1
|
She X, Nix KC, Cline CC, Qi W, Tugin S, He Z, Baumer FM. Stability of transcranial magnetic stimulation electroencephalogram evoked potentials in pediatric epilepsy. Sci Rep 2024; 14:9045. [PMID: 38641629 PMCID: PMC11031596 DOI: 10.1038/s41598-024-59468-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 04/11/2024] [Indexed: 04/21/2024] Open
Abstract
Transcranial magnetic stimulation paired with electroencephalography (TMS-EEG) can measure local excitability and functional connectivity. To address trial-to-trial variability, responses to multiple TMS pulses are recorded to obtain an average TMS evoked potential (TEP). Balancing adequate data acquisition to establish stable TEPs with feasible experimental duration is critical when applying TMS-EEG to clinical populations. Here we aim to investigate the minimum number of pulses (MNP) required to achieve stable TEPs in children with epilepsy. Eighteen children with Self-Limited Epilepsy with Centrotemporal Spikes, a common epilepsy arising from the motor cortices, underwent multiple 100-pulse blocks of TMS to both motor cortices over two days. TMS was applied at 120% of resting motor threshold (rMT) up to a maximum of 100% maximum stimulator output. The average of all 100 pulses was used as a "gold-standard" TEP to which we compared "candidate" TEPs obtained by averaging subsets of pulses. We defined TEP stability as the MNP needed to achieve a concordance correlation coefficient of 80% between the candidate and "gold-standard" TEP. We additionally assessed whether experimental or clinical factors affected TEP stability. Results show that stable TEPs can be derived from fewer than 100 pulses, a number typically used for designing TMS-EEG experiments. The early segment (15-80 ms) of the TEP was less stable than the later segment (80-350 ms). Global mean field amplitude derived from all channels was less stable than local TEP derived from channels overlying the stimulated site. TEP stability did not differ depending on stimulated hemisphere, block order, or antiseizure medication use, but was greater in older children. Stimulation administered with an intensity above the rMT yielded more stable local TEPs. Studies of TMS-EEG in pediatrics have been limited by the complexity of experimental set-up and time course. This study serves as a critical starting point, demonstrating the feasibility of designing efficient TMS-EEG studies that use a relatively small number of pulses to study pediatric epilepsy and potentially other pediatric groups.
Collapse
Affiliation(s)
- Xiwei She
- Department of Neurology, Stanford University, Stanford, CA, USA
| | - Kerry C Nix
- Department of Neurology, Stanford University, Stanford, CA, USA
| | - Christopher C Cline
- Department of Psychiatry and Behavioral Sciences, Stanford University, Stanford, CA, USA
| | - Wendy Qi
- Department of Neurology, Stanford University, Stanford, CA, USA
| | - Sergei Tugin
- Department of Neurology, Stanford University, Stanford, CA, USA
- Department of Psychiatry and Behavioral Sciences, Stanford University, Stanford, CA, USA
| | - Zihuai He
- Department of Neurology, Stanford University, Stanford, CA, USA
| | - Fiona M Baumer
- Department of Neurology, Stanford University, Stanford, CA, USA.
| |
Collapse
|
2
|
Hohenester M, Langguth B, Wetter TC, Geisler P, Schecklmann M, Reissmann A. Single sessions of transcranial direct current stimulation and transcranial random noise stimulation exert no effect on sleepiness in patients with narcolepsy and idiopathic hypersomnia. Front Psychiatry 2023; 14:1288976. [PMID: 38146280 PMCID: PMC10749348 DOI: 10.3389/fpsyt.2023.1288976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 11/28/2023] [Indexed: 12/27/2023] Open
Abstract
Background Hypersomnia poses major challenges to treatment providers given the limitations of available treatment options. In this context, the application of non-invasive brain stimulation techniques such as transcranial electrical stimulation (tES) may open up new avenues to effective treatment. Preliminary evidence suggests both acute and longer-lasting positive effects of transcranial direct current stimulation (tDCS) on vigilance and sleepiness in hypersomniac patients. Based on these findings, the present study sought to investigate short-term effects of single sessions of tDCS and transcranial random noise stimulation (tRNS) on sleepiness in persons suffering from hypersomnia. Methods A sample of 29 patients suffering from narcolepsy or idiopathic hypersomnia (IH) was recruited from the Regensburg Sleep Disorder Center and underwent single sessions of tES (anodal tDCS, tRNS, sham) over the left and right dorsolateral prefrontal cortex on three consecutive days in a double-blind, sham-controlled, pseudorandomized crossover trial. The primary study endpoint was the mean reaction time measured by the Psychomotor Vigilance Task (PVT) before and directly after the daily tES sessions. Secondary endpoints were additional PVT outcome metrics as well as subjective outcome parameters (e.g., Karolinska Sleepiness Scale; KSS). Results There were no significant treatment effects neither on objective (i.e., PVT) nor on subjective indicators of sleepiness. Conclusion We could not demonstrate any clinically relevant effects of single sessions of tDCS or tRNS on objective or subjective measures of sleepiness in patients with hypersomnia. However, we cannot exclude that repeated sessions of tES may affect vigilance or sleepiness in hypersomniac patients.
Collapse
Affiliation(s)
- Michaela Hohenester
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
- Department of Hematology and Oncology, Krankenhaus der Barmherzigen Brüder Regensburg, Regensburg, Germany
| | - Berthold Langguth
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | | | - Peter Geisler
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Martin Schecklmann
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Andreas Reissmann
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| |
Collapse
|
3
|
Visalli A, Begliomini C, Mioni G. The effect of emotion intensity on time perception: a study with transcranial random noise stimulation. Exp Brain Res 2023:10.1007/s00221-023-06668-9. [PMID: 37477666 PMCID: PMC10386931 DOI: 10.1007/s00221-023-06668-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Accepted: 07/10/2023] [Indexed: 07/22/2023]
Abstract
Emotional facial expressions provide cues for social interactions and emotional events can distort our sense of time. The present study investigates the effect of facial emotional stimuli of anger and sadness on time perception. Moreover, to investigate the causal role of the orbitofrontal cortex (OFC) in emotional recognition, we employed transcranial random noise stimulation (tRNS) over OFC and tested the effect on participants' emotional recognition as well as on time processing. Participants performed a timing task in which they were asked to categorize as "short" or "long" temporal intervals marked by images of people expressing anger, sad or neutral emotional facial expressions. In addition, they were asked to judge if the image presented was of a person expressing anger or sadness. The visual stimuli were facial emotional stimuli indicating anger or sadness with different degrees of intensity at high (80%), medium (60%) and low (40%) intensity, along with neutral emotional face stimuli. In the emotional recognition task, results showed that participants were faster and more accurate when emotional intensity was higher. Moreover, tRNS over OFC interfered with emotion recognition, which is in line with its proposed role in emotion recognition. In the timing task, participants overestimated the duration of angry facial expressions, although neither emotional intensity not OFC stimulation significantly modulated this effect. Conversely, as the emotional intensity increased, participants exhibited a greater tendency to overestimate the duration of sad faces in the sham condition. However, this tendency disappeared with tRNS. Taken together, our results are partially consistent with previous findings showing an overestimation effect of emotionally arousing stimuli, revealing the involvement of OFC in emotional distortions of time, which needs further investigation.
Collapse
Affiliation(s)
| | - Chiara Begliomini
- Department of General Psychology, University of Padova, 35131, Padua, Italy
- Padova Neuroscience Center, Padua, Italy
| | - Giovanna Mioni
- Department of General Psychology, University of Padova, 35131, Padua, Italy.
| |
Collapse
|
4
|
Qi F, Nitsche MA, Ren X, Wang D, Wang L. Top-down and bottom-up stimulation techniques combined with action observation treatment in stroke rehabilitation: a perspective. Front Neurol 2023; 14:1156987. [PMID: 37497013 PMCID: PMC10367110 DOI: 10.3389/fneur.2023.1156987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 06/26/2023] [Indexed: 07/28/2023] Open
Abstract
Stroke is a central nervous system disease that causes structural lesions and functional impairments of the brain, resulting in varying types, and degrees of dysfunction. The bimodal balance-recovery model (interhemispheric competition model and vicariation model) has been proposed as the mechanism of functional recovery after a stroke. We analyzed how combinations of motor observation treatment approaches, transcranial electrical (TES) or magnetic (TMS) stimulation and peripheral electrical (PES) or magnetic (PMS) stimulation techniques can be taken as accessorial physical therapy methods on symptom reduction of stroke patients. We suggest that top-down and bottom-up stimulation techniques combined with action observation treatment synergistically might develop into valuable physical therapy strategies in neurorehabilitation after stroke. We explored how TES or TMS intervention over the contralesional hemisphere or the lesioned hemisphere combined with PES or PMS of the paretic limbs during motor observation followed by action execution have super-additive effects to potentiate the effect of conventional treatment in stroke patients. The proposed paradigm could be an innovative and adjunctive approach to potentiate the effect of conventional rehabilitation treatment, especially for those patients with severe motor deficits.
Collapse
Affiliation(s)
- Fengxue Qi
- Sports, Exercise and Brain Sciences Laboratory, Beijing Sport University, Beijing, China
| | - Michael A. Nitsche
- Department of Psychology and Neurosciences, Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany
| | - Xiping Ren
- College of Physical Education and Health Sciences, Zhejiang Normal University, Jinhua, China
| | - Duanwei Wang
- Shandong Mental Health Center, Shandong University, Jinan, Shandong, China
| | - Lijuan Wang
- Key Laboratory of Exercise and Physical Fitness, Ministry of Education, Beijing Sport University, Beijing, China
- School of Sports Medicine and Rehabilitation, Beijing Sport University, Beijing, China
| |
Collapse
|
5
|
Brancucci A, Rivolta D, Nitsche MA, Manippa V. The effects of transcranial random noise stimulation on motor function: A comprehensive review of the literature. Physiol Behav 2023; 261:114073. [PMID: 36608913 DOI: 10.1016/j.physbeh.2023.114073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/23/2022] [Accepted: 01/01/2023] [Indexed: 01/05/2023]
Abstract
The present review considers all papers published on the topic up to the end of the year 2022. Transcranial random noise stimulation (tRNS) is a non-invasive neuromodulation technique introduced about 15 years ago whose use is becoming increasingly widespread in neuroscience. It consists of the application over the scalp of a weak, white noise-like current, through electrodes having a surface of several square centimetres, for a duration ranging from seconds to minutes. Despite its relatively low spatial and temporal resolution, tRNS has well defined effects on central motor excitability, which critically depend on stimulation parameters. These effects seem to be chiefly based on an effect on neuronal membrane sodium channels and can last much longer than the stimulation itself. While the effects at the cellular level in the motor cortex are becoming progressively clear, much more studies are needed to understand the effects of tRNS on motor behaviour and performance, where initial research results are nevertheless promising, in both basic and applied research.
