1
|
La Rosa GRM, Scapellato S, Cicciù M, Pedullà E. Antimicrobial Activity of Antibacterial Sutures in Oral Surgery: A Scoping Review. Int Dent J 2024; 74:688-695. [PMID: 38429145 PMCID: PMC11287137 DOI: 10.1016/j.identj.2024.01.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 01/24/2024] [Accepted: 01/28/2024] [Indexed: 03/03/2024] Open
Abstract
OBJECTIVE The aim of this scoping review was to explore and synthesise the current evidence on the antimicrobial activity of antibacterial suture materials used in oral surgery. METHODS The review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews. A bibliographic search was carried out in the PubMed and Scopus databases to retrieve all human clinical studies that investigated the antimicrobial efficacy of antibacterial-coated sutures used in oral surgery. Included studies were screened and extracted independently by 2 examiners. Data were tabulated and qualitatively described. RESULTS The search initially returned 150 articles and resulted in 5 included studies after the duplicates' removal and the full-text screening. Selected studies were published from 2014 to 2019. Three studies (60%) were randomised clinical trials, whilst the remaining studies did not report information on randomisation. The antimicrobial agents for coated sutures included triclosan and chlorhexidine. In almost all the studies, antibacterial-coated sutures exhibited lower bacterial retention compared to those without coating. CONCLUSIONS Within limitations, the antimicrobial-coated sutures employed in oral surgery exhibited good results in terms of their microbicidal activity when compared with sutures that were not coated. Considering the high variability and confounding factors identified in the included studies, more high-quality research is needed to confirm these results. Antimicrobial-coated sutures could represent a promising and clinically valid strategy to reduce microbial colonisation in oral surgery. The reduced bacterial adherence is likely to improve the clinical success of the surgical procedures. Yet, the cost-benefit ratio of antimicrobial-coated sutures should be assessed in larger clinical trials to confirm their efficacy over conventional noncoated sutures.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Simone Scapellato
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Marco Cicciù
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
2
|
Lee DH, Choi Y, Lee MH, Park JC. Comparison of tissue response and lifting effect induced by non-absorbable elastic thread and commercialized threads in rat model. Regen Biomater 2024; 11:rbae069. [PMID: 39055305 PMCID: PMC11272176 DOI: 10.1093/rb/rbae069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Revised: 05/16/2024] [Accepted: 06/02/2024] [Indexed: 07/27/2024] Open
Abstract
As we age, our skin loses elasticity and wrinkles form. To prevent this, most people try to improve skin wrinkles by performing procedures such as fillers, and absorbable lifting threads. Another way to solve this structural problem is to use an elastic thread. Although elastic sutures made of polymer materials (such as silicone) are widely used, data regarding their properties and potential effectiveness are lacking. This study aimed to investigate the effects of inserting non-absorbable elastic threads, with different manufacturing requirements and methods, on the skin and subcutaneous tissue. In this study, non-absorbable elastic threads ELATENS and Elasticum using different manufacturing methods were compared. Each thread was transplanted into the subcutaneous layer of the back of a rat to induce wrinkles. After inducing wrinkles in the skin of rat, the degree of skin maintenance by each thread and the thickness of the capsule formed around the suture were measured. Through ex-vivo experiments on each thread, the fixation force in the tissue was confirmed. In a comparison of inflammatory response and collagen formation through histological analysis, it was confirmed that there was no significant difference from the equivalent comparative product. In conclusion, the degree of encapsulation between tissues and collagen fiber formation for improving skin wrinkles was superior in elastic threads compared to non-elastic threads. It is believed that this provides certain elasticity to the skin layer and can induce cell influx to improve wrinkles.
Collapse
Affiliation(s)
- Dae Hyung Lee
- Advanced Medical Device R&D Center, HansBiomed Co., Ltd, Seoul 05836, Republic of Korea
- Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
| | - Yeji Choi
- Advanced Medical Device R&D Center, HansBiomed Co., Ltd, Seoul 05836, Republic of Korea
| | - Mi Hee Lee
- Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
| | - Jong-Chul Park
- Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
| |
Collapse
|
3
|
Deo JK, Mehra P, Sharma R, Rehan HS. Does Unidirectional Polyglycolide Caprolactone Barbed Suture Have Improved Outcomes Over Non-barbed Suture When Applied for Intra-oral Incision Closure? J Maxillofac Oral Surg 2024; 23:81-87. [PMID: 38312973 PMCID: PMC10830978 DOI: 10.1007/s12663-023-02000-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 08/08/2023] [Indexed: 02/06/2024] Open
Abstract
Purpose The choice of wound closure material may influence the clinical outcomes of intra-oral incision closure. Studies evaluating the application of barbed suture in the oral cavity are scarce. Hence, the present study was carried out with the aim to monitor and compare the efficacy and ease of handling of monofilament polyglycolide caprolactone (PGCL) unidirectional barbed and non-barbed sutures used for intra-oral incision closure in patients undergoing transalveolar extraction of impacted mandibular third molar and mandible fracture open reduction internal fixation. Methods A prospective randomized open label study was carried out among subjects requiring intra-oral incision closure following mandibular third molar extraction and isolated mandible fracture fixation. The difficulty index of the impacted third molars was evaluated pre-operatively. Subjects were randomized to receive either 3-0 monofilament PGCL unidirectional barbed or non-barbed sutures. Incision closure time and ease of suture handling were recorded intra-operatively. Post-operatively, patients were monitored for incision healing using the Hollander wound evaluation scale (HWES) and intensity of pain using visual analog scale (VAS) on post-operative days 1, 3 and 7. Data analysis involved descriptive statistics, Chi-square, unpaired t test and multivariate analysis using the IBM SPSS-PC software (v.25.0). Results A total of 60 subjects completed the study protocol, who were randomized into two groups (n1 = n2 = 30), comparable in terms of age, gender and treatment (TAE = 51; ORIF = 9) received. The incision healing outcomes were significantly better (p = 0.016) with barbed suture using HWES on day 7. The mean closure time using barbed suture (142.50 ± 34.803 secs) was significantly (p = 0.001) shorter than that with non-barbed suture (204.56 ± 52.94 secs). The mean VAS for the barbed suture (0.97 ± 1.89) was less (p = 0.015, 95% CI) than the non-barbed suture (2.50 ± 2.91) on day 3. The suture handling ease was comparable between the two groups. Conclusion Monofilament unidirectional PGCL barbed suture has merits over the non-barbed suture with regards to superior post-operative incision healing, reduced incision closure time (43%), lower post-operative pain and comparable ease of suture handling. Hence, knotless PGCL suture is a promising alternative for intra-oral surgical incision closure in oral and maxillofacial surgery.
