1
|
Martens J, Panzer S, den Wijngaard J, Siebes M, Schreiber LM. Influence of contrast agent dispersion on bolus‐based MRI myocardial perfusion measurements: A computational fluid dynamics study. Magn Reson Med 2019; 84:467-483. [DOI: 10.1002/mrm.28125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 11/19/2019] [Accepted: 11/20/2019] [Indexed: 12/22/2022]
Affiliation(s)
- Johannes Martens
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| | - Sabine Panzer
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| | - Jeroen den Wijngaard
- Department of Biomedical Engineering & Physics Amsterdam University Medical Center University of Amsterdam Amsterdam Cardiovascular Sciences Amsterdam Netherlands
- Department of Clinical Chemistry and Hematology Diakonessenhuis Utrecht Netherlands
| | - Maria Siebes
- Department of Biomedical Engineering & Physics Amsterdam University Medical Center University of Amsterdam Amsterdam Cardiovascular Sciences Amsterdam Netherlands
| | - Laura M. Schreiber
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure CenterUniversity Hospitals Würzburg Germany
- Department of Cardiovascular Imaging Comprehensive Heart Failure Center University Hospitals Würzburg Germany
| |
Collapse
|
2
|
Hoffman JIE. The history of the microsphere method for measuring blood flows with special reference to myocardial blood flow: a personal memoir. Am J Physiol Heart Circ Physiol 2017; 312:H705-H710. [PMID: 28130341 DOI: 10.1152/ajpheart.00834.2016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 01/09/2017] [Accepted: 01/19/2017] [Indexed: 11/22/2022]
Abstract
We use many types of equipment and technologies to make our measurements but give little thought to how they developed. Evolution was once described as a series of recoils from blind alleys, and this is exemplified by the gradual development of the microsphere method of measuring blood flows. The microsphere method is one of the most frequently used methods for measuring blood flow to organs and portions of organs. The method can measure myocardial blood flow with reasonable accuracy (within 10%) down to samples weighing >50 mg but probably will not do so for samples weighing 1-10 mg. Microspheres with diameters from 10 to 15 μm provide the best compromise between accurate flow measurement and retention in tissue. Radioactive labels have been almst entirely replaced by fluorescent labels, but colored microspheres and neutron-activated labels are also used.NEW & NOTEWORTHY The contributions of the various individuals who developed the microsphere method of measuring regional blood flows and how these advances took place are brought to light in this paper.
Collapse
Affiliation(s)
- Julien I E Hoffman
- Department of Pediatrics, University of California, San Francisco, California
| |
Collapse
|
3
|
Sinclair MD, Lee J, Cookson AN, Rivolo S, Hyde ER, Smith NP. Measurement and modeling of coronary blood flow. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2015; 7:335-56. [PMID: 26123867 DOI: 10.1002/wsbm.1309] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Revised: 05/19/2015] [Accepted: 05/21/2015] [Indexed: 01/10/2023]
Abstract
Ischemic heart disease that comprises both coronary artery disease and microvascular disease is the single greatest cause of death globally. In this context, enhancing our understanding of the interaction of coronary structure and function is not only fundamental for advancing basic physiology but also crucial for identifying new targets for treating these diseases. A central challenge for understanding coronary blood flow is that coronary structure and function exhibit different behaviors across a range of spatial and temporal scales. While experimental studies have sought to understand this feature by isolating specific mechanisms, in tandem, computational modeling is increasingly also providing a unique framework to integrate mechanistic behaviors across different scales. In addition, clinical methods for assessing coronary disease severity are continuously being informed and updated by findings in basic physiology. Coupling these technologies, computational modeling of the coronary circulation is emerging as a bridge between the experimental and clinical domains, providing a framework to integrate imaging and measurements from multiple sources with mathematical descriptions of governing physical laws. State-of-the-art computational modeling is being used to combine mechanistic models with data to provide new insight into coronary physiology, optimization of medical technologies, and new applications to guide clinical practice.
Collapse
Affiliation(s)
- Matthew D Sinclair
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK
| | - Jack Lee
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK
| | - Andrew N Cookson
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK
| | - Simone Rivolo
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK
| | - Eoin R Hyde
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK
| | - Nicolas P Smith
- Division of Imaging Sciences and Biomedical Engineering, British Heart Foundation (BHF) Centre of Excellence, King's College London, London, UK.,Department of Engineering, University of Auckland, Auckland, New Zealand
| |
Collapse
|
4
|
Sinclair M, Lee J, Schuster A, Chiribiri A, van den Wijngaard J, van Horssen P, Siebes M, Spaan JAE, Nagel E, Smith NP. Microsphere skimming in the porcine coronary arteries: Implications for flow quantification. Microvasc Res 2015; 100:59-70. [PMID: 25963318 DOI: 10.1016/j.mvr.2015.04.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Revised: 03/28/2015] [Accepted: 04/17/2015] [Indexed: 11/25/2022]
Abstract
Particle skimming is a phenomenon where particles suspended in fluid flowing through vessels distribute disproportionately to bulk fluid volume at junctions. Microspheres are considered a gold standard of intra-organ perfusion measurements and are used widely in studies of flow distribution and quantification. It has previously been hypothesised that skimming at arterial junctions is responsible for a systematic over-estimation of myocardial perfusion from microspheres at the subendocardium. Our objective is to integrate coronary arterial structure and microsphere distribution, imaged at high resolution, to test the hypothesis of microsphere skimming in a porcine left coronary arterial (LCA) network. A detailed network was reconstructed from cryomicrotome imaging data and a Poiseuille flow model was used to simulate flow. A statistical approach using Clopper-Pearson confidence intervals was applied to determine the prevalence of skimming at bifurcations in the LCA. Results reveal that microsphere skimming is most prevalent at bifurcations in the larger coronary arteries, namely the epicardial and transmural arteries. Bifurcations at which skimming was identified have significantly more asymmetric branching parameters. This finding suggests that when using thin transmural segments to quantify flow from microspheres, a skimming-related deposition bias may result in underestimation of perfusion in the subepicardium, and overestimation in the subendocardium.
Collapse
Affiliation(s)
- Matthew Sinclair
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK
| | - Jack Lee
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK
| | - Andreas Schuster
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK; Department of Cardiology and Pneumology, Georg-August-University, Göttingen, Germany; German Centre for Cardiovascular Research (DZHK, Partner Site Göttingen), Göttingen, Germany
| | - Amedeo Chiribiri
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK
| | - Jeroen van den Wijngaard
- Department of Biomedical Engineering & Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Pepijn van Horssen
- Department of Biomedical Engineering & Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Maria Siebes
- Department of Biomedical Engineering & Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Jos A E Spaan
- Department of Biomedical Engineering & Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Eike Nagel
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK
| | - Nicolas P Smith
- Division of Imaging Sciences and Biomedical Engineering, King's College London, British Heart Foundation (BHF) Centre of Excellence, UK; National Institute of Heath Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Lambeth Wing, St. Thomas' Hospital, UK; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, Lambeth Wing, St. Thomas' Hospital, London, UK; Department of Engineering, University of Auckland, Auckland, New Zealand.
| |
Collapse
|
5
|
Schuster A, Sinclair M, Zarinabad N, Ishida M, van den Wijngaard JPHM, Paul M, van Horssen P, Hussain ST, Perera D, Schaeffter T, Spaan JAE, Siebes M, Nagel E, Chiribiri A. A quantitative high resolution voxel-wise assessment of myocardial blood flow from contrast-enhanced first-pass magnetic resonance perfusion imaging: microsphere validation in a magnetic resonance compatible free beating explanted pig heart model. Eur Heart J Cardiovasc Imaging 2015; 16:1082-92. [PMID: 25812572 DOI: 10.1093/ehjci/jev023] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 01/30/2015] [Indexed: 11/13/2022] Open
Abstract
AIMS To assess the feasibility of high-resolution quantitative cardiovascular magnetic resonance (CMR) voxel-wise perfusion imaging using clinical 1.5 and 3 T sequences and to validate it using fluorescently labelled microspheres in combination with a state of the art imaging cryomicrotome in a novel, isolated blood-perfused MR-compatible free beating pig heart model without respiratory motion. METHODS AND RESULTS MR perfusion imaging was performed in pig hearts at 1.5 (n = 4) and 3 T (n = 4). Images were acquired at physiological flow ('rest'), reduced flow ('ischaemia'), and during adenosine-induced hyperaemia ('stress') in control and coronary occlusion conditions. Fluorescently labelled microspheres and known coronary myocardial blood flow represented the reference standards for quantitative perfusion validation. For the comparison with microspheres, the LV was divided into 48 segments based on a subdivision of the 16 AHA segments into subendocardial, midmyocardial, and subepicardial subsegments. Perfusion quantification of the time-signal intensity curves was performed using a Fermi function deconvolution. High-resolution quantitative voxel-wise perfusion assessment was able to distinguish between occluded and remote myocardium (P < 0.001) and between rest, ischaemia, and stress perfusion conditions at 1.5 T (P < 0.001) and at 3 T (P < 0.001). CMR-MBF estimates correlated well with the microspheres at the AHA segmental level at 1.5 T (r = 0.94, P < 0.001) and at 3 T (r = 0.96, P < 0.001) and at the subendocardial, midmyocardial, and subepicardial level at 1.5 T (r = 0.93, r = 0.9, r = 0.88, P < 0.001, respectively) and at 3 T (r = 0.91, r = 0.95, r = 0.84, P < 0.001, respectively). CONCLUSION CMR-derived voxel-wise quantitative blood flow assessment is feasible and very accurate compared with microspheres. This technique is suitable for both clinically used field strengths and may provide the tools to assess extent and severity of myocardial ischaemia.
