• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4619882)   Today's Articles (186)   Subscriber (49404)
For: Lindsay P, Rink A, Ruschin M, Jaffray D. Investigation of energy dependence of EBT and EBT-2 Gafchromic film. Med Phys 2010;37:571-6. [PMID: 20229865 DOI: 10.1118/1.3291622] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
Number Cited by Other Article(s)
1
Chan MF, Park J, Aydin R, Lim SB. Technical note: Energy dependence of the Gafchromic EBT4 film: Dose-response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x-ray beams. Med Phys 2023;50:3738-3745. [PMID: 36695666 PMCID: PMC10635410 DOI: 10.1002/mp.16240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 12/30/2022] [Accepted: 01/09/2023] [Indexed: 01/26/2023]  Open
2
Mittal A, Shaw R, Binjola A, Natanasabapathi G, Sharma DN. Paper based radiochromic film for the detection and measurement of therapeutic radiation doses in radiotherapy: A preliminary study. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2022.110696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
3
Méndez I, Rovira-Escutia JJ, Casar B. A protocol for accurate radiochromic film dosimetry using Radiochromic.com. Radiol Oncol 2021;55:369-378. [PMID: 34384012 PMCID: PMC8366735 DOI: 10.2478/raon-2021-0034] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 07/01/2021] [Indexed: 11/21/2022]  Open
4
Das IJ, Francescon P, Moran JM, Ahnesjö A, Aspradakis MM, Cheng CW, Ding GX, Fenwick JD, Saiful Huq M, Oldham M, Reft CS, Sauer OA. Report of AAPM Task Group 155: Megavoltage photon beam dosimetry in small fields and non-equilibrium conditions. Med Phys 2021;48:e886-e921. [PMID: 34101836 DOI: 10.1002/mp.15030] [Citation(s) in RCA: 53] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/06/2021] [Accepted: 06/02/2021] [Indexed: 12/14/2022]  Open
5
Joubert MM, van Eeden D, du Plessis FCP. The relation between XR-QA2 and RT-QA2 GafchromicTMfilm optical density and absorbed dose in water produced by radionuclides. Biomed Phys Eng Express 2021;7. [PMID: 33601352 DOI: 10.1088/2057-1976/abe7c3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 02/18/2021] [Indexed: 11/12/2022]
6
Niroomand‐Rad A, Chiu‐Tsao S, Grams MP, Lewis DF, Soares CG, Van Battum LJ, Das IJ, Trichter S, Kissick MW, Massillon‐JL G, Alvarez PE, Chan MF. Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55. Med Phys 2020;47:5986-6025. [DOI: 10.1002/mp.14497] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 09/15/2020] [Accepted: 09/17/2020] [Indexed: 12/12/2022]  Open
7
Murphy MK, Kamen J. Deciding between an X-Ray and 137Cs Irradiator - It's not just about Energy Spectra. Radiat Res 2019;192:493-506. [PMID: 31502907 DOI: 10.1667/rr15395.1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
8
Santibáñez M, Fuentealba M, Torres F, Vargas A. Experimental determination of the gadolinium dose enhancement in phantom irradiated with low energy X-ray sources by a spectrophotometer -Gafchromic-EBT3 dosimetry system. Appl Radiat Isot 2019;154:108857. [PMID: 31434044 DOI: 10.1016/j.apradiso.2019.108857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 08/10/2019] [Accepted: 08/12/2019] [Indexed: 01/22/2023]
9
Gräfe JL, Santos C, Pejović-Milić A. Dosimetry of a portable in vivo x-ray fluorescence system using EBT3 radiochromic film. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019;39:1031-1040. [PMID: 31307016 DOI: 10.1088/1361-6498/ab3237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
10
Darafsheh A, León-Marroquín EY, Mulrow DJ, Baradaran-Ghahfarokhi M, Zhao T, Khan R. On the spectral characterization of radiochromic films irradiated with clinical proton beams. ACTA ACUST UNITED AC 2019;64:135016. [DOI: 10.1088/1361-6560/ab23cd] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
11
Holla R, Khanna D, Pillai BK, Jafar Ali KV, Renil Mon PS, Clinto CO, Ganesh T. An Experimental Slope Method for a More Accurate Measurement of Relative Radiation Doses using Radiographic and Radiochromic Films and Its Application to Megavoltage Small-Field Dosimetry. J Med Phys 2019;44:145-155. [PMID: 31576063 PMCID: PMC6764177 DOI: 10.4103/jmp.jmp_17_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]  Open
12
Massillon-Jl G, Cabrera-Santiago A, Xicohténcatl-Hernández N. Relative efficiency of Gafchromic EBT3 and MD-V3 films exposed to low-energy photons and its influence on the energy dependence. Phys Med 2019;61:8-17. [PMID: 31151584 DOI: 10.1016/j.ejmp.2019.04.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 04/10/2019] [Accepted: 04/11/2019] [Indexed: 11/17/2022]  Open
13
Zhuang Y, Li Y, Zhu J, Chen L, Liu X. A trial for EBT3 film without batch-specific calibration using a neural network. Phys Med Biol 2019;64:05NT01. [PMID: 30625437 DOI: 10.1088/1361-6560/aafcbb] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
14
León‐Marroquín EY, Mulrow DJ, Khan R, Darafsheh A. Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams. Med Phys 2019;46:973-982. [DOI: 10.1002/mp.13330] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 11/05/2018] [Accepted: 11/26/2018] [Indexed: 11/05/2022]  Open
15
Méndez I, Polšak A, Hudej R, Casar B. The Multigaussian method: a new approach to mitigating spatial heterogeneities with multichannel radiochromic film dosimetry. Phys Med Biol 2018;63:175013. [PMID: 30101754 DOI: 10.1088/1361-6560/aad9c1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
16
Feng Y, Tiedje HF, Gagnon K, Fedosejevs R. Spectral calibration of EBT3 and HD-V2 radiochromic film response at high dose using 20 MeV proton beams. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018;89:043511. [PMID: 29716332 DOI: 10.1063/1.4996022] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
17
Li Y, Chen L, Zhu J, Liu X. The combination of the error correction methods of GAFCHROMIC EBT3 film. PLoS One 2017;12:e0181958. [PMID: 28750023 PMCID: PMC5531657 DOI: 10.1371/journal.pone.0181958] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Accepted: 07/10/2017] [Indexed: 11/18/2022]  Open
18
Miura H, Ozawa S, Hosono F, Sumida N, Okazue T, Yamada K, Nagata Y. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy. J Appl Clin Med Phys 2016;17:312-322. [PMID: 27929504 PMCID: PMC5690510 DOI: 10.1120/jacmp.v17i6.6281] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2015] [Revised: 07/26/2016] [Accepted: 07/25/2016] [Indexed: 12/31/2022]  Open
19
Effect of verification imaging on in vivo dosimetry results using Gafchromic EBT3 film. Phys Med 2016;32:1461-1465. [DOI: 10.1016/j.ejmp.2016.10.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 09/20/2016] [Accepted: 10/26/2016] [Indexed: 11/19/2022]  Open
20
Massillon-JL G, Muñoz-Molina ID, Díaz-Aguirre P. Optimum absorbed dose versus energy response of Gafchromic EBT2 and EBT3 films exposed to 20–160 kV x-rays and 60 Co gamma. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/4/045005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
21
Tamponi M, Bona R, Poggiu A, Marini P. A new form of the calibration curve in radiochromic dosimetry. Properties and results. Med Phys 2016;43:4435. [DOI: 10.1118/1.4954208] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
22
García-Garduño OA, Lárraga-Gutiérrez JM, Rodríguez-Villafuerte M, Martínez-Dávalos A, Rivera-Montalvo T. Effect of correction methods of radiochromic EBT2 films on the accuracy of IMRT QA. Appl Radiat Isot 2016;107:121-126. [PMID: 26492322 DOI: 10.1016/j.apradiso.2015.09.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 09/24/2015] [Accepted: 09/30/2015] [Indexed: 12/01/2022]
23
Gan GN, Altunbas C, Morton JJ, Eagles J, Backus J, Dzingle W, Raben D, Jimeno A. Radiation dose uncertainty and correction for a mouse orthotopic and xenograft irradiation model. Int J Radiat Biol 2015;92:50-6. [PMID: 26689828 DOI: 10.3109/09553002.2016.1114189] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
24
Lewis D, Devic S. Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system. Med Phys 2015;42:5692-701. [DOI: 10.1118/1.4929563] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
25
Vadrucci M, Esposito G, Ronsivalle C, Cherubini R, Marracino F, Montereali RM, Picardi L, Piccinini M, Pimpinella M, Vincenti MA, De Angelis C. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and 60 Co γ-rays. Med Phys 2015;42:4678-84. [DOI: 10.1118/1.4926558] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
26
Adolfsson E, White S, Landry G, Lund E, Gustafsson H, Verhaegen F, Reniers B, Carlsson Tedgren Å, Carlsson GA. Measurement of absorbed dose to water around an electronic brachytherapy source. Comparison of two dosimetry systems: lithium formate EPR dosimeters and radiochromic EBT2 film. Phys Med Biol 2015;60:3869-82. [PMID: 25906141 DOI: 10.1088/0031-9155/60/9/3869] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
27
Méndez I. Model selection for radiochromic film dosimetry. Phys Med Biol 2015;60:4089-104. [DOI: 10.1088/0031-9155/60/10/4089] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
28
Reinhardt S, Würl M, Greubel C, Humble N, Wilkens JJ, Hillbrand M, Mairani A, Assmann W, Parodi K. Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2015;54:71-79. [PMID: 25572031 DOI: 10.1007/s00411-014-0581-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 12/16/2014] [Indexed: 06/04/2023]
29
Morrison H, Menon G, Sloboda RS. Radiochromic film calibration for low-energy seed brachytherapy dose measurement. Med Phys 2015;41:072101. [PMID: 24989396 DOI: 10.1118/1.4881146] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
30
Sharma S, Moros EG, Boerma M, Sridharan V, Han EY, Clarkson R, Hauer-Jensen M, Corry PM. A novel technique for image-guided local heart irradiation in the rat. Technol Cancer Res Treat 2014;13:593-603. [PMID: 24000983 PMCID: PMC3951712 DOI: 10.7785/tcrtexpress.2013.600256] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Revised: 01/28/2013] [Accepted: 01/30/2013] [Indexed: 11/06/2022]  Open
31
Subiel A, Moskvin V, Welsh GH, Cipiccia S, Reboredo D, Evans P, Partridge M, DesRosiers C, Anania MP, Cianchi A, Mostacci A, Chiadroni E, Di Giovenale D, Villa F, Pompili R, Ferrario M, Belleveglia M, Di Pirro G, Gatti G, Vaccarezza C, Seitz B, Isaac RC, Brunetti E, Wiggins SM, Ersfeld B, Islam MR, Mendonca MS, Sorensen A, Boyd M, Jaroszynski DA. Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: using radiochromic film measurements and Monte Carlo simulations. Phys Med Biol 2014;59:5811-29. [PMID: 25207591 DOI: 10.1088/0031-9155/59/19/5811] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
32
Méndez I, Peterlin P, Hudej R, Strojnik A, Casar B. On multichannel film dosimetry with channel-independent perturbations. Med Phys 2014;41:011705. [PMID: 24387497 DOI: 10.1118/1.4845095] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
33
García-Garduño OA, Rodríguez-Ponce M, Gamboa-deBuen I, Rodríguez-Villafuerte M, Galván de la Cruz OO, Rivera-Montalvo T. Effect of dosimeter type for commissioning small photon beams on calculated dose distribution in stereotactic radiosurgery. Med Phys 2014;41:092101. [DOI: 10.1118/1.4892176] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
34
Schoenfeld AA, Poppinga D, Harder D, Doerner KJ, Poppe B. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers. Phys Med Biol 2014;59:3575-97. [DOI: 10.1088/0031-9155/59/13/3575] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
35
McCaw TJ, Micka JA, DeWerd LA. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Med Phys 2014;41:052104. [DOI: 10.1118/1.4871781] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
36
Lindsay PE, Granton PV, Gasparini A, Jelveh S, Clarkson R, van Hoof S, Hermans J, Kaas J, Wittkamper F, Sonke JJ, Verhaegen F, Jaffray DA. Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators. Med Phys 2014;41:031714. [DOI: 10.1118/1.4866215] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
37
Hill R, Healy B, Holloway L, Kuncic Z, Thwaites D, Baldock C. Advances in kilovoltage x-ray beam dosimetry. Phys Med Biol 2014;59:R183-231. [DOI: 10.1088/0031-9155/59/6/r183] [Citation(s) in RCA: 110] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
38
Chan MF, Lewis D, Yu X. Is It Possible to Publish a Calibration Function for Radiochromic Film? INTERNATIONAL JOURNAL OF MEDICAL PHYSICS, CLINICAL ENGINEERING AND RADIATION ONCOLOGY 2014;3:25-30. [PMID: 27642545 PMCID: PMC5023153 DOI: 10.4236/ijmpcero.2014.31005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
39
Bekerat H, Devic S, DeBlois F, Singh K, Sarfehnia A, Seuntjens J, Shih S, Yu X, Lewis D. Improving the energy response of external beam therapy (EBT) GafChromicTM dosimetry films at low energies (≤100 keV). Med Phys 2014;41:022101. [DOI: 10.1118/1.4860157] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
40
Villarreal-Barajas JE, Khan RFH. Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range. J Appl Clin Med Phys 2014;15:4439. [PMID: 24423839 PMCID: PMC5711253 DOI: 10.1120/jacmp.v15i1.4439] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2013] [Revised: 08/04/2013] [Accepted: 07/18/2013] [Indexed: 11/23/2022]  Open
41
Perles LA, Mirkovic D, Anand A, Titt U, Mohan R. LET dependence of the response of EBT2 films in proton dosimetry modeled as a bimolecular chemical reaction. Phys Med Biol 2013;58:8477-91. [DOI: 10.1088/0031-9155/58/23/8477] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
42
Thompson L, Dias HG, Campos TPR. Dosimetry in brain tumor phantom at 15 MV 3D conformal radiation therapy. Radiat Oncol 2013;8:168. [PMID: 23829593 PMCID: PMC3729429 DOI: 10.1186/1748-717x-8-168] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2013] [Accepted: 06/18/2013] [Indexed: 11/17/2022]  Open
43
Moylan R, Aland T, Kairn T. Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2013;36:331-7. [PMID: 23801092 DOI: 10.1007/s13246-013-0206-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2013] [Accepted: 06/12/2013] [Indexed: 11/26/2022]
44
Uehara R, Tachibana H, Ito Y, Yoshino S, Matsubayashi F, Sato T. [A practical procedure to improve the accuracy of radiochromic film dosimetry: a integration with a correction method of uniformity correction and a red/blue correction method]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2013;69:617-31. [PMID: 23782774 DOI: 10.6009/jjrt.2013_jsrt_69.6.617] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
45
Wack L, Ngwa W, Tryggestad E, Tsiamas P, Berbeco R, Ng SK, Hesser J, Zygmanski P. High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator. Phys Med 2013;30:36-46. [PMID: 23510532 DOI: 10.1016/j.ejmp.2013.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 02/04/2013] [Accepted: 02/11/2013] [Indexed: 10/27/2022]  Open
46
Brown TAD, Hogstrom KR, Alvarez D, Matthews KL, Ham K, Dugas JP. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams. Med Phys 2013;39:7412-7. [PMID: 23231291 DOI: 10.1118/1.4767770] [Citation(s) in RCA: 94] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
47
Hsiao MC, Liu YH, Chen WL, Jiang SH. Neutron response of GafChromic® EBT2 film. Phys Med Biol 2013;58:1391-413. [DOI: 10.1088/0031-9155/58/5/1391] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
48
Akino Y, Das IJ, Bartlett GK, Zhang H, Thompson E, Zook JE. Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques. Med Phys 2012;40:011714. [PMID: 23298084 DOI: 10.1118/1.4770285] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
49
Lewis D, Micke A, Yu X, Chan MF. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan. Med Phys 2012;39:6339-50. [PMID: 23039670 DOI: 10.1118/1.4754797] [Citation(s) in RCA: 266] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
50
Girard F, Bouchard H, Lacroix F. Reference dosimetry using radiochromic film. J Appl Clin Med Phys 2012;13:3994. [PMID: 23149793 PMCID: PMC5718535 DOI: 10.1120/jacmp.v13i6.3994] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2012] [Revised: 06/27/2012] [Accepted: 07/22/2012] [Indexed: 11/23/2022]  Open
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA