1
|
Zhang S, Zhu H, Zhang L, Gao M, Liu C, Zhao Q. Effects of orthokeratology on corneal reshaping and the delaying of axial eye growth in children. Heliyon 2024; 10:e33341. [PMID: 39022009 PMCID: PMC11253518 DOI: 10.1016/j.heliyon.2024.e33341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 06/19/2024] [Accepted: 06/19/2024] [Indexed: 07/20/2024] Open
Abstract
Purpose To investigate the inhibition of myopia progression and axial elongation in children wearing orthokeratology (OK) lenses, as well as to evaluate the status of corneal reshaping, this study explores the relationship between changes in central corneal curvature (K-value) and e-value induced by OK lenses and axial elongation. Methods In this study, it is planned to select children aged 8-15 who wear orthokeratology lenses at the Pediatric Ophthalmology and Strabismus Clinic of the Second Affiliated Hospital of Dalian Medical University. All children will undergo slit lamp examination, visual acuity assessment, computerized refraction, intraocular pressure measurement, biometry, and corneal topography examination before lens wear and at 1 month, 3 months, and 6 months after lens wear in the pediatric ophthalmology clinic. Based on age (lower age group (8 < age ≤12 years); higher age group (12 < age ≤15 years)) and baseline equivalent spherical (SE) value (mild myopia group (-1.00 D < SE ≤ -3.25D); moderate myopia group (-3.25 D < SE ≤ -6.00 D)), four groups will be formed by pairing these factors. Suitable data will be selected according to inclusion and exclusion criteria, and different groups will be included. Data will be organized, and statistical analysis will be performed using SPSS software to obtain the results. The expected results will be discussed and analyzed. Results After wearing OK lenses, all four groups achieved good visual acuity at follow-up. At 6 months, there were no significant differences in visual acuity among the four groups (P = 0.149, >0.05). There were no significant differences in refractive error among the four groups (P = 0.066, >0.05). Baseline axial length differed significantly among the four groups (P = 0.000, <0.001), with the LM group having longer axial length than the LL group (P < 0.001, paired samples t-test), and the HM group having longer axial length than the HL group (P < 0.001, paired samples t-test). However, there were no significant differences in axial length change compared to baseline among the groups at 1 month, 3 months, and 6 months (P 1 = 0.053; P 3 = 0.557; P 6 = 0.329, >0.05). Significant differences were observed in corneal flat K-value change compared to baseline among the four groups at 1 month, 3 months, and 6 months (P 1 = 0.001, P 3 = 0.001, P 6 = 0.004, <0.05). There were no significant differences in e-value change among the groups at 1 and 3 months (P 1 = 0.205, P 3 = 0.252, >0.05), but significant differences were found in e-value change compared to baseline at 6 months (P 6 = 0.010, <0.05). Multiple regression analysis with changes in central corneal flat K-value and e-value as independent variables and axial elongation as the dependent variable showed a correlation between e-value change at 6 months and axial elongation (P = 0.004, <0.05), indicating a negative correlation. Conclusion Orthokeratology (OK) lenses effectively improve myopic children's vision by reshaping the cornea, leading to reduced central corneal curvature and flattening of its anterior surface. The effectiveness of OK lenses is not significantly affected by age or initial myopia severity. Children of varying ages and myopia levels experience similar levels of axial length control with OK lens wear. Changes in corneal shape due to OK lenses affect axial elongation, with greater changes in corneal morphology associated with smaller increases in axial length.