Collapse
Affiliation(s)
- Andreas Schuster
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK Department of Cardiology and Pneumology and German Centre for Cardiovascular Research (DZHK, Partner Site Göttingen), Georg-August-University, Göttingen, Germany
| | - Matthew Sinclair
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | - Niloufar Zarinabad
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | - Masaki Ishida
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | | | - Matthias Paul
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | - Pepijn van Horssen
- Department of Biomedical Engineering and Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Shazia T Hussain
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | - Divaka Perera
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK King's College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Department of Cardiology, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - Tobias Schaeffter
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| | - Jos A E Spaan
- Department of Biomedical Engineering and Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Maria Siebes
- Department of Biomedical Engineering and Physics, Academic Medical Centre, Amsterdam, The Netherlands
| | - Eike Nagel
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK Division of Cardiovascular Imaging, Goethe University Frankfurt and German Centre for Cardiovascular Research (DZHK, Partner Site Rhine-Main), Frankfurt, Germany
| | - Amedeo Chiribiri
- Division of Imaging Sciences and Biomedical Engineering, King's College London British Heart Foundation (BHF) Centre of Excellence, National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre, The Rayne Institute, St. Thomas' Hospital, Lambeth Palace Road, London, UK
| |
Collapse
|
6
|
Hakimzadeh N, van Horssen P, van Lier MGJTB, van den Wijngaard JPHM, Belterman C, Coronel R, Piek JJ, Verberne HJ, Spaan JAE, Siebes M. Detection and quantification methods of monocyte homing in coronary vasculature with an imaging cryomicrotome. J Mol Cell Cardiol 2014; 76:196-204. [PMID: 25179912 DOI: 10.1016/j.yjmcc.2014.08.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 08/07/2014] [Accepted: 08/25/2014] [Indexed: 11/18/2022]
Abstract
Cellular imaging modalities are important for revealing the behavior and role of monocytes in response to neovascularization progression in coronary artery disease. In this study we aimed to develop methods for high-resolution three-dimensional (3D) imaging and quantification of monocytes relative to the entire coronary artery network using a novel episcopic imaging modality. In a series of ex vivo experiments, human umbilical vein endothelial cells and CD14+ monocytes were labeled with fluorescent live cell tracker probes and infused into the coronary artery network of excised rat hearts by a Langendorff perfusion method. Coronary arteries were subsequently infused with fluorescent vascular cast material and processed with an imaging cryomicrotome, whereby each heart was consecutively cut (5 μm slice thickness) and block face imaged at appropriate excitation and emission wavelengths. The resulting image stacks yielded 3D reconstructions of the vascular network and the location of cells administered. Successful detection and quantification of single cells and cell clusters were achieved relative to the coronary network using customized particle detection software. These methods were then applied to an in vivo rabbit model of chronic myocardial ischemia in which autologous monocytes were isolated from peripheral blood, labeled with a fluorescent live cell tracker probe and re-infused into the host animal. The processed 3D image stacks revealed homing of monocytes to the ischemic myocardial tissue. Monocytes detected in the ischemic tissue were predominantly concentrated in the mid-myocardium. Vessel segmentation identified coronary collateral connections relative to monocyte localization. This study established a novel imaging platform to efficiently determine the localization of monocytes in relation to the coronary microvascular network. These techniques are invaluable for investigating the role of monocyte populations in the progression of coronary neovascularization in animal models of chronic and sub-acute myocardial ischemia.
Collapse
Affiliation(s)
- Nazanin Hakimzadeh
- Dept. of Biomedical Engineering & Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Pepijn van Horssen
- Dept. of Experimental Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Monique G J T B van Lier
- Dept. of Biomedical Engineering & Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | | | - Charly Belterman
- Dept. of Experimental Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Ruben Coronel
- Dept. of Experimental Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Jan J Piek
- Dept. of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Hein J Verberne
- Dept. of Nuclear Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Jos A E Spaan
- Dept. of Biomedical Engineering & Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Maria Siebes
- Dept. of Biomedical Engineering & Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
| |
Collapse
|
7
|
van Nierop BJ, Coolen BF, Bax NA, Dijk WJR, van Deel ED, Duncker DJ, Nicolay K, Strijkers GJ. Myocardial perfusion MRI shows impaired perfusion of the mouse hypertrophic left ventricle. Int J Cardiovasc Imaging 2014; 30:619-28. [DOI: 10.1007/s10554-014-0369-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 01/15/2014] [Indexed: 10/25/2022]
|
8
|
Beierwaltes WH, Harrison-Bernard LM, Sullivan JC, Mattson DL. Assessment of renal function; clearance, the renal microcirculation, renal blood flow, and metabolic balance. Compr Physiol 2013; 3:165-200. [PMID: 23720284 DOI: 10.1002/cphy.c120008] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Historically, tools to assess renal function have been developed to investigate the physiology of the kidney in an experimental setting, and certain of these techniques have utility in evaluating renal function in the clinical setting. The following work will survey a spectrum of these tools, their applications and limitations in four general sections. The first is clearance, including evaluation of exogenous and endogenous markers for determining glomerular filtration rate, the adaptation of estimated glomerular filtration rate in the clinical arena, and additional clearance techniques to assess various other parameters of renal function. The second section deals with in vivo and in vitro approaches to the study of the renal microvasculature. This section surveys a number of experimental techniques including corticotomy, the hydronephrotic kidney, vascular casting, intravital charge coupled device videomicroscopy, multiphoton fluorescent microscopy, synchrotron-based angiography, laser speckle contrast imaging, isolated renal microvessels, and the perfused juxtamedullary nephron microvasculature. The third section addresses in vivo and in vitro approaches to the study of renal blood flow. These include ultrasonic flowmetry, laser-Doppler flowmetry, magnetic resonance imaging (MRI), phase contrast MRI, cine phase contrast MRI, dynamic contrast-enhanced MRI, blood oxygen level dependent MRI, arterial spin labeling MRI, x-ray computed tomography, and positron emission tomography. The final section addresses the methodologies of metabolic balance studies. These are described for humans, large experimental animals as well as for rodents. Overall, the various in vitro and in vivo topics and applications to evaluate renal function should provide a guide for the investigator or physician to understand and to implement the techniques in the laboratory or clinic setting.
