1
|
Liu L, Abdulla W. Improving APT Systems' Performance in Air via Impedance Matching and 3D-Printed Clamp. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115347. [PMID: 37300074 DOI: 10.3390/s23115347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 05/31/2023] [Accepted: 06/01/2023] [Indexed: 06/12/2023]
Abstract
This paper presents a study on improving the performance of the acoustic piezoelectric transducer system in air, as the low acoustic impedance of air leads to suboptimal system performance. Impedance matching techniques can enhance the acoustic power transfer (APT) system's performance in air. This study integrates an impedance matching circuit into the Mason circuit and investigates the impact of fixed constraints on the piezoelectric transducer's sound pressure and output voltage. Additionally, this paper proposes a novel equilateral triangular peripheral clamp that is entirely 3D-printable and cost-effective. This study analyses the peripheral clamp's impedance and distance characteristics and confirms its effectiveness through consistent experimental and simulation results. The findings of this study can aid researchers and practitioners in various fields that employ APT systems to improve their performance in air.
Collapse
Affiliation(s)
- Liu Liu
- Department of Electrical, Computer and Software Engineering, The University of Auckland, Auckland 1010, New Zealand
| | - Waleed Abdulla
- Department of Electrical, Computer and Software Engineering, The University of Auckland, Auckland 1010, New Zealand
| |
Collapse
|
2
|
Svilainis L, Chaziachmetovas A, Kaskonas P, Gomez Alvarez-Arenas TE. Ultrasonic needle hydrophone calibration in air by a parabolic off-axis mirror focused beam using three-transducer reciprocity. ULTRASONICS 2023; 133:107025. [PMID: 37159982 DOI: 10.1016/j.ultras.2023.107025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 04/06/2023] [Accepted: 04/24/2023] [Indexed: 05/11/2023]
Abstract
An acoustic field distribution investigation in air requires a small receiving sensor. Needle hydrophones seem to be an attractive solution, and it has previously been demonstrated that needle hydrophones designed for use in water can be used in air. The metrology problem is that an absolute sensitivity calibration is needed, because needle hydrophones are not characterized in air, especially for frequencies below 1 MHz, which is of interest for air-coupled ultrasound. Conventional, three-transducer/microphone reciprocity calibration requires measurements to be done in the far field. However, when transducer diameter is large and the frequency is high, the required measurement distance becomes very large: 3 m for a 20 mm source, transmitting at 1 MHz. Large propagation distance leads to high attenuation and nonlinear effects in air propagation, and distortion and losses accumulate. Small needle hydrophones have low sensitivity, so that high excitation amplitudes would be required, which can lead to transducer heating and increase nonlinearity effects. A derivative of the three-transducer reciprocity calibration method is proposed, where a large aperture transducer is focused onto a hydrophone, using hybrid of plane wave and spherical wave reciprocity. Use of a focused source minimizes the frequency-dependent diffraction effects, and the spherical wave approximation is valid at the focal distance, and low level excitation signals can be used. Focusing is accomplished using a parabolic off-axis mirror. Calibration is in transmission, which reduces the complexity of the electrical measurements. The corresponding equations have been derived for this setup. Calibration of the transducer and needle hydrophone absolute sensitivity is obtained.
Collapse
Affiliation(s)
- Linas Svilainis
- Electronics Engineering Department, Kaunas University of Technology, Kaunas, LT 51368, Lithuania.
| | - Andrius Chaziachmetovas
- Electronics Engineering Department, Kaunas University of Technology, Kaunas, LT 51368, Lithuania
| | - Paulius Kaskonas
- Electronics Engineering Department, Kaunas University of Technology, Kaunas, LT 51368, Lithuania
| | | |
Collapse
|
3
|
Svilainis L, Chaziachmetovas A, Eidukynas V, Alvarez-Arenas TG, Dixon S. Miniature Ferroelectret Microphone Design and Performance Evaluation Using Laser Excitation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:3392-3401. [PMID: 36331636 DOI: 10.1109/tuffc.2022.3220082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.5-mm-diameter sensitive element ultrasonic microphone. FE has an acoustic impedance much closer to that of air compared with other alternatives and is low cost and easy to process. The performance of the microphone was evaluated by measuring the sensitivity area map, directivity, ac response, and calibrating the absolute sensitivity. Another novel contribution here is that the sensitivity map was obtained by scanning the focused beam of a laser diode over the microphone surface, producing thermoelastic ultrasound excitation. The electroacoustic response of the microphone served as a sensitivity indicator at a scan spot. Micrometer scale granularity of the FE sensitivity was revealed in the sensitivity map images. It was also demonstrated that the relative ac response of the microphone can be obtained using pulsed laser beam thermoelastic excitation of the whole microphone surface with a laser diode. The absolute sensitivity calibration was done using the hybrid three-transducer reciprocity technique. A large aperture, air coupled transducer beam was focused onto the microphone surface, using the parabolic off-axis mirror. This measurement validated the laser ac response measurements. The FE microphone performance was compared with biaxially stretched polyvinylidene difluoride (PVDF) microphone of the same construction.
Collapse
|
4
|
Bhattacharya S, Yadav N, Ahmad A, Melandsø F, Habib A. Multiple Damage Detection in PZT Sensor Using Dual Point Contact Method. SENSORS (BASEL, SWITZERLAND) 2022; 22:9161. [PMID: 36501870 PMCID: PMC9738784 DOI: 10.3390/s22239161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 11/18/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Lead Zirconate Titanate (PZT) is used to make ultrasound transducers, sensors, and actuators due to its large piezoelectric coefficient. Several micro-defects develop in the PZT sensor due to delamination, corrosion, huge temperature fluctuation, etc., causing a decline in its performance. It is thus necessary to identify, locate, and quantify the defects. Non-Destructive Structural Health Monitoring (SHM) is the most optimal and economical evaluation method. Traditional ultrasound SHM techniques have a huge impedance mismatch between air and solid material, and most of the popular signal processing methods define time series signals in only one domain, which provides sub-optimal results for non-stationary signals. Thus, to improve the accuracy of detection, the point contact excitation and detection method is implemented to determine the interaction of ultrasonic waves with micro-scale defects in the PZT. The signal generated from this method being non-stationary in nature, it requires signal processing with changeable resolutions at different times and frequencies. The Haar Discrete Wavelet Transformation (DWT) is applied to the time series data obtained from the coulomb coupling setup. Using the above process, defects up to 100 μm in diameter could be successfully distinguished.
Collapse
Affiliation(s)
- Sayantani Bhattacharya
- Department of Mining Machinery Engineering, Indian Institute of Technology Dhanbad, Dhanbad 826004, India
| | - Nitin Yadav
- Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India
| | - Azeem Ahmad
- Department of Physics and Technology, UiT-The Arctic University of Norway, 9019 Tromsø, Norway
| | - Frank Melandsø
- Department of Physics and Technology, UiT-The Arctic University of Norway, 9019 Tromsø, Norway
| | - Anowarul Habib
- Department of Physics and Technology, UiT-The Arctic University of Norway, 9019 Tromsø, Norway
| |
Collapse
|
5
|
Fabrication and Modeling of Matching System for Air-Coupled Transducer. MICROMACHINES 2022; 13:mi13050781. [PMID: 35630248 PMCID: PMC9143448 DOI: 10.3390/mi13050781] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 05/14/2022] [Accepted: 05/14/2022] [Indexed: 11/17/2022]
Abstract
The tremendous acoustic impedance difference between the piezoelectric composite and air prevents the ultrasonic transition, resulting in low amplitude for the received signal for the composite defect detection using an air-coupled transducer. The matching system, which includes the matching layers and bonding layers attached to the piezoelectric composite, can reduce the acoustic impedance difference and benefit the acoustic transition. In this paper, the fabrication method and modeling for the matching layers are proposed to optimize the transducer performance. The effects of bonding layer material on the transducer performance are also discussed. Experiments were conducted for modeling validation. The proposed model can predict the matching layer acoustic properties with an error of less than 11%. The bonding layer using the same material as the first matching layer can help to increase the sensitivity by about 33% compared to the traditional epoxy bonding. The optimized air-coupled ultrasonic transducer, based on the results of this study, has a 1283 mV amplitude in the air, which is 56% higher than commercially available transducers, and can identify the defects in two typical non-metallic composite materials easily.
Collapse
|
6
|
Bühling B, Maack S, Schweitzer T, Strangfeld C. Enhancing the spectral signatures of ultrasonic fluidic transducer pulses for improved time-of-flight measurements. ULTRASONICS 2022; 119:106612. [PMID: 34735931 DOI: 10.1016/j.ultras.2021.106612] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 09/15/2021] [Accepted: 10/08/2021] [Indexed: 06/13/2023]
Abstract
Air-coupled ultrasonic (ACU) testing has proven to be a valuable method for increasing the speed in non-destructive ultrasonic testing and the investigation of sensitive specimens. A major obstacle to implementing ACU methods is the significant signal power loss at the air-specimen and transducer-air interfaces. The loss between transducer and air can be eliminated by using recently developed fluidic transducers. These transducers use pressurized air and a natural flow instability to generate high sound power signals. Due to this self-excited flow instability, the individual pulses are dissimilar in length, amplitude, and phase. These amplitude and angle modulated pulses offer the great opportunity to further increase the signal-to-noise ratio with pulse compression methods. In practice, multi-input multi-output (MIMO) setups reduce the time required to scan the specimen surface, but demand high pulse discriminability. By applying envelope removal techniques to the individual pulses, the pulse discriminability is increased allowing only the remaining phase information to be targeted for analysis. Finally, semi-synthetic experiments are presented to verify the applicability of the envelope removal method and highlight the suitability of the fluidic transducer for MIMO setups.
Collapse
Affiliation(s)
- Benjamin Bühling
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205, Berlin, Germany.
| | - Stefan Maack
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205, Berlin, Germany
| | | | - Christoph Strangfeld
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205, Berlin, Germany
| |
Collapse
|
7
|
Attenuation of a Slow Subsonic A 0 Mode Ultrasonic Guided Wave in Thin Plastic Films. MATERIALS 2019; 12:ma12101648. [PMID: 31117182 PMCID: PMC6566724 DOI: 10.3390/ma12101648] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 05/13/2019] [Accepted: 05/17/2019] [Indexed: 11/16/2022]
Abstract
The ultrasonic testing technique using Lamb waves is widely used for the non-destructive testing and evaluation of various structures. For air-coupled excitation and the reception of A0 mode Lamb waves, leaky guided waves are usually exploited. However, at low frequencies (<100 kHz), the velocity of this mode in plastic and composite materials can become slower than the ultrasound velocity in air, and its propagation in films is accompanied only by an evanescent wave in air. To date, the information about the attenuation of the slow A0 mode is very contradictory. Therefore, the objective of this investigation was the measurement of the attenuation of the slow A0 mode in thin plastic films. The measurement of the attenuation of normal displacements of the film caused by a propagating slow A0 mode is discussed. The normal displacements of the film at different distances from the source were measured by a laser interferometer. In order to reduce diffraction errors, the measurement method based on the excitation of cylindrical but not plane waves was proposed. The slow A0 mode was excited in the polyvinylchloride film by a dry contact type ultrasonic transducer made of high-efficiency PMN-32%PT strip-like piezoelectric crystal. It was found that that the attenuation of the slow A0 mode in PVC film at the frequency of 44 kHz is 2 dB/cm. The obtained results can be useful for the development of quality control methods for plastic films.
Collapse
|
8
|
Kazys RJ, Mazeika L, Sliteris R, Sestoke J. Air-Coupled Excitation of a Slow A₀ Mode Wave in Thin Plastic Films by an Ultrasonic PMN-32%PT Array. SENSORS 2018; 18:s18093156. [PMID: 30235795 PMCID: PMC6164743 DOI: 10.3390/s18093156] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 09/06/2018] [Accepted: 09/18/2018] [Indexed: 11/16/2022]
Abstract
Ultrasonic non-destructive testing techniques (NDT) based on the application of guided waves are already used for inspection of plate-type structures made of various materials, including composite materials. Air-coupled ultrasonic techniques are used to test such structures by means of guided waves. The objective of this research was development and investigation of air-coupled excitation of a slow A0 Lamb wave mode in thin plastic films by a PMN-32%PT ultrasonic array. It is known that when the velocity of the A0 mode in the film is less than the ultrasound velocity in air no leaky wave is observed in a surrounding air. It opens new possibilities for NDT of composite structures. The influence of the airborne wave may be eliminated by 3D filtering in a wavenumbers-frequency domain. A special filter and corresponding signals processing technique were developed in order to obtain directivity patterns and velocity maps of the waves propagating in all directions. The measured ultrasound velocity values prove that, with the proposed method, it is possible to excite a slow A0 Lamb wave mode and to separate it from other parasitic waves propagating in air. Measurements of the parameters of the slow A0 mode, such as the propagation velocity in the plastic film, may be applied for the material characterization.
Collapse
Affiliation(s)
- Rymantas J Kazys
- Ultrasound Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| | - Liudas Mazeika
- Ultrasound Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| | - Reimondas Sliteris
- Ultrasound Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| | - Justina Sestoke
- Ultrasound Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| |
Collapse
|
9
|
Hybrid Signal Processing Technique to Improve the Defect Estimation in Ultrasonic Non-Destructive Testing of Composite Structures. SENSORS 2017; 17:s17122858. [PMID: 29232845 PMCID: PMC5751725 DOI: 10.3390/s17122858] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 12/06/2017] [Accepted: 12/07/2017] [Indexed: 11/17/2022]
Abstract
This work proposes a novel hybrid signal processing technique to extract information on disbond-type defects from a single B-scan in the process of non-destructive testing (NDT) of glass fiber reinforced plastic (GFRP) material using ultrasonic guided waves (GW). The selected GFRP sample has been a segment of wind turbine blade, which possessed an aerodynamic shape. Two disbond type defects having diameters of 15 mm and 25 mm were artificially constructed on its trailing edge. The experiment has been performed using the low-frequency ultrasonic system developed at the Ultrasound Institute of Kaunas University of Technology and only one side of the sample was accessed. A special configuration of the transmitting and receiving transducers fixed on a movable panel with a separation distance of 50 mm was proposed for recording the ultrasonic guided wave signals at each one-millimeter step along the scanning distance up to 500 mm. Finally, the hybrid signal processing technique comprising the valuable features of the three most promising signal processing techniques: cross-correlation, wavelet transform, and Hilbert–Huang transform has been applied to the received signals for the extraction of defects information from a single B-scan image. The wavelet transform and cross-correlation techniques have been combined in order to extract the approximated size and location of the defects and measurements of time delays. Thereafter, Hilbert–Huang transform has been applied to the wavelet transformed signal to compare the variation of instantaneous frequencies and instantaneous amplitudes of the defect-free and defective signals.
Collapse
|
10
|
Kazys RJ, Sliteris R, Sestoke J. Air-Coupled Ultrasonic Receivers with High Electromechanical Coupling PMN-32%PT Strip-Like Piezoelectric Elements. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2365. [PMID: 29035348 PMCID: PMC5677186 DOI: 10.3390/s17102365] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 10/05/2017] [Accepted: 10/13/2017] [Indexed: 11/17/2022]
Abstract
For improvement of the efficiency of air-coupled ultrasonic transducers PMN-32%PT piezoelectric crystals which possess very high piezoelectric properties may be used. The electromechanical coupling factor of such crystals for all main vibration modes such as the thickness extension and transverse extension modes is more than 0.9. Operation of ultrasonic transducers with such piezoelectric elements in transmitting and receiving modes is rather different. Therefore, for transmission and reception of ultrasonic signals, separate piezoelectric elements with different dimensions must be used. The objective of this research was development of novel air-coupled ultrasonic receivers with PMN-32%PT strip-like piezoelectric elements vibrating in a transverse-extension mode with electromechanically controlled operation and suitable for applications in ultrasonic arrays. Performance of piezoelectric receivers made of the PMN-32%PT strip-like elements vibrating in this mode may be efficiently controlled by selecting geometry of the electrodes covering side surfaces of the piezoelectric element. It is equivalent to introduction of electromechanical damping which does not require any additional backing element. For this purpose; we have proposed the continuous electrodes to divide into two pairs of electrodes. The one pair is used to pick up the electric signal; another one is exploited for electromechanical damping. Two types of electrodes may be used-rectangular or non-rectangular-with a gap between them directed at some angle, usually 45°. The frequency bandwidth is wider (up to 9 kHz) in the case of non-rectangular electrodes. The strip-like acoustic matching element bonded to the tip of the PMN-32%PT crystal may significantly enhance the performance of the ultrasonic receiver. It was proposed to use for this purpose AIREX T10.110 rigid polymer foam, the acoustic impedance of which is close to the optimal value necessary for matching with air. It was found that in order to get a wide bandwidth the length of the matching strip should be selected not a quarter wavelength λ/4 at the antiresonance frequency but at lower frequency. It allowed achieving the frequency bandwidth (14-18)% with respect to the central frequency at -3 dB level.
Collapse
Affiliation(s)
- Rymantas J Kazys
- Ultrasound Institute of Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| | - Reimondas Sliteris
- Ultrasound Institute of Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| | - Justina Sestoke
- Ultrasound Institute of Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
| |
Collapse
|