Vincely VD, Bayer CL. Photoacoustic imaging of rat kidney tissue oxygenation using second near-infrared wavelengths. JOURNAL OF BIOMEDICAL OPTICS 2025; 30:026002. [PMID: 39968505 PMCID: PMC11833698 DOI: 10.1117/1.jbo.30.2.026002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Revised: 01/20/2025] [Accepted: 01/24/2025] [Indexed: 02/20/2025]
Abstract
Significance Conventionally, spectral photoacoustic imaging (sPAI) to assess tissue oxygenation (sO 2 ) uses optical wavelengths in the first near-infrared (NIR-I) window. This limits the maximum photoacoustic imaging depth due to the high spectral coloring of biological tissues and has been a major barrier to the clinical translation of the technique. Aim We demonstrate the second near-infrared (NIR-II) tissue optical window (950 to 1400 nm) for the assessment of blood and tissuesO 2 . Approach The NIR-II PA spectra of oxygenated and deoxygenated hemoglobin were first characterized using a phantom. Optimal wavelengths to minimize spectral coloring were identified. The resulting NIR-II PA imaging methods were then validated in vivo by measuring kidneysO 2 in adult female rats. Results sPAI of whole blood, in a phantom, and of blood in kidneys in vivo produced PA spectra proportional to wavelength-dependent optical absorption. Using the NIR-II wavelengths for spectral unmixing resulted in a ∼ 50 % decrease in the error of the estimated bloodsO 2 , compared with conventional NIR-I wavelengths. In vivo measurements of kidneysO 2 validated these findings, with a similar 50% reduction in error when using NIR-II wavelengths versus NIR-I wavelengths at larger illumination depths. Conclusions sPAI using NIR-II wavelengths improved the accuracy of tissuesO 2 measurements. This is likely due to reduced scattering, which reduces the attenuation and, therefore, the impact of spectral coloring in this wavelength range. Combined with the increased safe skin exposure fluence limits in this wavelength range, these results demonstrate the potential to use NIR-II wavelengths for quantitative sPAI ofsO 2 from deep heterogeneous tissues.
Collapse
Affiliation(s)
- Vinoin Devpaul Vincely
- Tulane University, Department of Biomedical Engineering, New Orleans, Louisiana, United States
| | - Carolyn L. Bayer
- Tulane University, Department of Biomedical Engineering, New Orleans, Louisiana, United States
| |
Collapse
|
2
|
Sudakou A, Wabnitz H, Liemert A, Wolf M, Liebert A. Two-layered blood-lipid phantom and method to determine absorption and oxygenation employing changes in moments of DTOFs. BIOMEDICAL OPTICS EXPRESS 2023; 14:3506-3531. [PMID: 37497481 PMCID: PMC10368065 DOI: 10.1364/boe.492168] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/29/2023] [Accepted: 05/29/2023] [Indexed: 07/28/2023]
Abstract
Near-infrared spectroscopy (NIRS) is an established technique for measuring tissue oxygen saturation (StO2), which is of high clinical value. For tissues that have layered structures, it is challenging but clinically relevant to obtain StO2 of the different layers, e.g. brain and scalp. For this aim, we present a new method of data analysis for time-domain NIRS (TD-NIRS) and a new two-layered blood-lipid phantom. The new analysis method enables accurate determination of even large changes of the absorption coefficient (Δµa) in multiple layers. By adding Δµa to the baseline µa, this method provides absolute µa and hence StO2 in multiple layers. The method utilizes (i) changes in statistical moments of the distributions of times of flight of photons (DTOFs), (ii) an analytical solution of the diffusion equation for an N-layered medium, (iii) and the Levenberg-Marquardt algorithm (LMA) to determine Δµa in multiple layers from the changes in moments. The method is suitable for NIRS tissue oximetry (relying on µa) as well as functional NIRS (fNIRS) applications (relying on Δµa). Experiments were conducted on a new phantom, which enabled us to simulate dynamic StO2 changes in two layers for the first time. Two separate compartments, which mimic superficial and deep layers, hold blood-lipid mixtures that can be deoxygenated (using yeast) and oxygenated (by bubbling oxygen) independently. Simultaneous NIRS measurements can be performed on the two-layered medium (variable superficial layer thickness, L), the deep (homogeneous), and/or the superficial (homogeneous). In two experiments involving ink, we increased the nominal µa in one of two compartments from 0.05 to 0.25 cm-1, L set to 14.5 mm. In three experiments involving blood (L set to 12, 15, or 17 mm), we used a protocol consisting of six deoxygenation cycles. A state-of-the-art multi-wavelength TD-NIRS system measured simultaneously on the two-layered medium, as well as on the deep compartment for a reference. The new method accurately determined µa (and hence StO2) in both compartments. The method is a significant progress in overcoming the contamination from the superficial layer, which is beneficial for NIRS and fNIRS applications, and may improve the determination of StO2 in the brain from measurements on the head. The advanced phantom may assist in the ongoing effort towards more realistic standardized performance tests in NIRS tissue oximetry. Data and MATLAB codes used in this study were made publicly available.