Collapse
Affiliation(s)
- William H Beierwaltes
- Hypertension and Vascular Research Division, Department of Internal Medicine, Henry Ford Hospital, and Department of Physiology, Wayne State University School of Medicine, Detroit, Michigan, USA.
| | | | | | | |
Collapse
|
9
|
Jogiya R, Makowski M, Phinikaridou A, Patel AS, Jansen C, Zarinabad N, Chiribiri A, Botnar R, Nagel E, Kozerke S, Plein S. Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres. J Cardiovasc Magn Reson 2013; 15:62. [PMID: 23870734 PMCID: PMC3750232 DOI: 10.1186/1532-429x-15-62] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Accepted: 07/07/2013] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Dynamic first pass contrast-enhanced myocardial perfusion is the standard CMR method for the estimation of myocardial blood flow (MBF) and MBF reserve in man, but it is challenging in rodents because of the high temporal and spatial resolution requirements. Hyperemic first pass myocardial perfusion CMR during vasodilator stress in mice has not been reported. METHODS Five C57BL/6 J mice were scanned on a clinical 3.0 Tesla Achieva system (Philips Healthcare, Netherlands). Vasodilator stress was induced via a tail vein catheter with an injection of dipyridamole. Dynamic contrast-enhanced perfusion imaging (Gadobutrol 0.1 mmol/kg) was based on a saturation recovery spoiled gradient echo method with 10-fold k-space and time domain undersampling (k-t PCA). One week later the mice underwent repeat anaesthesia and LV injections of fluorescent microspheres at rest and at stress. Microspheres were analysed using confocal microscopy and fluorescence-activated cell sorting. RESULTS Mean MBF at rest measured by Fermi-function constrained deconvolution was 4.1 ± 0.5 ml/g/min and increased to 9.6 ± 2.5 ml/g/min during dipyridamole stress (P = 0.005). The myocardial perfusion reserve was 2.4 ± 0.54. The mean count ratio of stress to rest microspheres was 2.4 ± 0.51 using confocal microscopy and 2.6 ± 0.46 using fluorescence. There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84). CONCLUSION First-pass myocardial stress perfusion CMR in a mouse model is feasible at 3 Tesla. Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis. Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.
Collapse
Affiliation(s)
- Roy Jogiya
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Markus Makowski
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Alkystsis Phinikaridou
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Ashish S Patel
- Academic Department of Surgery, Cardiovascular Division, BHF Centre of Excellence, Kings College, London, UK
| | - Christian Jansen
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Niloufar Zarinabad
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Amedeo Chiribiri
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Rene Botnar
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Eike Nagel
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
| | - Sebastian Kozerke
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Sven Plein
- King’s College London BHF Centre of Excellence, NIHR Biomedical Research Centre and Welcome Trust and EPSRC Medical Engineering Centre at Guy’s and St. Thomas’ NHS Foundation Trust, Division of Imaging Sciences, The Rayne Institute, London, UK
- Multidisciplinary Cardiovascular Research Centre & Leeds Institute of Genetics, Health and Therapeutics, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
10
|
van den Wijngaard JPHM, Schwarz JCV, van Horssen P, van Lier MGJTB, Dobbe JGG, Spaan JAE, Siebes M. 3D Imaging of vascular networks for biophysical modeling of perfusion distribution within the heart. J Biomech 2012; 46:229-39. [PMID: 23237670 DOI: 10.1016/j.jbiomech.2012.11.027] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2012] [Accepted: 11/09/2012] [Indexed: 02/07/2023]
Abstract
One of the main determinants of perfusion distribution within an organ is the structure of its vascular network. Past studies were based on angiography or corrosion casting and lacked quantitative three dimensional, 3D, representation. Based on branching rules and other properties derived from such imaging, 3D vascular tree models were generated which were rather useful for generating and testing hypotheses on perfusion distribution in organs. Progress in advanced computational models for prediction of perfusion distribution has raised the need for more realistic representations of vascular trees with higher resolution. This paper presents an overview of the different methods developed over time for imaging and modeling the structure of vascular networks and perfusion distribution, with a focus on the heart. The strengths and limitations of these different techniques are discussed. Episcopic fluorescent imaging using a cryomicrotome is presently being developed in different laboratories. This technique is discussed in more detail, since it provides high-resolution 3D structural information that is important for the development and validation of biophysical models but also for studying the adaptations of vascular networks to diseases. An added advantage of this method being is the ability to measure local tissue perfusion. Clinically, indices for patient-specific coronary stenosis evaluation derived from vascular networks have been proposed and high-resolution noninvasive methods for perfusion distribution are in development. All these techniques depend on a proper representation of the relevant vascular network structures.
