1
|
Shimura M, Mizumoto A, Xia Y, Shimomura Y. Multipoint surface electromyography measurement using bull's-eye electrodes for wide-area topographic analysis. J Physiol Anthropol 2023; 42:24. [PMID: 37891686 PMCID: PMC10612298 DOI: 10.1186/s40101-023-00342-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 10/16/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND Surface electromyography (sEMG) is primarily used to analyze individual and neighboring muscle activity. However, using a broader approach can enable simultaneous measurement of multiple muscles, which is essential for understanding muscular coordination. Using the "bull's-eye electrode," which allows bipolar derivation without directional dependence, enables wide-area multipoint sEMG measurements. This study aims to establish a multipoint measurement system and demonstrate its effectiveness and evaluates forearm fatigue and created topographic maps during a grasping task. METHODS Nine healthy adults with no recent arm injuries or illnesses participated in this study. They performed grasping tasks using their dominant hand, while bull's-eye electrodes recorded their muscle activity. To validate the effectiveness of the system, we calculated the root mean squares of muscle activity and entropy, an indicator of muscle activity distribution, and compared them over time. RESULTS The entropy analysis demonstrated a significant time-course effect with increased entropy over time, suggesting increased forearm muscle uniformity, which is possibly indicative of fatigue. Topographic maps visually displayed muscle activity, revealing notable intersubject variations. DISCUSSION Bull's-eye electrodes facilitated the capture of nine homogeneous muscle activity points, enabling the creation of topographic images. The entropy increased progressively, suggesting an adaptive muscle coordination response to fatigue. Despite some limitations, such as inadequate measurement of the forearm muscles' belly, the system is an unconventional measurement method. CONCLUSION This study established a robust system for wide-area multipoint sEMG measurements using a bull's-eye electrode setup. This system effectively evaluates muscle fatigue and provides a comprehensive topographic view of muscle activity. These results mark a significant step towards developing a future multichannel sEMG system with enhanced measurement points and improved wearability. TRIAL REGISTRATION This study was approved by the Ethics Committee of Chiba University Graduate School of Engineering (acceptance number: R4-12, Acceptance date: November 04, 2022).
Collapse
Affiliation(s)
- Megumi Shimura
- Graduate School of Science and Engineering, Chiba University, 1-33 Yayoi-Cho, Inage-Ku, Chiba City, 2638522, Japan.
| | - Akihiko Mizumoto
- Graduate School of Science and Engineering, Chiba University, 1-33 Yayoi-Cho, Inage-Ku, Chiba City, 2638522, Japan
| | - Yali Xia
- Design Research Institute, Chiba University, 1-33 Yayoi-Cho, Inage-Ku, Chiba City, 2638522, Japan
| | - Yoshihiro Shimomura
- Design Research Institute, Chiba University, 1-33 Yayoi-Cho, Inage-Ku, Chiba City, 2638522, Japan
| |
Collapse
|
2
|
Dolenec A, Svetina M, Strojnik V. Electromyographic Comparison of an Abdominal Rise on a Ball with a Traditional Crunch. SENSORS 2022; 22:s22051979. [PMID: 35271124 PMCID: PMC8915105 DOI: 10.3390/s22051979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 02/20/2022] [Accepted: 03/01/2022] [Indexed: 11/16/2022]
Abstract
We propose a new exercise, the abdominal rise on the ball, to replace the traditional crunch in exercise programs. The aim of this study is to compare the activity of the abdominal muscles when performing an ARB with the same activity when performing a traditional crunch. Twenty healthy adults participated in the study. Surface electromyography (EMG) was recorded from the upper and lower rectus abdominis (URA, LRA), internal oblique (IO), external oblique (EO), transversus abdominis (TrA), and erector spinae (ES). EMG values were normalized to maximal voluntary isometric contraction. A paired t-test, nonparametric Wilcoxon test and correlation coefficient were used for statistical analysis. The normalized EMG values of EO, TrA and ES, were statistically significantly higher during the abdominal rise on the ball compared to the traditional crunch, while URA, LRA and IO were significantly lower during the abdominal rise on the ball compared to the traditional crunch. TrA, EO and IO are sufficiently activated during an abdominal rise on a ball, so the exercise could be deemed effective for strengthening these muscles.
Collapse
|
3
|
Muscle Co-Activation around the Knee during Different Walking Speeds in Healthy Females. SENSORS 2021; 21:s21030677. [PMID: 33498231 PMCID: PMC7863926 DOI: 10.3390/s21030677] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 01/11/2021] [Accepted: 01/16/2021] [Indexed: 11/17/2022]
Abstract
The purpose of this study was to examine the changes in co-activation around the knee joint during different walking speeds in healthy females using the co-activation index. Ten healthy females (age: 21.20 ± 7.21 years, height: 164.00 ± 4.00 cm, mass: 60.60 ± 4.99 kg) participated in this study and performed three walking speeds (slow, normal, and fast). A Qualisys 11-camera motion analysis system sampling at a frequency of 200 Hz was synchronized with a Trigno EMG Wireless system operating at a 2000 Hz sampling frequency. A significant decrease in the co-activation index of thigh muscles was observed between the slow and fast, and between the normal and fast, walking speeds during all walking phases. A non-significant difference was observed between the slow and normal walking speeds during most walking phases, except the second double support phase, during which the difference was significant. A negative relationship was found between walking speed and the co-activation index of thigh muscles in all speeds during walking phases: first double support (r = −0.3386, p < 0.001), single support (r = −0.2144, p < 0.01), second double support (r = −0.4949, p < 0.001), and Swing (r = −0.1639, p < 0.05). In conclusion, the results indicated high variability of thigh muscle co-activation in healthy females during the different walking speeds, and a decrease in the co-activation of the thigh muscles with the increase of speed.
Collapse
|
4
|
Sirisawasd S, Taptagaporn S, Boonshuyar C, Earde P. Comparison of musculoskeletal load using two devices for manual height adjustment of the hospital bed. INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS 2020; 28:519-527. [PMID: 32646297 DOI: 10.1080/10803548.2020.1794563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Objectives. Patient manual handling in bed causes lower back pain (LBP) among Thai nurses. This study aims to develop an extension device for manual height adjustment of the hospital bed, and to evaluate its efficiency in preventing LBP among Thai nurses. Methods. Eleven participants were enrolled for electromyography measurement in eight right muscles. Subsequently, 56 volunteer nurses were recruited by convenience sampling for observational risk assessment by rapid entire body assessment (REBA) and satisfaction evaluation. The characteristics of the participants, percentage of maximum voluntary contraction (%MVC) of each muscle, REBA scores and satisfaction in using the device were analyzed by descriptive statistics, multivariate analysis of variance, paired t test and Wilcoxon signed-rank test, respectively. Results. %MVC values of the six muscles, i.e., biceps brachii, deltoideus, trapezius, latissimus dorsi, erector spinae and hamstring, were found to have a 4-18% decrease. The REBA scores decreased for both left and right when using the extension device, and all participants were more satisfied with the extension device than the hand crank of the hospital bed. Conclusions. The use of the extension device for manual height adjustment of the hospital bed developed from this study helps to prevent LBP among healthcare workers across settings.
Collapse
Affiliation(s)
| | | | | | - Poramet Earde
- Faculty of Allied Health Sciences, Thammasat University, Thailand
| |
Collapse
|
5
|
Vaičienė G, Berškienė K, Slapsinskaite A, Mauricienė V, Razon S. Not only static: Stabilization manoeuvres in dynamic exercises - A pilot study. PLoS One 2018; 13:e0201017. [PMID: 30089127 PMCID: PMC6082523 DOI: 10.1371/journal.pone.0201017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 07/06/2018] [Indexed: 12/19/2022] Open
Abstract
This study examined characteristics of trunk muscles electrical activity in young adults performed in the course of static and dynamic trunk muscles strengthening exercises using different lumbar spine stabilization manoeuvres. Twenty young adults (Mage = 25.5 SD = 2.91) participated in this study. Of the 20, 11 subjects (5 males and 6 females) reported no history of pain, 9 subjects (5 males and 4 females) reported lower back pain (LBP) within the last three months. Subjects performed lumbar spine stabilization manoeuvres (abdominal bracing (AB) and abdominal hollowing (AH)) with static and dynamic abdominal muscles strengthening exercises (i.e., plank, side-bridges, and curl-ups). Noraxon Telemyo twelve channel electromyography device (Noraxon USA, Inc.) was used to record EMG data from rectus abdominal muscle (RA), external oblique muscles (EO), internal oblique muscles (IO), and erector spine muscles (ES). In static exercises such as side-bridge exercise, significantly higher RA muscle electrical activity was recorded with AB manoeuvre compared to AH manoeuvre both on the right side and left side respectively (Z = -2.17; p = 0.03; Z = 3.40; p = 0.001). In dynamic exercises such as curl-up exercise, during the lifting phase, median value of RA muscle activity with AB was significantly higher than with AH (Z = -2.315; p = 0.021). Median value of IO muscles activity with AH was significantly higher than with AB (Z = -3.230; p = 0.001). Our findings indicated that although surface muscles are more activated with AB manoeuvre exercises, deep abdominal muscles are more activated in exercises with AH manoeuvre. These findings can help practitioners design interventions to integrate AH manoeuvre for benefiting persons with lumbar instability.