Collapse
Affiliation(s)
- Aleh Sudakou
- Nałęcz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Warsaw, Poland
| | - Heidrun Wabnitz
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - André Liemert
- Institut für Lasertechnologien in der Medizin und Meßtechnik an der Universität Ulm, Germany
| | - Martin Wolf
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Adam Liebert
- Nałęcz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
3
|
Eleveld N, Esquivel-Franco DC, Drost G, Absalom AR, Zeebregts CJ, de Vries JPPM, Elting JWJ, Maurits NM. The Influence of Extracerebral Tissue on Continuous Wave Near-Infrared Spectroscopy in Adults: A Systematic Review of In Vivo Studies. J Clin Med 2023; 12:jcm12082776. [PMID: 37109113 PMCID: PMC10146120 DOI: 10.3390/jcm12082776] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/04/2023] [Accepted: 04/05/2023] [Indexed: 04/29/2023] Open
Abstract
Near-infrared spectroscopy (NIRS) is a non-invasive technique for measuring regional tissue haemoglobin (Hb) concentrations and oxygen saturation (rSO2). It may be used to monitor cerebral perfusion and oxygenation in patients at risk of cerebral ischemia or hypoxia, for example, during cardiothoracic or carotid surgery. However, extracerebral tissue (mainly scalp and skull tissue) influences NIRS measurements, and the extent of this influence is not clear. Thus, before more widespread use of NIRS as an intraoperative monitoring modality is warranted, this issue needs to be better understood. We therefore conducted a systematic review of published in vivo studies of the influence of extracerebral tissue on NIRS measurements in the adult population. Studies that used reference techniques for the perfusion of the intra- and extracerebral tissues or that selectively altered the intra- or extracerebral perfusion were included. Thirty-four articles met the inclusion criteria and were of sufficient quality. In 14 articles, Hb concentrations were compared directly with measurements from reference techniques, using correlation coefficients. When the intracerebral perfusion was altered, the correlations between Hb concentrations and intracerebral reference technique measurements ranged between |r| = 0.45-0.88. When the extracerebral perfusion was altered, correlations between Hb concentrations and extracerebral reference technique measurements ranged between |r| = 0.22-0.93. In studies without selective perfusion modification, correlations of Hb with intra- and extracerebral reference technique measurements were generally lower (|r| < 0.52). Five articles studied rSO2. There were varying correlations of rSO2 with both intra- and extracerebral reference technique measurements (intracerebral: |r| = 0.18-0.77, extracerebral: |r| = 0.13-0.81). Regarding study quality, details on the domains, participant selection and flow and timing were often unclear. We conclude that extracerebral tissue indeed influences NIRS measurements, although the evidence (i.e., correlation) for this influence varies considerably across the assessed studies. These results are strongly affected by the study protocols and analysis techniques used. Studies employing multiple protocols and reference techniques for both intra- and extracerebral tissues are therefore needed. To quantitatively compare NIRS with intra- and extracerebral reference techniques, we recommend applying a complete regression analysis. The current uncertainty regarding the influence of extracerebral tissue remains a hurdle in the clinical implementation of NIRS for intraoperative monitoring. The protocol was pre-registered in PROSPERO (CRD42020199053).
