di Franco F, Baudier T, Gassa F, Munoz A, Martinon M, Charcosset S, Vigier-Lafosse E, Pommier P, Sarrut D, Biston MC. Minimum non-isotropic and asymmetric margins for taking into account intrafraction prostate motion during moderately hypofractionated radiotherapy. Phys Med 2022; 96:114-120. [PMID: 35278928 DOI: 10.1016/j.ejmp.2022.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 03/04/2022] [Accepted: 03/04/2022] [Indexed: 12/11/2022] Open
Abstract
PURPOSE To investigate the impact on dose distribution of intrafraction motion during moderate hypofractionated prostate cancer treatments and to estimate minimum non-isotropic and asymmetric (NI-AS) treatment margins taking motion into account. METHODS Prostate intrafraction 3D displacements were recorded with a transperineal ultrasound probe and were evaluated in 46 prostate cancer patients (876 fractions) treated by moderate hypofractionated radiation therapy (60 Gy in 20 fractions). For 18 patients (346 fractions), treatment plans were recomputed increasing CTV-to-PTV margins from 0 to 6 mm with an auto-planning optimization algorithm. Dose distribution was estimated using the voxel shifting method by displacing CTV structure according to the retrieved movements. Time-dependent margins were finally calculated using both van Herk's formula and the voxel shifting method. RESULTS Mean intrafraction prostate displacements observed were -0.02 ± 0.52 mm, 0.27 ± 0.78 mm and -0.43 ± 1.06 mm in left-right, supero-inferior and antero-posterior directions, respectively. The CTV dosimetric coverage increased with increased CTV-to-PTV margins but it decreased with time. Hence using van Herk's formula, after 7 min of treatment, a margin of 0.4 and 0.5 mm was needed in left and right, 1.5 and 0.7 mm in inferior and superior and 1.1 and 3.2 mm in anterior and posterior directions, respectively. Conversely, using the voxel shifting method, a margin of 0 mm was needed in left-right, 2 mm in superior, 3 mm in inferior and anterior and 5 mm in posterior directions, respectively. With this latter NI-AS margin strategy, the dosimetric target coverage was equivalent to the one obtained with a 5 mm homogeneous margin. CONCLUSIONS NI-AS margins would be required to optimally take into account intrafraction motion.
Collapse
Affiliation(s)
- Francesca di Franco
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France; CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| | - Thomas Baudier
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France; CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| | - Frédéric Gassa
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France
| | - Alexandre Munoz
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France
| | | | | | | | - Pascal Pommier
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France
| | - David Sarrut
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France; CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France
| | - Marie-Claude Biston
- Centre Léon Bérard, 28 rue Laennec 69373, LYON Cedex 08, France; CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France.
| |
Collapse
|
2
|
Yock AD, Knutson A, Osmundson E. Application of an automatic, uncertainty model-guided, target-generating algorithm to lung stereotactic body radiotherapy. Med Phys 2021; 48:7623-7631. [PMID: 34726271 DOI: 10.1002/mp.15323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 10/08/2021] [Accepted: 10/19/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE This work evaluated a new radiotherapy target-generating framework (the αTarget algorithm) for creating internal target volumes for lung SBRT. METHODS Nineteen patients previously treated with definitive intent SBRT to the lung were identified from a clinical database. For each patient's 4DCT simulation scan, deformable image registration was used between phases of the scan in order to generate voxelized models of motion for 35 individual gross tumor volumes. These motion models were then used with a new implementation of a previously described target-generating algorithm to create new internal target volumes (αITVs). The resulting αITVs were analyzed with respect to their volume and the coverage they provided each tumor voxel per that voxel's motion model. The clinically used ITVs were similarly analyzed, and were then compared to the αITVs using paired Student's t-tests. In addition, isotropic margins were added to the αITVs in order to determine the largest margin magnitude that could be added without exceeding the volume of the clinical ITVs. RESULTS The αITVs increased the target coverage provided to each tumor's 5th-percentile-most-covered-voxel an average of 50.3% compared to the clinical ITVs (p < 0.0001). At the same time, the αITVs had volumes that were, on average, 31.4% smaller (p < 0.0001). The differences in volume were large enough that, on average, an extra 2 mm isotropic margin could be added to the αITV before it had a volume greater than the clinical ITV. CONCLUSIONS The αTarget algorithm can generate more effective lung SBRT internal target volumes that provide greater coverage with smaller volumes. In combination with numerous other advantages of the framework, this effectiveness makes the αTarget algorithm a powerful new method for advanced IGRT or adaptive radiotherapy techniques.
Collapse
Affiliation(s)
- Adam D Yock
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Ashley Knutson
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Evan Osmundson
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
3
|
Varnava M, Sumida I, Oda M, Kurosu K, Isohashi F, Seo Y, Otani K, Ogawa K. Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation. JOURNAL OF RADIATION RESEARCH 2021; 62:309-318. [PMID: 33341880 PMCID: PMC7948894 DOI: 10.1093/jrr/rraa123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 09/24/2020] [Accepted: 09/30/2020] [Indexed: 06/12/2023]
Abstract
The purpose of this study was to compare single-arc (SA) and double-arc (DA) treatment plans, which are planning techniques often used in prostate cancer volumetric modulated arc therapy (VMAT), in the presence of intrafractional deformation (ID) to determine which technique is superior in terms of target dose coverage and sparing of the organs at risk (OARs). SA and DA plans were created for 27 patients with localized prostate cancer. ID was introduced to the clinical target volume (CTV), rectum and bladder to obtain blurred dose distributions using an in-house software. ID was based on the motion probability function of each structure voxel and the intrafractional motion of the respective organs. From the resultant blurred dose distributions of SA and DA plans, various parameters, including the tumor control probability, normal tissue complication probability, homogeneity index, conformity index, modulation complexity score for VMAT, dose-volume indices and monitor units (MUs), were evaluated to compare the two techniques. Statistical analysis showed that most CTV and rectum parameters were significantly larger for SA plans than for DA plans (P < 0.05). Furthermore, SA plans had fewer MUs and were less complex (P < 0.05). The significant differences observed had no clinical significance, indicating that both plans are comparable in terms of target and OAR dosimetry when ID is considered. The use of SA plans is recommended for prostate cancer VMAT because they can be delivered in shorter treatment times than DA plans, and therefore benefit the patients.