Collapse
Affiliation(s)
| | - Pravesh Mehra
- Lady Hardinge Medical College, New Delhi, Delhi India
| | - Rakesh Sharma
- Lady Hardinge Medical College, New Delhi, Delhi India
| | | |
Collapse
|
4
|
Patient Safety and Quality Improvement Initiatives in Cleft Lip and Palate Surgery: A Systematic Review. J Craniofac Surg 2022; 34:979-986. [PMID: 36730883 DOI: 10.1097/scs.0000000000009094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 09/04/2022] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Cleft lip and/or palate repair techniques require continued reevaluation of best practice through high-quality evidence. The objective of this systematic review was to highlight the existing evidence for patient safety and quality improvement (QI) initiatives in cleft lip and palate surgery. METHODS A systematic review of published literature evaluating patient safety and QI in patients with cleft lip and/or palate was conducted from database inception to June 9, 2022, using Preferred Reporting Items for Systematic Reviews guidelines. Quality appraisal of included studies was conducted using Methodological Index for Non-Randomized Studies, Cochrane, or a Measurement Tool to Assess Systematic Reviews (AMSTAR) 2 instruments, according to study type. RESULTS Sixty-one studies met inclusion criteria, with most published between 2010 and 2020 (63.9%). Randomized controlled trials represented the most common study design (37.7%). Half of all included studies were related to the topic of pain and analgesia, with many supporting the use of infraorbital nerve block using 0.25% bupivacaine. The second most common intervention examined was use of perioperative antibiotics in reducing fistula and infection (11.5%). Other studies examined optimal age and closure material for cleft lip repair, early recovery after surgery protocols, interventions to reduce blood loss, and safety of outpatient surgery. CONCLUSIONS Patient safety and QI studies in cleft surgery were of moderate quality overall and covered a wide range of interventions. To further enhance PS in cleft repair, more high-quality research in the areas of perioperative pharmaceutical usage, appropriate wound closure materials, and optimal surgical timing are needed.
Collapse
|
5
|
Guideline for Vascular Access Port Use and Maintenance in Large Animals for Biomedical Research. SURGERIES 2022. [DOI: 10.3390/surgeries3030024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Purpose Vascular Access Ports (VAPs) consist of an indwelling catheter connected to an implanted port that provides direct access for sample collection or infusion. The use of VAPs in biomedical research reduces trauma on vessels from repeated venipuncture, decreases secondary infections, promotes social housing and animal welfare, and increases the accuracy and efficiency of study procedures. In addition to enabling comprehensive data collection, VAPs increase satisfaction, and well-being by minimizing interference with daily routines and fostering cooperation. The responsible use of VAPs includes approval by the institutional animal care and use committee (IACUC), verification of the surgeon′s skill and experience, and confirmation that research staff are trained on the proper maintenance and access techniques. This document aims to provide surgeons, researchers and research staff, veterinary staff, and IACUCs with guidelines for implanting, maintaining, accessing, and troubleshooting vascular access ports in large animal species. (Rabbit, Canine, Feline, Nonhuman Primate, Porcine).
Collapse
|
6
|
El-Rashidy NM, El-Bakary MA, Omar EEZ, El-Sayed NM, Hamza AA. Phase estimation for investigating the optical and mechanical properties of Monocryl suture for soft tissue approximation and ligation. Microsc Res Tech 2022; 85:3455-3465. [PMID: 35804492 DOI: 10.1002/jemt.24201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 06/16/2022] [Accepted: 06/30/2022] [Indexed: 11/11/2022]
Abstract
Monocryl is a bio-absorbable suture composed of a polyglycolide and poly-epsiloncaprolactone copolymer material and is considered a promising candidate for soft tissues approximation. Consequently, the physical, mechanical, and morphological properties are essential for the surgeons to select the suitable suture for their surgical perform. In this article, Mach Zehnder interferometer equipped with a mechanical drawing device are used for evaluating the mechanical properties and a better understanding of how the Monocryl suture reacts to loading. The two-dimensional fast Fourier transform is applied to extract the phase from the captured interference microinterferograms at different draw ratios. The extracted phase helps to determine some opto-mechanical and structural properties of Monocryle suture. Quantitative structure-activity relationships model is employed for investigating the biological activity of the tested suture. The stress-strain behavior of Monocryl suture has a J-shaped behavior which compatible with the behavior of the soft tissues. The molecular electrostatic potential maps showed that Monocryl model structure is proved to be electrophilic interplays.
