1
|
Chen H, Liu K, Li Z, Wang P. Point of care testing for infectious diseases. Clin Chim Acta 2019; 493:138-147. [PMID: 30853460 PMCID: PMC6462423 DOI: 10.1016/j.cca.2019.03.008] [Citation(s) in RCA: 138] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/06/2019] [Accepted: 03/06/2019] [Indexed: 01/06/2023]
Abstract
Infectious diseases are caused by pathogenic microorganisms and can be transmitted between individuals and populations thus threatening the general public health and potentially the economy. Efficient diagnostic tools are needed to provide accurate and timely guidance for case identification, transmission disruption and appropriate treatment administration. Point of care (POC) tests provide actionable results near the patient and thereby serve as a personal "radar". In this review, we review clinical needs for POC testing for several major pathogens, including malaria parasites, human immunodeficiency virus (HIV), human papillomavirus (HPV), dengue, Ebola and Zika viruses and Mycobacterium tuberculosis (TB). We compare different molecular approaches, including pathogen nucleic acid and protein, circulating microRNA and antibodies, used in the POC tests. Finally, we review recent advances in novel POC technologies focusing on microfluidic and plasmonic-based approaches.
Collapse
Affiliation(s)
- Hui Chen
- Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Kengku Liu
- Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Zhao Li
- Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Ping Wang
- Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States.
| |
Collapse
|
2
|
Abstract
HIV diagnostics have played a central role in the remarkable progress in identifying, staging, initiating, and monitoring infected individuals on life-saving antiretroviral therapy. They are also useful in surveillance and outbreak responses, allowing for assessment of disease burden and identification of vulnerable populations and transmission "hot spots," thus enabling planning, appropriate interventions, and allocation of appropriate funding. HIV diagnostics are critical in achieving epidemic control and require a hybrid of conventional laboratory-based diagnostic tests and new technologies, including point-of-care (POC) testing, to expand coverage, increase access, and positively impact patient management. In this review, we provide (i) a historical perspective on the evolution of HIV diagnostics (serologic and molecular) and their interplay with WHO normative guidelines, (ii) a description of the role of conventional and POC testing within the tiered laboratory diagnostic network, (iii) information on the evaluations and selection of appropriate diagnostics, (iv) a description of the quality management systems needed to ensure reliability of testing, and (v) strategies to increase access while reducing the time to return results to patients. Maintaining the central role of HIV diagnostics in programs requires periodic monitoring and optimization with quality assurance in order to inform adjustments or alignment to achieve epidemic control.
Collapse
|
3
|
Tay A, Pavesi A, Yazdi SR, Lim CT, Warkiani ME. Advances in microfluidics in combating infectious diseases. Biotechnol Adv 2016; 34:404-421. [PMID: 26854743 PMCID: PMC7125941 DOI: 10.1016/j.biotechadv.2016.02.002] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Revised: 02/03/2016] [Accepted: 02/04/2016] [Indexed: 12/11/2022]
Abstract
One of the important pursuits in science and engineering research today is to develop low-cost and user-friendly technologies to improve the health of people. Over the past decade, research efforts in microfluidics have been made to develop methods that can facilitate low-cost diagnosis of infectious diseases, especially in resource-poor settings. Here, we provide an overview of the recent advances in microfluidic devices for point-of-care (POC) diagnostics for infectious diseases and emphasis is placed on malaria, sepsis and AIDS/HIV. Other infectious diseases such as SARS, tuberculosis, and dengue are also briefly discussed. These infectious diseases are chosen as they contribute the most to disability-adjusted life-years (DALYs) lost according to the World Health Organization (WHO). The current state of research in this area is evaluated and projection toward future applications and accompanying challenges are also discussed.