Collapse
Affiliation(s)
- Maria Varnava
- Corresponding author. Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan. Tel: +81-6-6879-3482; Fax: +81-6-6879-3489;
| | - Iori Sumida
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Michio Oda
- Department of Medical Technology, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keita Kurosu
- Department of Medical Technology, Osaka University Hospital, 2-15 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Fumiaki Isohashi
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yuji Seo
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keisuke Otani
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 (D10) Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
4
|
Yock AD. Generating amorphous target margins in radiation therapy to promote maximal target coverage with minimal target size. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 166:1-8. [PMID: 30415709 DOI: 10.1016/j.cmpb.2018.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 08/09/2018] [Accepted: 09/04/2018] [Indexed: 06/09/2023]
Abstract
BACKGROUND AND SIGNIFICANCE This work provides proof-of-principle for two versions of a heuristic approach that automatically creates amorphous radiation therapy planning target volume (PTV) margins considering local effects of tumor shape and motion to ensure adequate voxel coverage with while striving to minimize PTV size. The resulting target thereby promotes disease control while minimizing the risk of normal tissue toxicity. METHODS This work describes the mixed-PDF algorithm and the independent-PDF algorithm which generate amorphous margins around a radiation therapy target by incorporating user-defined models of target motion. Both algorithms were applied to example targets - one circular and one "cashew-shaped." Target motion was modeled by four probability density functions applied to the target quadrants. The spatially variant motion model illustrates the application of the algorithms even with tissue deformation. Performance of the margins was evaluated in silico with respect to voxelized target coverage and PTV size, and was compared to conventional techniques: a threshold-based probabilistic technique and an (an)isotropic expansion technique. To demonstrate the algorithm's clinical utility, a lung cancer patient was analyzed retrospectively. For this case, 4D CT measurements were combined with setup uncertainty to compare the PTV from the mixed-PDF algorithm with a PTV equivalent to the one used clinically. RESULTS For both targets, the mixed-PDF algorithm performed best, followed by the independent-PDF algorithm, the threshold algorithm, and lastly, the (an)isotropic algorithm. Superior coverage was always achieved by the amorphous margin algorithms for a given PTV size. Alternatively, the margin required for a particular level of coverage was always smaller (8-15%) when created with the amorphous algorithms. For the lung cancer patient, the mixed-PDF algorithm resulted in a PTV that was 13% smaller than the clinical PTV while still achieving ≥99.9% coverage. CONCLUSIONS The amorphous margin algorithms are better suited for the local effects of target shape and positional uncertainties than conventional margins. As a result, they provide superior target coverage with smaller PTVs, ensuring dose delivered to the target while decreasing the risk of normal tissue toxicity.
Collapse
Affiliation(s)
- Adam D Yock
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, TN 37232, USA.
| |
Collapse
|
5
|
Kim JH, Nguyen DT, Booth JT, Huang CY, Fuangrod T, Poulsen P, O'Brien R, Caillet V, Eade T, Kneebone A, Keall P. The accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments. Radiother Oncol 2018; 126:236-243. [PMID: 29471970 DOI: 10.1016/j.radonc.2017.10.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Revised: 10/17/2017] [Accepted: 10/22/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND AND PURPOSE To perform a quantitative analysis of the accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom (6DoF) prostate motion measurements during treatments. MATERIAL AND METHODS Real-time 6DoF prostate motion was acquired using KIM for 14 prostate cancer patients (377 fractions). KIM outputs the 6DoF prostate motion, combining 3D translation and 3D rotational motion information relative to its planning position. The corresponding groundtruth target motion was obtained post-treatment based on kV/MV triangulation. The accuracy and precision of the 6DoF KIM motion estimates were calculated as the mean and standard deviation differences compared with the ground-truth. RESULTS The accuracy ± precision of real-time 6DoF KIM-measured prostate motion were 0.2 ± 1.3° for rotations and 0.1 ± 0.5 mm for translations, respectively. The magnitude of KIM-measured motion was well-correlated with the magnitude of ground-truth motion resulting in Pearson correlation coefficients of ≥0.88 in all DoF. CONCLUSIONS The results demonstrate that KIM is capable of providing the real-time 6DoF prostate target motion during patient treatments with an accuracy ± precision of within 0.2 ± 1.3° and 0.1 ± 0.5 mm for rotation and translation, respectively. As KIM only requires a single X-ray imager, which is available on most modern cancer radiotherapy devices, there is potential for widespread adoption of this technology.
Collapse
Affiliation(s)
- Jung-Ha Kim
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia
| | - Doan T Nguyen
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia
| | - Jeremy T Booth
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Australia; School of Physics, The University of Sydney, Australia
| | - Chen-Yu Huang
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia
| | - Todsaporn Fuangrod
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, Australia
| | - Per Poulsen
- Department of Oncology, Aarhus University Hospital, Denmark
| | - Ricky O'Brien
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia
| | - Vincent Caillet
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia; Northern Sydney Cancer Centre, Royal North Shore Hospital, Australia
| | - Thomas Eade
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Australia
| | - Andrew Kneebone
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Australia
| | - Paul Keall
- Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Australia.
| |
Collapse
|