1
|
Gulizia M, Ding S, Sá Dos Reis C, Jaques C, Dromain C. Adjustments of iodinated contrast media using lean body weight for abdominopelvic computed tomography: A systematic review and meta-analysis. Eur J Radiol 2024; 178:111631. [PMID: 39029240 DOI: 10.1016/j.ejrad.2024.111631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 06/27/2024] [Accepted: 07/14/2024] [Indexed: 07/21/2024]
Abstract
PURPOSE This systematic review aimed to compare the effect of contrast media (CM) dose adjustment based on lean body weight (LBW) method versus other calculation protocols for abdominopelvic CT examinations. METHOD Studies published from 2002 onwards were systematically searched in June 2024 across Medline, Embase, CINAHL, Cochrane CENTRAL, Web of Science, Google Scholar and four other grey literature sources, with no language limit. Randomised controlled trials (RCT) and quasi-RCT of abdominopelvic or abdominal CT examinations in adults with contrast media injection for oncological and acute diseases were included. The comparators were other contrast dose calculation methods such as total body weight (TBW), fixed volume (FV), body surface area (BSA), and blood volume. The main outcomes considered were liver and aortic enhancement. Titles, abstracts and full texts were independently screened by two reviewers. RESULTS Eight studies were included from a total of 2029 articles identified. Liver parenchyma and aorta contrast enhancement did not significantly differ between LBW and TBW protocols (p = 0.07, p = 0.06, respectively). However, the meta-analysis revealed significantly lower contrast volume injected with LBW protocol when compared to TBW protocol (p = 0.003). No statistical differences were found for contrast enhancement and contrast volume between LBW and the other strategies. CONCLUSION Calculation of the CM dosage based on LBW allows a reduction in the injected volume for abdominopelvic CT examination, ensuring the same image quality in terms of contrast enhancement.
Collapse
Affiliation(s)
- Marianna Gulizia
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland.
| | - Sandrine Ding
- School of Health Sciences HESAV, HES-SO, University of Applied Sciences Western Switzerland, Avenue de Beaumont 21, 1011 Lausanne, Switzerland; Bureau d'Echange des Savoirs pour des praTiques exemplaires de soins (BEST) a JBI Center of Excellence, Avenue Vinet 30, 1004 Lausanne, Switzerland.
| | - Cláudia Sá Dos Reis
- School of Health Sciences HESAV, HES-SO, University of Applied Sciences Western Switzerland, Avenue de Beaumont 21, 1011 Lausanne, Switzerland.
| | - Cécile Jaques
- Bureau d'Echange des Savoirs pour des praTiques exemplaires de soins (BEST) a JBI Center of Excellence, Avenue Vinet 30, 1004 Lausanne, Switzerland; Medical Library, Lausanne University Hospital and University of Lausanne, Lausanne, CH, Switzerland.
| | - Clarisse Dromain
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland.
| |
Collapse
|
2
|
Varughese NA, Panakkal NC, Nair VT, Kadavigere R, Lakshmi V, Sukumar S. Effect of patient characteristics on aortic attenuation in iodinated contrast-enhanced Abdominopelvic CT: A retrospective study. Radiography (Lond) 2024; 30 Suppl 1:94-101. [PMID: 39106556 DOI: 10.1016/j.radi.2024.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 07/19/2024] [Accepted: 07/22/2024] [Indexed: 08/09/2024]
Abstract
INTRODUCTION Contrast Enhanced Computed Tomography (CECT) abdomen and pelvis is a common imaging procedure. Hospitals typically follow fixed protocols of contrast volume administration for triple-phase CECT abdomen and pelvis scans and have found that patients are either underdosed or overdosed with respect to their body habitus. The aim of the study was to correlate different patient characteristics such as Total body weight (TBW), Lean Body Mass (LBM), Body Mass Index (BMI), Body Surface Area (BSA) and Blood Volume (BV) with aortic enhancement in the arterial and portal venous phases for CECT Abdomen and pelvis. METHODS A total of 106 patients who underwent triple-phase CECT abdomen & pelvis were retrospectively studied. A circular region-of-interest (ROI) of 100 mm2 was positioned on descending aorta for unenhanced, arterial, and portal venous phases to measure the aortic enhancement in Hounsfield's units. Measure of contrast attenuation (ΔH) was calculated from the difference of CT values on unenhanced images and contrast images. Correlation analysis was performed to evaluate the relation of patient body characteristics with aortic enhancement. RESULTS Correlation analysis revealed that BMI exhibited the least correlation when compared to the other characteristics in both arterial (r = -0.3; p = 0.002) and portovenous phases (r = -0.35; p < 0.001) whereas TBW, LBW, BSA and BV reported moderate inverse correlations. BV was found to be the strongest of all characteristics under linear regression. CONCLUSION The study supports the use of protocols that adjust contrast volume to either TBW, LBW, BSA, or BV for CT abdomen and pelvis scan. IMPLICATION OF PRACTICE The right body parameter ensures optimal contrast enhancement, improving the visualization of anatomical structures and helps in adapting tailored contrast injection protocols.