Collapse
Affiliation(s)
- Andy Tay
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore 117575, Singapore; Department of Bioengineering, University of California Los Angeles, CA 90025, United States
| | - Andrea Pavesi
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore
| | - Saeed Rismani Yazdi
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Polytechnic University of Milan, Milan 20133, Italy
| | - Chwee Teck Lim
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Mechanobiology Institute, National University of Singapore, Singapore 117411, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore 117575, Singapore
| | - Majid Ebrahimi Warkiani
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; School of Mechanical and Manufacturing Engineering, Australian Centre for NanoMedicine, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
4
|
Gossez M, Malcus C, Demaret J, Frater J, Poitevin-Later F, Monneret G. Evaluation of a novel automated volumetric flow cytometer for absolute CD4+ T lymphocyte quantitation. CYTOMETRY PART B-CLINICAL CYTOMETRY 2016; 92:456-464. [PMID: 26804473 DOI: 10.1002/cyto.b.21360] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 12/12/2015] [Accepted: 01/20/2016] [Indexed: 01/28/2023]
Abstract
BACKGROUND Bead-based single platform cytometry technology (SPT) is the gold standard when performing CD4 absolute counting. However, it presents drawbacks as precision depends on various critical steps (for example, pipetting methodology, overtime stability of beads, stability of fluidics, regular recalibration…) and thus requires skilled operators. The fully automated volumetric SPT AQUIOS CL (Beckman Coulter) has recently emerged as an alternative with no need of beads. It may help improving results standardisation and fulfilling requirements for certification (ISO 15189). In this study, we assessed SPT AQUIOS CL performances in accordance to requirements for ISO 15189 accreditation. METHODS We evaluated repeatability and reproducibility (precision), bias (trueness), uncertainty (total error), range limits (linearity, quantification, detection limits), and inter-reagent/inter-sample contaminations in enumerating CD4+ T-cells. Concomitantly, we compared AQUIOS CL CD4+ T-cell values with the results obtained with our routine bead-based SPT (that is, FC500 Beckman Coulter, bead-based SPT), on blood samples from 148 patients representative of clinical laboratory routine workload. RESULTS Every result (repeatability, reproducibility, trueness, total error) was below the acceptable thresholds proposed in international recommendations. Contamination results and range limits (linearity, quantification, and detection limits) were all found perfectly suitable to routine analysis. The comparison between AQUIOS CL and FC500 exhibited excellent correlation and agreement (Pearson R = 0.99, P < 0.001; Lin's concordance correlation coefficient: Lin ρc = 0.991, Cb = 0.999), and Bland-Altman analysis did not reveal any systematic error. CONCLUSIONS Our results demonstrate that, upon subsequent validation in more routine conditions, the AQUIOS CL could be a suitable tool for clinical flow cytometry laboratories facing accreditation process. © 2016 International Clinical Cytometry Society.
Collapse
Affiliation(s)
- Morgane Gossez
- Hospices Civils De Lyon, Hôpital Edouard Herriot, Laboratoire D'immunologie, Lyon, F-69003, France.,Université Claude Bernard Lyon 1, Lyon, F-69008, France
| | - Christophe Malcus
- Hospices Civils De Lyon, Hôpital Edouard Herriot, Laboratoire D'immunologie, Lyon, F-69003, France
| | - Julie Demaret
- Hospices Civils De Lyon, Hôpital Edouard Herriot, Laboratoire D'immunologie, Lyon, F-69003, France.,Université Claude Bernard Lyon 1, Lyon, F-69008, France
| | | | - Françoise Poitevin-Later
- Hospices Civils De Lyon, Hôpital Edouard Herriot, Laboratoire D'immunologie, Lyon, F-69003, France
| | - Guillaume Monneret
- Hospices Civils De Lyon, Hôpital Edouard Herriot, Laboratoire D'immunologie, Lyon, F-69003, France.,Université Claude Bernard Lyon 1, Lyon, F-69008, France
| |
Collapse
|
5
|
Shete A, Thakar M, Abraham PR, Paranjape R. A review on peripheral blood CD4+ T lymphocyte counts in healthy adult Indians. Indian J Med Res 2010; 132:667-75. [PMID: 21245613 PMCID: PMC3102453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The CD4+ T lymphocytes are the crucial cells in the cascade of events in forming immune response to the foreign antigen and hence monitoring the CD4+ T cell counts to understand the extent of immune deficiency is a common practice. CD4+ T cells are also the primary target cells for human immunodeficiency virus (HIV). Hence CD4+ T lymphocyte count is the most important marker of immune dysfunction in HIV disease progression. The estimation of CD4+ T cell counts is used to decide the initiation of anti retroviral therapy (ART), to monitor the efficacy of ART and to start treatment for opportunistic infections (OIs). To develop the threshold levels of CD4+ T cell counts, data from western countries are being used in India. The CD4+ T cell counts are known to be influenced by race and environmental factors. Hence it is important to establish the reference ranges for the CD4+ T cell counts in the target population to understand the immune dysfunction. The information on the lower limits of the CD4+ T cells count is necessary to decide the initiation and monitoring of ART. The published data on the CD4+ T cells count in healthy Indian adult population have been reviewed, analyzed and discussed in this review article. The requirement of establishment of reference ranges in Indian population is discussed.
