Rheologic Behavior of Bovine Calf Serum. MATERIALS (BASEL, SWITZERLAND) 2021; 14:ma14102538. [PMID: 34068363 PMCID: PMC8153264 DOI: 10.3390/ma14102538] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/06/2021] [Accepted: 05/08/2021] [Indexed: 12/23/2022]
Abstract
Recent studies have illuminated the rheological behavior of synovial fluid and the role of protein and hyaluronan (HA). However, with respect to artificial joint replacement in standardized wear simulations, bovine serum is used as fluid test medium. Little is known about the rheological characteristics of bovine serum, which are needed for precise tribological investigations. The steady shear viscosity η of bovine calf serum is determined for protein concentrations used in standardized wear simulations depending on shear rate γ˙ and temperature T. Additionally, the density of the serum is determined for both protein concentrations. The results show shear thinning behavior of bovine calf serum with a nearly Newtonian behavior in the range of high shear rates. Within the range of high shear rates, mean viscosities of η = 0.82-0.88 mPa·s were found for protein concentrations of 20 g/L and mean viscosities of η = 0.88-0.94 mPa·s for 30 g/L, decreasing with temperature. Densities of 1.004-1.005 g/cm3 and 1.007-1.008 g/cm3 were found for 20 and 30 g/L protein concentrations, respectively.
Collapse
|
2
|
Rothammer B, Marian M, Rummel F, Schroeder S, Uhler M, Kretzer JP, Tremmel S, Wartzack S. Rheological behavior of an artificial synovial fluid - influence of temperature, shear rate and pressure. J Mech Behav Biomed Mater 2020; 115:104278. [PMID: 33340776 DOI: 10.1016/j.jmbbm.2020.104278] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 10/30/2020] [Accepted: 12/12/2020] [Indexed: 02/06/2023]
Abstract
Despite the excellent clinical performance of joint replacements, wear-induced aseptic loosening is a main cause of premature implant failure. Tribological testing is usually carried out using bovine serum as an artificial synovial fluid. In order to gain new insights into the suitability to simulate human synovial fluid and provide recommendations for the conditions of tribological testing, accurate rheological measurements on the influence of temperature, shear rate and pressure on density and viscosity were performed. Thus, a temperature dependence of density and viscosity could be verified, whereas both values decreased with higher temperatures. The temperature dependency of viscosity could be approximated by an Arrhenius model. Moreover, shear-thinning characteristics could be demonstrated and fitted to a Cross model, which agreed well with investigations on human synovial fluid reported in literature. Furthermore, an anomaly of pressure dependence of viscosity was found and correlated with the behavior of water as a main constituent. At room temperature, the viscosity initially decreased to a minimum and then increased again as a function of pressure. This was no longer distinct at human body temperatures. Consequently, the present study confirms the suitability of bovine serum as a substitute synovial fluid and emphasizes the importance of realistic testing conditions in order to ensure transferability and comparability.
Collapse
Affiliation(s)
- Benedict Rothammer
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - Max Marian
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | | | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - Maximilian Uhler
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - J Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, Germany.
| | - Stephan Tremmel
- Engineering Design and CAD, University of Bayreuth, Bayreuth, Germany.