Collapse
Affiliation(s)
- Alfredo Brancucci
- Dipartimento di Scienze Motorie, Umane e della Salute, Università di Roma "Foro Italico", Italy.
| | - Davide Rivolta
- Dipartimento di Scienze della Formazione, Psicologia, Comunicazione, Università degli studi di Bari "Aldo Moro", Italy
| | - Michael A Nitsche
- Department of Psychology and Neurosciences, Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany; Bielefeld University, University Hospital OWL, Protestant Hospital of Bethel Foundation, University Clinic of Psychiatry and Psychotherapy and University Clinic of Child and Adolescent Psychiatry and Psychotherapy, Germany
| | - Valerio Manippa
- Dipartimento di Scienze della Formazione, Psicologia, Comunicazione, Università degli studi di Bari "Aldo Moro", Italy; Department of Psychology and Neurosciences, Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany
| |
Collapse
|
6
|
Transcranial high-frequency random noise stimulation does not modulate Nogo N2 and Go/Nogo reaction times in somatosensory and auditory modalities. Sci Rep 2023; 13:3014. [PMID: 36810889 PMCID: PMC9944265 DOI: 10.1038/s41598-023-30261-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 02/20/2023] [Indexed: 02/24/2023] Open
Abstract
Transcranial random noise stimulation (tRNS) of the primary sensory or motor cortex can improve sensorimotor functions by enhancing circuit excitability and processing fidelity. However, tRNS is reported to have little effect on higher brain functions, such as response inhibition when applied to associated supramodal regions. These discrepancies suggest differential effects of tRNS on the excitability of the primary and supramodal cortex, although this has not been directly demonstrated. This study examined the effects of tRNS on supramodal brain regions on somatosensory and auditory Go/Nogo task performance, a measure of inhibitory executive function, while simultaneously recording event-related potentials (ERPs). Sixteen participants received sham or tRNS stimulation of the dorsolateral prefrontal cortex in a single-blind crossover design study. Neither sham nor tRNS altered somatosensory and auditory Nogo N2 amplitudes, Go/Nogo reaction times, or commission error rates. The results suggest that current tRNS protocols are less effective at modulating neural activity in higher-order cortical regions than in the primary sensory and motor cortex. Further studies are required to identify tRNS protocols that effectively modulate the supramodal cortex for cognitive enhancement.
Collapse
|
7
|
Mondino M, Janin D, Galvao F, Brunelin J. High-Frequency Transcranial Random Noise Stimulation for Auditory Hallucinations of Schizophrenia: A Case Series. Biomedicines 2022; 10:2698. [PMID: 36359217 PMCID: PMC9687535 DOI: 10.3390/biomedicines10112698] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/26/2022] [Accepted: 10/18/2022] [Indexed: 09/19/2023] Open
Abstract
Transcranial electrical stimulation has been proposed as a noninvasive therapeutic approach for reducing treatment-resistant symptoms of schizophrenia-in particular, auditory hallucinations. However, the high variability observed in the clinical response leaves much room to optimize the stimulation parameters and strengthen its benefits. We proposed to investigate the effects of high-frequency transcranial random noise stimulation (hf-tRNS), which is supposed to induce larger effects than conventional direct current stimulation. Here, we present an initial case series of ten patients with schizophrenia who underwent 10 sessions of 20 min hf-tRNS (2 mA, 100-500 Hz, 1 mA offset), with the anode placed over the left dorsolateral prefrontal cortex and the cathode over the left temporoparietal junction. Patients showed a significant reduction in auditory hallucinations after the hf-tRNS sessions (-36.1 +/- 21.8%, p = 0.0059). In this preliminary, open-label study conducted in ten patients with treatment-resistant symptoms of schizophrenia, frontotemporal hf-tRNS was shown to induce a substantial improvement in auditory hallucinations. Additional sham-controlled studies are needed to further evaluate hf-tRNS as a treatment for schizophrenia.
Collapse
Affiliation(s)
- Marine Mondino
- Pôle Est, Centre Hospitalier Le Vinatier, F-69500 Bron, France
- PSYR2 Team, Lyon Neuroscience Research Center, INSERM U1028, CNRS UMR5292, F-69000 Lyon, France
- University Lyon 1, F-69100 Villeurbanne, France
| | - Delphine Janin
- Pôle Est, Centre Hospitalier Le Vinatier, F-69500 Bron, France
- PSYR2 Team, Lyon Neuroscience Research Center, INSERM U1028, CNRS UMR5292, F-69000 Lyon, France
- University Lyon 1, F-69100 Villeurbanne, France
| | - Filipe Galvao
- Pôle Est, Centre Hospitalier Le Vinatier, F-69500 Bron, France
| | - Jérôme Brunelin
- Pôle Est, Centre Hospitalier Le Vinatier, F-69500 Bron, France
- PSYR2 Team, Lyon Neuroscience Research Center, INSERM U1028, CNRS UMR5292, F-69000 Lyon, France
- University Lyon 1, F-69100 Villeurbanne, France
| |
Collapse
|
8
|
Boosting psychological change: Combining non-invasive brain stimulation with psychotherapy. Neurosci Biobehav Rev 2022; 142:104867. [PMID: 36122739 DOI: 10.1016/j.neubiorev.2022.104867] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 09/01/2022] [Accepted: 09/07/2022] [Indexed: 11/21/2022]
Abstract
Mental health disorders and substance use disorders are a leading cause of morbidity and mortality worldwide, and one of the most important challenges for public health systems. While evidence-based psychotherapy is generally pursued to address mental health challenges, psychological change is often hampered by non-adherence to treatments, relapses, and practical barriers (e.g., time, cost). In recent decades, Non-invasive brain stimulation (NIBS) techniques have emerged as promising tools to directly target dysfunctional neural circuitry and promote long-lasting plastic changes. While the therapeutic efficacy of NIBS protocols for mental illnesses has been established, neuromodulatory interventions might also be employed to support the processes activated by psychotherapy. Indeed, combining psychotherapy with NIBS might help tailor the treatment to the patient's unique characteristics and therapeutic goal, and would allow more direct control of the neuronal changes induced by therapy. Herein, we overview emerging evidence on the use of NIBS to enhance the psychotherapeutic effect, while highlighting the next steps in advancing clinical and research methods toward personalized intervention approaches.
Collapse
|
9
|
Vergallito A, Feroldi S, Pisoni A, Romero Lauro LJ. Inter-Individual Variability in tDCS Effects: A Narrative Review on the Contribution of Stable, Variable, and Contextual Factors. Brain Sci 2022; 12:522. [PMID: 35624908 PMCID: PMC9139102 DOI: 10.3390/brainsci12050522] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 04/08/2022] [Accepted: 04/14/2022] [Indexed: 01/27/2023] Open
Abstract
Due to its safety, portability, and cheapness, transcranial direct current stimulation (tDCS) use largely increased in research and clinical settings. Despite tDCS's wide application, previous works pointed out inconsistent and low replicable results, sometimes leading to extreme conclusions about tDCS's ineffectiveness in modulating behavioral performance across cognitive domains. Traditionally, this variability has been linked to significant differences in the stimulation protocols across studies, including stimulation parameters, target regions, and electrodes montage. Here, we reviewed and discussed evidence of heterogeneity emerging at the intra-study level, namely inter-individual differences that may influence the response to tDCS within each study. This source of variability has been largely neglected by literature, being results mainly analyzed at the group level. Previous research, however, highlighted that only a half-or less-of studies' participants could be classified as responders, being affected by tDCS in the expected direction. Stable and variable inter-individual differences, such as morphological and genetic features vs. hormonal/exogenous substance consumption, partially account for this heterogeneity. Moreover, variability comes from experiments' contextual elements, such as participants' engagement/baseline capacity and individual task difficulty. We concluded that increasing knowledge on inter-dividual differences rather than undermining tDCS effectiveness could enhance protocols' efficiency and reproducibility.
Collapse
Affiliation(s)
- Alessandra Vergallito
- Department of Psychology & NeuroMi, University of Milano Bicocca, 20126 Milano, Italy; (A.P.); (L.J.R.L.)
| | - Sarah Feroldi
- School of Medicine and Surgery, University of Milano-Bicocca, 20854 Monza, Italy;
| | - Alberto Pisoni
- Department of Psychology & NeuroMi, University of Milano Bicocca, 20126 Milano, Italy; (A.P.); (L.J.R.L.)
| | - Leonor J. Romero Lauro
- Department of Psychology & NeuroMi, University of Milano Bicocca, 20126 Milano, Italy; (A.P.); (L.J.R.L.)
| |
Collapse
|
10
|
Ni R, Yuan Y, Yang L, Meng Q, Zhu Y, Zhong Y, Cao Z, Zhang S, Yao W, Lv D, Chen X, Chen X, Bu J. Novel Non-invasive Transcranial Electrical Stimulation for Parkinson's Disease. Front Aging Neurosci 2022; 14:880897. [PMID: 35493922 PMCID: PMC9039727 DOI: 10.3389/fnagi.2022.880897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 03/15/2022] [Indexed: 11/25/2022] Open
Abstract
Conventional transcranial electrical stimulation (tES) is a non-invasive method to modulate brain activity and has been extensively used in the treatment of Parkinson's disease (PD). Despite promising prospects, the efficacy of conventional tES in PD treatment is highly variable across different studies. Therefore, many have tried to optimize tES for an improved therapeutic efficacy by developing novel tES intervention strategies. Until now, these novel clinical interventions have not been discussed or reviewed in the context of PD therapy. In this review, we focused on the efficacy of these novel strategies in PD mitigation, classified them into three categories based on their distinct technical approach to circumvent conventional tES problems. The first category has novel stimulation modes to target different modulating mechanisms, expanding the rang of stimulation choices hence enabling the ability to modulate complex brain circuit or functional networks. The second category applies tES as a supplementary intervention for PD hence amplifies neurological or behavioral improvements. Lastly, the closed loop tES stimulation can provide self-adaptive individualized stimulation, which enables a more specialized intervention. In summary, these novel tES have validated potential in both alleviating PD symptoms and improving understanding of the pathophysiological mechanisms of PD. However, to assure wide clinical used of tES therapy for PD patients, further large-scale trials are required.
Collapse
Affiliation(s)
- Rui Ni
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
- Department of Life Sciences, Imperial College London, London, United Kingdom
| | - Ye Yuan
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Li Yang
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Qiujian Meng
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Ying Zhu
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Yiya Zhong
- Department of Life Sciences, Imperial College London, London, United Kingdom
| | - Zhenqian Cao
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Shengzhao Zhang
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Wenjun Yao
- Department of Radiology, The Second Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Daping Lv
- Department of Neurology, The Fourth Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Xin Chen
- Department of Neurology, The Fourth Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Xianwen Chen
- Department of Neurology, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Junjie Bu
- Department of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, China
- Department of Neurosurgery, The Fourth Affiliated Hospital of Anhui Medical University, Hefei, China
| |
Collapse
|
11
|
Iddings JA, Zarkou A, Field-Fote EC. Noninvasive neuromodulation and rehabilitation to promote functional restoration in persons with spinal cord injury. Curr Opin Neurol 2021; 34:812-818. [PMID: 34766554 PMCID: PMC8597924 DOI: 10.1097/wco.0000000000000997] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE OF REVIEW This review will focus on the use of clinically accessible neuromodulatory approaches for functional restoration in persons with spinal cord injury (SCI). RECENT FINDINGS Functional restoration is a primary rehabilitation priority for individuals with SCI. High-tech neuromodulatory modalities have been used in laboratory settings to improve hand and walking function as well as to reduce spasticity and pain in persons with SCI. However, the cost, limited accessibility, and required expertise are prohibitive for clinical applicability of these high-tech modalities. Recent literature indicates that noninvasive and clinically accessible approaches targeting supraspinal, spinal, and peripheral neural structures can modulate neural excitability. Although a limited number of studies have examined the use of these approaches for functional restoration and amelioration of secondary complications in SCI, early evidence investigating their efficacy when combined with training is encouraging. SUMMARY Larger sample studies addressing both biomarker identification and dosing are crucial next steps in the field of neurorehabilitation research before novel noninvasive stimulation approaches can be incorporated into standard clinical practice.
