1
|
A 3D Model of the Jaw Applied to Paediatric Dentistry. Bioengineering (Basel) 2022; 9:bioengineering9040143. [PMID: 35447703 PMCID: PMC9024889 DOI: 10.3390/bioengineering9040143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/02/2022] [Accepted: 03/22/2022] [Indexed: 12/03/2022] Open
Abstract
As education and knowledge are adapted to new education systems, as per the Bologna Plan, new technologies are required for educational support. In dentistry, the creation of virtual simulators can advance understanding in areas like anatomy. With this aim, a three-dimensional virtual model of the maxilo-mandibular system was created, based on a real infantile specimen. Once this model was developed, we applied this virtual structure to a teaching tool in a dentistry subject.The main objective of this project is the creation of a virtual model of the jaw, based on a real and infantile subject that serves as an educative tool in the scope of Paediatric Dentistry Anatomy. The secondary aims were to evaluate this model as an educational tool in a paediatric dentistry subject. For the main objective we obtained tomographic cuts of the craniofacial skeleton of a three-year-old girl that were transcribed to the program Amira 5.3.0. On the cuts, we segmented and named all the mandibular structures: jaw, temporary teeth, and permanent teeth. For the secondary aims we developed virtual clinical cases based on this mandibular model and gave a questionnaire to 29 dentistry students in order to evaluate the tool. A total of 512 cuts were obtained in sagittal and coronal planes and 309 in the cross-sectional plane of a thickness of 0.625 mm. In different colours, we segmented the total 25 structures to generate a three-dimensional mandibular model. For the questionnaire, the results of the students’ satisfaction of the tool were high, with an overall score of 8.5 out of 10. The educative system based on the Bologna Plan is a reality. The self-training based on test and error, is a strategy of extreme utility for the student. With an interactive model, the student is able to value his knowledge instantaneously, and the presence of a professor is not essential at all times. Through this real model, we have described the anatomical study of temporary teething, as well as its interactions with the developing permanent dentition, in a three-dimensional form. The students’ satisfaction of the teaching tool was high.
Collapse
|
2
|
Li L, Chen H, Wang Y, Sun Y. Construction of virtual intercuspal occlusion: Considering tooth displacement. J Oral Rehabil 2021; 48:701-710. [PMID: 33486815 DOI: 10.1111/joor.13153] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/30/2020] [Accepted: 01/14/2021] [Indexed: 11/29/2022]
Abstract
Common impressions cannot accurately duplicate the dental occlusion under occlusal force due to tooth displacement and mandibular deformation. To establish new methods to construct virtual intercuspal occlusion and assess their construction accuracy. The intraoral occlusal contacts of posterior teeth of 15 subjects were recorded with 8 μm and 100 μm articulating paper, respectively, and the marked teeth and buccal bite data were scanned with an intraoral scanner. The virtual dental occlusions were separately determined by buccal bite registration (BBR) method, and 3 new methods, namely segmented tooth registration (STR), occlusal contact areas (marked by 8 μm articulating paper) registration (OCR) and mixing registration (MR) methods. With the intraoral contact areas marked by 100 μm articulating paper set as reference and contact areas of the 4 virtual occlusions as tests, sensitivity, positive predictive value (PPV) and the ratio of overlapping areas were calculated. Kruskal-Wallis test or 1-way ANOVA was used to analyse the difference among groups. The sensitivity ranged from 0.69 to 0.94 and the PPV from 0.67 to 0.90. Sensitivity of OCR group and PPV of STR and OCR groups were different from that of BBR group at overlapping threshold of 50% (P = .028, .028 and .006). There was statistical difference of the ratio of overlapping areas over reference areas, and the values of STR and OCR groups were higher than that of BBR group (P = .045 and .021). The ability of STR and OCR methods to construct virtual intercuspal occlusion was better than BBR method.
