Tovbis D, Lee E, Koh RGL, Jeong R, Agur A, Yoo PB. Enhancing the selective electrical activation of human vagal nerve fibers: a comparative computational modeling study with validation in a rat sciatic model. J Neural Eng 2023; 20:066012. [PMID: 37963401 DOI: 10.1088/1741-2552/ad0c60] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 11/14/2023] [Indexed: 11/16/2023]
Abstract
Objective.Vagus nerve stimulation (VNS) is an emerging treatment option for a myriad of medical disorders, where the method of delivering electrical pulses can vary depending on the clinical indication. In this study, we investigated the relative effectiveness of electrically activating the cervical vagus nerve among three different approaches: nerve cuff electrode stimulation (NCES), transcutaneous electrical nerve stimulation (TENS), and enhanced TENS (eTENS). The objectives were to characterize factors that influenced nerve activation and to compare the nerve recruitment properties as a function of nerve fiber diameter.Methods.The Finite Element Model, based on data from the Visible Human Project, was implemented in COMSOL. The three simulation types were compared under a range of vertical and horizontal displacements relative to the location of the vagus nerve. Monopolar anodic stimulation was examined, along with latency and activation of different fiber sizes. Nerve activation was determined via the activating function and McIntyre-Richardson-Grill models, and activation thresholds were validated in anin-vivorodent model.Results.While NCES produced the lowest activation thresholds, eTENS generally performed superior to TENS under the range of conditions and fiber diameters, producing activation thresholds up to three times lower than TENS. eTENS also preserved its enhancement when surface electrodes were displaced away from the nerve. Anodic stimulation revealed an inhibitory region that removed eTENS benefits. eTENS also outperformed TENS by up to four times when targeting smaller diameter nerve fibers, scaling similar to a cuff electrode. In latency and activation of smaller diameter nerve fibers, eTENS results resembled those of NCES more than a TENS electrode. Activation threshold ratios were consistent inin-vivovalidation.Significance.Our findings expand upon previously identified mechanisms for eTENS and further demonstrate how eTENS emulates a nerve cuff electrode to achieve lower activation thresholds. This work further characterizes considerations required for VNS under the three stimulation methods.
Collapse
Affiliation(s)
- Daniel Tovbis
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Eugene Lee
- Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
| | - Ryan G L Koh
- KITE Research Institute, Toronto Rehabilitation Institute, University Health Network, Toronto, Canada
| | - Rania Jeong
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
| | - Anne Agur
- Division of Anatomy, Department of Surgery, University of Toronto, Toronto, Canada
- Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada
| | - Paul B Yoo
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
- Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada
| |
Collapse
|
2
|
Readioff R, Siddiqui ZK, Stewart C, Fulbrook L, O’Connor RJ, Chadwick EK. Use and evaluation of assistive technologies for upper limb function in tetraplegia. J Spinal Cord Med 2022; 45:809-820. [PMID: 33606599 PMCID: PMC9662059 DOI: 10.1080/10790268.2021.1878342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
CONTEXT More than half of all spinal cord injuries (SCI) occur at the cervical level leading to loss of upper limb function, restricted activity and reduced independence. Several technologies have been developed to assist with upper limb functions in the SCI population. OBJECTIVE There is no clear clinical consensus on the effectiveness of the current assistive technologies for the cervical SCI population, hence this study reviews the literature in the years between 1999 and 2019. METHODS A systematic review was performed on the state-of-the-art assistive technology that supports and improves the function of impaired upper limbs in cervical SCI populations. Combinations of terms, covering assistive technology, SCI, and upper limb, were used in the search, which resulted in a total of 1770 articles. Data extractions were performed on the selected studies which involved summarizing details on the assistive technologies, characteristics of study participants, outcome measures, and improved upper limb functions when using the device. RESULTS A total of 24 articles were found and grouped into five categories, including neuroprostheses (invasive and non-invasive), orthotic devices, hybrid systems, robots, and arm supports. Only a few selected studies comprehensively reported characteristics of the participants. There was a wide range of outcome measures and all studies reported improvements in upper limb function with the devices. CONCLUSIONS This study highlighted that assistive technologies can improve functions of the upper limbs in SCI patients. It was challenging to draw generalizable conclusions because of factors, such as heterogeneity of recruited participants, a wide range of outcome measures, and the different technologies employed.