Collapse
Affiliation(s)
- Noha M El-Rashidy
- Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
| | | | - El-Emam Z Omar
- Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
| | - Nayera M El-Sayed
- Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
| | - Ahmed A Hamza
- Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
| |
Collapse
|
7
|
Adamo A, Bartolacci JG, Pedersen DD, Traina MG, Kim S, Pantano A, Ghersi G, Watkins SC, Wagner WR, Badylak SF, D'Amore A. Continuous Microfiber Wire Mandrel-Less Biofabrication for Soft Tissue Engineering Applications. Adv Healthc Mater 2022; 11:e2102613. [PMID: 35394654 DOI: 10.1002/adhm.202102613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 03/27/2022] [Indexed: 11/10/2022]
Abstract
Suture materials are the most common bioimplants in surgical and clinical practice, playing a crucial role in wound healing and tendon and ligament repair. Despite the assortment available on the market, sutures are still affected by significant disadvantages, including failure in mimicking the mechanical properties of the tissue, excessive fibrosis, and inflammation. This study introduces a mandrel-less electrodeposition apparatus to fabricate continuous microfiber wires of indefinite length. The mandrel-less biofabrication produces wires, potentially used as medical fibers, with different microfiber bundles, that imitate the hierarchical organization of native tissues, and tailored mechanical properties. Microfiber wire morphology and mechanical properties are characterized by scanning electron microscopy, digital image processing, and uniaxial tensile test. Wires are tested in vitro on monocyte/macrophage stimulation and in vivo on a rat surgical wound model. The wires produced by mandrel-less deposition show an increased M2 macrophage phenotype in vitro. The in vivo assessment demonstrates that microfiber wires, compared to the medical fibers currently used, reduce pro-inflammatory macrophage response and preserve their mechanical properties after 30 days of use. These results make this microfiber wire an ideal candidate as a suture material for soft tissue surgery, suggesting a crucial role of microarchitecture in more favorable host response.
Collapse
Affiliation(s)
- Arianna Adamo
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Ri. MED Foundation Palermo 90133 Italy
| | | | - Drake D. Pedersen
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
| | - Marco G. Traina
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Department of Engineering University of Palermo Palermo 90133 Italy
| | - Seungil Kim
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
| | - Antonio Pantano
- Department of Engineering University of Palermo Palermo 90133 Italy
| | - Giulio Ghersi
- Department of Biological Chemical and Pharmaceutical Sciences and Technologies Palermo 90123 Italy
| | - Simon C. Watkins
- Department of Cell Biology University of Pittsburgh School of Medicine Pittsburgh PA 15213 USA
| | - William R. Wagner
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
- Department of Surgery School of Medicine University of Pittsburgh Pittsburgh PA 15260 USA
- Department of Chemical Engineering University of Pittsburgh Pittsburgh PA 15260 USA
| | - Stephen F. Badylak
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
- Department of Surgery School of Medicine University of Pittsburgh Pittsburgh PA 15260 USA
| | - Antonio D'Amore
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15219 USA
- Ri. MED Foundation Palermo 90133 Italy
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
- Department of Surgery School of Medicine University of Pittsburgh Pittsburgh PA 15260 USA
- Clinical Translational Science Institute University of Pittsburgh Pittsburgh PA 15260 USA
| |
Collapse
|
8
|
Aldhabaan SA, Hudise JY, Aldosari BF. Comparison Between Using Monocryl Suture and Polypropylene Suture in Closure of Alar Base Excision in Rhinoplasty. Plast Surg (Oakv) 2022; 30:59-62. [PMID: 35096694 PMCID: PMC8793751 DOI: 10.1177/2292550320969651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Rhinoplasty is one of the most common procedures that act as a challenge for consistent outstanding results. Alar base reduction is a technique of rhinoplasty that is prescribed in many conditions. Wound closure requires using of sutures and there are several types of sutures for this purpose; however, good scar results are necessary for patients'satisfaction. AIM To evaluate alar base resection scar results after surgical resection using different types of suturing material. METHODS This is a retrospective cohort study that was conducted at King Abdulaziz University Hospital, Riyadh, Kingdom of Saudi Arabia. The study was performed by reviewing patient's records and performing post-operative photography for patient who underwent alar base resection. The patients were divided into 2 groups, the first group of patients had the alar base wound closed with interrupted Polypropylene 6/0 and the other group wound was closed with monocryl 6/0 sutures. Visual analog scale was used to investigate basal views. RESULTS The study included 80 patients divided into 2 groups, each group included 40 patients, in the first group (Polypropylene group) there were 25% males and 75% females, whereas in the second group (monocryl) there were 15% and 85% males and females, respectively. There were 85% and 82.5% unnoticeable scar reported by the first and second group, respectively; however there was no significant difference between the 2 groups (P = .75). CONCLUSION Both Polypropylene and monocryl sutures result in the same result for closing alar base wound post surgically.
