1
|
Dong L, Yang R, Xie A, Wang X, Feng Z, Li F, Ren J, Li J, Yao D. Transforming of scalp EEGs with different channel locations by REST for comparative study. Brain Res Bull 2024; 217:111064. [PMID: 39232993 DOI: 10.1016/j.brainresbull.2024.111064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 08/11/2024] [Accepted: 08/30/2024] [Indexed: 09/06/2024]
Abstract
OBJECTIVE The diversity of electrode placement systems brought the problem of channel location harmonization in large-scale electroencephalography (EEG) applications to the forefront. Therefore, our goal was to resolve this problem by introducing and assessing the reference electrode standardization technique (REST) to transform EEGs into a common electrode distribution with computational zero reference at infinity offline. METHODS Simulation and eye-closed resting-state EEG datasets were used to investigate the performance of REST for EEG signals and power configurations. RESULTS REST produced small errors (the root mean square error (RMSE): 0.2936-0.4583; absolute errors: 0.2343-0.3657) and high correlations (>0.9) between the estimated signals and true ones. The comparison of configuration similarities in power among various electrode distributions revealed that REST induced infinity reference could maintain a perfect performance similar (>0.9) to that of true one. CONCLUSION These results demonstrated that REST transformation could be adopted to resolve the channel location harmonization problem in large-scale EEG applications.
Collapse
Affiliation(s)
- Li Dong
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China; Research Unit of NeuroInformation, Chinese Academy of Medical Sciences, Chengdu 2019RU035, China; Sichuan Institute for Brain Science and Brain-Inspired Intelligence, Chengdu, China
| | - Runchen Yang
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Ao Xie
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Xinrui Wang
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Zongwen Feng
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Fali Li
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Junru Ren
- Sichuan Institute for Brain Science and Brain-Inspired Intelligence, Chengdu, China
| | - Jianfu Li
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Dezhong Yao
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for Neuroinformation, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China; Research Unit of NeuroInformation, Chinese Academy of Medical Sciences, Chengdu 2019RU035, China; Sichuan Institute for Brain Science and Brain-Inspired Intelligence, Chengdu, China; School of Electrical Engineering, Zhengzhou University, Zhengzhou 450001, China.
| |
Collapse
|
2
|
Yang Y, Luo S, Wang W, Gao X, Yao X, Wu T. From bench to bedside: Overview of magnetoencephalography in basic principle, signal processing, source localization and clinical applications. Neuroimage Clin 2024; 42:103608. [PMID: 38653131 PMCID: PMC11059345 DOI: 10.1016/j.nicl.2024.103608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 04/14/2024] [Accepted: 04/16/2024] [Indexed: 04/25/2024]
Abstract
Magnetoencephalography (MEG) is a non-invasive technique that can precisely capture the dynamic spatiotemporal patterns of the brain by measuring the magnetic fields arising from neuronal activity along the order of milliseconds. Observations of brain dynamics have been used in cognitive neuroscience, the diagnosis of neurological diseases, and the brain-computer interface (BCI). In this study, we outline the basic principle, signal processing, and source localization of MEG, and describe its clinical applications for cognitive assessment, the diagnoses of neurological diseases and mental disorders, preoperative evaluation, and the BCI. This review not only provides an overall perspective of MEG, ranging from practical techniques to clinical applications, but also enhances the prevalent understanding of neural mechanisms. The use of MEG is expected to lead to significant breakthroughs in neuroscience.
Collapse
Affiliation(s)
- Yanling Yang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; College of Medical Imaging, Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Shichang Luo
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; College of Medical Imaging, Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Wenjie Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; College of Medical Imaging, Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Xiumin Gao
- School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Xufeng Yao
- College of Medical Imaging, Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, China.
| | - Tao Wu
- College of Medical Imaging, Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, China
| |
Collapse
|
3
|
Normative Structure of Resting-State EEG in Bipolar Derivations for Daily Clinical Practice: A Pilot Study. Brain Sci 2023; 13:brainsci13020167. [PMID: 36831710 PMCID: PMC9953767 DOI: 10.3390/brainsci13020167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/12/2023] [Accepted: 01/16/2023] [Indexed: 01/20/2023] Open
Abstract
We used numerical methods to define the normative structure of resting-state EEG (rsEEG) in a pilot study of 37 healthy subjects (10-74 years old), using a double-banana bipolar montage. Artifact-free 120-200 s epoch lengths were visually identified and divided into 1 s windows with a 10% overlap. Differential channels were grouped by frontal, parieto-occipital, and temporal lobes. For every channel, the power spectrum was calculated and used to compute the area for delta (0-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), and beta (13-30 Hz) bands and was log-transformed. Furthermore, Shannon's spectral entropy (SSE) and coherence by bands were computed. Finally, we also calculated the main frequency and amplitude of the posterior dominant rhythm. According to the age-dependent distribution of the bands, we divided the patients in the following three groups: younger than 20; between 21 and 50; and older than 51 years old. The distribution of bands and coherence was different for the three groups depending on the brain lobes. We described the normative equations for the three age groups and for every brain lobe. We showed the feasibility of a normative structure of rsEEG picked up with a double-banana montage.