Collapse
Affiliation(s)
- Linlin Li
- Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health & Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Diseases, Beijing, China
| | - Hu Chen
- Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health & Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Diseases, Beijing, China
| | - Yong Wang
- Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health & Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Diseases, Beijing, China
| | - Yuchun Sun
- Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health & Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Diseases, Beijing, China
| |
Collapse
|
3
|
Comparison between Occlusal Errors of Single Posterior Crowns Adjusted Using Patient Specific Motion or Conventional Methods. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10249140] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Recently, digital technology has been used in dentistry to enhance accuracy and to reduce operative time. Due to advances in digital technology, the integration of individual mandibular motion into the mapping of the occlusal surface is being attempted. The Patient Specific Motion (PSM) is one such method. However, it is not clear whether the occlusal design that is adjusted using PSM could clinically show reduced occlusal error compared to conventional methods based on static occlusion. In this clinical comparative study including fifteen patients with a single posterior zirconia crown treatment, the occlusal surface after a clinical adjustment was compared to no adjustment (NA; design based on static occlusion), PSM (adjusted using PSM), and adjustment using a semi-adjustable articulator (SA) for the assessment of occlusal error. The root mean square (RMS; μm), average deviation value (±AVG; μm), and proportion inside the tolerance (in Tol; %) were calculated using the entire, subdivided occlusal surface and the out of tolerance area. Using a one-way ANOVA, the RMS and +AVG from the out of tolerance area showed a statistical difference between PSM (202.3 ± 39.8 for RMS, 173.1 ± 31.3 for +AVG) and NA (257.0 ± 73.9 for RMS, 210.9 ± 48.6 for +AVG). For the entire and subdivided occlusal surfaces, there were no significant differences. In the color-coded map analysis, PSM demonstrated a reduced occlusal error compared to NA. In conclusion, adjustment occlusal design using PSM is a simple and effective method for reducing occlusal errors that are difficult to identify in a current computer-aided design (CAD) workflow with static occlusion.
Collapse
|
4
|
Menapace DC, Carlson KD, Dragomir-Daescu D, Matsumoto J, Hamilton GS. Finite Element Analysis of the Septal Cartilage L-Strut. Facial Plast Surg Aesthet Med 2020; 23:90-97. [PMID: 32721238 DOI: 10.1089/fpsam.2019.0012] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Importance: Septoplasty is one of the most commonly performed operations in the head and neck. However, the reasons for septoplasty failure and the additional stress of performing a chondrotomy on the septal cartilage are not well understood. Design, Setting, and Participants: A finite element model of the nasal septum was created using a microcomputed tomography scan of the nasoseptal complex that was reconstructed into a three-dimensional model in silico. Testing included four common chondrotomy designs: traditional L-strut, double-cornered chondrotomy (DCC), curved L-strut, and the C-curve. Tip displacement was applied in a vector parallel to the caudal strut to simulate nasal tip palpation. Main Outcomes and Measures: With finite element analysis, the maximum principal stress (MPS), von Mises stress (VMS), harvested cartilage volume, and surface area were recorded. Results: The highest MPS for the L-strut, DCC, curved L-strut, and C-curve was identified at the corner of the chondrotomy. The MPS at the corner of the chondrotomy was reduced 44% when comparing the C-curve with the traditional L-strut. The VMS patterns showed compressive stress along the caudal septum in all models, but at the corner, the stresses were highest in the chondrotomies designed with sharp-angled corners. The VMS showed a 76% decrease when comparing the C-curve with the traditional L-strut. The stress across the anterior septal angle is also higher in models with sharp-angled corners. Cartilage harvest volumetric and surface area assessments did not show meaningful differences between shapes. Conclusions and Relevance: The highest area of stress is near the transition of the dorsal to caudal septum in all models. Stresses are relatively higher in chondrotomy shapes that contain sharp-angled corners. The relative reduction in MPS and VMS utilizing a C-curve instead of an L-strut may decrease the likelihood that the septum will deform or fail in this region. The volume and surface area of the C-curve are similar to that of the L-strut technique. Avoiding sharp-angled corners reduces the stresses at the corner of the chondrotomy and across the anterior septal angle. Using a C-curve may be an improved septoplasty design.
Collapse
Affiliation(s)
- Deanna C Menapace
- Department of Otolaryngology Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Kent D Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic Rochester, Minnesota, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic Rochester, Minnesota, USA
| | - Jane Matsumoto
- Department of Diagnostic Radiology, Mayo Clinic Rochester, Minnesota, USA
| | - Grant S Hamilton
- Department of Otolaryngology Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
5
|
Saini H, Ackland DC, Gong L, Cheng, Röhrle O. Occlusal load modelling significantly impacts the predicted tooth stress response during biting: a simulation study. Comput Methods Biomech Biomed Engin 2020; 23:261-270. [PMID: 31965827 DOI: 10.1080/10255842.2020.1711886] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Computational models of the masticatory system can provide estimates of occlusal loading during (static) biting or (dynamic) chewing and therefore can be used to evaluate and optimize functional performance of prosthodontic devices and guide dental surgery planning. The modelling assumptions, however, need to be chosen carefully in order to obtain meaningful predictions. The objectives of this study were two-fold: (i) develop a computational model to calculate the stress response of the first molar during biting of a rubber sample and (ii) evaluate the influence of different occlusal load models on the stress response of dental structures. A three-dimensional finite element model was developed comprising the mandible, first molar, associated dental structures, and the articular fossa and discs. Simulations of a maximum force bite on a rubber sample were performed by applying muscle forces as boundary conditions on the mandible and computing the contact between the rubber and molars (GS case). The molar occlusal force was then modelled as a single point force (CF1 case), four point forces (CF2 case), and as a sphere compressing against the occlusal surface (SL case). The peak enamel stress for the GS case was 110 MPa and 677 MPa, 270 MPa and 305 MPa for the CF1, CF2 and SL cases, respectively. Peak dentin stress for the GS case was 44 MPa and 46 MPa, 50 MPa and 63 MPa for the CF1, CF2 and SL cases, respectively. Furthermore, the enamel stress distribution was also strongly correlated to the occlusal load model. The way in which occlusal load is modelled has a substantial influence on the stress response of enamel during biting, but has relatively little impact on the behavior of dentin. The use of point forces or sphere contact to model occlusal loading during mastication overestimates enamel stress magnitude and also influences enamel stress distribution.
