1
|
Aoki J, Wakaki S, Ishiniwa H, Kawakami T, Miyazaki T, Suzuki K, Takagai Y. Direct Quantification of Attogram Levels of Strontium-90 in Microscale Biosamples Using Isotope Dilution-Thermal Ionization Mass Spectrometry Assisted by Quadrupole Energy Filtering. Anal Chem 2023; 95:4932-4939. [PMID: 36906855 DOI: 10.1021/acs.analchem.2c04844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2023]
Abstract
Although thermal ionization mass spectrometry (TIMS) has been employed for the high-precision analysis of isotope ratios, direct quantification of artificial mono-nuclide in the environment is difficult by even using isotope dilution (ID) due to the coexistence of the great magnitude of natural stable nuclides or isobars. In traditional TIMS and ID-TIMS, a sufficient amount of stable Sr doped on a filament is required to realize a stable and adequate ion-beam intensity (i.e., thermally ionized beams). However, the background noise (BGN) at m/z 90, detected by an electron multiplier, disturbs 90Sr analysis at low concentration levels due to peak tailing of a significant 88Sr ion beam dependent on the 88Sr-doping amount. Here, TIMS assisted by quadruple energy filtering was successfully employed for the direct quantification of attogram levels of an artificial monoisotopic radionuclide strontium-90 (90Sr) in microscale biosamples. Direct quantification was achieved by integrating the ID quantification of natural Sr and simultaneous 90Sr/86Sr isotope ratio analysis. Additionally, the measurement amount calculated by the combination of the ID and intercalibration was corrected for the net result amount of 90Sr by subtracting dark noise and the detected amount derived from the survived 88Sr, which are equivalent with the BGN intensity at m/z 90. Background correction revealed that the detection limits were in the range of 6.15 × 10-2-3.90 × 10-1 ag (0.31-1.95 μBq), depending on the concentration of natural Sr in a 1 μL sample, and the quantification of 0.98 ag (5.0 μBq) of 90Sr in 0-300 mg/L of natural Sr was successful. This method could analyze small sample quantities (1 μL), and the quantitative results were verified against authorized radiometric analysis techniques. Furthermore, the amount of 90Sr in actual teeth was successfully quantified. This method will be a powerful tool for measuring 90Sr in the measurement of micro-samples, which are required to assess and understand the degree of internal radiation exposure.
Collapse
Affiliation(s)
- Jo Aoki
- Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
| | - Shigeyuki Wakaki
- Kochi Institute for Core Sample Research, Japan Agency for Marine-Earth Science and Technology (JAMSTEC), 200 Monobe Otsu, Nankoku, Kochi 783-8502, Japan
| | - Hiroko Ishiniwa
- Institute of Environmental Radioactivity, Fukushima University, 1 Kanayagawa, Fukushima 960-1296 Japan
| | | | - Takashi Miyazaki
- Japan Agency for Marine-Earth Science and Technology (JAMSTEC), 2-15 Natushima, Yokosuka, Kanagawa 237-0061, Japan
| | - Katsuhiko Suzuki
- Japan Agency for Marine-Earth Science and Technology (JAMSTEC), 2-15 Natushima, Yokosuka, Kanagawa 237-0061, Japan
| | - Yoshitaka Takagai
- Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
- Institute of Environmental Radioactivity, Fukushima University, 1 Kanayagawa, Fukushima 960-1296 Japan
| |
Collapse
|
2
|
Soylak M, Sevicin AO, Uzcan F. Preconcentration of Nickel by Magnetic Solid-Phase Extraction (MSPE) as the 2-(5-Bromo-2-Pyridylazo)-5-Diethylamino-Phenol (PADAP) Chelate upon Multiwalled Carbon Nanotubes (MWCNTs) with Determination by Flame Atomic Absorption Spectrometry (FAAS). ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2046770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Mustafa Soylak
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
- Turkish Academy of Sciences (TUBA), Cankaya, Ankara, Turkey
| | - Ali Osman Sevicin
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
| | - Furkan Uzcan
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
| |
Collapse
|
3
|