Collapse
|
4
|
Fang T, Song Z, Mu W, Le S, Zhang Y, Zhang X, Zhan G, Wang P, Wang J, Bin J, Zhang F, Zhang L, Kang X. Comparison of MI-EEG Decoding in Source to Sensor Domain. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3586-3589. [PMID: 36083918 DOI: 10.1109/embc48229.2022.9871186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Brain-computer interface (BCI) system based on sensorimotor rhythm (SMR) is a more natural brain-computer interaction system. In this paper, we propose a new multi-task motor imagery EEG (MI-EEG) classification framework. Unlike traditional EEG decoding algorithms, we perform the decoding task in the source domain rather than the sensor domain. In the proposed algorithm, we first build a conduction model of the signal using the public ICBM152 head model and the boundary element method (BEM). The sensor domain EEG was then mapped to the selected cortex region using standardized low-resolution electromagnetic tomography (sLORETA) technology, which benefit to address volume conduction effects problem. Finally, the source domain features are extracted and classified by combining FBCSP and simple LDA. The results show that the classification-decoding algorithm performed in the source domain can well solve the classification task of MI-EEG. In addition, we found that the source imaging method can significantly increase the number of available EEG channels, which can be expanded at least double. The preliminary results of this study encourage the implementation of EEG decoding algorithms in the source domain. Clinical Relevance- This confirms that better results can be obtained by performing MI-EEG decoding in the source domain than in the sensor domain.
Collapse
|
5
|
Liu Z, Wang X, Zhu M, He Y, Li L, Chen L, Huang W, Wei Z, Chen S, Chen Y, Li G. The Effects of Different Reference Methods on Decision-Making Implications of Auditory Brainstem Response. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:9923214. [PMID: 35432587 PMCID: PMC9012648 DOI: 10.1155/2022/9923214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 03/10/2022] [Indexed: 11/18/2022]
Abstract
Hearing loss is a common disease affecting public health all around the world. In clinic, auditory brainstem response (ABR) has been widely used for the detection of hearing loss based on its convenience and accuracy. The different reference methods directly influence the quality of the ABR waveform which in turn affects the ABR-based diagnosis. Therefore, in this study, a reference electrode standardization technique (REST) was adopted to systematically investigate and evaluate the effect of different reference methods on the quality of ABR waveform in comparison with the conventional average reference (AR) and mean mastoid (MM) methods. In this study, ABR signals induced by click stimulus were acquired via an EEG electrode cap arrays, and those located on the six channels along the midline were compared systemically. The results showed that, when considering the different channels, the ABR in the Cz channel showed the best morphology. Then, the ABR waveforms acquired via the REST method possessed better morphologies with large amplitude (0.06 ± 0.02 μV for wave I, 0.07 ± 0.02 μV for wave III, and 0.21 ± 0.04 μV for wave V) when compared with the traditional method. Summarily, we found that the REST and MM methods improved the quality of ABR on both amplitude and morphology under different stimulation rates and levels without changing the latencies of ABR when compared with the conventional AR method, suggesting that the REST and MM methods have the potential to help physicians with high accurate ABR-based clinical diagnosis. Moreover, this study might also provide a theoretic basis of reference methods on the acquisition of electroencephalogram over public health issues.
Collapse
Affiliation(s)
- Zhenzhen Liu
- Surgery Division, Epilepsy Center, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Xin Wang
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Mingxing Zhu
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yuchao He
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lin Li
- Surgery Division, Epilepsy Center, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Li Chen
- Department of Neurology, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Weimin Huang
- Department of Neonatology, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Zhilong Wei
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Shixiong Chen
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yan Chen
- Surgery Division, Epilepsy Center, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Guanglin Li
- The CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
- Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
6
|
Prado P, Birba A, Cruzat J, Santamaría-García H, Parra M, Moguilner S, Tagliazucchi E, Ibáñez A. Dementia ConnEEGtome: Towards multicentric harmonization of EEG connectivity in neurodegeneration. Int J Psychophysiol 2022; 172:24-38. [PMID: 34968581 PMCID: PMC9887537 DOI: 10.1016/j.ijpsycho.2021.12.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 11/26/2021] [Accepted: 12/19/2021] [Indexed: 02/02/2023]
Abstract
The proposal to use brain connectivity as a biomarker for dementia phenotyping can be potentiated by conducting large-scale multicentric studies using high-density electroencephalography (hd- EEG). Nevertheless, several barriers preclude the development of a systematic "ConnEEGtome" in dementia research. Here we review critical sources of variability in EEG connectivity studies, and provide general guidelines for multicentric protocol harmonization. We describe how results can be impacted by the choice for data acquisition, and signal processing workflows. The implementation of a particular processing pipeline is conditional upon assumptions made by researchers about the nature of EEG. Due to these assumptions, EEG connectivity metrics are typically applicable to restricted scenarios, e.g., to a particular neurocognitive disorder. "Ground truths" for the choice of processing workflow and connectivity analysis are impractical. Consequently, efforts should be directed to harmonizing experimental procedures, data acquisition, and the first steps of the preprocessing pipeline. Conducting multiple analyses of the same data and a proper integration of the results need to be considered in additional processing steps. Furthermore, instead of using a single connectivity measure, using a composite metric combining different connectivity measures brings a powerful strategy to scale up the replicability of multicentric EEG connectivity studies. These composite metrics can boost the predictive strength of diagnostic tools for dementia. Moreover, the implementation of multi-feature machine learning classification systems that include EEG-based connectivity analyses may help to exploit the potential of multicentric studies combining clinical-cognitive, molecular, genetics, and neuroimaging data towards a multi-dimensional characterization of the dementia.
