1
|
Suderman RP, Hurtig MB, Grynpas MD, Kuzyk PRT, Changoor A. Effect of Press-Fit Size on Insertion Mechanics and Cartilage Viability in Human and Ovine Osteochondral Grafts. Cartilage 2024:19476035241247297. [PMID: 38651510 DOI: 10.1177/19476035241247297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/25/2024] Open
Abstract
OBJECTIVE The osteochondral allograft procedure uses grafts constructed larger than the recipient site to stabilize the graft, in what is known as the press-fit technique. This research aims to characterize the relationships between press-fit size, insertion forces, and cell viability in ovine and human osteochondral tissue. DESIGN Human (4 donors) and ovine (5 animals) articular joints were used to harvest osteochondral grafts (4.55 mm diameter, N = 33 Human, N = 35 Ovine) and create recipient sites with grafts constructed to achieve varying degrees of press fit (0.025-0.240 mm). Donor grafts were inserted into recipient sites while insertion forces were measured followed by quantification of chondrocyte viability and histological staining to evaluate the extracellular matrix. RESULTS Both human and ovine tissues exhibited similar mechanical and cellular responses to changes in press-fit. Insertion forces (Human: 3-169 MPa, Ovine: 36-314 MPa) and cell viability (Human: 16%-89% live, Ovine: 2%-76% live) were correlated to press-fit size for both human (force: r = 0.539, viability: r = -0.729) and ovine (force: r = 0.655, viability: r = -0.714) tissues. In both species, a press-fit above 0.14 mm resulted in reduced cell viability below a level acceptable for transplantation, increased insertion forces, and reduced linear correlation to press-fit size compared to samples with a press-fit below 0.14 mm. CONCLUSIONS Increasing press-fit size required increased insertion forces and resulted in reduced cell viability. Ovine and human osteochondral tissues responded similarly to impact insertion and varying press-fit size, providing evidence for the use of the ovine model in allograft-related research.
Collapse
Affiliation(s)
- R P Suderman
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
- Kierans Janigan Biomechanics Research Program, Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, ON, Canada
| | - M B Hurtig
- Comparative Orthopaedic Research Laboratory, Department of Clinical Studies, University of Guelph, Guelph, ON, Canada
| | - M D Grynpas
- Kierans Janigan Biomechanics Research Program, Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, ON, Canada
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Department of Material Science & Engineering, University of Toronto, Toronto, ON, Canada
| | - P R T Kuzyk
- Kierans Janigan Biomechanics Research Program, Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, ON, Canada
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - A Changoor
- Kierans Janigan Biomechanics Research Program, Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, ON, Canada
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Department of Material Science & Engineering, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
2
|
Erbulut DU, Sadeqi S, Summers R, Goel VK. Tibiofemoral Cartilage Contact Pressures in Athletes During Landing: A Dynamic Finite Element Study. J Biomech Eng 2021; 143:101006. [PMID: 34008847 PMCID: PMC8299805 DOI: 10.1115/1.4051231] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 05/06/2021] [Indexed: 12/21/2022]
Abstract
Cartilage defects are common in the knee joint of active athletes and remain a problem as a strong risk factor for osteoarthritis. We hypothesized that landing during sport activities, implication for subfailure ACL loading, would generate greater contact pressures (CP) at the lateral knee compartment. The purpose of this study is to investigate tibiofemoral cartilage CP of athletes during landing. Tibiofemoral cartilage contact pressures (TCCP) under clinically relevant anterior cruciate ligament subfailure external loadings were predicted using four dynamic explicit finite element (FE) models (2 males and 2 females) of the knee. Bipedal landing from a jump for five cases of varying magnitudes of external loadings (knee abduction moment, internal tibial torque, and anterior tibial shear) followed by an impact load were simulated. Lateral TCCP from meniscus (area under meniscus) and from femur (area under femur) increased by up to 94% and %30 respectively when external loads were incorporated with impact load in all the models compared to impact-only case. In addition, FE model predicted higher CP in lateral compartment by up to 37% (11.87 MPa versus 8.67 MPa) and 52% (20.19 MPa versus 13.29 MPa) for 90% and 50% percentile models, respectively. For the same percentile populations, CPs were higher by up to 25% and 82% in smaller size models than larger size models. We showed that subfailure ACL loadings obtained from previously conducted in vivo study led to high pressures on the tibiofemoral cartilage. This knowledge is helpful in enhancing neuromuscular training for athletes to prevent cartilage damage.
