1
|
Negm EE, Patel M, Ryan P. Impact of the superimposition reference area on intraoral scanning accuracy in a partially dentate maxilla. J Prosthet Dent 2024; 132:189.e1-189.e11. [PMID: 38556406 DOI: 10.1016/j.prosdent.2024.03.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/14/2024] [Accepted: 03/14/2024] [Indexed: 04/02/2024]
Abstract
STATEMENT OF PROBLEM The alignment of 3-dimensional (3D) files involves selecting a reference area before performing a local best fit alignment during the digital scan superimposition and is essential for comparing digital scans. Scan alignment relies on both reference area location and the alignment algorithm. However, a consensus on the impact of different reference areas on intraoral scanning accuracy is lacking. PURPOSE The purpose of this in vitro study was to assess the impact of 3 superimposition reference areas on the accuracy of 3 intraoral scanners for a partially dentate maxilla. MATERIAL AND METHODS A Kennedy class II resin cast was scanned using 3 intraoral scanners (Primescan, TRIOS 3, and Emerald) outputting 30 digital scans (10 per scanner). Test scans from intraoral scanners were subsequently compared with a reference digital standard tessellation language file generated by a laboratory scanner with validated accuracy. The files were superimposed using best fit alignment for each intraoral scanner using 3 different superimposition reference areas (whole region of interest, palate, and all teeth). Accuracy was assessed by using a 3D analysis program (Geomagic Control X; 3D systems) for each scanner at 4 preselected areas. Test and reference scan differences were depicted on color maps and quantified via root mean square deviations. Differences were analyzed using regression analysis with the post hoc student t test and Bonferroni correction (α=.05). RESULTS The TRIOS 3 and Emerald produced positive deviations in the palatal color maps, whereas Primescan produced more uniform color maps, regardless of the superimposition strategy used. Primescan exhibited the best accuracy (trueness and precision) in both palatal and bounded edentulous areas, regardless of the superimposition reference area. The TRIOS 3 recorded the highest distal extension trueness (ranging from 42.9±7.7 µm to 65 ±19.5 µm), and Primescan achieved the highest precision (ranging from 28.5 ±9.8 µm to 48.9 ±16.9 µm), regardless of the superimposition area. Emerald demonstrated the highest teeth trueness (ranging from 31.6 ±6.8 µm to 69.6 ±11.5 µm), while Primescan produced the highest precision (ranging from 17.9 ±6.1 µm to 30.7 ±9.2 µm), regardless of the reference area used. CONCLUSIONS The chosen reference area for best fit alignment significantly influenced digital scan accuracy (P<.001). Primescan displayed the highest palatal and bounded edentulous area accuracy, with TRIOS 3 recording the highest distal extension trueness. Emerald recorded the highest teeth trueness and Primescan recorded the highest distal extension and tooth precision. All conclusions were independent of the superimposition strategy used.
Collapse
Affiliation(s)
- Enas Elhamy Negm
- PhD student, Centre for Oral Bioengineering, Institute of Dentistry, Queen Mary University of London, London, England, United Kingdom; Assistant Lecturer, Department of Prosthodontics, Faculty of Dentistry, Tanta University, Tanta, Egypt.
| | - Mangala Patel
- Professor, Dental Biomaterials, Centre for Oral Bioengineering, Institute of Dentistry, Queen Mary University of London, London, England, UK
| | - Paul Ryan
- Clinical Senior Lecturer, Restorative Dentistry and Periodontology, Centre for Oral Immunobiology and Regenerative Medicine, Institute of Dentistry, Queen Mary University of London, London, England, UK
| |
Collapse
|
2
|
Jiang Y, Long H, Soo SY, Mavani H, Tew IM. Accuracy of Complete-Arch Scans Obtained by Intraoral Scanner and Smartphone Three-Dimensional Scanning Applications With Different Smartphone Position Setups: An In Vitro Study. Cureus 2024; 16:e63471. [PMID: 39077296 PMCID: PMC11286105 DOI: 10.7759/cureus.63471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/29/2024] [Indexed: 07/31/2024] Open
Abstract
INTRODUCTION The high cost of intraoral scanners (IOS) for complete-arch scans makes them less accessible for many dental practitioners. As a viable alternative, smartphone scanner applications (SMP) provide comparable scanning capabilities at a significantly low cost. However, there is limited data on the accuracy of SMP, especially when used in various smartphone positions. This study aimed to compare the three-dimensional (3D) and linear accuracy of complete-arch scans acquired by an IOS and SMP (KIRI Engine, KIRI Innovations, Guangdong, China) at three shooting angles (0°, 45°, and 90° for SMP_3A) and two shooting angles (30° and 60° for SMP_2A). METHODS A stone dental cast was scanned with a laboratory scanner as a reference, with 11 scans performed by an IOS, SMP_2A, and SMP_3A. In 3D analysis, trueness and precision were evaluated through superimposition with the reference scan and within each group, respectively, using the best-fit algorithm of Geomagic Wrap software (3D Systems, Inc., Rock Hill, SC). Trueness in linear discrepancy was assessed by comparing the occlusal-cervical and mesiodistal dimensions of