1
|
Xiao M, Wang L, Tang Q, Yang Q, Yang X, Zhu G, Lei L, Li S. Postoperative tumor treatment strategies: From basic research to clinical therapy. VIEW 2024; 5. [DOI: 10.1002/viw.20230117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 05/15/2024] [Indexed: 07/04/2024] Open
Abstract
AbstractDespite progression in advanced treatments for malignant tumors, surgery remains the primary treatment intervention, which removes a large portion of firm tumor tissues; however, the postoperative phase poses a possible risk for provincial tumor recurrence and metastasis. Consequently, the prevention of tumor recurrence and metastasis has attracted research attention. In this review, we summarized the postoperative treatment strategies for various tumors from both basic research and clinical perspectives. We delineated the underlying factors contributing to the recurrence of malignant tumors with a substantial prevalence rate, related molecular mechanisms of tumor recurrence post‐surgery, and related means of monitoring recurrence and metastasis after surgery. Furthermore, we described relevant therapeutic approaches for postoperative tumor recurrence, including chemotherapy, radiation therapy, immunotherapy, targeted therapy, and photodynamic therapy. This review focused on the emerging technologies used for postoperative tumor treatment in recent years in terms of functional classification, including the prevention of postoperative tumor recurrence, functional reconstruction, and monitoring of recurrence. Finally, we discussed the future development and deficiencies of postoperative tumor therapy. To understand postoperative treatment strategies for tumors from clinical treatment and basic research and further guide the research directions for postoperative tumors.
Collapse
Affiliation(s)
- Minna Xiao
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| | - Lin Wang
- Department of Otorhinolaryngology Head and Neck Surgery Binzhou People's Hospital Binzhou China
| | - Qinglai Tang
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| | - Qian Yang
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| | - Xinming Yang
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| | - Gangcai Zhu
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| | - Lanjie Lei
- Institute of Translational Medicine Zhejiang Shuren University Hangzhou China
| | - Shisheng Li
- Department of Otorhinolaryngology Head and Neck Surgery The Second Xiangya Hospital Central South University Changsha China
| |
Collapse
|
2
|
Yau LK, Henry FU, Man Hong C, Amy C, Wai Kwan Vincent C, Ping Keung C, Kwong Yuen C. Swelling assessment after total knee arthroplasty. J Orthop Surg (Hong Kong) 2022; 30:10225536221127668. [PMID: 36122907 DOI: 10.1177/10225536221127668] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Total knee arthroplasty is a commonly performed elective orthopaedic surgery. Patients may endure substantial knee swelling following surgery, which are attributable to both effusion and edema. Studies have been aiming to identify an accurate and reliable method to quantify post-operative knee swelling to aid monitoring progress and treatment. The aim of this article was to review the means of clinically applicable measurements for knee swelling post TKA. METHODS The medical literature was searched using PubMed to search for articles published using the terms knee edema, effusion, swelling, knee arthroplasty, knee replacement, total knee arthroplasty, total knee replacement, TKA, TKR. Year of publication was not restricted. Only English language publications were included. Only full-text published articles from peer-reviewed journals were eligible for inclusion. The knee swelling measurement methods used in post TKA were reviewed. RESULTS Advancement in bioimpedance spectroscopy and handheld 3D scanning technology allows quick and precise quantification of knee swelling volume that the traditional clinical circumferential measurement and volumetric measurement lack. Handheld 3D scanning is also a potential tool to estimate the change of knee effusion volume and muscular volume after the surgery. Magnetic resonance imaging is accurate in effusion measurement but also the most time and resource demanding method. CONCLUSION Bioimpedance spectroscopy and 3D scanning technology can be the future tools for clinically measurement of knee swelling after total knee arthroplasty.