| | - Sandro Wartzack
- Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| |
Collapse
|
3
|
Abstract
Total Joint Replacement (TJR) devices undergo standardized wear testing in mechanical simulators while submerged in a proteinaceous testing solution to mimic the environmental conditions of artificial joints in the human body. Typically, bovine calf serum is used to provide the required protein content. However, due to lot-to-lot variability, an undesirable variance in testing outcome is observed. Based on an earlier finding that yellowish-orange serum color saturation is associated with wear rate, we examined potential sources of this variability, by running a comparative wear test with bilirubin; hemin; and a fatty acid, oleic acid, in the lubricant. All these compounds readily bind to albumin, the most abundant protein in bovine serum. Ultrahigh molecular weight polyethylene (UHMWPE) pins were articulated against CoCrMo discs in a pin-on-disc tribometer, and the UHMWPE wear rates were compared between lubricants. We found that the addition of bilirubin increased wear by 121%, while hemin had a much weaker, insignificant effect. When added at the same molar ratio as bilirubin, the fatty acid tended to reduce wear. Additionally, there was a significant interaction with respect to bilirubin and hemin in that UHMWPE wear rate decreased with increasing fatty acid concentration. We believe the conformational change in albumin by binding bilirubin makes it more likely to form molecular bridges between UHMWPE and the metal counterface, thus increasing adhesive wear. However, fatty acids compete for binding sites on albumin, and can prevent this conformational change. Hence, the protein is stabilized, and the chance for albumin to form bridges is lowered. Ultimately, UHMWPE wear rate is driven by the competitive binding of bilirubin and fatty acid to albumin.
Collapse
|
4
|
Effect of type of contact, counterface surface roughness, and contact area on the wear and friction of extensively cross‐linked, vitamin E stabilized UHMWPE. J Biomed Mater Res B Appl Biomater 2019; 108:1985-1992. [DOI: 10.1002/jbm.b.34539] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 11/14/2019] [Accepted: 11/29/2019] [Indexed: 01/01/2023]
|
5
|
Braun S, Sonntag R, Schroeder S, Mueller U, Jaeger S, Gotterbarm T, Kretzer JP. Backside wear in acetabular hip joint replacement. Acta Biomater 2019; 83:467-476. [PMID: 30408561 DOI: 10.1016/j.actbio.2018.10.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 10/30/2018] [Accepted: 10/31/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. Pelvic osteolysis frequently occurs in the region of screw holes, and cup loosening hints to clinically relevant amounts of polyethylene backside wear. It has yet to be confirmed whether backside wear particles differ in size and morphology compared to articulating wear. Previous methods have been limited to subjective assessment of backside surface damages without consideration of wear debris. The aim of this study was to develop and validate a method for quantitative in vitro measurements of polyethylene backside wear in artificial hip cups and to characterize these wear particles for the first time. METHODS Titanium cup-systems (Plasmafit®Plus7, Aesculap, UHMWPE liner) were sinusoidally loaded (2.5 kN) and a torque of 5 Nm was simultaneously applied. The front and rear side of the cup were separated to isolate backside wear. After 2 × 106 cycles the surrounding fluid was filtered and a particle analysis was performed. RESULTS Backside wear had a particles size of 64.1 ± 1.9 nm and was verified as round and oval particles with partly rough outlines. An estimated total number of particles of 1.26 × 109 ± 1.67 × 108 per 106 cycles was determined. CONCLUSION Backside wear was estimated to be several times lower than published values of articulating wear. However, polyethylene backside wear particles represented significantly smaller particles with partly roughened outlines than articulating wear particles and may therefore cause higher biological response in macrophage-mediated bone resorption compared to articulated particles. STATEMENT OF SIGNIFICANCE Within this study, an analytical method for quantitative measuring polyethylene backside wear of artificial hip cups was successfully developed and validated for the first time. It could be shown that backside wear is still present, even in modern cup-systems. These findings can be further used for investigations of the osteolytic potential of polyethylene particles, for evaluating and improving new implant systems and to evaluate the effectiveness of screw hole plugs to prevent the particle migration to the acetabulum.