Collapse
Affiliation(s)
- Siqi Zhang
- Second Affiliated Hospital of Dalian Medical University, China
| | - Huailin Zhu
- Second Affiliated Hospital of Dalian Medical University, China
| | - Lan Zhang
- Second Affiliated Hospital of Dalian Medical University, China
| | - Mingjun Gao
- Second Affiliated Hospital of Dalian Medical University, China
| | - Changyang Liu
- Second Affiliated Hospital of Dalian Medical University, China
| | - Qi Zhao
- Second Affiliated Hospital of Dalian Medical University, China
| |
Collapse
|
2
|
Ruan J, Zhang Y, Chen Y. Influence of overnight orthokeratology on tear film and meibomian glands in myopic children: a prospective study. BMC Ophthalmol 2023; 23:136. [PMID: 37013481 PMCID: PMC10071684 DOI: 10.1186/s12886-023-02883-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 03/24/2023] [Indexed: 04/05/2023] Open
Abstract
BACKGROUND Orthokeratology lenses, which are worn overnight, are recommended for reducing myopia progression. They lie on the cornea and can influence the ocular surface by temporarily reshaping the corneal surface through a reverse geometry design. This study investigated the effect of overnight orthokeratology lenses on tear film stability and meibomian gland status in children aged 8-15 years. METHODS This prospective, self-controlled study included 33 children with monocular myopia who were prescribed orthokeratology lenses for at least one year. The experimental group (ortho-k group) comprised 33 myopic eyes. The control group comprised the emmetropic eyes of the same participants. Tear film stability and meibomian gland status were measured using a Keratograph 5M (Oculus, Wetzlar, Germany). Paired t-tests and Wilcoxon signed-rank tests were used to compare the data between the two groups. RESULTS At the one-year visit, the non-invasive first tear film break-up time (NIBUTf) values were 6.15 ± 2.56 s and 6.18 ± 2.61 s in the experimental and control groups, respectively. The lower tear meniscus height was 18.74 ± 0.05 μm and 18.65 ± 0.04 μm in these groups, respectively. No significant difference was observed in loss of meibomian glands or non-invasive average tear film break-up time between the experimental and control groups using Wilcoxon signed-rank tests. CONCLUSIONS The stability of the tear film and meibomian gland status were not significantly affected by wearing orthokeratology lenses overnight, indicating that continuous use of orthokeratology lenses for 12 months has a minimal effect on the ocular surface. This finding can help guide the clinical management of tear film quality with respect to the use of orthokeratology contact lenses.
Collapse
Affiliation(s)
- Jing Ruan
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Huayuan Road, Haidian District, Beijing, 100191, China
| | - Yu Zhang
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Huayuan Road, Haidian District, Beijing, 100191, China.
| | - Yueguo Chen
- Department of Ophthalmology, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Huayuan Road, Haidian District, Beijing, 100191, China.
| |
Collapse
|
3
|
Zhu Q, Yin J, Li X, Hu M, Xue L, Zhang J, Zhou Y, Zhang X, Zhu Y, Zhong H. Effects of Long-Term Wear and Discontinuation of Orthokeratology Lenses on the Eyeball Parameters in Children with Myopia. Int J Med Sci 2023; 20:50-56. [PMID: 36619230 PMCID: PMC9812803 DOI: 10.7150/ijms.79496] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
Objective: To evaluate the effects of long-term wear and discontinuation of the orthokeratology lenses (Orth-K) on the biological parameters of eyeballs in children with myopia. Methods: In this prospective study, a total of 308 subjects with myopia were randomized to receive Orth-K (n = 154) or single vision spectacles (SVS) (n = 154) for 12 months followed by a 1-month withdrawal period. The axial length (AL), the central corneal thickness (CCT), the anterior chamber depth (ACD) and the central lens thickness (CLT) were assessed at the baseline, 6 months, 12 months, and 13 months (1-month after lens withdrawal). Results: A total of 279 subjects completed the 13-month follow-up (142 in Orth-K group and 137 in SVS group). No statistical difference was noted in AL, CCT, ACD and CLT between the two groups at the baseline (all p > 0.05). However, compared with the baseline, the AL from the two groups became elongated 12 months after wearing Orth-K or SVS. The increase of AL in Orth-K group was 0.22 ± 0.11 mm, significantly smaller than 0.35 ± 0.08 mm in SVS group (p < 0.05). In addition, CCT in Orth-K group was 544.26 ± 11.69 µm at 12 months, significantly thinner than 550.49 ± 12.13 µm in SVS group (p < 0.05). Interestingly, the change in CCT between the baseline and 1-month after withdrawal of the lens was not statistically different in either group (all p > 0.05). Furthermore, at 12-months, CLT in Orth-K group was 3.35 ± 0.21 mm, significantly thicker than 3.31 ± 0.15 mm at baseline and thicker than 3.30 ± 0.05 mm in SVS group at 12 months (all p < 0.05). Lastly, ACD was not statistically different between Orth-K and SVS groups at any time point (p > 0.05). Conclusion: Orthokeratology lenses can effectively retard axial elongation, reversibly reduce CCT, increase CLT in myopic children, but have no obvious effect on ACD, indicating that Orth-K may significantly retard myopia without noticeable myopia rebound after interruption of Orth-K.
