1
|
Echeverri E, Skjöldebrand C, O'Callaghan P, Palmquist A, Kreuger J, Hulsart-Billström G, Persson C. Fe and C additions decrease the dissolution rate of silicon nitride coatings and are compatible with microglial viability in 3D collagen hydrogels. Biomater Sci 2023; 11:3144-3158. [PMID: 36919682 DOI: 10.1039/d2bm02074b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
Silicon nitride (SiN) coatings may reduce unwanted release of metal ions from metallic implants. However, as SiN slowly dissolves in aqueous solutions, additives that reduce this dissolution rate would likely increase the lifetime and functionality of implants. Adding iron (Fe) and carbon (C) permits tuning of the SiN coatings' mechanical properties, but their effect on SiN dissolution rates, and their capacity to reduce metal ion release from metallic implant substrates, have yet to be investigated. Such coatings have recently been proposed for use in spinal implants; therefore, it is relevant to assess their impact on the viability of cells expected at the implant site, such as microglia, the resident macrophages of the central nervous system (CNS). To study the effects of Fe and C on the dissolution rate of SiN coatings, compositional gradients of Si, Fe and C in combination with N were generated by physical vapor deposition onto CoCrMo discs. Differences in composition did not affect the surface roughness or the release of Si, Fe or Co ions (the latter from the CoCrMo substrate). Adding Fe and C reduced ion release compared to a SiN reference coating, which was attributed to altered reactivity due to an increase in the fraction of stabilizing Si-C or Fe-C bonds. Extracts from the SiN coatings containing Fe and C were compatible with microglial viability in 2D cultures and 3D collagen hydrogels, to a similar degree as CoCrMo and SiN coated CoCrMo reference extracts. As Fe and C reduced the dissolution rate of SiN-coatings and did not compromise microglial viability, the capacity of these additives to extend the lifetime and functionality of SiN-coated metallic implants warrants further investigation.
Collapse
Affiliation(s)
- Estefanía Echeverri
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Charlotte Skjöldebrand
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Paul O'Callaghan
- Department of Medical Cell Biology, Science for Life Laboratory, Uppsala University, Sweden
| | | | - Johan Kreuger
- Department of Medical Cell Biology, Science for Life Laboratory, Uppsala University, Sweden
| | - Gry Hulsart-Billström
- Translational PET Imaging, Department of Medicinal Chemistry, Uppsala University, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| |
Collapse
|
2
|
Skjöldebrand C, Tipper JL, Hatto P, Bryant M, Hall RM, Persson C. Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants. Mater Today Bio 2022; 15:100270. [PMID: 35601891 PMCID: PMC9118168 DOI: 10.1016/j.mtbio.2022.100270] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/09/2022] [Accepted: 04/24/2022] [Indexed: 10/29/2022] Open
Abstract
Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in modular components, can cause hypersensitivity and local tissue necrosis, while particles originating from a polymer component have been associated with aseptic loosening and osteolysis. Implant coatings have the potential to improve properties compared to both bulk metal and ceramic alternatives. Ceramic coatings have the potential to increase scratch resistance, enhance wettability and reduce wear of the articulating surfaces compared to the metallic substrate, whilst maintaining overall toughness of the implant ensuring a lower risk of catastrophic failure of the device compared to use of a bulk ceramic. Coatings can also act as barriers to inhibit ion release from the underlying material caused by corrosion. This review aims to provide a comprehensive overview of wear-resistant coatings for joint replacements - both those that are in current clinical use as well as those under investigation for future use. While the majority of coatings belong predominantly in the latter group, a few coated implants have been successfully marketed and are available for clinical use in specific applications. Commercially available coatings for implants include titanium nitride (TiN), titanium niobium nitride (TiNbN), oxidized zirconium (OxZr) and zirconium nitride (ZrN) based coatings, whereas current research is focused not only on these, but also on diamond-like-carbon (DLC), silicon nitride (SiN), chromium nitride (CrN) and tantalum-based coatings (TaN and TaO). The coating materials referred to above that are still at the research stage have been shown to be non-cytotoxic and to reduce wear in a laboratory setting. However, the adhesion of implant coatings remains a main area of concern, as poor adhesion can cause delamination and excessive wear. In clinical applications zirconium implant surfaces treated to achieve a zirconium oxide film and TiNbN coated implants have however been proven comparable to traditional cobalt chromium implants with regards to revision numbers. In addition, the chromium ion levels measured in the plasma of patients were lower and allergy symptoms were relieved. Therefore, coated implants could be considered an alternative to uncoated metal implants, in particular for patients with metal hypersensitivity. There have also been unsuccessful introductions to the market, such as DLC coated implants, and therefore this review also attempts to summarize the lessons learnt.