Collapse
Affiliation(s)
- Jennifer A Iddings
- Spinal Cord Injury Research Laboratory, Crawford Research Institute, Shepherd Center
| | - Anastasia Zarkou
- Spinal Cord Injury Research Laboratory, Crawford Research Institute, Shepherd Center
| | - Edelle C Field-Fote
- Spinal Cord Injury Research Laboratory, Crawford Research Institute, Shepherd Center
- Division of Physical Therapy, School of Medicine, Emory University
- Program in Applied Physiology, School of Biological Sciences, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
12
|
Zhang M, Cheng I, Sasegbon A, Dou Z, Hamdy S. Exploring parameters of gamma transcranial alternating current stimulation (tACS) and full-spectrum transcranial random noise stimulation (tRNS) on human pharyngeal cortical excitability. Neurogastroenterol Motil 2021; 33:e14173. [PMID: 34081376 DOI: 10.1111/nmo.14173] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 04/25/2021] [Accepted: 04/28/2021] [Indexed: 02/08/2023]
Abstract
BACKGROUND Transcranial alternating current stimulation (tACS) and transcranial random noise stimulation (tRNS) have been shown to have physiological and functional effects on brain excitability and motor behavior. Yet, little is known about their effects in the swallowing system. AIM To examine the effects and optimal stimulation parameters of tACS and tRNS for modulating excitability of human pharyngeal motor cortex. METHODS 10 Hz (alpha), 20 Hz (beta), 70 Hz (gamma) tACS, 0.1-640 Hz (full-spectrum) tRNS, and sham were applied over pharyngeal motor cortices at 1.5 mA current intensity for 10 min in 15 healthy participants. Pharyngeal motor-evoked and thenar motor-evoked potentials (PMEPs and TMEPs) were assessed before and up to 2 h after stimulation with single-pulse transcranial magnetic stimulation. Averaged MEP amplitude and latency changes were analyzed using repeated measures ANOVA (rmANOVA). KEY RESULTS Two-way rmANOVA across all active interventions demonstrated a significant MEP interaction both in the stimulated pharyngeal cortex (F (4, 56) = 1.731, p = 0.038) and in the ipsilateral thenar cortex (F (4, 56) = 1.506, p = 0.048). Compared to sham, subsequent post hoc tests showed site-specific and sustained (60-120 min) increases in PMEPs with gamma tACS and tRNS (p = 0.005, p = 0.027, respectively) and for TMEPs with beta tACS (p = 0.006). CONCLUSIONS AND INFERENCES Our findings suggest that the effects of tACS and tRNS are frequency-dependent and cortical (representation) site-specific with both gamma tACS and full-spectrum tRNS enhancing human pharyngeal cortical excitability. These techniques hold promise as potential treatments for neurological dysphagia.
Collapse
Affiliation(s)
- Mengqing Zhang
- Department of Rehabilitation Medicine, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.,Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health, Centre for Gastrointestinal Sciences, Clinical Sciences Building, Salford Royal NHS Foundation Trust, School of Medical Sciences, The University of Manchester, Manchester, UK
| | - Ivy Cheng
- Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health, Centre for Gastrointestinal Sciences, Clinical Sciences Building, Salford Royal NHS Foundation Trust, School of Medical Sciences, The University of Manchester, Manchester, UK
| | - Ayodele Sasegbon
- Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health, Centre for Gastrointestinal Sciences, Clinical Sciences Building, Salford Royal NHS Foundation Trust, School of Medical Sciences, The University of Manchester, Manchester, UK
| | - Zulin Dou
- Department of Rehabilitation Medicine, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Shaheen Hamdy
- Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health, Centre for Gastrointestinal Sciences, Clinical Sciences Building, Salford Royal NHS Foundation Trust, School of Medical Sciences, The University of Manchester, Manchester, UK
| |
Collapse
|
13
|
Ghin F, O'Hare L, Pavan A. Electrophysiological aftereffects of high-frequency transcranial random noise stimulation (hf-tRNS): an EEG investigation. Exp Brain Res 2021; 239:2399-2418. [PMID: 34105019 PMCID: PMC8354881 DOI: 10.1007/s00221-021-06142-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 05/24/2021] [Indexed: 12/02/2022]
Abstract
There is evidence that high-frequency transcranial random noise stimulation (hf-tRNS) is effective in improving behavioural performance in several visual tasks. However, so far there has been limited research into the spatial and temporal characteristics of hf-tRNS-induced facilitatory effects. In the present study, electroencephalogram (EEG) was used to investigate the spatial and temporal dynamics of cortical activity modulated by offline hf-tRNS on performance on a motion direction discrimination task. We used EEG to measure the amplitude of motion-related VEPs over the parieto-occipital cortex, as well as oscillatory power spectral density (PSD) at rest. A time-frequency decomposition analysis was also performed to investigate the shift in event-related spectral perturbation (ERSP) in response to the motion stimuli between the pre- and post-stimulation period. The results showed that the accuracy of the motion direction discrimination task was not modulated by offline hf-tRNS. Although the motion task was able to elicit motion-dependent VEP components (P1, N2, and P2), none of them showed any significant change between pre- and post-stimulation. We also found a time-dependent increase of the PSD in alpha and beta bands regardless of the stimulation protocol. Finally, time-frequency analysis showed a modulation of ERSP power in the hf-tRNS condition for gamma activity when compared to pre-stimulation periods and Sham stimulation. Overall, these results show that offline hf-tRNS may induce moderate aftereffects in brain oscillatory activity.
Collapse
Affiliation(s)
- Filippo Ghin
- School of Psychology, University of Lincoln, Brayford Wharf East, Lincoln, LN5 7AY, UK.
- Cognitive Neurophysiology, Department of Child and Adolescent Psychiatry, Faculty of Medicine of the TU Dresden, Fetscherstraße 74, Schubertstraße 42, 01309, Dresden, Germany.
| | - Louise O'Hare
- School of Psychology, University of Lincoln, Brayford Wharf East, Lincoln, LN5 7AY, UK
- Division of Psychology, Nottingham Trent University, 50 Shakespeare Street, Nottingham, NG1 4FQ, UK
| | - Andrea Pavan
- School of Psychology, University of Lincoln, Brayford Wharf East, Lincoln, LN5 7AY, UK
- Department of Psychology, University of Bologna, Viale Berti Pichat, 5, 40127, Bologna, Italy
| |
Collapse
|
14
|
Hoshi H, Kojima S, Otsuru N, Onishi H. Effects of transcranial random noise stimulation timing on corticospinal excitability and motor function. Behav Brain Res 2021; 414:113479. [PMID: 34302882 DOI: 10.1016/j.bbr.2021.113479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 07/07/2021] [Accepted: 07/21/2021] [Indexed: 10/20/2022]
Abstract
Although transcranial random noise stimulation (tRNS) to the primary motor cortex (M1) increases corticospinal excitability and improves motor function, the effects of tRNS timing have not been clarified when combined with motor training. The purpose of this study was to clarify the effects of different tRNS timing on corticospinal excitability and motor function. We applied tRNS to the left M1 using a frequency of 0.1-640 Hz for 10 min to 15 healthy subjects. Subjects performed visuomotor tracking tasks with right hand for 10 min and participated in the following four conditions based on the timing of tRNS: (1) "before" condition, tRNS was performed before motor training; (2) "during" condition, tRNS was performed during motor training; (3) "after" condition, tRNS was performed after motor training; and (4) sham condition, the control group. Motor evoked potential (MEP) amplitudes were recorded from the right first dorsal interosseous muscle using transcranial magnetic stimulation. MEP amplitudes were assessed by baseline followed by three sessions at 10 min intervals. The motor function was assessed before and after tRNS and motor training. The MEP amplitude increased after tRNS in the before and during conditions but not in the after condition. Motor function after motor training improved in all conditions, but there were no significant differences between these conditions. The present study revealed that the timing of tRNS affects corticospinal excitability but not motor learning.
Collapse
Affiliation(s)
- Haruki Hoshi
- Graduate School of Health and Welfare, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata-City, Niigata 950-3198, Japan; TMG Asaka Medical Center, 1340-1 Mizonuma, Asaka-City, Saitama 351-0023, Japan.
| | - Sho Kojima
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata-City, Niigata 950-3198, Japan.
| | - Naofumi Otsuru
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata-City, Niigata 950-3198, Japan.
| | - Hideaki Onishi
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-Ku, Niigata-City, Niigata 950-3198, Japan.
| |
Collapse
|
15
|
Determining the optimal pulse number for theta burst induced change in cortical excitability. Sci Rep 2021; 11:8726. [PMID: 33888752 PMCID: PMC8062542 DOI: 10.1038/s41598-021-87916-2] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/06/2021] [Indexed: 12/19/2022] Open
Abstract
Theta-burst stimulation (TBS) is a form of non-invasive neuromodulation which is delivered in an intermittent (iTBS) or continuous (cTBS) manner. Although 600 pulses is the most common dose, the goal of these experiments was to evaluate the effect of higher per-dose pulse numbers on cortical excitability. Sixty individuals were recruited for 2 experiments. In Experiment 1, participants received 600, 1200, 1800, or sham (600) iTBS (4 visits, counterbalanced, left motor cortex, 80% active threshold). In Experiment 2, participants received 600, 1200, 1800, 3600, or sham (600) cTBS (5 visits, counterbalanced). Motor evoked potentials (MEP) were measured in 10-min increments for 60 min. For iTBS, there was a significant interaction between dose and time (F = 3.8296, p = 0.01), driven by iTBS (1200) which decreased excitability for up to 50 min (t = 3.1267, p = 0.001). For cTBS, there was no overall interaction between dose and time (F = 1.1513, p = 0.33). Relative to sham, cTBS (3600) increased excitability for up to 60 min (t = 2.0880, p = 0.04). There were no other significant effects of dose relative to sham in either experiment. Secondary analyses revealed high within and between subject variability. These results suggest that iTBS (1200) and cTBS (3600) are, respectively, the most effective doses for decreasing and increasing cortical excitability.
Collapse
|
16
|
Brambilla M, Dinkelbach L, Bigler A, Williams J, Zokaei N, Cohen Kadosh R, Brem AK. The Effect of Transcranial Random Noise Stimulation on Cognitive Training Outcome in Healthy Aging. Front Neurol 2021; 12:625359. [PMID: 33767658 PMCID: PMC7985554 DOI: 10.3389/fneur.2021.625359] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 02/09/2021] [Indexed: 12/20/2022] Open
Abstract
Background and Objective: Aging is associated with a decline in attentional and executive abilities, which are linked to physiological, structural, and functional brain changes. A variety of novel non-invasive brain stimulation methods have been probed in terms of their neuroenhancement efficacy in the last decade; one that holds significant promise is transcranial random noise stimulation (tRNS) that delivers an alternate current at random amplitude and frequency. The aim of this study was to investigate whether repeated sessions of tRNS applied as an add-on to cognitive training (CT) may induce long-term near and far transfer cognitive improvements. Methods: In this sham-controlled, randomized, double-blinded study forty-two older adults (age range 60-86 years) were randomly assigned to one of three intervention groups that received 20 min of 0.705 mA tRNS (N = 14), 1 mA tRNS (N = 14), or sham tRNS (N = 19) combined with 30 min of CT of executive functions (cognitive flexibility, inhibitory control, working memory). tRNS was applied bilaterally over the dorsolateral prefrontal cortices for five sessions. The primary outcome (non-verbal logical reasoning) and other cognitive functions (attention, memory, executive functions) were assessed before and after the intervention and at a 1-month follow-up. Results: Non-verbal logical reasoning, inhibitory control and reaction time improved significantly over time, but stimulation did not differentially affect this improvement. These changes occurred during CT, while no further improvement was observed during follow-up. Performance change in logical reasoning was significantly correlated with age in the group receiving 1 mA tRNS, indicating that older participants profited more from tRNS than younger participants. Performance change in non-verbal working memory was significantly correlated with age in the group receiving sham tRNS, indicating that in contrast to active tRNS, older participants in the sham group declined more than younger participants. Interpretation: CT induced cognitive improvements in all treatment groups, but tRNS did not modulate most of these cognitive improvements. However, the effect of tRNS depended on age in some cognitive functions. We discuss possible explanations leading to this result that can help to improve the design of future neuroenhancement studies in older populations.
