1
|
Ma C, Zhu Y, Zhang Z, Chen X, Ji Z, Zhang LN, Xu Q. Ratiometric electrochemiluminescence sensing and intracellular imaging of ClO - via resonance energy transfer. Anal Bioanal Chem 2024; 416:4691-4703. [PMID: 38512384 DOI: 10.1007/s00216-024-05236-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 02/24/2024] [Accepted: 02/27/2024] [Indexed: 03/23/2024]
Abstract
Electrochemiluminescence resonance energy transfer (ECL-RET) is a versatile signal transduction strategy widely used in the fabrication of chem/biosensors. However, this technique has not yet been applied in visualized imaging analysis of intracellular species due to the insulating nature of the cell membrane. Here, we construct a ratiometric ECL-RET analytical method for hypochlorite ions (ClO-) by ECL luminophore, with a luminol derivative (L-012) as the donor and a fluorescence probe (fluorescein hydrazide) as the acceptor. L-012 can emit a strong blue ECL signal and fluorescein hydrazide has negligible absorbance and fluorescence signal in the absence of ClO-. Thus, the ECL-RET process is turned off at this time. In the presence of ClO-, however, the closed-loop hydrazide structure in fluorescein hydrazide is opened via specific recognition with ClO-, accompanied with intensified absorbance and fluorescence signal. Thanks to the spectral overlap between the ECL spectrum of L-012 and the absorption spectrum of fluorescein, the ECL-RET effect is gradually recovered with the addition of ClO-. Furthermore, the ECL-RET system has been successfully applied to image intracellular ClO-. Although the insulating nature of the cell itself can generate a shadow ECL pattern in the cellular region, extracellular ECL emission penetrates the cell membrane and excites intracellular fluorescein generated by the reactions between fluorescein hydrazide and ClO-. The cell imaging strategy via ECL-RET circumvents the blocking of the cell membrane and enables assays of intracellular species. The importance of the ECL-RET platform lies in calibrating the fluctuation from the external environment and improving the selectivity by using fluorescent probes. Therefore, this ratiometric ECL sensor has shown broad application prospects in the identification of targets in clinical diagnosis and environmental monitoring.
Collapse
Affiliation(s)
- Cheng Ma
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China.
| | - Yujing Zhu
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China
| | - Zhichen Zhang
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China
| | - Xuan Chen
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China
| | - Zhengping Ji
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China
| | - Lu-Nan Zhang
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, YangzhouJiangsu, 225002, China.
| |
Collapse
|
2
|
Aryal P, Hefner C, Martinez B, Henry CS. Microfluidics in environmental analysis: advancements, challenges, and future prospects for rapid and efficient monitoring. LAB ON A CHIP 2024; 24:1175-1206. [PMID: 38165815 DOI: 10.1039/d3lc00871a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Microfluidic devices have emerged as advantageous tools for detecting environmental contaminants due to their portability, ease of use, cost-effectiveness, and rapid response capabilities. These devices have wide-ranging applications in environmental monitoring of air, water, and soil matrices, and have also been applied to agricultural monitoring. Although several previous reviews have explored microfluidic devices' utility, this paper presents an up-to-date account of the latest advancements in this field for environmental monitoring, looking back at the past five years. In this review, we discuss devices for prominent contaminants such as heavy metals, pesticides, nutrients, microorganisms, per- and polyfluoroalkyl substances (PFAS), etc. We cover numerous detection methods (electrochemical, colorimetric, fluorescent, etc.) and critically assess the current state of microfluidic devices for environmental monitoring, highlighting both their successes and limitations. Moreover, we propose potential strategies to mitigate these limitations and offer valuable insights into future research and development directions.
Collapse
Affiliation(s)
- Prakash Aryal
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Claire Hefner
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Brandaise Martinez
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
3
|
Hajam MI, Khan MM. Microfluidics: a concise review of the history, principles, design, applications, and future outlook. Biomater Sci 2024; 12:218-251. [PMID: 38108438 DOI: 10.1039/d3bm01463k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Microfluidic technologies have garnered significant attention due to their ability to rapidly process samples and precisely manipulate fluids in assays, making them an attractive alternative to conventional experimental methods. With the potential for revolutionary capabilities in the future, this concise review provides readers with insights into the fascinating world of microfluidics. It begins by introducing the subject's historical background, allowing readers to familiarize themselves with the basics. The review then delves into the fundamental principles, discussing the underlying phenomena at play. Additionally, it highlights the different aspects of microfluidic device design, classification, and fabrication. Furthermore, the paper explores various applications, the global market, recent advancements, and challenges in the field. Finally, the review presents a positive outlook on trends and draws lessons to support the future flourishing of microfluidic technologies.
