1
|
Dien J. Multi-Algorithm Artifact Correction (MAAC) procedure part one: Algorithm and example. Biol Psychol 2024; 188:108775. [PMID: 38499226 DOI: 10.1016/j.biopsycho.2024.108775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/10/2024] [Accepted: 03/14/2024] [Indexed: 03/20/2024]
Abstract
The Multi-Algorithm Artifact Correction (MAAC) procedure is presented for electroencephalographic (EEG) data, as made freely available in the open-source EP Toolkit (Dien, 2010). First the major EEG artifact correction methods (regression, spatial filters, principal components analysis, and independent components analysis) are reviewed. Contrary to the dominant approach of picking one method that is thought to be most effective, this review concludes that none are globally superior, but rather each has strengths and weaknesses. Then each of the major artifact types are reviewed (Blink, Corneo-Retinal Dipole, Saccadic Spike Potential, and Movement). For each one, it is proposed that one of the major correction methods is best matched to address it, resulting in the MAAC procedure. The MAAC itself is then presented, as implemented in the EP Toolkit, in order to provide a sense of the user experience. The primary goal of this present paper is to make the conceptual argument for the MAAC approach.
Collapse
Affiliation(s)
- Joseph Dien
- Department of Human Development and Quantitative Methodology, University of Maryland, 3304 Benjamin Building, College Park, MD 20742, USA.
| |
Collapse
|
2
|
Irrera F, Gumiero A, Zampogna A, Boscari F, Avogaro A, Gazzanti Pugliese di Cotrone MA, Patera M, Della Torre L, Picozzi N, Suppa A. Multisensor Integrated Platform Based on MEMS Charge Variation Sensing Technology for Biopotential Acquisition. SENSORS (BASEL, SWITZERLAND) 2024; 24:1554. [PMID: 38475089 DOI: 10.3390/s24051554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/25/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024]
Abstract
We propose a new methodology for long-term biopotential recording based on an MEMS multisensor integrated platform featuring a commercial electrostatic charge-transfer sensor. This family of sensors was originally intended for presence tracking in the automotive industry, so the existing setup was engineered for the acquisition of electrocardiograms, electroencephalograms, electrooculograms, and electromyography, designing a dedicated front-end and writing proper firmware for the specific application. Systematic tests on controls and nocturnal acquisitions from patients in a domestic environment will be discussed in detail. The excellent results indicate that this technology can provide a low-power, unexplored solution to biopotential acquisition. The technological breakthrough is in that it enables adding this type of functionality to existing MEMS boards at near-zero additional power consumption. For these reasons, it opens up additional possibilities for wearable sensors and strengthens the role of MEMS technology in medical wearables for the long-term synchronous acquisition of a wide range of signals.
Collapse
Affiliation(s)
- Fernanda Irrera
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00185 Rome, Italy
| | | | - Alessandro Zampogna
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
| | | | - Angelo Avogaro
- Department of Medicine, University of Padua, 35122 Padua, Italy
| | | | - Martina Patera
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
| | | | | | - Antonio Suppa
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
- IRCCS Neuromed, 86077 Pozzilli, Italy
| |
Collapse
|
3
|
Liu Z, Wang L, Xu S, Lu K. A multiwavelet-based sparse time-varying autoregressive modeling for motor imagery EEG classification. Comput Biol Med 2023; 155:106196. [PMID: 36842221 DOI: 10.1016/j.compbiomed.2022.106196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/25/2022] [Accepted: 10/09/2022] [Indexed: 11/22/2022]
Abstract
Brain-computer Interface (BCI) system based on motor imagery (MI) heavily relies on electroencephalography (EEG) recognition with high accuracy. However, modeling and classification of MI EEG signals remains a challenging task due to the non-linear and non-stationary characteristics of the signals. In this paper, a new time-varying modeling framework combining multiwavelet basis functions and regularized orthogonal forward regression (ROFR) algorithm is proposed for the characterization and classification of MI EEG signals. Firstly, the time-varying coefficients of the time-varying autoregressive (TVAR) model are precisely approximated with the multiwavelet basis functions. Then a powerful ROFR algorithm is employed to dramatically alleviate the redundant model structure and accurately recover the relevant time-varying model parameters to obtain high resolution power spectral density (PSD) features. Finally, the features are sent to different classifiers for the classification task. To effectively improve the accuracy of classification, a principal component analysis (PCA) algorithm is utilized to determine the best feature subset and Bayesian optimization algorithm is performed to obtain the optimal parameters of the classifier. The proposed method achieves satisfactory classification accuracy on the public BCI Competition II Dataset III, which proves that this method potentially improves the recognition accuracy of MI EEG signals, and has great significance for the construction of BCI system based on MI.
Collapse
Affiliation(s)
- Zhenfei Liu
- National Key Laboratory of Science and Technology on Aerospace Intelligence Control, Beijing Aerospace Automatic Control Institute, Beijing, 100854, China.
| | - Lina Wang
- National Key Laboratory of Science and Technology on Aerospace Intelligence Control, Beijing Aerospace Automatic Control Institute, Beijing, 100854, China.
| | - Song Xu
- National Key Laboratory of Science and Technology on Aerospace Intelligence Control, Beijing Aerospace Automatic Control Institute, Beijing, 100854, China.
| | - Kunfeng Lu
- National Key Laboratory of Science and Technology on Aerospace Intelligence Control, Beijing Aerospace Automatic Control Institute, Beijing, 100854, China.
| |
Collapse
|
4
|
Rizzo M, Petrini L, Del Percio C, Lopez S, Arendt‐Nielsen L, Babiloni C. Mirror visual feedback during unilateral finger movements is related to the desynchronization of cortical electroencephalographic somatomotor alpha rhythms. Psychophysiology 2022; 59:e14116. [PMID: 35657095 PMCID: PMC9788070 DOI: 10.1111/psyp.14116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 04/21/2022] [Accepted: 05/04/2022] [Indexed: 12/30/2022]
Abstract
Using a mirror adequately oriented, the motion of just one hand induces the illusion of the movement with the other hand. Here, we tested the hypothesis that such a mirror phenomenon may be underpinned by an electroencephalographic (EEG) event-related desynchronization/synchronization (ERD/ERS) of central alpha rhythms (around 10 Hz) as a neurophysiological measure of the interactions among cerebral cortex, basal ganglia, and thalamus during movement preparation and execution. Eighteen healthy right-handed male participants performed standard auditory-triggered unilateral (right) or bilateral finger movements in the No Mirror (M-) conditions. In the Mirror (M+) condition, the unilateral right finger movements were performed in front of a mirror oriented to induce the illusion of simultaneous left finger movements. EEG activity was recorded from 64 scalp electrodes, and the artifact-free event-related EEG epochs were used to compute alpha ERD. In the M- conditions, a bilateral prominent central alpha ERD was observed during the bilateral movements, while left central alpha ERD and right alpha ERS were seen during unilateral right movements. In contrast, the M+ condition showed significant bilateral and widespread alpha ERD during the unilateral right movements. These results suggest that the above illusion of the left movements may be related to alpha ERD measures reflecting excitatory desynchronizing signals in right lateral premotor and primary somatomotor areas possibly in relation to basal ganglia-thalamic loops.
Collapse
Affiliation(s)
- Marco Rizzo
- Center for Neuroplasticity and Pain (CNAP), SMIDepartment of Health Science and TechnologyAalborg UniversityAalborgDenmark
| | - Laura Petrini
- Center for Neuroplasticity and Pain (CNAP), SMIDepartment of Health Science and TechnologyAalborg UniversityAalborgDenmark
| | - Claudio Del Percio
- Department of Physiology and Pharmacology “V. Erspamer”Sapienza University of RomeRomeItaly
| | - Susanna Lopez
- Department of Physiology and Pharmacology “V. Erspamer”Sapienza University of RomeRomeItaly
| | - Lars Arendt‐Nielsen
- Center for Neuroplasticity and Pain (CNAP), SMIDepartment of Health Science and TechnologyAalborg UniversityAalborgDenmark,Department of Medical Gastroenterology, Mech‐SenseAalborg University HospitalAalborgDenmark
| | - Claudio Babiloni
- Department of Physiology and Pharmacology “V. Erspamer”Sapienza University of RomeRomeItaly
| |
Collapse
|
5
|
Wang H, Yua H, Wang H. EEG_GENet: A feature-level graph embedding method for motor imagery classification based on EEG signals. Biocybern Biomed Eng 2022. [DOI: 10.1016/j.bbe.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
6
|
Prasad DS, Chanamallu SR, Prasad KS. Optimized deformable convolution network for detection and mitigation of ocular artifacts from EEG signal. MULTIMEDIA TOOLS AND APPLICATIONS 2022; 81:30841-30879. [PMID: 35431612 PMCID: PMC8989407 DOI: 10.1007/s11042-022-12874-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 02/08/2022] [Accepted: 03/10/2022] [Indexed: 06/14/2023]
Abstract
Electroencephalogram (EEG) is the key component in the field of analyzing brain activity and behavior. EEG signals are affected by artifacts in the recorded electrical activity; thereby it affects the analysis of EGG. To extract the clean data from EEG signals and to improve the efficiency of detection during encephalogram recordings, a developed model is required. Although various methods have been proposed for the artifacts removal process, sill the research on this process continues. Even if, several types of artifacts from both the subject and equipment interferences are highly contaminated the EEG signals, the most common and important type of interferences is known as Ocular artifacts. Many applications like Brain-Computer Interface (BCI) need online and real-time processing of EEG signals. Hence, it is best if the removal of artifacts is performed in an online fashion. The main intention of this proposal is to accomplish the new deep learning-based ocular artifacts detection and prevention model. In the detection phase, the 5-level Discrete Wavelet Transform (DWT), and Pisarenko harmonic decomposition are used for decomposing the signals. Then, the Principle Component Analysis (PCA) and Independent Component Analysis (ICA) are adopted as the techniques for extracting the features. With the collected features, the development of optimized Deformable Convolutional Networks (DCN) is used for the detection of ocular artifacts from the input EEG signal. Here, the optimized DCN is developed by optimizing or tuning some significant parameters by Distance Sorted-Electric Fish Optimization (DS-EFO). If the artifacts are detected, the mitigation process is performed by applying the Empirical Mean Curve Decomposition (EMCD), and then, the optimized DCN is used for denoising the signals. Finally, the clean signal is generated by applying inverse EMCD. Based on the EEG data collected from diverse subjects, the proposed method has achieved a higher performance than that of conventional methods, which demonstrates a better ocular-artifact reduction by the proposed method.
Collapse
Affiliation(s)
| | | | - Kodati Satya Prasad
- Department of ECE, JNTUK, University College of Engineering, Kakinada, AP India
| |
Collapse
|
7
|
Manoni A, Gumiero A, Zampogna A, Ciarlo C, Panetta L, Suppa A, Della Torre L, Irrera F. Long-Term Polygraphic Monitoring through MEMS and Charge Transfer for Low-Power Wearable Applications. SENSORS (BASEL, SWITZERLAND) 2022; 22:2566. [PMID: 35408181 PMCID: PMC9002930 DOI: 10.3390/s22072566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/14/2022] [Accepted: 03/22/2022] [Indexed: 02/01/2023]
Abstract
In this work, we propose a wireless wearable system for the acquisition of multiple biopotentials through charge transfer electrostatic sensors realized in MEMS technology. The system is designed for low power consumption and low invasiveness, and thus candidates for long-time monitoring in free-living conditions, with data recording on an SD or wireless transmission to an external elaborator. Thanks to the wide horizon of applications, research is very active in this field, and in the last few years, some devices have been introduced on the market. The main problem with those devices is that their operation is time-limited, so they do not match the growing demand for long monitoring, which is a must-have feature in diagnosing specific diseases. Furthermore, their versatility is hampered by the fact that they have been designed to record just one type of signal. Using ST-Qvar sensors, we acquired an electrocardiogram trace and single-channel scalp electroencephalogram from the frontal lobes, together with an electrooculogram. Excellent results from all three types of acquisition tests were obtained. The power consumption is very low, demonstrating that, thanks to the MEMS technology, a continuous acquisition is feasible for several days.
Collapse
Affiliation(s)
- Alessandro Manoni
- Department of Information Engineering, Electronics, and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy; (C.C.); (L.P.); (F.I.)
| | | | - Alessandro Zampogna
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy; (A.Z.); (A.S.)
| | - Chiara Ciarlo
- Department of Information Engineering, Electronics, and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy; (C.C.); (L.P.); (F.I.)
| | - Lorenzo Panetta
- Department of Information Engineering, Electronics, and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy; (C.C.); (L.P.); (F.I.)
| | - Antonio Suppa
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy; (A.Z.); (A.S.)
- IRCCS Neuromed, 86077 Pozzilli, Italy
| | | | - Fernanda Irrera
- Department of Information Engineering, Electronics, and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy; (C.C.); (L.P.); (F.I.)
| |
Collapse
|
8
|
Zhao M, Bonassi G, Guarnieri R, Pelosin E, Nieuwboer A, Avanzino L, Mantini D. A multi-step blind source separation approach for the attenuation of artifacts in mobile high-density electroencephalography data. J Neural Eng 2021; 18. [PMID: 34874319 DOI: 10.1088/1741-2552/ac4084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 12/06/2021] [Indexed: 11/12/2022]
Abstract
Objective.Electroencephalography (EEG) is a widely used technique to address research questions about brain functioning, from controlled laboratorial conditions to naturalistic environments. However, EEG data are affected by biological (e.g. ocular, myogenic) and non-biological (e.g. movement-related) artifacts, which-depending on their extent-may limit the interpretability of the study results. Blind source separation (BSS) approaches have demonstrated to be particularly promising for the attenuation of artifacts in high-density EEG (hdEEG) data. Previous EEG artifact removal studies suggested that it may not be optimal to use the same BSS method for different kinds of artifacts.Approach.In this study, we developed a novel multi-step BSS approach to optimize the attenuation of ocular, movement-related and myogenic artifacts from hdEEG data. For validation purposes, we used hdEEG data collected in a group of healthy participants in standing, slow-walking and fast-walking conditions. During part of the experiment, a series of tone bursts were used to evoke auditory responses. We quantified event-related potentials (ERPs) using hdEEG signals collected during an auditory stimulation, as well as the event-related desynchronization (ERD) by contrasting hdEEG signals collected in walking and standing conditions, without auditory stimulation. We compared the results obtained in terms of auditory ERP and motor-related ERD using the proposed multi-step BSS approach, with respect to two classically used single-step BSS approaches.Main results. The use of our approach yielded the lowest residual noise in the hdEEG data, and permitted to retrieve stronger and more reliable modulations of neural activity than alternative solutions. Overall, our study confirmed that the performance of BSS-based artifact removal can be improved by using specific BSS methods and parameters for different kinds of artifacts.Significance.Our technological solution supports a wider use of hdEEG-based source imaging in movement and rehabilitation studies, and contributes to the further development of mobile brain/body imaging applications.
Collapse
Affiliation(s)
- Mingqi Zhao
- Research Center for Motor Control and Neuroplasticity, KU Leuven, 3001 Leuven, Belgium
| | - Gaia Bonassi
- S.C. Medicina Fisica e Riabilitazione Ospedaliera, Azienda Sanitaria Locale Chiavarese, 16043 Chiavari, Italy
| | - Roberto Guarnieri
- Research Center for Motor Control and Neuroplasticity, KU Leuven, 3001 Leuven, Belgium.,Icometrix, 3012 Leuven, Belgium
| | - Elisa Pelosin
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics and Maternal Child Health, University of Genova, 16132 Genova, Italy.,Ospedale Policlinico San Martino, IRCCS, 16132 Genoa, Italy
| | - Alice Nieuwboer
- Department of Rehabilitation Sciences, KU Leuven, 3001 Leuven, Belgium
| | - Laura Avanzino
- Ospedale Policlinico San Martino, IRCCS, 16132 Genoa, Italy.,Department of Experimental Medicine, Section of Human Physiology, University of Genoa, 16132 Genoa, Italy
| | - Dante Mantini
- Research Center for Motor Control and Neuroplasticity, KU Leuven, 3001 Leuven, Belgium.,Brain Imaging and Neural Dynamics Research Group, IRCCS San Camillo Hospital, 30126 Venice, Italy
| |
Collapse
|
9
|
Teng CL, Zhang YY, Wang W, Luo YY, Wang G, Xu J. A Novel Method Based on Combination of Independent Component Analysis and Ensemble Empirical Mode Decomposition for Removing Electrooculogram Artifacts From Multichannel Electroencephalogram Signals. Front Neurosci 2021; 15:729403. [PMID: 34707475 PMCID: PMC8542780 DOI: 10.3389/fnins.2021.729403] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/01/2021] [Indexed: 12/03/2022] Open
Abstract
Electrooculogram (EOG) is one of common artifacts in recorded electroencephalogram (EEG) signals. Many existing methods including independent component analysis (ICA) and wavelet transform were applied to eliminate EOG artifacts but ignored the possible impact of the nature of EEG signal. Therefore, the removal of EOG artifacts still faces a major challenge in EEG research. In this paper, the ensemble empirical mode decomposition (EEMD) and ICA algorithms were combined to propose a novel EEMD-based ICA method (EICA) for removing EOG artifacts from multichannel EEG signals. First, the ICA method was used to decompose original EEG signals into multiple independent components (ICs), and the EOG-related ICs were automatically identified through the kurtosis method. Then, by performing the EEMD algorithm on EOG-related ICs, the intrinsic mode functions (IMFs) linked to EOG were discriminated and eliminated. Finally, artifact-free IMFs were projected to obtain the ICs without EOG artifacts, and the clean EEG signals were ultimately reconstructed by the inversion of ICA. Both EOGs correction from simulated EEG signals and real EEG data were studied, which verified that the proposed method could achieve an improved performance in EOG artifacts rejection. By comparing with other existing approaches, the EICA obtained the optimal performance with the highest increase in signal-to-noise ratio and decrease in root mean square error and correlation coefficient after EOG artifacts removal, which demonstrated that the proposed method could more effectively eliminate blink artifacts from multichannel EEG signals with less error influence. This study provided a novel promising method to eliminate EOG artifacts with high performance, which is of great importance for EEG signals processing and analysis.