Collapse
Affiliation(s)
- Michela Brambilla
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
- Biomedical and Clinical Sciences Department, Center for Research and Treatment on Cognitive Dysfunctions, “Luigi Sacco” Hospital, University of Milan, Milan, Italy
| | - Lars Dinkelbach
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
- Department of Neurology, Institute of Clinical Neuroscience and Medical Psychology, Heinrich Heine University, Duesseldorf, Germany
| | - Annelien Bigler
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
- Department of Experimental Psychology, Ghent University, Ghent, Belgium
| | - Joseph Williams
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
- Medical Sciences Division, University of Oxford, Oxford, United Kingdom
| | - Nahid Zokaei
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
| | - Roi Cohen Kadosh
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
| | - Anna-Katharine Brem
- Department of Experimental Psychology, University of Oxford, Oxford, United Kingdom
- Department of Neurology, Berenson-Allen Center for Noninvasive Brain Stimulation and Division for Cognitive Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States
| |
Collapse
|
17
|
Schoisswohl S, Langguth B, Gebel N, Poeppl TB, Kreuzer PM, Schecklmann M. Electrophysiological evaluation of high and low-frequency transcranial random noise stimulation over the auditory cortex. PROGRESS IN BRAIN RESEARCH 2020; 263:95-108. [PMID: 34243893 DOI: 10.1016/bs.pbr.2020.08.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Transcranial random noise stimulation (tRNS) is a non-invasive brain stimulation technique which uses electrical alternating currents applied at random frequencies. Besides the ability to alter cortical excitability, past research demonstrated that high-frequency tRNS over the auditory cortex can modulate both spontaneous and auditory evoked oscillatory brain activity. OBJECTIVES The aim of the present study was to examine the effects of high- and low-frequency auditory tRNS on EEG power and evoked activity. METHODS Low-frequency (0.1-100Hz), high-frequency (100-640Hz) and sham tRNS were administered for a stimulation over the auditory cortex in 22 healthy subjects. Before and after tRNS stimulation auditory steady state responses (ASSR) of 20 and 40Hz stimuli as well as oscillatory brain activity were recorded with electroencephalography (EEG). RESULTS Stimulation of both verum tRNS protocols revealed no significant changes either in ASSR or in resting state EEG activity. Unexpectedly, sham tRNS resulted in a significant decrease in 20Hz ASSR and an increase in the alpha frequency band (8-12.5Hz). CONCLUSION We were not able to replicate previous findings of a modulation of resting state EEG activity and ASSR by tRNS.
Collapse
Affiliation(s)
- Stefan Schoisswohl
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany.
| | - Berthold Langguth
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Nikolaus Gebel
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Timm B Poeppl
- Department of Psychiatry, Psychotherapy and Psychosomatics, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
| | - Peter M Kreuzer
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Martin Schecklmann
- Department of Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| |
Collapse
|
18
|
Haeckert J, Lasser C, Pross B, Hasan A, Strube W. Comparative study of motor cortical excitability changes following anodal tDCS or high-frequency tRNS in relation to stimulation duration. Physiol Rep 2020; 8:e14595. [PMID: 32996722 PMCID: PMC7525483 DOI: 10.14814/phy2.14595] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 07/30/2020] [Accepted: 07/31/2020] [Indexed: 04/14/2023] Open
Abstract
BACKGROUND In this study, we investigate the capacity of two different non-invasive brain stimulation (NIBS) techniques (anodal transcranial direct current stimulation (anodal tDCS) and high-frequency transcranial random noise stimulation (hf-tRNS)) regarding the relationship between stimulation duration and their efficacy in inducing long-lasting changes in motor cortical excitability. METHODS Fifteen healthy subjects attended six experimental sessions (90 experiments in total) and underwent both anodal tDCS of 7, 13, and 20 min duration, as well as high-frequency 1mA-tRNS of 7, 13, and 20 min stimulation duration. Sessions were performed in a randomized order and subjects were blinded to the applied methods. RESULTS For anodal tDCS, no significant stable increases of motor cortical excitability were observed for either stimulation duration. In contrast, for hf -tRNS a stimulation duration of 7 min resulted in a significant increase of motor cortical excitability lasting from 20 to 60 min poststimulation. While an intermediate duration of 13 min hf-tRNS failed to induce lasting changes in motor cortical excitability, a longer stimulation duration of 20 min hf-tRNS led only to significant increases at 50 min poststimulation which did not outlast until 60 min poststimulation. CONCLUSION Hf-tRNS for a duration of 7 min induced robust increases of motor cortical excitability, suggesting an indirect proportional relationship between stimulation duration and efficacy. While hf-tRNS appeared superior to anodal tDCS in this study, further systematic and randomized experiments are necessary to evaluate the generalizability of our observations and to address current intensity as a further modifiable contributor to the variability of transcranial brain stimulation.
Collapse
Affiliation(s)
- Jan Haeckert
- Department of Psychiatry and PsychotherapyUniversity Hospital MunichMünchenGermany
| | - Christoph Lasser
- Department of Psychiatry and PsychotherapyUniversity Hospital MunichMünchenGermany
| | - Benjamin Pross
- Department of Psychiatry and PsychotherapyUniversity Hospital MunichMünchenGermany
| | - Alkomiet Hasan
- Department of Psychiatry and PsychotherapyUniversity Hospital MunichMünchenGermany
- Department of Psychiatry, Psychotherapy and Psychosomatics, Bezirkskrankenhaus AugsburgUniversity of AugsburgAugsburgGermany
| | - Wolfgang Strube
- Department of Psychiatry and PsychotherapyUniversity Hospital MunichMünchenGermany
- Department of Psychiatry, Psychotherapy and Psychosomatics, Bezirkskrankenhaus AugsburgUniversity of AugsburgAugsburgGermany
| |
Collapse
|
19
|
Monastero R, Baschi R, Nicoletti A, Pilati L, Pagano L, Cicero CE, Zappia M, Brighina F. Transcranial random noise stimulation over the primary motor cortex in PD-MCI patients: a crossover, randomized, sham-controlled study. J Neural Transm (Vienna) 2020; 127:1589-1597. [PMID: 32965593 PMCID: PMC7666273 DOI: 10.1007/s00702-020-02255-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 09/14/2020] [Indexed: 02/04/2023]
Abstract
Mild cognitive impairment (MCI) is a very common non-motor feature of Parkinson’s disease (PD) and the non-amnestic single-domain is the most frequent subtype. Transcranial random noise stimulation (tRNS) is a non-invasive technique, which is capable of enhancing cortical excitability. As the main contributor to voluntary movement control, the primary motor cortex (M1) has been recently reported to be involved in higher cognitive functioning. The aim of this study is to evaluate the effects of tRNS applied over M1 in PD-MCI patients in cognitive and motor tasks. Ten PD-MCI patients, diagnosed according to the Movement Disorder Society, Level II criteria for MCI, underwent active (real) and placebo (sham) tRNS single sessions, at least 1 week apart. Patients underwent cognitive (Digit Span Forward and Backward, Digit Symbol, Visual Search, Letter Fluency, Stroop Test) and motor assessments (Unified Parkinson’s Disease Rating Scale [UPDRS-ME], specific timed trials for bradykinesia, 10-m walk and Timed up and go tests) before and after each session. A significant improvement in motor ability (UPDRS-ME and lateralized scores, ps from 0.049 to 0.003) was observed after real versus sham tRNS. On the contrary, no significant differences were found in other motor tasks and cognitive assessment both after real and sham stimulations. These results confirm that tRNS is a safe and effective tool for improving motor functioning in PD-MCI. Future studies using a multisession tRNS applied over multitargeted brain areas (i.e., dorsolateral prefrontal cortex and M1) are required to clarify the role of tRNS regarding rehabilitative intervention in PD.
Collapse
Affiliation(s)
- Roberto Monastero
- Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Via La Loggia 1, 90129, Palermo, Italy.
| | - Roberta Baschi
- Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Via La Loggia 1, 90129, Palermo, Italy
| | - Alessandra Nicoletti
- Department of Medical and Surgical Sciences and Advanced Technologies "G.F. Ingrassia", Section of Neurosciences, University of Catania, Catania, Italy
| | - Laura Pilati
- Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Via La Loggia 1, 90129, Palermo, Italy
| | - Lorenzo Pagano
- Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Via La Loggia 1, 90129, Palermo, Italy
| | - Calogero Edoardo Cicero
- Department of Medical and Surgical Sciences and Advanced Technologies "G.F. Ingrassia", Section of Neurosciences, University of Catania, Catania, Italy
| | - Mario Zappia
- Department of Medical and Surgical Sciences and Advanced Technologies "G.F. Ingrassia", Section of Neurosciences, University of Catania, Catania, Italy
| | - Filippo Brighina
- Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Via La Loggia 1, 90129, Palermo, Italy
| |
Collapse
|
20
|
Murphy O, Hoy K, Wong D, Bailey N, Fitzgerald P, Segrave R. Transcranial random noise stimulation is more effective than transcranial direct current stimulation for enhancing working memory in healthy individuals: Behavioural and electrophysiological evidence. Brain Stimul 2020; 13:1370-1380. [DOI: 10.1016/j.brs.2020.07.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 06/16/2020] [Accepted: 07/01/2020] [Indexed: 01/22/2023] Open
|
21
|
Bashir S, Ahmad S, Alatefi M, Hamza A, Sharaf M, Fecteau S, Yoo WK. Effects of anodal transcranial direct current stimulation on motor evoked potentials variability in humans. Physiol Rep 2020; 7:e14087. [PMID: 31301123 PMCID: PMC6640590 DOI: 10.14814/phy2.14087] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/01/2019] [Accepted: 04/02/2019] [Indexed: 12/24/2022] Open
Abstract
Motor evoked potentials (MEPs) obtained from transcranial magnetic stimulation (TMS) allow corticospinal excitability (CSE) to be measured in the human primary motor cortex (M1). CSE responses to transcranial direct current stimulation (tDCS) protocols are highly variable. Here, we tested the reproducibility and reliability of individual MEPs following a common anodal tDCS protocol. In this study, 32 healthy subjects received anodal tDCS stimulation over the left M1 for three durations (tDCS‐T5, tDCS‐T10, and tDCS‐T20 min) on separate days in a crossover‐randomized order. After the resting motor threshold (RMT) was determined for the contralateral first dorsal interosseous muscle, 15 single pulses 4–8 sec apart at an intensity of 120% RMT were delivered to the left M1 to determine the baseline MEP amplitude at T0, T5, T10, T20, T30, T40, T50, and T60 min after stimulation for each durations. During TMS delivery, 3D images of the participant's cortex and hot spot were visualized for obtaining MEPs from same position. Our findings revealed that there was a significant MEPs improvement at T0 (P = 0.01) after 10 min of anodal stimulation. After the 20‐min stimulation duration, MEPs differed specifically at T0, T5, T30 min (P < 0.05). This indicates that tDCS is a promising tool to improve MEPs. Our observed variability in response to the tDCS protocol is consistent with other noninvasive brain stimulation studies.
Collapse
Affiliation(s)
- Shahid Bashir
- Neuroscience Center, King Fahad Specialist Hospital Dammam, Dammam, Saudi Arabia
| | - Shafiq Ahmad
- Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia
| | - Moath Alatefi
- Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia
| | - Ali Hamza
- Department of Electrical Engineering, National University of Computer and Emerging Sciences, Lahore, Pakistan
| | - Mohamed Sharaf
- Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia
| | | | - Woo Kyoung Yoo
- Department of Physical Medicine and Rehabilitation, Hallym University Sacred Heart Hospital, Anyang, South Korea.,Hallym Institute for Translational Genomics & Bioinformatics, Hallym University Sacred Heart Hospital, Anyang, South Korea
| |
Collapse
|
22
|
Bashir S, Aisha D, Hamza A, Al-Hussain F, Yoo WK. Effects of transcranial direct current stimulation on cortex modulation by stimulation of the primary motor cortex and parietal cortex in humans. Int J Neurosci 2020; 131:1107-1114. [PMID: 32462947 DOI: 10.1080/00207454.2020.1775594] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
AIM OF THE STUDY Transcranial magnetic stimulation (TMS) is used to measure corticospinal excitability (CSE) from the primary motor cortex (M1) in humans through motor-evoked potentials (MEPs). The variability of CSE responses to transcranial direct current stimulation (tDCS) protocols is high and needs to be reproduced in the healthy population. The M1 and posterior parietal cortex (PPC) are anatomically and functionally connected and could play a role in understanding the variability in CSE responses. We tested the individual MEPs following a common cathodal (ctDCS) protocol over the M1 and PPC. MATERIALS AND METHODS Twenty-eight healthy subjects were randomized for a ctDCS stimulation over the left M1 and PPC for 20 min on a separate days. The first dorsal interosseous muscle (FDI) contralateral stimulation of the left M1 was used as the resting motor threshold (RMT), while 15 single pulses 4-8 s apart at an intensity of 120% RMT were used to determine the baseline MEP amplitude and at T0, 5, 10, 20, 30, 40, 50, and 60 min after ctDCS stimulation in both sessions. RESULTS A 20 min duration of ctDCS stimulation significantly deceased the CSE only at T0 (p = 0.046 at M1, p = 0.010 at PPC). CONCLUSION Our results suggested that PPC stimulation can modulate M1 excitability and PPC-M1 connectivity, but a significant effect is only observed immediately post ctDCS. The tDCS showed variability in response to the tDCS protocol is consistent with other non-invasive brain stimulation studies.