Collapse
Affiliation(s)
- Rosti Readioff
- School of Pharmacy and Bioengineering, Keele University, Stoke-on-Trent, UK,Correspondence to: Rosti Readioff, Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LeedsLS2 9JT, UK. ; @Dr_Rosti
| | - Zaha Kamran Siddiqui
- Academic Department of Rehabilitation Medicine, Faculty of Medicine and Health, University of Leeds, Leeds, UK
| | - Caroline Stewart
- School of Pharmacy and Bioengineering, Keele University, Stoke-on-Trent, UK,The Orthotic Research and Locomotor Assessment Unit (ORLAU), the Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Foundation Trust, Oswestry, UK
| | - Louisa Fulbrook
- The Orthotic Research and Locomotor Assessment Unit (ORLAU), the Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Foundation Trust, Oswestry, UK
| | - Rory J. O’Connor
- Academic Department of Rehabilitation Medicine, Faculty of Medicine and Health, University of Leeds, Leeds, UK
| | | |
Collapse
|
3
|
Cardoso LRL, Bochkezanian V, Forner-Cordero A, Melendez-Calderon A, Bo APL. Soft robotics and functional electrical stimulation advances for restoring hand function in people with SCI: a narrative review, clinical guidelines and future directions. J Neuroeng Rehabil 2022; 19:66. [PMID: 35773733 PMCID: PMC9245887 DOI: 10.1186/s12984-022-01043-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 06/02/2022] [Indexed: 11/10/2022] Open
Abstract
Background Recovery of hand function is crucial for the independence of people with spinal cord injury (SCI). Wearable devices based on soft robotics (SR) or functional electrical stimulation (FES) have been employed to assist the recovery of hand function both during activities of daily living (ADLs) and during therapy. However, the implementation of these wearable devices has not been compiled in a review focusing on the functional outcomes they can activate/elicit/stimulate/potentiate. This narrative review aims at providing a guide both for engineers to help in the development of new technologies and for clinicians to serve as clinical guidelines based on the available technology in order to assist and/or recover hand function in people with SCI. Methods A literature search was performed in Scopus, Pubmed and IEEE Xplore for articles involving SR devices or FES systems designed for hand therapy or assistance, published since 2010. Only studies that reported functional outcomes from individuals with SCI were selected. The final collections of both groups (SR and FES) were analysed based on the technical aspects and reported functional outcomes. Results A total of 37 out of 1101 articles were selected, 12 regarding SR and 25 involving FES devices. Most studies were limited to research prototypes, designed either for assistance or therapy. From an engineering perspective, technological improvements for home-based use such as portability, donning/doffing and the time spent with calibration were identified. From the clinician point of view, the most suitable technical features (e.g., user intent detection) and assessment tools should be determined according to the particular patient condition. A wide range of functional assessment tests were adopted, moreover, most studies used non-standardized tests. Conclusion SR and FES wearable devices are promising technologies to support hand function recovery in subjects with SCI. Technical improvements in aspects such as the user intent detection, portability or calibration as well as consistent assessment of functional outcomes were the main identified limitations. These limitations seem to be be preventing the translation into clinical practice of these technological devices created in the laboratory.
Collapse
Affiliation(s)
- Lucas R L Cardoso
- Biomedical Engineering, School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia.
