1
|
Chen M, Mu L, Wang S, Cao X, Liang S, Wang Y, She G, Yang J, Wang Y, Shi W. A Single Silicon Nanowire-Based Ratiometric Biosensor for Ca 2+ at Various Locations in a Neuron. ACS Chem Neurosci 2020; 11:1283-1290. [PMID: 32293869 DOI: 10.1021/acschemneuro.0c00041] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Ionic calcium (Ca2+) is an important second messenger in cells, particularly in the neuron. A deficiency or excess of Ca2+ would lead to neuronal apoptosis and further injury to the brain. For accurate analysis of intracellular Ca2+, a single silicon nanowire (SiNW)-based ratiometric biosensor was constructed by simultaneously anchoring Ru(bpy)2(mcbpy-O-Su-ester)(PF6)2, as a reference molecule, and Fluo-3, as a response molecule, onto the surface of a single SiNW. The SiNW-based biosensor exhibits high sensitivity and favorable selectivity for detecting Ca2+. With the assistance of a micromanipulator and laser scanning confocal microscope, two single SiNW sensors were placed in the body and the neurites of an individual neuron to detect Ca2+. The difference between the concentrations of Ca2+ in the body and neurites was identified. The results from the present study provide new insights into Ca2+ in neurons at a high spatial resolution, and the strategy used in this study provides a new opportunity to investigate cellular metabolism by combining the advantages of a single-cell detection technique and physiology.
Collapse
Affiliation(s)
- Min Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lixuan Mu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Shuai Wang
- State Key Laboratory of Toxicology and Medical Countermeasures, Institutes of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Xingxing Cao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Sen Liang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yuan Wang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Guangwei She
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Jun Yang
- State Key Laboratory of Toxicology and Medical Countermeasures, Institutes of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Yongan Wang
- State Key Laboratory of Toxicology and Medical Countermeasures, Institutes of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Wensheng Shi
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
2
|
Sakata T. Biologically Coupled Gate Field-Effect Transistors Meet in Vitro Diagnostics. ACS OMEGA 2019; 4:11852-11862. [PMID: 31460295 PMCID: PMC6682067 DOI: 10.1021/acsomega.9b01629] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 06/26/2019] [Indexed: 05/22/2023]
Abstract
In this paper, recent works on biologically coupled gate field-effect transistor (bio-FET) sensors are introduced and compared to provide a perspective. Most biological phenomena are closely related to behaviors of ions and biomolecules. This is why biosensing devices for detecting ionic and biomolecular charges contribute to the direct analysis of biological phenomena in a label-free and enzyme-free manner. Potentiometric biosensors such as bio-FET sensors, which allow the direct detection of these charges on the basis of the field effect, meet this requirement and have been developed as simple devices for in vitro diagnostics (IVD). A variety of biological ionic behaviors generated by biomolecular recognition events and cellular activities are being targeted for clinical diagnostics as well as the study of neuroscience using the bio-FET sensors. To realize these applications, bioelectrical interfaces should be formed between the electrolyte solution and the gate electrode by modifying artificially synthesized and biomimetic membranes, resulting in the selective detection of targets based on intrinsic molecular charges. Various types of semiconducting materials, not only inorganic semiconductors but also organic semiconductors, can be selected for use in bio-FET sensors, depending on the application field. In addition, a semiconductor integrated circuit device is ideal for the massively parallel detection of multiple samples. Thus, platforms based on bio-FET sensors are suitable for use in simple and miniaturized electrical circuit systems for IVD to enable the prevention and early detection of diseases.