Collapse
Affiliation(s)
- Qin Zhu
- Department of Ophthalmology, the First Affiliated Hospital of Kunming Medical University, Kunming 650031, China.,Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Jie Yin
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Xuejiao Li
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Min Hu
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Liping Xue
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Jieying Zhang
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Yuan Zhou
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Xiaofan Zhang
- Department of Pediatric Ophthalmology, Affiliated Hospital of Yunnan University; Kunming 650021, China
| | - Yingting Zhu
- BioTissue (Tissue Tech, Inc.), Ocular Surface Center, and Ocular Surface Research & Education Foundation, Miami, FL, 33126 USA
| | - Hua Zhong
- Department of Ophthalmology, the First Affiliated Hospital of Kunming Medical University, Kunming 650031, China
| |
Collapse
|
4
|
Hui W, Xiao-feng H, Song-guo L, Jing-jing W, Xuan H, Yong T. Application of orthokeratology on myopia control and its effect on ocular surface and meibomian gland function in Chinese myopic adolescents. Front Med (Lausanne) 2022; 9:979334. [PMID: 36569150 PMCID: PMC9772008 DOI: 10.3389/fmed.2022.979334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 11/14/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose This study aimed to investigate the influence of orthokeratology (OK) on myopia control and ocular surface and meibomian gland function in myopic adolescents. Methods A prospective study was conducted over a 12-month period. The subjects were classified into two groups, namely, the OK lens group and the frame glasses control group. Axial length, corneal curvature, ocular surface, and meibomian gland parameters were measured at baseline, 1, 3, 6, and 12 months after wearing OK lenses. Results The axial length growth rate in the OK group was significantly slower than in the control group (P < 0.01). The naked eye vision and the ocular surface disease index (OSDI) scores recorded 1, 3, 6, and 12 months after wearing OK lenses were significantly higher than the scores recorded before wearing OK lenses. There was no significant difference in other ocular parameters at each follow-up time point compared with pre-wearing (P > 0.05). After using the OK lens for 6 months, the OSDI score and corneal fluorescein staining (CFS) score increased significantly (P < 0.001), but there were no significant differences in other parameters among the groups. No infectious keratitis occurred during the study. Conclusion These results provide evidence that the use of OK lenses can control the axial growth and progress rate of myopia compared with frame glasses. During the 12-month follow-up, although wearing OK lenses may have aggravated dry eye symptoms, each patient's ocular surface and meibomian gland function did not change significantly, indicating that the use of OK lenses is a relatively safe modality for the control of myopia in adolescents.
Collapse
Affiliation(s)
- Wang Hui
- Department of Ophthalmology, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing, China
| | - Hu Xiao-feng
- Department of Ophthalmology, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing, China
| | - Li Song-guo
- Peking University Shougang Hospital, Beijing, China
| | - Wang Jing-jing
- Beijing Tongzhou Maternity and Child Health Care Hospital, Beijing, China
| | - Huang Xuan
- Department of Ophthalmology, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing, China,*Correspondence: Huang Xuan,
| | - Tao Yong
- Department of Ophthalmology, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing, China
| |
Collapse
|
5
|
Sánchez-González MC, Capote-Puente R, García-Romera MC, De-Hita-Cantalejo C, Bautista-Llamas MJ, Silva-Viguera C, Sánchez-González JM. Dry eye disease and tear film assessment through a novel non-invasive ocular surface analyzer: The OSA protocol. Front Med (Lausanne) 2022; 9:938484. [PMID: 36035382 PMCID: PMC9399399 DOI: 10.3389/fmed.2022.938484] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 07/21/2022] [Indexed: 11/18/2022] Open
Abstract
We describe the role of OSA as a new instrument in the study of dry eye, and we recommend a protocol for conducting the tests as well as describe the advantages and disadvantages compared with other instruments. A comparison with other ocular surface devices (Tearscope Plus, Keratograph 5M, anterior-segment ocular coherence tomography, Easy Tear View-Plus, LipiView, IDRA, and LacryDiag) were presented due to manual or automatic procedure and objective or subjective measurements. The purpose of this study was to describe the OSA as new non-invasive dry eye disease diagnostic device. The OSA is a device that can provide accurate, non-invasive and easy-to-use parameters to specifically interpret distinct functions of the tear film. This OSA protocol proposed a lesser to higher non-invasive ocular surface dry eye disease tear film diagnostic methodology. A complete and exhaustive OSA and OSA Plus examination protocol was presented within the subjective questionnaire (Dry Eye Questionnaire 5, DEQ5), limbal and bulbar redness classification (within the Efron grade Scale, interferometry lipid layer thickness (LLT) (according to Guillon pattern), tear meniscus height (manually or automatic), first and mean non-invasive break up time (objective and automatic) and meibomian gland (MG) dysfunction grade and percentage (objective and automatic). The OSA and OSA Plus devices are novel and relevant dry eye disease diagnostic tools; however, the automatization and objectivity of the measurements can be increased in future software or device updates. The new non-invasive devices supposed represent a renewal in the dry eye disease diagnosis and introduce a tendency to replace the classic invasive techniques that supposed less reliability and reproducibility.
