1
|
Kim JS, Park SH, Park S, Hwang JH, Kim JH, Pak SY, Lee K, Schmidt B. Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2022; 83:1032-1045. [PMID: 36276211 PMCID: PMC9574290 DOI: 10.3348/jksr.2021.0191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 02/26/2022] [Accepted: 02/28/2022] [Indexed: 12/24/2022]
Abstract
Peripheral arterial disease (PAD) is common in elderly patients. Lower-extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dual-energy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise-reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images.
Collapse
|
2
|
Yoon S, Yoo KH, Park SH, Kim H, Lee JH, Park J, Park SH, Kim HJ. Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study. PLoS One 2022; 17:e0272356. [PMID: 35951525 PMCID: PMC9371255 DOI: 10.1371/journal.pone.0272356] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Accepted: 07/18/2022] [Indexed: 12/04/2022] Open
Abstract
This study aimed to evaluate image quality, the detection rate of enlarged lymph nodes, and radiation dose exposure of ultralow-dose and low-dose abdominopelvic computed tomography (CT) in patients with lymphoma. Patients with lymphoma who underwent abdominopelvic CT using dual-source scanner were retrospectively recruited from a single center. CT images were obtained at 90 kVp dual-source mode reformatted in three data sets using the advanced modelled iterative reconstruction algorithm: 100% (standard-dose CT), 66.7% (low-dose CT), and 33.3% (ultralow-dose CT). Two radiologists analyzed subjective image quality and detection of abdominal enlarged lymph nodes on ultralow-dose, low-dose, and standard-dose CT blindly and independently. The results were compared with reference standards. Three readers (two radiologists and one hematologist) reviewed overall image quality and spleen size. In total, 128 consecutive CT scans (77 complete response, 44 partial response, 6 progressive disease, and 1 initial evaluation) from 86 patients (64 B-cell lymphoma, 14 T/NK-cell lymphoma, and 8 Hodgkin’s lymphoma cases) were assessed. The enlarged lymph node-based detection rates for two readers were 97.0% (96/99) and 94.0% (93/99) on standard-dose CT, 97.0% (96/99) and 94.0% (93/99) on low-dose CT, and 94.0% (93/99) and 89.9% (89/99) on ultralow-dose CT. Overall image quality was 3.8 ± 0.5, 3.9 ± 0.5, and 4.1 ± 0.5 on ultralow-dose CT; 4.7 ± 0.4, 4.6 ± 0.5, and 4.8 ± 0.3 on low-dose CT; and 4.8 ± 0.4, 4.7 ± 0.4, and 4.9 ± 0.2 on standard-dose CT, according to two radiologists and one hematologist, respectively. Intraclass correlation coefficients of spleen size were 0.90 (95% confidence interval [CI], 0.87–0.93), 0.91 (95% CI, 0.88–0.93), and 0.91 (95% CI, 0.88–0.93) on ultralow-dose, low-dose, and standard-dose CT, respectively. Mean effective radiation doses of standard-dose, low-dose, and ultralow-dose CT were 5.7 ±1.8 mSv, 3.8 ± 1.2 mSv, and 1.9 ± 0.6 mSv, respectively. Our findings suggest that ultralow-dose and low-dose CT, even with radiation doses reduced by 66.7% and 33.3%, respectively, maintained adequate image quality. These imaging modalities may be employed for follow-up lymphoma evaluation in consideration of the long surveillance periods.
Collapse
Affiliation(s)
- Sungjin Yoon
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Kwai Han Yoo
- Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
- * E-mail:
| | - Hawk Kim
- Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Jae Hoon Lee
- Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Jinny Park
- Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Seong Ho Park
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
| | - Hwa Jung Kim
- Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, Ulsan University College of Medicine, Seoul, Korea
| |
Collapse
|
3
|
Ren Z, Jiang B, Wu X, Zhang Z, Chen H, Cai H, Fu C. Diagnostic accuracy of dual-energy computed tomography angiography in the differentiation of benign and malignant pelvic masses. Eur J Radiol 2022; 150:110240. [DOI: 10.1016/j.ejrad.2022.110240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 01/27/2022] [Accepted: 03/05/2022] [Indexed: 11/24/2022]
|
4
|
Park S, Park SH, Hwang JH, Kim JH, Lee KH, Park SH, Shin JH, Pak SY, Kang JM. Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose. Clin Radiol 2020; 76:156.e19-156.e26. [PMID: 33256975 DOI: 10.1016/j.crad.2020.10.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 10/28/2020] [Indexed: 01/22/2023]
Abstract
AIM To investigate the image quality and radiation dose of ultralow-dose (ULD) and low-dose (LD) lower-extremity computed tomography (CT) angiography (LE-CTA) using the advanced modelled iterative reconstruction (ADMIRE) algorithm to detect peripheral arterial disease (PAD) in comparison with standard-dose (SD) CT. MATERIALS AND METHODS One hundred and seven consecutive patients were examined using LE-CTA at 70 kVp and a dual-source scanner to achieve three image sets using 30% (ULD), 70% (LD), and 100% (SD) tube loads. Qualitative analysis was conducted by examining the three image sets for overall quality. The image quality of arterial segments was analysed by two independent readers. In addition, the CT dose index (CTDIvol) was measured in the three image sets. RESULTS The mean overall quality scores were 3.4±0.6 for ULD CT, 3.9±0.3 for LD CT, and 3.9±0.2 for SD CT. Both readers scored the arterial segments as 2-4 (adequate-excellent) in the three image sets. In addition, 89.4% (93/104) and 54.8% (57/104) segments of PAD with calcified plaques were scored 4 between SD and LD CT and between SD and ULD CT, respectively, and 45.2% (47/104) segments had a lower score by one point in ULD CT compared with SD CT. The mean CTDIvol was 4.1±1.1 mGy for SD CT, 2.9±0.8 mGy for LD CT, and 1.2±0.3 mGy for ULD CT. CONCLUSIONS LD/ULD CT at 70 kVp using ADMIRE reconstruction enables a reduction in the radiation dose while enabling adequate evaluation or follow-up of PAD based on LE-CTA.