Collapse
Affiliation(s)
- Harnoor Saini
- Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - Lulu Gong
- School of Life Sciences and Technology, Tongji University, Shanghai, P.R. China
| | - Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Riddet Institute, Palmerston North, New Zealand
| | - Oliver Röhrle
- Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany.,Stuttgart Center of Simulation Science (SC SimTech), University of Stuttgart, Stuttgart, Germany.,Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA, Stuttgart, Germany
| |
Collapse
|
6
|
Coşkun İ, Kaya B. Relationship between alveolar bone thickness, tooth root morphology, and sagittal skeletal pattern : A cone beam computed tomography study. J Orofac Orthop 2019; 80:144-158. [PMID: 30980091 DOI: 10.1007/s00056-019-00175-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Accepted: 03/11/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE The goal of this work was to examine the relationship between sagittal facial pattern and thickness of alveolar bone in conjunction with root morphology of teeth by using cone beam computed tomography (CBCT). METHODS The study was carried out on the CBCT scans from 3 group of patients (n = 20 in each group). The first group involved skeletal class 1, the second group involved skeletal class 2, and the third group involved skeletal class 3 patients. In all, 14 permanent teeth and interdental regions in the maxilla and mandible were evaluated. Root length and root width were measured on each tooth. Buccal cortical bone thickness, cancellous bone thickness, and lingual cortical bone thicknesses were measured in each interdental region. Analysis of variance, Kruskall-Wallis H and Mann-Whitney U tests were used for statistical comparisons. RESULTS No significant difference was found between the groups for root length, root width, buccal cortical bone and lingual cortical bone thickness. A significant difference was observed between the groups for cancellous bone thickness as it was thicker in skeletal class 2 group. Cortical bone was thicker in the mandible compared to maxilla on both buccal and lingual sides and it was thicker in the posterior region compared to the anterior region on the buccal side. CONCLUSIONS Differences in cancellous bone thickness between different sagittal facial patterns and differences in cortical bone thickness between different alveolar regions should be taken into consideration when planning orthodontic tooth movements and anchorage mechanics.
Collapse
Affiliation(s)
- İpek Coşkun
- Orthodontist, Private Practice, İstanbul, Turkey
| | - Burçak Kaya
- Department of Orthodontics, Faculty of Dentistry, Baskent University, Ankara, Turkey.
- Dis Hekimligi Fakultesi, Ortodonti Anabilim Dali, Baskent Universitesi, 1. Cad No: 107, 06490, Bahcelievler-Ankara, Turkey.
| |
Collapse
|
7
|
Stróżyk P, Bałchanowski J. Modelling of the forces acting on the human stomatognathic system during dynamic symmetric incisal biting of foodstuffs. J Biomech 2018; 79:58-66. [PMID: 30173934 DOI: 10.1016/j.jbiomech.2018.07.046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Revised: 07/31/2018] [Accepted: 07/31/2018] [Indexed: 10/28/2022]
Abstract
A major stage in the preparation of a computational model of the human stomatognathic system is the determination of the values of the forces for the adopted loading configuration. In physiological conditions, food is a factor having a significant effect on the values of the loads acting on the stomatognathic system. Considering that the act of mastication is a complex process, this research undertook to determine the forces (bite forces, muscular forces and temporomandibular joint reaction forces) acting on the stomatognathic system during the dynamic symmetric incisal biting of selected foodstuffs. The investigations were divided into two stages: (1) experimental tests and (2) numerical simulations. In the first stage, classic force-displacement characteristic curves (Fi-Δh) were determined for the food while in the second stage, the curves were used as a dynamic stomatognathic system model load function. One of the most important results of this research is that the food characteristic in the form of a force-displacement function has been shown to have a significant effect not only on the values of the muscular forces and the temporomandibular joint reaction forces, but also on their curves during the dynamic loading of the stomatognathic system. The analysis of the results indicates that Fi-Δh has an effect on not only the (active and passive) forces, but also on other parameters, such as stress, deformation, displacement, and probably the rigidity of the muscles.