Collapse
Affiliation(s)
- Shahid Bashir
- Neuroscience Center, King Fahad Specialist Hospital Dammam, Dammam, Saudi Arabia
| | - Dowihi Aisha
- Neuroscience Center, King Fahad Specialist Hospital Dammam, Dammam, Saudi Arabia
| | - Ali Hamza
- Department of Electrical Engineering, National University of Computer and Emerging Sciences, Lahore, Pakistan
| | - Fawaz Al-Hussain
- Division of Neurology, College of Medicine, King Saud University, Riyadh, Saudi Arabia
| | - Woo-Kyoung Yoo
- Department of Physical Medicine and Rehabilitation, Hallym University College of Medicine, Anyang, South Korea.,Department of Physical Medicine and Rehabilitation, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea
| |
Collapse
|
23
|
Nikolin S, Alonzo A, Martin D, Gálvez V, Buten S, Taylor R, Goldstein J, Oxley C, Hadzi-Pavlovic D, Loo CK. Transcranial Random Noise Stimulation for the Acute Treatment of Depression: A Randomized Controlled Trial. Int J Neuropsychopharmacol 2020; 23:146-156. [PMID: 31899509 PMCID: PMC7171931 DOI: 10.1093/ijnp/pyz072] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 11/27/2019] [Accepted: 12/31/2019] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Transcranial electrical stimulation has broad potential as a treatment for depression. Transcranial random noise stimulation, which delivers randomly fluctuating current intensities, may have greater cortical excitatory effects compared with other forms of transcranial electrical stimulation. We therefore aimed to investigate the antidepressant efficacy of transcranial random noise stimulation. METHODS Depressed participants were randomly assigned by computer number generator to receive 20 sessions of either active or sham transcranial random noise stimulation over 4 weeks in a double-blinded, parallel group randomized-controlled trial. Transcranial random noise stimulation was delivered for 30 minutes with a direct current offset of 2 mA and a random noise range of 2 mA. Primary analyses assessed changes in depression severity using the Montgomery-Asperg Depression Rating Scale. Neuroplasticity, neuropsychological, and safety outcomes were analyzed as secondary measures. RESULTS Sixty-nine participants were randomized, of which 3 discontinued treatment early, leaving 66 (sham n = 34, active n = 32) for per-protocol analysis. Depression severity scores reduced in both groups (Montgomery-Asperg Depression Rating Scale reduction in sham = 7.0 [95% CI = 5.0-8.9]; and active = 5.2 [95% CI = 3.2-7.3]). However, there were no differences between active and sham groups in the reduction of depressive symptoms or the number of participants meeting response (sham = 14.7%; active = 3.1%) and remission criteria (sham = 5.9%; active = 0%). Erythema, paresthesia, fatigue, and dizziness/light-headedness occurred more frequently in the active transcranial random noise stimulation group. Neuroplasticity, neuropsychological, and acute cognitive effects were comparable between groups. CONCLUSION Our results do not support the use of transcranial random noise stimulation with the current stimulation parameters as a therapeutic intervention for the treatment of depression. CLINICAL TRIAL REGISTRATION AT CLINICALTRIALS gov/NCT01792414.
Collapse
Affiliation(s)
- Stevan Nikolin
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Black Dog Institute, Sydney, Australia
| | - Angelo Alonzo
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Black Dog Institute, Sydney, Australia
| | - Donel Martin
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Black Dog Institute, Sydney, Australia
| | - Veronica Gálvez
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Mental Health Department, Parc Taulí University Hospital, Institut d’Investigació I Innovació Sanitària Parc Taulí (I3PT), Barcelona, Spain
| | - Sara Buten
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Prince of Wales Hospital, Sydney, Australia
| | - Rohan Taylor
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Concord Centre for Mental Health, Concord, Australia
| | | | - Cristal Oxley
- Department of Child and Adolescent Psychiatry, Michael Rutter Centre – South London and Maudsley NHS Foundation Trust, UK
| | | | - Colleen K Loo
- School of Psychiatry, University of New South Wales, Sydney, Australia
- Black Dog Institute, Sydney, Australia
- St. George Hospital, Sydney, Australia
| |
Collapse
|
24
|
Mioni G, Grondin S, Bardi L, Stablum F. Understanding time perception through non-invasive brain stimulation techniques: A review of studies. Behav Brain Res 2020; 377:112232. [DOI: 10.1016/j.bbr.2019.112232] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 09/06/2019] [Accepted: 09/11/2019] [Indexed: 01/08/2023]
|
25
|
Zewdie E, Ciechanski P, Kuo HC, Giuffre A, Kahl C, King R, Cole L, Godfrey H, Seeger T, Swansburg R, Damji O, Rajapakse T, Hodge J, Nelson S, Selby B, Gan L, Jadavji Z, Larson JR, MacMaster F, Yang JF, Barlow K, Gorassini M, Brunton K, Kirton A. Safety and tolerability of transcranial magnetic and direct current stimulation in children: Prospective single center evidence from 3.5 million stimulations. Brain Stimul 2019; 13:565-575. [PMID: 32289678 DOI: 10.1016/j.brs.2019.12.025] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/20/2019] [Accepted: 12/23/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Non-invasive brain stimulation is being increasingly used to interrogate neurophysiology and modulate brain function. Despite the high scientific and therapeutic potential of non-invasive brain stimulation, experience in the developing brain has been limited. OBJECTIVE To determine the safety and tolerability of non-invasive neurostimulation in children across diverse modalities of stimulation and pediatric populations. METHODS A non-invasive brain stimulation program was established in 2008 at our pediatric, academic institution. Multi-disciplinary neurophysiological studies included single- and paired-pulse Transcranial Magnetic Stimulation (TMS) methods. Motor mapping employed robotic TMS. Interventional trials included repetitive TMS (rTMS) and transcranial direct current stimulation (tDCS). Standardized safety and tolerability measures were completed prospectively by all participants. RESULTS Over 10 years, 384 children underwent brain stimulation (median 13 years, range 0.8-18.0). Populations included typical development (n = 118), perinatal stroke/cerebral palsy (n = 101), mild traumatic brain injury (n = 121) neuropsychiatric disorders (n = 37), and other (n = 7). No serious adverse events occurred. Drop-outs were rare (<1%). No seizures were reported despite >100 participants having brain injuries and/or epilepsy. Tolerability between single and paired-pulse TMS (542340 stimulations) and rTMS (3.0 million stimulations) was comparable and favourable. TMS-related headache was more common in perinatal stroke (40%) than healthy participants (13%) but was mild and self-limiting. Tolerability improved over time with side-effect frequency decreasing by >50%. Robotic TMS motor mapping was well-tolerated though neck pain was more common than with manual TMS (33% vs 3%). Across 612 tDCS sessions including 92 children, tolerability was favourable with mild itching/tingling reported in 37%. CONCLUSIONS Standard non-invasive brain stimulation paradigms are safe and well-tolerated in children and should be considered minimal risk. Advancement of applications in the developing brain are warranted. A new and improved pediatric NIBS safety and tolerability form is included.
Collapse
Affiliation(s)
- E Zewdie
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
| | - P Ciechanski
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - H C Kuo
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - A Giuffre
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - C Kahl
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - R King
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - L Cole
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - H Godfrey
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - T Seeger
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - R Swansburg
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - O Damji
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - T Rajapakse
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - J Hodge
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - S Nelson
- Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - B Selby
- Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - L Gan
- Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Z Jadavji
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - J R Larson
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - F MacMaster
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - J F Yang
- Department of Physical Therapy, University of Alberta, Edmonton, Alberta, Canada
| | - K Barlow
- Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - M Gorassini
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - K Brunton
- Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada
| | - A Kirton
- Calgary Pediatric Stroke Program, University of Calgary, Calgary, Alberta, Canada; Departments of Pediatrics and Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada; Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada; Department of Neurosciences, University of Calgary, Calgary, Alberta, Canada; Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
26
|
Transcranial random noise stimulation (tRNS): a wide range of frequencies is needed for increasing cortical excitability. Sci Rep 2019; 9:15150. [PMID: 31641235 PMCID: PMC6806007 DOI: 10.1038/s41598-019-51553-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 10/02/2019] [Indexed: 11/28/2022] Open
Abstract
Transcranial random noise stimulation (tRNS) is a recent neuromodulation protocol. The high-frequency band (hf-tRNS) has shown to be the most effective in enhancing neural excitability. The frequency band of hf-tRNS typically spans from 100 to 640 Hz. Here we asked whether both the lower and the higher half of the high-frequency band are needed for increasing neural excitability. Three frequency ranges (100–400 Hz, 400–700 Hz, 100–700 Hz) and Sham conditions were delivered for 10 minutes at an intensity of 1.5 mA over the primary motor cortex (M1). Single-pulse transcranial magnetic stimulation (TMS) was delivered over the same area at baseline, 0, 10, 20, 30, 45 and 60 minutes after stimulation, while motor evoked potentials (MEPs) were recorded to evaluate changes in cortical excitability. Only the full-band condition (100–700 Hz) was able to modulate excitability by enhancing MEPs at 10 and 20 minutes after stimulation: neither the higher nor the lower sub-range of the high-frequency band significantly modulated cortical excitability. These results show that the efficacy of tRNS is strictly related to the width of the selected frequency range.
Collapse
|
27
|
Albuquerque LLD, Fischer KM, Pauls AL, Pantovic M, Guadagnoli MA, Riley ZA, Poston B. An acute application of transcranial random noise stimulation does not enhance motor skill acquisition or retention in a golf putting task. Hum Mov Sci 2019; 66:241-248. [PMID: 31078943 DOI: 10.1016/j.humov.2019.04.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 04/30/2019] [Accepted: 04/30/2019] [Indexed: 11/18/2022]
Abstract
Transcranial random noise stimulation (tRNS) is a brain stimulation technique that has been shown to increase motor performance in simple motor tasks. The purpose was to determine the influence of tRNS on motor skill acquisition and retention in a complex golf putting task. Thirty-four young adults were randomly assigned to a tRNS group or a SHAM stimulation group. Each subject completed a practice session followed by a retention session. In the practice session, subjects performed golf putting trials in a baseline test block, four practice blocks, and a post test block. Twenty-four hours later subjects completed the retention test block. The golf putting task involved performing putts to a small target located 3 m away. tRNS or SHAM was applied during the practice blocks concurrently with the golf putting task. tRNS was applied over the first dorsal interosseus muscle representation area of the motor cortex for 20 min at a current strength of 2 mA. Endpoint error and endpoint variance were reduced across the both the practice blocks and the test blocks, but these reductions were not different between groups. These findings suggest that an acute application of tRNS failed to enhance skill acquisition or retention in a golf putting task.