Collapse
Affiliation(s)
| | - Joanne L. Tipper
- University of Technology Sydney, School of Biomedical Engineering, Sydney, Australia
| | | | - Michael Bryant
- University of Leeds, Department of Mechanical Engineering, Leeds, United Kingdom
| | - Richard M. Hall
- University of Leeds, Department of Mechanical Engineering, Leeds, United Kingdom
| | - Cecilia Persson
- Uppsala University, Department of Materials Science and Engineering, Uppsala, Sweden
| |
Collapse
|
3
|
Skjöldebrand C, Echeverri E, Hulsart-Billström G, Persson C. Tailoring the dissolution rate and in vitro cell response of silicon nitride coatings through combinatorial sputtering with chromium and niobium. Biomater Sci 2022; 10:3757-3769. [PMID: 35622079 DOI: 10.1039/d1bm01978c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Ceramic coatings have been widely investigated as a means to reduce wear and metallic ion release from joint implants. Silicon nitride-based coatings have been a topic of interest specifically due to their solubility in aqueous solutions. This could imply a reduced adverse immune response since the generated debris would dissolve. However, there are concerns regarding the dissolution rate and adhesion of these silicon nitride-based coatings. This study attempts to address the concern of dissolution rate as well as coating adhesion of silicon nitride coatings. We hypothesized that alloying with chromium and niobium would affect the adhesion, dissolution rate, and the resulting ion release and cell response to the coatings. A combinatorial approach was used to deposit sputtered coatings with compositional gradients both with and without a CrN interlayer. Compositional gradients were achieved for all the investigated elements: Si (38.6-46.9 at%), Nb (2.2-4.6 at%) and Cr (1.9-6.0 at%). However, while the presence of an interlayer reduced the delamination during adhesion testing, the differences in composition in the top coating did not affect the adhesion. Nor did the top coating's composition affect the surface roughness or the coatings' inherent mechanical properties (elastic modulus and hardness). All coating compositions were associated with a low Co release from the underlying metal and points with a higher Cr content (4.3-6.0 at%) gave an overall lower release of Si, Cr and Nb ions, possibly due to the formation of a stable oxide, which reduced the dissolution rate of the coating. Optimum chromium contents were furthermore found to give an enhanced in vitro fibroblast cell viability. In conclusion, the results indicate a possibility to tailor the ion release rate, which lends promise to further investigations such as tribocorrosive tests towards a future biomedical application.