Collapse
Affiliation(s)
- Deniz U. Erbulut
- Engineering Center for Orthopaedics Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedics, The University of Toledo, Toledo, OH 43606; Herston Biofabrication Institute, Metro North Hospital and Health Service, Brisbane, QLD 4029, Australia
| | - Sara Sadeqi
- Engineering Center for Orthopaedics Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedics, The University of Toledo, Toledo, OH 43606
| | - Rodney Summers
- Engineering Center for Orthopaedics Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedics, The University of Toledo, Toledo, OH 43606
| | - Vijay K. Goel
- Engineering Center for Orthopaedics Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedics, The University of Toledo, Toledo, OH 43606
| |
Collapse
|
3
|
Zainal Abidin NA, Abdul Wahab AH, Abdul Rahim RA, Abdul Kadir MR, Ramlee MH. Biomechanical analysis of three different types of fixators for anterior cruciate ligament reconstruction via finite element method: a patient-specific study. Med Biol Eng Comput 2021; 59:1945-1960. [PMID: 34392448 DOI: 10.1007/s11517-021-02419-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/26/2021] [Indexed: 01/11/2023]
Abstract
Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.
Collapse
Affiliation(s)
- Nur Afikah Zainal Abidin
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.,Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia
| | - Abdul Hadi Abdul Wahab
- Centre for Multimodal Signal Processing, Faculty of Engineering and Technology, Tunku Abdul Rahman Universiti College, Jalan Genting Kelang, 53300, Setapak, Kuala Lumpur, Malaysia.,Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Tunku Abdul Rahman Universiti College, Jalan Genting Kelang, 53300, Setapak, Kuala Lumpur, Malaysia
| | - Rabiatul Adibah Abdul Rahim
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia
| | - Mohammed Rafiq Abdul Kadir
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.,Sports Innovation and Technology Centre (SITC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, UTM, 81310, Johor Bahru, Johor, Malaysia
| | - Muhammad Hanif Ramlee
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia. .,Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
| |
Collapse
|
4
|
Bahraminasab M. Challenges on optimization of 3D-printed bone scaffolds. Biomed Eng Online 2020; 19:69. [PMID: 32883300 PMCID: PMC7469110 DOI: 10.1186/s12938-020-00810-2] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/22/2020] [Indexed: 12/15/2022] Open
Abstract
Advances in biomaterials and the need for patient-specific bone scaffolds require modern manufacturing approaches in addition to a design strategy. Hybrid materials such as those with functionally graded properties are highly needed in tissue replacement and repair. However, their constituents, proportions, sizes, configurations and their connection to each other are a challenge to manufacturing. On the other hand, various bone defect sizes and sites require a cost-effective readily adaptive manufacturing technique to provide components (scaffolds) matching with the anatomical shape of the bone defect. Additive manufacturing or three-dimensional (3D) printing is capable of fabricating functional physical components with or without porosity by depositing the materials layer-by-layer using 3D computer models. Therefore, it facilitates the production of advanced bone scaffolds with the feasibility of making changes to the model. This review paper first discusses the development of a computer-aided-design (CAD) approach for the manufacture of bone scaffolds, from the anatomical data acquisition to the final model. It also provides information on the optimization of scaffold's internal architecture, advanced materials, and process parameters to achieve the best biomimetic performance. Furthermore, the review paper describes the advantages and limitations of 3D printing technologies applied to the production of bone tissue scaffolds.
Collapse
Affiliation(s)
- Marjan Bahraminasab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran.
- Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.
| |
Collapse
|
5
|
Design of a novel procedure for the optimization of the mechanical performances of 3D printed scaffolds for bone tissue engineering combining CAD, Taguchi method and FEA. Med Eng Phys 2019; 69:92-99. [PMID: 31101484 DOI: 10.1016/j.medengphy.2019.04.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 03/11/2019] [Accepted: 04/28/2019] [Indexed: 12/22/2022]
Abstract
In order to increase manufacturing and experimental efficiency, a certain degree of control over design performances before realization phase is recommended. In this context, this paper presents an integrated procedure to design 3D scaffolds for bone tissue engineering. The procedure required a combination of Computer Aided Design (CAD), Finite Element Analysis (FEA), and Design methodologies Of Experiments (DOE), firstly to understand the influence of the design parameters, and then to control them. Based on inputs from the literature and limitations imposed by the chosen manufacturing process (Precision Extrusion Deposition), 36 scaffold architectures have been drawn. The porosity of each scaffold has been calculated with CAD. Thereafter, a generic scaffold material was considered and its variable parameters were combined with the geometrical ones according to the Taguchi method, i.e. a DOE method. The compressive response of those principal combinations was simulated by FEA, and the influence of each design parameter on the scaffold compressive behaviour was clarified. Finally, a regression model was obtained correlating the scaffold's mechanical performances to its geometrical and material parameters. This model has been applied to a novel composite material made of polycaprolactone and innovative bioactive glass. By setting specific porosity (50%) and stiffness (0.05 GPa) suitable for trabecular bone substitutes, the model selected 4 of the 36 initial scaffold architectures. Only these 4 more promising geometries will be realized and physically tested for advanced indications on compressive strength and biocompatibility.
