The US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were also searched for ongoing trials to 20 October 2020. No restrictions were placed on the language or date of publication when searching the electronic databases. We conducted citation searches, and screened reference lists of included studies for additional references. SELECTION CRITERIA We selected studies that reported the diagnostic test accuracy of the following index tests when used as an adjunct to conventional oral examination in detecting OPMD or oral cavity squamous cell carcinoma: vital staining (a dye to stain oral mucosa tissues), oral cytology, light-based detection and oral spectroscopy, blood or saliva analysis (which test for the presence of biomarkers in blood or saliva). DATA COLLECTION AND ANALYSIS Two review authors independently screened titles and abstracts for relevance. Eligibility, data extraction and quality assessment were carried out by at least two authors, independently and in duplicate. Studies were assessed for methodological quality using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Meta-analysis was used to combine the results of studies for each index test using the bivariate approach to estimate the expected values of sensitivity and specificity. MAIN RESULTS This update included 63 studies (79 datasets) published between 1980 and 2020 evaluating 7942 lesions for the quantitative meta-analysis. These studies evaluated the diagnostic accuracy of conventional oral examination with: vital staining (22 datasets), oral cytology (24 datasets), light-based detection or oral spectroscopy (24 datasets). Nine datasets assessed two combined index tests. There were no eligible diagnostic accuracy studies evaluating blood or salivary sample analysis. Two studies were classed as being at low risk of bias across all domains, and 33 studies were at low concern for applicability across the three domains, where patient selection, the index test, and the reference standard used were generalisable across the population attending secondary care. The summary estimates obtained from the meta-analysis were: - vital staining: sensitivity 0.86 (95% confidence interval (CI) 0.79 to 0.90) specificity 0.68 (95% CI 0.58 to 0.77), 20 studies, sensitivity low-certainty evidence, specificity very low-certainty evidence; - oral cytology: sensitivity 0.90 (95% CI 0.82 to 0.94) specificity 0.94 (95% CI 0.88 to 0.97), 20 studies, sensitivity moderate-certainty evidence, specificity moderate-certainty evidence; - light-based: sensitivity 0.87 (95% CI 0.78 to 0.93) specificity 0.50 (95% CI 0.32 to 0.68), 23 studies, sensitivity low-certainty evidence, specificity very low-certainty evidence; and - combined tests: sensitivity 0.78 (95% CI 0.45 to 0.94) specificity 0.71 (95% CI 0.53 to 0.84), 9 studies, sensitivity very low-certainty evidence, specificity very low-certainty evidence. AUTHORS' CONCLUSIONS At present none of the adjunctive tests can be recommended as a replacement for the currently used standard of a surgical biopsy and histological assessment. Given the relatively high values of the summary estimates of sensitivity and specificity for oral cytology, this would appear to offer the most potential. Combined adjunctive tests involving cytology warrant further investigation. Potentially eligible studies of blood and salivary biomarkers were excluded from the review as they were of a case-control design and therefore ineligible. In the absence of substantial improvement in the tests evaluated in this updated review, further research into biomarkers may be warranted.
Collapse
Affiliation(s)
- Tanya Walsh
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Richard Macey
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Alexander R Kerr
- Department of Oral and Maxillofacial Pathology, Radiology and Medicine, New York University College of Dentistry, New York, USA
| | - Mark W Lingen
- Pritzker School of Medicine, Division of Biological Sciences, Department of Pathology, University of Chicago, Chicago, Illinois, USA
| | - Graham R Ogden
- Division of Oral and Maxillofacial Clinical Sciences, School of Dentistry, University of Dundee, Dundee, UK
| | | |
Collapse
|
2
|
Voulgarelis S, Fathi F, Stucke AG, Daley KD, Kim J, Zimmerman MA, Hong JC, Starkey N, Allen KP, Yu B. Evaluation of visible diffuse reflectance spectroscopy in liver tissue: validation of tissue saturations using extracorporeal circulation. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210019R. [PMID: 34021537 PMCID: PMC8145982 DOI: 10.1117/1.jbo.26.5.055002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/03/2021] [Indexed: 05/13/2023]
Abstract
SIGNIFICANCE Real-time information about oxygen delivery to the hepatic graft is important to direct care and diagnose vascular compromise in the immediate post-transplant period. AIM The current study was designed to determine the utility of visible diffuse reflectance spectroscopy (vis-DRS) for measuring liver tissue saturation in vivo. APPROACH A custom-built vis-DRS probe was calibrated using phantoms with hemoglobin (Hb) and polystyrene microspheres. Ex vivo (extracorporeal circulation) and in vivo protocols were used in a swine model (n = 15) with validation via blood gas analysis. RESULTS In vivo absorption and scattering measured by vis-DRS with and without biliverdin correction correlated closely between analyses. Lin's concordance correlation coefficients are 0.991 for μa and 0.959 for μs ' . Hb measured by blood test and vis-DRS with (R2 = 0.81) and without (R2 = 0.85) biliverdin correction were compared. Vis-DRS data obtained from the ex vivo protocol plotted against the PO2 derived from blood gas analysis showed a good fit for a Hill coefficient of 1.67 and P50 = 34 mmHg (R2 = 0.81). A conversion formula was developed to account for the systematic deviation, which resulted in a goodness-of-fit R2 = 0.76 with the expected oxygen dissociation curve. CONCLUSIONS We show that vis-DRS allows for real-time measurement of liver tissue saturation, an indicator for liver perfusion and oxygen delivery.
