1
|
Jin Q, Paunesku T, Lai B, Gleber SC, Chen SI, Finney L, Vine D, Vogt S, Woloschak G, Jacobsen C. Preserving elemental content in adherent mammalian cells for analysis by synchrotron-based x-ray fluorescence microscopy. J Microsc 2016; 265:81-93. [PMID: 27580164 PMCID: PMC5217071 DOI: 10.1111/jmi.12466] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Revised: 07/11/2016] [Accepted: 08/02/2016] [Indexed: 01/20/2023]
Abstract
Trace metals play important roles in biological function, and x-ray fluorescence microscopy (XFM) provides a way to quantitatively image their distribution within cells. The faithfulness of these measurements is dependent on proper sample preparation. Using mouse embryonic fibroblast NIH/3T3 cells as an example, we compare various approaches to the preparation of adherent mammalian cells for XFM imaging under ambient temperature. Direct side-by-side comparison shows that plunge-freezing-based cryoimmobilization provides more faithful preservation than conventional chemical fixation for most biologically important elements including P, S, Cl, K, Fe, Cu, Zn and possibly Ca in adherent mammalian cells. Although cells rinsed with fresh media had a great deal of extracellular background signal for Cl and Ca, this approach maintained cells at the best possible physiological status before rapid freezing and it does not interfere with XFM analysis of other elements. If chemical fixation has to be chosen, the combination of 3% paraformaldehyde and 1.5 % glutaraldehyde preserves S, Fe, Cu and Zn better than either fixative alone. When chemically fixed cells were subjected to a variety of dehydration processes, air drying was proved to be more suitable than other drying methods such as graded ethanol dehydration and freeze drying. This first detailed comparison for x-ray fluorescence microscopy shows how detailed quantitative conclusions can be affected by the choice of cell preparation method.
Collapse
Affiliation(s)
- Qiaoling Jin
- Department of Physics & Astronomy, Weinberg College of Arts and Sciences, Evanston, Illinois, U.S.A
| | - Tatjana Paunesku
- Department of Radiation Oncology, Northwestern University, Chicago, Illinois, U.S.A
| | - Barry Lai
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| | | | - S I Chen
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| | - Lydia Finney
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| | - David Vine
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| | - Stefan Vogt
- Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| | - Gayle Woloschak
- Department of Radiation Oncology, Northwestern University, Chicago, Illinois, U.S.A
| | - Chris Jacobsen
- Department of Physics & Astronomy, Weinberg College of Arts and Sciences, Evanston, Illinois, U.S.A.,Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois, U.S.A
| |
Collapse
|
2
|
Sun Y, Gleber SC, Jacobsen C, Kirz J, Vogt S. Optimizing detector geometry for trace element mapping by X-ray fluorescence. Ultramicroscopy 2015; 152:44-56. [PMID: 25600825 DOI: 10.1016/j.ultramic.2014.12.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Revised: 12/23/2014] [Accepted: 12/23/2014] [Indexed: 01/02/2023]
Abstract
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.
Collapse
Affiliation(s)
- Yue Sun
- Graduate Program in Applied Physics, Northwestern University, Evanston, IL 60208, USA.
| | | | - Chris Jacobsen
- Argonne National Laboratory, Argonne, IL 60439, USA; Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA; Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA.
| | - Janos Kirz
- Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| | - Stefan Vogt
- Argonne National Laboratory, Argonne, IL 60439, USA.
| |
Collapse
|
3
|
de Jonge MD, Ryan CG, Jacobsen CJ. X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:1031-47. [PMID: 25177992 PMCID: PMC4151681 DOI: 10.1107/s160057751401621x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Accepted: 07/11/2014] [Indexed: 05/22/2023]
Abstract
X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer.