Collapse
Affiliation(s)
- Ashwini Shete
- National AIDS Research Institute (ICMR), Pune, India
| | | | | | - Ramesh Paranjape
- National AIDS Research Institute (ICMR), Pune, India,Reprint requests: Dr R.S. Paranjape, Director, National AIDS Research Institute (ICMR), G-73, MIDC, Bhosari, Pune 411 026, India e-mail:
| |
Collapse
|
6
|
The Use of Glutaraldehyde-Fixed Chicken Red Blood Cells as Counting Beads for Performing Affordable Single-Platform CD4+ T-Lymphocyte Count in HIV-1-Infected Patients. J Acquir Immune Defic Syndr 2010; 53:47-54. [DOI: 10.1097/qai.0b013e3181c4b8ae] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
7
|
Bae SY, Park HC, Oh JS, Yoon SY, Park DW, Choi IK, Kim HJ, Oh JH, Hur DS, Chung C, Chang JK, Robinson JP, Lim CS. Absolute CD4+cell count using a plastic microchip and a microscopic cell counter. CYTOMETRY PART B-CLINICAL CYTOMETRY 2009; 76:345-53. [DOI: 10.1002/cyto.b.20470] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Satué K, Hernández A, Lorente C, O'Connor JE. Immunophenotypical characterization in Andalusian horse: variations with age and gender. Vet Immunol Immunopathol 2009; 133:219-27. [PMID: 19735948 DOI: 10.1016/j.vetimm.2009.08.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2008] [Revised: 08/10/2009] [Accepted: 08/14/2009] [Indexed: 10/20/2022]
Abstract
Assessment of lymphocyte subsets is an effective method for characterizing disorders such as leukemia, lymphomas, autoimmune and infectious diseases. In order to clinically interpret these parameters, normal reference values should be set, estimating age- and gender-related variations. This research aimed to: (1) characterize lymphocyte subpopulations in Andalusian horse, and (2) evaluate age and gender-related variations of lymphocyte subsets. Jugular blood samples were obtained from 159 animals, 77 males and 82 females, belonging to four age groups-1: 1-2 years (N=39; 21 males and 18 females), 2: 2-3 years (N=38; 16 males and 22 females), 3: 3-4 years (N=41; 19 males and 22 females) and 4: 4-7 years (N=41; 21 males and 20 females). T lymphocytes subsets were quantified by flow cytometry with monoclonal antibodies specific for CD2, CD4 and CD8 cell markers. B and NK cell counts were estimated by using a mathematical formula. No variations were found in T, B lymphocytes and NK cells between males and females. Animals of group 1 and 2 had a higher number of CD2, T, CD4+, CD8+, B lymphocytes and NK cells than animals of groups 3 and 4. The percentage of CD2 in group 1 was significantly lower than in group 4. The percentage of T and CD4+ lymphocytes in the group 1 were significantly higher than groups 2 and 3, respectively. Whereas the percentage of B cells calculated by flow cytometry was significantly lower in group 2 compared to group 4, the percentage of B cells calculated by a mathematical formula was higher in group 1. NK cells percentage was significantly lower in group 3 and 4 than in younger animals. In conclusion, in Andalusian horse, gender does not influence absolute numbers and percentages of T, B and NK. There is an age-related decline in absolute number of CD2, T, CD4+ and CD8+ lymphocytes, B lymphocytes and NK cells, with increasing percentage of CD2, T, CD4+ and B lymphocytes, and a decrease in NK with no differences in CD4/CD8 ratio. The decline of lymphocyte population numbers with age is a natural process in many animal species, and could be the origin for immune dysfunction observed in geriatric individuals.
Collapse
Affiliation(s)
- K Satué
- Department of Medicine and Surgery, Faculty of Veterinary Medicine, Cardenal Herrera-CEU University, Valencia, Spain.
| | | | | | | |
Collapse
|
9
|
Mandy F, Brando B. Enumeration of absolute cell counts using immunophenotypic techniques. ACTA ACUST UNITED AC 2008; Chapter 6:Unit 6.8. [PMID: 18770719 DOI: 10.1002/0471142956.cy0608s13] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Absolute counting of cells or cell subsets has a number of significant clinical applications: monitoring the disease status of HIV-infected patients, enumerating residual white blood cells in leukoreduced blood products, and assessing immunodeficiency in a variety of situations. The single-platform method (flow cytometry alone) has emerged as the method of choice for absolute cell enumeration. This technology counts only the cells of interest in a precisely determined blood volume. Exact cell identification is accomplished by a logical electronic gating algorithm capable of identifying lineage-specific immunofluorescent markers. Exclusion of unwanted cells is automatic. This extensive and detailed unit presents protocols for both volumetric and flow-rate determination of residual white blood cells and of leukocyte subsets.