Collapse
Affiliation(s)
- Chao-Lin Teng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,The Key Laboratory of Neuro-informatics and Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China.,National Engineering Research Center for Healthcare Devices, Guangzhou, China
| | - Yi-Yang Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,The Key Laboratory of Neuro-informatics and Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China.,National Engineering Research Center for Healthcare Devices, Guangzhou, China
| | - Wei Wang
- Department of Psychiatry, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Yuan-Yuan Luo
- Department of Psychology, Xi'an Mental Health Center, Xi'an, China
| | - Gang Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,The Key Laboratory of Neuro-informatics and Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China.,National Engineering Research Center for Healthcare Devices, Guangzhou, China
| | - Jin Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,The Key Laboratory of Neuro-informatics and Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China.,National Engineering Research Center for Healthcare Devices, Guangzhou, China
| |
Collapse
|
10
|
Zhang J, Siegle GJ, Sun T, D'andrea W, Krafty RT. Interpretable principal component analysis for multilevel multivariate functional data. Biostatistics 2021; 24:227-243. [PMID: 34545394 PMCID: PMC10102903 DOI: 10.1093/biostatistics/kxab018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 03/27/2021] [Accepted: 04/12/2021] [Indexed: 11/14/2022] Open
Abstract
Many studies collect functional data from multiple subjects that have both multilevel and multivariate structures. An example of such data comes from popular neuroscience experiments where participants' brain activity is recorded using modalities such as electroencephalography and summarized as power within multiple time-varying frequency bands within multiple electrodes, or brain regions. Summarizing the joint variation across multiple frequency bands for both whole-brain variability between subjects, as well as location-variation within subjects, can help to explain neural reactions to stimuli. This article introduces a novel approach to conducting interpretable principal components analysis on multilevel multivariate functional data that decomposes total variation into subject-level and replicate-within-subject-level (i.e., electrode-level) variation and provides interpretable components that can be both sparse among variates (e.g., frequency bands) and have localized support over time within each frequency band. Smoothness is achieved through a roughness penalty, while sparsity and localization of components are achieved by solving an innovative rank-one based convex optimization problem with block Frobenius and matrix $L_1$-norm-based penalties. The method is used to analyze data from a study to better understand reactions to emotional information in individuals with histories of trauma and the symptom of dissociation, revealing new neurophysiological insights into how subject- and electrode-level brain activity are associated with these phenomena. Supplementary materials for this article are available online.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Biostatistics, University of Pittsburgh, 130 De Soto Street, Pittsburgh, PA, 15261, USA
| | - Greg J Siegle
- Department of Psychiatry, University of Pittsburgh, 3811 O'Hara Street, Pittsburgh, PA, 15213, USA
| | - Tao Sun
- Center for Applied Statistics, School of Statistics, Renmin University of China, 59 Zhongguancun Street, Beijing, 100872, China
| | - Wendy D'andrea
- Department of Psychology, New School for Social Research, 80 Fifth Avenue, New York, NY, 10011, USA
| | - Robert T Krafty
- Department of Biostatistics and Bioinformatics, Emory University, 1518 Clifton Road NE, Atlanta, GA, 30322, USA
| |
Collapse
|
11
|
ElSayed NE, Tolba AS, Rashad MZ, Belal T, Sarhan S. Multimodal analysis of electroencephalographic and electrooculographic signals. Comput Biol Med 2021; 137:104809. [PMID: 34517160 DOI: 10.1016/j.compbiomed.2021.104809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 08/24/2021] [Accepted: 08/24/2021] [Indexed: 11/18/2022]
Abstract
Electrooculography (EOG) is a method to concurrently obtain electrophysiological signals accompanying an Electroencephalography (EEG), where both methods have a common cerebral pattern and imply a similar medical significance. The most common electrophysiological signal source is EOG that contaminated the EEG signal and thereby decreases the accuracy of measurement and the predicated signal strength. In this study, we introduce a method to improve the correction efficiency for EOG artifacts (EOAs) on raw EEG recordings: We retrieve cerebral information from three EEG signals with high system performance and accuracy by applying feature engineering and a novel machine-learning (ML) procedure. To this end, we use two adaptive algorithms for signal decomposition to remove EOAs from multichannel EEG signals: empirical mode decomposition (EMD) and complete ensemble empirical mode decomposition (CEEMD), both using the Hilbert-Huang transform. First, the signal components are decomposed into multiple intrinsic mode functions. Next, statistical feature extraction and dimension reduction using principal component analysis are employed to select optimal feature sets for the ML procedure that is based on classification and regression models. The proposed CEEMD algorithm enhances the accuracy compared to the EMD algorithm and considerably improves the multi-sensory classification of EEG signals. Models of three different categories are applied, and the classification is based on a K-nearest neighbor (k-NN) algorithm, a decision tree (DT) algorithm, and a support vector machine (SVM) algorithm with accuracies of 94% for K-NN, 75% for DT, and 69% for SVM. For each classification model, a regression learner is used to assist as an evidence rule for the proposed artificial system and to influence the learning process from classification and regression models. The regression learning algorithms applied include algorithms based on an ensemble of trees (ET), a DT, and a SVM. We find that the ET-based regression model exhibits a determination coefficient R2 = 1.00 outperforming the other two approaches with R2 = 0.80 for DT and R2 = 0.76 for SVM.
Collapse
Affiliation(s)
- Nesma E ElSayed
- Department of Computer Science, Faculty of Computers and Information, Mansoura University, 35511, Egypt; Delta Higher Institute for Computers, 35511, Egypt
| | - A S Tolba
- Department of Computer Science, Faculty of Computers and Information, Mansoura University, 35511, Egypt
| | - M Z Rashad
- Department of Computer Science, Faculty of Computers and Information, Mansoura University, 35511, Egypt
| | - Tamer Belal
- Department of Neurology, Faculty of Medicine, Mansoura University, 35511, Egypt
| | - Shahenda Sarhan
- Department of Computer Science, Faculty of Computers and Information, Mansoura University, 35511, Egypt.
| |
Collapse
|
12
|
Bisht A, Singh P, Kaur C, Agarwal S, Ajmani M. Progress and Challenges in Physiological Artifacts' Detection in Electroencephalographic Readings. Curr Med Imaging 2021; 18:509-531. [PMID: 34503420 DOI: 10.2174/1573405617666210908124704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 05/04/2021] [Accepted: 06/08/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND Electroencephalographic (EEG) recordings are used to trace neural activity within the cortex to study brain functioning over time. INTRODUCTION During data acquisition, the unequivocal way to reduce artifact is to avoid artifact stimulating events. Though there are certain artifacts that make this task challenging due to their association with the internal human mechanism, in the human-computer interface, these physiological artifacts are of great assistance and act as a command signal for controlling a device or an application (communication). That is why pre-processing of electroencephalographic readings has been a progressive area of exploration, as none of the published work can be viewed as a benchmark for constructive artifact handling. METHOD This review offers a comprehensive insight into state of the art physiological artifact removal techniques listed so far. The study commences from the single-stage traditional techniques to the multistage techniques, examining the pros and cons of each discussed technique. Also, this review paper gives a general idea of various datasets available and briefs the topical trend in EEG signal processing. RESULT Comparing the state of the art techniques with hybrid ones on the basis of performance and computational complexity, it has been observed that the single-channel techniques save computational time but lack in effective artifact removal especially physiological artifacts. On the other hand, hybrid techniques merge the essential characteristics resulting in increased performance, but time consumption and complexity remain an issue. CONCLUSION Considering the high probability of the presence of multiple artifacts in EEG channels, a trade-off between performance, time and computational complexity is the only key for effective processing of artifacts in the time ahead. This paper is anticipated to facilitate upcoming researchers in enriching the contemporary artifact handling techniques to mitigate the expert's burden.