Collapse
Affiliation(s)
- Przemysław Stróżyk
- Department of Materials Science, Strength and Welding Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Łukasiewicza 5, 50-371 Wrocław, Poland.
| | - Jacek Bałchanowski
- Department of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Łukasiewicza 5, 50-371 Wrocław, Poland.
| |
Collapse
|
8
|
Resorptive potential of impacted mandibular third molars: 3D simulation by finite element analysis. Clin Oral Investig 2018. [PMID: 29525922 DOI: 10.1007/s00784-018-2403-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVES Previous studies have suggested a relationship between resorption in second molars and pressure from the eruptive force of the third molar. The aim of this study was to simulate functional forces in a mandible model by means of finite element analysis and then assess the biomechanical response produced by impacted third molars on the roots of the second molar. MATERIALS AND METHODS A cone beam computed tomography scan presenting an impacted mandibular third molar was segmented (Mimics V17 software). The modeling process was performed using the reverse engineering technique provided by the Rhinoceros 3D 5.0 software. The third molar position was changed in order to produce different inclinations of the impacted tooth. Bite forces were simulated to evaluate total deformation, the equivalent von Mises stress, minimum principal stress on hard tissue, and equivalent elastic strain on soft tissue. RESULTS Areas of high energy dissipation and compression stress were detected in the second molar root, independently of the inclination of the impacted third molar. In general, the horizontal position was the situation in which major stress and the amount of deformation occurred in the second and third molar regions. CONCLUSION Impacted third molars in close proximity with the adjacent tooth can generate areas of compression concentrated at the site of contact, which suggests an involvement of mechanical factors in the triggering of resorption lesions. CLINICAL RELEVANCE The results of these computational experiments contribute to the understanding of the triggering and progression of resorptive lesions in the adjacent second molar.
Collapse
|
9
|
Boccia E, Gizzi A, Cherubini C, Nestola MGC, Filippi S. Viscoelastic computational modeling of the human head-neck system: Eigenfrequencies and time-dependent analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e2900. [PMID: 28548240 DOI: 10.1002/cnm.2900] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 04/19/2017] [Accepted: 05/21/2017] [Indexed: 06/07/2023]
Abstract
A subject-specific 3-dimensional viscoelastic finite element model of the human head-neck system is presented and investigated based on computed tomography and magnetic resonance biomedical images. Ad hoc imaging processing tools are developed for the reconstruction of the simulation domain geometry and the internal distribution of bone and soft tissues. Material viscoelastic properties are characterized point-wise through an image-based interpolating function used then for assigning the constitutive prescriptions of a heterogenous viscoelastic continuum model. The numerical study is conducted both for modal and time-dependent analyses, compared with similar studies and validated against experimental evidences. Spatiotemporal analyses are performed upon different exponential swept-sine wave-localized stimulations. The modeling approach proposes a generalized, patient-specific investigation of sound wave transmission and attenuation within the human head-neck system comprising skull and brain tissues. Model extensions and applications are finally discussed.
Collapse
Affiliation(s)
- E Boccia
- Max Planck Institute for Dynamics and Self-Organization, Am Faßberg 17, Göttingen, 37077, Germany
| | - A Gizzi
- Department of Engineering, Universitá Campus Bio-Medico di Roma, Via A. del Portillo 21, Rome 00128, Italy
| | - C Cherubini
- Department of Engineering, Universitá Campus Bio-Medico di Roma, Via A. del Portillo 21, Rome 00128, Italy
| | - M G C Nestola
- Universitá della Svizzera italiana, Institute of Computational Science, Via Giuseppe Buffi 13, Lugano 9600, Switzerland
| | - S Filippi
- Department of Engineering, Universitá Campus Bio-Medico di Roma, Via A. del Portillo 21, Rome 00128, Italy
| |
Collapse
|
10
|
Razaghi R, Biglari H, Karimi A. Dynamic finite element simulation of dental prostheses during chewing using muscle equivalent force and trajectory approaches. J Med Eng Technol 2017; 41:314-324. [PMID: 28351224 DOI: 10.1080/03091902.2017.1299231] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The long-term application of dental prostheses inside the bone has a narrow relation to its biomechanical performance. Chewing is the most complicated function of a dental implant as it implements different forces to the implant at various directions. Therefore, a suitable holistic modelling of the jaw bone, implant, food, muscles, and their forces would be deemed significant to figure out the durability as well as functionality of a dental implant while chewing. So far, two approaches have been proposed to employ the muscle forces into the Finite Element (FE) models, i.e. Muscle Equivalent Force (MEF) and trajectory. This study aimed at propounding a new three-dimensional dynamic FE model based on two muscle forces modelling approaches in order to investigate the stresses and deformations in the dental prosthesis as well as maxillary bone during the time of chewing a cornflakes bio. The results revealed that both contact and the maximum von Mises stress in the implant and bones for trajectory approach considerably exceed those of the MEF. The maximum stresses, moreover, are located around the neck of implant which should be both clinically and structurally strong enough to functionally maintain the bone-implant interface. In addition, a higher displacement due to compressive load is observed for the implant head in trajectory approach. The results suggest the benefits provided by trajectory approach since MEF approach would significantly underestimate the stresses and deformations in both the dental prosthesis and bones.