Collapse
Affiliation(s)
- Li Ka Yau
- Li Ka Shing Faculty of Medicine, 25809The University of Hong Kong, Hong Kong SAR, China
| | - F U Henry
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 25809The University of Hong Kong, Hong Kong SAR, China
| | - Cheung Man Hong
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 25809The University of Hong Kong, Hong Kong SAR, China
| | - Cheung Amy
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 26473Queen Mary Hospital, Hong Kong SAR, China
| | - Chan Wai Kwan Vincent
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 26473Queen Mary Hospital, Hong Kong SAR, China
| | - Chan Ping Keung
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 25809The University of Hong Kong, Hong Kong SAR, China
| | - Chiu Kwong Yuen
- Division of Joint Replacement Surgery, Department of Orthopaedics and Traumatology, 25809The University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
3
|
Ji T, Yao P, Zeng Y, Qian Z, Wang K, Gao L. Subgaleal Effusion and Brain Midline Shift After Cranioplasty: A Retrospective Study Between Polyetheretherketone Cranioplasty and Titanium Cranioplasty After Decompressive Craniectomy. Front Surg 2022; 9:923987. [PMID: 35937601 PMCID: PMC9351718 DOI: 10.3389/fsurg.2022.923987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 06/10/2022] [Indexed: 11/21/2022] Open
Abstract
Cranioplasty with polyetheretherketone (PEEK) has recently shown better cerebral protection performance, improved brain function, and aesthetic contour compared with titanium mesh. However, whether patients undergoing PEEK cranioplasty tend to develop subgaleal effusions remains elusive. This retrospective study included patients who underwent cranioplasty with PEEK implants or titanium mesh after decompressive craniectomy between July 2017 and July 2020. Patient information, including general information, location, size of the defect, subgaleal depth, and brain midline shift was collected and statistically analyzed. There were 130 cases of cranioplasty, including 35 with PEEK implants and 95 with a titanium mesh. Patients who underwent cranioplasty with a PEEK implant had a higher subgaleal effusion rate than those who underwent cranioplasty with titanium mesh (85.71% vs. 53.68%, P < 0.001), while a midline shift >5 mm was more frequently observed in the PEEK group than in the titanium group (20% vs. 6.3%, P = 0.021). The PEEK material was the only factor associated with subgaleal effusion after cranioplasty (OR 5.589, P = 0.002). Logistic regression analysis further showed that age was a protective factor against midline shift in the PEEK cranioplasty group (OR 0.837, P = 0.029). Patients who underwent cranioplasty with PEEK implants were more likely to develop severe subgaleal effusion and significant brain midline shifts than those with titanium mesh implants.
Collapse
Affiliation(s)
- Tao Ji
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Peiwen Yao
- School of Clinical Medicine, Nanjing Medical University, Nanjing, China
| | - Yu Zeng
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Zhouqi Qian
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Ke Wang
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
- Correspondence: Liang Gao Ke Wang
| | - Liang Gao
- School of Clinical Medicine, Nanjing Medical University, Nanjing, China
- Correspondence: Liang Gao Ke Wang
| |
Collapse
|
4
|
Meng X, Zhang W, Lyu Z, Long T, Wang Y. ZnO nanoparticles attenuate polymer-wear-particle induced inflammatory osteolysis by regulating the MEK-ERK-COX-2 axis. J Orthop Translat 2022; 34:1-10. [PMID: 35531425 PMCID: PMC9046564 DOI: 10.1016/j.jot.2022.04.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/30/2022] [Accepted: 04/03/2022] [Indexed: 11/25/2022] Open
Abstract