Collapse
Affiliation(s)
- Charlotte Skjöldebrand
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Estefanía Echeverri
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Gry Hulsart-Billström
- Translational Imaging, Department of Medicinal Chemistry, Uppsala University, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| |
Collapse
|
4
|
Tsai CE, Hung J, Hu Y, Wang DY, Pilliar RM, Wang R. Improving fretting corrosion resistance of CoCrMo alloy with TiSiN and ZrN coatings for orthopedic applications. J Mech Behav Biomed Mater 2020; 114:104233. [PMID: 33302168 DOI: 10.1016/j.jmbbm.2020.104233] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 11/17/2020] [Accepted: 11/25/2020] [Indexed: 10/22/2022]
Abstract
Total hip replacement is the most effective treatment for late stage osteoarthritis. However, adverse local tissue reactions (ALTRs) have been observed in patients with modular total hip implants. Although the detailed mechanisms of ALTRs are still unknown, fretting corrosion and the associated metal ion release from the CoCrMo femoral head at the modular junction has been reported to be a major factor. The purpose of this study is to increase the fretting corrosion resistance of the CoCrMo alloy and the associated metal ion release by applying hard coatings to the surface. Cathodic arc evaporation technique (arc-PVD) was used to deposit TiSiN and ZrN hard coatings on CoCrMo substrates. The morphology, chemical composition, crystal structures and residual stress of the coatings were characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffractometry. Hardness, elastic modulus, and adhesion of the coatings were measured by nano-indentation, nano-scratch test, and the Rockwell C test. Fretting corrosion resistance tests of coated and uncoated CoCrMo discs against Ti6Al4V spheres were conducted on a four-station fretting testing machine in simulated body fluid at 1Hz for 1 million cycles. Post-fretting samples were analyzed for morphological changes, volume loss and metal ion release. Our analyses showed better surface finish and lower residual stress for ZrN coating, but higher hardness and better scratch resistance for TiSiN coating. Fretting results demonstrated substantial improvement in fretting corrosion resistance of CoCrMo with both coatings. ZrN and TiSiN decreased fretting volume loss by more than 10 times and 1000 times, respectively. Both coatings showed close to 90% decrease of Co ion release during fretting corrosion tests. Our results suggest that hard coating deposition on CoCrMo alloy can significantly improve its fretting corrosion resistance and could thus potentially alleviate ALTRs in metal hip implants.
Collapse
Affiliation(s)
- Chen-En Tsai
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - James Hung
- Aurora Scientific Corp., Richmond BC, Canada
| | - Youxin Hu
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | | | - Robert M Pilliar
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada; Centre for Hip Health and Mobility, Vancouver, BC, Canada.
| |
Collapse
|
5
|
Haschke H, Falkenberg A, Morlock MM, Huber G. Do SiNx coatings bear the potential to reduce the risk of micromotion in modular taper junctions? Proc Inst Mech Eng H 2020; 234:897-908. [PMID: 32507037 DOI: 10.1177/0954411920930616] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Fretting corrosion is one contributor to the clinical failure of modular joint arthroplasty. It is initiated by micromotion in metal junctions exposed to fluids. Omitting metal-on-metal contacts could help to reduce the corrosion risk. The coating of one metal taper partner with a ceramic-based silicon nitride (SiNx) coating might provide this separation. The aim of the study was to identify whether a SiNx coating of the male taper component influences the micromotion within a taper junction. Hip prosthesis heads made of CoCr29Mo6 (Aesculap) and Ti6Al4V (Peter Brehm) were assembled (2000 N) to SiNx-coated and uncoated stem tapers made of Ti6Al4V and CoCr29Mo6 (2×2×2 combinations, each n = 4). Consecutive sinusoidal loading representing three daily activities was applied. Contactless relative motion in six degrees of freedom was measured using six eddy-current sensors. Micromotion in the junction was determined by compensating for the elastic deformation derived from additional monoblock measurements. After pull-off, the taper surfaces were microscopically inspected. Micromotion magnitude reached up to 8.4 ± 0.8 µm during loading that represented stumbling. Ti6Al4V stems showed significantly higher micromotion than those made of CoCr29Mo6, while taper coating had no influence. Statistical differences in pull-off forces were found for none of the taper junctions. Microscopy revealed CoCr29Mo6 abrasion from the head taper surface if combined with coated stem tapers. Higher micromotion of Ti6Al4V tapers was probably caused by the lower Young's modulus. Even in the contact areas, the coating was not damaged during loading. The mechanics of coated tapers was similar to uncoated prostheses. Thus, the separation of the two metal surfaces with the objective to reduce in vivo corrosion appears to be achievable if the coating is able to withstand in vivo conditions. However, the hard ceramic-based stem coating lead to undesirable debris from the CoCr29Mo6 heads during loading.