Collapse
Affiliation(s)
- Mohammad Irfan Hajam
- Department of Mechanical Engineering, National Institute of Technology Srinagar, India.
| | - Mohammad Mohsin Khan
- Department of Mechanical Engineering, National Institute of Technology Srinagar, India.
| |
Collapse
|
4
|
McCarthy WP, Srinivas M, Danaher M, Connor CO, Callaghan TFO, van Sinderen D, Kenny J, Tobin JT. Isolation and identification of chlorate-reducing Hafnia sp. from milk. MICROBIOLOGY (READING, ENGLAND) 2023; 169:001347. [PMID: 37450378 PMCID: PMC10433419 DOI: 10.1099/mic.0.001347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 05/31/2023] [Indexed: 07/18/2023]
Abstract
Chlorate has become a concern in the food and beverage sector, related to chlorine sanitizers in industrial food production and water treatment. It is of particular concern to regulatory bodies due to the negative health effects of chlorate exposure. This study investigated the fate of chlorate in raw milk and isolated bacterial strains of interest responsible for chlorate breakdown. Unpasteurized milk was demonstrated to have a chlorate-reducing capacity, breaking down enriched chlorate to undetectable levels in 11 days. Further enrichment and isolation using conditions specific to chlorate-reducing bacteria successfully isolated three distinct strains of Hafnia paralvei. Chlorate-reducing bacteria were observed to grow in a chlorate-enriched medium with lactate as an electron donor. All isolated strains were demonstrated to reduce chlorate in liquid medium; however, the exact mechanism of chlorate degradation was not definitively identified in this study.
Collapse
Affiliation(s)
- William P. McCarthy
- Food Chemistry and Technology Department, Teagasc Food Research Centre, Moorepark, Fermoy, Cork, Ireland
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, Dublin 7, Ireland
| | - Meghana Srinivas
- Food Biosciences Department, Teagasc Food Research Centre, Moorepark, Fermoy, Cork, Ireland
- School of Microbiology, University College Cork, Cork, Ireland
- APC Microbiome Ireland, University College Cork, Cork, Ireland
| | - Martin Danaher
- Food Safety Department, Teagasc Food Research Centre, Ashtown, Dublin 15, Ireland
| | - Christine O. Connor
- School of Food Science and Environmental Health, Technological University Dublin, Grangegorman, Dublin 7, Ireland
| | - Tom F. O. Callaghan
- School of Food and Nutritional Sciences, University College Cork, Cork, Ireland
| | - Douwe van Sinderen
- School of Microbiology, University College Cork, Cork, Ireland
- APC Microbiome Ireland, University College Cork, Cork, Ireland
| | - John Kenny
- Food Biosciences Department, Teagasc Food Research Centre, Moorepark, Fermoy, Cork, Ireland
- VistaMilk Science Foundation Ireland Research Centre, Teagasc, Moorepark, Fermoy, Cork, Ireland
| | - John T. Tobin
- Food Chemistry and Technology Department, Teagasc Food Research Centre, Moorepark, Fermoy, Cork, Ireland
- VistaMilk Science Foundation Ireland Research Centre, Teagasc, Moorepark, Fermoy, Cork, Ireland
| |
Collapse
|
5
|
Vergnes A, Becam J, Loiseau L, Ezraty B. Engineering of a Bacterial Biosensor for the Detection of Chlorate in Food. BIOSENSORS 2023; 13:629. [PMID: 37366994 DOI: 10.3390/bios13060629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/30/2023] [Accepted: 06/02/2023] [Indexed: 06/28/2023]
Abstract
Chlorate can contaminate food due to the use of chlorinated water for processing or equipment disinfection. Chronic exposure to chlorate in food and drinking water is a potential health concern. The current methods for detecting chlorate in liquids and foods are expensive and not easily accessible to all laboratories, highlighting an urgent need for a simple and cost-effective method. The discovery of the adaptation mechanism of Escherichia coli to chlorate stress, which involves the production of the periplasmic Methionine Sulfoxide Reductase (MsrP), prompted us to use an E. coli strain with an msrP-lacZ fusion as a biosensor for detecting chlorate. Our study aimed to optimize the bacterial biosensor's sensitivity and efficiency to detect chlorate in various food samples using synthetic biology and adapted growth conditions. Our results demonstrate successful biosensor enhancement and provide proof of concept for detecting chlorate in food samples.
Collapse
Affiliation(s)
- Alexandra Vergnes
- Aix-Marseille University, CNRS, Laboratoire de Chimie Bactérienne, Institut de Microbiologie de la Méditerranée, 13009 Marseille, France
| | - Jérôme Becam
- Aix-Marseille University, CNRS, Laboratoire de Chimie Bactérienne, Institut de Microbiologie de la Méditerranée, 13009 Marseille, France
| | - Laurent Loiseau
- