1
|
Ladisich B, Machegger L, Romagna A, Krainz H, Steinbacher J, Leitinger M, Kalss G, Thon N, Trinka E, Winkler PA, Schwartz C. VarioGuide® frameless neuronavigation-guided stereoelectroencephalography in adult epilepsy patients: technique, accuracy and clinical experience. Acta Neurochir (Wien) 2021; 163:1355-1364. [PMID: 33580853 PMCID: PMC8053662 DOI: 10.1007/s00701-021-04755-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 02/01/2021] [Indexed: 12/12/2022]
Abstract
Background Stereoelectroencephalography (SEEG) allows the identification of deep-seated seizure foci and determination of the epileptogenic zone (EZ) in drug-resistant epilepsy (DRE) patients. We evaluated the accuracy and treatment-associated morbidity of frameless VarioGuide® (VG) neuronavigation-guided depth electrode (DE) implantations. Methods We retrospectively identified all consecutive adult DRE patients, who underwent VG-neuronavigation DE implantations, between March 2013 and April 2019. Clinical data were extracted from the electronic patient charts. An interdisciplinary team agreed upon all treatment decisions. We performed trajectory planning with iPlan® Cranial software and DE implantations with the VG system. Each electrode’s accuracy was assessed at the entry (EP), the centre (CP) and the target point (TP). We conducted correlation analyses to identify factors associated with accuracy. Results The study population comprised 17 patients (10 women) with a median age of 32.0 years (range 21.0–54.0). In total, 220 DEs (median length 49.3 mm, range 25.1–93.8) were implanted in 21 SEEG procedures (range 3–16 DEs/surgery). Adequate signals for postoperative SEEG were detected for all but one implanted DEs (99.5%); in 15/17 (88.2%) patients, the EZ was identified and 8/17 (47.1%) eventually underwent focus resection. The mean deviations were 3.2 ± 2.4 mm for EP, 3.0 ± 2.2 mm for CP and 2.7 ± 2.0 mm for TP. One patient suffered from postoperative SEEG-associated morbidity (i.e. conservatively treated delayed bacterial meningitis). No mortality or new neurological deficits were recorded. Conclusions The accuracy of VG-SEEG proved sufficient to identify EZ in DRE patients and associated with a good risk-profile. It is a viable and safe alternative to frame-based or robotic systems. Supplementary Information The online version contains supplementary material available at 10.1007/s00701-021-04755-w.
Collapse
Affiliation(s)
- Barbara Ladisich
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, A-5020, Salzburg, Austria
| | - Lukas Machegger
- University Institute of Neuroradiology, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Alexander Romagna
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, A-5020, Salzburg, Austria
- Department of Neurosurgery, München Klinik Bogenhausen, Englschalkingerstr. 77, 81925, Munich, Germany
| | - Herbert Krainz
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, A-5020, Salzburg, Austria
| | - Jürgen Steinbacher
- University Institute of Neuroradiology, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Markus Leitinger
- Department of Neurology, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Gudrun Kalss
- Department of Neurology, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Niklas Thon
- Department of Neurosurgery, University Hospital Munich, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Eugen Trinka
- Department of Neurology, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Peter A Winkler
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, A-5020, Salzburg, Austria
| | - Christoph Schwartz
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University Salzburg, Ignaz-Harrer-Str. 79, A-5020, Salzburg, Austria.
