1
|
Yeob J, Hong SW, Koh WG, Park I. Enhanced Mechanical and Thermal Properties of Polyimide Films Using Hydrophobic Fumed Silica Fillers. Polymers (Basel) 2024; 16:297. [PMID: 38276705 PMCID: PMC10820428 DOI: 10.3390/polym16020297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/16/2024] [Accepted: 01/18/2024] [Indexed: 01/27/2024] Open
Abstract
Polyimide (PI) composite films with enhanced mechanical properties were prepared by incorporating modified fumed silica (FS) particles while preserving their optical and thermal characteristics. The PI matrix was synthesized using a fluorinated diamine, a fluorinated dianhydride, and a rigid biphenyl dianhydride via chemical imidization. Commercially available FS particles, including unmodified FS particles (0-FS) and particles modified with dimethyl (2-FS), trimethyl (3-FS), octyl (8-FS), octamethylcyclotetrasiloxane (D4-FS), and polydimethylsiloxane (PDMS-FS) were used. Scanning electron microscope images and nitrogen adsorption-desorption isotherms revealed well-defined porous structures in the FS particles. The water contact angles on the composite films increased compared to those of the pristine PI films, indicating improved water resistance. The PI/0-FS films exhibited a typical trade-off relationship between tensile modulus and elongation at break, as observed in conventional composites. Owing to the poor compatibility and agglomeration of the PDMS-FS particles, the PI/PDMS-FS composite films exhibited poor mechanical performance and diminished optical characteristics. Although the longer-chained FS particles (8- and D4-FS) improved the tensile modulus of the PI film by up to 12%, a reduction of more than 20% in toughness was observed. The PI composite films containing the methylated FS particles (2- and 3-FS) outperformed 8- and D4-FS in terms of mechanical properties, with PI/3-FS films showing an over 10% increased tensile modulus (from 4.07 to 4.42 GPa) and 15% improved toughness (from 6.97 to 8.04 MJ/m3) at 7 wt. % silica loading. Except for the PI/PDMS-FS composites, all composite film samples exhibited more than 86% transmittance at 550 nm. Regarding thermal properties, the glass transition temperature (Tg) and thermal stability remained stable for most composite films. In addition, PI/3-FS films demonstrated enhanced dimensional stability with lower coefficients of thermal expansion (from 47.3 to 34.5 ppm/°C). Overall, this study highlights the potential of incorporating specific modified FS particles to tailor the mechanical, optical, and thermal properties of PI composite films.
Collapse
Affiliation(s)
- Jongin Yeob
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea;
- Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology (KITECH), 89 Yangdaegiro-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si 31056, Republic of Korea;
| | - Sung Woo Hong
- Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology (KITECH), 89 Yangdaegiro-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si 31056, Republic of Korea;
| | - Won-Gun Koh
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea;
| | - In Park
- Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology (KITECH), 89 Yangdaegiro-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si 31056, Republic of Korea;
- KITECH School, University of Science and Technology (UST), 176 Gajeong-dong, Yuseong-gu, Daejeon 34113, Republic of Korea
| |
Collapse
|
2
|
Al-Sulaimi S, Kushwah R, Abdullah Alsibani M, El Jery A, Aldrdery M, Ashraf GA. Emerging Developments in Separation Techniques and Analysis of Chiral Pharmaceuticals. Molecules 2023; 28:6175. [PMID: 37687004 PMCID: PMC10489017 DOI: 10.3390/molecules28176175] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/05/2023] [Accepted: 08/14/2023] [Indexed: 09/10/2023] Open
Abstract
Chiral separation, the process of isolating enantiomers from a racemic mixture, holds paramount importance in diverse scientific disciplines. Using chiral separation methods like chromatography and electrophoresis, enantiomers can be isolated and characterized. This study emphasizes the significance of chiral separation in drug development, quality control, environmental analysis, and chemical synthesis, facilitating improved therapeutic outcomes, regulatory compliance, and enhanced industrial processes. Capillary electrophoresis (CE) has emerged as a powerful technique for the analysis of chiral drugs. This review also highlights the significance of CE in chiral drug analysis, emphasizing its high separation efficiency, rapid analysis times, and compatibility with other detection techniques. High-performance liquid chromatography (HPLC) has become a vital technique for chiral drugs analysis. Through the utilization of a chiral stationary phase, HPLC separates enantiomers based on their differential interactions, allowing for the quantification of individual enantiomeric concentrations. This study also emphasizes the significance of HPLC in chiral drug analysis, highlighting its excellent resolution, sensitivity, and applicability. The resolution and enantiomeric analysis of nonsteroidal anti-inflammatory drugs (NSAIDs) hold great importance due to their chiral nature and potential variations in pharmacological effects. Several studies have emphasized the significance of resolving and analyzing the enantiomers of NSAIDs. Enantiomeric analysis provides critical insights into the pharmacokinetics, pharmacodynamics, and potential interactions of NSAIDs, aiding in drug design, optimization, and personalized medicine for improved therapeutic outcomes and patient safety. Microfluidics systems have revolutionized chiral separation, offering miniaturization, precise fluid control, and high throughput. Integration of microscale channels and techniques provides a promising platform for on-chip chiral analysis in pharmaceuticals and analytical chemistry. Their applications in techniques such as high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) offer improved resolution and faster analysis times, making them valuable tools for enantiomeric analysis in pharmaceutical, environmental, and biomedical research.