| | - Vanesa Bochkezanian
- College of Health Sciences, School of Health, Medical and Applied Sciences, Central Queensland University, North Rockhampton, Australia
| | - Arturo Forner-Cordero
- Biomechatronics Laboratory, Escola Politecnica, University of São Paulo, São Paulo, Brazil
| | - Alejandro Melendez-Calderon
- Biomedical Engineering, School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia.,School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia.,Jamieson Trauma Institute, Royal Brisbane and Women's Hospital, Metro North Hospital and Health Service, Brisbane, Australia
| | - Antonio P L Bo
- Biomedical Engineering, School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| |
Collapse
|
4
|
Roointan S, Tovbis D, Elder C, Yoo PB. Enhanced transcutaneous electrical nerve stimulation achieved by a localized virtual bipole: a computational study of human tibial nerve stimulation. J Neural Eng 2020; 17:026041. [PMID: 32241001 DOI: 10.1088/1741-2552/ab85d3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Electrical neuromodulation is a clinically effective therapeutic instrument, currently expanding into newer indications and larger patient populations. Neuromodulation technologies are also moving towards less invasive approaches to nerve stimulation. In this study, we investigated an enhanced transcutaneous electrical nerve stimulation (eTENS) system that electrically couples a conductive nerve cuff with a conventional TENS electrode. The objectives were to better understand how eTENS achieves lower nerve activation thresholds, and to test the feasibility of applying eTENS in a human model of peripheral nerve stimulation. APPROACH A finite element model (FEM) of the human lower leg was constructed to simulate electrical stimulation of the tibial nerve, comparing TENS and eTENS. Key variables included surface electrode diameter, nerve cuff properties (conductivity, length, thickness), and cuff location. Enhanced neural excitability was predicted by relative excitability (RE > 1), derived using either the activating function (AF) or the nerve activation threshold (MRG model). MAIN RESULTS Simulations revealed that a localized 'virtual bipole' was created on the target nerve, where the isopotential surface of the cuff resulted in large potential differences with the surrounding tissue. The cathodic part (nerve depolarization) of the bipole enhanced neural excitability, predicted by RE values of up to 2.2 (MRG) and 5.5 (AF) when compared to TENS. The MRG model confirmed that action potentials were initiated at the cathodic edge of the nerve cuff. Factors contributing to eTENS were larger surface electrodes, longer cuffs, cuff conductivity (>1×103 S m-1), and cuff position relative to the cathodic surface electrode. SIGNIFICANCE This study provides a theoretical basis for designing and testing eTENS applied to various neural targets and data suggesting function of eTENS in large models of nerve stimulation. Although eTENS carries key advantages over existing technologies, further work is needed to translate this approach into effective clinical applications.
Collapse
Affiliation(s)
- Sohrab Roointan
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College Street, Room 407, Toronto, Ontario M5S 3G9, Canada
| | | | | | | |
Collapse
|
5
|
|
6
|
A Wearable Body Controlling Device for Application of Functional Electrical Stimulation. SENSORS 2018; 18:s18041251. [PMID: 29670039 PMCID: PMC5948602 DOI: 10.3390/s18041251] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Revised: 04/14/2018] [Accepted: 04/17/2018] [Indexed: 11/28/2022]
Abstract
In this research, we describe a new balancing device used to stabilize the rear quarters of a patient dog with spinal cord injuries. Our approach uses inertial measurement sensing and direct leg actuation to lay a foundation for eventual muscle control by means of direct functional electrical stimulation (FES). During this phase of development, we designed and built a mechanical test-bed to develop the control and stimulation algorithms before we use the device on our animal subjects. We designed the bionic test-bed to mimic the typical walking gait of a dog and use it to develop and test the functionality of the balancing device for stabilization of patient dogs with hindquarter paralysis. We present analysis for various muscle stimulation and balancing strategies, and our device can be used by veterinarians to tailor the stimulation strength and temporal distribution for any individual patient dog. We develop stabilizing muscle stimulation strategies using the robotic test-bed to enhance walking stability. We present experimental results using the bionic test-bed to demonstrate that the balancing device can provide an effective sensing strategy and deliver the required motion control commands for stabilizing an actual dog with a spinal cord injury.
Collapse
|
7
|
Barss TS, Ainsley EN, Claveria-Gonzalez FC, Luu MJ, Miller DJ, Wiest MJ, Collins DF. Utilizing Physiological Principles of Motor Unit Recruitment to Reduce Fatigability of Electrically-Evoked Contractions: A Narrative Review. Arch Phys Med Rehabil 2017; 99:779-791. [PMID: 28935232 DOI: 10.1016/j.apmr.2017.08.478] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 08/08/2017] [Accepted: 08/16/2017] [Indexed: 10/18/2022]
Abstract
Neuromuscular electrical stimulation (NMES) is used to produce contractions to restore movement and reduce secondary complications for individuals experiencing motor impairment. NMES is conventionally delivered through a single pair of electrodes over a muscle belly or nerve trunk using short pulse durations and frequencies between 20 and 40Hz (conventional NMES). Unfortunately, the benefits and widespread use of conventional NMES are limited by contraction fatigability, which is in large part because of the nonphysiological way that contractions are generated. This review provides a summary of approaches designed to reduce fatigability during NMES, by using physiological principles that help minimize fatigability of voluntary contractions. First, relevant principles of the recruitment and discharge of motor units (MUs) inherent to voluntary contractions and conventional NMES are introduced, and the main mechanisms of fatigability for each contraction type are briefly discussed. A variety of NMES approaches are then described that were designed to reduce fatigability by generating contractions that more closely mimic voluntary contractions. These approaches include altering stimulation parameters, to recruit MUs in their physiological order, and stimulating through multiple electrodes, to reduce MU discharge rates. Although each approach has unique advantages and disadvantages, approaches that minimize MU discharge rates hold the most promise for imminent translation into rehabilitation practice. The way that NMES is currently delivered limits its utility as a rehabilitative tool. Reducing fatigability by delivering NMES in ways that better mimic voluntary contractions holds promise for optimizing the benefits and widespread use of NMES-based programs.