Collapse
Affiliation(s)
- Reza Razaghi
- a Mechanical Engineering Department , University of Tabriz , Tabriz , Iran
| | - Hasan Biglari
- a Mechanical Engineering Department , University of Tabriz , Tabriz , Iran
| | - Alireza Karimi
- b Research Department , Basir Eye Health Research Center , Tehran , Iran
| |
Collapse
|
11
|
Hijazi L, Hejazi W, Darwich MA, Darwich K. Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks. Oral Maxillofac Surg 2016; 20:359-367. [PMID: 27663241 DOI: 10.1007/s10006-016-0573-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 09/05/2016] [Indexed: 11/30/2022]
Abstract
PURPOSE The purpose of the study was to evaluate the effect of clenching tasks on the stress and strain of condylar osteosynthesis screws and plates, as well as on the stress, strain distribution and displacement on the whole mandible and bone surrounding screws. METHODS Three-dimensional finite element models of the mandible, two straight four-hole plates and eight screws were established. Six static clenching tasks were simulated in this study: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), left unilateral molar clench (LMOL), right group function (RGF) and left group function (LGF). RESULTS Based on the simulation of the six clenching tasks, none of the inserted screws and plates were broken or bended. For the whole mandibular bone, the maximum von Mises stress and von Mises strain observed were yielded by the ICP. For the bone surrounding the inserted screws, the maximum von Mises stress and von Mises strain were yielded by the LMOL (49.2 MPa and 3795.1 μ). CONCLUSION Clenching tasks had significant effects on the stress distribution on the condylar osteosynthesis and the bone surrounding screws. Contralateral occlusion task (LMOL) had the maximal results of von Mises stress and strain and healing problems could be occur, this result confirms the importance of soft diet after surgery.
Collapse
Affiliation(s)
- Loai Hijazi
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Damascus University, Damascus, Syria.
| | - Wael Hejazi
- Faculty of Civil Engineering, Damascus University, Damascus, Syria
| | - Mhd Ayham Darwich
- Department of Industrial Automation, Faculty of Technical Engineering, Tartous University, Tartus, Syria
- Faculty of Biomedical Engineering, Al Andalus University for Medical Sciences, Kadmous, Syria
| | - Khaldoun Darwich
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Damascus University, Damascus, Syria
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, International University of Science and Technology, Daraa, Syria
| |
Collapse
|
12
|
Tjoa T, Manuel CT, Leary RP, Harb R, Protsenko DE, Wong BJF. A Finite Element Model to Simulate Formation of the Inverted-V Deformity. JAMA FACIAL PLAST SU 2016; 18:136-43. [PMID: 26720757 PMCID: PMC5828020 DOI: 10.1001/jamafacial.2015.1954] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE Computational modeling can be used to mimic the forces acting on the nasal framework that lead to the inverted-V deformity (IVD) after surgery and potentially determine long-range outcomes. OBJECTIVE To demonstrate the use of the finite element method (FEM) to predict the formation of the IVD after separation of the upper lateral cartilages (ULCs) from the nasal septum. DESIGN, SETTING, AND PARTICIPANTS A computer model of a nose was derived from human computed tomographic data. The septum and upper and lower lateral cartilages were designed to fit within the soft-tissue envelope using computer-aided design software. Mechanical properties were obtained from the literature. The 3 simulations created included (1) partial fusion of the ULCs to the septum, (2) separation of the ULCs from the septum, and (3) a fully connected model to serve as a control. Forces caused by wound healing were prescribed at the junction of the disarticulated ULCs and septum. Using FEM software, equilibrium stress and strain were calculated. Displacement of the soft tissue along the nasal dorsum was measured and evaluated for evidence of morphologic change consistent with the IVD. MAIN OUTCOME AND MEASURES Morphologic changes on the computer models in response to each simulation. RESULTS When a posteroinferior force vector was applied along the nasal dorsum, the areas of highest stress were along the medial edge of the ULCs and at the junction of the ULCs and the nasal bones. With full detachment of ULCs and the dorsal septum, the characteristic IVD was observed. Both separation FEMs produced a peak depression of 0.3 mm along the nasal dorsum. CONCLUSIONS AND RELEVANCE The FEM can be used to simulate the long-term structural complications of a surgical maneuver in rhinoplasty, such as the IVD. When applied to other rhinoplasty maneuvers, the use of FEMs may be useful to simulate the long-term outcomes, particularly when long-term clinical results are not available. In the future, use of FEMs may simulate rhinoplasty results beyond simply morphing the outer contours of the nose and allow estimation of potentially long-term clinical outcomes that may not be readily apparent. LEVEL OF EVIDENCE NA.