Collapse
Affiliation(s)
- F Mandy
- Health Canada, Ottawa, Canada
| | | |
Collapse
|
10
|
Li X, Ymeti A, Lunter B, Breukers C, Tibbe AGJ, Terstappen LWMM, Greve J. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings. CYTOMETRY PART B-CLINICAL CYTOMETRY 2007; 72:397-407. [PMID: 17311352 DOI: 10.1002/cyto.b.20165] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND HIV monitoring in resource-constrained settings demands affordable and reliable CD4(+) T lymphocytes enumeration methods. We developed a simple single platform image cytometer (SP ICM), which is a dedicated volumetric CD4(+) T lymphocytes enumeration system that uses immunomagnetic and immunofluorescent technologies. The instrument was designed to be a low-cost, yet reliable and robust one. In this article we test the instrument and the immunochemical procedures used on blood from HIV negative and HIV positive patients. METHODS After CD4 immunomagnetic labeling in whole blood, CD4(+) T lymphocytes, CD4(+dim) monocytes and some nonspecifically labeled cells are magnetically attracted to an analysis surface. Combining with CD3-Phycoerythrin (PE) labeling, only CD3(+)CD4(+) T lymphocytes are fluorescently labeled and visible in a fluorescent image of the analysis surface. The number of CD4(+) T lymphocytes is obtained by image analysis. Alternatively, CD3 immunomagnetic selection in combination with CD4 immunofluorescent labeling can also be applied for CD4(+) T lymphocytes enumeration. RESULTS The SP ICM system was compared with two single platform flow cytometer (SP FCM) methods: tetraCXP and TruCount methods. The SP ICM system has excellent precision, accuracy and linearity for CD4(+) T lymphocytes enumeration. Good correlations were obtained between the SP ICM and the SP FCM methods for blood specimens of 44 HIV(-) patients, and of 63 HIV(+) patients. Bland-Altman plots showed interchangeability between the SP ICM and the SP FCM methods. CONCLUSIONS The immunolabeling methods and the instrumentation are simple and easy-to-handle for less-trained operators. The SP ICM system is a good candidate for CD4(+) T lymphocytes enumeration in point-of-care settings of resource-constrained countries.
Collapse
Affiliation(s)
- Xiao Li
- University of Twente, Faculty of Science and Technology, Biophysical Engineering Group, Building Zuidhorst, Dienstweg 1, 7522 ND Enschede, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
11
|
|
12
|
Chng WJ, Tan GB, Kuperan P. Establishment of adult peripheral blood lymphocyte subset reference range for an Asian population by single-platform flow cytometry: influence of age, sex, and race and comparison with other published studies. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2004; 11:168-73. [PMID: 14715565 PMCID: PMC321350 DOI: 10.1128/cdli.11.1.168-173.2004] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2003] [Revised: 09/25/2003] [Accepted: 11/07/2003] [Indexed: 11/20/2022]
Abstract
We established a normal reference range for peripheral blood lymphocyte subsets in a multiracial adult population by using single-platform flow cytometry. Further analysis of our cohort showed that the CD8+-cell counts decrease with age, there is a gender difference in NK cell percentages and counts, and there are significant differences in the CD3+-, CD4+-, and CD19+-cell counts between Indians and other racial groups. Overall, our results are significantly different from other published data. This difference further stresses the need for different populations to establish their own reference ranges as these may have important implications for the management of patients with human immunodeficiency virus and AIDS. The use of single-platform flow cytometry will eliminate some of the variability between different study centers, making studies more comparable. This platform should be used for future studies into the effects of age, sex, and race on lymphocyte subsets.
Collapse
Affiliation(s)
- Wee J Chng
- Department of Haematology-Oncology, National University Hospital, Singapore, Republic of Singapore.