Collapse
|
6
|
Lee J, Hwang G, Ha M, Kim HS, Han K, Na KS. Evaluation of the meibomian glands using the tear interferometer wearing orthokeratology lenses. BMC Ophthalmol 2022; 22:133. [PMID: 35331178 PMCID: PMC8951697 DOI: 10.1186/s12886-022-02365-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 03/14/2022] [Indexed: 11/16/2022] Open
Abstract
Background To investigate the impact of orthokeratology wear on meibomian glands in Korean pediatric population using the tear interferometer. Methods Fifty-three orthokeratology wearers and 79 non-lens wearers were evaluated using the LipiView® II ocular surface interferometer which shows incomplete blink rate, average lipid layer thickness, and meiboscores. Results No significant differences in the incomplete blink rate and meiboscores for upper eyelids, but the lipid layer thickness and meiboscores for lower eyelids were significantly higher in the Ortho-K group than in the control group (p = 0.024 and 0.007, respectively). Correlation analysis showed no significant correlation between the duration of orthokeratology wear and the parameters measured by LipiView® (p > 0.05 for all). Among subgroups based on average duration of lens wear, the longer duration (≥ 24 months) subgroup showed higher meiboscores of lower eyelids (p = 0.011), but no other significant differences. Conclusions Ortho-K wearers showed no significant differences in the incomplete blink rate and meiboscores of upper eyelids, but they were associated with increased LLT and higher meiboscores of lower eyelids. Thorough examination and close monitoring of orthokeratology wearers is necessary. Prospective and observational studies are needed to further elucidate the relationship between Orthokeratology and meibomian glands. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02365-3.
Collapse
Affiliation(s)
- Jiyoung Lee
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Gyudeok Hwang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Minji Ha
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Hyun-Seung Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea
| | - Kyungdo Han
- Department of Statistics and Actuarial Science, Soongsil University, Seoul, 06978, Republic of Korea
| | - Kyung-Sun Na
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
| |
Collapse
|
7
|
Yu H, Yuan Y, Wu W, Zeng W, Tong L, Zhang Y, Feng Y. Orthokeratology Lens Wear for 2 Years in Children Did Not Alter Tear Film Lipid Thickness by Non-Invasive Interferometry. Front Med (Lausanne) 2022; 9:821106. [PMID: 35223920 PMCID: PMC8866645 DOI: 10.3389/fmed.2022.821106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 01/10/2022] [Indexed: 11/20/2022] Open
Abstract
Purpose Previous studies suggest that overnight orthokeratology (OOK) may be detrimental to tear function. We aimed to investigate the effect of OOK on lipid layer thickness (LLT), blink pattern, and meibomian gland and elucidate the relationship of these variables. Methods Thirty-seven participants who wore OOK lenses every night for at least 2 years and twenty-four healthy non-contact lens wearers (controls) were enrolled in this retrospective study. LipiView interferometry, blink pattern analysis, the ocular surface status, and morphology and function of the meibomian gland were determined. Results The OOK group and healthy controls had similar LLT, blink patterns, ocular surface status, and the function of the meibomian gland. OOK participants demonstrated higher meiboscore in the lower eyelids (p < 0.05) but not in the upper eyelids. Within the OOK group, LLT was significantly impacted by the partial blink rate (p < 0.05) and the total score of the upper meibomian gland (p = 0.10). Conclusions Wearing OOK for 2 or more years increased lower eyelid meibomian gland dropout but did not have a reduction of LLT.