Collapse
Affiliation(s)
- Martin D. de Jonge
- Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168, Australia
| | - Christopher G. Ryan
- CSIRO Earth Science and Research Engineering, Clayton, Victoria 3168, Australia
| | - Chris J. Jacobsen
- Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439, USA
- Department of Physics, Chemistry of Life Processes Institute, Northwestern University, 2170 Campus Drive, Evanston, IL 60208, USA
- Chemistry of Life Processes Institute, Northwestern University, 2170 Campus Drive, Evanston, IL 60208, USA
| |
Collapse
|
4
|
James SA, Myers DE, de Jonge MD, Vogt S, Ryan CG, Sexton BA, Hoobin P, Paterson D, Howard DL, Mayo SC, Altissimo M, Moorhead GF, Wilkins SW. Quantitative comparison of preparation methodologies for X-ray fluorescence microscopy of brain tissue. Anal Bioanal Chem 2011; 401:853-64. [PMID: 21533642 DOI: 10.1007/s00216-011-4978-3] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2011] [Revised: 03/29/2011] [Accepted: 04/02/2011] [Indexed: 11/26/2022]
Abstract
X-ray fluorescence microscopy (XFM) facilitates high-sensitivity quantitative imaging of trace metals at high spatial resolution over large sample areas and can be applied to a diverse range of biological samples. Accurate determination of elemental content from recorded spectra requires proper calibration of the XFM instrument under the relevant operating conditions. Here, we describe the manufacture, characterization, and utilization of multi-element thin-film reference foils for use in calibration of XFM measurements of biological and other specimens. We have used these internal standards to assess the two-dimensional distribution of trace metals in a thin tissue section of a rat hippocampus. The data used in this study was acquired at the XFM beamline of the Australian Synchrotron using a new 384-element array detector (Maia) and at beamline 2-ID-E at the Advanced Photon Source. Post-processing of samples by different fixation techniques was investigated, with the conclusion that differences in solvent type and sample handling can significantly alter elemental content. The present study highlights the quantitative capability, high statistical power, and versatility of the XFM technique for mapping trace metals in biological samples, e.g., brain tissue samples in order to help understand neurological processes, especially when implemented in conjunction with a high-performance detector such as Maia.
Collapse
Affiliation(s)
- Simon A James
- Materials Science and Engineering and the Preventative Health Flagship, CSIRO, Gate 5, Normanby Road (Private Bag 33, Clayton South 3169), Clayton, VIC 3168, Australia.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Stys PK, Lopachin RM. Mechanisms of calcium and sodium fluxes in anoxic myelinated central nervous system axons. Neuroscience 1998; 82:21-32. [PMID: 9483500 DOI: 10.1016/s0306-4522(97)00230-3] [Citation(s) in RCA: 95] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Electron probe X-ray microanalysis was used to measure water content and concentrations of elements (i.e. Na, K, Cl and Ca) in selected morphological compartments of rat optic nerve myelinated axons. Transaxolemmal movements of Na+ and Ca2+ were modified experimentally and corresponding effects on axon element and water compositions were determined under control conditions and following in vitro anoxic challenge. Also characterized were effects of modified ion transport on axon responses to postanoxia reoxygenation. Blockade of Na+ entry by tetrodotoxin (1 microM) or zero Na+/Li(+)-substituted perfusion reduced anoxic increases in axonal Na and Ca concentrations. Incubation with zero-Ca2+/EGTA perfusate prevented axoplasmic and mitochondrial Ca accumulation during anoxia but did not affect Na increases or K losses in these compartments. Inhibition of Na(+)-Ca2+ exchange with bepridil (30 microM) selectively prevented increases in intra-axonal Ca, whereas neither nifedipine (5 microM) nor nimodipine (5 microM) influenced the effects of anoxia on axonal Na, K or Ca. X-ray microanalysis also showed that prevention of Na and Ca influx during anoxia obtunded severe elemental deregulation normally associated with reoxygenation. Results of the present study suggest that during anoxia, Na+ enters axons mainly through voltage-gated Na+ channels and that subsequent increases in axoplasmic Na+ are functionally coupled to extra-axonal Ca2+ import. Na+i-dependent, Ca2+o entry is consistent with reverse operation of the axolemmal Na(+)-Ca2+ exchanger and we suggest this route represents a primary mechanism of Ca2+ influx. Our findings also implicate a minor route of Ca2+ entry directly through Na+ channels.