Collapse
Affiliation(s)
- Tjoson Tjoa
- Department of Otolaryngology, Massachusetts Eye & Ear Infirmary, Boston
| | - Cyrus T Manuel
- Beckman Laser Institute, University of California, Irvine
| | - Ryan P Leary
- Beckman Laser Institute, University of California, Irvine
| | - Rani Harb
- Beckman Laser Institute, University of California, Irvine
| | | | - Brian J F Wong
- Beckman Laser Institute, University of California, Irvine3Department of Otolaryngology, University of California, Irvine
| |
Collapse
|
13
|
Nagesh S, Shobha ES, Vinay KS, Raghuveer H. Analysis of stress and strain energy fields in craniofacial fracture. 2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON) 2015:1-5. [DOI: 10.1109/bmeicon.2015.7399500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
|
14
|
Biomechanical analysis of a temporomandibular joint condylar prosthesis during various clenching tasks. J Craniomaxillofac Surg 2015; 43:1194-201. [DOI: 10.1016/j.jcms.2015.04.016] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 03/28/2015] [Accepted: 04/22/2015] [Indexed: 11/23/2022] Open
|
15
|
Wu T, Hung A, Mithraratne K. Generating Facial Expressions Using an Anatomically Accurate Biomechanical Model. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2014; 20:1519-1529. [PMID: 26355331 DOI: 10.1109/tvcg.2014.2339835] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper presents a computational framework for modelling the biomechanics of human facial expressions. A detailed high-order (Cubic-Hermite) finite element model of the human head was constructed using anatomical data segmented from magnetic resonance images. The model includes a superficial soft-tissue continuum consisting of skin, the subcutaneous layer and the superficial Musculo-Aponeurotic system. Embedded within this continuum mesh, are 20 pairs of facial muscles which drive facial expressions. These muscles were treated as transversely-isotropic and their anatomical geometries and fibre orientations were accurately depicted. In order to capture the relative composition of muscles and fat, material heterogeneity was also introduced into the model. Complex contact interactions between the lips, eyelids, and between superficial soft tissue continuum and deep rigid skeletal bones were also computed. In addition, this paper investigates the impact of incorporating material heterogeneity and contact interactions, which are often neglected in similar studies. Four facial expressions were simulated using the developed model and the results were compared with surface data obtained from a 3D structured-light scanner. Predicted expressions showed good agreement with the experimental data.
Collapse
|
16
|
Simons WF, De Smit M, Duyck J, Coucke W, Quirynen M. The proportion of cancellous bone as predictive factor for early marginal bone loss around implants in the posterior part of the mandible. Clin Oral Implants Res 2014; 26:1051-9. [DOI: 10.1111/clr.12398] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2014] [Indexed: 12/13/2022]
Affiliation(s)
- Willem-Frederik Simons
- Department of Oral Health Sciences; KU Leuven; University Hospitals Leuven; Leuven Belgium
| | - Menke De Smit
- Department of Oral Health Sciences; KU Leuven; University Hospitals Leuven; Leuven Belgium
| | - Joke Duyck
- Department of Oral Health Sciences; KU Leuven; University Hospitals Leuven; Leuven Belgium
| | - Wim Coucke
- Department of Clinical Biology; Scientific Institute of Public Health; Brussels Belgium
| | - Marc Quirynen
- Department of Oral Health Sciences; KU Leuven; University Hospitals Leuven; Leuven Belgium
| |
Collapse
|
17
|
Manuel CT, Leary R, Protsenko DE, Wong BJF. Nasal tip support: a finite element analysis of the role of the caudal septum during tip depression. Laryngoscope 2013; 124:649-54. [PMID: 23878007 DOI: 10.1002/lary.24321] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Revised: 06/28/2013] [Accepted: 06/28/2013] [Indexed: 11/10/2022]
Abstract
OBJECTIVES/HYPOTHESIS Although minor and major tip support mechanisms have been described in detail, no quantitative models exist to provide support for the relative contributions of the structural properties of the major alar cartilage, the fibrous attachments to surrounding structures, and the rigid support structures in an objective manner. STUDY DESIGN The finite element method was used to compute the stress distribution in the nose during simple tip compression, and then identify the specific anatomic structures that resist deformation and thus contribute to tip support. Additionally, the impact of caudal septal resection on nasal tip support was examined. METHODS The computer models consisted of three tissue components with anatomically correct geometries for skin and bone derived from computed tomographic data. Septum, upper lateral cartilages, and major alar cartilages were fitted within the model using three-dimensional computer-aided design software. Five-millimeter nasal tip compression was performed on the models with caudal septal resection (3 and 5 mm) and without resection to simulate palpation, then the resulting spatial distribution of stress and displacement was calculated. RESULTS The von Mises stress in the normal model was primarily concentrated along the medial crural angle. As caudal septum length was reduced, stress was redistributed to adjacent soft tissue and bone, resulting in less force acting on the septum. In all models, displacement was greatest near the intermediate crura. CONCLUSIONS These models are the first step in the comprehensive mechanical analysis of nasal tip dynamics. Our model supports the concept of the caudal septum and major alar cartilage providing the majority of critical load-bearing support.