Collapse
Affiliation(s)
- N A Varughese
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - N C Panakkal
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - V T Nair
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - R Kadavigere
- Radio-diagnosis & Imaging, Department of Radio Diagnosis & Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - V Lakshmi
- Department of Data Sciences, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - S Sukumar
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| |
Collapse
|
3
|
Henning MK, Gunn C, Arenas-Jiménez J, Johansen S. Strategies for calculating contrast media dose for chest CT. Eur Radiol Exp 2023; 7:29. [PMID: 37303003 DOI: 10.1186/s41747-023-00345-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 04/13/2023] [Indexed: 06/13/2023] Open
Abstract
BACKGROUND Total body weight (TBW) is a frequently used contrast media (CM) strategy for dose calculation in enhanced CT, yet it is suboptimal as it lacks consideration of patient characteristics, such as body fat percentage (BFP) and muscle mass. Alternative CM dosage strategies are suggested by the literature. Our objectives were to analyze the CM dose impact when adjusting to body composition using methods of obtaining lean body mass (LBM) and body surface area (BSA) along with its correlation with demographic factors in contrast enhanced chest CT examinations. METHODS Eighty-nine adult patients referred for CM thoracic CT were retrospectively included, categorized as either normal, muscular, or overweight. Patient body composition data was used to calculate the CM dose according to LBM or BSA. LBM was calculated with the James method, Boer method, and bioelectric impedance (BIA). BSA was calculated using the Mostellar formula. We then correlated the corresponding CM doses with demographic factors. RESULTS BIA demonstrated the highest and lowest calculated CM dose in muscular and overweight groups respectively, compared to other strategies. For the normal group, the lowest calculated CM dose was achieved using TBW. The calculated CM dose was more closely correlated with BFP using the BIA method. CONCLUSIONS The BIA method is more adaptive to variations in patient body habitus especially in muscular and overweight patients and is most closely correlated to patient demographics. This study could support utilizing the BIA method for calculating LBM for a body-tailored CM dose protocol for enhanced chest CT examinations. RELEVANCE STATEMENT The BIA-based method is adaptive to variations in body habitus especially in muscular and overweight patients and is closely correlated to patient demographics for contrast-enhanced chest CT. KEY POINTS • Calculations based on BIA showed the largest variation in CM dose. • Lean body weight using BIA demonstrated the strongest correlation to patient demographics. • Lean body weight BIA protocol may be considered for CM dosing in chest CT.
Collapse
Affiliation(s)
- Mette Karen Henning
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Catherine Gunn
- School of Health Sciences, Dalhousie University, Halifax, Canada
| | - Juan Arenas-Jiménez
- Department of Radiology, Dr. Balmis General University Hospital, Alicante, Spain
- Department of Pathology and Surgery, Miguel Hernández University, Alicante, Spain
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain
| | - Safora Johansen
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway.
- Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway.
| |
Collapse
|
4
|
Kesen S, Svensson A, Thor D, Brismar TB. Hepatic enhancement at computed tomography: is there a dependence on body weight past institutional contrast dosing limits? Acta Radiol 2023; 64:435-440. [PMID: 35266404 PMCID: PMC9905147 DOI: 10.1177/02841851221079014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Although described in product monographs, the maximum contrast media (CM) dose at computed tomography (CT) varies among institutions. PURPOSE To investigate whether an upper limit of 40 g of iodine in women and 50 g in men is sufficient or if there is a body weight (BW) dependence of mean hepatic enhancement (MHE) beyond those thresholds. MATERIAL AND METHODS At our institution, CM injection duration is fixed to 30 s and dosed 600 mg iodine/kg up to 40 g in women and 50 g in men. Pre- and post-contrast hepatic attenuation values (HU) were retrospectively obtained in 200 women and 200 men with glomerular filtration rate >45 mL/min undergoing 18-flurodeoxyglucose PET-CT (18F-FDG PET-CT) of which half weighed below and half above those dose thresholds using iodixanol 320 mg iodine/mL or iomeprol 400 mg iodine/mL. The correlation between BW and MHE was assessed by simple linear regression. RESULTS Weight range was 41-120 kg in women and 47-137 kg in men. There was no significant relationship between MHE and BW in women receiving <40 g (r = -0.05, P = 0.63) or in men receiving <50 g (r = 0.18, P = 0.07). Above those thresholds there was an inverse relationship (r = -0.64, P<0.001 in women and r = -0.30, P<0.002 in men). There was no apparent upper limit where the dependence of hepatic MHE on BW decreased. Hepatosteatosis limited MHE. CONCLUSION Adjusting CM to BW diminishes the dependence of MHE on BW. There was no apparent upper limit for the relationship between BW and MHE in heavier patients at CM-enhanced CT.
Collapse
Affiliation(s)
- Savas Kesen
- Division of Radiology, Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden,Department of Radiology, Södersjukhuset, Stockholm, Sweden,Savas Kesen, Division of Radiology, Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden and Södersjukhuset, Department of Radiology, Stockholm, Sweden.
| | - Anders Svensson
- Division of Radiology, Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden,Department of Radiology, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden
| | - Daniel Thor
- Medical Radiation Physics and Nuclear Medicine, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden
| | - Torkel B. Brismar
- Division of Radiology, Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden,Department of Radiology, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
5
|
Henning MK, Aaløkken TM, Johansen S. Contrast medium protocols in routine chest CT: a survey study. Acta Radiol 2022; 63:351-359. [PMID: 33648351 DOI: 10.1177/0284185121997111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Administration of contrast medium (CM) is an important image quality factor in computed tomography (CT) of the chest. There is no clear evidence or guidelines on CM strategies for chest CT, thus a consensus approach is needed. PURPOSE To survey the potential impact on differences in chest CT protocols, with emphasis on strategies for the administration of CM. MATERIAL AND METHODS A total of 170 respondents were included in this survey, which used two different approaches: (i) an online survey was sent to the members of the European Society of Thoracic Imaging (ESTI); and (ii) an email requesting a copy of their CT protocol was sent to all hospitals in Norway, and university hospitals in Sweden and Denmark. The survey focused on factors affecting CM protocols and enhancement in chest CT. RESULTS The overall response rate was 24% (n = 170): 76% of the respondents used a CM concentration of ≥350 mgI/mL; 52% of the respondents used a fixed CM volume strategy. Fixed strategies for injection rate and delay were also the most common approach, practiced by 73% and 57% of the respondents, respectively. The fixed delay was in the range of 20-90 s. Of the respondents, 56% used flexible tube potential strategies (kV). CONCLUSION The chest CT protocols and CM administration strategies employed by the respondents vary widely, affecting the image quality. The results of this study underline the need for further research and consensus guidelines related to chest CT.