Collapse
Affiliation(s)
- Haozhe Yu
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Yifei Yuan
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Wenyu Wu
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Weizhen Zeng
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Louis Tong
- Singapore Eye Research Institute, Singapore, Singapore
- Department of Cornea and External Diseases, Singapore National Eye Centre, Singapore, Singapore
- Department of Ophthalmology, Duke-NUS Medical School, Singapore, Singapore
| | - Yu Zhang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- *Correspondence: Yu Zhang
| | - Yun Feng
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
- Yun Feng
| |
Collapse
|
8
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
9
|
Tao Z, Wang J, Zhu M, Lin Z, Zhao J, Tang Y, Deng H. Does Orthokeratology Wearing Affect the Tear Quality of Children? Front Pediatr 2021; 9:773484. [PMID: 35118029 PMCID: PMC8804288 DOI: 10.3389/fped.2021.773484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 12/14/2021] [Indexed: 11/13/2022] Open
Abstract
Orthokeratology is currently known as one of the most effective methods of myopia control in the process of rapid deterioration of the global myopia prevalence. As orthokeratology is widely used, it is necessary to evaluate its complications reasonably and accurately. Eye surface problems in children, such as dry eyes, have received increasing attention. At present, there is no conclusive evidence on how orthokeratology affects the ocular surface, especially the tears. To our knowledge, this is the first study to explore the relationship between orthokeratology lenses and tears through meta-analysis. However, it is still challenging to get a convincing conclusion and a higher level of evidence in this meta-analysis. Reasons for this include limitation of study design, lack of clarity on important confounding factors, lack of appropriate statistical tools, and other biases. This paper will analyze the dilemma existing in the current research from different perspectives to provide meaningful information for future studies in this field.
Collapse
Affiliation(s)
- Zhengyang Tao
- The Second Clinical Medical College, Jinan University, Shenzhen, China
| | - Jiao Wang
- Department of Strabismus and Pediatric Ophthalmology, Shenzhen Eye Hospital, TheClinical Medical College of Shenzhen University, Shenzhen, China
| | - Minjuan Zhu
- Department of Strabismus and Pediatric Ophthalmology, Shenzhen Eye Hospital Affiliated to Jinan University, The Second Clinical Medical College of Jinan University, Shenzhen, China
| | - Zhihong Lin
- Department of Strabismus and Pediatric Ophthalmology, Shenzhen Eye Hospital Affiliated to Jinan University, The Second Clinical Medical College of Jinan University, Shenzhen, China
| | - Jun Zhao
- Department of Ophthalmology, The Second Clinical Medical College of Jinan University, Longhua Branch Institute of Shenzhen People's Hospital, Shenzhen, China
| | - Yu Tang
- Department of Strabismus and Pediatric Ophthalmology, Shenzhen Eye Hospital Affiliated to Jinan University, The Second Clinical Medical College of Jinan University, Shenzhen, China
| | - Hongwei Deng
- Department of Strabismus and Pediatric Ophthalmology, The Jinan University of Shenzhen Eye Hospital, Shenzhen University of Medicine, Shenzhen, China
| |
Collapse
|
10
|
Cho WH, Fang PC, Yu HJ, Lin PW, Huang HM, Kuo MT. Analysis of tear film spatial instability for pediatric myopia under treatment. Sci Rep 2020; 10:14789. [PMID: 32901095 PMCID: PMC7478966 DOI: 10.1038/s41598-020-71710-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 08/19/2020] [Indexed: 02/08/2023] Open
Abstract
In Taiwan, the prevalence of myopia in children between 6 and 18 years old is over 80%, and high myopia accounts for over 20%, which turned out to be in the leading place worldwide. Orthokeratology and low-dose atropine are proven treatments to reduce myopia progression, though the potential corneal disturbances remain an issue in young populations. The alteration of the tear film is widely discussed but there is no consensus to date, so we aim to investigate the tear film spatial instability in children with myopia control using atropine or orthokeratology. Thirty-eight treatment-naïve participants and 126 myopic children under treatments were enrolled. The ocular surface homeostasis, spatial distribution of tear break-up, and high-order aberrations (HOAs) of the corneal surface were assessed. We found out that myopic children treated with either atropine or orthokeratology showed ocular surface homeostasis similar to that in treatment-naïve children. Nevertheless, children treated with orthokeratology presented higher HOAs (p < 0.00001) and a tendency of the first tear break-up zone at the inner half of the cornea (p = 0.04). This unique spatial instability of the tear film associated with myopia treatment might provide a more focused way of monitoring the pediatric tear film instability.
Collapse
Affiliation(s)
- Wan-Hua Cho
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Po-Chiung Fang
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Hun-Ju Yu
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Pei-Wen Lin
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Hsiu-Mei Huang
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Ming-Tse Kuo
- Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan.
| |
Collapse
|