Collapse
Affiliation(s)
- Saud A. Aldhabaan
- Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, Riyadh, Saudi Arabia,Saud A. Aldhabaan, Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia; King Fisal Medical City of Southern Region, Abha, Saudi Arabia.
| | - Jibril Y. Hudise
- Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, Riyadh, Saudi Arabia
| | - Badi F. Aldosari
- Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
9
|
Broida SE, Sweeney AP, Gottschalk MB, Wagner ER. Management of shoulder instability in hypermobility-type Ehlers-Danlos syndrome. JSES REVIEWS, REPORTS, AND TECHNIQUES 2021; 1:155-164. [PMID: 37588970 PMCID: PMC10426500 DOI: 10.1016/j.xrrt.2021.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Shoulder instability in hypermobile Ehlers-Danlos syndrome can result in lifelong pain and functional disability. Treatment in this population is complicated by the severe degree of instability as well as the underlying abnormalities of the joint connective tissue. Appropriate care for these patients requires a thorough understanding of the natural history of their disease, knowledge of the available treatment options, and certain special considerations. This article reviews the pathoanatomy, recognition, and management of shoulder instability in the patient with hypermobile Ehlers-Danlos syndrome.
Collapse
Affiliation(s)
- Samuel E. Broida
- Department of Orthopaedic Surgery, Emory University, Atlanta, GA, USA
| | - Aidan P. Sweeney
- Department of Orthopaedic Surgery, Emory University, Atlanta, GA, USA
| | | | - Eric R. Wagner
- Department of Orthopaedic Surgery, Emory University, Atlanta, GA, USA
| |
Collapse
|
10
|
de la Harpe KM, Kondiah PPD, Marimuthu T, Choonara YE. Advances in carbohydrate-based polymers for the design of suture materials: A review. Carbohydr Polym 2021; 261:117860. [PMID: 33766349 DOI: 10.1016/j.carbpol.2021.117860] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 02/12/2021] [Accepted: 02/22/2021] [Indexed: 12/25/2022]
Abstract
Suture materials constitute one of the largest biomedical material groups with a huge global market of $ 1.3 billion annually and employment in over 12 million procedures per year. Suture materials have radically evolved over the years, from basic strips of linen to more advanced synthetic polymer sutures. Yet, the journey to the ideal suture material is far from over and we now stand on the brink of a new era of improved suture materials with greater safety and efficacy. This next step in the evolutionary timeline of suture materials, involves the use of natural, carbohydrate polymers that have, until recent years, never before been considered for suture material applications. This review exposes the latest and most important advancements in suture material development while digging deep into how natural, carbohydrate polymers can serve to advance this field.
Collapse
Affiliation(s)
- Kara M de la Harpe
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown, 2193, South Africa
| | - Pierre P D Kondiah
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown, 2193, South Africa
| | - Thashree Marimuthu
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown, 2193, South Africa
| | - Yahya E Choonara
- Wits Advanced Drug Delivery Platform Research Unit, Department of Pharmacy and Pharmacology, School of Therapeutic Science, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 7 York Road, Parktown, 2193, South Africa.
| |
Collapse
|
11
|
Histotopographic and morphometric characteristics of the oral mucosa postoperative wounds healing, depending on the method of connecting the wound edges. EUREKA: HEALTH SCIENCES 2021. [DOI: 10.21303/2504-5679.2021.001845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Implementation of high-quality tissue connections and hemostasis in oral surgery is an urgent problem of modern dentistry, due to the lack of available universal methods that would help to facilitate the work of oral surgeon and reduce wound healing time.
The aim of the research. To investigate and study the regeneration processes in the oral mucosa after high-frequency electric welding, suturing and medical adhesive composition.
Materials and methods. This study compared the effect of three connection methods and hemostasis: high-frequency electric welding (EKVZ-300M1 “PATONMED®”, Ukraine), suture method (nylon 5/0 “PIRUS®”, China), adhesive composition (“Histoacryl®”, Germany). 72 rabbits were involved in experiment. An incision of the soft tissues of the vestibulum of the oral cavity of the maxilla with a length of 1.3–1.5 cm was made. On days 3, 7, 14 and 21, tissue samples were excised, histological and morphometric examination of the material were performed.
Results. By statistical data processing of 72 rabbits was found that the reliability of differences in the levels of morphometric parameters between groups on each day is very high, as evidenced by the calculated values of the U-test. In 38 cases (90.5 %), the significance level was p≤0.01, in the other 4 cases – p≤0.05. The lowest value level of neutrophilic granulocytes was in rabbits of group No.1 (electric welding). In rabbits of group No. 1 GFBC were not observed in the 8 fields of view throughout the experiment.
Conclusions. High-frequency electric welding of soft tissues can be used for effective intraoperative hemostasis and connection of the intraoral wound edges.
Due to the absence of a foreign body (adhesive masses, filaments) and moderate alterative effect, histological examination indicates accelerated activation of regenerative processes in the early stages of observation in rabbits of group No. 1.
Collapse
|
12
|
Baptista-Silva S, Borges S, Costa-Pinto AR, Costa R, Amorim M, Dias JR, Ramos Ó, Alves P, Granja PL, Soares R, Pintado M, Oliveira AL. In Situ Forming Silk Sericin-Based Hydrogel: A Novel Wound Healing Biomaterial. ACS Biomater Sci Eng 2021; 7:1573-1586. [PMID: 33729761 DOI: 10.1021/acsbiomaterials.0c01745] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
In situ cross-linked hydrogels have the advantage of effectively fulfilling the wound in its shape and depth. Amongst the new generation of natural-based biopolymers being proposed for wound care and skin regeneration, silk sericin is particularly interesting due to its exceptional properties such as biocompatibility, biodegradability, and antioxidant behavior, among others. In this study, a new enzyme-mediated cross-linked hydrogel composed of silk sericin is proposed for the first time. The developed hydrogel cross-linking strategy was performed via horseradish peroxidase, under physiological conditions, and presented gelling kinetics under 3 min, as demonstrated by its rheological behavior. The hydrogels presented a high degree of transparency, mainly due to their amorphous conformation. Degradation studies revealed that the hydrogels were stable in phosphate buffer solution (PBS) (pH 7.4) for 17 days, while in the presence of protease XIV (3.5 U/mg) and under acute and chronic physiological pH values, the stability decreased to 7 and 4 days, respectively. During protease degradation, the present sericin hydrogels demonstrated antioxidant activity. In vitro studies using an L929 fibroblast cell line demonstrated that these hydrogels were noncytotoxic, promoting cell adhesion and massive cell colonization after 7 days of culture, demonstrating that cells maintained their viability and proliferation. In addition, the application of sericin-based hydrogel in an in vivo diabetic wound model validated the feasibility of the in situ methodology and demonstrated a local anti-inflammatory effect, promoting the healing process. This study presents a simple, fast, and practical in situ approach to produce a sericin-based hydrogel able to be applied in low exudative chronic wounds. Moreover, the study herein reported fosters the valorization of a textile industrial by-product by its integration in the biomedical field.
Collapse
Affiliation(s)
- Sara Baptista-Silva
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Sandra Borges
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Ana Rita Costa-Pinto
- Universidade do Porto, i3S-Instituto de Investigação e Inovação em Saúde, Porto 4200-135, Portugal
| | - Raquel Costa
- Department of Biomedicine, Faculty of Medicine, University of Porto, Porto 4099-002, Portugal
| | - Manuela Amorim
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Juliana R Dias
- Centre for Rapid and Sustainable Product Development, Instituto Politécnico de Leiria, Zona Industrial, Marinha Grande 2430-028, Portugal
| | - Óscar Ramos
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Paulo Alves
- Centre for Interdisciplinary Research in Health (CIIS)-Wounds Research Lab, Universidade Católica Portuguesa, ICS-Instituto de Ciências da Saúde, Porto 4169-005, Portugal
| | - Pedro Lopes Granja
- Universidade do Porto, i3S-Instituto de Investigação e Inovação em Saúde, Porto 4200-135, Portugal
| | - Raquel Soares
- Department of Biomedicine, Faculty of Medicine, University of Porto, Porto 4099-002, Portugal
| | - Manuela Pintado
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Ana Leite Oliveira
- Universidade Católica Portuguesa, CBQF-Centro de Biotecnologia e Química Fina-Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| |
Collapse
|
13
|
Conde AL, Santos CHMD, Dourado DM, Tanus OAV, Souza IFD, Costa RL, Giuncanse F, Costa IO. Evaluation of polypropylene and polyglactin sutures in primary sphincteroplasty for the treatment of anal fistula in rats. JOURNAL OF COLOPROCTOLOGY 2021. [DOI: 10.1016/j.jcol.2019.05.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Abstract
Rationale Fistulotomy followed by primary sphincteroplasty is one of the therapeutic options in transsphincteric fistulae; however, it was not known which suture would present a better result.
Objective To compare polypropylene and polyglactin sutures in primary sphincteroplasty in rats subjected to fistulotomy.
Method Thirty Wistar rats were subjected to peritoneal anesthesia with ketamine and xylazine, followed by transfixation of the anal sphincter with steel thread, which remained for 30 days to develop the anal fistula. After this period, the steel thread was removed and four groups were formed: A – Control (n = 5), without treatment; B – Fistulotomy (n = 5), performed fistulotomy only; C – Polypropylene (n = 10), in which fistulotomy was performed followed by primary sphincteroplasty with polypropylene suture; D – Polyglactin (n = 10), in which fistulotomy was performed followed by primary sphincteroplasty with polyglactin suture; after 30 days the animals were anesthetized again and submitted to euthanasia by deepening the anesthetic plane to remove the specimens, analyzing fistula closure, muscle fiber distance, and inflammatory process.
Results The fistula persisted in all animals of the control group and in none of the other groups; the distances between the muscle fibers were 1620 μm, 4665 μm, and 2520 μm, respectively in Groups B, C, and D (p = 0.067); in relation to fibrosis, the means were 2.4, 2.8, and 3.6, respectively in Groups B, C, and D, showing greater fibrosis in the latter group (p = 0.041).
