1
|
Xie Y, Zhu Y, Shi Y, Zhao Y, Zhang H, Li F, Song H, Chen L, Guo W. Impact of Cross-Limb Stent-Graft Configuration on Hemodynamics in Abdominal Aortic Aneurysm Interventional Therapy. Cardiovasc Eng Technol 2024; 15:137-146. [PMID: 37985614 DOI: 10.1007/s13239-023-00702-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Accepted: 11/07/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE The cross-limb (CL) technique is a commonly used endovascular treatment for addressing unfavorable anatomical features in patients with abdominal aortic aneurysm (AAA). The configuration of CL stent-graft plays a critical role in determining the postoperative hemodynamic properties and physiological behaviors, which ultimately impact the efficacy and safety of endovascular AAA treatment. This study aims to investigate the relationship between hemodynamics and CL stent-graft configuration from a hemodynamic perspective. METHODS Five distinct geometric models of cross-limb (CL) stent-graft configurations were constructed by optimizing the real clinical computed tomography angiography (CTA) data. These models varied in main body lengths and cross angles and were used to perform numerical simulations to analyze various hemodynamic parameters. Flow pattern, distribution of wall shear stress (WSS)-related parameters, localized normalized helicity (LNH), pressure drop, and the displacement force of all models were examined in this paper. RESULTS In patient-specific cases, helical flow and WSS increase with the main body. However, it also generated secondary flow in localized areas, leading to increased oscillation in the WSS direction. Notably, increasing the stent graft's main body length or decreasing the cross angle reduced the displacement force exerted on the stent-graft. Reducing the cross angle did not significantly alter the hemodynamic characteristics. CONCLUSION In the clinical practice of CL deployment, it is crucial to carefully consider the stent-graft configuration and the patient specific to achieve optimal postoperative outcomes. This study provides valuable insights for guiding stent selection and treatment planning in patients with abdominal aortic aneurysm undergoing CL techniques, from a hemodynamic perspective.
Collapse
Affiliation(s)
- Yanqing Xie
- Department of Cardiology, The First Affiliated Hospital of Ningbo University, Ningbo, 315020, China
| | - Yating Zhu
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China
| | - Yike Shi
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Yawei Zhao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China
| | - Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, 79 West Yingze Street, Taiyuan, 030024, China.
| | - Hui Song
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, 79 West Yingze Street, Taiyuan, 030024, China
| | - Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Wei Guo
- Department of Vascular Surgery, First Medical Center of Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853, China.
| |
Collapse
|
2
|
Li F, Zhu Y, Song H, Zhang H, Chen L, Guo W. Analysis of Postoperative Remodeling Characteristics after Modular Inner Branched Stent-Graft Treatment of Aortic Arch Pathologies Using Computational Fluid Dynamics. Bioengineering (Basel) 2023; 10:bioengineering10020164. [PMID: 36829658 PMCID: PMC9952632 DOI: 10.3390/bioengineering10020164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 01/14/2023] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
The modular inner branched stent-graft (MIBSG), a novel interventional therapy, has demonstrated good effects in the endovascular treatment of aortic arch pathologies, especially those involving the supra-aortic branches. Nevertheless, the long-term efficacy of the MIBSG and in-depth quantitative evaluation of postoperative outcomes remain to be examined. Moreover, the regularity of postoperative vascular remodeling induced by MIBSG implantation has yet to be explored. To address these questions, we constructed four models (normal, preoperative, 1 week postoperative, and 6 months postoperative) based on a single patient case to perform computational fluid dynamics simulations. The morphological and hemodynamic characteristics, including the velocity profile, flow rate distribution, and hemodynamic parameter distribution (wall shear stress and its derivative parameters), were investigated. After MIBSG implantation, the morphology of the supra-aortic branches changed significantly, and the branch point moved forward to the proximal ascending aorta. Moreover, the curvature radius of the aortic arch axis continued to change. These changes in morphology altered the characteristics of the flow field and wall shear stress distribution. As a result, the local forces exerted on the vessel wall by the blood led to vessel remodeling. This study provides insight into the vascular remodeling process after MIBSG implantation, which occurs as a result of the interplay between vascular morphological characteristics and blood flow characteristics.
Collapse
Affiliation(s)
- Fen Li
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Institute of Applied Mechanics, Taiyuan University of Technology, Taiyuan 030024, China
| | - Yating Zhu
- First Medical Center of Chinese PLA General Hospital, Department of Vascular Surgery, Beijing 100853, China
| | - Hui Song
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Institute of Applied Mechanics, Taiyuan University of Technology, Taiyuan 030024, China
| | - Hongpeng Zhang
- First Medical Center of Chinese PLA General Hospital, Department of Vascular Surgery, Beijing 100853, China
| | - Lingfeng Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Correspondence: (L.C.); (W.G.)
| | - Wei Guo
- First Medical Center of Chinese PLA General Hospital, Department of Vascular Surgery, Beijing 100853, China
- Correspondence: (L.C.); (W.G.)