Collapse
Affiliation(s)
- Pavel Prado
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile
| | - Agustina Birba
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile,Cognitive Neuroscience Center (CNC), Universidad de San Andrés, Buenos Aires, Argentina,National Scientific and Technical Research Council (CONICET), Buenos Aires, Argentina
| | - Josefina Cruzat
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile
| | - Hernando Santamaría-García
- Pontificia Universidad Javeriana, Medical School, Physiology and Psychiatry Departments, Memory and Cognition Center Intellectus, Hospital Universitario San Ignacio, Bogotá, Colombia
| | - Mario Parra
- School of Psychological Sciences and Health, University of Strathclyde, Glasgow, United Kingdom
| | - Sebastian Moguilner
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile,Cognitive Neuroscience Center (CNC), Universidad de San Andrés, Buenos Aires, Argentina,Global Brain Health Institute (GBHI), University of California San Francisco (UCSF), California, USA,Trinity College Dublin (TCD), Dublin, Ireland
| | - Enzo Tagliazucchi
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile,Departamento de Física, Universidad de Buenos Aires and Instituto de Fisica de Buenos Aires (IFIBA -CONICET), Buenos Aires, Argentina
| | - Agustín Ibáñez
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile,Cognitive Neuroscience Center (CNC), Universidad de San Andrés, Buenos Aires, Argentina,National Scientific and Technical Research Council (CONICET), Buenos Aires, Argentina,Global Brain Health Institute (GBHI), University of California San Francisco (UCSF), California, USA,Trinity College Dublin (TCD), Dublin, Ireland,Corresponding author at: Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago de Chile, Chile., (A. Ibáñez)
| |
Collapse
|
7
|
Fang T, Song Z, Zhan G, Zhang X, Mu W, Wang P, Zhang L, Kang X. Decoding motor imagery tasks using ESI and hybrid feature CNN. J Neural Eng 2022; 19. [DOI: 10.1088/1741-2552/ac4ed0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 01/25/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. BCI based on motor imaging electroencephalogram (MI-EEG) can be useful in a natural interaction system. In this paper, a new framework is proposed to solve the MI-EEG binary classification problem. Approach. Electrophysiological source imaging (ESI) technology is used to solve the influence of volume conduction effect and improve spatial resolution. Continuous wavelet transform (CWT) and best time of interest (TOI) are combined to extract the optimal discriminant spatial-frequency features. Finally, a CNN network with seven convolution layers is used to classify the features. In addition, we also validated several new data augment methods to solve the problem of small data sets and reduce network over-fitting. Main results. The model achieved an average classification accuracy of 93.2% and 95.4% on the BCI Competition III IVa and high-gamma data sets, which is better than most of the published advanced algorithms. By selecting the best TOI for each subject, the classification accuracy rate increased by about 2%. The effects of 4 data augment methods on the classification results were also verified. Among them, the noise addition and overlap methods are better than the other two, and the classification accuracy is improved by at least 4%. On the contrary, the rotation and flip data augment methods reduced the classification accuracy. Significance. Decoding motor imagery tasks can benefited from combing the ESI technology and the data augment technology, which is used to solve the problem of low spatial resolution and small samples of EEG signals, respectively. Based on the results, the model proposed has higher accuracy and application potential in the task of MI-EEG binary classification.
Collapse
|
8
|
Faber PL, Milz P, Reininghaus EZ, Mörkl S, Holl AK, Kapfhammer HP, Pascual-Marqui RD, Kochi K, Achermann P, Painold A. Fundamentally altered global- and microstate EEG characteristics in Huntington's disease. Clin Neurophysiol 2020; 132:13-22. [PMID: 33249251 DOI: 10.1016/j.clinph.2020.10.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 08/25/2020] [Accepted: 10/14/2020] [Indexed: 01/14/2023]
Abstract
OBJECTIVE Huntington's disease (HD) is characterized by psychiatric, cognitive, and motor disturbances. The study aimed to determine electroencephalography (EEG) global state and microstate changes in HD and their relationship with cognitive and behavioral impairments. METHODS EEGs from 20 unmedicated HD patients and 20 controls were compared using global state properties (connectivity and dimensionality) and microstate properties (EEG microstate analysis). For four microstate classes (A, B, C, D), three parameters were computed: duration, occurrence, coverage. Global- and microstate properties were compared between groups and correlated with cognitive test scores for patients. RESULTS Global state analysis showed reduced connectivity in HD and an increasing dimensionality with increasing HD severity. Microstate analysis revealed parameter increases for classes A and B (coverage), decreases for C (occurrence) and D (coverage and occurrence). Disease severity and poorer test performances correlated with parameter increases for class A (coverage and occurrence), decreases for C (coverage and duration) and a dimensionality increase. CONCLUSIONS Global state changes may reflect higher functional dissociation between brain areas and the complex microstate changes possibly the widespread neuronal death and corresponding functional deficits in brain regions associated with HD symptomatology. SIGNIFICANCE Combining global- and microstate analyses can be useful for a better understanding of progressive brain deterioration in HD.
Collapse
Affiliation(s)
- Pascal L Faber
- The KEY Institute for Brain-Mind Research, Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zurich, Switzerland
| | - Patricia Milz
- The KEY Institute for Brain-Mind Research, Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zurich, Switzerland
| | - Eva Z Reininghaus
- Department of Psychiatry and Psychotherapy, Medical University of Graz, Graz, Austria
| | - Sabrina Mörkl
- Department of Psychiatry and Psychotherapy, Medical University of Graz, Graz, Austria
| | - Anna K Holl
- Department of Psychiatry and Psychotherapy, Medical University of Graz, Graz, Austria
| | - Hans-Peter Kapfhammer
- Department of Psychiatry and Psychotherapy, Medical University of Graz, Graz, Austria
| | - Roberto D Pascual-Marqui
- The KEY Institute for Brain-Mind Research, Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zurich, Switzerland
| | - Kieko Kochi
- The KEY Institute for Brain-Mind Research, Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zurich, Switzerland
| | - Peter Achermann
- The KEY Institute for Brain-Mind Research, Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zurich, Switzerland
| | - Annamaria Painold
- Department of Psychiatry and Psychotherapy, Medical University of Graz, Graz, Austria.
| |
Collapse
|
9
|
Demuru M, Kalitzin S, Zweiphenning W, van Blooijs D, Van't Klooster M, Van Eijsden P, Leijten F, Zijlmans M. The value of intra-operative electrographic biomarkers for tailoring during epilepsy surgery: from group-level to patient-level analysis. Sci Rep 2020; 10:14654. [PMID: 32887896 PMCID: PMC7474097 DOI: 10.1038/s41598-020-71359-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 04/23/2020] [Indexed: 01/08/2023] Open
Abstract
Signal analysis biomarkers, in an intra-operative setting, may be complementary tools to guide and tailor the resection in drug-resistant focal epilepsy patients. Effective assessment of biomarker performances are needed to evaluate their clinical usefulness and translation. We defined a realistic ground-truth scenario and compared the effectiveness of different biomarkers alone and combined to localize epileptogenic tissue during surgery. We investigated the performances of univariate, bivariate and multivariate signal biomarkers applied to 1 min inter-ictal intra-operative electrocorticography to discriminate between epileptogenic and non-epileptogenic locations in 47 drug-resistant people with epilepsy (temporal and extra-temporal) who had been seizure-free one year after the operation. The best result using a single biomarker was obtained using the phase-amplitude coupling measure for which the epileptogenic tissue was localized in 17 out of 47 patients. Combining the whole set of biomarkers provided an improvement of the performances: 27 out of 47 patients. Repeating the analysis only on the temporal-lobe resections we detected the epileptogenic tissue in 29 out of 30 combining all the biomarkers. We suggest that the assessment of biomarker performances on a ground-truth scenario is required to have a proper estimate on how biomarkers translate into clinical use. Phase-amplitude coupling seems the best performing single biomarker and combining biomarkers improves localization of epileptogenic tissue. Performance achieved is not adequate as a tool in the operation theater yet, but it can improve the understanding of pathophysiological process.
Collapse
Affiliation(s)
- Matteo Demuru
- Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede, The Netherlands.
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.
| | - Stiliyan Kalitzin
- Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede, The Netherlands
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Willemiek Zweiphenning
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Dorien van Blooijs
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Maryse Van't Klooster
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pieter Van Eijsden
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Frans Leijten
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Maeike Zijlmans
- Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede, The Netherlands
- Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
10
|
Ieracitano C, Mammone N, Hussain A, Morabito FC. A novel multi-modal machine learning based approach for automatic classification of EEG recordings in dementia. Neural Netw 2020; 123:176-190. [DOI: 10.1016/j.neunet.2019.12.006] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 12/03/2019] [Accepted: 12/06/2019] [Indexed: 12/27/2022]
|
11
|
Dong L, Liu X, Zhao L, Lai Y, Gong D, Liu T, Yao D. A Comparative Study of Different EEG Reference Choices for Event-Related Potentials Extracted by Independent Component Analysis. Front Neurosci 2019; 13:1068. [PMID: 31680810 PMCID: PMC6798171 DOI: 10.3389/fnins.2019.01068] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 09/24/2019] [Indexed: 12/16/2022] Open
Abstract
In the event-related potential (ERP) of scalp electroencephalography (EEG) studies, the vertex reference (Cz), linked mastoids or ears (LM), and average reference (AVG) are popular reference methods, and the reference electrode standardization technique (REST) is increasingly applied. Because scalp EEG recordings are considered as spatially degraded signals, independent component analysis (ICA) is a widely used data-driven method for obtaining ERPs by decomposing EEG data. However, the accurate estimation of the differences in ERP components extracted by ICA with different references remains unclear. In this study, we first provided formal descriptions of the above reference methods (Cz, LM, AVG, and REST) and ICA decomposition in ERP and then investigated the influences of different reference techniques on simulation and real EEG datasets. The results revealed that (1) the reference method did not change the peak amplitudes and latencies of relative ERPs corresponding to some IC time courses; (2) there were non-negligible effects of different reference methods on both temporal ERPs and spatial topographies of some ICs; and (3) compared to Cz, LM, and AR, considering both the performances of temporal ERPs and spatial topographies, the REST reference had overall superiority. These findings provide a recommended choice of REST for ICA analysis at the trial level and contribute to empirical investigations regarding the use of reference methods in ERP domains with ICA analysis.
Collapse
Affiliation(s)
- Li Dong
- MOE Key Laboratory for Neuroinformation, The Clinical Hospital of Chengdu Brain Science Institute, University of Electronic Science and Technology of China, Chengdu, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Xiaobo Liu
- School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Lingling Zhao
- School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Yongxiu Lai
- MOE Key Laboratory for Neuroinformation, The Clinical Hospital of Chengdu Brain Science Institute, University of Electronic Science and Technology of China, Chengdu, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Diankun Gong
- MOE Key Laboratory for Neuroinformation, The Clinical Hospital of Chengdu Brain Science Institute, University of Electronic Science and Technology of China, Chengdu, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Tiejun Liu
- MOE Key Laboratory for Neuroinformation, The Clinical Hospital of Chengdu Brain Science Institute, University of Electronic Science and Technology of China, Chengdu, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Dezhong Yao
- MOE Key Laboratory for Neuroinformation, The Clinical Hospital of Chengdu Brain Science Institute, University of Electronic Science and Technology of China, Chengdu, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
12
|
Marzetti L, Basti A, Chella F, D'Andrea A, Syrjälä J, Pizzella V. Brain Functional Connectivity Through Phase Coupling of Neuronal Oscillations: A Perspective From Magnetoencephalography. Front Neurosci 2019; 13:964. [PMID: 31572116 PMCID: PMC6751382 DOI: 10.3389/fnins.2019.00964] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 08/28/2019] [Indexed: 12/01/2022] Open
Abstract
Magnetoencephalography has gained an increasing importance in systems neuroscience thanks to the possibility it offers of unraveling brain networks at time-scales relevant to behavior, i.e., frequencies in the 1-100 Hz range, with sufficient spatial resolution. In the first part of this review, we describe, in a unified mathematical framework, a large set of metrics used to estimate MEG functional connectivity at the same or at different frequencies. The different metrics are presented according to their characteristics: same-frequency or cross-frequency, univariate or multivariate, directed or undirected. We focus on phase coupling metrics given that phase coupling of neuronal oscillations is a putative mechanism for inter-areal communication, and that MEG is an ideal tool to non-invasively detect such coupling. In the second part of this review, we present examples of the use of specific phase methods on real MEG data in the context of resting state, visuospatial attention and working memory. Overall, the results of the studies provide evidence for frequency specific and/or cross-frequency brain circuits which partially overlap with brain networks as identified by hemodynamic-based imaging techniques, such as functional Magnetic Resonance (fMRI). Additionally, the relation of these functional brain circuits to anatomy and to behavior highlights the usefulness of MEG phase coupling in systems neuroscience studies. In conclusion, we believe that the field of MEG functional connectivity has made substantial steps forward in the recent years and is now ready for bringing the study of brain networks to a more mechanistic understanding.
