1
|
Daich Varela M, Sanders Villa A, Pontikos N, Crossland MD, Michaelides M. Digital health and wearable devices for retinal disease monitoring. Graefes Arch Clin Exp Ophthalmol 2024:10.1007/s00417-024-06634-3. [PMID: 39297890 DOI: 10.1007/s00417-024-06634-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 07/30/2024] [Accepted: 08/29/2024] [Indexed: 09/21/2024] Open
Abstract
Digital health is wielding a growing influence across all areas of healthcare, encompassing various facets such as telemedicine, artificial intelligence (AI), and electronic healthcare records. In Ophthalmology, digital health innovations can be broadly divided into four categories: (i) self-monitoring home devices and apps, (ii) virtual and augmented reality visual aids, (iii) AI software, and (iv) wearables. Wearable devices can work in the background, collecting large amounts of objective data while we do our day-to-day activities, which may be ecologically more valid and meaningful to patients than that acquired in traditional hospital settings. They can be a watch, wristband, piece of clothing, glasses, cane, smartphone in our pocket, earphones, or any other device with a sensor that we carry with us. Focusing on retinal diseases, a key challenge in developing novel therapeutics has been to prove a meaningful benefit in patients' lives and the creation of objective patient-centred endpoints in clinical trials. In this review, we will discuss wearable devices collecting different aspects of visual behaviour, visual field, central vision, and functional vision, as well as their potential implementation as outcome measures in research/clinical trial settings. The healthcare landscape is facing a paradigm shift. Clinicians have a key role of collaborating with the development and fine-tuning of digital health innovations, as well as identifying opportunities where they can be leveraged to enhance our understanding of retinal diseases and improve patient outcomes.
Collapse
Affiliation(s)
- Malena Daich Varela
- Moorfields Eye Hospital, London, UK
- UCL Institute of Ophthalmology, University College London, 11-43 Bath Street, London, EC1V 9EL, UK
| | - Alejandro Sanders Villa
- Facultad de Enfermería y Obstetricia, Universidad Nacional Autónoma de México, Mexico City, México
- Primero Salud, Mexico City, México
| | - Nikolas Pontikos
- Moorfields Eye Hospital, London, UK
- UCL Institute of Ophthalmology, University College London, 11-43 Bath Street, London, EC1V 9EL, UK
| | - Michael D Crossland
- UCL Institute of Ophthalmology, University College London, 11-43 Bath Street, London, EC1V 9EL, UK
| | - Michel Michaelides
- Moorfields Eye Hospital, London, UK.
- UCL Institute of Ophthalmology, University College London, 11-43 Bath Street, London, EC1V 9EL, UK.
| |
Collapse
|
2
|
Hönekopp A, Weigelt S. Using Light Meters to Investigate the Light-Myopia Association - A Literature Review of Devices and Research Methods. Clin Ophthalmol 2023; 17:2737-2760. [PMID: 37743889 PMCID: PMC10517690 DOI: 10.2147/opth.s420631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 08/18/2023] [Indexed: 09/26/2023] Open
Abstract
With the increasing prevalence of myopia, evaluating its relationship with objective light exposure as a potential adjustable environmental factor in myopia development has been an emerging research field in recent years. From a thorough literature search, we identify ten wearable light meters from human studies on light exposure and myopia and present an overview of their parameters, thereby demonstrating the wide between-device variability and discussing its implications. We further identify 20 publications, including two reanalyses, reporting investigations of light-myopia associations with data from human subjects wearing light meters. We thoroughly review the publications with respect to general characteristics, aspects of data collection, participant population, as well as data analysis and interpretation, and also assess potential patterns regarding the absence or presence of light-myopia associations in their results. In doing so, we highlight areas in which more research is needed as well as several aspects that warrant consideration in the study of light exposure and myopia.