Collapse
|
6
|
The development of a small-scale wear test for CoCrMo specimens with human synovial fluid. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.biotri.2018.04.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
7
|
Pezzotti G. Raman spectroscopy of biomedical polyethylenes. Acta Biomater 2017; 55:28-99. [PMID: 28359859 DOI: 10.1016/j.actbio.2017.03.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 03/01/2017] [Accepted: 03/09/2017] [Indexed: 12/14/2022]
Abstract
With the development of three-dimensional Raman algorithms for local mapping of oxidation and plastic strain, and the ability to resolve molecular orientation patterns with microscopic spatial resolution, there is an opportunity to re-examine many of the foundations on which our understanding of biomedical grade ultra-high molecular weight polyethylenes (UHMWPEs) are based. By implementing polarized Raman spectroscopy into an automatized tool with an improved precision in non-destructively resolving Euler angles, oxidation levels, and microscopic strain, we become capable to make accurate and traceable measurements of the in vitro and in vivo tribological responses of a variety of commercially available UHMWPE bearings for artificial hip and knee joints. In this paper, we first review the foundations and the main algorithms for Raman analyses of oxidation and strain of biomedical polyethylene. Then, we critically re-examine a large body of Raman data previously collected on different polyethylene joint components after in vitro testing or in vivo service, in order to shed new light on an area of particular importance to joint orthopedics: the microscopic nature of UHMWPE surface degradation in the human body. A complex scenario of physical chemistry appears from the Raman analyses, which highlights the importance of molecular-scale phenomena besides mere microstructural changes. The availability of the Raman microscopic probe for visualizing oxidation patterns unveiled striking findings related to the chemical contribution to wear degradation: chain-breaking and subsequent formation of carboxylic acid sites preferentially occur in correspondence of third-phase regions, and they are triggered by emission of dehydroxylated oxygen from ceramic oxide counterparts. These findings profoundly differ from more popular (and simplistic) notions of mechanistic tribology adopted in analyzing joint simulator data. Statement of Significance This review was dedicated to the theoretical and experimental evaluation of the commercially available biomedical polyethylene samples by Raman spectroscopy with regard to their molecular textures, oxidative patterns, and plastic strain at the microscopic level in the three dimensions of the Euclidean space. The main achievements could be listed, as follow: (i) visualization of molecular patterns at the surface of UHMWPE bearings operating against metallic components; (ii) differentiation between wear and creep deformation in retrievals; (iii) non-destructive mapping of oxidative patterns; and, (iv) the clarification of chemical interactions between oxide/non-oxide ceramic heads and advanced UHMWPE liners.
Collapse
Affiliation(s)
- Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan; Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, 160-0023 Tokyo, Japan; The Center for Advanced Medical Engineering and Informatics, Osaka University, Yamadaoka, Suita, 565-0871 Osaka, Japan; Department of Molecular Cell Physiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, 465 Kajii-cho, Kawaramachi dori, 602-0841 Kyoto, Japan.
| |
Collapse
|
8
|
Medley JB. Can physical joint simulators be used to anticipate clinical wear problems of new joint replacement implants prior to market release? Proc Inst Mech Eng H 2016; 230:347-58. [PMID: 27160555 DOI: 10.1177/0954411916643902] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Accepted: 03/18/2016] [Indexed: 11/16/2022]
Abstract
One of the most important mandates of physical joint simulators is to provide test results that allow the implant manufacturer to anticipate and perhaps avoid clinical wear problems with their new products. This is best done before market release. This study gives four steps to follow in conducting such wear simulator testing. Two major examples involving hip wear simulators are discussed in which attempts had been made to predict clinical wear performance prior to market release. The second one, involving the DePuy ASR implant systems, is chosen for more extensive treatment by making it an illustrative example to explore whether wear simulator testing can anticipate clinical wear problems. It is concluded that hip wear simulator testing did provide data in the academic literature that indicated some risk of clinical wear problems prior to market release of the ASR implant systems. This supports the idea that physical joint simulators have an important role in the pre-market testing of new joint replacement implants.