Collapse
Affiliation(s)
- Lidio Lima de Albuquerque
- Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV, USA
| | - Katherine M Fischer
- Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV, USA
| | - Aaron L Pauls
- Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV, USA
| | - Milan Pantovic
- Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV, USA
| | - Mark A Guadagnoli
- School of Medicine, University of Nevada Las Vegas, Las Vegas, NV, USA
| | - Zachary A Riley
- Department of Kinesiology, Indiana University Purdue University Indianapolis, Indianapolis, IN, USA
| | - Brach Poston
- Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV, USA.
| |
Collapse
|
28
|
Brighina F, Curatolo M, Cosentino G, De Tommaso M, Battaglia G, Sarzi-Puttini PC, Guggino G, Fierro B. Brain Modulation by Electric Currents in Fibromyalgia: A Structured Review on Non-invasive Approach With Transcranial Electrical Stimulation. Front Hum Neurosci 2019; 13:40. [PMID: 30804771 PMCID: PMC6378756 DOI: 10.3389/fnhum.2019.00040] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 01/24/2019] [Indexed: 01/13/2023] Open
Abstract
Fibromyalgia syndrome (FMS) is a complex disorder where widespread musculoskeletal pain is associated with many heterogenous symptoms ranging from affective disturbances to cognitive dysfunction and central fatigue. FMS is currently underdiagnosed and often very poorly responsive to pharmacological treatment. Pathophysiology of the disease remains still obscure even if in the last years fine structural and functional cerebral abnormalities have been identified, principally by neurophysiological and imaging studies delineating disfunctions in pain perception, processing and control systems. On such basis, recently, neurostimulation of brain areas involved in mechanism of pain processing and control (primary motor cortex: M1 and dorsolateral prefrontal cortex: DLPFC) has been explored by means of different approaches and particularly through non-invasive brain stimulation techniques (transcranial magnetic and electric stimulation: TMS and tES). Here we summarize studies on tES application in FMS. The great majority of reports, based on direct currents (transcranial direct currents stimulation: tDCS) and targeting M1, showed efficacy on pain measures and less on cognitive and affective symptoms, even if several aspects as maintenance of therapeutical effects and optimal stimulation parameters remain to be established. Differently, stimulation of DLPFC, explored in a few studies, was ineffective on pain and showed limited effects on cognitive and affective symptoms. Very recently new tES techniques as high-density tDCS (HD-tDCS), transcranial random noise stimulation (tRNS) and tDCS devices for home-based treatment have been explored in FMS with interesting even if very preliminary results opening interesting perspectives for more effective, well tolerated, cheap and easy therapeutic approaches.
Collapse
Affiliation(s)
- Filippo Brighina
- Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata (BIND), Università degli Studi di Palermo, Palermo, Italy
| | - Massimiliano Curatolo
- Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata (BIND), Università degli Studi di Palermo, Palermo, Italy
| | - Giuseppe Cosentino
- Department of Brain and Behavioral Sciences, University of Pavia, Pavia, Italy.,IRCCS Mondino Foundation, Pavia, Italy
| | - Marina De Tommaso
- Unità di Neurofisiopatologia del Dolore, Dipartimento di Scienze Mediche di Base, Neuroscienze e Organi di Senso (SMBNOS), Università degli Studi di Bari Aldo Moro, Bari, Italy
| | - Giuseppe Battaglia
- Dipartimento di Scienze Psicologiche, Pedagogiche, dell'Esercizio Fisico e della Formazione, Università degli Studi di Palermo, Palermo, Italy
| | | | - Giuliana Guggino
- Dipartimento Biomedico di Medicina Interna e Specialistica (DIBIMIS), Università degli Studi di Palermo, Palermo, Italy
| | - Brigida Fierro
- Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata (BIND), Università degli Studi di Palermo, Palermo, Italy
| |
Collapse
|
29
|
Qi F, Nitsche MA, Zschorlich VR. Interaction Between Transcranial Random Noise Stimulation and Observation-Execution Matching Activity Promotes Motor Cortex Excitability. Front Neurosci 2019; 13:69. [PMID: 30792626 PMCID: PMC6374348 DOI: 10.3389/fnins.2019.00069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 01/23/2019] [Indexed: 12/29/2022] Open
Abstract
Pathways of the human mirror neuron system are activated during both, action observation and action execution, including lateralized activation of respective areas, as shown by observed right-or left-hand actions. Here, we investigated whether execution-dependent motor cortex excitability is affected by prior interaction between transcranial random noise stimulation (tRNS) and action observation. Sham or real tRNS (1 mA) was applied for 10-min over the left primary motor cortex during action observation. In the main experiments, participants received sham or real tRNS while they watched a video showing repeated tapping tasks, involving either the right-hand (Experiment 1, congruent action observation), or a mirror-reversed video showing the same performance (Experiment 2), followed by action execution of the right-hand. In control Experiments 1–3, participants received real tRNS while observing a perceptual sequence, watching a landscape picture, or observing the left-hand performing the action (the sequence was identical to Experiment 1), followed by action execution of the right-hand. In control Experiment 4, participants received real tRNS during congruent action observation, and then took 6-min rest. Motor-evoked potentials (MEP) were recorded before action observation, a perceptual sequence or a landscape picture, immediately after, and after action execution, or an interval of 6-min, dependent on the respective experimental condition. MEPs in the right first dorsal interosseous muscle increased significantly after real tRNS combined with congruent action observation, and after action execution compared to the sham session in Experiment 1 and control experiments. We conclude that prior interaction between real tRNS and action observation of mirror-matched movements modulates subsequent execution-dependent motor cortex excitability.
Collapse
Affiliation(s)
- Fengxue Qi
- Department of Movement Science, Faculty of Philosophy, University of Rostock, Rostock, Germany.,Department of Psychology and Neurosciences, Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany
| | - Michael A Nitsche
- Department of Psychology and Neurosciences, Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany.,Department of Neurology, University Medical Hospital Bergmannsheil, Bochum, Germany
| | - Volker R Zschorlich
- Department of Movement Science, Faculty of Philosophy, University of Rostock, Rostock, Germany.,Faculty of Medicine, University of Rostock, Rostock, Germany.,Department Ageing of Individuals and Society, Faculty of Interdisciplinary Research, University of Rostock, Rostock, Germany
| |
Collapse
|
30
|
Pobric G, Hulleman J, Lavidor M, Silipo G, Rohrig S, Dias E, Javitt DC. Seeing the World as it is: Mimicking Veridical Motion Perception in Schizophrenia Using Non-invasive Brain Stimulation in Healthy Participants. Brain Topogr 2018; 31:827-837. [PMID: 29516204 PMCID: PMC6097741 DOI: 10.1007/s10548-018-0639-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Accepted: 02/26/2018] [Indexed: 11/06/2022]
Abstract
Schizophrenia (Sz) is a mental health disorder characterized by severe cognitive, emotional, social, and perceptual deficits. Visual deficits are found in tasks relying on the magnocellular/dorsal stream. In our first experiment we established deficits in global motion processing in Sz patients compared to healthy controls. We used a novel task in which background optic flow produces a distortion of the apparent trajectory of a moving stimulus, leading control participants to provide biased estimates of the true motion trajectory under conditions of global stimulation. Sz patients were significantly less affected by the global background motion, and reported trajectories that were more veridically accurate than those of controls. In order to study the mechanism of this effect, we performed a second experiment where we applied transcranial electrical stimulation over area MT+ to selectively modify global motion processing of optic flow displays in healthy participants. Cathodal and high frequency random noise stimulation had opposite effects on trajectory perception in optic flow. The brain stimulation over a control site and in a control task revealed that the effect of stimulation was specific for global motion processing in area MT+. These findings both support prior studies of impaired early visual processing in Sz and provide novel approaches for measurement and manipulation of the underlying circuits.
Collapse
Affiliation(s)
- Gorana Pobric
- Neuroscience and Aphasia Research Unit, Division of Neuroscience and Experimental Psychology, University of Manchester, Oxford Road, Manchester, M13 9PL, UK.
- Schizophrenia Research Division, Nathan Kline Institute, Orangeburg, NY, 10962, USA.
| | - Johan Hulleman
- Neuroscience and Aphasia Research Unit, Division of Neuroscience and Experimental Psychology, University of Manchester, Oxford Road, Manchester, M13 9PL, UK
| | - Michal Lavidor
- Department of Psychology, Bar Ilan University, Ramat Gan, Tel Aviv, Israel
| | - Gail Silipo
- Schizophrenia Research Division, Nathan Kline Institute, Orangeburg, NY, 10962, USA
| | - Stephanie Rohrig
- Schizophrenia Research Division, Nathan Kline Institute, Orangeburg, NY, 10962, USA
| | - Elisa Dias
- Schizophrenia Research Division, Nathan Kline Institute, Orangeburg, NY, 10962, USA
| | - Daniel C Javitt
- Schizophrenia Research Division, Nathan Kline Institute, Orangeburg, NY, 10962, USA
- Division of Experimental Therapeutics, Department of Psychiatry, Columbia University Medical Center, New York, NY, 10032, USA
| |
Collapse
|
31
|
Ghin F, Pavan A, Contillo A, Mather G. The effects of high-frequency transcranial random noise stimulation (hf-tRNS) on global motion processing: An equivalent noise approach. Brain Stimul 2018; 11:1263-1275. [PMID: 30078542 DOI: 10.1016/j.brs.2018.07.048] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 07/13/2018] [Accepted: 07/17/2018] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND High frequency transcranial random noise stimulation (hf-tRNS) facilitates performance in several perceptual and cognitive tasks, however, little is known about the underlying modulatory mechanisms. OBJECTIVE In this study we compared the effects of hf-tRNS to those of anodal and cathodal tDCS in a global motion direction discrimination task. An equivalent noise (EN) paradigm was used to assess how hf-tRNS modulates the mechanisms underlying local and global motion processing. METHOD Motion coherence threshold and slope of the psychometric function were estimated using an 8AFC task in which observers had to discriminate the motion direction of a random dot kinematogram presented either in the left or right visual hemi-field. During the task hf-tRNS, anodal and cathodal tDCS were delivered over the left hMT+. In a subsequent experiment we implemented an EN paradigm in order to investigate the effects of hf-tRNS on the mechanisms involved in visual motion integration (i.e., internal noise and sampling). RESULTS hf-tRNS reduced the motion coherence threshold but did not affect the slope of the psychometric function, suggesting no modulation of stimulus discriminability. Anodal and cathodal tDCS did not produce any modulatory effects. EN analysis in the last experiment found that hf-tRNS modulates sampling but not internal noise, suggesting that hf-tRNS modulates the integration of local motion cues. CONCLUSION hf-tRNS interacts with the output neurons tuned to directions near to the directional signal, incrementing the signal-to-noise ratio and the pooling of local motion cues and thus increasing the sensitivity for global moving stimuli.
Collapse
Affiliation(s)
- Filippo Ghin
- University of Lincoln, School of Psychology, Brayford Wharf East, Lincoln LN5 7AY, United Kingdom.
| | - Andrea Pavan
- University of Lincoln, School of Psychology, Brayford Wharf East, Lincoln LN5 7AY, United Kingdom
| | - Adriano Contillo
- University of Ferrara, Dipartimento di Fisica e Scienze della Terra, Via Saragat 1, 44122 Ferrara, Italy
| | - George Mather
- University of Lincoln, School of Psychology, Brayford Wharf East, Lincoln LN5 7AY, United Kingdom
| |
Collapse
|
32
|
Mioni G, Grondin S, Mapelli D, Stablum F. A tRNS investigation of the sensory representation of time. Sci Rep 2018; 8:10364. [PMID: 29985432 PMCID: PMC6037735 DOI: 10.1038/s41598-018-28673-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 06/25/2018] [Indexed: 11/30/2022] Open
Abstract
The understanding of the mechanisms underlying the representation of temporal intervals in the range of milliseconds/seconds remains a complex issue. Different brain areas have been identified as critical in temporal processing. The activation of specific areas is depending on temporal range involved in the tasks and on the modalities used for marking time. Here, for the first time, transcranial random noise stimulation (tRNS) was applied over the right posterior parietal (P4) and right frontal (F4) cortex to investigate their role in intra- and intermodal temporal processing involving brief temporal intervals (<1 sec). Eighty University students performed a time bisection task involving standard durations lasting 300 ms (short) and 900 ms (long). Each empty interval to be judged was marked by two successive brief visual (V) or auditory (A) signals defining four conditions: VV, VA, AV or AA. Participants were assigned to one of these four conditions. Half of the participants received tRNS over P4 and half over F4. No effect of stimulation was observed on temporal variability (Weber ratio). However, participants that were stimulated over P4 overestimated temporal intervals in the random condition compared to the sham condition. In addition to showing an effect of tRNS on perceived duration rather than on temporal variability, the results of the present study confirm that the right posterior parietal cortex is involved in the processing of time intervals and extend this finding to several sensory modality conditions.