Collapse
Affiliation(s)
- Cyrus T Manuel
- Beckman Laser Institute, University of California Irvine, California, U.S.A
| | | | | | | |
Collapse
|
18
|
Frangi AF, Hose DR, Hunter PJ, Ayache N, Brooks D. Special issue on medical imaging and image computing in computational physiology. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013; 32:1-7. [PMID: 23409282 DOI: 10.1109/tmi.2012.2234320] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
|
19
|
The modular endoprosthesis for mandibular body replacement. Part 2: Finite element analysis of endoprosthesis reconstruction of the mandible. J Craniomaxillofac Surg 2012; 40:e487-97. [DOI: 10.1016/j.jcms.2012.03.010] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Revised: 03/12/2012] [Accepted: 03/12/2012] [Indexed: 11/24/2022] Open
|
20
|
Horner KA, Behrents RG, Kim KB, Buschang PH. Cortical bone and ridge thickness of hyperdivergent and hypodivergent adults. Am J Orthod Dentofacial Orthop 2012; 142:170-8. [PMID: 22858325 DOI: 10.1016/j.ajodo.2012.03.021] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2011] [Revised: 03/01/2012] [Accepted: 03/01/2012] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The purpose of this study was to assess differences in dentoalvolar cortical bone thickness between hyperdivergent and hypodivergent young adults. METHODS Pretreatment cone-beam computed tomography images of 57 patients, including 30 hypodivergent subjects (22 women, 8 men) and 27 hyperdivergent subjects (20 women, 7 men), were analyzed. The data were imported into imaging software (version 10.5; Dolphin Imaging Systems, Chatsworth, Calif); standardized orientations were used to measure buccal and lingual cortical bone thicknesses at 16 interradicular sites of the maxilla and the mandible. Total alveolar ridge thickness and medullary space thickness were measured at the same sites. RESULTS T tests showed significant (P <0.05) group differences, with hypodivergent subjects having significantly thicker buccal cortices. The lingual cortex of the maxilla was also significantly thicker in the hypodivergent than in the hyperdivergent subjects. Alveolar ridge thickness was significantly greater at all sites of the hypodivergent mandible and at the anterior 2 sites of the hypodivergent maxilla. Medullary thickness was significantly greater only in the hypodivergent mandibles between the first molars and the second premolars, and between the first and second premolars. Buccal cortical bone was significantly thicker than lingual cortical bone in the mandible; lingual bone was significantly thicker in the maxilla. CONCLUSIONS Cortical bone tends to be thicker in hypodivergent than in hyperdivergent subjects. This explains the concomitant differences in alveolar ridge thickness. Medullary space thickness is largely unaffected by facial divergence.
Collapse
|
21
|
Hannam AG. Current computational modelling trends in craniomandibular biomechanics and their clinical implications. J Oral Rehabil 2010; 38:217-34. [PMID: 20819138 DOI: 10.1111/j.1365-2842.2010.02149.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Computational models of interactions in the craniomandibular apparatus are used with increasing frequency to study biomechanics in normal and abnormal masticatory systems. Methods and assumptions in these models can be difficult to assess by those unfamiliar with current practices in this field; health professionals are often faced with evaluating the appropriateness, validity and significance of models which are perhaps more familiar to the engineering community. This selective review offers a foundation for assessing the strength and implications of a craniomandibular modelling study. It explores different models used in general science and engineering and focuses on current best practices in biomechanics. The problem of validation is considered at some length, because this is not always fully realisable in living subjects. Rigid-body, finite element and combined approaches are discussed, with examples of their application to basic and clinically relevant problems. Some advanced software platforms currently available for modelling craniomandibular systems are mentioned. Recent studies of the face, masticatory muscles, tongue, craniomandibular skeleton, temporomandibular joint, dentition and dental implants are reviewed, and the significance of non-linear and non-isotropic material properties is emphasised. The unique challenges in clinical application are discussed, and the review concludes by posing some questions which one might reasonably expect to find answered in plausible modelling studies of the masticatory apparatus.