Collapse
Affiliation(s)
- John B Medley
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
9
|
|
10
|
Reinders J, von Stillfried F, Altan E, Sonntag R, Heitzmann DW, Kretzer JP. Force-controlled dynamic wear testing of total ankle replacements. Acta Biomater 2015; 12:332-340. [PMID: 25448342 DOI: 10.1016/j.actbio.2014.10.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2014] [Revised: 09/19/2014] [Accepted: 10/26/2014] [Indexed: 12/28/2022]
Abstract
Currently, our knowledge of wear performance in total ankle replacements is limited. The aim of this study is to develop a scenario for force-controlled testing and wear testing of total ankle replacements. A force-controlled wear test was developed: based on cadaver measurements, the passive stabilization (ligaments and soft tissue) of the ankle joint was characterized and a restraint model for ankle stabilization was developed. Kinematics and kinetics acting at the replaced ankle joint were defined based on literature data and gait analysis. Afterwards, force-controlled wear testing was carried out on a mobile, three-component, total ankle replacement design. Wear was assessed gravimetrically and wear particles were analyzed. Wear testing resulted in a mean wear rate of 18.2±1.4mm(3)/10(6) cycles. Wear particles showed a mean size of 0.23μm with an aspect ratio of 1.61±0.96 and a roundness of 0.62±0.14. Wear testing of total ankle replacement shows that a relevant wear mass is generated with wear particles in a biologically relevant size range. The developed wear test provides a basis for future wear testing of total ankle replacements.
Collapse
|
11
|
Reinders J, Sonntag R, Kretzer JP. Synovial fluid replication in knee wear testing: an investigation of the fluid volume. J Orthop Res 2015; 33:92-7. [PMID: 25244424 DOI: 10.1002/jor.22736] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 08/22/2014] [Indexed: 02/04/2023]
Abstract
Wear testing cannot replicate the variations in wear rates and wear mechanisms seen in vivo, which may be related to differences between in vivo and in vitro conditions. A considerable difference exists between the in vivo synovial fluid volume (few milliliter) and the in vitro substituted bovine serum volume (several hundred milliliter). The aim of this study was to analyze the effects of a reduced fluid volume on the wear behavior in a knee wear simulator study. Four wear tests with decreasing fluid volumes (250, 150, 75, and 45 ml) were carried out. Using a large fluid volume of 250 ml for wear testing resulted in a wear rate of 9.7±1.2 mm3/10(6) cycles. Decreasing the fluid volume consecutively reduced the wear rate to down to 8.8±1.4 mm3/10(6) for 150 ml (p=1.00), 5.6±1.2 mm3/10(6) for 75 ml (p=0.01), and 1.0±0.2 mm3/10(6) cycles for 45 ml fluid volume (p≤0.01). Additionally, higher serum degradation and larger wear particles were observed with smaller fluid volumes used for testing. This study demonstrates the high relevance of the protein-based lubricant on the wear behavior and the technical limitation to replicate the synovial fluid in simulator tests. Wear testing should be carried out using larger fluid volumes (e.g., 250 ml) to generate physiological relevant wear masses.
Collapse
Affiliation(s)
- Jörn Reinders
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | | | | |
Collapse
|
12
|
CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities. BIOMED RESEARCH INTERNATIONAL 2014; 2014:567374. [PMID: 25506594 PMCID: PMC4258372 DOI: 10.1155/2014/567374] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 09/15/2014] [Accepted: 09/28/2014] [Indexed: 11/18/2022]
Abstract
The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.