Collapse
Affiliation(s)
- Henning Haschke
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Adrian Falkenberg
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| | - Gerd Huber
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
| |
Collapse
|
6
|
Skjöldebrand C, Hulsart-Billström G, Engqvist H, Persson C. Si-Fe-C-N Coatings for Biomedical Applications: A Combinatorial Approach. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2074. [PMID: 32366008 PMCID: PMC7254256 DOI: 10.3390/ma13092074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 04/15/2020] [Accepted: 04/23/2020] [Indexed: 11/17/2022]
Abstract
Ceramic coatings may prolong the lifetime of joint implants. Certain ions and wear debris may however lead to negative biological effects. SiN-based materials may substantially reduce these effects, but still need optimization for the application. In this study, a combinatorial deposition method enabled an efficient evaluation of a range of Si-Fe-C-N coating compositions on the same sample. The results revealed compositional gradients of Si (26.0-33.9 at.%), Fe (9.6-20.9 at.%), C (8.2-13.9 at.%) and N (39.7-47.2 at.%), and low oxygen contaminations (0.3-0.6 at.%). The mechanical properties varied with a hardness (H) ranging between 13.7-17.3 GPa and an indentation modulus (M) between 190-212 GPa. Both H and M correlated with the Si (H and M increased as Si increased) and Fe (H and M decreased as Fe increased) content. A slightly columnar morphology was observed in cross-sections, as well as a surface roughness in the nm range. A cell study revealed adhering pre-osteogenic MC3T3 cells, with a morphology similar to that of cells seeded on a tissue culture plastic control. The investigated coatings could be considered for further investigation due to the ability to tune their mechanical properties while maintaining a smooth surface, together with their promising in vitro cell response.
Collapse
Affiliation(s)
- Charlotte Skjöldebrand
- Department of Materials Science and Engineering, Faculty of Science and Technology, Uppsala University, 752 37 Uppsala, Sweden; (C.S.); (H.E.)
| | - Gry Hulsart-Billström
- Department of Surgical Sciences, Faculty of Medicine and Pharmacy, Uppsala University, 751 83 Uppsala, Sweden;
| | - Håkan Engqvist
- Department of Materials Science and Engineering, Faculty of Science and Technology, Uppsala University, 752 37 Uppsala, Sweden; (C.S.); (H.E.)
| | - Cecilia Persson
- Department of Materials Science and Engineering, Faculty of Science and Technology, Uppsala University, 752 37 Uppsala, Sweden; (C.S.); (H.E.)
| |
Collapse
|
7
|
The Effect of N, C, Cr, and Nb Content on Silicon Nitride Coatings for Joint Applications. MATERIALS 2020; 13:ma13081896. [PMID: 32316517 PMCID: PMC7216083 DOI: 10.3390/ma13081896] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/12/2020] [Accepted: 04/14/2020] [Indexed: 12/23/2022]
Abstract
Ceramic coatings deposited on orthopedic implants are an alternative to achieve and maintain high wear resistance of the metallic device, and simultaneously allow for a reduction in metal ion release. Silicon nitride based (SiNx) coatings deposited by high power impulse magnetron sputtering (HiPIMS) have shown potential for use in joint replacements, as a result of an improved chemical stability in combination with a good adhesion. This study investigated the effect of N, C, Cr, and Nb content on the tribocorrosive performance of 3.7 to 8.8 µm thick SiNx coatings deposited by HiPIMS onto CoCrMo discs. The coating composition was assessed from X-ray photoelectron spectroscopy and the surface roughness by vertical scanning interferometry. Hardness and Young's modulus were measured by nanoindentation and coating adhesion was investigated by scratch tests. Multidirectional wear tests against ultrahigh molecular weight polyethylene pins were performed for 2 million cycles in bovine serum solution (25%) at 37 °C, at an estimated contact pressure of 2.1 MPa. Coatings with a relatively low hardness tended to fail earlier in the wear test, due to chemical reactions and eventually dissolution, accelerated by the tribological contact. In fact, while no definite correlation could be observed between coating composition (N: 42.6-55.5 at %, C: 0-25.7 at %, Cr: 0 or 12.8 at %, and Nb: 0-24.5 at %) and wear performance, it was apparent that high-purity and/or -density coatings (i.e., low oxygen content and high nitrogen content) were desirable to prevent coating and/or counter surface wear or failure. Coatings deposited with a higher energy fulfilled the target profile in terms of low surface roughness (Ra < 20 nm), adequate adhesion (Lc2 > 30 N), chemical stability over time in the tribocorrosive environment, as well as low polymer wear, presenting potential for a future application in joint bearings.