| | | | | |
Collapse
|
13
|
Janossy G, Jani IV, Bradley NJ, Bikoue A, Pitfield T, Glencross DK. Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2002; 9:1085-94. [PMID: 12204964 PMCID: PMC120051 DOI: 10.1128/cdli.9.5.1085-1094.2002] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2002] [Accepted: 04/22/2002] [Indexed: 11/20/2022]
Abstract
The flow cytometers that are currently supported by industry provide accurate CD4(+)-T-cell counts for monitoring human immunodeficiency virus disease but remain unaffordable for routine service work under resource-poor conditions. We therefore combined volumetric flow cytometry (measuring absolute lymphocyte counts in unit volumes of blood) and simpler protocols with generic monoclonal antibodies (MAbs) to increase cost efficiency. Volumetric absolute counts were generated using CD45/CD4 and CD45/CD8 MAb combinations in two parallel tubes. The percentage values for the various subsets were also determined within the leukocyte and lymphocyte populations utilizing a fully automated protocol. The levels of agreement between the newly developed method and the present industry standards, including both volumetric and bead-based systems using a full MAb panel for subset analysis, were tested by Bland-Altman analyses. The limits of agreement for CD4 counts generated by the volumetric methods using either CD45/CD4 (in a single tube) or the full Trio MAb panel (in three tubes) on the CytoronAbsolute flow cytometer were between -29 and +46 cells/mm(3) with very little bias for CD4 counts (in favor of the Trio method: +8 CD4(+) lymphocytes/mm(3); 0.38% of lymphocytes). The limits of agreement for absolute CD4 counts yielded by the volumetric CD45/CD4 method and the bead-based method were between -118 and +98 cells/mm(3), again with a negligible bias (-10 CD4(+) lymphocytes/mm(3)). In the volumetric method using CD45/CD8, the strongly CD8(+) cells were gated and the levels of agreement with the full Trio showed a minor bias (in favor of the Trio; +40 CD8(+) cells/mm(3); 5.2% of lymphocytes) without a significant influence on CD4/CD8 ratios. One trained flow cytometrist was able to process 300 to 400 stained tubes per day. This workload extrapolates to a throughput of >30,000 samples per year if both CD45/CD4 and CD45/CD8 stainings are performed for each patient or a throughput of >60,000 samples if only CD45/CD4 counts are tested in a single tube. Thus, on the basis of the high efficiency and excellent agreement with the present industry standards, volumetric flow cytometers with automated gating protocols and autobiosamplers, complemented by generic CD45, CD4, and CD8 MAbs used in two-color immunofluorescence, represent the most suitable arrangements for large regional laboratories in resource-poor settings.
Collapse
Affiliation(s)
- George Janossy
- HIV Immunology, Department of Immunology and Molecular Pathology, Royal Free and University College Medical School, London, United Kingdom.
| | | | | | | | | | | |
Collapse
|
14
|
Janossy G, Jani IV, Kahan M, Barnett D, Mandy F, Shapiro H. Precise CD4 T-cell counting using red diode laser excitation: for richer, for poorer. CYTOMETRY 2002; 50:78-85. [PMID: 12116349 DOI: 10.1002/cyto.10082] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Measuring CD4 T-cell counts at low cost is relevant in dealing with the human immunodeficiency virus (HIV) epidemic throughout the developing world. The recently introduced novel concepts in gating strategies and sample stabilization facilitate affordable immunophenotyping by flow cytometry. However, the impact of these developments is still limited by the high cost of currently available flow cytometers. METHODS Diode lasers emitting 10-15 mW at 635 nm are one-tenth the size and cost and require one thousandth the power of an equivalent 488-nm argon ion laser. We used the available 635-nm diode-based flow cytometers, including PA-II, Luminex 100, SuperMot, and FACSCalibur, to investigate whether these instruments can generate reliable CD4 counts when used with allophycocyanin (APC) and cyanin-5 (Cy5)-labeled CD4 antibodies. RESULTS We document the feasibility of obtaining leucocyte differential counts using orthogonal side scatter (SSC) without the need for forward scatter (FSC). Accurate CD4% values among lymphocytes and leucocytes can be obtained by primary CD4 gating using a single CD4 monoclonal antibody conjugated to APC or Cy5. Double immunofluorescence (IF) staining with CD4-APC (FL1) and CD45-APC-Cy7 (FL2) introduces pan-leucogating for a convenient assessment of absolute CD4 counts on double platforms. We demonstrate that small flow cytometers with laser diodes are capable of delivering absolute CD4 T-cell counts with a precision similar to the performance of the current state-of-the-art single-platform instruments (e.g., the CytoronAbsolute; R(2) = 0.961). In this respect, they appear to be superior to the nonflow CD4 counting techniques. CONCLUSIONS Accurate CD4 counts can be generated at minimal cost on red diode laser-operated flow cytometers, retaining the potential for high throughput capacity without compromising precision. With further improvements in volumetric technology and clinical software, these cytometers may develop into a new generation of inexpensive battery-operated laboratory hardware that combines cellular phenotyping with bead-based multiplexing immunoassays for (HIV) serology.