Collapse
Affiliation(s)
- Sulaiman Al-Sulaimi
- Department of Biological Science and Chemistry, University of Nizwa, Nizwa 611, Oman; (S.A.-S.); (R.K.); (M.A.A.)
| | - Reveka Kushwah
- Department of Biological Science and Chemistry, University of Nizwa, Nizwa 611, Oman; (S.A.-S.); (R.K.); (M.A.A.)
| | - Mohammed Abdullah Alsibani
- Department of Biological Science and Chemistry, University of Nizwa, Nizwa 611, Oman; (S.A.-S.); (R.K.); (M.A.A.)
| | - Atef El Jery
- Department of Chemical Engineering, College of Engineering, King Khalid University, Abha 61411, Saudi Arabia
| | - Moutaz Aldrdery
- Department of Chemical Engineering, College of Engineering, King Khalid University, Abha 61411, Saudi Arabia
| | | |
Collapse
|
3
|
Aydoğan C, Beltekin B, Alharthi S, Ağca CA, Erdoğan İY. Nano-liquid chromatography with monolithic stationary phase based on naphthyl monomer for proteomics analysis. J Chromatogr A 2023; 1690:463804. [PMID: 36689803 DOI: 10.1016/j.chroma.2023.463804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/11/2023] [Accepted: 01/15/2023] [Indexed: 01/18/2023]
Abstract
Monolithic poly(2-vinylnaphthalene-co-divinylbenzene) columns were introduced, for the first time, and were evaluated as the separation media for nano-liquid chromatography (nano-LC). These columns were prepared by in-situ polymerization of 2-vinylnaphthalene (2-VNA) as the functional monomer and divinylbenzene (DVB) as the crosslinker in a fused silica capillary column of 50 µm i.d. Various porogenic solvents, including tetrahydrofuran (THF), dodecanol and toluene were used for morphology optimization. Final monolithic column (referred to as VNA column) was characterized by using scanning electron microscopy (SEM) and chromatographic analyses. Alkylbenzenes (ABs), and polyaromatic hydrocarbons (PAHs) were separated using the VNA column while the column offered excellent hydrophobic and π-π interactions under reversed-phase conditions. Theoretical plates number up to 41,200 plates/m in isocratic mode for ethylbenzene could be achieved. The potential of the final VNA column was demonstrated with a gradient elution in the separation of six intact proteins, including ribonuclease A (RNase A), cytochrome C (Cyt C), lysozyme (Lys), β-lactoglobulin (β-lac), myoglobin (My) and α-chymotrypsinogen (α-chym) in nano LC system. The column was then applied to the peptide analysis of trypsin digested cytochrome C, allowing a high peak capacity up to 1440 and the further proteomics analysis of COS-7 cell line was attempted applying the final monolithic column in nano-LC UV system.