Collapse
Affiliation(s)
- Jeroen P H M van den Wijngaard
- Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
11
|
van Nierop BJ, Coolen BF, Dijk WJ, Hendriks AD, de Graaf L, Nicolay K, Strijkers GJ. Quantitative first-pass perfusion MRI of the mouse myocardium. Magn Reson Med 2012; 69:1735-44. [DOI: 10.1002/mrm.24424] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2012] [Revised: 06/11/2012] [Accepted: 06/27/2012] [Indexed: 01/05/2023]
|
12
|
Hsu LY, Groves DW, Aletras AH, Kellman P, Arai AE. A quantitative pixel-wise measurement of myocardial blood flow by contrast-enhanced first-pass CMR perfusion imaging: microsphere validation in dogs and feasibility study in humans. JACC Cardiovasc Imaging 2012; 5:154-66. [PMID: 22340821 DOI: 10.1016/j.jcmg.2011.07.013] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Revised: 07/18/2011] [Accepted: 07/21/2011] [Indexed: 12/31/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate fully quantitative myocardial blood flow (MBF) at a pixel level based on contrast-enhanced first-pass cardiac magnetic resonance (CMR) imaging in dogs and in patients. BACKGROUND Microspheres can quantify MBF in subgram regions of interest, but CMR perfusion imaging may be able to quantify MBF and differentiate blood flow at a much higher resolution. METHODS First-pass CMR perfusion imaging was performed in a dog model with local hyperemia induced by intracoronary adenosine. Fluorescent microspheres were the reference standard for MBF validation. CMR perfusion imaging was also performed on patients with significant coronary artery disease (CAD) by invasive coronary angiography. Myocardial time-signal intensity curves of the images were quantified on a pixel-by-pixel basis using a model-constrained deconvolution analysis. RESULTS Qualitatively, color CMR perfusion pixel maps were comparable to microsphere MBF bull's-eye plots in all animals. Pixel-wise CMR MBF estimates correlated well against subgram (0.49 ± 0.14 g) microsphere measurements (r = 0.87 to 0.90) but showed minor underestimation of MBF. To reduce bias due to misregistration and minimize issues related to repeated measures, 1 hyperemic and 1 remote sector per animal were compared with the microsphere MBF, which improved the correlation (r = 0.97 to 0.98), and the bias was close to zero. Sector-wise and pixel-wise CMR MBF estimates also correlated well (r = 0.97). In patients, color CMR stress perfusion pixel maps showed regional blood flow decreases and transmural perfusion gradients in territories served by stenotic coronary arteries. MBF estimates in endocardial versus epicardial subsectors, and ischemic versus remote sectors, were all significantly different (p < 0.001 and p < 0.01, respectively). CONCLUSIONS Myocardial blood flow can be quantified at the pixel level (∼32 μl of myocardium) on CMR perfusion images, and results compared well with microsphere measurements. High-resolution pixel-wise CMR perfusion maps can quantify transmural perfusion gradients in patients with CAD.
Collapse
Affiliation(s)
- Li-Yueh Hsu
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Department of Health and Human Services, Bethesda, Maryland 20892-1061, USA
| | | | | | | | | |
Collapse
|
13
|
Animal Models in Cardiovascular MRI Research: Value and Limitations. CURRENT CARDIOVASCULAR IMAGING REPORTS 2012. [DOI: 10.1007/s12410-012-9128-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
14
|
Botnar RM, Makowski MR. Cardiovascular magnetic resonance imaging in small animals. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2012; 105:227-61. [PMID: 22137434 DOI: 10.1016/b978-0-12-394596-9.00008-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Noninvasive imaging studies involving small animals are becoming increasingly important in preclinical pharmacological, genetic, and biomedical cardiovascular research. Especially small animal magnetic resonance imaging (MRI) using high field and clinical MRI systems has gained significant importance in recent years. Compared to other imaging modalities, like computer tomography, MRI can provide an excellent soft tissue contrast, which enables the characterization of different kinds of tissues without the use of contrast agents. In addition, imaging can be performed with high spatial and temporal resolution. Small animal MRI cannot only provide anatomical information about the beating murine heart; it can also provide functional and molecular information, which makes it a unique imaging modality. Compared to clinical MRI examinations in humans, small animal MRI is associated with additional challenges. These included a smaller size of all cardiovascular structures and a up to ten times higher heart rate. Dedicated small animal monitoring devices make a reliable cardiac triggering and respiratory gating feasible. MRI in combination with molecular probes enables the noninvasive imaging of biological processes at a molecular level. Different kinds of iron oxide or gadolinium-based contrast agents can be used for this purpose. Compared to other molecular imaging modalities, like single photon emission computed tomography (SPECT) and positron emission tomography (PET), MRI can also provide imaging with high spatial resolution, which is of high importance for the assessment of the cardiovascular system. The sensitivity for detection of MRI contrast agents is however lower compared to sensitivity of radiation associated techniques like PET and SPECT. This chapter is divided into the following sections: (1) "Introduction," (2) "Principals of Magnetic Resonance Imaging," (3) "MRI Systems for Preclinical Imaging and Experimental Setup," and (4) "Cardiovascular Magnetic Resonance Imaging."
Collapse
Affiliation(s)
- René M Botnar
- Division of Imaging Sciences, King's College London, London, United Kingdom
| | | |
Collapse
|
15
|
Munch G, McKay S, Gussakovsky E, Kuzio B, Kupriyanov VV, Jilkina O. Rhodamine 800 as a near-infrared fluorescent deposition flow tracer in rodent hearts. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:065001. [PMID: 21721801 DOI: 10.1117/1.3583581] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We investigated the use of a near-infrared (NIR) fluorescent dye, Rhodamine 800 (Rhod800, λ(exc) = 693 nm, λ(em) > 720 nm) as a flow-dependent molecular tracer for NIR spectroscopy and high-resolution cardiac imaging. Rhod800 accumulates in isolated mitochondria in proportion to the mitochondrial membrane potential (ΔΨ). However, in the intact myocardium, Rhod800 binding is ΔΨ-independent. Rat hearts were perfused in a Langendorff mode with Krebs-Henseleit buffer containing 45-nM Rhod800 at normal (100%), increased (150%), or reduced (50%) baseline coronary flow (CF) per gram, for 30 to 60 min. In a different group of hearts, the left anterior descending artery (LAD) was occluded prior to Rhod800 infusion to create a flow deficit area. Rhod800 deposition was analyzed by: 1. absorbance spectroscopy kinetics in the Rhod800-perfused hearts, 2. Rhod800 absorbance and fluorescence imaging in the short-axis heart slices, and 3. dynamic epicardial/subepicardial fluorescence imaging of Rhod800 in KCl-arrested hearts, with a spatial resolution of ∼ 200 μm. Rhod800 deposition was proportional to the perfusate volume (CF and perfusion time) and there was no Rhod800 loss during the washout period. In the LAD-ligated hearts, Rhod800 fluorescence was missing from the no-flow, LAD-dependent endocardial and epicardial/subepicardial area. We concluded that Rhod800 can be used as a deposition flow tracer for dynamic cardiac imaging.