Collapse
|
13
|
O'Brien ST, Bohm ER, Petrak MJ, Wyss UP, Brandt JM. An energy dissipation and cross shear time dependent computational wear model for the analysis of polyethylene wear in total knee replacements. J Biomech 2014; 47:1127-33. [PMID: 24480701 DOI: 10.1016/j.jbiomech.2013.12.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2013] [Revised: 12/06/2013] [Accepted: 12/16/2013] [Indexed: 10/25/2022]
|
14
|
Wear testing of crosslinked polyethylene: wear rate variability and microbial contamination. J Mech Behav Biomed Mater 2014; 34:208-16. [PMID: 24607759 DOI: 10.1016/j.jmbbm.2014.02.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Revised: 02/10/2014] [Accepted: 02/11/2014] [Indexed: 11/21/2022]
Abstract
The wear performance of two types of crosslinked polyethylene (Marathon™ and XLK™, DePuy Synthes Inc., Warsaw, IN) was evaluated in a pin-on-disc wear tester, a hip wear simulator, and a knee wear simulator. Sodium azide was used as the microbial inhibitor in the calf serum-based lubricant. In the pin-on-disc wear tester, the Marathon wear rate of 5.33±0.54mm(3)/Mc was significantly lower (p=0.002) than the wear rate of 6.43±0.60mm(3)/Mc for XLK. Inversely, the Marathon wear rate of 15.07±1.03mm(3)/Mc from the hip wear simulator was 2.2-times greater than the XLK wear rate of 6.71±1.03mm(3)/Mc from the knee wear simulator. Differences in implant design, conformity, GUR type, and kinematic test conditions were suggested to account for the difference between the wear rates generated in the different types of wear testing apparati. In all wear tests, sodium azide was ineffective at inhibiting microbial growth in the lubricant. Eight different organisms were identified in the lubricant samples from the wear tests, which suggested the necessity of using an alternative, more effective microbial inhibitor. Careful sample preparation and thorough cleaning has shown to improve the consistency of the wear results. The wear rates generated in the hip and knee wear simulators closely reflected the wear behaviour of Marathon and XLK reported in published data that were tested under similar conditions.
Collapse
|
15
|
Guenther LE, Pyle BW, Turgeon TR, Bohm ER, Wyss UP, Schmidt TA, Brandt JM. Biochemical analyses of human osteoarthritic and periprosthetic synovial fluid. Proc Inst Mech Eng H 2014; 228:127-39. [DOI: 10.1177/0954411913517880] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Biochemical analyses were performed on osteoarthritic and periprosthetic synovial fluid in order to propose changes to lubricant specifications currently outlined in orthopaedic wear testing standards. Osteoarthritic and periprosthetic synovial fluid samples were obtained from the hip and knee joints of 40 patients. The samples in each group were analysed and compared in order to identify differences between the protein concentration, constituent fractions, osmolality, thermal stability and the hyaluronic acid concentration and molecular weight distribution of osteoarthritic and periprosthetic synovial fluid. The average total protein concentration was approximately 30 g/L, which was much higher than the 20 g/L currently specified in the knee wear testing standard; however, the 30 g/L protein concentration matched the recently revised standard for hip simulator wear testing. No significant difference was found between the protein concentration, osmolality, thermal stability, and hyaluronic acid concentration of osteoarthritic and periprosthetic synovial fluid. The clinical data provided should be used to better define the composition of a more clinically relevant lubricant for orthopaedic wear testing.
Collapse
Affiliation(s)
- Leah E Guenther
- Department of Mechanical and Manufacturing Engineering, University of Manitoba, Winnipeg, MB, Canada
- Concordia Joint Replacement Group, Winnipeg, MB, Canada
| | - Bryan W Pyle
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | | | - Eric R Bohm
- Concordia Joint Replacement Group, Winnipeg, MB, Canada
| | - Urs P Wyss
- Department of Mechanical and Manufacturing Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Tannin A Schmidt
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Jan-M Brandt
- Department of Mechanical and Manufacturing Engineering, University of Manitoba, Winnipeg, MB, Canada
- Concordia Joint Replacement Group, Winnipeg, MB, Canada
| |
Collapse
|
16
|
Schröder C, Reinders J, Zietz C, Utzschneider S, Bader R, Kretzer JP. Characterization of polyethylene wear particle: The impact of methodology. Acta Biomater 2013; 9:9485-91. [PMID: 23933100 DOI: 10.1016/j.actbio.2013.07.039] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 07/25/2013] [Accepted: 07/31/2013] [Indexed: 10/26/2022]
Abstract
Due to the prevalence of problems caused by wear particles, the reduced durability of total joint replacements is well documented. The characterization of wear debris enables the size and morphology of these wear particles to be measured and provides an assessment of the biological response in vivo. However, the impact of different methodologies of particle analysis is not yet clear. Hence, the aim of this investigation was to analyze the influence of different particle characterization methods performed by three research centers within the scope of a "round robin test". To obtain knowledge about possible pitfalls, single steps of the particle characterization process (storage, pore size of the filter, coating durations by gold sputtering and scanning electron microscopy (SEM) magnification) were analyzed. The round robin test showed significant differences between the research groups, especially for the morphology of the particles. The SEM magnification was identified as having the greatest influence on the size and shape of the particles, followed by the storage conditions of the wear particle containing lubricant. Gold sputter coating and filter pore size also exhibit significant effects. However, even though they are statistically significant, it should be emphasized that the differences are small. In conclusion, particle characterization is a complex analytical method with a multiplicity of influencing factors. It becomes apparent that a comparison of wear particle results between different research groups is challenging.