Collapse
|
8
|
Khatami Z, Simpson PJ, Mascher P. Process-dependent mechanical and optical properties of nanostructured silicon carbonitride thin films. NANOTECHNOLOGY 2019; 30:314003. [PMID: 30970339 DOI: 10.1088/1361-6528/ab180c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Amorphous hydrogenated silicon carbonitride (a-SiCN:H) thin films were grown using electron cyclotron resonance chemical vapour deposition using a mixture of methane, nitrogen, and silane as precursors. The origin of the variation of macroscopic properties such as hardness (H), elastic modulus (E), photoluminescence (PL), and the optical band gap was investigated through their correlation with the microscopic features of a-SiCN:H thin films as a function of the process parameters, including the deposition temperature and methane gas flow rate. From a microstructural perspective, the thin films were investigated using x-ray photoelectron spectroscopy, Rutherford backscattering spectrometry, elastic recoil detection, transmission electron microscopy, and x-ray diffraction. It is verified that an increase of the substrate temperature resulted in the substitution of hydrogen atoms mainly by carbon atoms, causing the density of the silicon carbide-related structures to increase in the amorphous structure of the a-SiCN:H thin films. Hardness and elastic modulus were found to increase with the deposition temperature and decreased with an increase of the methane gas flow during the deposition, resulting in higher carbon content in the films. The observed changes are ascribed to the reduced density of the weak hydrogen terminated bonds and the variation of the relative bond density of Si-C to Si-N bonds. In addition, the thin films were depth profiled using a slow positron beam to investigate the role of vacancies. The observed increase of the positronium formation with increasing deposition temperature was found to correlate with the variation of PL, where an enhancement of the visible emission originating from carbon-related defects was observed. A set of optimized process parameters to fabricate a-SiCN:H thin films with improved visible emission and hardness properties is suggested.
Collapse
Affiliation(s)
- Zahra Khatami
- Department of Engineering Physics and Centre for Emerging Device Technologies, McMaster University, Hamilton, Ontario, L8S 4L7, Canada. Department of Physics, University of New Brunswick, Fredericton, New Brunswick, E3B 5A3, Canada
| | | | | |
Collapse
|
9
|
Material Structure and Mechanical Properties of Silicon Nitride and Silicon Oxynitride Thin Films Deposited by Plasma Enhanced Chemical Vapor Deposition. SURFACES 2018. [DOI: 10.3390/surfaces1010006] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Silicon nitride and silicon oxynitride thin films are widely used in microelectronic fabrication and microelectromechanical systems (MEMS). Their mechanical properties are important for MEMS structures; however, these properties are rarely reported, particularly the fracture toughness of these films. In this study, silicon nitride and silicon oxynitride thin films were deposited by plasma enhanced chemical vapor deposition (PECVD) under different silane flow rates. The silicon nitride films consisted of mixed amorphous and crystalline Si3N4 phases under the range of silane flow rates investigated in the current study, while the crystallinity increased with silane flow rate in the silicon oxynitride films. The Young’s modulus and hardness of silicon nitride films decreased with increasing silane flow rate. However, for silicon oxynitride films, Young’s modulus decreased slightly with increasing silane flow rate, and the hardness increased considerably due to the formation of a crystalline silicon nitride phase at the high flow rate. Overall, the hardness, Young modulus, and fracture toughness of the silicon nitride films were greater than the ones of silicon oxynitride films, and the main reason lies with the phase composition: the SiNx films were composed of a crystalline Si3N4 phase, while the SiOxNy films were dominated by amorphous Si–O phases. Based on the overall mechanical properties, PECVD silicon nitride films are preferred for structural applications in MEMS devices.
Collapse
|