| |
Collapse
|
2
|
Vakharia VN, Sparks R, Rodionov R, Vos SB, Dorfer C, Miller J, Nilsson D, Tisdall M, Wolfsberger S, McEvoy A, Miserocchi A, Winston GP, O’Keeffe AG, Ourselin S, Duncan JS. Computer-assisted planning for the insertion of stereoelectroencephalography electrodes for the investigation of drug-resistant focal epilepsy: an external validation study. J Neurosurg 2018; 130:601-610. [PMID: 29652234 PMCID: PMC6076995 DOI: 10.3171/2017.10.jns171826] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 10/02/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVE One-third of cases of focal epilepsy are drug refractory, and surgery might provide a cure. Seizure-free outcome after surgery depends on the correct identification and resection of the epileptogenic zone. In patients with no visible abnormality on MRI, or in cases in which presurgical evaluation yields discordant data, invasive stereoelectroencephalography (SEEG) recordings might be necessary. SEEG is a procedure in which multiple electrodes are placed stereotactically in key targets within the brain to record interictal and ictal electrophysiological activity. Correlating this activity with seizure semiology enables identification of the seizure-onset zone and key structures within the ictal network. The main risk related to electrode placement is hemorrhage, which occurs in 1% of patients who undergo the procedure. Planning safe electrode placement for SEEG requires meticulous adherence to the following: 1) maximize the distance from cerebral vasculature, 2) avoid crossing sulcal pial boundaries (sulci), 3) maximize gray matter sampling, 4) minimize electrode length, 5) drill at an angle orthogonal to the skull, and 6) avoid critical neurological structures. The authors provide a validation of surgical strategizing and planning with EpiNav, a multimodal platform that enables automated computer-assisted planning (CAP) for electrode placement with user-defined regions of interest. METHODS Thirteen consecutive patients who underwent implantation of a total 116 electrodes over a 15-month period were studied retrospectively. Models of the cortex, gray matter, and sulci were generated from patient-specific whole-brain parcellation, and vascular segmentation was performed on the basis of preoperative MR venography. Then, the multidisciplinary implantation strategy and precise trajectory planning were reconstructed using CAP and compared with the implemented manually determined plans. Paired results for safety metric comparisons were available for 104 electrodes. External validity of the suitability and safety of electrode entry points, trajectories, and target-point feasibility was sought from 5 independent, blinded experts from outside institutions. RESULTS CAP-generated electrode trajectories resulted in a statistically significant improvement in electrode length, drilling angle, gray matter-sampling ratio, minimum distance from segmented vasculature, and risk (p < 0.05). The blinded external raters had various opinions of trajectory feasibility that were not statistically significant, and they considered a mean of 69.4% of manually determined trajectories and 62.2% of CAP-generated trajectories feasible; 19.4% of the CAP-generated electrode-placement plans were deemed feasible when the manually determined plans were not, whereas 26.5% of the manually determined electrode-placement plans were rated feasible when CAP-determined plans were not (no significant difference). CONCLUSIONS CAP generates clinically feasible electrode-placement plans and results in statistically improved safety metrics. CAP is a useful tool for automating the placement of electrodes for SEEG; however, it requires the operating surgeon to review the results before implantation, because only 62% of electrode-placement plans were rated feasible, compared with 69% of the manually determined placement plans, mainly because of proximity of the electrodes to unsegmented vasculature. Improved vascular segmentation and sulcal modeling could lead to further improvements in the feasibility of CAP-generated trajectories.
Collapse
Affiliation(s)
- Vejay N. Vakharia
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
- National Hospital for Neurology and Neurosurgery, Queen Square, London
| | - Rachel Sparks
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
| | - Roman Rodionov
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
- National Hospital for Neurology and Neurosurgery, Queen Square, London
| | - Sjoerd B. Vos
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
- Transitional Imaging Group, Centre for Medical Image Computing, University College London
| | - Christian Dorfer
- Department of Neurosurgery, Medical University Vienna - General Hospital (AKH) Waehringer Guertel 18-20, Vienna, Austria
| | - Jonathan Miller
- Department of Neurological Surgery, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Daniel Nilsson
- Institute of Neuroscience and Physiology, Sahlgrenska Academy, Gothenburg University, Göteborg, Sweden
| | - Martin Tisdall
- Great Ormond Street Hospital, UCL Great Ormond Street Institute of Child Health