Collapse
|
17
|
Moghadas P, Mahomed A, Hukins DWL, Shepherd DET. Effect of lubricants on friction in laboratory tests of a total disc replacement device. Proc Inst Mech Eng H 2013; 227:988-93. [PMID: 23804950 DOI: 10.1177/0954411913485059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Some designs of total disc replacement devices have articulating bearing surfaces, and these devices are tested in vitro with a lubricant of diluted calf serum. It is believed that the lubricant found in total disc replacement devices in vivo is interstitial fluid that may have properties between that in Ringer's solution and diluted calf serum. To investigate the effect of lubricants, a set of friction tests were performed on a generic model of a metal against metal ball-and-socket total disc replacement device. Two devices were tested: one with a ball radius of 10 mm and other with a ball radius of 16 mm; each device had a radial clearance of 0.015 mm. A spine simulator was used to measure frictional torque for each device in axial rotation, flexion-extension and lateral bending at frequencies of 0.25-2 Hz, under 1200 N axial load. Each device was tested with two different lubricants: a solution of new born calf serum diluted with deionised water and Ringer's solution. The results showed that the frictional torque generated between the bearing surfaces was significantly higher in Ringer's solution than in diluted calf serum. The use of Ringer's solution as a lubricant provides a stringent test condition to detect possible problems. Diluted calf serum is more likely to provide an environment closer to that in vivo. However, the precise properties of the fluid lubricating a total disc replacement device are not known; hence, tests using diluted calf serum may not necessarily give the same results as those obtained in vivo.
Collapse
Affiliation(s)
- Parshia Moghadas
- School of Mechanical Engineering, University of Birmingham, Birmingham, UK
| | | | | | | |
Collapse
|
18
|
Scholes SC, Joyce TJ. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials. Proc Inst Mech Eng H 2013; 227:693-703. [PMID: 23636752 DOI: 10.1177/0954411913481549] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bovine serum is the lubricant recommended by several international standards for the wear testing of orthopaedic biomaterials; however, there are issues over its use due to batch variation, degradation, cost and safety. For these reasons, alternative lubricants were investigated. A 50-station Super-CTPOD (circularly translating pin-on-disc) wear test rig was used, which applied multidirectional motion to ultra-high-molecular-weight polyethylene test pins rubbing against cobalt chromium discs. Thirteen possible alternative lubricants were tested. The use of soy protein as a lubricant gave statistically higher wear, while soya oil, olive oil, Channel Island milk, whole milk, whey, wheatgerm oil, 11 mg/mL egg white, albumin/globulin mix and albumin/globulin/chondroitin sulphate mix all gave statistically lower wear than bovine serum. The lubricants giving the closest wear results to bovine serum were 20 and 40 mg/mL egg white solutions. A light absorbance assay found that these egg white solutions suffered from a high degradation rate that increased with increasing protein content. While egg white solutions offer the best alternative lubricant to bovine serum due to the wear volumes produced, cost-effectiveness and safety of handling, protein degradation will still occur, leading to the need for regular lubricant replacement. Of the lubricants tested in this study, none were found to be superior to bovine serum.
Collapse