Collapse
Affiliation(s)
- Trevor S Barss
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada
| | - Emily N Ainsley
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Francisca C Claveria-Gonzalez
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, AB, Canada
| | - M John Luu
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Dylan J Miller
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada
| | - Matheus J Wiest
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Biomechanics Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, Brazil
| | - David F Collins
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
8
|
Kato K, Sasada S, Nishimura Y. Flexible adaptation to an artificial recurrent connection from muscle to peripheral nerve in man. J Neurophysiol 2016; 115:978-91. [PMID: 26631144 DOI: 10.1152/jn.00143.2015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Accepted: 12/01/2015] [Indexed: 11/22/2022] Open
Abstract
Controlling a neuroprosthesis requires learning a novel input-output transformation; however, how subjects incorporate this into limb control remains obscure. To elucidate the underling mechanisms, we investigated the motor adaptation process to a novel artificial recurrent connection (ARC) from a muscle to a peripheral nerve in healthy humans. In this paradigm, the ulnar nerve was electrically stimulated in proportion to the activation of the flexor carpi ulnaris (FCU), which is ulnar-innervated and monosynaptically innervated from Ia afferents of the FCU, defined as the "homonymous muscle," or the palmaris longus (PL), which is not innervated by the ulnar nerve and produces similar movement to the FCU, defined as the "synergist muscle." The ARC boosted the activity of the homonymous muscle and wrist joint movement during a visually guided reaching task. Participants could control muscle activity to utilize the ARC for the volitional control of wrist joint movement and then readapt to the absence of the ARC to either input muscle. Participants reduced homonymous muscle recruitment with practice, regardless of the input muscle. However, the adaptation process in the synergist muscle was dependent on the input muscle. The activity of the synergist muscle decreased when the input was the homonymous muscle, whereas it increased when it was the synergist muscle. This reorganization of the neuromotor map, which was maintained as an aftereffect of the ARC, was observed only when the input was the synergist muscle. These findings demonstrate that the ARC induced reorganization of neuromotor map in a targeted and sustainable manner.
Collapse
Affiliation(s)
- Kenji Kato
- Department of Developmental Physiology, National Institute for Physiological Sciences, Okazaki, Japan; Department of Physiological Sciences, School of Life Science, The Graduate University for Advanced studies (SOKENDAI), Hayama, Japan; The Japan Society for the Promotion of Science, Tokyo, Japan; and
| | - Syusaku Sasada
- Department of Developmental Physiology, National Institute for Physiological Sciences, Okazaki, Japan
| | - Yukio Nishimura
- Department of Developmental Physiology, National Institute for Physiological Sciences, Okazaki, Japan; Department of Physiological Sciences, School of Life Science, The Graduate University for Advanced studies (SOKENDAI), Hayama, Japan; Precursory Research for Embryonic Science and Technology, Japan Science and Technology Agency, Tokyo, Japan
| |
Collapse
|
9
|
|
10
|
Prochazka A. Sensory control of normal movement and of movement aided by neural prostheses. J Anat 2015; 227:167-77. [PMID: 26047134 PMCID: PMC4523319 DOI: 10.1111/joa.12311] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/11/2015] [Indexed: 11/27/2022] Open
Abstract
Signals from sensory receptors in muscles and skin enter the central nervous system (CNS), where they contribute to kinaesthesia and the generation of motor commands. Many lines of evidence indicate that sensory input from skin receptors, muscle spindles and Golgi tendon organs play the predominant role in this regard. Yet in spite of over 100 years of research on this topic, some quite fundamental questions remain unresolved. How does the CNS choose to use the ability to control muscle spindle sensitivity during voluntary movements? Do spinal reflexes contribute usefully to load compensation, given that the feedback gain must be quite low to avoid instability? To what extent do signals from skin stretch receptors contribute? This article provides a brief review of various theories, past and present, that address these questions. To what extent has the knowledge gained resulted in clinical applications? Muscles paralyzed as a result of spinal cord injury or stroke can be activated by electrical stimulation delivered by neuroprostheses. In practice, at most two or three sensors can be deployed on the human body, providing only a small fraction of the information supplied by the tens of thousands of sensory receptors in animals. Most of the neuroprostheses developed so far do not provide continuous feedback control. Instead, they switch from one state to another when signals from their one or two sensors meet pre-set thresholds (finite state control). The inherent springiness of electrically activated muscle provides a crucial form of feedback control that helps smooth the resulting movements. In spite of the dissimilarities, parallels can be found between feedback control in neuroprostheses and in animals and this can provide surprising insights in both directions.