Collapse
|
6
|
Jalal N, Zidi M. Influence of experimental conditions on visco-hyperelastic properties of skeletal muscle tissue using a Box-Behnken design. J Biomech 2019; 85:204-209. [PMID: 30732908 DOI: 10.1016/j.jbiomech.2019.01.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2018] [Revised: 01/01/2019] [Accepted: 01/08/2019] [Indexed: 10/27/2022]
Abstract
The Mechanical characterization of skeletal muscles is strongly dependent on numerous experimental design factors. Nevertheless, significant knowledge gaps remain on the characterization of muscle mechanics and a large number of experiments should be implemented to test the influence of a large number of factors. In this study, we propose a design of experiment method (DOE) to study the parameter sensitivity while minimizing the number of tests. A Box-Behnken design was then implemented to study the influence of strain rate, preconditioning and preloading conditions on visco-hyperelastic mechanical parameters of two rat forearm muscles. The results show that the strain rate affects the visco-hyperelastic parameters for both muscles. These results are consistent with previous work demonstrating that stiffness and viscoelastic contributions increase with strain rate. Thus, DOE has been shown to be a valid method to determine the effect of the experimental conditions on the mechanical behaviour of biological tissues such as skeletal muscle. This method considerably reduces the number of experiments. Indeed, the presented study using 3 parameters at 3 levels would have required at least 54 tests per muscle against 14 for the proposed DOE method.
Collapse
Affiliation(s)
- Naïm Jalal
- Bioengineering, Tissues and Neuroplasticity, EA 7377, Université Paris-Est Créteil, Faculté de Médecine, 8 rue du Général Sarrail, 94010 Créteil, France
| | - Mustapha Zidi
- Bioengineering, Tissues and Neuroplasticity, EA 7377, Université Paris-Est Créteil, Faculté de Médecine, 8 rue du Général Sarrail, 94010 Créteil, France.
| |
Collapse
|
7
|
Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? J Biomech 2014; 48:767-78. [PMID: 25560273 DOI: 10.1016/j.jbiomech.2014.12.019] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/26/2014] [Indexed: 11/23/2022]
Abstract
Finite element has been used for more than four decades to study and evaluate the mechanical behaviour total joint replacements. In Huiskes seminal paper "Failed innovation in total hip replacement: diagnosis and proposals for a cure", finite element modelling was one of the potential cures to avoid poorly performing designs reaching the market place. The size and sophistication of models has increased significantly since that paper and a range of techniques are available from predicting the initial mechanical environment through to advanced adaptive simulations including bone adaptation, tissue differentiation, damage accumulation and wear. However, are we any closer to FE becoming an effective screening tool for new devices? This review contains a critical analysis of currently available finite element modelling techniques including (i) development of the basic model, the application of appropriate material properties, loading and boundary conditions, (ii) describing the initial mechanical environment of the bone-implant system, (iii) capturing the time dependent behaviour in adaptive simulations, (iv) the design and implementation of computer based experiments and (v) determining suitable performance metrics. The development of the underlying tools and techniques appears to have plateaued and further advances appear to be limited either by a lack of data to populate the models or the need to better understand the fundamentals of the mechanical and biological processes. There has been progress in the design of computer based experiments. Historically, FE has been used in a similar way to in vitro tests, by running only a limited set of analyses, typically of a single bone segment or joint under idealised conditions. The power of finite element is the ability to run multiple simulations and explore the performance of a device under a variety of conditions. There has been increasing usage of design of experiments, probabilistic techniques and more recently population based modelling to account for patient and surgical variability. In order to have effective screening methods, we need to continue to develop these approaches to examine the behaviour and performance of total joint replacements and benchmark them for devices with known clinical performance. Finite element will increasingly be used in the design, development and pre-clinical testing of total joint replacements. However, simulations must include holistic, closely corroborated, multi-domain analyses which account for real world variability.
Collapse
|