Collapse
Affiliation(s)
- Nick Eleveld
- Department of Neurology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Diana C Esquivel-Franco
- Department of Neurology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Gea Drost
- Department of Neurology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
- Department of Neurosurgery, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Anthony R Absalom
- Department of Anaesthesiology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Clark J Zeebregts
- Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Jean-Paul P M de Vries
- Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Jan Willem J Elting
- Department of Neurology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| | - Natasha M Maurits
- Department of Neurology, University Medical Centre Groningen, University of Groningen, Postbus 30001, 9700 RB Groningen, The Netherlands
| |
Collapse
|
4
|
Zhao M, Zhou M, Cao X, Feng J, Pogue BW, Paulsen KD, Jiang S. Stable tissue-mimicking phantoms for longitudinal multimodality imaging studies that incorporate optical, CT, and MRI contrast. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:046006. [PMID: 37091909 PMCID: PMC10118137 DOI: 10.1117/1.jbo.28.4.046006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 03/30/2023] [Indexed: 05/03/2023]
Abstract
Significance Tissue phantoms that mimic the optical and radiologic properties of human or animal tissue play an important role in the development, characterization, and evaluation of imaging systems. Phantoms that are easily produced and stable for longitudinal studies are highly desirable. Aim A new type of long-lasting phantom was developed with commercially available materials and was assessed for fabrication ease, stability, and optical property control. Magnetic resonance imaging (MRI) and x-ray computed tomography (CT) contrast properties were also evaluated. Approach A systematic investigation of relationships between concentrations of skin-like pigments and composite optical properties was conducted to realize optical property phantoms in the red and near-infrared (NIR) wavelength range that also offered contrast for CT and MRI. Results Phantom fabrication time was < 1 h and did not involve any heating or cooling processes. Changes in optical properties were < 2 % over a 12-month period. Phantom optical and spectral features were similar to human soft tissue over the red to NIR wavelength ranges. Pigments used in the study also had CT and MRI contrasts for multimodality imaging studies. Conclusions The phantoms described here mimic optical properties of soft tissue and are suitable for multimodality imaging studies involving CT or MRI without adding secondary contrast agents.
Collapse
Affiliation(s)
- Mengyang Zhao
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Mingwei Zhou
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Xu Cao
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Jinchao Feng
- Beijing University of Technology, Beijing Key Laboratory of Computational Intelligence and Intelligent System, Faculty of Information Technology, Beijing, China
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Keith D. Paulsen
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Shudong Jiang
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| |
Collapse
|
5
|
Roldan M, Kyriacou PA. Head Phantom Optical Properties Validation for Near-Infrared Measurements: A Comparison with Animal Tissue. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:641-644. [PMID: 36085774 DOI: 10.1109/embc48229.2022.9871103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The interest in optical healthcare technologies has increased significantly over the recent years. The innovation of new optical technologies such as Near Infrared Spectroscopy (NIRS), used for the monitoring of brain perfusion, demands a comprehensive understanding and knowledge of the light tissue interaction. Phantoms can provide a rigorous, reproducible and convenient approach for evaluating an optical sensor's performance. However, up to date literature does not provide a detailed description of a complete head model that involves the human anatomy, physiological changes, and the tissue optical properties. The latter is key for the design, development and testing of optical sensors, such as NIRS technologies. This paper compared the optical properties of the materials chosen to build a head phantom, against the optical properties of real brain and skull tissues extracted from animal models. The spectra of a silicone brain and resin skull samples were compared with the spectra of the respective tissues extracted from pigs and mice. The results of this study demonstrated that both phantom materials have similar optical properties to mice and pigs' tissues. The morphology of the phantom's spectra were very similar to the respective animal tissue comparator.
Collapse
|
6
|
Combined Non-Invasive Optical Oximeter and Flowmeter with Basic Metrological Equipment. PHOTONICS 2022. [DOI: 10.3390/photonics9060392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Optical non-invasive diagnostic methods and equipment are used today in many medical disciplines. However, there is still no generally accepted and unifying engineering theory of such systems. Today, they are developed most empirically and do not always have the desired effectiveness in clinics. Among reasons for their insufficient clinical efficiency, we can claim the limited set of measured parameters, the poorly substantiated technical design parameters, and the lack of metrological certification, which all together lead to large uncertainties and inaccuracies in diagnostic data. The purpose of this study is to develop a new instrument for non-invasive optical oximetry by means of substantiating and creating amore informative tissue oximeter with an enhanced number of measured parameters and equipped with the basic metrological tools—imitational measures. The combination of two related optical diagnostic techniques—a tissue oximetry, including a cerebral one, and a fluctuation flowmetry on a single hardware platform—was used. Theoretical modeling of light transport in tissues was applied to substantiate the main technical design parameters of the device. For each measuring channel, relevant imitation measures for metrological verification and adjustment have been proposed. Some common principles for the operation of such equipment are described in the article, as well.