Collapse
Affiliation(s)
- Cemil Aydoğan
- Food Analysis and Research Laboratory, Bingöl University, Bingöl, Türkiye; Department of Food Engineering, Bingöl University, Bingöl, Türkiye; Department of Chemistry, Bingöl University, Bingöl, Türkiye.
| | - Büşra Beltekin
- Food Analysis and Research Laboratory, Bingöl University, Bingöl, Türkiye
| | - Sarah Alharthi
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif, 21944 Saudi Arabia
| | - Can Ali Ağca
- Department of Molecular Biology, Bingöl University, Bingöl, Türkiye
| | - İbrahim Y Erdoğan
- Department of Chemistry, Bingöl University, Bingöl, Türkiye; Faculty of Health Sciences, Bingöl University, Bingöl, Türkiye
| |
Collapse
|
4
|
Nano-Liquid Chromatography with a New Monolithic Column for the Analysis of Coenzyme Q10 in Pistachio Samples. Molecules 2023; 28:molecules28031423. [PMID: 36771088 PMCID: PMC9920066 DOI: 10.3390/molecules28031423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/28/2023] [Accepted: 01/29/2023] [Indexed: 02/05/2023] Open
Abstract
Coenzyme Q10 (CoQ10) is a vital substance found throughout body. It helps convert food into energy and is eaten small amounts in foods. CoQ10 has gained great interest in recent years as a potential candidate for the treatment of various diseases. The content of CoQ10 in food samples is a crucial quality index for foods. Therefore, the development of sensitive separation and quantification method for determining the amount of CoQ10 in various samples, especially in foods, is an important issue, especially for food nutrition. In this study, a new, miniaturized monolithic column was developed and applied for the determination of CoQ10 in pistachio samples by nano-liquid chromatography (nano-LC). The monolithic column with a 50 µm i.d. was prepared by in situ polymerization using laurylmethacrylate (LMA) as the main monomer and ethylene dimethacrylate (EDMA) as the crosslinker. Methanol (MeOH) and polyethyleneglycol (PEG) were used as porogenic solvents. The final monolithic column was characterized by using scanning electron microscopy (SEM) and chromatographic analyses. The monolithic column with a 50 µm i.d. was applied to the analysis of CoQ10 in pistachio samples in nano-LC. This analytical method was validated by means of sensitivity, linearity, precision, recovery, and repeatability. The LOD and LOQ values were 0.05 and 0.48 µg/kg, respectively. The developed method using the monolithic column was optimized to achieve very sensitive analyses of CoQ10 content in the food samples. The applicability of the method was successfully demonstrated by the analysis of CoQ10 in pistachio samples.
Collapse
|
5
|
Beltekin B, Alharthi S, Aydoğan C. Novel open‐tubular columns with highly hydrophobic stationary phase for peptide and protein separation by nano‐liquid chromatography. SEPARATION SCIENCE PLUS 2023. [DOI: 10.1002/sscp.202200111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Büşra Beltekin
- Food Analysis and Research Laboratory Bingöl University Bingöl Türkiye
| | - Sarah Alharthi
- Department of Chemistry, College of Science Taif University Taif Saudi Arabia
| | - Cemil Aydoğan
- Food Analysis and Research Laboratory Bingöl University Bingöl Türkiye
- Department of Chemistry Bingöl University Bingöl Türkiye
- Department of Food Engineering Bingöl University Bingöl Türkiye
| |
Collapse
|
6
|
Liang Y, Zhang L, Zhang Y. Chromatographic separation of peptides and proteins for characterization of proteomes. Chem Commun (Camb) 2023; 59:270-281. [PMID: 36504223 DOI: 10.1039/d2cc05568f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Characterization of proteomes aims to comprehensively characterize proteins in cells or tissues via two main strategies: (1) bottom-up strategy based on the separation and identification of enzymatic peptides; (2) top-down strategy based on the separation and identification of intact proteins. However, it is challenged by the high complexity of proteomes. Consequently, the improvements in peptide and protein separation technologies for simplifying the sample should be critical. In this feature article, separation columns for peptide and protein separation were introduced, and peptide separation technologies for bottom-up proteomic analysis as well as protein separation technologies for top-down proteomic analysis were summarized. The achievement, recent development, limitation and future trends are discussed. Besides, the outlook on challenges and future directions of chromatographic separation in the field of proteomics was also presented.
Collapse
Affiliation(s)
- Yu Liang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| | - Lihua Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| | - Yukui Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| |
Collapse
|