| | - Stefan Wolfsberger
- Department of Neurosurgery, Medical University Vienna - General Hospital (AKH) Waehringer Guertel 18-20, Vienna, Austria
| | - Andrew McEvoy
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- National Hospital for Neurology and Neurosurgery, Queen Square, London
| | - Anna Miserocchi
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
| | - Gavin P Winston
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
- National Hospital for Neurology and Neurosurgery, Queen Square, London
| | | | - Sebastien Ourselin
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
| | - John S Duncan
- Department of Clinical and Experimental Epilepsy, UCL Institute of Neurology, National Hospital for Neurology and Neurosurgery
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
- National Hospital for Neurology and Neurosurgery, Queen Square, London
| |
Collapse
|
3
|
Leung CH, Kliem MA, Heeke BL, McPhee SWJ, Federici T, Snyder BR, Boulis NM. Assessment of hippocampal adeno-associated viral vector gene delivery via frameless stereotaxis in a nonhuman primate. Stereotact Funct Neurosurg 2011; 89:275-85. [PMID: 21849811 DOI: 10.1159/000328265] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2010] [Accepted: 04/07/2011] [Indexed: 11/19/2022]
Abstract
BACKGROUND/AIMS Expression of the neuropeptide galanin in hippocampal neurons reduces seizures in the kainic acid rodent model of epilepsy. In order to translate these findings into a human clinical trial, the safety and feasibility of hippocampal adeno-associated viral (AAV) vector expression must be demonstrated in a nonhuman primate model. METHODS The Stealth Frameless Stereotactic System and Navigus Biopsy Appliance (Medtronic) were used to inject self-complementary AAV2 carrying the gene for green fluorescent protein (GFP) into monkey hippocampi. Using a single occipital trajectory per side (n = 8 trajectories), multiple injections spaced by 5 mm were delivered to each hippocampus. RESULTS GFP was expressed in both neuronal and glial cells. Injections led to nonhomogeneous gene expression, suggesting closer spacing of injections may lead to more gene expression. Increasing injection volumes entailed a general increase in volume of expression, but there was no overlap of expression within the 5-mm injection interval. Efforts to avoid the occipital horn failed to prevent leaking of vector into the ventricle, and resulted in deviation of the trajectory at proximal points from the hippocampus. CONCLUSION Using the occipital approach, adequate cannulation of the monkey hippocampus will require transventricular trajectories.
Collapse
Affiliation(s)
- Cary H Leung
- Department of Neurosurgery, Emory University School of Medicine, Atlanta, GA 30322, USA
| | | | | | | | | | | | | |
Collapse
|
4
|
Reddy CG, Dahdaleh NS, Albert G, Chen F, Hansen D, Nourski K, Kawasaki H, Oya H, Howard MA. A method for placing Heschl gyrus depth electrodes. J Neurosurg 2010; 112:1301-7. [PMID: 19663547 DOI: 10.3171/2009.7.jns09404] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A wide range of devices is used to obtain intracranial electrocorticography recordings in patients with medically refractory epilepsy, including subdural strip and grid electrodes and depth electrodes. Penetrating depth electrodes are required to access some brain regions, and 1 target site that presents a particular technical challenge is the first transverse temporal gyrus, or Heschl gyrus (HG). The HG is located within the supratemporal plane and has an oblique orientation relative to the sagittal and coronal planes. Large and small branches of the middle cerebral artery abut the pial surface of the HG and must be avoided when planning the electrode trajectory. Auditory cortex is located within the HG, and there are functional connections between this dorsal temporal lobe region and medial sites commonly implicated in the pathophysiology of temporal lobe epilepsy. At some surgical centers, depth electrodes are routinely placed within the supratemporal plane, and the HG, in patients who require intracranial electrocorticography monitoring for presumed temporal lobe epilepsy. Information from these recordings is reported to facilitate the identification of seizure patterns in patients with or without auditory auras. To date, only one implantation method has been reported to be safe and effective for placing HG electrodes in a large series of patients undergoing epilepsy surgery. This well-established approach involves inserting the electrodes from a lateral trajectory while using stereoscopic stereotactic angiography to avoid vascular injury. In this report, the authors describe an alternative method for implantation. They use frameless stereotaxy and an oblique insertion trajectory that does not require angiography and allows for the simultaneous placement of subdural grid arrays. Results in 19 patients demonstrate the safety and efficacy of the method.
Collapse
Affiliation(s)
- Chandan G Reddy
- Department of Neurosurgery, University of Iowa, Iowa City, Iowa, USA
| | | | | | | | | | | | | | | | | |
Collapse
|