Collapse
Affiliation(s)
- Laura Marzetti
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| | - Alessio Basti
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| | - Federico Chella
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| | - Antea D'Andrea
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| | - Jaakko Syrjälä
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| | - Vittorio Pizzella
- Imaging and Clinical Sciences, Department of Neuroscience, University of Chieti-Pescara, Chieti, Italy
- Institute for Advanced Biomedical Technologies, University of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
13
|
Yao D, Qin Y, Hu S, Dong L, Bringas Vega ML, Valdés Sosa PA. Which Reference Should We Use for EEG and ERP practice? Brain Topogr 2019; 32:530-549. [PMID: 31037477 PMCID: PMC6592976 DOI: 10.1007/s10548-019-00707-x] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 04/02/2019] [Indexed: 11/30/2022]
Abstract
Which reference is appropriate for the scalp ERP and EEG studies? This unsettled problem still inspires unceasing debate. The ideal reference should be the one with zero or constant potential but unfortunately it is well known that no point on the body fulfills this condition. Consequently, more than ten references are used in the present EEG-ERP studies. This diversity seriously undermines the reproducibility and comparability of results across laboratories. A comprehensive review accompanied by a brief communication with rigorous derivations and notable properties (Hu et al. Brain Topogr, 2019. https://doi.org/10.1007/s10548-019-00706-y ) is thus necessary to provide application-oriented principled recommendations. In this paper current popular references are classified into two categories: (1) unipolar references that construct a neutral reference, including both online unipolar references and offline re-references. Examples of unipolar references are the reference electrode standardization technique (REST), average reference (AR), and linked-mastoids/ears reference (LM); (2) non-unipolar references that include the bipolar reference and the Laplacian reference. We show that each reference is derived with a different assumption and serves different aims. We also note from (Hu et al. 2019) that there is a general form for the reference problem, the 'no memory' property of the unipolar references, and a unified estimator for the potentials at infinity termed as the regularized REST (rREST) which has more advantageous statistical evidence than AR. A thorough discussion of the advantages and limitations of references is provided with recommendations in the hope to clarify the role of each reference in the ERP and EEG practice.
Collapse
Affiliation(s)
- Dezhong Yao
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave., West Hi-Tech Zone, Chengdu, 611731, China. .,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China. .,Sichuan Institute for Brain Science and Brain-Inspired Intelligence, Chengdu, China.
| | - Yun Qin
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave., West Hi-Tech Zone, Chengdu, 611731, China.,Sichuan Institute for Brain Science and Brain-Inspired Intelligence, Chengdu, China
| | - Shiang Hu
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave., West Hi-Tech Zone, Chengdu, 611731, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Li Dong
- School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Maria L Bringas Vega
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave., West Hi-Tech Zone, Chengdu, 611731, China.,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China
| | - Pedro A Valdés Sosa
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave., West Hi-Tech Zone, Chengdu, 611731, China. .,School of Life Science and Technology, Center for Information in Medicine, University of Electronic Science and Technology of China, Chengdu, China.
| |
Collapse
|
14
|
|
15
|
Sharma M, Bhurane AA, Rajendra Acharya U. MMSFL-OWFB: A novel class of orthogonal wavelet filters for epileptic seizure detection. Knowl Based Syst 2018. [DOI: 10.1016/j.knosys.2018.07.019] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
16
|
Levin AR, Méndez Leal AS, Gabard-Durnam LJ, O'Leary HM. BEAPP: The Batch Electroencephalography Automated Processing Platform. Front Neurosci 2018; 12:513. [PMID: 30131667 PMCID: PMC6090769 DOI: 10.3389/fnins.2018.00513] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Accepted: 07/10/2018] [Indexed: 12/18/2022] Open
Abstract
Electroencephalography (EEG) offers information about brain function relevant to a variety of neurologic and neuropsychiatric disorders. EEG contains complex, high-temporal-resolution information, and computational assessment maximizes our potential to glean insight from this information. Here we present the Batch EEG Automated Processing Platform (BEAPP), an automated, flexible EEG processing platform incorporating freely available software tools for batch processing of multiple EEG files across multiple processing steps. BEAPP does not prescribe a specified EEG processing pipeline; instead, it allows users to choose from a menu of options for EEG processing, including steps to manage EEG files collected across multiple acquisition setups (e.g., for multisite studies), minimize artifact, segment continuous and/or event-related EEG, and perform basic analyses. Overall, BEAPP aims to streamline batch EEG processing, improve accessibility to computational EEG assessment, and increase reproducibility of results.