Collapse
Affiliation(s)
- G Mioni
- Dipartimento di Psicologia Generale, Università di Padova, Padova, Italy.
| | - S Grondin
- École de Psychologie, Université Laval, Québec, Canada
| | - D Mapelli
- Dipartimento di Psicologia Generale, Università di Padova, Padova, Italy
| | - F Stablum
- Dipartimento di Psicologia Generale, Università di Padova, Padova, Italy
| |
Collapse
|
33
|
Inukai Y, Masaki M, Otsuru N, Saito K, Miyaguchi S, Kojima S, Onishi H. Effect of noisy galvanic vestibular stimulation in community-dwelling elderly people: a randomised controlled trial. J Neuroeng Rehabil 2018; 15:63. [PMID: 29970144 PMCID: PMC6029379 DOI: 10.1186/s12984-018-0407-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 06/19/2018] [Indexed: 11/29/2022] Open
Abstract
Background Balance disorders are a risk factor for falls in the elderly. Although noisy galvanic vestibular stimulation (nGVS) has been reported to improve balance in young people, randomised control trials targeting community-dwelling elderly people have not been conducted to date. We aimed to assess the influence of nGVS on COP sway in the open-eye standing posture among community-dwelling elderly people in a randomised controlled trial. Methods A randomised controlled trial of 32 community-dwelling elderly people randomly assigned to control (sham stimulation) and an nGVS groups. All participants underwent centre of pressure (COP) sway measurements while standing with open eyes at baseline and during stimulation. The control group underwent sham stimulation and the nGVS group underwent noise stimulation (0.4 mA; 0.1–640 Hz). Results In the nGVS group, sway path length, mediolateral mean velocity and anteroposterior mean velocity decreased during stimulation compared with baseline (P < 0.01). The effect of nGVS was large in participants with a high COP sway path length at baseline, but there was no significant difference in COP sway in the control group. Conclusions We conclude that nGVS decreases the COP sway path length and mean velocity of community-dwelling elderly people when standing with open eyes. This suggests that nGVS could be effective for treating balance dysfunction in the elderly.
Collapse
Affiliation(s)
- Yasuto Inukai
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan. .,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.
| | - Mitsuhiro Masaki
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| | - Naofumi Otsuru
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| | - Kei Saito
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| | - Shota Miyaguchi
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| | - Sho Kojima
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| | - Hideaki Onishi
- Department of Physical Therapy, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan.,Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata City, Niigata, Japan
| |
Collapse
|
34
|
Bieck SM, Artemenko C, Moeller K, Klein E. Low to No Effect: Application of tRNS During Two-Digit Addition. Front Neurosci 2018; 12:176. [PMID: 29674948 PMCID: PMC5895770 DOI: 10.3389/fnins.2018.00176] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Accepted: 03/05/2018] [Indexed: 01/02/2023] Open
Abstract
Transcranial electric stimulation such as transcranial random noise stimulation (tRNS) and transcranial direct current stimulation (tDCS) have been used to investigate structure-function relationships in numerical cognition. Recently, tRNS was suggested to be more effective than tDCS. However, so far there is no evidence on the differential impact of tDCS and tRNS on numerical cognition using the same experimental paradigm. In the present study, we used a two-digit addition paradigm for which significant-albeit small-effects of tDCS were observed previously to evaluate the impact of parietal and frontal tRNS on specific numerical effects. While previous studies reported a modulation of numerical effects of this task through tDCS applied to parietal areas, we did not observe any effect of parietal tRNS on performance in two-digit addition. These findings suggest that tRNS seemed to influence concurrent mental arithmetic less than tDCS at least when applied over the IPS. These generally small to absent effects of tES on actual arithmetic performance in the current addition paradigm are in line with the results of a recent meta-analysis indicating that influences of tES may be more pronounced in training paradigms.
Collapse
Affiliation(s)
- Silke M Bieck
- LEAD Graduate School & Research Network, University of Tuebingen, Tuebingen, Germany.,Leibniz-Institut für Wissensmedien, Tuebingen, Germany
| | - Christina Artemenko
- LEAD Graduate School & Research Network, University of Tuebingen, Tuebingen, Germany.,Department of Psychology, University of Tuebingen, Tuebingen, Germany
| | - Korbinian Moeller
- LEAD Graduate School & Research Network, University of Tuebingen, Tuebingen, Germany.,Leibniz-Institut für Wissensmedien, Tuebingen, Germany.,Department of Psychology, University of Tuebingen, Tuebingen, Germany
| | - Elise Klein
- Leibniz-Institut für Wissensmedien, Tuebingen, Germany
| |
Collapse
|
35
|
Huang YZ, Lu MK, Antal A, Classen J, Nitsche M, Ziemann U, Ridding M, Hamada M, Ugawa Y, Jaberzadeh S, Suppa A, Paulus W, Rothwell J. Plasticity induced by non-invasive transcranial brain stimulation: A position paper. Clin Neurophysiol 2017; 128:2318-2329. [DOI: 10.1016/j.clinph.2017.09.007] [Citation(s) in RCA: 198] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 08/31/2017] [Accepted: 09/05/2017] [Indexed: 12/11/2022]
|
36
|
Dissanayaka T, Zoghi M, Farrell M, Egan GF, Jaberzadeh S. Does transcranial electrical stimulation enhance corticospinal excitability of the motor cortex in healthy individuals? A systematic review and meta-analysis. Eur J Neurosci 2017; 46:1968-1990. [DOI: 10.1111/ejn.13640] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 07/03/2017] [Accepted: 07/04/2017] [Indexed: 12/12/2022]
Affiliation(s)
- Thusharika Dissanayaka
- Department of Physiotherapy; School of Primary Health Care; Faculty of Medicine; Nursing and Health Sciences; Monash University; Melbourne Victoria Australia
| | - Maryam Zoghi
- Department of Rehabilitation, Nutrition and Sport; School of Allied Health; La Trobe University; Bundoora Victoria Australia
| | - Michael Farrell
- Monash Biomedical Imaging; Monash University; Melbourne Victoria Australia
- Biomedicine Discovery Institute and Department of Medical Imaging and Radiation Sciences; Monash University; Melbourne Victoria Australia
| | - Gary F. Egan
- Monash Biomedical Imaging; Monash University; Melbourne Victoria Australia
| | - Shapour Jaberzadeh
- Department of Physiotherapy; School of Primary Health Care; Faculty of Medicine; Nursing and Health Sciences; Monash University; Melbourne Victoria Australia
| |
Collapse
|
37
|
The effect of transcranial direct current stimulation on motor sequence learning and upper limb function after stroke. Clin Neurophysiol 2017; 128:1389-1398. [PMID: 28410884 DOI: 10.1016/j.clinph.2017.03.036] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 03/19/2017] [Accepted: 03/24/2017] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To assess the impact of electrode arrangement on the efficacy of tDCS in stroke survivors and determine whether changes in transcallosal inhibition (TCI) underlie improvements. METHODS 24 stroke survivors (3-124months post-stroke) with upper limb impairment participated. They received blinded tDCS during a motor sequence learning task, requiring the paretic arm to direct a cursor to illuminating targets on a monitor. Four tDCS conditions were studied (crossover); anodal to ipsilesional M1, cathodal to contralesional M1, bihemispheric, sham. The Jebsen Taylor hand function test (JTT) was assessed pre- and post-stimulation and TCI assessed as the ipsilateral silent period (iSP) duration using transcranial magnetic stimulation. RESULTS The time to react to target illumination reduced with learning of the movement sequence, irrespective of tDCS condition (p>0.1). JTT performance improved after unilateral tDCS (anodal or cathodal) compared with sham (p<0.05), but not after bihemispheric (p>0.1). There was no effect of tDCS on change in iSP duration (p>0.1). CONCLUSIONS Unilateral tDCS is effective for improving JTT performance, but not motor sequence learning. SIGNIFICANCE This has implications for the design of future clinical trials.
Collapse
|
38
|
Schroeder PA, Dresler T, Bahnmueller J, Artemenko C, Cohen Kadosh R, Nuerk HC. Cognitive Enhancement of Numerical and Arithmetic Capabilities: a Mini-Review of Available Transcranial Electric Stimulation Studies. JOURNAL OF COGNITIVE ENHANCEMENT 2017. [DOI: 10.1007/s41465-016-0006-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
39
|
Inukai Y, Saito K, Sasaki R, Tsuiki S, Miyaguchi S, Kojima S, Masaki M, Otsuru N, Onishi H. Comparison of Three Non-Invasive Transcranial Electrical Stimulation Methods for Increasing Cortical Excitability. Front Hum Neurosci 2016; 10:668. [PMID: 28082887 PMCID: PMC5186778 DOI: 10.3389/fnhum.2016.00668] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Accepted: 12/15/2016] [Indexed: 01/11/2023] Open
Abstract
Transcranial direct current stimulation (tDCS) is a representative non-invasive brain stimulation method (NIBS). tDCS increases cortical excitability not only in healthy individuals, but also in stroke patients where it contributes to motor function improvement. Recently, two additional types of transcranial electrical stimulation (tES) methods have been introduced that may also prove beneficial for stimulating cortical excitability; these are transcranial random noise stimulation (tRNS) and transcranial alternating current stimulation (tACS). However, comparison of tDCS with tRNS and tACS, in terms of efficacy in cortical excitability alteration, has not been reported thus far. We compared the efficacy of the three different tES methods for increasing cortical excitability using the same subject population and same current intensity. Fifteen healthy subjects participated in this study. Similar stimulation patterns (1.0 mA and 10 min) were used for the three conditions of stimulation (tDCS, tRNS, and tACS). Cortical excitability was explored via single-pulse TMS elicited motor evoked potentials (MEPs). Compared with pre-measurements, MEPs significantly increased with tDCS, tACS, and tRNS (p < 0.05). Compared with sham measurements, significant increases in MEPs were also observed with tRNS and tACS (p < 0.05), but not with tDCS. In addition, a significant correlation of the mean stimulation effect was observed between tRNS and tACS (p = 0.019, r = 0.598). tRNS induced a significant increase in MEP compared with the Pre or Sham at all time points. tRNS resulted in the largest significant increase in MEPs. These findings suggest that tRNS is the most effective tES method and should be considered as part of a treatment plan for improving motor function in stroke patients.