Collapse
Affiliation(s)
- George Janossy
- HIV Immunology, Department of Immunology and Molecular Pathology, Royal Free and University College Medical School, Rowland Street, London NW3 2PF, United Kingdom
| | | | | | | | | | | |
Collapse
|
15
|
Brando B, Barnett D, Janossy G, Mandy F, Autran B, Rothe G, Scarpati B, D'Avanzo G, D'Hautcourt JL, Lenkei R, Schmitz G, Kunkl A, Chianese R, Papa S, Gratama JW. Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. European Working Group on Clinical Cell Analysis. CYTOMETRY 2000; 42:327-46. [PMID: 11135287 DOI: 10.1002/1097-0320(20001215)42:6<327::aid-cyto1000>3.0.co;2-f] [Citation(s) in RCA: 178] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The enumeration of absolute levels of cells and their subsets in clinical samples is of primary importance in human immunodeficiency virus (HIV)+ individuals (CD4+ T- lymphocyte enumeration), in patients who are candidates for autotransplantation (CD34+ hematopoietic progenitor cells), and in evaluating leukoreduced blood products (residual white blood cells). These measurements share a number of technical options, namely, single- or multiple-color cell staining and logical gating strategies. These can be accomplished using single- or dual-platform counting technologies employing cytometric methods. Dual-platform counting technologies couple the percentage of positive cell subsets obtained by cytometry and the absolute cell count obtained by automated hematology analyzers to derive the absolute value of such subsets. Despite having many conceptual and technical limitations, this approach is traditionally considered as the reference method for absolute cell count enumeration. As a result, the development of single-platform technologies has recently attracted attention with several different technical approaches now being readily available. These single-platform approaches have less sources of variability. A number of reports clearly demonstrate that they provide better coefficients of variation (CVs) in multicenter studies and a lower chance to generate aberrant results. These methods are therefore candidates for the new gold standard for absolute cell assessments. The currently available technical options are discussed in this review together with the results of some cross-comparative studies. Each analytical system has its own specific requirements as far as the dispensing precision steps are concerned. The importance of precision reverse pipetting is emphasized. Issues still under development include the establishment of the critical error ranges, which are different in each test setting, and the applicability of simplified low-cost techniques to be used in countries with limited resources.
Collapse
Affiliation(s)
- B Brando
- Transplant Immunology and Hematology Laboratory, Niguarda-Ca' Granda Hospital, Milan, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
O'Gorman MR, Nicholson JK. Adoption of single-platform technologies for enumeration of absolute T-lymphocyte subsets in peripheral blood. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2000; 7:333-5. [PMID: 10799442 PMCID: PMC95875 DOI: 10.1128/cdli.7.3.333-335.2000] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- M R O'Gorman
- Department of Pediatrics, Northwestern University Medical School, and Diagnostic Immunology and Flow Cytometry Laboratories, Children's Memorial Hospital, Chicago, Illinois 60614, USA.
| | | |
Collapse
|
17
|
Schnizlein-Bick CT, Spritzler J, Wilkening CL, Nicholson JK, O'Gorman MR. Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Site Investigators and The NIAID DAIDS New Technologies Evaluation Group. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2000; 7:336-43. [PMID: 10799443 PMCID: PMC95876 DOI: 10.1128/cdli.7.3.336-343.2000] [Citation(s) in RCA: 99] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A single-platform technology that uses an internal bead standard and three-color flow cytometry to determine CD4 and CD8 absolute counts was evaluated for reproducibility and agreement. Values obtained using TruCount absolute-count tubes were compared to those obtained using a two-color predicate methodology. Sixty specimens from human immunodeficiency virus type 1-infected donors were shipped to five laboratories. Each site also analyzed replicates of 14 human immunodeficiency virus type 1-infected local specimens at 6 h and again at 24 h. The interlaboratory variability was significantly less with TruCount (median difference in percent coefficient of variation [%CV] between the two methods was -8% and -3% for CD4 and CD8, respectively) than with the predicate method. Intralaboratory variability was smaller, with a median difference in %CV of -1% for both CD4 and CD8 with 6-h samples and -2% and -3% for CD4 and CD8, respectively, with 24-h samples. Use of TruCount for shipped samples resulted in a median CD4 count change of 7 cells (50th estimated percentile) when all laboratories and CD4 strata were combined. For on-site samples, the median CD4 count change was 10 CD4 cells for 6-h samples and 2 CD4 cells for 24-h samples. Individual site biases occurred in both directions and cancelled each other when the data were combined for all laboratories. Thus, the combined data showed a smaller change in median CD4 count than what may have occurred at an individual site. In summary, the use of TruCount decreased both the inter- and intralaboratory variability in determining absolute CD4 and CD8 counts.