Collapse
Affiliation(s)
- April R Levin
- Department of Neurology, Boston Children's Hospital, Boston, MA, United States.,Laboratories of Cognitive Neuroscience, Division of Developmental Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, United States
| | - Adriana S Méndez Leal
- Laboratories of Cognitive Neuroscience, Division of Developmental Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, United States
| | - Laurel J Gabard-Durnam
- Laboratories of Cognitive Neuroscience, Division of Developmental Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, United States
| | - Heather M O'Leary
- Department of Neurology, Boston Children's Hospital, Boston, MA, United States.,Center for Rare Neurological Diseases, Atlanta, GA, United States
| |
Collapse
|
17
|
Hu S, Yao D, Valdes-Sosa PA. Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique). Front Neurosci 2018; 12:297. [PMID: 29780302 PMCID: PMC5946034 DOI: 10.3389/fnins.2018.00297] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2017] [Accepted: 04/17/2018] [Indexed: 12/02/2022] Open
Abstract
The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.
Collapse
Affiliation(s)
- Shiang Hu
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, China
| | - Dezhong Yao
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, China
| | - Pedro A Valdes-Sosa
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, China.,Cuban Neuroscience Center, Havana, Cuba
| |
Collapse
|
18
|
Tian Y, Xu W, Zhang H, Tam KY, Zhang H, Yang L, Li Z, Pang Y. The Scalp Time-Varying Networks of N170: Reference, Latency, and Information Flow. Front Neurosci 2018; 12:250. [PMID: 29720933 PMCID: PMC5915542 DOI: 10.3389/fnins.2018.00250] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Accepted: 04/03/2018] [Indexed: 11/25/2022] Open
Abstract
Using the scalp time-varying network method, the present study is the first to investigate the temporal influence of the reference on N170, a negative event-related potential component (ERP) appeared about 170 ms that is elicited by facial recognition, in the network levels. Two kinds of scalp electroencephalogram (EEG) references, namely, AR (average of all recording channels) and reference electrode standardization technique (REST), were comparatively investigated via the time-varying processing of N170. Results showed that the latency and amplitude of N170 were significantly different between REST and AR, with the former being earlier and smaller. In particular, the information flow from right temporal-parietal P8 to left P7 in the time-varying network was earlier in REST than that in AR, and this phenomenon was reproduced by simulation, in which the performance of REST was closer to the true case at source level. These findings indicate that reference plays a crucial role in ERP data interpretation, and importantly, the newly developed approximate zero-reference REST would be a superior choice for precise evaluation of the scalp spatio-temporal changes relating to various cognitive events.
Collapse
Affiliation(s)
- Yin Tian
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Wei Xu
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Huiling Zhang
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Kin Y Tam
- Faculty of Health Sciences, University of Macau, Taipa, China
| | - Haiyong Zhang
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Li Yang
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Zhangyong Li
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| | - Yu Pang
- Chongqing Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, Chongqing High School Innovation Team of Architecture and Core Technologies of Smart Medical System, Bio-information College, Chongqing University of Posts and Telecommunications, Chongqing, China
| |
Collapse
|
19
|
Wu D. Hearing the Sound in the Brain: Influences of Different EEG References. Front Neurosci 2018; 12:148. [PMID: 29593487 PMCID: PMC5859362 DOI: 10.3389/fnins.2018.00148] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 02/23/2018] [Indexed: 11/13/2022] Open
Abstract
If the scalp potential signals, the electroencephalogram (EEG), are due to neural "singers" in the brain, how could we listen to them with less distortion? One crucial point is that the data recording on the scalp should be faithful and accurate, thus the choice of reference electrode is a vital factor determining the faithfulness of the data. In this study, music on the scalp derived from data in the brain using three different reference electrodes were compared, including approximate zero reference-reference electrode standardization technique (REST), average reference (AR), and linked mastoids reference (LM). The classic music pieces in waveform format were used as simulated sources inside a head model, and they were forward calculated to scalp as standard potential recordings, i.e., waveform format music from the brain with true zero reference. Then these scalp music was re-referenced into REST, AR, and LM based data, and compared with the original forward data (true zero reference). For real data, the EEG recorded in an orthodontic pain control experiment were utilized for music generation with the three references, and the scale free index (SFI) of these music pieces were compared. The results showed that in the simulation for only one source, different references do not change the music/waveform; for two sources or more, REST provide the most faithful music/waveform to the original ones inside the brain, and the distortions caused by AR and LM were spatial locations of both source and scalp electrode dependent. The brainwave music from the real EEG data showed that REST and AR make the differences of SFI between two states more recognized and found the frontal is the main region that producing the music. In conclusion, REST can reconstruct the true signals approximately, and it can be used to help to listen to the true voice of the neural singers in the brain.
Collapse
Affiliation(s)
- Dan Wu
- School of Computer and Information Technology, Beijing Jiaotong University, Beijing, China.,The Key Laboratory for NeuroInformation of Ministry of Education, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
20
|
Li Y, Wang Y, Zhang B, Wang Y, Zhou X. Electrophysiological Responses to Expectancy Violations in Semantic and Gambling Tasks: A Comparison of Different EEG Reference Approaches. Front Neurosci 2018; 12:169. [PMID: 29615858 PMCID: PMC5869192 DOI: 10.3389/fnins.2018.00169] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 03/02/2018] [Indexed: 11/13/2022] Open
Abstract
Dynamically evaluating the outcomes of our actions and thoughts is a fundamental cognitive ability. Given its excellent temporal resolution, the event-related potential (ERP) technology has been used to address this issue. The feedback-related negativity (FRN) component of ERPs has been studied intensively with the averaged linked mastoid reference method (LM). However, it is unknown whether FRN can be induced by an expectancy violation in an antonym relations context and whether LM is the most suitable reference approach. To address these issues, the current research directly compared the ERP components induced by expectancy violations in antonym expectation and gambling tasks with a within-subjects design and investigated the effect of the reference approach on the experimental effects. Specifically, we systematically compared the influence of the LM, reference electrode standardization technique (REST) and average reference (AVE) approaches on the amplitude, scalp distribution and magnitude of ERP effects as a function of expectancy violation type. The expectancy deviation in the antonym expectation task elicited an N400 effect that differed from the FRN effect induced in the gambling task; this difference was confirmed by all the three reference methods. Both the amplitudes of the ERP effects (N400 and FRN) and the magnitude as the expectancy violation increased were greater under the LM approach than those under the REST approach, followed by those under the AVE approach. Based on the statistical results, the electrode sites that showed the N400 and FRN effects critically depended on the reference method, and the results of the REST analysis were consistent with previous ERP studies. Combined with evidence from simulation studies, we suggest that REST is an optional reference method to be used in future ERP data analysis.