Collapse
Affiliation(s)
- P K Stys
- Loeb Research Institute, Ottawa Civic Hospital, University of Ottawa, Canada
| | | |
Collapse
|
6
|
Abstract
This review summarizes current knowledge relating intracellular calcium and glial function. During steady state, glia maintain a low cytosolic calcium level by pumping calcium into intracellular stores and by extruding calcium across the plasma membrane. Glial Ca2+ increases in response to a variety of physiological stimuli. Some stimuli open membrane calcium channels, others release calcium from intracellular stores, and some do both. The temporal and spatial complexity of glial cytosolic calcium changes suggest that these responses may form the basis of an intracellular or intercellular signaling system. Cytosolic calcium rises effect changes in glial structure and function through protein kinases, phospholipases, and direct interaction with lipid and protein constituents. Ultimately, calcium signaling influence glial gene expression, development, metabolism, and regulation of the extracellular milieu. Disturbances in glial calcium homeostasis may have a role in certain pathological conditions. The discovery of complex calcium-based glial signaling systems, capable of sensing and influencing neural activity, suggest a more integrated neuro-glial model of information processing in the central nervous system.
Collapse
Affiliation(s)
- S M Finkbeiner
- Department of Medicine, University of California, San Francisco 94143-0114
| |
Collapse
|
7
|
Lowe T, Chen Q, Fernando Q, Keith R, Gandolfi AJ. Elemental analysis of renal slices by proton-induced X-ray emission. ENVIRONMENTAL HEALTH PERSPECTIVES 1993; 101:302-8. [PMID: 8275986 PMCID: PMC1519791 DOI: 10.1289/ehp.93101302] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We optimized proton-induced X-ray emission (PIXE) for tissue analysis in a toxicity-disposition study. We used cultured rabbit renal slices as the biological system to demonstrate the use of PIXE analysis. The renal slices were exposed to HgCl2, CdCl2, K2Cr2O7, or NaAsO2 alone or in a mixture. The PIXE analysis provides information on concentrations of elements above atomic number 11, and it is the only analytical technique that can determine 20-30 elements nondestructively in a single, small sample (approximately 5 mg) with detection limits of 1-5 ppm (dry weight). The renal slices are thin targets that yield X-ray emission spectra with low backgrounds and high elemental sensitivities. The nondestructive nature of PIXE and the ability to simultaneously measure uptake of multiple metals and endogenous elements are unique to this methodology.
Collapse
Affiliation(s)
- T Lowe
- Department of Chemistry, University of Arizona, Tucson 85721
| | | | | | | | | |
Collapse
|
8
|
LeFurgey A, Davilla SD, Kopf DA, Sommer JR, Ingram P. Real-time quantitative elemental analysis and mapping: microchemical imaging in cell physiology. J Microsc 1992; 165:191-223. [PMID: 1564720 DOI: 10.1111/j.1365-2818.1992.tb01481.x] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Recent advances in widely available microcomputers have made the acquisition and processing of digital quantitative X-ray maps of one to several cells readily feasible. Here we describe a system which uses a graphics-based microcomputer to acquire spectrally filtered X-ray elemental image maps that are fitted to standards, to display the image in real time, and to correct the post-acquisition image map with regard to specimen drift. Both high-resolution quantitative energy-dispersive X-ray images of freeze-dried cyrosections and low-dose quantitative bright-field images of frozen-hydrated sections can be acquired to obtain element and water content from the same intracellular regions. The software programs developed, together with the associated hardware, also allow static probe acquisition of data from selected cell regions with spectral processing and quantification performed on-line in real time. In addition, the unified design of the software program provides for off-line processing and analysing by several investigators at microcomputers remote from the microscope. The overall experimental strategy employs computer-aided imaging, combined with static probes, as an essential interactive tool of investigation for biological analysis. This type of microchemical microscopy facilitates studies in cell physiology and pathophysiology which focus on mechanisms of ionic (elemental) compartmentation, i.e. structure-function correlation at cellular and subcellular levels; it allows investigation of intracellular concentration gradients, of the heterogeneity of cell responses to stimuli, of certain fast physiological events in vivo at ultrastructural resolution, and of events occurring with low incidence or involving cell-to-cell interactions.
Collapse
Affiliation(s)
- A LeFurgey
- Department of Cell Biology, School of Medicine, Duke University, Durham, NC 27710
| | | | | | | | | |
Collapse
|