A part per trillion isotope ratio analysis of 90Sr/ 88Sr using energy-filtered thermal ionization mass spectrometry. Sci Rep 2022; 12:1151. [PMID: 35064171 PMCID: PMC8783016 DOI: 10.1038/s41598-022-05048-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 01/06/2022] [Indexed: 11/28/2022] Open
Abstract
Strontium-90 is a major radioactive nuclide released by nuclear accidents and discharge waste. Input of such radioactive nuclide into earth surface environment causes potential threat of long-term internal exposure when taken up by organism. Rapid and precise measurement of 90Sr in variety of environmental sample is important to understand the distribution and dynamics of 90Sr in the local environment after the accident and to assess the effect of radioactive nuclide inputs on bodies. However, previous 90Sr measurement techniques have drawbacks such as long measurement times for radiometry and high detection limits for mass spectrometry. Here we present a technique to accurately measure a significantly small amount of 90Sr in natural environmental samples using an energy-filtered thermal ionization mass spectrometry. Our technique achieved a 90Sr detection limit of 0.23 ag, which corresponds to a 90Sr activity of 1.2 µBq. The detection limit was lowered by two orders of magnitude compared with the previous mass spectrometric 90Sr analyses. The ability of our technique will expand the applicability of mass spectrometric 90Sr survey not only to the rapid 90Sr survey upon nuclear accidents but also to study a long-term environmental diffusion of radioactive materials using size-limited environmental and biological samples.
Collapse
|
4
|
Ito C, Shimode R, Miyazaki T, Wakaki S, Suzuki K, Takagai Y. Isotope Dilution-Total Evaporation-Thermal Ionization Mass Spectrometric Direct Determination of Radioactive Strontium-90 in Microdrop Samples. Anal Chem 2020; 92:16058-16065. [PMID: 33172270 DOI: 10.1021/acs.analchem.0c03673] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Thermal ionization mass spectrometry (TIMS) was used to directly quantify an ultratrace of radioactive 90Sr in microliter droplet samples. No chemical separation was required in removing isobaric interferences on M = 90 such as 90Zr and organic molecules in the mass spectrum because the difference in evaporation and ionization (emission) temperature among organic molecules, Zr and Sr, allows us to control the emission manner and significantly suppress the isobaric interferences. Direct quantification was achieved by improving the intercalibration of Faraday cups and ion counting in an isotope dilution (ID) method. Furthermore, the use of a total evaporation method (TE) enhanced the detection efficiency by the complete collection of the 90Sr ion beam from the samples and minimized the complexity of the fractionation effect in the isotope ratio calculation. In this study, 1 fg of 90Sr (equal to activity of 5 millibecquerel (mBq)) in a very low-volume sample with 108 times greater isobaric interference from 90Zr was successfully measured using the proposed ID-TE-TIMS method. The limit of detection was 0.029 fg (equal to 0.15 mBq) without any preconcentration. To demonstrate the wide usability of this method, low-volume samples of tears, eyelashes, saliva, environmental standards, and water samples (i.e., seawater and ground water) were analyzed within 1 h. The relationship of the measured values between this ID-TE-TIMS method and a radiometric analysis was shown to have good linearity.
Collapse
Affiliation(s)
- Chihiro Ito
- Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
| | - Ryoya Shimode
- Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
| | - Takashi Miyazaki
- Japan Agency for Marine-Earth Science and Technology (JAMSTEC), 2-15 Natushima, Yokosuka, Kanagawa 237-0061, Japan
| | - Shigeyuki Wakaki
- Kochi Institute for Core Sample Research, JAMSTEC, 200 Monobe Otsu, Nankoku, Kochi 783-8502, Japan
| | - Katsuhiko Suzuki
- Japan Agency for Marine-Earth Science and Technology (JAMSTEC), 2-15 Natushima, Yokosuka, Kanagawa 237-0061, Japan
| | - Yoshitaka Takagai
- Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan.,Institute of Environmental Radioactivity, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
| |
Collapse
|