Background/Objectives Advanced thermoplastic materials, such as polyether-ether-ketone (PEEK) and highly cross-linked polyethylene (HXLPE), have been increasingly used as orthopaedic implant materials. Similar to other implants, PEEK-on-HXLPE prostheses produce debris from polymer wear that may activate the immune response, which can cause osteolysis, and ultimately implant failure. In this study, we examined whether the anti-inflammatory properties of zinc oxide nanoparticles (ZnO NPs) could attenuate polymer wear particle-induced inflammation. Methods RAW264.7 cells were cultured with PEEK or PE particles and gradient concentrations of ZnO NPs. Intracellular mRNA expression and protein levels of pro-inflammatory factors TNF-α, IL-1β, and IL-6 were detected. An air pouch mouse model was constructed to examine the inflammatory response and expression of pro-inflammatory factors in vivo. Furthermore, an osteolysis rat model was used to evaluate the activation of osteoclasts and destruction of bone tissue induced by polymer particles with or without ZnO NPs. Protein expression of the MEK-ERK-COX-2 pathway was also examined by western blotting to elucidate the mechanism underlying particle-induced anti-inflammatory effects. Results ZnO NPs (≤50 nm, 5 μg/mL) showed no obvious cytotoxicity and attenuated PEEK or PE particle-induced inflammation and inflammatory osteolysis by reducing MEK and ERK phosphorylation and decreasing COX-2 expression. Conclusion ZnO NPs (≤50 nm, 5 μg/mL) attenuated polymer wear particle-induced inflammation via regulation of the MEK-ERK-COX-2 axis. Further, ZnO NPs reduced bone tissue damage caused by particle-induced inflammatory osteolysis. The translational potential of this article Polymer wear particles can induce inflammation and osteolysis in the body after arthroplasty. ZnO NPs attenuated polymer particle-induced inflammation and inflammatory osteolysis. Topical use of ZnO NPs and blended ZnO NP/polymer composites may provide promising approaches for inhibiting polymer wear particle-induced inflammatory osteolysis, thus expanding the range of polymers used in joint prostheses.
Collapse
|
5
|
Cai Z, Qu X, Zhao Y, Yuan Z, Zheng L, Long T, Yao Q, Yue B, Wang Y. Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial. Front Surg 2022; 9:809699. [PMID: 35237649 PMCID: PMC8882580 DOI: 10.3389/fsurg.2022.809699] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 01/24/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) is now frequently performed and is highly successful. However, patient satisfaction after TKA is often difficult to achieve. Because of the presence of metallic prosthetic knee joints, there is a lack of imaging tools that can accurately assess the patient's postoperative prosthetic position, soft tissue impingement, and periprosthetic bone density after TKA. We conducted a clinical trial of the world's first totally modular polyetheretherketone (PEEK) TKA and determined the bone density values in the stress concentration area around the prosthesis based on postoperative computed tomography data to reconstruct a three-dimensional model of the PEEK prosthetic knee joint after implantation. Based on the model, the overhang of the prosthesis was measured at various locations on the prosthesis. METHODS All patients who underwent PEEK-based TKA were postoperatively assessed with radiography and computed tomography (CT). Hounsfield units (HUs) for the different components of the quantitative CT assessment were measured separately. RESULTS Ten patients (nine female and one male) aged 59-74 (mean 66.9, median 67) years were included. The HU values were as follows: PEEK prosthesis mean 182.95, standard deviation (SD) 4.90, coefficient of variation (CV) 2.68; polyethylene mean -89.41, SD 4.14, CV -4.63; lateral femoral osteochondral mean 192.19, SD 55.05, CV 28.64; lateral tibial osteochondral mean 122.94, SD 62.14, CV 42.86; medial femoral osteophyte mean 180.76, SD 43.48, CV 24.05; and medial tibial osteophyte mean 282.59, SD 69.28, CV 24.52. Analysis of the data at 1, 3, and 6 months showed that the mean PE (p = 0.598) and PEEK (p = 0.916) measurements did not change with the time of measurement. There was a decrease in bone mineral density in the lateral tibia at 3 months (p = 0.044). Otherwise, there was no significant change in bone density in other regions (p = 0.124-0.803). There was no overhang in all femoral prostheses, whereas there were two cases of overhang in tibial prostheses. Overhang measurements do not differ significantly across time points. The overhang measurements were not significantly different at all time points (p = 0.186-0.967). CONCLUSION PEEK knee joint prosthesis has excellent CT compatibility. The change in periprosthetic bone volume during the follow-up period can be determined using the HU value after CT scan, while the prosthesis position can be assessed. This assessment may potentially guide future improvements in knee prosthesis alignment techniques and artificial knee prosthesis designs.