reference teeth (canine, premolar, and molar), intercanine width, and intermolar width on the digital casts to measurements of the stone cast, while precision was measured using the coefficient of variance. Differences between groups were analyzed using the Friedman test, followed by the Dunn-Bonferroni post hoc test with a significance level set at 0.05. RESULTS IOS exhibited significantly lower trueness than SMP_2A (p = 0.003) with significantly greater width discrepancies on canines (p = 0.001) and molars (p < 0.001). Discrepancy patterns differed among the three scanning methods. The IOS showed greater discrepancies on the occlusal surfaces of posterior teeth. While SMP_3A demonstrated higher variation on the palatal surfaces and interproximal areas of posterior teeth. For precision, SMP_3A (p = 0.028) and SMP_2A (p = 0.003) showed a significantly lower precision in 3D analysis, but a comparable reproducibility in linear measurement to IOS. CONCLUSION TRIOS IOS (3Shape, Copenhagen, Denmark) exhibited lower trueness in 3D and linear accuracy analyses for complete-arch scans. The positions of the smartphone significantly enhanced trueness at the undercut region. SMP_2A and SMP_3A can be a potential alternative for precise linear measurement in complete-arch scans with selective use.
Collapse
Affiliation(s)
- Yuhao Jiang
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - Hu Long
- Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, CHN
| | - Suet Yeo Soo
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - Hetal Mavani
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - In Meei Tew
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| |
Collapse
|
3
|
Donmez MB, Güven ME, Yılmaz D, Abou-Ayash S, Çakmak G, Yilmaz B. Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body. J Dent 2023; 139:104716. [PMID: 37739057 DOI: 10.1016/j.jdent.2023.104716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 08/23/2023] [Accepted: 09/19/2023] [Indexed: 09/24/2023] Open
Abstract
OBJECTIVES To evaluate the accuracy of the scans of the combined healing abutment-scan body (CHA-SB) system located at different sites of the maxilla when SBs are replaced in between each scan. METHODS Three SBs were seated into HAs located at the central incisor, first premolar, and first molar sites of a maxillary model inside a phantom head, and the model was scanned extraorally (CEREC Primescan SW 5.2). This procedure was repeated with new SBs until a total of 10 scans were performed. Standard tessellation language files of CHA-SBs at each implant location were isolated, transferred into analysis software (Geomagic Control X), and superimposed over the proprietary library files to analyze surface (root mean square), linear, and angular deviations. Trueness and precision were evaluated with one-way analysis of variance and Tukey tests. The correlation between surface and angular deviations was analyzed with Pearson's correlation (α=0.05). RESULTS Molar implant scans had the highest surface and angular deviations (P≤.006), while central incisor implant scans had higher precision (surface deviations) than premolar implant scans (P=.041). Premolar implant scans had higher accuracy than central incisor implant scans on the y-axis (P≤.029). Central incisor implant scans had the highest accuracy on the z-axis (P≤.018). A strong positive correlation was observed between surface and angular deviations (r = 0.864, P<.001). CONCLUSION Central incisor implant scans mostly had high accuracy and molar implant scans mostly had lower trueness. SBs were mostly positioned apically; however, the effect of SB replacement can be considered small as measured deviations were similar to those in previous studies and the precision of scans was high. CLINICAL SIGNIFICANCE Repositioning of scan bodies into healing abutments would be expected to result in similar single crown positioning regardless of the location of the implant, considering high scan precision with the healing abutment-scan body system. The duration of the chairside adjustments of crowns in the posterior maxilla may be longer than those in the anterior region.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Mehmet Esad Güven
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Deniz Yılmaz
- Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Ohio, United States of America
| |
Collapse
|
4
|
Hardan L, Bourgi R, Lukomska-Szymanska M, Hernández-Cabanillas JC, Zamarripa-Calderón JE, Jorquera G, Ghishan S, Cuevas-Suárez CE. Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies. J Adv Prosthodont 2023; 15:315-332. [PMID: 38205120 PMCID: PMC10774636 DOI: 10.4047/jap.2023.15.6.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 11/28/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024] Open
Abstract
PURPOSE This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, Strasbourg, France
| | | | - Juan Carlos Hernández-Cabanillas
- Health Sciences Faculty, Autonomous University of Baja California, Blvd Universitario 1000 Valle de Las Palmas, Tijuana, B.C. Mexico
| | - Juan Eliezer Zamarripa-Calderón
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| | - Gilbert Jorquera
- Department of Prosthodontics, Universidad de los Andes, Santiago, Chile
| | | | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| |