Collapse
Affiliation(s)
- C T Schnizlein-Bick
- Department of Medicine/Infectious Diseases, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.
| | | | | | | | | |
Collapse
|
18
|
Reimann KA, O'Gorman MR, Spritzler J, Wilkening CL, Sabath DE, Helm K, Campbell DE. Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2000; 7:344-51. [PMID: 10799444 PMCID: PMC95877 DOI: 10.1128/cdli.7.3.344-351.2000] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
New analytic methods that permit absolute CD4 and CD8 T-cell determinations to be performed entirely on the flow cytometer have the potential for improving assay precision and accuracy. In a multisite trial, we compared two different single-platform assay methods with a predicate two-color assay in which the absolute lymphocyte count was derived by conventional hematology. A two-color method employing lymphocyte light scatter gating and Beckman Coulter Flow-Count fluorospheres for absolute counting produced within-laboratory precision equivalent to that of the two-color predicate method, as measured by coefficient of variation of replicate measurements. The fully automated Beckman Coulter tetraONE System four-color assay employing CD45 lymphocyte gating, automated analysis, and absolute counting by fluorospheres resulted in a small but significant improvement in the within-laboratory precision of CD4 and CD8 cell counts and percentages suggesting that the CD45 lymphocyte gating and automated analysis might have contributed to the improved performance. Both the two-color method employing Flow-Count fluorospheres and the four-color tetraONE System provided significant and substantial improvements in between-laboratory precision of absolute counts. In some laboratories, absolute counts obtained by the single-platform methods showed small but consistent differences relative to the predicate method. Comparison of each laboratory's absolute counts with the five-laboratory median value suggested that these differences resulted from a bias in the absolute lymphocyte count obtained from the hematology instrument in some laboratories. These results demonstrate the potential for single-platform assay methods to improve within-laboratory and between-laboratory precision of CD4 and CD8 T-cell determinations compared with conventional assay methods.
Collapse
Affiliation(s)
- K A Reimann
- Division of Viral Pathogenesis, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA.
| | | | | | | | | | | | | |
Collapse
|
19
|
Brecher ME, Wong EC, Chen SE, Vampola C, Rocco RM. Antibiotic-labeled probes and microvolume fluorimetry for the rapid detection of bacterial contamination in platelet components: a preliminary report. Transfusion 2000; 40:411-3. [PMID: 10773051 DOI: 10.1046/j.1537-2995.2000.40040411.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Approximately 1 platelet in 2000 components is bacterially contaminated. Most commonly, contaminating organisms are gram positive skin saprophytes (such as Staphylococcus sp. or Bacillus sp.). A novel approach to the rapid diagnosis of gram positive contamination by the use of a fluorescence-labeled antibiotic probe with affinity for the gram positive cell was investigated. STUDY DESIGN AND METHODS Two isolates of Staphylococcus epidermidis were inoculated into bags of Day 0 platelets. Quantitative cultures along with a semi-automated screening assay on a microvolume fluorimeter employing a fluorescence-conjugated vancomycin probe was performed for each day of storage. In addition, serial dilutions of the bacteria were added to sterile platelets to achieve a range spanning 10(1) to 10(8) CFUs per mL. RESULTS All samples with a bacterial contamination of > or =10(5) CFU per mL were detected. Sterile samples were nonreactive. The entire procedure requires three pipetting steps and took less than 1 hour to perform. CONCLUSION These preliminary results with the use of fluorescence-labeled antibiotics as probes combined with microvolume fluorimetry for the rapid detection of bacterial contamination of platelet components suggest that this is a promising approach. Further studies with additional organisms and alternative conjugates, bacteria, and antibiotics are underway.
Collapse
Affiliation(s)
- M E Brecher
- University of North Carolina Hospitals, Chapel Hill, NC 27514, USA.
| | | | | | | | | |
Collapse
|
20
|
Prieto A, Reyes E, Diaz D, Hernandez-Fuentes MP, Monserrat J, Perucha E, Muñoz L, Vangioni R, de La Hera A, Orfao A, Alvarez-Mon M. A new method for the simultaneous analysis of growth and death of immunophenotypically defined cells in culture. CYTOMETRY 2000; 39:56-66. [PMID: 10655563 DOI: 10.1002/(sici)1097-0320(20000101)39:1<56::aid-cyto8>3.0.co;2-v] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Internal standards have been used in flow cytometry methods to enumerate lymphoid subsets and hemopoietic progenitor cells ex vivo. However, the currently available methods cannot be readily applied to the analysis of cultured cells because of the frequent occurrence of cell death during in vitro assays. METHODS This paper reports a new method for the enumeration of both viable and nonviable cells in culture. Cells were counted with the aid of an internal reference standard of microbeads, and live versus dead cell discrimination was performed using 7-amino-actinomycin D which allows the double staining of surface antigens. RESULTS The method is more precise, accurate and sensitive than either conventional light microscopy-based or automated cell counting. Additionally, it may be used to accurately measure the number of apoptotic cells in a culture. RESULTS Through the enumeration of surviving cells it is demonstrated that, when applied to the study of mitogen-activated T lymphocytes, current flow cytometry techniques (which do not use internal standards) for the study of the viability and apoptosis overestimate the fraction of viable cells and underestimate both the fraction of dead and apoptotic cells. CONCLUSIONS The new method overcomes these limitations and is of use in the in vitro study of cell growth and apoptosis.