Collapse
Affiliation(s)
- Mette Karen Henning
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - Trond Mogens Aaløkken
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
- Faulty of Medicine, University of Oslo, Oslo, Norway
| | - Safora Johansen
- Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
6
|
Zanardo M, Doniselli FM, Esseridou A, Agrò M, Panarisi NAR, Monti CB, Di Leo G, Sardanelli F. Lean body weight versus total body weight to calculate the iodinated contrast media volume in abdominal CT: a randomised controlled trial. Insights Imaging 2020; 11:132. [PMID: 33296036 PMCID: PMC7726088 DOI: 10.1186/s13244-020-00920-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 10/07/2020] [Indexed: 12/25/2022] Open
Abstract
Objectives Iodinated contrast media (ICM) could be more appropriately dosed on patient lean body weight (LBW) than on total body weight (TBW). Methods After Ethics Committee approval, trial registration NCT03384979, patients aged ≥ 18 years scheduled for multiphasic abdominal CT were randomised for ICM dose to LBW group (0.63 gI/kg of LBW) or TBW group (0.44 gI/kg of TBW). Abdominal 64-row CT was performed using 120 kVp, 100–200 mAs, rotation time 0.5 s, pitch 1, Iopamidol (370 mgI/mL), and flow rate 3 mL/s. Levene, Mann–Whitney U, and χ2 tests were used. The primary endpoint was liver contrast enhancement (LCE). Results Of 335 enrolled patients, 17 were screening failures; 44 dropped out after randomisation; 274 patients were analysed (133 LBW group, 141 TBW group). The median age of LBW group (66 years) was slightly lower than that of TBW group (70 years). Although the median ICM-injected volume was comparable between groups, its variability was larger in the former (interquartile range 27 mL versus 21 mL, p = 0.01). The same was for unenhanced liver density (IQR 10 versus 7 HU) (p = 0.02). Median LCE was 40 (35–46) HU in the LBW group and 40 (35–44) HU in the TBW group, without significant difference for median (p = 0.41) and variability (p = 0.23). Suboptimal LCE (< 40 HU) was found in 64/133 (48%) patients in the LBW group and 69/141 (49%) in the TBW group, but no examination needed repeating. Conclusions The calculation of the ICM volume to be administered for abdominal CT based on the LBW does not imply a more consistent LCE.
Collapse
Affiliation(s)
- Moreno Zanardo
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milan, Italy.
| | - Fabio Martino Doniselli
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milan, Italy.,Neuroradiology Department, Foundation IRCCS Neurological Institute "C. Besta", Via Celoria 11, 20133, Milan, Italy
| | - Anastassia Esseridou
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Massimiliano Agrò
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Nicol Antonina Rita Panarisi
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Caterina Beatrice Monti
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milan, Italy
| | - Giovanni Di Leo
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Francesco Sardanelli
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milan, Italy.,Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| |
Collapse
|
7
|
Hibino T, Ichikawa K, Fang Y, Ito S, Kawashima H, Bae KT. Determination of contrast medium dose for hepatic CT enhancement with improved body size dependency using a non-linear analysis based on pharmacokinetic principles. Clin Radiol 2019; 75:238.e11-238.e19. [PMID: 31679815 DOI: 10.1016/j.crad.2019.09.140] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 09/11/2019] [Indexed: 10/25/2022]
Abstract
AIM To propose a pharmacokinetic non-linear analysis method to determine contrast medium (CM) dose for computed tomography (CT) hepatic enhancement to improve body size dependency and validate the proposed CM dose determination method through a clinical study. MATERIALS AND METHODS Enhancement data of 105 patients who underwent hepatic dynamic CT with a fixed CM dose were analysed. From the analysis results, CM doses as a function of each of four body size indices (body weight [BW], lean body weight [LBW], blood volume [BV], and body surface area [BSA]) for achieving improved body size dependency were determined (proposed method), and the body size dependencies were simulated using the enhancement data from 105 patients. The proposed method was validated with a two-arm clinical study on BW. Body size dependency was evaluated using p-value of correlation coefficient between Body size indices and enhancements (p<0.05: significant dependency) and mean absolute error (MAE). RESULTS The simulation showed that significant body size dependencies not considered by the conventional method can be improved by the proposed method. MAEs of BW, LBW, and BV were also significantly reduced (p<0.05). The clinical study with BW demonstrated a similar improvement to that in the simulation result. MAE was also significantly reduced (p<0.001). CONCLUSION The proposed method demonstrated more improved BW, LBW, and BV dependence compared to the conventional method. Through the two-arm clinical study, the proposed method using BW only, without height information, is a suitable index for improving body size dependency.