Collapse
|
5
|
Donmez MB, Mathey A, Gäumann F, Mathey A, Yilmaz B, Abou-Ayash S. Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: An in vitro study. Clin Implant Dent Relat Res 2023. [PMID: 36762495 DOI: 10.1111/cid.13190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/05/2023] [Accepted: 01/27/2023] [Indexed: 02/11/2023]
Abstract
BACKGROUND Accuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported fixed partial denture (FPD) in different partially edentulous situations when digitized by using different IOSs. PURPOSE To investigate the effect of IOS and FPD situation on the scan accuracy of two implants when partial-arch scans were performed. MATERIALS AND METHODS Tissue level implants were placed in 3 maxillary models with implant spaces either at right first premolar and right first molar sites (Model 1, 3-unit FPD), at right canine and right first molar sites (Model 2, 4-unit FPD), or at lateral incisor sites (Model 3, 4-unit FPD). Reference standard tessellation language (STL) files of the models were generated by using an optical scanner (ATOS Capsule 200MV120). Two IOSs (CEREC Primescan [CP] and TRIOS 3 [TR]) were used to perform partial-arch scans (test-scans) of each model (n = 14), which were exported in STL format. A metrology-grade analysis software (GOM Inspect 2018) was used to superimpose test-scan STLs over the reference STL to calculate 3D distance, inter-implant distance, and angular (mesiodistal and buccopalatal) deviations. Trueness and precision analyses were performed by using bootstrap analysis of variance followed by Welch tests with Holm correction (α = 0.05). RESULTS Trueness of the scans was affected by IOS and FPD situation when 3D distance deviations were considered, while inter-implant distance, mesiodistal angular, and buccopalatal angular deviations were only affected by the FPD situation (p < 0.001). Scan precision was affected by the interaction between the IOSs and the FPD situation when 3D distance and buccopalatal angular deviations were concerned, while IOSs and FPD situation were effective when all deviations were concerned (p≤ 0.001). When 3D distance deviations were considered, CP scans had higher accuracy TR scans in Models 1 and 3 (p ≤ 0.002), and the Model 1 scans had the highest accuracy (p < 0.001). When inter-implant distance deviations were considered, Model 1 scans had the highest accuracy with CP and higher accuracy than Model 2 when TR was used (p ≤ 0.030). When mesiodistal angular deviations were considered, Model 1 scans had the highest accuracy (p ≤ 0.040). When buccopalatal angular deviations were considered, Model 1 scans had the highest accuracy among models when CP was used (p ≤ 0.020). CONCLUSIONS Posterior 3-unit fixed partial denture implant scans, CP scans, and combination of these two factors had accuracy either similar to or better than their tested counterparts.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ayse Mathey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Fabio Gäumann
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Amber Mathey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations. J Dent 2022; 127:104358. [PMID: 36356837 DOI: 10.1016/j.jdent.2022.104358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/03/2022] [Accepted: 11/05/2022] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES To compare the accuracy and time efficiency of different digital workflows in 3 implant-supported fixed partial denture situations. METHODS Three partially edentulous maxillary models with 2 implants (Model 1: implants at lateral incisor sites; Model 2: implants at right canine and first molar sites; Model 3: implants at right first premolar and first molar sites) were digitized (ATOS Capsule 200MV120, n=1) for reference scans. Test scans were performed for direct (Primescan (DDW-P) and Trios 3 (DDW-T)) and indirect (IDW) digital workflows (n=14). For IDW, stone casts (type IV) were obtained from vinylsiloxanether impressions and digitized (S600 Arti). The scan/impression and post processing times were recorded. Reference and test scans were superimposed (GOM Inspect) to calculate 3D point, inter-implant distance, and angular deviations. Kruskal-Wallis and Mann-Whitney tests were used for trueness and precision analyses (α=.05). RESULTS Tested workflows affected trueness (P≤.030) and precision (P<.001) of scans (3D point, inter-implant distance, and angular deviations) within models. DDW-P had the highest accuracy (3D point deviations) for models 1 and 3 (P≤.046). IDW had the lowest accuracy for model 2 (P<.01). DDW-P had the highest accuracy (inter-implant distance deviations) for model 3 (P≤.048). Direct digital workflow mostly led to lower angular deviations (P≤.040), and higher precision for models 2 (mesiodistal direction) and 3 (P<.001). The time for direct digital workflow was shorter (P<.001), DDW-P being more efficient than DDW-T (P=.008). CONCLUSION Direct digital workflow was more accurate and efficient than indirect digital workflow in tested partial edentulism situations with 2 implants. CLINICAL SIGNIFICANCE Tested intraoral scanners can be recommended for accurate and efficient impressions of anterior and posterior 3- or 4-unit implant-supported fixed partial dentures.
Collapse
|