1
|
Nayyar S, Downar E, Beheshti M, Liang T, Massé S, Magtibay K, Bhaskaran A, Saeed Y, Vigmond E, Nanthakumar K. Information theory to tachycardia therapy: electrogram entropy predicts diastolic microstructure of reentrant ventricular tachycardia. Am J Physiol Heart Circ Physiol 2019; 316:H134-H144. [DOI: 10.1152/ajpheart.00581.2018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
There is no known strategy to differentiate which multicomponent electrograms in sinus rhythm maintain reentrant ventricular tachycardia (VT). Low entropy in the voltage breakdown of a multicomponent electrogram can localize conditions suitable for reentry but has not been validated against the classic VT activation mapping. We examined whether low entropy in a late and diversely activated ventricular scar region characterizes and differentiates the diastolic path of VT and represents protected tissue channels devoid of side branches. Intraoperative bipolar electrogram (BiEGM) activation and entropy maps were obtained during sinus rhythm in 17 patients with ischemic cardiomyopathy and compared with diastolic activation paths of VT (total of 39 VTs). Mathematical modeling of a zigzag main channel with side branches was also used to further validate structural representation of low entropy in the ventricular scar. A median of one region per patient (range: 1–2 regions) was identified in sinus rhythm, in which BiEGMwith the latest mean activation time and adjacent minimum entropy were assembled together in a high-activation dispersion region. These regions accurately recognized diastolic paths of 34 VTs, often to multiple inducible VTs within a single individual arrhythmogenic region. In mathematical modeling, side branching from the main channel had a strong influence on the BiEGMcomposition along the main channel. The BiEGMobtained from a long unbranched channel had the lowest entropy compared with those with multiple side branches. In conclusion, among a population of multicomponent sinus electrograms, those that demonstrate low entropy and are delayed colocalize to critical long-protected channels of VT. This information is pertinent for planning VT ablation in sinus rhythm.NEW & NOTEWORTHY Entropy is a measure to quantify breakdown in information. Electrograms from a protected tissue channel can only possess a few states in their voltage and thus less information. In contrast, current-load interactions from side branches in unprotected channels introduce a number of dissimilar voltage deflections and thus high information. We compare here a mapping approach based on entropy against a rigorous reference standard of activation mapping during VT and entropy was assessed in sinus rhythm.
Collapse
Affiliation(s)
- Sachin Nayyar
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Eugene Downar
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Mohammadali Beheshti
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Timothy Liang
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Stéphane Massé
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Karl Magtibay
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Abhishek Bhaskaran
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | - Yawer Saeed
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Ontario, Canada
| | | | | |
Collapse
|
2
|
Graham AJ, Orini M, Lambiase PD. Limitations and Challenges in Mapping Ventricular Tachycardia: New Technologies and Future Directions. Arrhythm Electrophysiol Rev 2017; 6:118-124. [PMID: 29018519 DOI: 10.15420/aer.2017.20.1] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Recurrent episodes of ventricular tachycardia in patients with structural heart disease are associated with increased mortality and morbidity, despite the life-saving benefits of implantable cardiac defibrillators. Reducing implantable cardiac defibrillator therapies is important, as recurrent shocks can cause increased myocardial damage and stunning, despite the conversion of ventricular tachycardia/ventricular fibrillation. Catheter ablation has emerged as a potential therapeutic option either for primary or secondary prevention of these arrhythmias, particularly in post-myocardial infarction cases where the substrate is well defined. However, the outcomes of catheter ablation of ventricular tachycardia in structural heart disease remain unsatisfactory in comparison with other electrophysiological procedures. The disappointing efficacy of ventricular tachycardia ablation in structural heart disease is multifactorial. In this review, we discuss the issues surrounding this and examine the limitations of current mapping approaches, as well as newer technologies that might help address them.
Collapse
Affiliation(s)
| | - Michele Orini
- Barts Heart Centre, London.,Institute of Cardiovascular Science, UCL, London, United Kingdom
| | - Pier D Lambiase
- Barts Heart Centre, London.,Institute of Cardiovascular Science, UCL, London, United Kingdom
| |
Collapse
|