| |
Collapse
|
3
|
Fast and Accurate Computation of the Displacement Force of Stent Grafts after Endovascular Aneurysm Repair. Bioengineering (Basel) 2022; 9:bioengineering9090447. [PMID: 36134992 PMCID: PMC9495395 DOI: 10.3390/bioengineering9090447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 11/24/2022] Open
Abstract
Purpose: Currently, the displacement force of stent grafts is generally obtained using computational fluid dynamics (CFD), which requires professional CFD knowledge to perform the correct simulation. This study proposes a fast, simple, and clinician-friendly approach to calculating the patient-specific displacement force after endovascular aneurysm repair (EVAR). Methods: Twenty patient-specific post-EVAR computed tomography angiography images were used to reconstruct the patient-specific three-dimensional models, then the displacement forces were calculated using CFD and the proposed approaches, respectively, and their numerical differences were compared and analyzed. Results: Based on the derivation and simplification of the momentum theorem, the patient-specific displacement forces were obtained using the information of the patient-specific pressure, cross-sectional area, and angulation of the two stent graft ends, and the average relative error was no greater than 1.37% when compared to the displacement forces calculated by CFD. In addition, the linear regression analysis also showed good agreement between the displacement force values calculated by the new approach and CFD (R = 0.999). Conclusions: The proposed approach can quickly and accurately calculate the patient-specific displacement force on a stent graft and can therefore help clinicians quickly evaluate the post-EVAR displacement force.
Collapse
|
4
|
Qing M, Qiu Y, Wang J, Zheng T, Yuan D. A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck. Front Physiol 2021; 12:795085. [PMID: 34925075 PMCID: PMC8674644 DOI: 10.3389/fphys.2021.795085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 11/10/2021] [Indexed: 02/05/2023] Open
Abstract
Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations. Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared. Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced. Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis.
Collapse
Affiliation(s)
- Ming Qing
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China
| | - Yue Qiu
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China
| | - Jiarong Wang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Ding Yuan
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| |
Collapse
|
5
|
Wang J, Zhao J, Yuan D. Response to "Re: Midterm Outcomes of Crossed Limb vs. Standard Limb Configuration in Endovascular Abdominal Aortic Aneurysm Repair: A Propensity Score Analysis". Eur J Vasc Endovasc Surg 2021; 62:661-662. [PMID: 34344582 DOI: 10.1016/j.ejvs.2021.06.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 06/25/2021] [Indexed: 02/05/2023]
Affiliation(s)
- Jiarong Wang
- Department of Vascular Surgery, West China Hospital, Sichuan University, China
| | - Jichun Zhao
- Department of Vascular Surgery, West China Hospital, Sichuan University, China
| | - Ding Yuan
- Department of Vascular Surgery, West China Hospital, Sichuan University, China.
| |
Collapse
|
6
|
Wang JL, Wu DH, Li HY, Wang YL. Three-dimensional ophthalmic artery model reconstruction and assessment captured by computed tomographic angiography in non-arteritic anterior ischemic optic neuropathy patients. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:451. [PMID: 33850848 PMCID: PMC8039697 DOI: 10.21037/atm-20-6883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background The ophthalmic artery (OA) was first reconstructed using computer software. The structural differences of ophthalmic arteries in non-arteritic anterior ischemic optic neuropathy (NAION) and normal eyes, in addition to hemodynamic alterations, were assessed. Methods Thirty-one NAION eyes, 19 uninvolved eyes with NAION, and a control group of 26 healthy eyes were retrospectively included. Computed tomographic angiography data were recorded, and corresponding three-dimensional OA models were constructed. Initial OA and internal carotid artery (ICA) diameters and the angle between them were analyzed. Three different OA models were used to evaluate hemodynamic performance. The statistical relationships between the initial diameters of the OA and ICA and the angle between the OA and ICA were described. Results OA diameters in NAION eyes were significantly smaller than those in both uninvolved and healthy eyes (P<0.05). There was no significant difference between uninvolved and healthy eyes (P=0.31). The initial ICA diameter and the angle between the OA and ICA did not significantly differ among the three groups. In the three models, the blood flow velocity in the initial ophthalmic arteries of uninvolved eyes was higher than that in the NAION eyes. The mass flows of the right and left ophthalmic arteries, accounting for the ipsilateral ICA in the control model, were 0.57%. However, these values in uninvolved and NAION eyes were 1.36% and 0.25%, respectively. Conclusions NAION is associated with a smaller initial OA diameter, which may be related to hypoperfusion. To our knowledge, this is the first pilot study to analyze hemodynamic alterations using OA models.
Collapse
Affiliation(s)
- Jia-Lin Wang
- Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Dong-Hui Wu
- Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Hong-Yang Li
- Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Yan-Ling Wang
- Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
7
|
Shen X, Jiang J, Deng Y, Zhu H, Lu K. Haemodynamics Study of Tapered Stents Intervention to Tapered Arteries. Cardiovasc Eng Technol 2019; 10:583-589. [DOI: 10.1007/s13239-019-00437-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 10/04/2019] [Indexed: 10/25/2022]
|