Collapse
Affiliation(s)
- S Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - S H Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - J H Hwang
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea.
| | - J H Kim
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - K H Lee
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - S H Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - J H Shin
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - S Y Pak
- Department of Biomedical Engineering, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - J M Kang
- Department of Surgery, Gil Medical Center, Gachon University College of Medicine, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| |
Collapse
|
5
|
Choi SJ, Ahn SJ, Park SH, Park SH, Pak SY, Choi JW, Shim YS, Jeong YM, Kim B. Dual-source abdominopelvic computed tomography: Comparison of image quality and radiation dose of 80 kVp and 80/150 kVp with tin filter. PLoS One 2020; 15:e0231431. [PMID: 32881876 PMCID: PMC7470424 DOI: 10.1371/journal.pone.0231431] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 08/19/2020] [Indexed: 12/05/2022] Open
Abstract
Objective To compare the radiation dose and the objective and subjective image quality of 80 kVp and 80/150 kVp with tin filter (80/Sn150 kVp) computed tomography (CT) in oncology patients. Methods One-hundred-and-forty-five consecutive oncology patients who underwent third-generation dual-source dual-energy CT of the abdomen for evaluation of malignant visceral, peritoneal, extraperitoneal, and bone tumor were retrospectively recruited. Two radiologists independently reviewed each observation in 80 kVp CT and 80/Sn150 kVp CT. Modified line-density profile of the tumor and contrast-to-noise ratio (CNR) were measured. Diagnostic confidence, lesion conspicuity, and subjective image quality were calculated and compared between image sets. The effective dose and size-specific dose estimate (SSDE) were calculated in the image sets. Results Modified line-density profile analysis revealed higher attenuation differences between the tumor and normal tissue in 80 kVp CT than in 80/Sn150 kVp CT (127 vs. 107, P = 0.05). The 80 kVp CT showed increased CNR in the liver (8.0 vs. 7.6) and the aorta (18.9 vs. 16.3) than the 80/Sn150 kVp CT. The 80 kVp CT yielded higher enhancement of organs (4.9 ± 0.2 vs. 4.7 ± 0.4, P<0.001) and lesion conspicuity (4.9 ± 0.3 vs. 4.8 ± 0.5, P = 0.035) than the 80/Sn150 kVp CT; overall image quality and confidence index were comparable. The effective dose was reduced by 45.2% with 80 kVp CT (2.3 mSv ± 0.9) compared to 80/Sn150 kVp CT (4.1 mSv ± 1.5). The SSDE was 7.4 ± 3.8 mGy on 80/Sn150 kVp CT and 4.1 ± 2.2 mGy on 80 kVp CT. Conclusions The 80 kVp CT reduced the radiation dose by 45.2% in oncology patients while showing comparable or superior image quality to that of 80/Sn150 kVp CT for abdominal tumor evaluation.
Collapse
Affiliation(s)
- Seung Joon Choi
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Su Joa Ahn
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
- * E-mail:
| | - Seong Ho Park
- Division of Abdominal Radiology, Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Seong Yong Pak
- Imaging and Computer Vision Division, Siemens Healthcare, Seoul, Korea
| | - Jae Won Choi
- Imaging and Computer Vision Division, Siemens Healthcare, Seoul, Korea
| | - Young Sup Shim
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Yu Mi Jeong
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Bohyun Kim
- Department of Radiology, Seoul Saint Mary's Hospital, Seoul, Korea
| |
Collapse
|
6
|
Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction. Clin Imaging 2020; 62:41-48. [DOI: 10.1016/j.clinimag.2020.01.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/24/2019] [Accepted: 01/16/2020] [Indexed: 12/15/2022]
|
7
|
Kataria B, Nilsson Althén J, Smedby Ö, Persson A, Sökjer H, Sandborg M. Image quality and pathology assessment in CT Urography: when is the low-dose series sufficient? BMC Med Imaging 2019; 19:64. [PMID: 31399078 PMCID: PMC6688276 DOI: 10.1186/s12880-019-0363-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 07/29/2019] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. METHODS This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. RESULTS For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. CONCLUSION Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.
Collapse
Affiliation(s)
- Bharti Kataria
- Department of Radiology, Linköping University, Linköping, Sweden. .,Department of Medical & Health Sciences, Linköping University, Linköping, Sweden. .,Center for Medical Image Science & Visualization (CMIV), Linköping University, Linköping, Sweden.
| | - Jonas Nilsson Althén
- Department of Medical & Health Sciences, Linköping University, Linköping, Sweden.,Department of Medical Physics, Linköping University, Linköping, Sweden
| | - Örjan Smedby
- Department of Biomedical Engineering and Health Systems (MTH), KTH Royal Institute of Technology, Stockholm, Sweden
| | - Anders Persson
- Department of Radiology, Linköping University, Linköping, Sweden.,Department of Medical & Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science & Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Hannibal Sökjer
- Department of Medical & Health Sciences, Linköping University, Linköping, Sweden
| | - Michael Sandborg
- Department of Medical & Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science & Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Medical Physics, Linköping University, Linköping, Sweden
| |
Collapse
|