Collapse
Affiliation(s)
- Ya Li
- School of Psychology, Shaanxi Normal University, Xi'an, China
| | - Yongchun Wang
- School of Psychology, Shaanxi Normal University, Xi'an, China
| | - Baoqiang Zhang
- School of Psychology, Shaanxi Normal University, Xi'an, China
| | - Yonghui Wang
- School of Psychology, Shaanxi Normal University, Xi'an, China
| | - Xiaolin Zhou
- School of Psychological and Cognitive Sciences, Peking University, Beijing, China.,Beijing Key Laboratory of Behavior and Mental Health, Peking University, Beijing, China.,Key Laboratory of Machine Perception (Ministry of Education), Peking University, Beijing, China.,PKU-IDG/McGovern Institute for Brain Research, Peking University, Beijing, China
| |
Collapse
|
21
|
Hu S, Lai Y, Valdes-Sosa PA, Bringas-Vega ML, Yao D. How do reference montage and electrodes setup affect the measured scalp EEG potentials? J Neural Eng 2018; 15:026013. [PMID: 29368697 DOI: 10.1088/1741-2552/aaa13f] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. APPROACH First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five mono-polar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (linked mastoids (LM), average reference (AR) and reference electrode standardization technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. MAIN RESULTS Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. SIGNIFICANCE These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for cognitive neuroscientists and clinicians.
Collapse
Affiliation(s)
- Shiang Hu
- The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, People's Republic of China
| | | | | | | | | |
Collapse
|
22
|
Abstract
The present study evaluated brain connectivity using electroencephalography (EEG) data from 14 patients with schizophrenia and 14 healthy controls. Phase-Locking Value (PLV), Phase-Lag Index (PLI) and Directed Transfer Function (DTF) were calculated for the original EEG data and following current source density (CSD) transformation, re-referencing using the average reference electrode (AVERAGE) and reference electrode standardization techniques (REST). The statistical analysis of adjacency matrices was carried out using indices based on graph theory. Both CSD and REST reduced the influence of volume conducted currents. The largest group differences in connectivity were observed for the alpha band. Schizophrenic patients showed reduced connectivity strength, as well as a lower clustering coefficient and shorter characteristic path length for both measures of phase synchronization following CSD transformation or REST re-referencing. Reduced synchronization was accompanied by increased directional flow from the occipital region for the alpha band. Following the REST re-referencing, the sources of alpha activity were located at parietal rather than occipital derivations. The results of PLV and DTF demonstrated group differences in fronto-posterior asymmetry following CSD transformation, while for PLI the differences were significant only using REST. The only analysis that identified group differences in inter-hemispheric asymmetry was DTF calculated for REST. Our results suggest that a comparison of different connectivity measures using graph-based indices for each frequency band, separately, may be a useful tool in the study of disconnectivity disorders such as schizophrenia.
Collapse
|
23
|
Graph-based analysis of brain connectivity in schizophrenia. PLoS One 2017; 12:e0188629. [PMID: 29190759 PMCID: PMC5708839 DOI: 10.1371/journal.pone.0188629] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 11/10/2017] [Indexed: 12/18/2022] Open
Abstract
The present study evaluated brain connectivity using electroencephalography (EEG) data from 14 patients with schizophrenia and 14 healthy controls. Phase-Locking Value (PLV), Phase-Lag Index (PLI) and Directed Transfer Function (DTF) were calculated for the original EEG data and following current source density (CSD) transformation, re-referencing using the average reference electrode (AVERAGE) and reference electrode standardization techniques (REST). The statistical analysis of adjacency matrices was carried out using indices based on graph theory. Both CSD and REST reduced the influence of volume conducted currents. The largest group differences in connectivity were observed for the alpha band. Schizophrenic patients showed reduced connectivity strength, as well as a lower clustering coefficient and shorter characteristic path length for both measures of phase synchronization following CSD transformation or REST re-referencing. Reduced synchronization was accompanied by increased directional flow from the occipital region for the alpha band. Following the REST re-referencing, the sources of alpha activity were located at parietal rather than occipital derivations. The results of PLV and DTF demonstrated group differences in fronto-posterior asymmetry following CSD transformation, while for PLI the differences were significant only using REST. The only analysis that identified group differences in inter-hemispheric asymmetry was DTF calculated for REST. Our results suggest that a comparison of different connectivity measures using graph-based indices for each frequency band, separately, may be a useful tool in the study of disconnectivity disorders such as schizophrenia.
Collapse
|
24
|
Dong L, Li F, Liu Q, Wen X, Lai Y, Xu P, Yao D. MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG. Front Neurosci 2017; 11:601. [PMID: 29163006 PMCID: PMC5670162 DOI: 10.3389/fnins.2017.00601] [Citation(s) in RCA: 100] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Accepted: 10/13/2017] [Indexed: 02/02/2023] Open
Abstract
Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero reference is still lacking. Here, we have therefore developed two open-source MATLAB toolboxes for REST of scalp EEG. One version of REST is closely integrated into EEGLAB, which is a popular MATLAB toolbox for processing the EEG data; and another is a batch version to make it more convenient and efficient for experienced users. Both of them are designed to provide an easy-to-use for novice researchers and flexibility for experienced researchers. All versions of the REST toolboxes can be freely downloaded at http://www.neuro.uestc.edu.cn/rest/Down.html, and the detailed information including publications, comments and documents on REST can also be found from this website. An example of usage is given with comparative results of REST and average reference. We hope these user-friendly REST toolboxes could make the relatively novel technique of REST easier to study, especially for applications in various EEG studies.