Conclusion There was no persistence of the fistula in any of the treated animals; there was no difference in the distance between the muscle fibers between the groups subjected to primary sphincteroplasty with polypropylene or polyglactin, or between these groups and the one treated only by fistulotomy. There was greater fibrosis in animals treated with primary sphincteroplasty with polyglactin.
Collapse
Affiliation(s)
- Andrea Lima Conde
- Universidade Federal de Mato Grosso do Sul, Hospital Universitário Maria Aparecida Pedrossian, Campo Grande, MS, Brazil
| | - Carlos Henrique Marques dos Santos
- Universidade Federal de Mato Grosso do Sul, Hospital Universitário Maria Aparecida Pedrossian, Campo Grande, MS, Brazil
- Universidade Anhanguera-Uniderp, Campo Grande, MS, Brazil
| | | | - Otávio Augusto Vendas Tanus
- Universidade Federal de Mato Grosso do Sul, Hospital Universitário Maria Aparecida Pedrossian, Campo Grande, MS, Brazil
| | | | | | | | | |
Collapse
|
14
|
Sharma AK, Thulasi Doss GP, Panneerselvam E, Ganesh SK, Krishna Kumar Raja VB. Use of knotless barbed sutures for closure of intraoral incisions for maxillofacial trauma: a randomised controlled trial. Br J Oral Maxillofac Surg 2020; 59:e72-e78. [PMID: 33384176 DOI: 10.1016/j.bjoms.2020.08.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/10/2020] [Indexed: 11/17/2022]
Abstract
The objective of this study was to assess the efficacy of knotless barbed sutures in intraoral wound closure for maxillofacial trauma in comparison with conventional (vicryl) sutures. This was a randomised controlled clinical trial involving 40 patients with isolated mandibular angle fractures who required intraoral incisions for open reduction and internal fixation (ORIF). The sample was randomised into the study group (20 patients) and control group (20 patients). Following fracture fixation by a standardised surgical protocol, the wound closure was done with bidirectional knotless barbed suture and vicryl for the study and control groups, respectively. The wounds were closed in layers (periosteum and mucosa). All operations were performed by a single surgeon. Outcome parameters measured were intraoperative wound closure time and wound healing using 'Landry's wound healing index' on the first, third, and seventh postoperative days. Statistically significant difference in suturing time was noted between the study and control group (p value <0.001). The study group demonstrated a mean (SD) suturing time of 9.46 (2.01) minutes, compared with the 17.61 (2.57) minutes in the control group. Wound healing was found to be better and statistically significant in the study group than the control group (p value<0.001). Knotless barbed suture is a promising alternative to vicryl for intraoral wound closure.
Collapse
Affiliation(s)
- A K Sharma
- Department of Oral & Maxillofacial Surgery, SRM Dental College & Hospital, Ramapuram Campus, Ramapuram, Chennai
| | - G P Thulasi Doss
- Department of Oral & Maxillofacial Surgery, SRM Dental College & Hospital, Ramapuram Campus, Ramapuram, Chennai
| | - E Panneerselvam
- Department of Oral & Maxillofacial Surgery, SRM Dental College & Hospital, Ramapuram Campus, Ramapuram, Chennai
| | - S K Ganesh
- Department of Oral & Maxillofacial Surgery, SRM Dental College & Hospital, Ramapuram Campus, Ramapuram, Chennai.
| | - V B Krishna Kumar Raja
- Department of Oral & Maxillofacial Surgery, SRM Dental College & Hospital, Ramapuram Campus, Ramapuram, Chennai
| |
Collapse
|
15
|
Akentyeva TN, Mukhamadiyarov RA, Krivkina EO, Luzgarev SV, Kudryavtseva YA. [Influence of unmodified and modified sutures on experimental abdominal adhesive process]. Khirurgiia (Mosk) 2020:29-34. [PMID: 32271734 DOI: 10.17116/hirurgia202003129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Experimental assessment of the effect of modified and unmodified surgical suture material on abdominal adhesive process. MATERIAL AND METHODS The study was performed on male rats of the Wistar subpopulation. There were 5 animals in each group. In all animals, midline abdominal incision was followed by suturing the parietal peritoneum with modified and unmodified suture material. All animals were euthanized with carbon dioxide vapors in 14 days after surgery. Macro- and microscopic assessment of severity of abdominal adhesive process was carried out. Two types of preparation of excised complexes 'peritoneum-suture material-adhesion' were applied for histological examination: paraffin sections and embedding in epoxy resin. Specimens were stained by Van Gieson and with methylene blue solution. Histological specimens were examined using Axio Imager A1 light microscope (Zeiss, Germany). RESULTS Polypropylene filaments result extensive adhesions occupying about 75% of the area. Adhesions have a dense structure with signs of vascularization. Modification of suture material with solution of polyhydroxybutyrate/hydroxyvalerate and heparin reduce severity of adhesions. The use of modified suture material was followed by adhesions with more loose structure, no signs of vascularization. Adhesions occupied less than 25% of the area. Histological examination of excised complexes 'peritoneum-suture material-adhesion' revealed accumulation of inflammatory cells around the unmodified suture material, while there were no signs of tissue inflammatory process around the modified sutures. CONCLUSION Application of polyhydroxybutyrate/hydroxyvalerate and heparin on the surface of surgical sutures is an effective method for prevention of abdominal adhesions.