Collapse
|
7
|
Afshari A, Saager RB, Burgos D, Vogt WC, Wang J, Mendoza G, Weininger S, Sung KB, Durkin AJ, Pfefer TJ. Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom. BIOMEDICAL OPTICS EXPRESS 2022; 13:2909-2928. [PMID: 35774336 PMCID: PMC9203096 DOI: 10.1364/boe.454020] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 03/14/2022] [Accepted: 03/28/2022] [Indexed: 05/20/2023]
Abstract
Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances. Referenced blood oxygenation levels ranged from 30 to 90%. Cerebral oximeter outputs exhibited a consistent decrease in saturation level with simulated melanin content; this effect was greatest at low saturation levels, producing a change of up to 15%. Dependence on pigmentation was strongest in a neonatal sensor, possibly due to its high reflectivity. Overall, our findings indicate that a modular channel-array phantom approach can provide a practical tool for assessing the impact of skin pigmentation on cerebral oximeter performance and that modifications to algorithms and/or instrumentation may be needed to mitigate pigmentation bias.
Collapse
Affiliation(s)
- Ali Afshari
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Rolf B. Saager
- Linköping Univ., Dept. of Biomedical Engineering, Linköping, Sweden
| | - David Burgos
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - William C. Vogt
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Jianting Wang
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Gonzalo Mendoza
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Sandy Weininger
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Kung-Bin Sung
- National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei, Taiwan
| | - Anthony J. Durkin
- Department of Biomedical Engineering, University of California, Irvine, 3120 Natural Sciences II, Irvine, California 92697, USA
- Beckman Laser Institute & Medical Clinic, University of California, Irvine, 1002 Health Sciences Rd. East Irvine, California 92617, USA
| | - T. Joshua Pfefer
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| |
Collapse
|
8
|
Hacker L, Wabnitz H, Pifferi A, Pfefer TJ, Pogue BW, Bohndiek SE. Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation. Nat Biomed Eng 2022; 6:541-558. [PMID: 35624150 DOI: 10.1038/s41551-022-00890-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 02/07/2022] [Indexed: 01/08/2023]
Abstract
A lack of accepted standards and standardized phantoms suitable for the technical validation of biophotonic instrumentation hinders the reliability and reproducibility of its experimental outputs. In this Perspective, we discuss general criteria for the design of tissue-mimicking biophotonic phantoms, and use these criteria and state-of-the-art developments to critically review the literature on phantom materials and on the fabrication of phantoms. By focusing on representative examples of standardization in diffuse optical imaging and spectroscopy, fluorescence-guided surgery and photoacoustic imaging, we identify unmet needs in the development of phantoms and a set of criteria (leveraging characterization, collaboration, communication and commitment) for the standardization of biophotonic instrumentation.
Collapse
Affiliation(s)
- Lina Hacker
- Department of Physics, University of Cambridge, Cambridge, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
| | - Heidrun Wabnitz
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | | | | | - Brian W Pogue
- Thayer School of Engineering, Dartmouth, Hanover, NH, USA
| | - Sarah E Bohndiek
- Department of Physics, University of Cambridge, Cambridge, UK.
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK.
| |
Collapse
|
9
|
Fales AM, Strobbia P, Vo-Dinh T, Ilev IK, Pfefer TJ. 3D-printed phantoms for characterizing SERS nanoparticle detectability in turbid media. Analyst 2021; 145:6045-6053. [PMID: 32766656 DOI: 10.1039/d0an01295e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Recent advances in plasmonic nanoparticle synthesis have enabled extremely high per-particle surface-enhanced Raman scattering (SERS) efficiencies. This has led to the development of SERS tags for in vivo applications (e.g. tumor targeting and detection), providing high sensitivity and fingerprint-like molecular specificity. While the SERS enhancement factor is a major contributor to SERS tag performance, in practice the throughput and excitation-collection geometry of the optical system can significantly impact detectability. Test methods to objectively quantify SERS particle performance under realistic conditions are necessary to facilitate clinical translation. Towards this goal, we have developed 3D-printed phantoms with tunable, biologically-relevant optical properties. Phantoms were designed to include 1 mm-diameter channels at different depths, which can be filled with SERS tag solutions. The effects of channel depth and particle concentration on the detectability of three different SERS tags were evaluated using 785 nm laser excitation at the maximum permissible exposure for skin. Two of these tags were commercially available, featuring gold nanorods as the SERS particle, while the third tag was prepared in-house using silver-coated gold nanostars. Our findings revealed that the measured SERS intensity of tags in solution is not always a reliable predictor of detectability when applied in a turbid medium such as tissue. The phantoms developed in this work can be used to assess the suitability of specific SERS tags and instruments for their intended clinical applications and provide a means of optimizing new SERS device-tag combination products.
Collapse
Affiliation(s)
- Andrew M Fales
- Division of Biomedical Physics, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, USA.
| | | | | | | | | |
Collapse
|