Collapse
Affiliation(s)
- A G Hannam
- Faculty of Dentistry, Department of Oral Health Sciences, The University of British Columbia, Vancouver, BC, Canada.
| |
Collapse
|
22
|
Garg AK. Principles of Occlusion in Implant Dentistry. IMPLANT DENT 2010. [DOI: 10.1016/b978-0-323-05566-6.00014-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
23
|
Röhrle O, Waddell JN, Foster KD, Saini H, Pullan AJ. Using a Motion-Capture System to Record Dynamic Articulation for Application in CAD/CAM Software. J Prosthodont 2009; 18:703-10. [DOI: 10.1111/j.1532-849x.2009.00510.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
24
|
Saini H, Wadell JN, Pullan AJ, Röhrle O. Automatically Generating Subject-specific Functional Tooth Surfaces Using Virtual Mastication. Ann Biomed Eng 2009; 37:1646-53. [DOI: 10.1007/s10439-009-9725-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Accepted: 05/22/2009] [Indexed: 10/20/2022]
|
25
|
Detamore MS, Athanasiou KA, Mao J. A call to action for bioengineers and dental professionals: directives for the future of TMJ bioengineering. Ann Biomed Eng 2007; 35:1301-11. [PMID: 17393335 DOI: 10.1007/s10439-007-9298-6] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2006] [Accepted: 03/13/2007] [Indexed: 10/23/2022]
Abstract
The world's first TMJ Bioengineering Conference was held May 25-27, 2006, in Broomfield, Colorado. Presentations were given by 34 invited speakers representing industry, academics, government agencies such as NIH, and private practice, which included surgeons, engineers, biomedical scientists, and patient advocacy leaders. Other attendees included documentary film makers and FDA officials. The impetus for the conference was that the field of TMJ research has been lacking continuity, with no open forum available for surgeons, scientists, and bioengineers to exchange scientific and clinical ideas and identify common goals, strengths, and capabilities. The goal was thus to plant the seeds for establishing a forum for multidisciplinary and interdisciplinary interactions. The collective wisdom and interactions brought about by a melting pot of these diverse individuals has been pooled and is disseminated in this article, which offers specific directives to bioengineers, basic scientists, and medical and dental professionals including oral and maxillofacial surgeons, pain specialists, orthodontists, prosthodontists, endocrinologists, rheumatologists, immunologists, radiologists, neurologists, and orthopaedic surgeons. A primary goal of this article was to attract researchers across a breadth of research areas to lend their expertise to a significant clinical problem with a dire need for new talent. For example, researchers with expertise in finite element modeling will find an extensive list of clinically significant problems. Specific suggestions for TMJ research were presented by the leading organizations for TMJ surgeons and TMJ patients, and further research needs were identified in a series of group discussions. The specific needs identified at the conference and presented here will be essential for those who endeavor to engage in TMJ research, especially in the areas of tissue engineering and biomechanics. Collectively, it is our hope that many of the questions and directives presented here find their way into the proposals of multidisciplinary teams across the world with new and promising approaches to diagnose, prevent and treat TMJ disorders.
Collapse
Affiliation(s)
- Michael S Detamore
- Department of Chemical & Petroleum Engineering, University of Kansas, 1530 W. 15th St., Room 4132, Lawrence, KS 66045-7609, USA.
| | | | | |
Collapse
|
26
|
Röhrle O, Pullan AJ. Three-dimensional finite element modelling of muscle forces during mastication. J Biomech 2007; 40:3363-72. [PMID: 17602693 DOI: 10.1016/j.jbiomech.2007.05.011] [Citation(s) in RCA: 103] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2006] [Revised: 05/04/2007] [Accepted: 05/05/2007] [Indexed: 10/23/2022]
Abstract
This paper presents a three-dimensional finite element model of human mastication. Specifically, an anatomically realistic model of the masseter muscles and associated bones is used to investigate the dynamics of chewing. A motion capture system is used to track the jaw motion of a subject chewing standard foods. The three-dimensional nonlinear deformation of the masseter muscles are calculated via the finite element method, using the jaw motion data as boundary conditions. Motion-driven muscle activation patterns and a transversely isotropic material law, defined in a muscle-fibre coordinate system, are used in the calculations. Time-force relationships are presented and analysed with respect to different tasks during mastication, e.g. opening, closing, and biting, and are also compared to a more traditional one-dimensional model. The results strongly suggest that, due to the complex arrangement of muscle force directions, modelling skeletal muscles as conventional one-dimensional lines of action might introduce a significant source of error.
Collapse
Affiliation(s)
- Oliver Röhrle
- Bioengineering Institute, The University of Auckland, Private Bag 92019, Auckland 1, New Zealand.
| | | |
Collapse
|