Collapse
Affiliation(s)
- T N Akentyeva
- Research Institute for Complex Problems of Cardiovascular Diseases, Kemerovo, Russia
| | - R A Mukhamadiyarov
- Research Institute for Complex Problems of Cardiovascular Diseases, Kemerovo, Russia
| | - E O Krivkina
- Research Institute for Complex Problems of Cardiovascular Diseases, Kemerovo, Russia
| | - S V Luzgarev
- Research Institute for Complex Problems of Cardiovascular Diseases, Kemerovo, Russia
| | - Yu A Kudryavtseva
- Research Institute for Complex Problems of Cardiovascular Diseases, Kemerovo, Russia
| |
Collapse
|
16
|
Muhar AM, Putra A, Warli SM, Munir D. Hypoxia-Mesenchymal Stem Cells Inhibit Intra-Peritoneal Adhesions Formation by Upregulation of the IL-10 Expression. Open Access Maced J Med Sci 2019; 7:3937-3943. [PMID: 32165932 PMCID: PMC7061407 DOI: 10.3889/oamjms.2019.713] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 10/19/2019] [Accepted: 10/20/2019] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Intra-peritoneal adhesions (IPAs) common occurre in post abdominal surgical. Athough many methods have been developed for controlling IPAs, including mesenchymal stem cells (MSCs) application, however, there is none completely preventing in due to the mesothelial structure may promote the prolonged inflammations leading. Nevertheless hypoxia-MSCs (H-MSCs) have more potent in controlling the inflammation than normoxia-MSCs (N-MSCs) by releasing several anti-inflamation particularly IL-10, however the H-MSCs application to inhibit IPAs remain unclear. AIM The aim of this study was to investigate the effectiveness of H-MSCs in preventing the AIPs event by releasing IL-10 on the ileum abrasion sutured omental patch as the animal model of peritoneal adhesion. METHODS Using 24 IPAs animal model were randomly divided into 4 groups: Sham (Sh), Control (C), H-MSCs at high dose (T1) and H-MSCs at low dose (T2). H-MSCs were incubated under hypoxic conditions (5% O2), 37°C and 5% CO2 for 24 hours. The expression level of IL-10 was performed using RT-PCR analysis. The macroscopic appearance of IPAs was evaluated using Nair's scale base on the absence/presence of adhesion, whereas the microscopic by Zuhlke's scale at Hematoxylin and eosin (H&E) staining. RESULTS This study showed a significanly increase in IL-10 expression (p < 0.05) at all T groups. In line with this, we also found a significant difference in IPAs between T groups and Control as well as a Sham (p < 0.05) either in the macroscopic or microscopic analysis. CONCLUSION H-MSCs has a robust ability in inhibiting severe IPAs characterized by the decreased of adhesion formation and the enhanced expression of IL-10.
Collapse
Affiliation(s)
- Adi Muradi Muhar
- Department of Doctoral Degree Program, Medical Faculty, Universitas Sumatera Utara, Medan, North Sumatera, Indonesia
| | - Agung Putra
- Stem Cell And Cancer Research (SCCR), Medical Faculty, Sultan Agung Islamic University (UNISSULA), Semarang, Central Java, Indonesia.,Department of Postgraduate Biomedical Science, Medical Faculty, Sultan Agung Islamic University (UNISSULA), Semarang, Central Java, Indonesia.,Department of Pathological Anatomy, Medical Faculty, Sultan Agung Islamic University (UNISSULA), Semarang, Central Java, Indonesia
| | - Syah Mirsya Warli
- Department of Urology, Medical Faculty, Universitas Sumatera Utara, Medan, North Sumatera, Indonesia
| | - Delfitri Munir
- Pusat Unggulan Inovasi (PUI) Stem Cell, Universitas Sumatera Utara (USU), Medan, North Sumatera, Indonesia
| |
Collapse
|
17
|
Choi Y, Kang M, Choi MS, Kim Song J, Lih E, Lee D, Jung HH. Biomechanical Properties and Biocompatibility of a Non-Absorbable Elastic Thread. J Funct Biomater 2019; 10:E51. [PMID: 31744160 PMCID: PMC6963933 DOI: 10.3390/jfb10040051] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 11/05/2019] [Accepted: 11/09/2019] [Indexed: 12/11/2022] Open
Abstract
To date, extensive studies have been conducted to assess diverse types of sutures. But there is a paucity of data regarding biomechanical properties of commonly used suture materials. In the current experiment, we compared biomechanical properties and biocompatibility, such as tensile strength and elongation, the degree of bovine serum albumin (BSA) release, in vitro cytotoxicity and ex vivo frictional properties, between a non-absorbable elastic thread (NAT; HansBiomed Co. Ltd., Seoul, Korea) (NAT-R: NAT with a rough surface, NAT-S: NAT with a smooth surface) and the Elasticum® (Korpo SRL, Genova, Italy). The degree of tensile strength and elongation of Si threads was significantly higher in both the NAT-R and -S as compared with the Elasticum® (p < 0.05). Moreover, the degree of tensile strength and elongation of PET threads was significantly lower in both NAT-R and -S as compared with the Elasticum® (p < 0.05). Furthermore, the degree of tensile strength and elongation of braided Si/PET threads was significantly lower in NAT-S as compared with NAT-R and Elasticum® (p < 0.05). The degree of BSA release was significantly higher in the NAT-R as compared with Elasticum® and NAT-S throughout a 2-h period in the descending order (p < 0.05). The degree of cell viability was significantly higher in both NAT-R and -S as compared with Elasticum® (p < 0.05). The degree of coefficient of friction as well as the frictional force and strength was significantly higher in NAT-R as compared with NAT-S and Elasticum® (p < 0.05). NAT had a higher degree of biomechanical properties and biocompatibility as compared with Elasticum®. But further experimental and clinical studies are warranted to compare the efficacy, safety, and potential role as a carrier for drug delivery between NAT and Elasticum®.