Collapse
Affiliation(s)
- Astrid Hönekopp
- Department of Rehabilitation Sciences, Research Unit Vision, Visual Impairments & Blindness, TU Dortmund University, Dortmund, Germany
| | - Sarah Weigelt
- Department of Rehabilitation Sciences, Research Unit Vision, Visual Impairments & Blindness, TU Dortmund University, Dortmund, Germany
| |
Collapse
|
3
|
RaviChandran N, Teo ZL, Ting DSW. Artificial intelligence enabled smart digital eye wearables. Curr Opin Ophthalmol 2023; 34:414-421. [PMID: 37527195 DOI: 10.1097/icu.0000000000000985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/03/2023]
Abstract
PURPOSE OF REVIEW Smart eyewear is a head-worn wearable device that is evolving as the next phase of ubiquitous wearables. Although their applications in healthcare are being explored, they have the potential to revolutionize teleophthalmology care. This review highlights their applications in ophthalmology care and discusses future scope. RECENT FINDINGS Smart eyewear equips advanced sensors, optical displays, and processing capabilities in a wearable form factor. Rapid technological developments and the integration of artificial intelligence are expanding their reach from consumer space to healthcare applications. This review systematically presents their applications in treating and managing eye-related conditions. This includes remote assessments, real-time monitoring, telehealth consultations, and the facilitation of personalized interventions. They also serve as low-vision assistive devices to help visually impaired, and can aid physicians with operational and surgical tasks. SUMMARY Wearables such as smart eyewear collects rich, continuous, objective, individual-specific data, which is difficult to obtain in a clinical setting. By leveraging sophisticated data processing and artificial intelligence based algorithms, these data can identify at-risk patients, recognize behavioral patterns, and make timely interventions. They promise cost-effective and personalized treatment for vision impairments in an effort to mitigate the global burden of eye-related conditions and aging.
Collapse
Affiliation(s)
| | - Zhen Ling Teo
- Singapore National Eye Center, Singapore Eye Research Institute
| | - Daniel S W Ting
- AI and Digital Innovations
- Singapore National Eye Center, Singapore Eye Research Institute
- Duke-NUS Medical School, National University Singapore, Singapore
| |
Collapse
|
4
|
South J, Roberts P, Gao T, Black J, Collins A. Development of a Spectacle Wear Monitor System: SpecsOn Monitor. Transl Vis Sci Technol 2021; 10:11. [PMID: 34614165 PMCID: PMC8496409 DOI: 10.1167/tvst.10.12.11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Purpose This study aimed to custom design, build, and test a removable device that accurately and objectively monitors adherence to spectacle wear in preschool children participating in clinical trials. This work will provide researchers with the tools to investigate the effect of adherence to optical treatment in conditions relating to refractive error, such as anisometropia, amblyopia, myopia, and accommodative esotropia, where spectacle wearing behaviors are of interest. Methods Several sensors were considered in the design of the SpecsOn monitor. The final version included two temperature sensors, one that measures skin temperature through an infrared sensor directed at the wearer's temple on the spectacle arm and the other measuring device temperature. The difference between the two temperature readings is used to determine if the spectacles were worn. The SpecsOn monitor was tested in two phases in adult participants (laboratory n = 10 and real world n = 5). Results Results from both phases showed good agreement between the objective measurement of wear based on skin and device temperature differences and participants’ manually logged wear times. The custom built SpecsOn monitor was 99% successful in accurately detecting spectacle wear in our adult cohort. Conclusions The SpecsOn monitor offers a convenient, accurate, and reliable system to monitor spectacle adherence. The devices were comfortable, secure, and unobtrusive to wear, and fitted easily to a variety of frame styles. Translational Relevance Easy access to spectacle compliance information from the SpecsOn monitor during the optical treatment phase will optimize visual outcomes and provide detailed clinical data to support decision making on the need and timing of additional therapies, improving treatment efficiency.
Collapse
Affiliation(s)
- Jayshree South
- School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand
| | - Paul Roberts
- Medlink Innovation Limited, Auckland, New Zealand, Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Tina Gao
- School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand
| | - Joanna Black
- School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand
| | - Andrew Collins
- School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
5
|
Barcala X, Vinas M, Romero M, Gambra E, Mendez-Gonzalez JL, Marcos S, Dorronsoro C. Multifocal acceptance score to evaluate vision: MAS-2EV. Sci Rep 2021; 11:1397. [PMID: 33446794 PMCID: PMC7809428 DOI: 10.1038/s41598-021-81059-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 01/04/2021] [Indexed: 11/30/2022] Open
Abstract
We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through different binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modified monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantified using different metrics: overall visual quality, visual degradation at far, visual benefit at near, near stereo benefit, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufficient repeatability and sensitivity to allow differentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo benefit. 46.67% of the subjects ranked binocular bifocal corrections first, and 46.67% of the subjects ranked monovision first. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens fitting or intraocular lens implantation.
Collapse
Affiliation(s)
| | - Maria Vinas
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Mercedes Romero
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | | | | | - Susana Marcos
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain
| |
Collapse
|
6
|
Abstract
This Editorial presents a new Special Issue dedicated to some old and new interdisciplinary areas of cooperation between engineering and surgery. The first two sections offer some food for thought, in terms of a brief introductory and general review of the past, present, future and visionary perspectives of the synergy between engineering and surgery. The last section presents a very short and reasoned review of the contributions that have been included in the present Special Issue. Given the vastness of the topic that this Special Issue deals with, we hope that our effort may have offered a stimulus, albeit small, to the development of cooperation between engineering and surgery.
Collapse
|