Collapse
Affiliation(s)
- Garret Munch
- University of Manitoba, Department of Chemistry, Winnipeg, Manitoba, R3T 2N2, Canada
| | | | | | | | | | | |
Collapse
|
16
|
Gussakovsky E, Kuzio B, Yang Y, Kupriyanov V. Fluorescence imaging to quantify the fluorescent microspheres in cardiac tissue. JOURNAL OF BIOPHOTONICS 2011; 4:277-287. [PMID: 20672303 DOI: 10.1002/jbio.201000057] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
To quantify the fluorescent microsphere (FM) content in cardiac tissue, which is an indicative of blood flow, fluorescence imaging of both sides of the pig heart slice was employed. Despite the light scattering inside the tissue and contributions from multiple tissue layers to the total emission, it is shown that the fluorescence intensity at any pixel is proportional to the FM content and the fluorescence image may be transformed to the image of the FM concentration. A convenient standard for the emission-FM concentration transformation is proposed. The approach has several advantages in comparison with the traditional "digestion & extraction" method such as: non-destructiveness, high spatial resolution, high throughput, repeatability and simplicity of operation.
Collapse
Affiliation(s)
- Eugene Gussakovsky
- National Research Council Institute for Biodiagnostics, Winnipeg, Manitoba R3B1Y6 Canada.
| | | | | | | |
Collapse
|
17
|
Improved detection of fluorescently labeled microspheres and vessel architecture with an imaging cryomicrotome. Med Biol Eng Comput 2010; 48:735-44. [PMID: 20574721 PMCID: PMC2903706 DOI: 10.1007/s11517-010-0652-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Accepted: 06/06/2010] [Indexed: 12/27/2022]
Abstract
Due to spectral overlap, the number of fluorescent labels for imaging cryomicrotome detection was limited to 4. The aim of this study was to increase the separation of fluorescent labels. In the new imaging cryomicrotome, the sample is cut in slices of 40 μm. Six images are taken for each cutting plane. Correction for spectral overlap is based on linear combinations of fluorescent images. Locations of microspheres are determined by using the system point spread function. Five differently colored microspheres were injected in vivo distributed over two major coronaries, the left anterior descending and left circumflex artery. Under absence of collateral flow, microspheres outside of target perfusion territories were not found and the procedure did not generate false positive detection when spectral overlap was relevant. In silico-generated microspheres were used to test the effect of background image, transparency correction, and color separation. The percentage of microspheres undetected was 2.3 ± 0.8% in the presence and 1.5 ± 0.4% in the absence of background structures with a density of 900 microspheres per color per cm3. The image analysis method presented here, allows for an increased number of experimental conditions that can be investigated in studies of regional myocardial perfusion.
Collapse
|
18
|
Makowski MR, Wiethoff AJ, Jansen CHP, Botnar RM. Cardiovascular MRI in small animals. Expert Rev Cardiovasc Ther 2010; 8:35-47. [PMID: 20014933 DOI: 10.1586/erc.09.126] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Imaging studies of cardiovascular disease in small rodents have become a prerequisite in preclinical cardiovascular research. Transgenic and gene-knockout models of cardiovascular diseases enables the investigation of the influence of single genes or groups of genes on disease pathogenesis. In addition, experimental and genetically altered models provide valuable in vivo platforms to investigate the efficacy of novel drugs and contrast agents. Owing to the excellent soft tissue contrast, high spatial and temporal resolution, as well as the tomographic nature of MRI, anatomy and function can be assessed with unique accuracy and reproducibility. Furthermore, using novel targeted MRI contrast agents, molecular changes associated with cardiovascular disease can be investigated in the same imaging session. This review focuses on recent advances in hardware, imaging sequences and probe design.
Collapse
Affiliation(s)
- Marcus R Makowski
- Division of Imaging Sciences, King's College London, 4th Floor, Lambeth Wing, St Thomas' Hospital, London SE1 7EH, UK.
| | | | | | | |
Collapse
|
19
|
On the Emission Intensity of Fluorescent Microspheres in Cardiac Tissue Images. J Fluoresc 2010; 20:857-63. [DOI: 10.1007/s10895-010-0629-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2009] [Accepted: 02/08/2010] [Indexed: 10/19/2022]
|
20
|
In Vivo T2-Weighted Magnetic Resonance Imaging Can Accurately Determine the Ischemic Area at Risk for 2-Day-Old Nonreperfused Myocardial Infarction. Invest Radiol 2008; 43:7-15. [DOI: 10.1097/rli.0b013e3181558822] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
21
|
Abstract
Transgenic and knockout mice can be used to study the genes and basic mechanisms involved in heart disease, and have therefore assumed a central role in modern cardiac research. MRI and MRS techniques have recently been developed for mice that enable the quantitative or semi-quantitative in vivo assessment of cardiac anatomy, function, perfusion, infarction, Ca(2+) influx, and metabolism. With these techniques, the normal mouse heart has been shown to be well suited as a model of human cardiac disease. The roles of individual genes in normal cardiac physiology have recently been studied by MR, including the role of neuronal nitric oxide synthase in beta-adrenergic stimulation, the roles of the inducible nitric oxide synthase and myoglobin in function, dilation, and energetics, and the role of cardiac troponin I in contractility. Furthermore, with a mouse model of myocardial infarction, the roles of the angiotensin II type 2 receptor, xanthine oxidase inhibitors, blood coagulation factor XIII, and inducible nitric oxide synthase in post-infarct function and remodeling have been further elucidated. Non-invasive in vivo MRI and MRS in mice provide a unique and powerful means for phenotyping genetically engineered mice and can improve our understanding of the roles of specific genes and proteins in cardiac physiology and pathophysiology.
Collapse
Affiliation(s)
- Frederick H Epstein
- Departments of Radiology and Biomedical Engineering, and the Cardiovascular Research Center, University of Virginia, Charlottesville, VA 22908, USA.
| |
Collapse
|
22
|
Marsh RL, Ellerby DJ. Partitioning locomotor energy use among and within muscles Muscle blood flow as a measure of muscle oxygen consumption. J Exp Biol 2006; 209:2385-94. [PMID: 16788022 DOI: 10.1242/jeb.02287] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
SUMMARYLinking the mechanics and energetics of locomotion in vertebrates has been hampered by a lack of information regarding the energy use of individual skeletal muscles in vivo. Here, we present a review of the available data concerning the relationship between the rates of skeletal muscle blood flow and oxygen consumption(V̇O2). In active muscle, during aerobically supported exercise, there is a linear relationship between these variables, irrespective of the muscle fiber type and intensity of exercise through most of the aerobic exercise range. We conclude that the rate of blood flow is the best available indicator of aerobic metabolic rate in multiple individual muscles or regions of muscles during locomotion. The practical considerations of using the injectable microsphere technique to measure muscle blood flow in this context are discussed.
Collapse
Affiliation(s)
- Richard L Marsh
- Department of Biology, Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA.
| | | |
Collapse
|
23
|
Marxen M, Sled JG, Yu LX, Paget C, Henkelman RM. Comparing microsphere deposition and flow modeling in 3D vascular trees. Am J Physiol Heart Circ Physiol 2006; 291:H2136-41. [PMID: 16766647 DOI: 10.1152/ajpheart.00146.2006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Blood perfusion in organs has been shown to be heterogeneous in a number of cases. At the same time, a number of models of vascular structure and flow have been proposed that also generate heterogeneous perfusion. Although a relationship between local perfusion and vascular structure has to exist, no model has yet been validated as an accurate description of this relationship. A study of perfusion and three-dimensional (3D) arterial structure in individual rat kidneys is presented, which allows comparison between local measurements of perfusion and model-based predictions. High-resolution computed tomography is used to obtain images of both deposited microspheres and of an arterial cast in the same organ. Microsphere deposition is used as an estimate of local perfusion. A 3D cylindrical pipe model of the arterial tree is generated based on an image of the arterial cast. Results of a flow model are compared with local microsphere deposition. High correlation (r(2) > 0.94) was observed between measured and modeled flows through the vascular tree segments. However, the relative dispersion of the microsphere perfusion measurement was two- to threefold higher than perfusion heterogeneity calculated in the flow model. Also, there was no correlation in the residual deviations between the methods. This study illustrates the importance of comparing models of local perfusion with in vivo measurements of perfusion in the same biologically realistic vascular tree.
Collapse
Affiliation(s)
- M Marxen
- Hospital for Sick Children Mouse Imaging Centre, 555 Univ. Ave, Toronto, Ontario, Canada
| | | | | | | | | |
Collapse
|
24
|
Aletras AH, Tilak GS, Natanzon A, Hsu LY, Gonzalez FM, Hoyt RF, Arai AE. Retrospective determination of the area at risk for reperfused acute myocardial infarction with T2-weighted cardiac magnetic resonance imaging: histopathological and displacement encoding with stimulated echoes (DENSE) functional validations. Circulation 2006; 113:1865-70. [PMID: 16606793 DOI: 10.1161/circulationaha.105.576025] [Citation(s) in RCA: 451] [Impact Index Per Article: 25.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND The aim of this study was to determine whether edema imaging by T2-weighted cardiac magnetic resonance (CMR) imaging could retrospectively delineate the area at risk in reperfused myocardial infarction. We hypothesized that the size of the area at risk during a transient occlusion would be similar to the T2-weighted hyperintense region observed 2 days later, that the T2-weighted hyperintense myocardium would show partial functional recovery after 2 months, and that the T2 abnormality would resolve over 2 months. METHODS AND RESULTS Seventeen dogs underwent a 90-minute coronary artery occlusion, followed by reperfusion. The area at risk, as measured with microspheres (9 animals), was comparable to the size of the hyperintense zone on T2-weighted images 2 days later (43.4+/-3.3% versus 43.0+/-3.4% of the left ventricle; P=NS), and the 2 measures correlated (R=0.84). The infarcted zone was significantly smaller (23.1+/-3.7; both P<0.001). To test whether the hyperintense myocardium would exhibit partial functional recovery over time, 8 animals were imaged on day 2 and 2 months later. Systolic strain was mapped with displacement encoding with stimulated echoes. Edema, as detected by a hyperintense zone on T2-weighted images, resolved, and regional radial systolic strain partially improved from 4.9+/-0.7 to 13.1+/-1.5 (P=0.001) over 2 months. CONCLUSIONS These findings are consistent with the premise that the T2 abnormality depicts the area at risk, a zone of reversibly and irreversibly injured myocardium associated with reperfused subendocardial infarctions. The persistence of postischemic edema allows T2-weighted CMR to delineate the area at risk 2 days after reperfused myocardial infarction.