Collapse
Affiliation(s)
- Amandeep Bisht
- Department of Electronics and Communications, UIET, Sector 25, Panjab University, Chandigarh-160014. India
| | - Preeti Singh
- Department of Electronics and Communications, UIET, Sector 25, Panjab University, Chandigarh-160014. India
| | - Chamandeep Kaur
- Department of Electronics and Communications, UIET, Sector 25, Panjab University, Chandigarh-160014. India
| | - Sunil Agarwal
- Department of Electronics and Communications, UIET, Sector 25, Panjab University, Chandigarh-160014. India
| | | |
Collapse
|
13
|
Ranjan R, Chandra Sahana B, Kumar Bhandari A. Ocular artifact elimination from electroencephalography signals: A systematic review. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
14
|
Li M, Zhang Y. An improved MAMA-EMD for the automatic removal of EOG artifacts. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
15
|
Wang X, Xiao Y, Deng F, Chen Y, Zhang H. Eye-Movement-Controlled Wheelchair Based on Flexible Hydrogel Biosensor and WT-SVM. BIOSENSORS 2021; 11:198. [PMID: 34208524 PMCID: PMC8234407 DOI: 10.3390/bios11060198] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/31/2021] [Accepted: 06/07/2021] [Indexed: 11/17/2022]
Abstract
To assist patients with restricted mobility to control wheelchair freely, this paper presents an eye-movement-controlled wheelchair prototype based on a flexible hydrogel biosensor and Wavelet Transform-Support Vector Machine (WT-SVM) algorithm. Considering the poor deformability and biocompatibility of rigid metal electrodes, we propose a flexible hydrogel biosensor made of conductive HPC/PVA (Hydroxypropyl cellulose/Polyvinyl alcohol) hydrogel and flexible PDMS (Polydimethylsiloxane) substrate. The proposed biosensor is affixed to the wheelchair user's forehead to collect electrooculogram (EOG) and strain signals, which are the basis to recognize eye movements. The low Young's modulus (286 KPa) and exceptional breathability (18 g m-2 h-1 of water vapor transmission rate) of the biosensor ensures a conformal and unobtrusive adhesion between it and the epidermis. To improve the recognition accuracy of eye movements (straight, upward, downward, left, and right), the WT-SVM algorithm is introduced to classify EOG and strain signals according to different features (amplitude, duration, interval). The average recognition accuracy reaches 96.3%, thus the wheelchair can be manipulated precisely.
Collapse
Affiliation(s)
| | | | - Fangming Deng
- School of Electrical and Automation Engineering, East China Jiaotong University, Nanchang 330013, China; (X.W.); (Y.X.); (Y.C.); (H.Z.)
| | | | | |
Collapse
|
16
|
EEG Signal denoising using hybrid approach of Variational Mode Decomposition and wavelets for depression. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2020.102337] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
17
|
Li Y, Wang PT, Vaidya MP, Flint RD, Liu CY, Slutzky MW, Do AH. Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)-A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG. Front Neurosci 2021; 14:597941. [PMID: 33584176 PMCID: PMC7873899 DOI: 10.3389/fnins.2020.597941] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 12/11/2020] [Indexed: 12/01/2022] Open
Abstract
Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can not effectively remove most of EMG artifacts. Here, we proposed a modified ICA model for EMG artifacts removal in the EEG, which is called EMG Removal by Adding Sources of EMG (ERASE). In this new approach, additional channels of real EMG from neck and head muscles (reference artifacts) were added as inputs to ICA in order to “force” the most power from EMG artifacts into a few independent components (ICs). The ICs containing EMG artifacts (the “artifact ICs”) were identified and rejected using an automated procedure. ERASE was validated first using both simulated and experimentally-recorded EEG and EMG. Simulation results showed ERASE removed EMG artifacts from EEG significantly more effectively than conventional ICA. Also, it had a low false positive rate and high sensitivity. Subsequently, EEG was collected from 8 healthy participants while they moved their hands to test the realistic efficacy of this approach. Results showed that ERASE successfully removed EMG artifacts (on average, about 75% of EMG artifacts were removed when using real EMGs as reference artifacts) while preserving the expected EEG features related to movement. We also tested the ERASE procedure using simulated EMGs as reference artifacts (about 63% of EMG artifacts removed). Compared to conventional ICA, ERASE removed on average 26% more EMG artifacts from EEG. These findings suggest that ERASE can achieve significant separation of EEG signal and EMG artifacts without a loss of the underlying EEG features. These results indicate that using additional real or simulated EMG sources can increase the effectiveness of ICA in removing EMG artifacts from EEG. Combined with automated artifact IC rejection, ERASE also minimizes potential user bias. Future work will focus on improving ERASE so that it can also be used in real-time applications.
Collapse
Affiliation(s)
- Yongcheng Li
- Department of Neurology, University of California, Irvine, Irvine, CA, United States
| | - Po T Wang
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, United States
| | - Mukta P Vaidya
- Department of Neurology, Northwestern University, Chicago, IL, United States.,Department of Physiology, Northwestern University, Chicago, IL, United States.,Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - Robert D Flint
- Department of Neurology, Northwestern University, Chicago, IL, United States.,Department of Physiology, Northwestern University, Chicago, IL, United States.,Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - Charles Y Liu
- Department of Neurosurgery, University of Southern California, Los Angeles, CA, United States.,Rancho Los Amigos National Rehabilitation Center, Downey, CA, United States.,Neurorestoration Center, University of Southern California, Los Angeles, CA, United States
| | - Marc W Slutzky
- Department of Neurology, Northwestern University, Chicago, IL, United States.,Department of Physiology, Northwestern University, Chicago, IL, United States.,Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - An H Do
- Department of Neurology, University of California, Irvine, Irvine, CA, United States
| |
Collapse
|
18
|
Kaur C, Singh P, Sahni S. EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach. Basic Clin Neurosci 2021; 12:465-476. [PMID: 35154587 PMCID: PMC8817173 DOI: 10.32598/bcn.2021.1388.2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 03/09/2020] [Accepted: 06/30/2021] [Indexed: 11/20/2022] Open
Abstract
INTRODUCTION Several computer-aided diagnosis systems for depression are suggested for use by clinicians to authorize the diagnosis. EEG may be used as an objective analysis tool for identifying depression in the initial stage to avoid it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. METHODS This work proposes a novel denoising method based on Empirical Mode Decomposition (EMD) (with Detrended Fluctuation Analysis (DFA) and wavelet packet transform. Initially, real EEG recordings corresponding to depression patients are decomposed into various mode functions by applying EMD. Then, DFA is used as the mode selection criteria. Further Wavelet Packets Decomposition (WPD)-based evaluation is applied to extract the cleaner signal. RESULTS Simulations were conducted on real EEG databases for depression to demonstrate the effects of the proposed techniques. To conclude the efficacy of the proposed technique, SNR and MAE were identified. The obtained results indicated improved signal-to-noise ratio and lower values of MAE for the combined EMD-DFA-WPD technique. Additionally, Random Forest and SVM (Support Vector Machine)-based classification revealed the improved accuracy of 98.51% and 98.10% for the proposed denoising technique. Whereas the accuracy of the EMD- DFA is 98.01% and 95.81% and EMD combined with DWT technique equaled98.0% and 97.21% for the EMD- DFA technique for RF and SVM, respectively, compared to the proposed method. Furthermore, the classification performance for both classifiers was compared with and without denoising to highlight the effects of the proposed technique. CONCLUSION Proposed denoising system results in better classification of depressed and healthy individuals resulting in a better diagnosing system. These results can be further analyzed using other approaches as a solution to the mode mixing problem of the EMD approach.
Collapse
Affiliation(s)
- Chamandeep Kaur
- Department of Electronics and Communication Engineering, Panjab University Chandigarh, Chandigarh, India
| | - Preeti Singh
- Department of Electronics and Communication Engineering, Panjab University Chandigarh, Chandigarh, India.,Corresponding Author: Preeti Singh, PhD. Address:Department of Electronics and Communication Engineering, Panjab University Chandigarh, Chandigarh, India.Tel:+91 (998) 8898773E-mail:
| | - Sukhtej Sahni
- Department of Psychiatry, Cheema Medical Complex, Mohali, India
| |
Collapse
|
19
|
Jiang Y, Chen C, Zhang X, Chen C, Zhou Y, Ni G, Muh S, Lemos S. Shoulder muscle activation pattern recognition based on sEMG and machine learning algorithms. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105721. [PMID: 32882593 DOI: 10.1016/j.cmpb.2020.105721] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 08/19/2020] [Indexed: 02/05/2023]
Abstract
BACKGROUND AND OBJECTIVE Surface electromyography (sEMG) has been used for robotic rehabilitation engineering for volitional control of hand prostheses or elbow exoskeleton, however, using sEMG for volitional control of an upper limb exoskeleton has not been perfectly developed. The long-term goal of our study is to process shoulder muscle bio-electrical signals for rehabilitative robotic assistive device motion control. The purposes of this study included: 1) to test the feasibility of machine learning algorithms in shoulder motion pattern recognition using sEMG signals from shoulder and upper limb muscles, 2) to investigate the influence of motion speed, individual variability, EMG recording device, and the amount of EMG datasets on the shoulder motion pattern recognition accuracy. METHODS A novel convolutional neural network (CNN) structure was constructed to process EMG signals from 12 muscles for the pattern recognition of upper arm motions including resting, drinking, backward-forward motion, and abduction motion. The accuracy of the CNN models for pattern recognition under different motion speeds, among individuals, and by EMG recording devices was statistically analyzed using ANOVA, GLM Univariate analysis, and Chi-square tests. The influence of EMG dataset number used for CNN model training on recognition accuracy was studied by gradually increasing dataset number until the highest accuracy was obtained. RESULTS Results showed that the accuracy of the normal speed CNN model in motion pattern recognition was 97.57% for normal speed motions and 97.07% for fast speed motions. The accuracy of the cross-subjects CNN model in motion pattern recognition was 79.64%. The accuracy of the cross-device CNN model in motion pattern recognition was 88.93% for normal speed motion and 80.87% for mixed speed. There was a statistical difference in pattern recognition accuracy between different CNN models. CONCLUSION The EMG signals of shoulder and upper arm muscles from the upper limb motions can be processed using CNN algorithms to recognize the identical motions of the upper limb including drinking, forward/backward, abduction, and resting. A simple CNN model trained by EMG datasets of a designated motion speed accurately detected the motion patterns of the same motion speed, yielding the highest accuracy compared with other mixed CNN models for various speeds of motion pattern recognition. Increase of the number of EMG datasets for CNN model training improved the pattern recognition accuracy.
Collapse
Affiliation(s)
- Yongyu Jiang
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi Province, China
| | - Christine Chen
- Department of Computer Science, College of Engineering, University of Michigan, Ann Arbor, USA
| | - Xiaodong Zhang
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi Province, China.
| | - Chaoyang Chen
- Department of Orthopaedic Surgery and Sports Medicine, Detroit Medical Center, Detroit, MI, USA; Robotic Rehabilitation Lab, Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA; Department of Rehabilitation Medicine, First Affiliated Hospital, Fujian Medical University, Fuzhou, China.
| | - Yang Zhou
- Robotic Rehabilitation Lab, Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Guoxin Ni
- Department of Rehabilitation Medicine, First Affiliated Hospital, Fujian Medical University, Fuzhou, China
| | - Stephanie Muh
- Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, MI, USA
| | - Stephen Lemos
- Department of Orthopaedic Surgery and Sports Medicine, Detroit Medical Center, Detroit, MI, USA
| |
Collapse
|
20
|
Li Y, Wang PT, Vaidya MP, Flint RD, Liu CY, Slutzky MW, Do AH. Refinement of High-Gamma EEG Features From TBI Patients With Hemicraniectomy Using an ICA Informed by Simulated Myoelectric Artifacts. Front Neurosci 2020; 14:599010. [PMID: 33328870 PMCID: PMC7732541 DOI: 10.3389/fnins.2020.599010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 10/30/2020] [Indexed: 11/20/2022] Open
Abstract
Recent studies have shown the ability to record high-γ signals (80-160 Hz) in electroencephalogram (EEG) from traumatic brain injury (TBI) patients who have had hemicraniectomies. However, extraction of the movement-related high-γ remains challenging due to a confounding bandwidth overlap with surface electromyogram (EMG) artifacts related to facial and head movements. In our previous work, we described an augmented independent component analysis (ICA) approach for removal of EMG artifacts from EEG, and referred to as EMG Reduction by Adding Sources of EMG (ERASE). Here, we tested this algorithm on EEG recorded from six TBI patients with hemicraniectomies while they performed a thumb flexion task. ERASE removed a mean of 52 ± 12% (mean ± S.E.M) (maximum 73%) of EMG artifacts. In contrast, conventional ICA removed a mean of 27 ± 19% (mean ± S.E.M) of EMG artifacts from EEG. In particular, high-γ synchronization was significantly improved in the contralateral hand motor cortex area within the hemicraniectomy site after ERASE was applied. A more sophisticated measure of high-γ complexity is the fractal dimension (FD). Here, we computed the FD of EEG high-γ on each channel. Relative FD of high-γ was defined as that the FD in move state was subtracted by FD in idle state. We found relative FD of high-γ over hemicraniectomy after applying ERASE were strongly correlated to the amplitude of finger flexion force. Results showed that significant correlation coefficients across the electrodes related to thumb flexion averaged ~0.76, while the coefficients across the homologous electrodes in non-hemicraniectomy areas were nearly 0. After conventional ICA, a correlation between relative FD of high-γ and force remained high in both hemicraniectomy areas (up to 0.86) and non-hemicraniectomy areas (up to 0.81). Across all subjects, an average of 83% of electrodes significantly correlated with force was located in the hemicraniectomy areas after applying ERASE. After conventional ICA, only 19% of electrodes with significant correlations were located in the hemicraniectomy. These results indicated that the new approach isolated electrophysiological features during finger motor activation while selectively removing confounding EMG artifacts. This approach removed EMG artifacts that can contaminate high-gamma activity recorded over the hemicraniectomy.
Collapse
Affiliation(s)
- Yongcheng Li
- Department of Neurology, University of California, Irvine, Irvine, CA, United States
| | - Po T. Wang
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, United States
| | - Mukta P. Vaidya
- Department of Neurology, Northwestern University, Chicago, IL, United States
- Department of Physiology, Northwestern University, Chicago, IL, United States
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - Robert D. Flint
- Department of Neurology, Northwestern University, Chicago, IL, United States
- Department of Physiology, Northwestern University, Chicago, IL, United States
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - Charles Y. Liu
- Department of Neurosurgery, University of Southern California, Los Angeles, CA, United States
- Rancho Los Amigos National Rehabilitation Center, Downey, CA, United States
- Neurorestoration Center, University of Southern California, Los Angeles, CA, United States
| | - Marc W. Slutzky
- Department of Neurology, Northwestern University, Chicago, IL, United States
- Department of Physiology, Northwestern University, Chicago, IL, United States
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, United States
| | - An H. Do
- Department of Neurology, University of California, Irvine, Irvine, CA, United States
| |
Collapse
|
21
|
Patel R, Gireesan K, Sengottuvel S. Decoding non-linearity for effective extraction of the eye-blink artifact pattern from EEG recordings. Pattern Recognit Lett 2020. [DOI: 10.1016/j.patrec.2018.01.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
22
|
|
23
|
Dora C, Biswal PK. An improved algorithm for efficient ocular artifact suppression from frontal EEG electrodes using VMD. Biocybern Biomed Eng 2020. [DOI: 10.1016/j.bbe.2019.03.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
24
|
Benda M, Volosyak I. Peak Detection with Online Electroencephalography (EEG) Artifact Removal for Brain-Computer Interface (BCI) Purposes. Brain Sci 2019; 9:E347. [PMID: 31795398 PMCID: PMC6955994 DOI: 10.3390/brainsci9120347] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 11/19/2019] [Accepted: 11/25/2019] [Indexed: 11/16/2022] Open
Abstract
Brain-computer interfaces (BCIs) measure brain activity and translate it to control computer programs or external devices. However, the activity generated by the BCI makes measurements for objective fatigue evaluation very difficult, and the situation is further complicated due to different movement artefacts. The BCI performance could be increased if an online method existed to measure the fatigue objectively and accurately. While BCI-users are moving, a novel automatic online artefact removal technique is used to filter out these movement artefacts. The effects of this filter on BCI performance and mainly on peak frequency detection during BCI use were investigated in this paper. A successful peak alpha frequency measurement can lead to more accurately determining objective user fatigue. Fifteen subjects performed various imaginary and actual movements in separate tasks, while fourteen electroencephalography (EEG) electrodes were used. Afterwards, a steady-state visual evoked potential (SSVEP)-based BCI speller was used, and the users were instructed to perform various movements. An offline curve fitting method was used for alpha peak detection to assess the effect of the artefact filtering. Peak detection was improved by the filter, by finding 10.91% and 9.68% more alpha peaks during simple EEG recordings and BCI use, respectively. As expected, BCI performance deteriorated from movements, and also from artefact removal. Average information transfer rates (ITRs) were 20.27 bit/min, 16.96 bit/min, and 14.14 bit/min for the (1) movement-free, (2) the moving and unfiltered, and (3) the moving and filtered scenarios, respectively.
Collapse
Affiliation(s)
| | - Ivan Volosyak
- Faculty of Technology and Bionics, Rhine-Waal University of Applied Sciences, 47533 Kleve, Germany
| |
Collapse
|
25
|
Zheng Y, Xu G. Quantifying mode mixing and leakage in multivariate empirical mode decomposition and application in motor imagery-based brain-computer interface system. Med Biol Eng Comput 2019; 57:1297-1311. [PMID: 30737625 DOI: 10.1007/s11517-019-01960-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 01/28/2019] [Indexed: 10/27/2022]
Abstract
Improper selection of the number and the amplitude of noise channels in noise-assisted multivariate empirical mode decomposition (NA-MEMD) would induce mode mixing and leakage in the obtained intrinsic mode functions (IMF), which would degrade the performance in applications like brain-computer interface (BCI) systems based on motor imagery. A measurement (ML-index) using no prior knowledge of the underlying components of the original signals was proposed to quantify the amount of mode mixing and leakage of IMFs. Both synthetic signals and electroencephalography (EEG) recordings from motor imagery experiments were used to test the validity. The BCI classification performance using NA-MEMD with the optimal parameters selected based on the ML-index was compared with the performance under the non-optimal parameter condition and the performance using the conventional filtering method. Test on synthetic signals demonstrated the ML-index can effectively quantify the amount of mode mixing and leakage, and help to improve the accuracy of extracting the underlying components. Test on EEG recordings showed the BCI classification performance can be significantly improved under the optimal parameter condition. This study provided a method to quantify the amount of mode mixing and leakage in IMFs and realized the optimization of the parameters associated with noise channels in NA-MEMD. Graphical abstract One of the synthetic multivariate signals comprised four components oscillating at different rates (middle column). Noise-assisted multivariate empirical mode decomposition (noise-assisted MEMD) was used to extract different components. Mode mixing issue occurred under the non-optimal parameter condition (left column). The issue was alleviated under the optimal parameter condition (right column) which can be obtained with the proposed method in this study.
Collapse
Affiliation(s)
- Yang Zheng
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
| | - Guanghua Xu
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| |
Collapse
|
26
|
Guarnieri R, Marino M, Barban F, Ganzetti M, Mantini D. Online EEG artifact removal for BCI applications by adaptive spatial filtering. J Neural Eng 2018; 15:056009. [DOI: 10.1088/1741-2552/aacfdf] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
27
|
Gaussian Elimination-Based Novel Canonical Correlation Analysis Method for EEG Motion Artifact Removal. JOURNAL OF HEALTHCARE ENGINEERING 2017; 2017:9674712. [PMID: 29118966 PMCID: PMC5651166 DOI: 10.1155/2017/9674712] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 06/07/2017] [Indexed: 11/17/2022]
Abstract
The motion generated at the capturing time of electro-encephalography (EEG) signal leads to the artifacts, which may reduce the quality of obtained information. Existing artifact removal methods use canonical correlation analysis (CCA) for removing artifacts along with ensemble empirical mode decomposition (EEMD) and wavelet transform (WT). A new approach is proposed to further analyse and improve the filtering performance and reduce the filter computation time under highly noisy environment. This new approach of CCA is based on Gaussian elimination method which is used for calculating the correlation coefficients using backslash operation and is designed for EEG signal motion artifact removal. Gaussian elimination is used for solving linear equation to calculate Eigen values which reduces the computation cost of the CCA method. This novel proposed method is tested against currently available artifact removal techniques using EEMD-CCA and wavelet transform. The performance is tested on synthetic and real EEG signal data. The proposed artifact removal technique is evaluated using efficiency matrices such as del signal to noise ratio (DSNR), lambda (λ), root mean square error (RMSE), elapsed time, and ROC parameters. The results indicate suitablity of the proposed algorithm for use as a supplement to algorithms currently in use.
Collapse
|
28
|
Automatic Artifact Removal in EEG of Normal and Demented Individuals Using ICA-WT during Working Memory Tasks. SENSORS 2017; 17:s17061326. [PMID: 28594352 PMCID: PMC5492863 DOI: 10.3390/s17061326] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 04/25/2017] [Accepted: 05/04/2017] [Indexed: 01/31/2023]
Abstract
Characterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wavelet transform (WT), that is, the AICA–WT technique; second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. The proposed AICA–WT technique is a four-stage approach. In the first stage, the independent components (ICs) were estimated. In the second stage, three-step artifact identification metrics were applied to detect the artifactual components. The components identified as artifacts were marked as critical and denoised through DWT in the third stage. In the fourth stage, the corrected ICs were reconstructed to obtain artifact-free EEG signals. The performance of the proposed AICA–WT technique was compared with those of two other techniques based on AICA and WT denoising methods using cross-correlation XCorr and peak signal to noise ratio (PSNR) (ANOVA, p ˂ 0.05). The AICA–WT technique exhibited the best artifact removal performance. The assumption that there would be a deceleration of EEG dominant frequencies in VaD and MCI patients compared with control subjects was assessed with AICA–WT (ANOVA, p ˂ 0.05). Therefore, this study may provide information on post-stroke dementia particularly VaD and stroke-related MCI patients through spectral analysis of EEG background activities that can help to provide useful diagnostic indexes by using EEG signal processing.
Collapse
|
29
|
Wind Turbine Diagnosis under Variable Speed Conditions Using a Single Sensor Based on the Synchrosqueezing Transform Method. SENSORS 2017; 17:s17051149. [PMID: 28524090 PMCID: PMC5470895 DOI: 10.3390/s17051149] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 04/28/2017] [Accepted: 04/28/2017] [Indexed: 11/17/2022]
Abstract
The gearbox is one of the key components in wind turbines. Gearbox fault signals are usually nonstationary and highly contaminated with noise. The presence of amplitude-modulated and frequency-modulated (AM-FM) characteristics compound the difficulty of precise fault diagnosis of wind turbines, therefore, it is crucial to develop an effective fault diagnosis method for such equipment. This paper presents an improved diagnosis method for wind turbines via the combination of synchrosqueezing transform and local mean decomposition. Compared to the conventional time-frequency analysis techniques, the improved method which is performed in non-real-time can effectively reduce the noise pollution of the signals and preserve the signal characteristics, and hence is suitable for the analysis of nonstationary signals with high noise. This method is further validated by simulated signals and practical vibration data measured from a 1.5 MW wind turbine. The results confirm that the proposed method can simultaneously control the noise and increase the accuracy of time-frequency representation.
Collapse
|
30
|
Numerical Control Machine Tool Fault Diagnosis Using Hybrid Stationary Subspace Analysis and Least Squares Support Vector Machine with a Single Sensor. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7040346] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
31
|
Patel R, Gireesan K, Sengottuvel S, Janawadkar MP, Radhakrishnan TS. Common Methodology for Cardiac and Ocular Artifact Suppression from EEG Recordings by Combining Ensemble Empirical Mode Decomposition with Regression Approach. J Med Biol Eng 2017. [PMID: 29541010 PMCID: PMC5840220 DOI: 10.1007/s40846-016-0208-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Electroencephalography (EEG) is a non-invasive way of recording brain activities, making it useful for diagnosing various neurological disorders. However, artifact signals associated with eye blinks or the heart spread across the scalp, contaminating EEG recordings and making EEG data analysis difficult. To solve this problem, we implement a common methodology to suppress both cardiac and ocular artifact signal, by correlating the measured contaminated EEG signals with the clean reference electro-oculography (EOG) and electrocardiography (EKG) data and subtracting the scaled EOG and EKG from the contaminated EEG recording. In the proposed methodology, the clean EOG and EKG signals are extracted by subjecting the raw reference time-series data to ensemble empirical mode decomposition to obtain the intrinsic mode functions. Then, an unsupervised technique is used to capture the artifact components. We compare the distortion introduced into the brain signal after artifact suppression using the proposed method with those obtained using conventional regression alone and with a wavelet-based approach. The results show that the proposed method outperforms the other techniques, with an additional advantage of being a common methodology for the suppression of two types of artifact.
Collapse
Affiliation(s)
- Rajesh Patel
- MEG Laboratory, SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 India
| | - K Gireesan
- MEG Laboratory, SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 India
| | - S Sengottuvel
- MEG Laboratory, SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 India
| | - M P Janawadkar
- MEG Laboratory, SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 India
| | - T S Radhakrishnan
- MEG Laboratory, SQUIDs and Applications Section, Condensed Matter Physics Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102 India
| |
Collapse
|
32
|
Minguillon J, Lopez-Gordo MA, Pelayo F. Trends in EEG-BCI for daily-life: Requirements for artifact removal. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.09.005] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
33
|
Abstract
Electrooculogram (EOG) artifact contamination is a common critical issue in general electroencephalogram (EEG) studies as well as in brain-computer interface (BCI) research. It is especially challenging when dedicated EOG channels are unavailable or when there are very few EEG channels available for independent component analysis based ocular artifact removal. It is even more challenging to avoid loss of the signal of interest during the artifact correction process, where the signal of interest can be multiple magnitudes weaker than the artifact. To address these issues, we propose a novel discriminative ocular artifact correction approach for feature learning in EEG analysis. Without extra ocular movement measurements, the artifact is extracted from raw EEG data, which is totally automatic and requires no visual inspection of artifacts. Then, artifact correction is optimized jointly with feature extraction by maximizing oscillatory correlations between trials from the same class and minimizing them between trials from different classes. We evaluate this approach on a real-world EEG dataset comprising 68 subjects performing cognitive tasks. The results showed that the approach is capable of not only suppressing the artifact components but also improving the discriminative power of a classifier with statistical significance. We also demonstrate that the proposed method addresses the confounding issues induced by ocular movements in cognitive EEG study.
Collapse
|
34
|
Zeng H, Song A. Optimizing Single-Trial EEG Classification by Stationary Matrix Logistic Regression in Brain-Computer Interface. IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS 2016; 27:2301-2313. [PMID: 26513804 DOI: 10.1109/tnnls.2015.2475618] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In addition to the noisy and limited spatial resolution characteristics of the electroencephalography (EEG) signal, the intrinsic nonstationarity in the EEG data makes the single-trial EEG classification an even more challenging problem in brain-computer interface (BCI). Variations of the signal properties within a session often result in deteriorated classification performance. This is mainly attributed to the reason that the routine feature extraction or classification method does not take the changes in the signal into account. Although several extensions to the standard feature extraction method have been proposed to reduce the sensitivity to nonstationarity in data, they optimize different objective functions from that of the subsequent classification model, and thereby, the extracted features may not be optimized for the classification. In this paper, we propose an approach that directly optimizes the classifier's discriminativity and robustness against the within-session nonstationarity of the EEG data through a single optimization paradigm, and show that it can greatly improve the performance, in particular for the subjects who have difficulty in controlling a BCI. Moreover, the experimental results on two benchmark data sets demonstrate that our approach significantly outperforms the compared approaches in reducing classification error rates.
Collapse
|
35
|
Islam MK, Rastegarnia A, Yang Z. Methods for artifact detection and removal from scalp EEG: A review. Neurophysiol Clin 2016; 46:287-305. [PMID: 27751622 DOI: 10.1016/j.neucli.2016.07.002] [Citation(s) in RCA: 156] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 05/29/2016] [Accepted: 07/07/2016] [Indexed: 11/29/2022] Open
Abstract
Electroencephalography (EEG) is the most popular brain activity recording technique used in wide range of applications. One of the commonly faced problems in EEG recordings is the presence of artifacts that come from sources other than brain and contaminate the acquired signals significantly. Therefore, much research over the past 15 years has focused on identifying ways for handling such artifacts in the preprocessing stage. However, this is still an active area of research as no single existing artifact detection/removal method is complete or universal. This article presents an extensive review of the existing state-of-the-art artifact detection and removal methods from scalp EEG for all potential EEG-based applications and analyses the pros and cons of each method. First, a general overview of the different artifact types that are found in scalp EEG and their effect on particular applications are presented. In addition, the methods are compared based on their ability to remove certain types of artifacts and their suitability in relevant applications (only functional comparison is provided not performance evaluation of methods). Finally, the future direction and expected challenges of current research is discussed. Therefore, this review is expected to be helpful for interested researchers who will develop and/or apply artifact handling algorithm/technique in future for their applications as well as for those willing to improve the existing algorithms or propose a new solution in this particular area of research.
Collapse
Affiliation(s)
- Md Kafiul Islam
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore
| | - Amir Rastegarnia
- Department of Electrical Engineering, University of Malayer, Malayer, Iran.
| | - Zhi Yang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore
| |
Collapse
|
36
|
Mannan MMN, Jeong MY, Kamran MA. Hybrid ICA-Regression: Automatic Identification and Removal of Ocular Artifacts from Electroencephalographic Signals. Front Hum Neurosci 2016; 10:193. [PMID: 27199714 PMCID: PMC4853904 DOI: 10.3389/fnhum.2016.00193] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 04/18/2016] [Indexed: 11/13/2022] Open
Abstract
Electroencephalography (EEG) is a portable brain-imaging technique with the advantage of high-temporal resolution that can be used to record electrical activity of the brain. However, it is difficult to analyze EEG signals due to the contamination of ocular artifacts, and which potentially results in misleading conclusions. Also, it is a proven fact that the contamination of ocular artifacts cause to reduce the classification accuracy of a brain-computer interface (BCI). It is therefore very important to remove/reduce these artifacts before the analysis of EEG signals for applications like BCI. In this paper, a hybrid framework that combines independent component analysis (ICA), regression and high-order statistics has been proposed to identify and eliminate artifactual activities from EEG data. We used simulated, experimental and standard EEG signals to evaluate and analyze the effectiveness of the proposed method. Results demonstrate that the proposed method can effectively remove ocular artifacts as well as it can preserve the neuronal signals present in EEG data. A comparison with four methods from literature namely ICA, regression analysis, wavelet-ICA (wICA), and regression-ICA (REGICA) confirms the significantly enhanced performance and effectiveness of the proposed method for removal of ocular activities from EEG, in terms of lower mean square error and mean absolute error values and higher mutual information between reconstructed and original EEG.
Collapse
Affiliation(s)
- Malik M Naeem Mannan
- Department of Cogno-Mechatronics Engineering, Pusan National University Busan, South Korea
| | - Myung Y Jeong
- Department of Cogno-Mechatronics Engineering, Pusan National University Busan, South Korea
| | - Muhammad A Kamran
- Department of Cogno-Mechatronics Engineering, Pusan National University Busan, South Korea
| |
Collapse
|
37
|
Mannan MMN, Kim S, Jeong MY, Kamran MA. Hybrid EEG--Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal. SENSORS 2016; 16:241. [PMID: 26907276 PMCID: PMC4801617 DOI: 10.3390/s16020241] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2015] [Revised: 02/05/2016] [Accepted: 02/14/2016] [Indexed: 11/22/2022]
Abstract
Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data.
Collapse
Affiliation(s)
- Malik M Naeem Mannan
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Korea.
| | - Shinjung Kim
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Korea.
| | - Myung Yung Jeong
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Korea.
| | - M Ahmad Kamran
- Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Korea.
| |
Collapse
|
38
|
Gu Y, Han J, Liang Z, Yan J, Li Z, Li X. Empirical mode decomposition-based motion artifact correction method for functional near-infrared spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:15002. [PMID: 26747474 DOI: 10.1117/1.jbo.21.1.015002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2015] [Accepted: 11/30/2015] [Indexed: 06/05/2023]
Affiliation(s)
- Yue Gu
- Yanshan University, Institute of Electrical Engineering, No. 438, Hebei Street, Haigang District, Qinhuangdao 066004, China
| | - Junxia Han
- Beijing Normal University, State Key Laboratory of Cognitive Neuroscience and Learning & IDG/McGovern Institute for Brain Research, No. 19, Xinjiekou Wai Street, Haidian District, Beijing 100875, ChinacBeijing Normal University, Center for Collaboration a
| | - Zhenhu Liang
- Yanshan University, Institute of Electrical Engineering, No. 438, Hebei Street, Haigang District, Qinhuangdao 066004, China
| | - Jiaqing Yan
- Yanshan University, Institute of Electrical Engineering, No. 438, Hebei Street, Haigang District, Qinhuangdao 066004, China
| | - Zheng Li
- Beijing Normal University, State Key Laboratory of Cognitive Neuroscience and Learning & IDG/McGovern Institute for Brain Research, No. 19, Xinjiekou Wai Street, Haidian District, Beijing 100875, ChinacBeijing Normal University, Center for Collaboration a
| | - Xiaoli Li
- Beijing Normal University, State Key Laboratory of Cognitive Neuroscience and Learning & IDG/McGovern Institute for Brain Research, No. 19, Xinjiekou Wai Street, Haidian District, Beijing 100875, ChinacBeijing Normal University, Center for Collaboration a
| |
Collapse
|
39
|
Selection of Mother Wavelet Functions for Multi-Channel EEG Signal Analysis during a Working Memory Task. SENSORS 2015; 15:29015-35. [PMID: 26593918 PMCID: PMC4701319 DOI: 10.3390/s151129015] [Citation(s) in RCA: 95] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Accepted: 10/04/2015] [Indexed: 12/03/2022]
Abstract
We performed a comparative study to select the efficient mother wavelet (MWT) basis functions that optimally represent the signal characteristics of the electrical activity of the human brain during a working memory (WM) task recorded through electro-encephalography (EEG). Nineteen EEG electrodes were placed on the scalp following the 10–20 system. These electrodes were then grouped into five recording regions corresponding to the scalp area of the cerebral cortex. Sixty-second WM task data were recorded from ten control subjects. Forty-five MWT basis functions from orthogonal families were investigated. These functions included Daubechies (db1–db20), Symlets (sym1–sym20), and Coiflets (coif1–coif5). Using ANOVA, we determined the MWT basis functions with the most significant differences in the ability of the five scalp regions to maximize their cross-correlation with the EEG signals. The best results were obtained using “sym9” across the five scalp regions. Therefore, the most compatible MWT with the EEG signals should be selected to achieve wavelet denoising, decomposition, reconstruction, and sub-band feature extraction. This study provides a reference of the selection of efficient MWT basis functions.
Collapse
|
40
|
Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2015; 2015:653639. [PMID: 26690500 PMCID: PMC4672363 DOI: 10.1155/2015/653639] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/09/2015] [Accepted: 07/30/2015] [Indexed: 11/18/2022]
Abstract
EEG-controlled gaming applications range widely from strictly medical to completely nonmedical applications. Games can provide not only entertainment but also strong motivation for practicing, thereby achieving better control with rehabilitation system. In this paper we present real-time control of video game with eye movements for asynchronous and noninvasive communication system using two temporal EEG sensors. We used wavelets to detect the instance of eye movement and time-series characteristics to distinguish between six classes of eye movement. A control interface was developed to test the proposed algorithm in real-time experiments with opened and closed eyes. Using visual feedback, a mean classification accuracy of 77.3% was obtained for control with six commands. And a mean classification accuracy of 80.2% was obtained using auditory feedback for control with five commands. The algorithm was then applied for controlling direction and speed of character movement in two-dimensional video game. Results showed that the proposed algorithm had an efficient response speed and timing with a bit rate of 30 bits/min, demonstrating its efficacy and robustness in real-time control.
Collapse
|
41
|
Wang FT, Chan HL, Wang CL, Jian HM, Lin SH. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition. SENSORS 2015. [PMID: 26198231 PMCID: PMC4541883 DOI: 10.3390/s150716372] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method.
Collapse
Affiliation(s)
- Fu-Tai Wang
- Department of Electrical Engineering, Hwa Hsia University of Technology, 111, Gongzhuan Rd., Zhonghe, New Taipei City 23568, Taiwan.
| | - Hsiao-Lung Chan
- Department of Electrical Engineering, Chang Gung University, 259 Wenhwa 1st Road, Kweishan, Taoyuan 33302, Taiwan.
| | - Chun-Li Wang
- Department of Cardiology, Chang Gung Memorial Hospital, 5 Fu-Hsing Street, Kweishan, Taoyuan 33305, Taiwan.
| | - Hung-Ming Jian
- Department of Electrical Engineering, Chang Gung University, 259 Wenhwa 1st Road, Kweishan, Taoyuan 33302, Taiwan.
| | - Sheng-Hsiung Lin
- Department of Electrical Engineering, Chang Gung University, 259 Wenhwa 1st Road, Kweishan, Taoyuan 33302, Taiwan.
| |
Collapse
|
42
|
Wang G, Teng C, Li K, Zhang Z, Yan X. The Removal of EOG Artifacts From EEG Signals Using Independent Component Analysis and Multivariate Empirical Mode Decomposition. IEEE J Biomed Health Inform 2015; 20:1301-8. [PMID: 26126290 DOI: 10.1109/jbhi.2015.2450196] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The recorded electroencephalography (EEG) signals are usually contaminated by electrooculography (EOG) artifacts. In this paper, by using independent component analysis (ICA) and multivariate empirical mode decomposition (MEMD), the ICA-based MEMD method was proposed to remove EOG artifacts (EOAs) from multichannel EEG signals. First, the EEG signals were decomposed by the MEMD into multiple multivariate intrinsic mode functions (MIMFs). The EOG-related components were then extracted by reconstructing the MIMFs corresponding to EOAs. After performing the ICA of EOG-related signals, the EOG-linked independent components were distinguished and rejected. Finally, the clean EEG signals were reconstructed by implementing the inverse transform of ICA and MEMD. The results of simulated and real data suggested that the proposed method could successfully eliminate EOAs from EEG signals and preserve useful EEG information with little loss. By comparing with other existing techniques, the proposed method achieved much improvement in terms of the increase of signal-to-noise and the decrease of mean square error after removing EOAs.
Collapse
|
43
|
Enhanced Automatic Wavelet Independent Component Analysis for Electroencephalographic Artifact Removal. ENTROPY 2014. [DOI: 10.3390/e16126553] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
44
|
A preliminary study of muscular artifact cancellation in single-channel EEG. SENSORS 2014; 14:18370-89. [PMID: 25275348 PMCID: PMC4239950 DOI: 10.3390/s141018370] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2014] [Revised: 08/19/2014] [Accepted: 09/23/2014] [Indexed: 11/17/2022]
Abstract
Electroencephalogram (EEG) recordings are often contaminated with muscular artifacts that strongly obscure the EEG signals and complicates their analysis. For the conventional case, where the EEG recordings are obtained simultaneously over many EEG channels, there exists a considerable range of methods for removing muscular artifacts. In recent years, there has been an increasing trend to use EEG information in ambulatory healthcare and related physiological signal monitoring systems. For practical reasons, a single EEG channel system must be used in these situations. Unfortunately, there exist few studies for muscular artifact cancellation in single-channel EEG recordings. To address this issue, in this preliminary study, we propose a simple, yet effective, method to achieve the muscular artifact cancellation for the single-channel EEG case. This method is a combination of the ensemble empirical mode decomposition (EEMD) and the joint blind source separation (JBSS) techniques. We also conduct a study that compares and investigates all possible single-channel solutions and demonstrate the performance of these methods using numerical simulations and real-life applications. The proposed method is shown to significantly outperform all other methods. It can successfully remove muscular artifacts without altering the underlying EEG activity. It is thus a promising tool for use in ambulatory healthcare systems.
Collapse
|