Collapse
Affiliation(s)
- A Prieto
- Department of Medicine, University of Alcalá, Alcalá de Henares, Madrid, Spain
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Glencross D, Scott L, Aggett H, Sonday S, Scott CS. Microvolume fluorimetry for the determination of absolute CD4 and CD8 lymphocyte counts in patients with HIV: a comparative evaluation. CLINICAL AND LABORATORY HAEMATOLOGY 1999; 21:391-5. [PMID: 10671991 DOI: 10.1046/j.1365-2257.1999.00276.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
This study compared CD4 and CD8 lymphocyte counts obtained by microvolume fluorimetry (MVF) with those derived by flow cytometry (FC). Samples from 192 patients with known or suspected HIV were analysed, and the distribution of CD4 counts for these samples ranged from 0 and 1,279/microl, with 142/192 (74%) of the samples having CD4 values of less than 400/microl. Good agreement between FC and MVF CD4 counts was found (MVF = 0.98 x FC + 7.30) although there was a minor constant inter-method bias of approximately +7 cells/microl for the MVF data. For CD8 counts there was a constant bias between the two methods of approximately +23 cells/microl for FC. Most outliers were associated with higher FC CD8 counts. Supplementary analyses showed a high level of agreement between FC and MVF methods for the CD4:CD8 ratios (MVF = 0.98 x FC). This suggests that observed discrepancies between FC and MVF methods were almost certainly a result of the influence of the absolute lymphocyte counts obtained from the haematology analyser. The results confirm that the IMAGN 2000 microvolume fluorimeter system can be used as an alternative to conventional flow cytometry for the enumeration of CD4 and CD8 counts.
Collapse
Affiliation(s)
- D Glencross
- Department of Haematology, South African Institute for Medical Research, Johannesburg Hospital, Johannesburg, South Africa
| | | | | | | | | |
Collapse
|
22
|
Cabezudo E, Querol S, Cancelas JA, García J. Comparison of volumetric capillary cytometry with standard flow cytometry for routine enumeration of CD34+ cells. Transfusion 1999; 39:864-72. [PMID: 10504123 DOI: 10.1046/j.1537-2995.1999.39080864.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND This study assesses the feasibility of a new volumetric cytometry system for the enumeration of CD34+ cells in apheresis components, peripheral blood, and cord blood samples in routine laboratory work. This system is compared with the following flow cytometry protocols: Milan, ISHAGE, ISHAGE with 7-AAD, and flow-count fluorospheres. STUDY DESIGN AND METHODS Correlation, linearity, and reproducibility studies were performed for the various methods. Clonogenic cultures were performed, as an external control, to assess the correlation between the number of CD34+ cells per microL and the number of colony-forming units per microL. RESULTS The linear regression analysis demonstrated that the five methods were comparable (R2 ranged from 0.86 to 0.96 and slopes were close to 1). The CD34+ assay and the flow-count methods showed poor linearity for CD34+ cell counts below 10 cells per microL (R2 = 0.46 and 0.47). The reproducibility assay for a CD34+ count of 10 cells per microL showed a CV of 12 percent and 25 percent for the Milan and CD34+ assay methods, respectively. The mean CV among all five methods for the 46 evaluated samples was 20 percent. There was a strong correlation between the number of CD34+ cells per microL and colony-forming units per microL in cord blood and apheresis samples (r = 0.71-0.81). CONCLUSION The CD34+ assay is useful in CD34 enumeration in cord blood, leukapheresis samples, and peripheral blood samples and provides comparable results to the Milan, ISHAGE, ISHAGE with 7-AAD, and flow-count methods. Nevertheless, peripheral blood samples with low CD34 absolute counts (below 10 cells/microL) should be analyzed by alternative flow cytometry protocols. Even though the same operator performed the study in a single laboratory, the high inter-method CV suggests that differences in sample preparation and gating strategy are factors that increase variability. Protocols with fewer intermediate steps or fully automated protocols such as the CD34+ assay are expected to reduced intra- and inter-laboratory variability.
Collapse
Affiliation(s)
- E Cabezudo
- Department of Criobiology and Cell Therapy, Cancer Research Institute, Duran i Reynals Hospital, Barcelona, Spain.
| | | | | | | |
Collapse
|