Collapse
Affiliation(s)
- T Hibino
- Department of Radiological Technology, Daiyukai General Hospital, 1-9-9 Sakura, Ichinomiya, Aichi, 491-8551, Japan; Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| | - K Ichikawa
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
| | - Y Fang
- MIMOSA Diagnostics, 1 Yonge St, Toronto, M5E1E5, Canada
| | - S Ito
- Department of Radiology, Daiyukai General Hospital, 1-9-9 Sakura, Ichinomiya, Aichi, 491-8551, Japan
| | - H Kawashima
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| | - K T Bae
- Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave, Pittsburgh, PA, 15213, USA
| |
Collapse
|
8
|
Peet K, Clarke SE, Costa AF. Hepatic enhancement differences when dosing iodinated contrast media according to total versus lean body weight. Acta Radiol 2019; 60:807-814. [PMID: 30227724 DOI: 10.1177/0284185118801137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Kris Peet
- Department of Diagnostic Radiology, Queen Elizabeth II Health Sciences Centre and Dalhousie University, Halifax, NS, Canada
| | - Sharon E Clarke
- Department of Diagnostic Radiology, Queen Elizabeth II Health Sciences Centre and Dalhousie University, Halifax, NS, Canada
| | - Andreu F Costa
- Department of Diagnostic Radiology, Queen Elizabeth II Health Sciences Centre and Dalhousie University, Halifax, NS, Canada
| |
Collapse
|
9
|
Svensson A, Thor D, Fischer MA, Brismar T. Dual source abdominal computed tomography: the effect of reduced X-ray tube voltage and intravenous contrast media dosage in patients with reduced renal function. Acta Radiol 2019; 60:293-300. [PMID: 29933715 DOI: 10.1177/0284185118783213] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND X-ray tube voltage (kVp) reduction increases intravenous contrast medium (CM) attenuation at computed tomography (CT), but tube output limits its use in large patients. PURPOSE To evaluate the feasibility and image quality of reducing CM dose by low kVp and using dual X-ray source at liver CT. MATERIAL AND METHODS Patients with estimated glomerular filtration rate (eGFR) < 45 mL/min (n = 43) aged 60-91 years (75 ± 7.7), weighing 42-114 kg (75 ± 15) were prospectively scanned using a reduced CM dose of 0.25 or 0.3 g iodine (I)/kg with 70 or 80 kVp respectively, using either single-source or dual-source CT depending on patient size. Liver contrast-to-noise ratio (CNR), liver noise, and muscle noise were quantitatively compared with those of 43 consecutive patients aged > 65 years with eGFR > 45 mL/min scanned using a standard abdominal protocol at 120 kVp after receiving 0.5 gI/kg. RESULTS There was no statistically significant difference in CNR, liver noise, or muscle noise at reduced CM protocols compared to the standard protocol: CNR was 4.6 (95% CI = 4.2-5.0) vs. 5.0 (95% CI = 4.5-5.5), liver noise was 11.1 (95% CI = 10.7-11.6) vs. 11.0 (95% CI = 10.5-11.6), muscle noise was 11.7 (95% CI = 11.2-12.1) vs. 10.8 (95% CI = 10.1-11.4). The mean SSDE was 70% higher with the reduced CM protocol. CONCLUSION CM dosage can be reduced by 40-50% with maintained measured noise and CNR in patients with BMIs of 15-36 kg/m2 by lowering the tube voltage and dual-source CT scanning of the liver.