Collapse
Affiliation(s)
- Giedrė Vaičienė
- Institute of Sports, Lithuanian University of Health Sciences (LUHS), Kaunas, Lithuania
| | - Kristina Berškienė
- Institute of Sports, Lithuanian University of Health Sciences (LUHS), Kaunas, Lithuania
| | - Agne Slapsinskaite
- Institute of Sports, Lithuanian University of Health Sciences (LUHS), Kaunas, Lithuania
- Health Research Institute, LUHS, Kaunas, Lithuania
- * E-mail:
| | - Vilma Mauricienė
- Institute of Sports, Lithuanian University of Health Sciences (LUHS), Kaunas, Lithuania
| | - Selen Razon
- Department of Kinesiology, West Chester University, West Chester, PA, United States of America
| |
Collapse
|
6
|
Du W, Li H, Omisore OM, Wang L, Chen W, Sun X. Co-contraction characteristics of lumbar muscles in patients with lumbar disc herniation during different types of movement. Biomed Eng Online 2018; 17:8. [PMID: 29361944 PMCID: PMC5781330 DOI: 10.1186/s12938-018-0443-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 01/16/2018] [Indexed: 01/24/2023] Open
Abstract
Background Muscular performance is an important factor for the mechanical stability of lumbar spine in humans, in which, the co-contraction of lumbar muscles plays a key role. We hypothesized that when executing different daily living motions, the performance of the lumbar muscle co-contraction stabilization mechanism varies between patients with lumbar disc herniation (LDH) and healthy controls. Hence, in this study, co-contraction performance of lumbar muscles between patients with LDH and healthy subjects was explored to check if there are significant differences between the two groups when performing four representative movements. Methods Twenty-six LDH patients (15 females, 11 males) and a control group of twenty-eight subjects (16 females, 12 males) were recruited. Surface electromyography (EMG) signals were recorded from the external oblique, lumbar multifidus, and internal oblique/transversus abdominis muscles during the execution of four types of movement, namely: forward bending, backward bending, left lateral flexion and right lateral flexion. The acquired EMG signals were segmented, and wavelet decomposition was performed followed by reconstruction of the low-frequency components of the signal. Then, the reconstructed signals were used for further analysis. Co-contraction ratio was employed to assess muscle coordination and compare it between the LDH patients and healthy controls. The corresponding signals of the subjects in the two groups were compared to evaluate the differences in agonistic and antagonistic muscle performance during the different motions. Also, sample entropy was applied to evaluate complexity changes in lumbar muscle recruitment during the movements. Results Significant differences between the LDH and control groups were found in the studied situations (p < 0.05). During the four movements considered in this study, the participants of the LDH group exhibited a higher level of co-contraction ratio, lower agonistic, and higher antagonistic lumbar muscle activity (p < 0.01) than those of the control group. Furthermore, the co-contraction ratio of LDH patients was dominated by the antagonistic muscle activity during the movements, except for the forward bending motion. However, in the healthy control group, the agonistic muscle activity contributed more to the co-contraction ratio with an exception for the backward bending motion. Conversely, the sample entropy value was significantly lower for agonistic muscles of LDH group compared to the control group (p < 0.01) while the entropy value was significantly greater in antagonistic muscles (p < 0.01) during the four types of movement, respectively. Conclusions Lumbar disc herniation patients exhibited numerous variations in the evaluated parameters that reflect the co-contraction of lumbar muscles, the agonistic and antagonistic muscle activities, and their respective sample entropy values when compared with the healthy control group. These variations could be due to the compensation mechanism that was required to stabilize the spine. The results of this study could facilitate the design of efficient rehabilitation methods for treatment of lumbar muscle dysfunctions.
Collapse
Affiliation(s)
- Wenjing Du
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China
| | - Huihui Li
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China
| | - Olatunji Mumini Omisore
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Lei Wang
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.
| | - Wenmin Chen
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Jiangxi University of Science and Technology, Jiangxi, China
| | - Xiangjun Sun
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Boulevard, University Town of Shenzhen, Xili Nanshan, Shenzhen, 518055, China.,Jiangxi University of Science and Technology, Jiangxi, China
| |
Collapse
|