Collapse
Affiliation(s)
- Arthur Prochazka
- Neuroscience and Mental Health Institute, University of AlbertaEdmonton, AB, Canada
| |
Collapse
|
11
|
Grahn PJ, Mallory GW, Berry BM, Hachmann JT, Lobel DA, Lujan JL. Restoration of motor function following spinal cord injury via optimal control of intraspinal microstimulation: toward a next generation closed-loop neural prosthesis. Front Neurosci 2014; 8:296. [PMID: 25278830 PMCID: PMC4166363 DOI: 10.3389/fnins.2014.00296] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2014] [Accepted: 08/31/2014] [Indexed: 11/13/2022] Open
Abstract
Movement is planned and coordinated by the brain and carried out by contracting muscles acting on specific joints. Motor commands initiated in the brain travel through descending pathways in the spinal cord to effector motor neurons before reaching target muscles. Damage to these pathways by spinal cord injury (SCI) can result in paralysis below the injury level. However, the planning and coordination centers of the brain, as well as peripheral nerves and the muscles that they act upon, remain functional. Neuroprosthetic devices can restore motor function following SCI by direct electrical stimulation of the neuromuscular system. Unfortunately, conventional neuroprosthetic techniques are limited by a myriad of factors that include, but are not limited to, a lack of characterization of non-linear input/output system dynamics, mechanical coupling, limited number of degrees of freedom, high power consumption, large device size, and rapid onset of muscle fatigue. Wireless multi-channel closed-loop neuroprostheses that integrate command signals from the brain with sensor-based feedback from the environment and the system's state offer the possibility of increasing device performance, ultimately improving quality of life for people with SCI. In this manuscript, we review neuroprosthetic technology for improving functional restoration following SCI and describe brain-machine interfaces suitable for control of neuroprosthetic systems with multiple degrees of freedom. Additionally, we discuss novel stimulation paradigms that can improve synergy with higher planning centers and improve fatigue-resistant activation of paralyzed muscles. In the near future, integration of these technologies will provide SCI survivors with versatile closed-loop neuroprosthetic systems for restoring function to paralyzed muscles.
Collapse
Affiliation(s)
- Peter J. Grahn
- Mayo Clinic College of Medicine, Mayo ClinicRochester, MN, USA
| | | | | | - Jan T. Hachmann
- Department of Neurologic Surgery, Mayo ClinicRochester, MN, USA
| | | | - J. Luis Lujan
- Department of Neurologic Surgery, Mayo ClinicRochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo ClinicRochester, MN, USA
| |
Collapse
|
12
|
Biering-Sørensen F, Bryden A, Curt A, Friden J, Harvey LA, Mulcahey MJ, Popovic MR, Prochazka A, Sinnott KA, Snoek G. International Spinal Cord Injury Upper Extremity Basic Data Set. Spinal Cord 2014; 52:652-7. [DOI: 10.1038/sc.2014.87] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 04/28/2014] [Accepted: 05/03/2014] [Indexed: 11/09/2022]
|
13
|
Current Trends in the Management of the Upper Limb in Spinal Cord Injury. CURRENT PHYSICAL MEDICINE AND REHABILITATION REPORTS 2013. [DOI: 10.1007/s40141-013-0020-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Chipman PH, Toma JS, Rafuse VF. Generation of motor neurons from pluripotent stem cells. PROGRESS IN BRAIN RESEARCH 2012. [DOI: 10.1016/b978-0-444-59544-7.00015-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|