Collapse
|
3
|
Zeck G, Jetter F, Channappa L, Bertotti G, Thewes R. Electrical Imaging: Investigating Cellular Function at High Resolution. ACTA ACUST UNITED AC 2017; 1:e1700107. [DOI: 10.1002/adbi.201700107] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 07/27/2017] [Indexed: 12/26/2022]
Affiliation(s)
- Günther Zeck
- Neurophysics, Natural and Medical Sciences Institute at the University Tübingen; 72770 Reutlingen Germany
| | - Florian Jetter
- Neurophysics, Natural and Medical Sciences Institute at the University Tübingen; 72770 Reutlingen Germany
| | - Lakshmi Channappa
- Neurophysics, Natural and Medical Sciences Institute at the University Tübingen; 72770 Reutlingen Germany
| | - Gabriel Bertotti
- Chair of Sensor and Actuator Systems; Technical University of Berlin; 10587 Berlin Germany
| | - Roland Thewes
- Chair of Sensor and Actuator Systems; Technical University of Berlin; 10587 Berlin Germany
| |
Collapse
|
4
|
Affiliation(s)
- Eduardo Fernández
- Bioengineering Institute; Miguel Hernández University of Elche and CIBER BBN; Elche 03202 Spain
| | - Pablo Botella
- Instituto de Tecnología Química; Universitat Politècnica de València-Consejo Superior de Investigaciones Científicas; Valencia 46022 Spain
| |
Collapse
|
5
|
Kang H, Kim JY, Choi YK, Nam Y. Feasibility Study of Extended-Gate-Type Silicon Nanowire Field-Effect Transistors for Neural Recording. SENSORS (BASEL, SWITZERLAND) 2017; 17:E705. [PMID: 28350370 PMCID: PMC5421665 DOI: 10.3390/s17040705] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/08/2017] [Accepted: 03/23/2017] [Indexed: 01/22/2023]
Abstract
In this research, a high performance silicon nanowire field-effect transistor (transconductance as high as 34 µS and sensitivity as 84 nS/mV) is extensively studied and directly compared with planar passive microelectrode arrays for neural recording application. Electrical and electrochemical characteristics are carefully characterized in a very well-controlled manner. We especially focused on the signal amplification capability and intrinsic noise of the transistors. A neural recording system using both silicon nanowire field-effect transistor-based active-type microelectrode array and platinum black microelectrode-based passive-type microelectrode array are implemented and compared. An artificial neural spike signal is supplied as input to both arrays through a buffer solution and recorded simultaneously. Recorded signal intensity by the silicon nanowire transistor was precisely determined by an electrical characteristic of the transistor, transconductance. Signal-to-noise ratio was found to be strongly dependent upon the intrinsic 1/f noise of the silicon nanowire transistor. We found how signal strength is determined and how intrinsic noise of the transistor determines signal-to-noise ratio of the recorded neural signals. This study provides in-depth understanding of the overall neural recording mechanism using silicon nanowire transistors and solid design guideline for further improvement and development.
Collapse
Affiliation(s)
- Hongki Kang
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
| | - Jee-Yeon Kim
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
| | - Yang-Kyu Choi
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
- KAIST Institute for the NanoCentury, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
| | - Yoonkey Nam
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
- KAIST Institute for the NanoCentury, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea.
| |
Collapse
|
6
|
Fromherz P. Current-Induced Transistor Sensorics with Electrogenic Cells. BIOSENSORS-BASEL 2016; 6:18. [PMID: 27120627 PMCID: PMC4931478 DOI: 10.3390/bios6020018] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 03/31/2016] [Accepted: 04/12/2016] [Indexed: 11/22/2022]
Abstract
The concepts of transistor recording of electroactive cells are considered, when the response is determined by a current-induced voltage in the electrolyte due to cellular activity. The relationship to traditional transistor recording, with an interface-induced response due to interactions with the open gate oxide, is addressed. For the geometry of a cell-substrate junction, the theory of a planar core-coat conductor is described with a one-compartment approximation. The fast electrical relaxation of the junction and the slow change of ion concentrations are pointed out. On that basis, various recording situations are considered and documented by experiments. For voltage-gated ion channels under voltage clamp, the effects of a changing extracellular ion concentration and the enhancement/depletion of ion conductances in the adherent membrane are addressed. Inhomogeneous ion conductances are crucial for transistor recording of neuronal action potentials. For a propagating action potential, the effects of an axon-substrate junction and the surrounding volume conductor are distinguished. Finally, a receptor-transistor-sensor is described, where the inhomogeneity of a ligand–activated ion conductance is achieved by diffusion of the agonist and inactivation of the conductance. Problems with regard to a development of reliable biosensors are mentioned.
Collapse
Affiliation(s)
- Peter Fromherz
- Max-Planck-Institute for Biochemistry, Am Klopferspitz 18, Martinsried-München 82152, Germany.
| |
Collapse
|
7
|
Bakkum DJ, Frey U, Radivojevic M, Russell TL, Müller J, Fiscella M, Takahashi H, Hierlemann A. Tracking axonal action potential propagation on a high-density microelectrode array across hundreds of sites. Nat Commun 2014; 4:2181. [PMID: 23867868 DOI: 10.1038/ncomms3181] [Citation(s) in RCA: 135] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2013] [Accepted: 06/24/2013] [Indexed: 12/22/2022] Open
Abstract
Axons are traditionally considered stable transmission cables, but evidence of the regulation of action potential propagation demonstrates that axons may have more important roles. However, their small diameters render intracellular recordings challenging, and low-magnitude extracellular signals are difficult to detect and assign. Better experimental access to axonal function would help to advance this field. Here we report methods to electrically visualize action potential propagation and network topology in cortical neurons grown over custom arrays, which contain 11,011 microelectrodes and are fabricated using complementary metal oxide semiconductor technology. Any neuron lying on the array can be recorded at high spatio-temporal resolution, and simultaneously precisely stimulated with little artifact. We find substantial velocity differences occurring locally within single axons, suggesting that the temporal control of a neuron's output may contribute to neuronal information processing.
Collapse
Affiliation(s)
- Douglas J Bakkum
- Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Timko BP, Patolsky F, Lieber CM. Response to Comment on "Detection, Stimulation, and Inhibition of Neuronal Signals with High-Density Nanowire Transistor Arrays". Science 2009; 323:1429; author reply 1429. [DOI: 10.1126/science.1155917] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|