Collapse
Affiliation(s)
- Stylianos Voulgarelis
- Medical College of Wisconsin, Children’s Wisconsin, Department of Anesthesiology, Milwaukee, Wisconsin, United States
- Address all correspondence to Stylianos Voulgarelis,
| | - Faraneh Fathi
- Marquette University and Medical College of Wisconsin, Department of Biomedical Engineering, Milwaukee, Wisconsin, United States
| | - Astrid G. Stucke
- Medical College of Wisconsin, Children’s Wisconsin, Department of Anesthesiology, Milwaukee, Wisconsin, United States
| | - Kevin D. Daley
- Herma Heart Institute, Children’s Wisconsin, Department of Perfusion, Milwaukee, Wisconsin, United States
| | - Joohyun Kim
- Medical College of Wisconsin, Children’s Hospital of Wisconsin, Department of Surgery, Division of Transplant Surgery, Milwaukee, Wisconsin, United States
| | - Michael A. Zimmerman
- Medical College of Wisconsin, Children’s Hospital of Wisconsin, Department of Surgery, Division of Transplant Surgery, Milwaukee, Wisconsin, United States
| | - Johnny C. Hong
- Medical College of Wisconsin, Children’s Hospital of Wisconsin, Department of Surgery, Division of Transplant Surgery, Milwaukee, Wisconsin, United States
| | - Nicholas Starkey
- Herma Heart Institute, Children’s Wisconsin, Department of Perfusion, Milwaukee, Wisconsin, United States
| | - Kenneth P. Allen
- Biomedical Resource Center, Medical College of Wisconsin, Department of Immunology Microbiology, Milwaukee, Wisconsin, United States
| | - Bing Yu
- Marquette University and Medical College of Wisconsin, Department of Biomedical Engineering, Milwaukee, Wisconsin, United States
| |
Collapse
|
3
|
A Sensitive Fibre Optic Probe for Autofluorescence Spectroscopy of Oral Tongue Cancer: Monte Carlo Simulation Study. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1936570. [PMID: 32337228 PMCID: PMC7168752 DOI: 10.1155/2020/1936570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/11/2020] [Accepted: 03/25/2020] [Indexed: 11/17/2022]
Abstract
The objective of this paper is to determine the best optical probe configuration that would help to detect neoplastic lesions in oral tongue epithelial tissue. Three geometrical configurations are investigated. The first one is a single-fibre probe with different fibre diameters. The second one is a multitilted fibre probe that employs different tilting angles for emission and collection fibres. While the third one is a multidiameter probe that employs different fibre diameters and distances between the emission and the collection fibres. All probes were evaluated for their depth-limited sensitivity in the epithelium layer of the tongue. Probes that showed efficient sensitivities were then compared for their fluorescence intensities acquired from both tissue types. The sensitivity for the first two types of probes was found to be roughly comparable. However, the differentiation capability of the multitilted fibre probe between dysplastic and healthy tissue was found to be noticeably larger by 30% of that of the single-fibre probe. The third type showed more sensitivity to fluorescence emerging from deeper layers. Finally, the proposed configuration is presented and proved to achieve higher sensitivity for both superficial and deep layers.
Collapse
|
4
|
Ye Y, Tan Y, Jin G. Accurate measurement for damage evolution of ceramics caused by nanosecond laser pulses with polarization spectrum imaging. OPTICS EXPRESS 2019; 27:16360-16376. [PMID: 31163814 DOI: 10.1364/oe.27.016360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 05/14/2019] [Indexed: 06/09/2023]
Abstract
Due to the interference of excitation lights and the perturbation of spattered particles, it is very difficult to detect the real-time evolution of ceramics damaged by pulsed laser. In this paper, a metrology "on-line detection of damage identification via the polarization spectrum imaging" is proposed to realize the real-time observation for damage evolution of ceramic composite irradiated by the laser. In this metrology, the detection principle is based on a mathematical model of polarization bidirectional reflectance distribution function. According to the Stokes vector analysis method, the damage law of the material surface under the continuous activating illuminations of multiple laser pulses and the increase of pulse energy is theoretically deduced and analyzed first, then the measured polarization spectra are compared with the microscopic imaging method to extract the edge texture information, and further the damage details are characterized with this metrology under the typical polarization parameters: I, Q, U, V, DOP and AOP. As a result, the damaging degree of ceramic composite irradiated by the 1064nm nanosecond pulsed laser, which is changed from the pulse power of 155.54 mJ and 14 pulses to 217.94 mJ and 1 pulse, can be identified with a series of polarization parameters in the different polarization spectrum images. These polarization parameters and their derived results reflect the physical and chemical evolutive properties including of texture orientation of the target surface that is different from other methods of damage detection. Finally, it can be concluded that this paper provides a new method for real-time detection of laser damage and lays a foundation for detection and identification under other strong light interference.
Collapse
|
5
|
Qi J, Elson DS. Mueller polarimetric imaging for surgical and diagnostic applications: a review. JOURNAL OF BIOPHOTONICS 2017; 10:950-982. [PMID: 28464464 DOI: 10.1002/jbio.201600152] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Revised: 01/18/2017] [Accepted: 01/19/2017] [Indexed: 05/02/2023]
Abstract
Polarization is a fundamental property of light and a powerful sensing tool that has been applied to many areas. A Mueller matrix is a complete mathematical description of the polarization characteristics of objects that interact with light, and is known as a transfer function of Stokes vectors which characterise the state of polarization of light. Mueller polarimetric imaging measures Mueller matrices over a field of view and thus allows for visualising the polarization characteristics of the objects. It has emerged as a promising technique in recent years for tissue imaging, improving image contrast and providing a unique perspective to reveal additional information that cannot be resolved by other optical imaging modalities. This review introduces the basis of the Stokes-Mueller formulism, interpretation methods of Mueller matrices into fundamental polarization properties, polarization properties of biological tissues, and considerations in the construction of Mueller polarimetric imaging devices for surgical and diagnostic applications, including primary configurations, optimization procedures, calibration methods as well as the instrument polarization properties of several widely-used biomedical optical devices. The paper also reviews recent progress in Mueller polarimetric endoscopes and fibre Mueller polarimeters, followed by the future outlook in applying the technique to surgery and diagnostics. Tissue polarization properties convey morphological, micro-structural and compositional information of tissue with great potential for label free characterization of tissue pathological changes. Recent progress in tissue polarimetric imaging and polarization resolved endoscopy paved the way for translation of polarimetric imaging to surgery and tissue diagnosis.
Collapse
Affiliation(s)
- Ji Qi
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| |
Collapse
|
6
|
Bailey MJ, Verma N, Fradkin L, Lam S, MacAulay C, Poh C, Markey MK, Sokolov K. Detection of precancerous lesions in the oral cavity using oblique polarized reflectance spectroscopy: a clinical feasibility study. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:65002. [PMID: 28609512 PMCID: PMC5469421 DOI: 10.1117/1.jbo.22.6.065002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 05/18/2017] [Indexed: 05/20/2023]
Abstract
We developed a multifiber optical probe for oblique polarized reflectance spectroscopy (OPRS) in vivo and evaluated its performance in detection of dysplasia in the oral cavity. The probe design allows the implementation of a number of methods to enable depth resolved spectroscopic measurements including polarization gating, source–detector separation, and differential spectroscopy; this combination was evaluated in carrying out binary classification tasks between four major diagnostic categories: normal, benign, mild dysplasia (MD), and severe dysplasia (SD). Multifiber OPRS showed excellent performance in the discrimination of normal from benign, MD, SD, and MD plus SD yielding sensitivity/specificity values of 100%/93%, 96%/95%, 100%/98%, and 100%/100%, respectively. The classification of benign versus dysplastic lesions was more challenging with sensitivity and specificity values of 80%/93%, 71%/93%, and 74%/80% in discriminating benign from SD, MD, and SD plus MD categories, respectively; this challenge is most likely associated with a strong and highly variable scattering from a keratin layer that was found in these sites. Classification based on multiple fibers was significantly better than that based on any single detection pair for tasks dealing with benign versus dysplastic sites. This result indicates that the multifiber probe can perform better in the detection of dysplasia in keratinized tissues.
Collapse
Affiliation(s)
- Maria J. Bailey
- University of Texas M.D. Anderson Cancer Center, Department of Imaging Physics, Houston, Texas, United States
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
| | - Nishant Verma
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
| | - Leonid Fradkin
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
| | - Sylvia Lam
- British Columbia Cancer Agency, Integrative Oncology Department, Vancouver, British Columbia, Canada
| | - Calum MacAulay
- British Columbia Cancer Agency, Integrative Oncology Department, Vancouver, British Columbia, Canada
| | - Catherine Poh
- British Columbia Cancer Agency, Integrative Oncology Department, Vancouver, British Columbia, Canada
| | - Mia K. Markey
- University of Texas M.D. Anderson Cancer Center, Department of Imaging Physics, Houston, Texas, United States
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
| | - Konstantin Sokolov
- University of Texas M.D. Anderson Cancer Center, Department of Imaging Physics, Houston, Texas, United States
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
- Rice University, Department of Bioengineering, Houston, Texas, United States
| |
Collapse
|
7
|
Bailey MJ, Sokolov K. Depth-resolved measurements with elliptically polarized reflectance spectroscopy. BIOMEDICAL OPTICS EXPRESS 2016; 7:2861-76. [PMID: 27446712 PMCID: PMC4948636 DOI: 10.1364/boe.7.002861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Revised: 06/09/2016] [Accepted: 06/15/2016] [Indexed: 05/11/2023]
Abstract
The ability of elliptical polarized reflectance spectroscopy (EPRS) to detect spectroscopic alterations in tissue mimicking phantoms and in biological tissue in situ is demonstrated. It is shown that there is a linear relationship between light penetration depth and ellipticity. This dependence is used to demonstrate the feasibility of a depth-resolved spectroscopic imaging using EPRS. The advantages and drawbacks of EPRS in evaluation of biological tissue are analyzed and discussed.
Collapse
Affiliation(s)
- Maria J. Bailey
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX 77030, USA
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, USA
| | - Konstantin Sokolov
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX 77030, USA
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, USA
- Department of Bioengineering, Rice University, Houston, TX 77005, USA
| |
Collapse
|
8
|
Nichols BS, Schindler CE, Brown JQ, Wilke LG, Mulvey CS, Krieger MS, Gallagher J, Geradts J, Greenup RA, Von Windheim JA, Ramanujam N. A Quantitative Diffuse Reflectance Imaging (QDRI) System for Comprehensive Surveillance of the Morphological Landscape in Breast Tumor Margins. PLoS One 2015; 10:e0127525. [PMID: 26076123 PMCID: PMC4468201 DOI: 10.1371/journal.pone.0127525] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Accepted: 04/16/2015] [Indexed: 11/18/2022] Open
Abstract
In an ongoing effort to address the clear clinical unmet needs surrounding breast conserving surgery (BCS), our group has developed a next-generation multiplexed optical-fiber-based tool to assess breast tumor margin status during initial surgeries. Specifically detailed in this work is the performance and clinical validation of a research-grade intra-operative tool for margin assessment based on diffuse optical spectroscopy. Previous work published by our group has illustrated the proof-of-concept generations of this device; here we incorporate a highly optimized quantitative diffuse reflectance imaging (QDRI) system utilizing a wide-field (imaging area = 17cm2) 49-channel multiplexed fiber optic probe, a custom raster-scanning imaging platform, a custom dual-channel white LED source, and an astronomy grade imaging CCD and spectrograph. The system signal to noise ratio (SNR) was found to be greater than 40dB for all channels. Optical property estimation error was found to be less than 10%, on average, over a wide range of absorption (μa = 0–8.9cm-1) and scattering (μs’ = 7.0–9.7cm-1) coefficients. Very low inter-channel and CCD crosstalk was observed (2% max) when used on turbid media (including breast tissue). A raster-scanning mechanism was developed to achieve sub-pixel resolution and was found to be optimally performed at an upsample factor of 8, affording 0.75mm spatially resolved diffuse reflectance images (λ = 450–600nm) of an entire margin (area = 17cm2) in 13.8 minutes (1.23cm2/min). Moreover, controlled pressure application at the probe-tissue interface afforded by the imaging platform reduces repeated scan variability, providing <1% variation across repeated scans of clinical specimens. We demonstrate the clinical utility of this device through a pilot 20-patient study of high-resolution optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient. An empirical cumulative distribution function (eCDF) analysis is used to reduce optical property maps to quantitative distributions representing the morphological landscape of breast tumor margins. The optimizations presented in this work provide an avenue to rapidly survey large tissue areas on intra-operative time scales with improved sensitivity to regions of focal disease that may otherwise be overlooked.
Collapse
Affiliation(s)
- Brandon S. Nichols
- Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
- * E-mail:
| | - Christine E. Schindler
- Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
| | - Jonathon Q. Brown
- Zenalux Biomedical, Research Triangle Park, NC, United States of America
- Department of Biomedical Engineering, Tulane University, New Orleans, LA, United States of America
| | - Lee G. Wilke
- Department of Surgery, The University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, United States of America
| | - Christine S. Mulvey
- Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
| | - Marlee S. Krieger
- Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
- Zenalux Biomedical, Research Triangle Park, NC, United States of America
| | - Jennifer Gallagher
- Department of Surgery, Duke University Medical Center, Durham, NC, United States of America
| | - Joseph Geradts
- Department of Pathology, Duke University Medical Center, Durham, NC, United States of America
| | - Rachel A. Greenup
- Department of Surgery, Duke University Medical Center, Durham, NC, United States of America
| | - Jesko A. Von Windheim
- Zenalux Biomedical, Research Triangle Park, NC, United States of America
- The Division of Environmental Sciences and Policy, Duke University, Durham, NC, United States of America
| | - Nirmala Ramanujam
- Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
- Zenalux Biomedical, Research Triangle Park, NC, United States of America
| |
Collapse
|
9
|
Macey R, Walsh T, Brocklehurst P, Kerr AR, Liu JLY, Lingen MW, Ogden GR, Warnakulasuriya S, Scully C. Diagnostic tests for oral cancer and potentially malignant disorders in patients presenting with clinically evident lesions. Cochrane Database Syst Rev 2015; 2015:CD010276. [PMID: 26021841 PMCID: PMC7087440 DOI: 10.1002/14651858.cd010276.pub2] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Oral squamous cell carcinoma is the most common form of malignancy of the lip and oral cavity, often being proceeded by potentially malignant disorders (PMD). Early detection can reduce the malignant transformation of PMD and can improve the survival rate for oral cancer. The current standard of scalpel biopsy with histology is painful for patients and involves a delay whilst histology is completed; other tests are available that are unobtrusive and provide immediate results. OBJECTIVES PRIMARY OBJECTIVE To estimate the diagnostic accuracy of index tests for the detection of oral cancer and PMD of the lip and oral cavity, in people presenting with clinically evident lesions. SECONDARY OBJECTIVE To estimate the relative accuracy of the different index tests. SEARCH METHODS The electronic databases were searched on 30 April 2013. We searched MEDLINE (OVID) (1946 to April 2013) and four other electronic databases (the Cochrane Diagnostic Test Accuracy Studies Register, the Cochrane Oral Health Group's Trials Register, EMBASE (OVID) and MEDION (Ovid)). There were no restrictions on language in the searches of the electronic databases. We conducted citation searches and screened reference lists of included studies for additional references. SELECTION CRITERIA We selected studies that reported the diagnostic test accuracy of the following index tests when used as an adjunct to conventional oral examination in detecting PMD or oral squamous cell carcinoma of the lip or oral cavity: vital staining, oral cytology, light-based detection and oral spectroscopy, blood or saliva analysis (which test for the presence of biomarkers in blood or saliva). DATA COLLECTION AND ANALYSIS Two review authors independently screened titles and abstracts for relevance. Eligibility, data extraction and quality assessment were carried out by at least two authors, independently and in duplicate. Studies were assessed for methodological quality using QUADAS-2. Meta-analysis was used to combine the results of studies for each index test using the bivariate approach to estimate the expected values of sensitivity and specificity. MAIN RESULTS We included 41 studies, recruiting 4002 participants, in this review. These studies evaluated the diagnostic accuracy of conventional oral examination with: vital staining (14 studies), oral cytology (13 studies), light-based detection or oral spectroscopy (13 studies). Six studies assessed two combined index tests. There were no eligible diagnostic accuracy studies evaluating blood or salivary sample analysis.The summary estimates for vital staining obtained from the meta-analysis were sensitivity of 0.84 (95% CI 0.74 to 0.90) with specificity of 0.70 (0.59 to 0.79), with 14 studies were included in the meta-analysis. For cytology, sensitivity was 0.91 (0.81 to 0.96) and specificity was 0.91 (0.81 to 0.95) with 12 studies included in the meta-analysis. For light-based detection, sensitivity was 0.91 (0.77 to 0.97) and specificity was 0.58 (0.22 to 0.87) with 11 studies included in the meta-analysis. The relative test accuracy was assessed by adding covariates to the bivariate analysis, no difference in model fit was observed. AUTHORS' CONCLUSIONS The overall quality of the included studies was poor. None of the adjunctive tests can be recommended as a replacement for the currently used standard of a scalpel biopsy and histological assessment. Given the relatively high values of the summary estimates of sensitivity and specificity for cytology, this would appear to offer the most potential. Combined adjunctive tests involving cytology warrant further investigation.
Collapse
Affiliation(s)
- Richard Macey
- School of Dentistry, The University of ManchesterCoupland 3 BuildingOxford RoadManchesterUKM13 9PL
| | - Tanya Walsh
- School of Dentistry, The University of ManchesterCoupland 3 BuildingOxford RoadManchesterUKM13 9PL
| | - Paul Brocklehurst
- Bangor UniversityNWORTH CTUY Wern (Normal Site)Holyhead RoadBangorUKLL57 2PZ
| | - Alexander R Kerr
- New York University College of DentistryDepartment of Oral and Maxillofacial Pathology, Radiology and Medicine345 East 24th StreetSchwartz BuildingNew YorkUSA10010
| | - Joseph LY Liu
- Scottish Dental Clinical Effectiveness Programme, NHS Education for ScotlandUniversity of Dundee, Dental Health Services Research UnitFrankland Building, Small's WyndDundeeUKDD1 4HN
| | - Mark W Lingen
- University of ChicagoPritzker School of Medicine, Division of Biological Sciences, Department of Pathology5841 South Maryland AvenueChicagoIllinoisUSA60637‐1470
| | - Graham R Ogden
- University of DundeeDivision of Oral and Maxillofacial Clinical Sciences, School of DentistryPark PlaceDundeeScotlandUKDD1 4HR
| | - Saman Warnakulasuriya
- King's College LondonClinical and Diagnostic SciencesBessemer RoadDenmark Hill CampusLondonUKSE5 9RW
| | - Crispian Scully
- University College London256 Gray's Inn RoadLondonUKWC1X 8LD
| | | |
Collapse
|
10
|
Krishna H, Majumder SK, Chaturvedi P, Sidramesh M, Gupta PK. In vivo Raman spectroscopy for detection of oral neoplasia: a pilot clinical study. JOURNAL OF BIOPHOTONICS 2014; 7:690-702. [PMID: 23821433 DOI: 10.1002/jbio.201300030] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 06/10/2013] [Accepted: 06/11/2013] [Indexed: 05/08/2023]
Abstract
We report a pilot study carried out to evaluate the applicability of in vivo Raman spectroscopy for differential diagnosis of malignant and potentially malignant lesions of human oral cavity in a clinical setting. The study involved 28 healthy volunteers and 171 patients having various lesions of oral cavity. The Raman spectra, measured from multiple sites of normal oral mucosa and of lesions belonging to three histopathological categories, viz. oral squamous cell carcinoma (OSCC), oral submucous fibrosis (OSMF) and leukoplakia (OLK), were subjected to a probability based multivariate statistical algorithm capable of direct multi-class classification. With respect to histology as the gold standard, the diagnostic algorithm was found to provide an accuracy of 85%, 89%, 85% and 82% in classifying the oral tissue spectra into the four tissue categories based on leave-one-subject-out cross validation. When employed for binary classification, the algorithm resulted in a sensitivity and specificity of 94% in discriminating normal from the rest of the abnormal spectra of OSCC, OSMF and OLK tissue sites pooled together.
Collapse
Affiliation(s)
- Hemant Krishna
- Laser Biomedical Applications and Instrumentation Division, R & D Block-D, Raja Ramanna Centre for Advanced Technology, Indore-452013, India
| | | | | | | | | |
Collapse
|
11
|
Fuller C, Camilon R, Nguyen S, Jennings J, Day T, Gillespie MB. Adjunctive diagnostic techniques for oral lesions of unknown malignant potential: Systematic review with meta-analysis. Head Neck 2014; 37:755-62. [PMID: 24596227 DOI: 10.1002/hed.23667] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 02/12/2014] [Accepted: 03/01/2014] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND The purpose of this study was to critically review the published evidence concerning adjunctive diagnostic techniques in the diagnosis of oral lesions of unknown malignant potential. METHODS We conducted a systematic literature review with meta-analysis using PubMed to search for articles published from June 1993 through June 2013 to identify prospective studies evaluating any diagnostic method, with tissue biopsy confirmation, in clinically evident oral lesions of unknown malignant potential. Aggregate weighted totals and SEs for true, false-positive, false-negative, and inadequate results were calculated and compared among subgroups. RESULTS Forty-eight articles satisfying inclusion criteria were identified. Twenty-five were included in quantitative synthesis. CONCLUSION Oral cytology holds higher diagnostic value than specialist's oral examination, which holds higher value than in vivo toluidine blue staining. This study does not support the use of computer-aided or liquid-based cytology. Future studies should be designed to test multiple methods in the same patient population to allow direct comparison among various techniques.
Collapse
Affiliation(s)
- Colin Fuller
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | | | | | | | | |
Collapse
|
12
|
Gomes AJ, Backman V. Algorithm for automated selection of application-specific fiber-optic reflectance probes. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:27012. [PMID: 23455876 PMCID: PMC3585420 DOI: 10.1117/1.jbo.18.2.027012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Revised: 01/11/2013] [Accepted: 01/15/2013] [Indexed: 05/19/2023]
Abstract
Several optical techniques and fiber-optic probe systems have been designed to measure the optical properties of tissue. While a wide range of options is often beneficial, it poses a problem to investigators selecting which method to use for their biomedical application of interest. We present a methodology to optimally select a probe that matches the application requirements. Our method is based both on matching a probe's mean sampling depth with the optimal diagnostic depth of the clinical application and on choosing a probe whose interrogation depth and path length is the least sensitive to alterations in the target medium's optical properties. Satisfying these requirements ensures that the selected probe consistently assesses the relevant tissue volume with minimum variability. To aid in probe selection, we have developed a publicly available graphical user interface that takes the desired sampling depth and optical properties of the medium as its inputs and automatically ranks different techniques in their ability to robustly target the desired depth. Techniques investigated include single fiber spectroscopy, differential path length spectroscopy, polarization-gating, elastic light scattering spectroscopy, and diffuse reflectance. The software has been applied to biological case studies.
Collapse
Affiliation(s)
- Andrew J. Gomes
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60218
| | - Vadim Backman
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60218
- Address all correspondence to: Vadim Backman, Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60218. Tel: (847) 491-3536; Fax: (847) 491-4928; E-mail:
| |
Collapse
|
13
|
Gomes AJ, Backman V. Analytical light reflectance models for overlapping illumination and collection area geometries. APPLIED OPTICS 2012. [PMID: 23207312 PMCID: PMC3655705 DOI: 10.1364/ao.51.008013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Several biomedical applications, such as detection of dysplasia, require selective interrogation of superficial tissue structures less than a few hundred micrometers thick. Techniques and methods have been developed to limit the penetration depth of light in tissue, including the design of systems such as fiber-optic probes that have overlapping illumination and collection areas on the tissue surface. For such geometries, the diffusion approximation to the light-transport equation typically does not apply, and as a result there is no general model to extract tissue optical properties from reflectance measurements. In the current study, we employ Monte Carlo (MC) simulations to develop simple and compact analytical models for the light reflectance from these overlapping geometries. These models incorporate the size of the illumination and collection areas, the collection angle, the polarization of the incident light, and the optical properties of the sample. Moreover, these MC simulations use the Whittle-Matérn model to describe scattering from spatially continuous refractive index media such as tissue, which is more general than models based on the conventionally used Henyey-Greenstein model. We validated these models on tissue-simulating phantoms. The models developed herein will facilitate the extraction of optical properties and aid in the design of optical systems employing overlapping illumination and collection areas, including fiber-optic probes for in vivo tissue diagnosis.
Collapse
|
14
|
Gomes AJ, Turzhitsky V, Ruderman S, Backman V. Monte Carlo model of the penetration depth for polarization gating spectroscopy: influence of illumination-collection geometry and sample optical properties. APPLIED OPTICS 2012; 51:4627-37. [PMID: 22781238 PMCID: PMC3557942 DOI: 10.1364/ao.51.004627] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Polarization-gating has been widely used to probe superficial tissue structures, but the penetration depth properties of this method have not been completely elucidated. This study employs a polarization-sensitive Monte Carlo method to characterize the penetration depth statistics of polarization-gating. The analysis demonstrates that the penetration depth depends on both the illumination-collection geometry [illumination-collection area (R) and collection angle (θ(c))] and on the optical properties of the sample, which include the scattering coefficient (μ(s)), absorption coefficient (μ(a)), anisotropy factor (g), and the type of the phase function. We develop a mathematical expression relating the average penetration depth to the illumination-collection beam properties and optical properties of the medium. Finally, we quantify the sensitivity of the average penetration depth to changes in optical properties for different geometries of illumination and collection. The penetration depth model derived in this study can be applied to optimizing application-specific fiber-optic probes to target a sampling depth of interest with minimal sensitivity to the optical properties of the sample.
Collapse
Affiliation(s)
- Andrew J. Gomes
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60218, USA
| | - Vladimir Turzhitsky
- Biomedical Imaging and Spectroscopy Laboratory, Departments of Medicine and Obstetrics and Gynecology and Reproductive Biology, Beth Israel Deaconess Medical Center, Harvard University, Boston, Massachusetts 02215, USA
| | - Sarah Ruderman
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60218, USA
| | - Vadim Backman
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60218, USA
- Corresponding author:
| |
Collapse
|
15
|
Oh S, Stewart T, Miller I, Bhatia S, Ragheb J, Duchowny M, Jayakar P, Lin WC. In vivo optical properties of cortical tubers in children with tuberous sclerosis complex (TSC): a preliminary investigation. Epilepsia 2011; 52:1699-704. [DOI: 10.1111/j.1528-1167.2011.03167.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Yu B, Fu HL, Ramanujam N. Instrument independent diffuse reflectance spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:011010. [PMID: 21280897 PMCID: PMC3041242 DOI: 10.1117/1.3524303] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative tissue characterization and disease diagnosis. Significant systematic errors can arise in the measured reflectance spectra and thus in the derived tissue physiological and morphological parameters due to real-time instrument fluctuations. We demonstrate a novel fiber optic probe with real-time, self-calibration capability that can be used for UV-visible diffuse reflectance spectroscopy in biological tissue in clinical settings. The probe is tested in a number of synthetic liquid phantoms over a wide range of tissue optical properties for significant variations in source intensity fluctuations caused by instrument warm up and day-to-day drift. While the accuracy for extraction of absorber concentrations is comparable to that achieved with the traditional calibration (with a reflectance standard), the accuracy for extraction of reduced scattering coefficients is significantly improved with the self-calibration probe compared to traditional calibration. This technology could be used to achieve instrument-independent diffuse reflectance spectroscopy in vivo and obviate the need for instrument warm up and post∕premeasurement calibration, thus saving up to an hour of precious clinical time.
Collapse
Affiliation(s)
- Bing Yu
- Duke University, Department of Biomedical Engineering, Durham, North Carolina 27708, USA.
| | | | | |
Collapse
|
17
|
Schwarz RA, Gao W, Stepanek VMT, Le TT, Bhattar VS, Williams MD, Wu JK, Vigneswaran N, Adler-Storthz K, Gillenwater AM, Richards-Kortum R. Prospective evaluation of a portable depth-sensitive optical spectroscopy device to identify oral neoplasia. BIOMEDICAL OPTICS EXPRESS 2010; 2:89-99. [PMID: 21326639 PMCID: PMC3028502 DOI: 10.1364/boe.2.000089] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2010] [Revised: 12/03/2010] [Accepted: 12/06/2010] [Indexed: 05/14/2023]
Abstract
A portable, depth-sensitive clinical spectroscopy device for noninvasive early diagnosis of oral cancer is described. We carried out a pilot study to evaluate the ability of the device to identify oral neoplasia using a previously developed diagnostic algorithm. A total of 79 oral sites in 33 subjects, including 28 patients with oral lesions and 5 healthy volunteers, were measured and analyzed. Measurements of 54 nonkeratinized oral sites yielded an area under the receiver operating characteristic curve of 0.90. Measurements of 25 keratinized oral sites yielded an area under the receiver operating characteristic curve of 0.83.
Collapse
Affiliation(s)
- Richard A. Schwarz
- Department of Bioengineering, Rice University, 6100 Main Street, Houston, TX 77005, USA
| | - Wen Gao
- Department of Bioengineering, Rice University, 6100 Main Street, Houston, TX 77005, USA
| | - Vanda M. T. Stepanek
- Department of Head and Neck Surgery, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA
| | - Tao T. Le
- Department of Head and Neck Surgery, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA
| | - Vijayashree S. Bhattar
- Department of Head and Neck Surgery, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA
| | - Michelle D. Williams
- Department of Pathology, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA
| | - Jessica K. Wu
- University of Texas Dental Branch at Houston, 6516 M. D. Anderson Boulevard, Houston, TX 77030, USA
| | - Nadarajah Vigneswaran
- University of Texas Dental Branch at Houston, 6516 M. D. Anderson Boulevard, Houston, TX 77030, USA
| | - Karen Adler-Storthz
- University of Texas Dental Branch at Houston, 6516 M. D. Anderson Boulevard, Houston, TX 77030, USA
| | - Ann M. Gillenwater
- Department of Head and Neck Surgery, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA
| | | |
Collapse
|
18
|
Mallia RJ, Subhash N, Mathews A, Kumar R, Thomas SS, Sebastian P, Madhavan J. Clinical grading of oral mucosa by curve-fitting of corrected autofluorescence using diffuse reflectance spectra. Head Neck 2010; 32:763-79. [PMID: 19827122 DOI: 10.1002/hed.21251] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Laser-induced autofluorescence (LIAF) and diffuse reflectance (DR) were collectively used in this clinical study to improve early oral cancer diagnosis and tissue grading. METHODS LIAF and DR emission from oral mucosa were recorded on a fiber-optic spectrometer by illumination with a 404-nm diode laser and tungsten halogen lamp in 36 healthy volunteers and 40 lesions of 20 patients. RESULTS Absorption dips in LIAF spectra at 545 and 575 nm resulting from changes in oxygenated hemoglobin were corrected using DR spectra of the same site. These corrected spectra were curve-fitted using Gaussian spectral functions to determine constituent emission peaks and their relative contribution. The Gaussian peak intensity and area ratios F500/F635 and F500/F685 were found to be useful indicators of tissue transformation. The diagnostic capability of various ratios in differentiating healthy, hyperplastic, dysplastic, and squamous cell carcinomas (SCCs) were examined using discrimination scatterplots. CONCLUSIONS The LIAF/DR technique, in conjunction with curve-fitting, differentiates different grades of dysplasia and SCC in this clinical trial and proves its potential for early detection of oral cavity cancer and tissue grading.
Collapse
|
19
|
Arifler D. Sensitivity of spatially resolved reflectance signals to coincident variations in tissue optical properties. APPLIED OPTICS 2010; 49:4310-20. [PMID: 20676188 DOI: 10.1364/ao.49.004310] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Canonical correlation analysis, a multivariate statistical technique, was used to investigate the degree of association between tissue optical properties and spatially resolved reflectance signals. Monte Carlo modeling was employed to simulate signals corresponding to different combinations of optical properties and these data sets were fed as input to statistical analysis. The results show that it is possible to adjust the separation and angular orientation of source and detector fibers such that the effect of a particular optical property will be augmented among coincident variations in other properties. The trends observed exhibit differences when compared with a conventional univariate sensitivity analysis in which only a single property is varied whereas all other parameters of interest are kept constant.
Collapse
Affiliation(s)
- Dizem Arifler
- Department of Physics, Eastern Mediterranean University, Famagusta, Cyprus.
| |
Collapse
|
20
|
Kan CW, Lee AY, Nieman LT, Sokolov K, Markey MK. Adaptive spectral window sizes for extraction of diagnostic features from optical spectra. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:047012. [PMID: 20799843 PMCID: PMC3188638 DOI: 10.1117/1.3481143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2010] [Revised: 06/26/2010] [Accepted: 07/01/2010] [Indexed: 05/29/2023]
Abstract
We present an approach to adaptively adjust the spectral window sizes for optical spectra feature extraction. Previous studies extracted features from spectral windows of a fixed width. In our algorithm, piecewise linear regression is used to adaptively adjust the window sizes to find the maximum window size with reasonable linear fit with the spectrum. This adaptive windowing technique ensures the signal linearity in defined windows; hence, the adaptive windowing technique retains more diagnostic information while using fewer windows. This method was tested on a data set of diffuse reflectance spectra of oral mucosa lesions. Eight features were extracted from each window. We performed classifications using linear discriminant analysis with cross-validation. Using windowing techniques results in better classification performance than not using windowing. The area under the receiver-operating-characteristics curve for windowing techniques was greater than a nonwindowing technique for both normal versus mild dysplasia (MD) plus severe high-grade dysplasia or carcinama (SD) (MD+SD) and benign versus MD+SD. Although adaptive and fixed-size windowing perform similarly, adaptive windowing utilizes significantly fewer windows than fixed-size windows (number of windows per spectrum: 8 versus 16). Because adaptive windows retain most diagnostic information while reducing the number of windows needed for feature extraction, our results suggest that it isolates unique diagnostic features in optical spectra.
Collapse
Affiliation(s)
- Chih-wen Kan
- The University of Texas, Department of Biomedical Engineering, Austin, Texas 78712-1084, USA
| | | | | | | | | |
Collapse
|
21
|
|
22
|
Zhu Y, Terry NG, Wax A. Scanning fiber angle-resolved low coherence interferometry. OPTICS LETTERS 2009; 34:3196-8. [PMID: 19838271 PMCID: PMC2830667 DOI: 10.1364/ol.34.003196] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We present a fiber-optic probe for Fourier-domain angle-resolved low coherence interferometry for the determination of depth-resolved scatterer size. The probe employs a scanning single-mode fiber to collect the angular scattering distribution of the sample, which is analyzed using the Mie theory to obtain the average size of the scatterers. Depth sectioning is achieved with low coherence Mach-Zehnder interferometry. In the sample arm of the interferometer, a fixed fiber illuminates the sample through an imaging lens and a collection fiber samples the backscattered angular distribution by scanning across the Fourier plane image of the sample. We characterize the optical performance of the probe and demonstrate the ability to execute depth-resolved sizing with subwavelength accuracy by using a double-layer phantom containing two sizes of polystyrene microspheres.
Collapse
|
23
|
Quantitative physiology of the precancerous cervix in vivo through optical spectroscopy. Neoplasia 2009; 11:325-32. [PMID: 19308287 DOI: 10.1593/neo.81386] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2008] [Revised: 01/14/2009] [Accepted: 01/16/2009] [Indexed: 11/18/2022] Open
Abstract
Cervical cancer is the second most common female cancer worldwide. The ability to quantify physiological and morphological changes in the cervix is not only useful in the diagnosis of cervical precancers but also important in aiding the design of cost-effective detection systems for use in developing countries that lack well-established screening and diagnostic programs. We assessed the capability of a diffuse reflectance spectroscopy technique to identify contrasts in optical biomarkers that vary with different grades of cervical intraepithelial neoplasia (CIN) from normal cervical tissues. The technology consists of an optical probe and an instrument (with broadband light source, dispersive element, and detector), and a Monte Carlo algorithm to extract optical biomarker contributions including total hemoglobin (Hb) concentration, Hb saturation, and reduced scattering coefficient from the measured spectra. Among 38 patients and 89 sites examined, 46 squamous normal sites, 18 CIN 1, and 15 CIN 2(+) sites were included in the analysis. Total Hb was statistically higher in CIN 2(+) (18.3 +/- 3.6 microM, mean +/- SE) compared with normal (9.58 +/- 1.91 microM) and CIN 1 (12.8 +/- 2.6 microM), whereas scattering was significantly reduced in CIN 1 (8.3 +/- 0.8 cm(-1)) and CIN 2(+) (8.6 +/- 1.0 cm(-1)) compared with normal (10.2 +/- 1.1 cm(-1)). Hemoglobin saturation was not significantly altered in CIN 2(+) compared with normal and CIN 1. The difference in total Hb is likely because of stromal angiogenesis, whereas decreased scattering can be attributed to breakdown of collagen network in the cervical stroma.
Collapse
|
24
|
Nieman LT, Jakovljevic M, Sokolov K. Compact beveled fiber optic probe design for enhanced depth discrimination in epithelial tissues. OPTICS EXPRESS 2009; 17:2780-96. [PMID: 19219183 DOI: 10.1364/oe.17.002780] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report the development and evaluation of a simple compact probe that incorporates multiple beveled fibers for depth sensitive detection of spectroscopic signals in vivo. We evaluated three probes with bevel angles 35, 40, and 45 degrees for their collection efficiency and depth resolution using a thin highly scattering white substrate and found that a 40 degree bevel provides the best characteristics for depth-resolved spectroscopy. The depth sensitivity of the probe with 40 degree beveled fibers was then evaluated using multilayer phantoms with scattering properties mimicking precancerous tissue and in vivo on normal human oral mucosa. The results demonstrate that the use of multiple beveled fibers has the capability to simultaneously collect scattering spectra from a range of depths within epithelial tissue that has the potential to provide further significant improvement of detection and monitorin of epithelial precancers.
Collapse
Affiliation(s)
- Linda T Nieman
- Department of Biomedical Engineering, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Boulevard, Austin, TX 77030, USA.
| | | | | |
Collapse
|
25
|
Sampat MP, Patel AC, Wang Y, Gupta S, Kan CW, Bovik AC, Markey MK. Indexes for three-class classification performance assessment--an empirical comparison. ACTA ACUST UNITED AC 2009; 13:300-12. [PMID: 19171528 DOI: 10.1109/titb.2008.2009440] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Assessment of classifier performance is critical for fair comparison of methods, including considering alternative models or parameters during system design. The assessment must not only provide meaningful data on the classifier efficacy, but it must do so in a concise and clear manner. For two-class classification problems, receiver operating characteristic analysis provides a clear and concise assessment methodology for reporting performance and comparing competing systems. However, many other important biomedical questions cannot be posed as "two-class" classification tasks and more than two classes are often necessary. While several methods have been proposed for assessing the performance of classifiers for such multiclass problems, none has been widely accepted. The purpose of this paper is to critically review methods that have been proposed for assessing multiclass classifiers. A number of these methods provide a classifier performance index called the volume under surface (VUS). Empirical comparisons are carried out using 4 three-class case studies, in which three popular classification techniques are evaluated with these methods. Since the same classifier was assessed using multiple performance indexes, it is possible to gain insight into the relative strengths and weakness of the measures. We conclude that: 1) the method proposed by Scurfield provides the most detailed description of classifier performance and insight about the sources of error in a given classification task and 2) the methods proposed by He and Nakas also have great practical utility as they provide both the VUS and an estimate of the variance of the VUS. These estimates can be used to statistically compare two classification algorithms.
Collapse
Affiliation(s)
- Mehul P Sampat
- Center for Neurological Imaging, Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115, USA.
| | | | | | | | | | | | | |
Collapse
|