Collapse
Affiliation(s)
- Anders Svensson
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden
| | - Daniel Thor
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm Sweden
| | - Michael A Fischer
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Torkel Brismar
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden
| |
Collapse
|
10
|
Comparison of Abdominal Computed Tomographic Enhancement and Organ Lesion Depiction Between Weight-Based Scanner Software Contrast Dosing and a Fixed-Dose Protocol in a Tertiary Care Oncologic Center. J Comput Assist Tomogr 2019; 43:155-162. [PMID: 30211799 DOI: 10.1097/rct.0000000000000789] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE This study aimed to evaluate the quality of enhancement and solid-organ lesion depiction using weight-based intravenous (IV) contrast dosing calculated by injector software versus fixed IV contrast dose in oncologic abdominal computed tomographic (CT) examinations. METHODS This institutional review board-exempt retrospective cohort study included 134 patients who underwent single-phase abdominal CT before and after implementation of weight-based IV contrast injector software. Patient weight, height, body mass index, and body surface area were determined. Two radiologists qualitatively assessed examinations (4 indicating markedly superior to -4 indicating markedly inferior), and Hounsfield unit measurements were performed. RESULTS Enhancement (estimated mean, -0.05; 95% confidence interval [CI], -0.19 to 0.09; P = 0.46) and lesion depiction (estimated mean, -0.01; 95% CI, -0.10 to 0.07; P = 0.79) scores did not differ between CT examinations using weight-based IV contrast versus fixed IV contrast dosing when a minimum of 38.5 g of iodine was used. However, the scores using weight-based IV contrast dosing were lower when the injector software calculated and delivered less than 38.5 g of iodine (estimated mean, -0.81; 95% CI, -1.06 to -0.56; P < 0.0001). There were no significant differences in measured Hounsfield units between the CT examinations using weight-based IV contrast dosing versus fixed IV contrast dosing. CONCLUSIONS Oncologic CT image quality was maintained or improved with weight-based IV contrast dosing using injector software when using a minimum amount of 38.5 g of iodine.
Collapse
|
11
|
Zanardo M, Doniselli FM, Esseridou A, Tritella S, Mattiuz C, Menicagli L, Di Leo G, Sardanelli F. Abdominal CT: a radiologist-driven adjustment of the dose of iodinated contrast agent approaches a calculation per lean body weight. Eur Radiol Exp 2018; 2:41. [PMID: 30515613 PMCID: PMC6279751 DOI: 10.1186/s41747-018-0074-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Accepted: 10/19/2018] [Indexed: 11/10/2022] Open
Abstract
Background The contrast agent (CA) dose for abdominal computed tomography (CT) is typically based on patient total body weight (TBW), ignoring adipose tissue distribution. We report on our experience of dosing according to the lean body weight (LBW). Methods After Ethics Committee approval, we retrospectively screened 219 consecutive patients, 18 being excluded for not matching the inclusion criteria. Thus, 201 were analysed (106 males), all undergoing a contrast-enhanced abdominal CT with iopamidol (370 mgI/mL) or iomeprol (400 mgI/mL). LBW was estimated using validated formulas. Liver contrast-enhancement (CEL) was measured. Data were reported as mean ± standard deviation. Pearson correlation coefficient, ANOVA, and the Levene test were used. Results Mean age was 66 ± 13 years, TBW 72 ± 15 kg, LBW 53 ± 11 kg, and LBW/TBW ratio 74 ± 8%; body mass index was 26 ± 5 kg/m2, with 9 underweight patients (4%), 82 normal weight (41%), 76 overweight (38%), and 34 obese (17%). The administered CA dose was 0.46 ± 0.06 gI/kg of TBW, corresponding to 0.63 ± 0.09 gI/kg of LBW. A negative correlation was found between TBW and CA dose (r = -0.683, p < 0.001). CEL (Hounsfield units) was 51 ± 18 in underweight patients, 44 ± 8 in normal weight, 42 ± 9 in overweight, and 40 ± 6 in obese, with a significant difference for both mean (p = 0.004) and variance (p < 0.001). A low but significant positive correlation was found between CEL and CA dose in gI per TBW (r = 0.371, p < 0.001) or per LBW (r = 0.333, p < 0.001). Conclusions The injected CA dose was highly variable, with obese patients receiving a lower dose than underweight patients, as a radiologist-driven ‘compensation effect’. Diagnostic abdomen CT examinations may be obtained using 0.63 gI/kg of LBW.