Collapse
Affiliation(s)
- Zhengyu Cai
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xinhua Qu
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yaochao Zhao
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Zhiguo Yuan
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Liangjun Zheng
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Teng Long
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qiuying Yao
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Bing Yue
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - You Wang
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
6
|
Imaging Assessment of the Postoperative Spine: An Updated Pictorial Review of Selected Complications. BIOMED RESEARCH INTERNATIONAL 2021; 2021:9940001. [PMID: 34113681 PMCID: PMC8154286 DOI: 10.1155/2021/9940001] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 04/25/2021] [Accepted: 05/05/2021] [Indexed: 02/05/2023]
Abstract
Imaging of the postoperative spine requires the identification of several critical points by the radiologist to be written in the medical report: condition of the underlying cortical and cancellous bone, intervertebral disc, and musculoskeletal tissues; location and integrity of surgical implants; evaluation of the success of decompression procedures; delineation of fusion status; and identification of complications. This article presents a pictorial narrative review of the most common findings observed in noninstrumented and instrumented postoperative spines. Complications in the noninstrumented spine were grouped in early (hematomas, pseudomeningocele, and postoperative spine infection) and late findings (arachnoiditis, radiculitis, recurrent disc herniation, spinal stenosis, and textiloma). Complications in the instrumented spine were also sorted in early (hardware fractures) and late findings (adjacent segment disease, hardware loosening, and implant migration). This review also includes a short description of the most used diagnostic techniques in postoperative spine imaging: plain radiography, ultrasound (US), computed tomography (CT), magnetic resonance (MR), and nuclear medicine. Imaging of the postoperative spine remained a challenging task in the early identification of complications and abnormal healing process. It is crucial to consider the advantages and disadvantages of the imaging modalities to choose those that provide more accurate spinal status information during the follow-up. Our review is directed to all health professionals dealing with the assessment and care of the postoperative spine.
Collapse
|
7
|
Alves CL, Oliveira JS, Tannus A, Tarpani ACSP, Tarpani JR. Detection and Imaging of Damages and Defects in Fibre-Reinforced Composites by Magnetic Resonance Technique. MATERIALS 2021; 14:ma14040977. [PMID: 33669603 PMCID: PMC7921926 DOI: 10.3390/ma14040977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 07/31/2020] [Accepted: 08/03/2020] [Indexed: 11/22/2022]
Abstract
Defectively manufactured and deliberately damaged composite laminates fabricated with different continuous reinforcing fibres (respectively, carbon and glass) and polymer matrices (respectively, thermoset and thermoplastic) were inspected in magnetic resonance imaging equipment. Two pulse sequences were evaluated during non-destructive examination conducted in saline solution-immersed samples to simulate load-bearing orthopaedic implants permanently in contact with biofluids. The orientation, positioning, shape, and especially the size of translaminar and delamination fractures were determined according to stringent structural assessment criteria. The spatial distribution, shape, and contours of water-filled voids were sufficiently delineated to infer the amount of absorbed water if thinner image slices than this study were used. The surface texture of composite specimens featuring roughness, waviness, indentation, crushing, and scratches was outlined, with fortuitous artefacts not impairing the image quality and interpretation. Low electromagnetic shielding glass fibres delivered the highest, while electrically conductive carbon fibres produced the poorest quality images, particularly when blended with thermoplastic polymer, though reliable image interpretation was still attainable.