Collapse
Affiliation(s)
- Yeji Choi
- Advanced Medical Device R&D Center, HansBiomed Co. Ltd., 7, Jeongui-ro 8-gil, Songpa-gu, Seoul 05836, Korea; (Y.C.); (E.L.); (D.L.)
| | | | | | | | - Eugene Lih
- Advanced Medical Device R&D Center, HansBiomed Co. Ltd., 7, Jeongui-ro 8-gil, Songpa-gu, Seoul 05836, Korea; (Y.C.); (E.L.); (D.L.)
| | - Deahyung Lee
- Advanced Medical Device R&D Center, HansBiomed Co. Ltd., 7, Jeongui-ro 8-gil, Songpa-gu, Seoul 05836, Korea; (Y.C.); (E.L.); (D.L.)
| | - Hong-Hee Jung
- Advanced Medical Device R&D Center, HansBiomed Co. Ltd., 7, Jeongui-ro 8-gil, Songpa-gu, Seoul 05836, Korea; (Y.C.); (E.L.); (D.L.)
| |
Collapse
|
18
|
Akentieva TN, Ovcharenko EA, Kudryavtseva YA. [Influence of suture material on the development of postoperative complications in vascular surgery and their prevention]. Khirurgiia (Mosk) 2019:75-81. [PMID: 31626243 DOI: 10.17116/hirurgia201910175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Postoperative complications in vascular surgery may be partly provoked by suture material. Analysis of the mechanisms of these complications may be useful for their prevention. Mechanisms of suture-induced thrombosis and neointimal hyperplasia, possible strategies for prevention of postoperative complications including those allowing drug deliveries directly to the vascular anastomosis area are discussed in the article. According to the literature data, heparin is the most optimal drug for modifying suture material and prevention of thrombosis and neointimal hyperplasia. Heparin delivery to the vascular anastomosis site will reduce the risk of thrombosis by inhibiting the activity of thrombin. Complex of heparin and antithrombin III increases inhibitory effect of antithrombin against thrombin. In addition, heparin is able to reduce proliferation of vascular smooth muscle cells through inhibition of the synthesis of extracellular matrix proteases involved in migration and proliferation of cells. Thus, heparin delivery to the vascular injury site may be used to prevent thrombosis and myoproliferative response. Moreover, this strategy prevents complications associated with systemic administration of anticoagulants.
Collapse
Affiliation(s)
- T N Akentieva
- Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
| | - E A Ovcharenko
- Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
| | - Yu A Kudryavtseva
- Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
| |
Collapse
|
19
|
COSTA RC, CAVALCANTI YW, VALENÇA AMG, ALMEIDA LDFDD. Sutures modified by incorporation of chlorhexidine and cinnamaldehyde: anti-Candida effect, bioavailability and mechanical properties. REVISTA DE ODONTOLOGIA DA UNESP 2019. [DOI: 10.1590/1807-2577.04219] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Abstract Introduction Antimicrobial sutures are a therapeutic alternative for the control of oral infections. Objective Incorporate Chlorhexidine (CHX) and Cinnamaldehyde (CN) in sutures and evaluate the anti-Candida effect, release of antimicrobials and mechanical properties. Material and method Silk (S) and Polyglactin 910 (P) sutures were aseptically sectioned (20 mm) and immersed for incorporation in 0.12% CHX, 0.4% CN and 0.9% saline solutions under stirring for 60 minutes (n = 10 / group). Suspensions of 500 μL of Candida albicans (ATCC 90028/ 1 × 106 CFU/mL) were used to evaluate fungal adhesion after the 48 h period at 37°C. The release of CLX and CN were evaluated at 0, 24 and 48 hours (n=3/group) by UV-VIS spectrophotometer (275 nm). The tensile strength and displacement (n=5/group) were evaluated after incorporation (30 mm/min, 50N). Data were analyzed by Anova and Tukey (α = 5%). Result No anti-Candida effect was observed on S and P sutures incorporated with CLX and CN (p>0.05). However, progressive release was verified up to 48 after treatment with CLX (S = 0.075 / P = 0.073 μg/mL) and CN (S = 35.33 /P= 5.72 μg/mL). There was a decrease in tensile strength in S (CLX = 9.9 / CN = 9.9 N) and P (CLX = 14.4 / CN = 15.5 N) (p<0.05). No differences were observed for the displacement for S (CLX = 19.3 / CN=20.7 mm) and P (CLX = 16.2 / CN=15.8 mm) (p>0.05). Conclusion The incorporation of CLX and CN did not have a positive effect on the biological and mechanical properties of the sutures evaluated.
Collapse
|