Collapse
Affiliation(s)
- Yasuto Inukai
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Kei Saito
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Ryoki Sasaki
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare Niigata, Japan
| | - Shota Tsuiki
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare Niigata, Japan
| | - Shota Miyaguchi
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Sho Kojima
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Mitsuhiro Masaki
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Naofumi Otsuru
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| | - Hideaki Onishi
- Department of Physical Therapy, Niigata University of Health and WelfareNiigata, Japan; Institute for Human Movement and Medical Sciences, Niigata University of Health and WelfareNiigata, Japan
| |
Collapse
|
40
|
Palm U, Chalah MA, Padberg F, Al-Ani T, Abdellaoui M, Sorel M, Dimitri D, Créange A, Lefaucheur JP, Ayache SS. Effects of transcranial random noise stimulation (tRNS) on affect, pain and attention in multiple sclerosis. Restor Neurol Neurosci 2016; 34:189-99. [PMID: 26890095 DOI: 10.3233/rnn-150557] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE Pain and cognitive impairment are frequent symptoms in patients with multiple sclerosis (MS). Neglecting experimental pain and paying attention to demanding tasks is reported to decrease the pain intensity. Little is known about the interaction between chronic neuropathic pain and attention disorders in MS. Recently, transcranial direct current stimulation (tDCS) was used to modulate various cognitive and motor symptoms in MS. We aimed to study the effects of transcranial random noise stimulation (tRNS), a form of transcranial electric stimulation, over the left dorsolateral prefrontal cortex (DLPFC) on attention and neuropathic pain in MS patients. METHODS 16 MS patients were included in a randomized, sham-controlled, cross-over study. Each patient randomly received two tRNS blocks, separated by three weeks of washout interval. Each block consisted of three consecutive daily sessions of either active or sham tRNS. The patients were evaluated for pain, attention and mood and further underwent an electrophysiological evaluation. RESULTS Compared to sham, tRNS showed a trend to decrease the N2-P2 amplitudes of pain related evoked potentials and improve pain ratings. Attention performance and mood scales did not change after stimulations. CONCLUSIONS This study suggests the role of tRNS in pain modulation, which could have been more evident with longer stimulation protocols.
Collapse
Affiliation(s)
- Ulrich Palm
- Department of Physiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France.,Department of Psychiatry and Psychotherapy, Ludwig-Maximilian University Munich, Munich, Germany
| | - Moussa A Chalah
- Department of Physiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France.,EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France
| | - Frank Padberg
- Department of Psychiatry and Psychotherapy, Ludwig-Maximilian University Munich, Munich, Germany
| | - Tarik Al-Ani
- EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France
| | - Mohamed Abdellaoui
- Department of Neurology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France
| | - Marc Sorel
- EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France
| | - Dalia Dimitri
- Department of Neurology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France
| | - Alain Créange
- EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France.,Department of Neurology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France
| | - Jean-Pascal Lefaucheur
- Department of Physiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France.,EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France
| | - Samar S Ayache
- Department of Physiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris, Créteil, France.,EA 4391, Nerve Excitability and Therapeutic Team, Faculty of Medicine, Paris Est Créteil University, Créteil, France
| |
Collapse
|
41
|
Opposite effects of high- and low-frequency transcranial random noise stimulation probed with visual motion adaptation. Sci Rep 2016; 6:38919. [PMID: 27934947 PMCID: PMC5146960 DOI: 10.1038/srep38919] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Accepted: 11/16/2016] [Indexed: 11/24/2022] Open
Abstract
Transcranial random noise stimulation (tRNS) is a recent neuro-modulation technique whose effects at both behavioural and neural level are still debated. Here we employed the well-known phenomenon of motion after-effect (MAE) in order to investigate the effects of high- vs. low-frequency tRNS on motion adaptation and recovery. Participants were asked to estimate the MAE duration following prolonged adaptation (20 s) to a complex moving pattern, while being stimulated with either sham or tRNS across different blocks. Different groups were administered with either high- or low-frequency tRNS. Stimulation sites were either bilateral human MT complex (hMT+) or frontal areas. The results showed that, whereas no effects on MAE duration were induced by stimulating frontal areas, when applied to the bilateral hMT+, high-frequency tRNS caused a significant decrease in MAE duration whereas low-frequency tRNS caused a significant corresponding increase in MAE duration. These findings indicate that high- and low-frequency tRNS have opposed effects on the adaptation-dependent unbalance between neurons tuned to opposite motion directions, and thus on neuronal excitability.
Collapse
|
42
|
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS). Clin Neurophysiol 2016; 128:56-92. [PMID: 27866120 DOI: 10.1016/j.clinph.2016.10.087] [Citation(s) in RCA: 1034] [Impact Index Per Article: 129.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Revised: 10/18/2016] [Accepted: 10/20/2016] [Indexed: 12/19/2022]
Abstract
A group of European experts was commissioned by the European Chapter of the International Federation of Clinical Neurophysiology to gather knowledge about the state of the art of the therapeutic use of transcranial direct current stimulation (tDCS) from studies published up until September 2016, regarding pain, Parkinson's disease, other movement disorders, motor stroke, poststroke aphasia, multiple sclerosis, epilepsy, consciousness disorders, Alzheimer's disease, tinnitus, depression, schizophrenia, and craving/addiction. The evidence-based analysis included only studies based on repeated tDCS sessions with sham tDCS control procedure; 25 patients or more having received active treatment was required for Class I, while a lower number of 10-24 patients was accepted for Class II studies. Current evidence does not allow making any recommendation of Level A (definite efficacy) for any indication. Level B recommendation (probable efficacy) is proposed for: (i) anodal tDCS of the left primary motor cortex (M1) (with right orbitofrontal cathode) in fibromyalgia; (ii) anodal tDCS of the left dorsolateral prefrontal cortex (DLPFC) (with right orbitofrontal cathode) in major depressive episode without drug resistance; (iii) anodal tDCS of the right DLPFC (with left DLPFC cathode) in addiction/craving. Level C recommendation (possible efficacy) is proposed for anodal tDCS of the left M1 (or contralateral to pain side, with right orbitofrontal cathode) in chronic lower limb neuropathic pain secondary to spinal cord lesion. Conversely, Level B recommendation (probable inefficacy) is conferred on the absence of clinical effects of: (i) anodal tDCS of the left temporal cortex (with right orbitofrontal cathode) in tinnitus; (ii) anodal tDCS of the left DLPFC (with right orbitofrontal cathode) in drug-resistant major depressive episode. It remains to be clarified whether the probable or possible therapeutic effects of tDCS are clinically meaningful and how to optimally perform tDCS in a therapeutic setting. In addition, the easy management and low cost of tDCS devices allow at home use by the patient, but this might raise ethical and legal concerns with regard to potential misuse or overuse. We must be careful to avoid inappropriate applications of this technique by ensuring rigorous training of the professionals and education of the patients.
Collapse
|
43
|
Rehmann R, Sczesny-Kaiser M, Lenz M, Gucia T, Schliesing A, Schwenkreis P, Tegenthoff M, Höffken O. Polarity-Specific Cortical Effects of Transcranial Direct Current Stimulation in Primary Somatosensory Cortex of Healthy Humans. Front Hum Neurosci 2016; 10:208. [PMID: 27242473 PMCID: PMC4860403 DOI: 10.3389/fnhum.2016.00208] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Accepted: 04/22/2016] [Indexed: 11/13/2022] Open
Abstract
Transcranial direct current stimulation (tDCS) is a non-invasive stimulation method that has been shown to modulate the excitability of the motor and visual cortices in human subjects in a polarity dependent manner in previous studies. The aim of our study was to investigate whether anodal and cathodal tDCS can also be used to modulate the excitability of the human primary somatosensory cortex (S1). We measured paired-pulse suppression (PPS) of somatosensory evoked potentials in 36 right-handed volunteers before and after anodal, cathodal, or sham stimulation over the right non-dominant S1. Paired-pulse stimulation of the median nerve was performed at the dominant and non-dominant hand. After anodal tDCS, PPS was reduced in the ipsilateral S1 compared to sham stimulation, indicating an excitatory effect of anodal tDCS. In contrast, PPS in the stimulated left hemisphere was increased after cathodal tDCS, indicating an inhibitory effect of cathodal tDCS. Sham stimulation induced no pre-post differences. Thus, tDCS can be used to modulate the excitability of S1 in polarity-dependent manner, which can be assessed by PPS. An interesting topic for further studies could be the investigation of direct correlations between sensory changes and excitability changes induced by tDCS.
Collapse
Affiliation(s)
- Robert Rehmann
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | | | - Melanie Lenz
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | - Tomasz Gucia
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | - Annika Schliesing
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | - Peter Schwenkreis
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | - Martin Tegenthoff
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| | - Oliver Höffken
- Department of Neurology, BG-Universitaetsklinikum Bergmannsheil Bochum Bochum, Germany
| |
Collapse
|
44
|
Transcranial Alternating Current and Random Noise Stimulation: Possible Mechanisms. Neural Plast 2016; 2016:3616807. [PMID: 27242932 PMCID: PMC4868897 DOI: 10.1155/2016/3616807] [Citation(s) in RCA: 204] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 04/03/2016] [Indexed: 11/17/2022] Open
Abstract
Background. Transcranial alternating current stimulation (tACS) is a relatively recent method suited to noninvasively modulate brain oscillations. Technically the method is similar but not identical to transcranial direct current stimulation (tDCS). While decades of research in animals and humans has revealed the main physiological mechanisms of tDCS, less is known about the physiological mechanisms of tACS. Method. Here, we review recent interdisciplinary research that has furthered our understanding of how tACS affects brain oscillations and by what means transcranial random noise stimulation (tRNS) that is a special form of tACS can modulate cortical functions. Results. Animal experiments have demonstrated in what way neurons react to invasively and transcranially applied alternating currents. Such findings are further supported by neural network simulations and knowledge from physics on entraining physical oscillators in the human brain. As a result, fine-grained models of the human skull and brain allow the prediction of the exact pattern of current flow during tDCS and tACS. Finally, recent studies on human physiology and behavior complete the picture of noninvasive modulation of brain oscillations. Conclusion. In future, the methods may be applicable in therapy of neurological and psychiatric disorders that are due to malfunctioning brain oscillations.
Collapse
|
45
|
Chung SW, Hill AT, Rogasch NC, Hoy KE, Fitzgerald PB. Use of theta-burst stimulation in changing excitability of motor cortex: A systematic review and meta-analysis. Neurosci Biobehav Rev 2016; 63:43-64. [PMID: 26850210 DOI: 10.1016/j.neubiorev.2016.01.008] [Citation(s) in RCA: 165] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Revised: 12/30/2015] [Accepted: 01/26/2016] [Indexed: 12/13/2022]
Abstract
Noninvasive brain stimulation has been demonstrated to modulate cortical activity in humans. In particular, theta burst stimulation (TBS) has gained notable attention due to its ability to induce lasting physiological changes after short stimulation durations. The present study aimed to provide a comprehensive meta-analytic review of the efficacy of two TBS paradigms; intermittent (iTBS) and continuous (cTBS), on corticospinal excitability in healthy individuals. Literature searches yielded a total of 87 studies adhering to the inclusion criteria. iTBS yielded moderately large MEP increases lasting up to 30 min with a pooled SMD of 0.71 (p<0.00001). cTBS produced a reduction in MEP amplitudes lasting up to 60 min, with the largest effect size seen at 5 min post stimulation (SMD=-0.9, P<0.00001). The collected studies were of heterogeneous nature, and a series of tests conducted indicated a degree of publication bias. No significant change in SICI and ICF was observed, with exception to decrease in SICI with cTBS at the early time point (SMD=0.42, P=0.00036). The results also highlight several factors contributing to TBS efficacy, including the number of pulses, frequency of stimulation and BDNF polymorphisms. Further research investigating optimal TBS stimulation parameters, particularly for iTBS, is needed in order for these paradigms to be successfully translated into clinical settings.
Collapse
Affiliation(s)
- Sung Wook Chung
- Monash Alfred Psychiatry Research Centre, Central Clinical School, The Alfred and Monash University, Melbourne, Australia.
| | - Aron T Hill
- Monash Alfred Psychiatry Research Centre, Central Clinical School, The Alfred and Monash University, Melbourne, Australia
| | - Nigel C Rogasch
- Brain and Mental Health Laboratory, School of Psychological Sciences and Monash Biomedical Imaging, Monash University, Melbourne, Australia
| | - Kate E Hoy
- Monash Alfred Psychiatry Research Centre, Central Clinical School, The Alfred and Monash University, Melbourne, Australia
| | - Paul B Fitzgerald
- Monash Alfred Psychiatry Research Centre, Central Clinical School, The Alfred and Monash University, Melbourne, Australia
| |
Collapse
|