Collapse
Affiliation(s)
- Moreno Zanardo
- PhD Course in Integrative Biomedical Research, Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milan, Italy.
| | - Fabio Martino Doniselli
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Anastassia Esseridou
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Stefania Tritella
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Chiara Mattiuz
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Laura Menicagli
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Giovanni Di Leo
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy
| | - Francesco Sardanelli
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Italy.,Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Morandi 30, 20097, San Donato Milanese, Italy
| |
Collapse
|
12
|
Eddy K, Costa AF. Assessment of Cirrhotic Liver Enhancement With Multiphasic Computed Tomography Using a Faster Injection Rate, Late Arterial Phase, and Weight-Based Contrast Dosing. Can Assoc Radiol J 2017; 68:371-378. [PMID: 28720415 DOI: 10.1016/j.carj.2017.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 12/11/2016] [Accepted: 01/03/2017] [Indexed: 01/31/2023] Open
Abstract
PURPOSE This study aimed to update our liver computed tomography (CT) protocol according to published guidelines, and to quantitatively evaluate the effect of these modifications. METHODS The modified liver CT protocol employed a faster injection rate (5 vs 3 mL/s), later arterial phase (20-second vs 10-second postbolus trigger), and weight-based dosing of iodinated contrast (1.7 mL/kg vs 100 mL fixed dose). Liver and vascular attenuation values were measured on CTs of patients with cirrhosis from January to September 2015 (old protocol, n = 49) and from October to December 2015 (modified protocol, n = 31). CTs were considered adequate if liver enhancement exceeded 50 Hounsfield units (HU) in portal venous phase, or when the unenhanced phase was unavailable, if a minimum iodine concentration of 500 mg I/kg was achieved. Attenuations and iodine concentrations were compared using the t test and the number of suboptimal studies was compared with Fisher's exact test. RESULTS CTs acquired with the modified protocol demonstrated higher aortic (P = .001) and portal vein (P < .0001) attenuations in the arterial phase as well as greater hepatic attenuation on all postcontrast phases (P = .0006, .002, and .003 for arterial, venous, and equilibrium phases, respectively). Hepatic enhancement in the portal venous phase (61 ± 15 HU vs 51 ± 16 HU; P = .0282) and iodine concentrations (595 ± 88 mg I/kg vs 456 ± 112 mg I/kg; P < .0001) were improved, and the number of suboptimal studies was reduced from 57% to 23% (P = .01). CONCLUSIONS A liver CT protocol with later arterial phase, faster injection rate, and weight-based dosing of intravenous contrast significantly improves liver enhancement and iodine concentrations in patients with cirrhosis, resulting in significantly fewer suboptimal studies.
Collapse
Affiliation(s)
- Kathleen Eddy
- Department of Diagnostic Radiology, QE II Health Sciences Centre, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Andreu F Costa
- Department of Diagnostic Radiology, QE II Health Sciences Centre, Dalhousie University, Halifax, Nova Scotia, Canada.
| |
Collapse
|
13
|
Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output. J Comput Assist Tomogr 2017; 41:309-314. [PMID: 27759599 DOI: 10.1097/rct.0000000000000513] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning. METHODS This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement. RESULTS Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P < 0.001). However, multivariate linear regression analysis showed that only the TBW and CO were of independent predictive value (P < 0.001). Also, only the CO was independently and negatively related to aortic enhancement during HAP and to liver parenchymal enhancement when the contrast material injection protocol was adjusted for the TBW (P < 0.001). CONCLUSION By multivariate linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.