Collapse
Affiliation(s)
- Anthony H Aletras
- National Heart, Lung and Blood Institute, National Institutes of Health, US Department of Health and Human Services, Bethesda, MD 20892-1061, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Hewett KW, Norman LW, Sedmera D, Barker RJ, Justus C, Zhang J, Kubalak SW, Gourdie RG. Knockout of the neural and heart expressed gene HF-1b results in apical deficits of ventricular structure and activation. Cardiovasc Res 2006; 67:548-60. [PMID: 15907824 PMCID: PMC3096008 DOI: 10.1016/j.cardiores.2005.04.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2004] [Revised: 03/31/2005] [Accepted: 04/04/2005] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE Knockout of the neural and cardiac expressed transcription factor HF-1b causes electrophysiological abnormalities including fatal ventricular arrhythmias that occur with increasing frequency around the 4th week of postnatal life. This study addresses factors that may contribute to conduction disturbance in the ventricle of the HF-1b knockout mouse. Disruptions to gap junctional connexin40 (Cx40) have been reported in distal (i.e., apically located), but not proximal His-Purkinje conduction tissues of the HF-1b knockout mouse. This abnormality in myocardial Cx40 led us to address whether 4-week-old HF-1b knockout postnates display other disruptions to ventricular structure and function. METHODS Western blotting and immunoconfocal quantification of Cx43 and coronary arteriole density and function were undertaken in the ventricle. Electrical activation was described by optical mapping. RESULTS Western blotting and immunoconfocal microscopy indicated that overall levels of Cx43 (p<0.001) and percent of Cx43 localized in intercalated disks (p<0.001) were significantly decreased in the ventricular myocardium of knockouts relative to wildtype littermate controls. Analysis of the reduction in Cx43 level by basal and apical territories revealed that the decrease was most pronounced in the lower, apical half of the ventricle of knockouts relative to controls (p<0.001). Myocyte size also showed a significant decrease in the knockout, that was more marked within the apical half of the ventricle (p<0.05). Optical recordings of ventricular activation indicated apically localized sectors of slowed conduction in knockout ventricles not occurring in controls that could be correlated directly to tissues showing reduced Cx43. These discrete sectors of abnormal conduction in the knockout heart were resolved following point stimulation of the ventricular epicardium and thus were not explained by dysfunction of the His-Purkinje system. To further probe base-to-apex abnormalities in the HF-1b knockout ventricle, we analyzed coronary arterial structure and function. These analyses indicated that relative to controls, the apical ventricular territory of the HF-1b knockout had reductions in the density of small resistance vessels (p<0.01) and deficits in arterial function as assayed by bead perfusion (p<0.01). CONCLUSION The HF-1b knockout ventricle displays abnormalities in Cx43 level, myocyte size, activation spread and coronary arterial structure and function. These abnormalities tend to be more pronounced in the apical territory of the ventricle and seem likely to be factors contributing to the pathological disturbance of cardiac conduction that characterizes the heart of the HF-1b knockout mouse.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Robert G. Gourdie
- Corresponding author. Tel.: +1 843 792 8181; fax: +1 843 792 0664. (R.G. Gourdie)
| |
Collapse
|
26
|
|
27
|
Matsumoto T, Asano T, Mano K, Tachibana H, Todoh M, Tanaka M, Kajiya F. Regional myocardial perfusion under exchange transfusion with liposomal hemoglobin: in vivo and in vitro studies using rat hearts. Am J Physiol Heart Circ Physiol 2005; 288:H1909-14. [PMID: 15576434 DOI: 10.1152/ajpheart.00976.2004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this study was to test the hypothesis that exchange transfusion with liposomal hemoglobin (LH) reduces the microheterogeneity of regional myocardial flows while sustaining cardiac function. Neo Red Cell mixed with albumin was used as the LH solution, in which the LH volume fraction was 17∼18% and hemoglobin density was nearly two-thirds smaller than in rat blood. Regional myocardial flows in left ventricular free walls were measured by tracer digitalradiography (100-μm resolution) in anesthetized rats with or without 50% blood-LH exchange transfusion. Within-layer flow distributions showed lower heterogeneity with ( n = 8) than without ( n = 8) LH transfusion. No extravasation of hemoglobin was confirmed by 3,3-diaminobenzidin staining ( n = 2). Carotid flow increased by 68% due to LH transfusion, whereas arterial pressure and heart rate remained unchanged. On the other hand, cross-circulated rat hearts ( n = 7) were used to evaluate the effects of 50% blood-LH exchange on coronary flow and tone preservation under 300-beats/min pacing and 100-mmHg perfusion pressure. Blood-LH exchange caused a 71% increase of coronary flow and 10% decrease of percent flow increase during hyperemia after 30-s flow interruption. Myocardial O2 supply and consumption increased by 9% and 10%, respectively, whereas myocardial O2 extraction remained unchanged. The large increases of in vivo carotid flow and coronary flow in cross-circulated hearts due to LH coperfusion could be explained by the reduction of apparent flow viscosity. These results suggest that under LH coperfusion, the microheterogeneity of myocardial flows decreases with increased coronary flow while fairly preserving coronary tone and cardiac function.
Collapse
Affiliation(s)
- T Matsumoto
- Division of Bioengineering, Osaka University Graduate School of Engineering Science, Machikaneyama-machi 1-3, Toyonaka 560-8531, Japan.
| | | | | | | | | | | | | |
Collapse
|