Collapse
Affiliation(s)
- Li Dong
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Fali Li
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Qiang Liu
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China
| | - Xin Wen
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Yongxiu Lai
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Peng Xu
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Dezhong Yao
- Key Laboratory for NeuroInformation of Ministry of Education, Center for Information in Medicine, High-Field Magnetic Resonance Brain Imaging Key Laboratory of Sichuan Province, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
25
|
Mahajan Y, Peter V, Sharma M. Effect of EEG Referencing Methods on Auditory Mismatch Negativity. Front Neurosci 2017; 11:560. [PMID: 29066945 PMCID: PMC5641332 DOI: 10.3389/fnins.2017.00560] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2017] [Accepted: 09/25/2017] [Indexed: 11/13/2022] Open
Abstract
Auditory event-related potentials (ERPs) have consistently been used in the investigation of auditory and cognitive processing in the research and clinical laboratories. There is currently no consensus on the choice of appropriate reference for auditory ERPs. The most commonly used references in auditory ERP research are the mathematically linked-mastoids (LM) and average referencing (AVG). Since LM and AVG referencing procedures do not solve the issue of electrically-neutral reference, Reference Electrode Standardization Technique (REST) was developed to create a neutral reference for EEG recordings. The aim of the current research is to compare the influence of the reference on amplitude and latency of auditory mismatch negativity (MMN) as a function of magnitude of frequency deviance across three commonly used electrode montages (16, 32, and 64-channel) using REST, LM, and AVG reference procedures. The current study was designed to determine if the three reference methods capture the variation in amplitude and latency of MMN with the deviance magnitude. We recorded MMN from 12 normal hearing young adults in an auditory oddball paradigm with 1,000 Hz pure tone as standard and 1,030, 1,100, and 1,200 Hz as small, medium and large frequency deviants, respectively. The EEG data recorded to these sounds was re-referenced using REST, LM, and AVG methods across 16-, 32-, and 64-channel EEG electrode montages. Results revealed that while the latency of MMN decreased with increment in frequency of deviant sounds, no effect of frequency deviance was present for amplitude of MMN. There was no effect of referencing procedure on the experimental effect tested. The amplitude of MMN was largest when the ERP was computed using LM referencing and the REST referencing produced the largest amplitude of MMN for 64-channel montage. There was no effect of electrode-montage on AVG referencing induced ERPs. Contrary to our predictions, the results suggest that the auditory MMN elicited as a function of increments in frequency deviance does not depend on the choice of referencing procedure. The results also suggest that auditory ERPs generated using REST referencing is contingent on the electrode arrays more than the AVG referencing.
Collapse
Affiliation(s)
- Yatin Mahajan
- The MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Penrith, NSW, Australia.,The HEARing CRC, Melbourne, VIC, Australia
| | - Varghese Peter
- The MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Penrith, NSW, Australia
| | - Mridula Sharma
- The HEARing CRC, Melbourne, VIC, Australia.,Department of Linguistics, Australian Hearing Hub, Macquarie University, Sydney, NSW, Australia
| |
Collapse
|
26
|
Liang T, Hu Z, Li Y, Ye C, Liu Q. Electrophysiological Correlates of Change Detection during Delayed Matching Task: A Comparison of Different References. Front Neurosci 2017; 11:527. [PMID: 29018318 PMCID: PMC5623019 DOI: 10.3389/fnins.2017.00527] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Accepted: 09/11/2017] [Indexed: 11/13/2022] Open
Abstract
Detecting the changed information between memory representation and incoming sensory inputs is a fundamental cognitive ability. By offering the promise of excellent temporal resolution, event-related potential (ERP) technique has served as a primary tool for studying this process with reference of the linked mastoid (LM). However, given that LM may distort the ERP signals, it is still undetermined whether LM is the best reference choice. The goal of the current study was to systematically compare LM, reference electrode standardization technique (REST) and average reference (AR) for assessing the ERP correlates of change detection during a delayed matching task. Colored shapes were adopted as materials while both the task-relevant shape feature and -irrelevant color feature could be changed. The results of the ERP amplitude showed that both of the task-relevant and -conjunction feature changes elicited significantly more positive posterior P2 in REST and AR, but not in LM. Besides, significantly increased N270 was observed in task-relevant and -conjunction feature changes in both the REST and LM, but in the conjunction feature change in AR. Only the REST-obtained N270 revealed a significant increment in task-irrelevant feature change, which was compatible with the delayed behavioral performance. Statistical parametric scalp mapping (SPSM) results showed a left posterior distribution for AR, an anterior distribution for LM, and both the anterior and left posterior distributions for REST. These results indicate that different types of references may provide distinct cognitive interpretations. Interestingly, only the SPSM of REST was consistent with previous fMRI findings. Combined with the evidence of simulation studies and the current observations, we take the REST-based results as the objective one, and recommend using REST technology in the future ERP data analysis.
Collapse
Affiliation(s)
- Tengfei Liang
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China
| | - Zhonghua Hu
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China
| | - Yuchen Li
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China
| | - Chaoxiong Ye
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China.,Department of Psychology, University of Jyväskylä, Jyväskylä, Finland.,Faculty of Information Technology, University of Jyväskylä, Jyväskylä, Finland
| | - Qiang Liu
- Research Center of Brain and Cognitive Neuroscience, Liaoning Normal University, Dalian, China
| |
Collapse
|