Collapse
|
14
|
Davenport MS, Parikh KR, Mayo-Smith WW, Israel GM, Brown RK, Ellis JH. Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT. J Am Coll Radiol 2017; 14:359-370. [DOI: 10.1016/j.jacr.2016.09.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 07/29/2016] [Accepted: 09/01/2016] [Indexed: 11/16/2022]
|
15
|
Comparison between a fixed-dose contrast protocol and a weight-based contrast dosing protocol in abdominal CT. Clin Radiol 2016; 71:1314.e1-1314.e9. [DOI: 10.1016/j.crad.2016.07.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2016] [Revised: 07/12/2016] [Accepted: 07/14/2016] [Indexed: 11/23/2022]
|
16
|
Svensson A, Cederlund K, Aspelin P, Nyman U, Brismar TB. The effect of arm positioning on timing and enhancement of intravenous contrast media at coronary computed tomography angiography. Acta Radiol 2016; 57:1049-55. [PMID: 26567961 DOI: 10.1177/0284185115615004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 10/09/2015] [Indexed: 12/27/2022]
Abstract
BACKGROUND Adequate intravenous contrast media (CM) enhancement is crucial for evaluation of the coronary arteries. PURPOSE To compare the timing and enhancement of intravenous CM at coronary computed tomography angiography (CCTA) when positioning the arms in the traditional superior direction with that of positioning them in the ventral direction during the CM injection. MATERIAL AND METHODS One hundred patients were randomized into two groups. Group A (n = 50) had their arms positioned in the superior direction, resting on a head and arm support. Group B (n = 50) held their arms resting on the front panel of the computer tomography (CT) scanner. Scanning delay time was defined by test bolus technique. A total of 60 mL iodixanol, 320 mg/mL, was followed by a 50 mL saline flush at 6 mL/s. Cardiac output (CO) and heart rate (HR) were obtained before scanning. The attenuation was calculated by placing regions of interest (ROI) in ascending aorta, left atrium, and inferior vena cava. RESULTS More patients in group A compared with group B (26 versus 14) showed a higher attenuation of the left atrium in comparison to the ascending aorta (P < 0.05). Body weight (BW) and CO were significantly related to the attenuation of ascending aorta (P < 0.01). CONCLUSION By placing the arms in a ventral, instead of superior position the frequency of too early imaging at CCTA can be reduced.
Collapse
Affiliation(s)
- Anders Svensson
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, SE-14186 Stockholm, Sweden
| | - Kerstin Cederlund
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, SE-14186 Stockholm, Sweden
| | - Peter Aspelin
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, SE-14186 Stockholm, Sweden
| | - Ulf Nyman
- Department of Radiology, Institution of Clinical Sciences, Malmö, Faculty of Medicine, University of Lund, SE-221 00 Lund, Sweden
| | - Torkel B Brismar
- Department of Clinical Science, Intervention and Technology at Karolinska Institutet, Division of Medical Imaging and Technology, Stockholm, Sweden
- Department of Radiology, Karolinska University Hospital in Huddinge, SE-14186 Stockholm, Sweden
| |
Collapse
|
17
|
Awai K, Kanematsu M, Kim T, Ichikawa T, Nakamura Y, Nakamoto A, Yoshioka K, Mochizuki T, Matsunaga N, Yamashita Y. The Optimal Body Size Index with Which to Determine Iodine Dose for Hepatic Dynamic CT: A Prospective Multicenter Study. Radiology 2016; 278:773-81. [DOI: 10.1148/radiol.2015142941] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Svensson A, Björk J, Cederlund K, Aspelin P, Nyman U, Brismar TB. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI(vol)). Eur Radiol 2014; 24:1959-63. [PMID: 24859598 DOI: 10.1007/s00330-014-3220-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Revised: 04/08/2014] [Accepted: 05/06/2014] [Indexed: 11/24/2022]
Abstract
PURPOSE To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index CTDI(vol)) and body weight (BW). MATERIAL AND METHODS One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI(vol) presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. RESULTS Liver parenchymal enhancement was negatively correlated to both CTDI(vol) (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CONCLUSION CTDI(vol) may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. KEY POINTS • CTDI vol is related to liver CM enhancement in the parenchymal phase. • CTDI vol provides comparable information to body weight (BW). • CTDI vol may be used when automatically adjusting CM dose for patient size.
Collapse
Affiliation(s)
- Anders Svensson
- Department of Clinical Science, Division of Medical Imaging and Technology, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden,
| | | | | | | | | | | |
Collapse
|
19
|
Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? Eur Radiol 2013; 23:1855-61. [DOI: 10.1007/s00330-013-2808-z] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 01/21/2013] [Accepted: 02/07/2013] [Indexed: 12/17/2022]
|