Collapse
Affiliation(s)
- Carine L. Alves
- Materials Engineering Department, Engineering School of São Carlos, University of São Paulo, São Carlos, SP 13590-566, Brazil; (C.L.A.); (J.S.O.); (A.C.S.P.T.)
| | - Janete S. Oliveira
- Materials Engineering Department, Engineering School of São Carlos, University of São Paulo, São Carlos, SP 13590-566, Brazil; (C.L.A.); (J.S.O.); (A.C.S.P.T.)
| | - Alberto Tannus
- Physics and Informatics Department, Physics Institute of São Carlos, University of São Paulo, São Carlos, SP 13590-566, Brazil;
| | - Alessandra Cristina Soares P. Tarpani
- Materials Engineering Department, Engineering School of São Carlos, University of São Paulo, São Carlos, SP 13590-566, Brazil; (C.L.A.); (J.S.O.); (A.C.S.P.T.)
| | - José R. Tarpani
- Materials Engineering Department, Engineering School of São Carlos, University of São Paulo, São Carlos, SP 13590-566, Brazil; (C.L.A.); (J.S.O.); (A.C.S.P.T.)
- Correspondence:
| |
Collapse
|
8
|
Meng X, Zhang W, Yuan Z, Chen J, Lyu Z, Wang Y. A partial hemi-resurfacing preliminary study of a novel magnetic resonance imaging compatible polyetheretherketone mini-prosthesis for focal osteochondral defects. J Orthop Translat 2021; 26:67-73. [PMID: 33437625 PMCID: PMC7773958 DOI: 10.1016/j.jot.2020.02.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 02/19/2020] [Accepted: 02/22/2020] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The use of partial articular resurfacing surgery with a mini-implant has been gradually increasing; the implant is mainly made of cobalt-chromium metal material, and cartilage changes cannot be monitored after implantation. Thus, we aimed to develop a novel local articular resurfacing polyetheretherketone (PEEK) mini-implant and investigate its feasibility for postoperative magnetic resonance imaging (MRI) monitoring of implant location, bone changes, and cartilage degeneration without artefacts. METHODS Nine skeletally mature female standardised goats were used and divided into the sham, PEEK, and cobalt-chromium-molybdenum alloy (Co-Cr-Mo) groups. The animals underwent local articular resurfacing operation with Co-Cr-Mo alloy (Co-Cr-Mo group) and PEEK (PEEK group) mini-implants. X-ray, computed tomography, and MRI examinations were performed at 12 weeks postoperatively. The sham group underwent a similar surgical procedure to expose the femoral head but without implantation. Gross necropsy and surface topography measurement of the articular cartilage of the acetabulum were performed after sacrificing the animals. Imaging artefacts and opposing cartilage degeneration in the acetabulum were also examined. RESULTS Cartilage damage occurred in both the Co-Cr-Mo and PEEK groups, and the damaged cartilage area was markedly larger in the Co-Cr-Mo group than in the PEEK group, as assessed by gross necropsy and histological staining. The mean surface roughness of the opposing cartilage was approximately 65.3, 117.4, and 188.4 μm at 12 weeks in the sham, PEEK, and Co-Cr-Mo groups, respectively. The Co-Cr-Mo mini-implant was visualised on radiographs, but computed tomography and MR images were markedly affected by artefacts, whereas the opposing cartilage and surrounding tissue were clear on MR images in the PEEK group. Opposing cartilage damage and subchondral bone marrow oedema could be detected by MRI in the PEEK group. CONCLUSIONS The PEEK mini-implant can be a novel alternative to the Co-Cr-Mo mini-implant in articular resurfacing to treat focal osteochondral defects with less cartilage damage. It is feasible to postoperatively monitor the PEEK implant location, surrounding bone changes, and opposing cartilage degeneration by MRI without artefacts. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE The use of MRI to monitor changes in the opposing cartilage after prosthesis implantation has not been widely applied because MR images are generally affected by artefacts generated by the metal prosthesis. This study revealed that the PEEK mini-implant can be a novel alternative to the Co-Cr-Mo mini-implant in articular resurfacing to treat focal osteochondral defects, and it is feasible to monitor the PEEK implant location, surrounding bone changes, and opposing cartilage damage/degeneration by MRI without artefacts postoperatively.
Collapse
Affiliation(s)
- Xiangchao Meng
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Wei Zhang
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Zhiguo Yuan
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Jun Chen
- Department of Head and Neck Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Zhuocheng Lyu
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - You Wang
- Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| |
Collapse
|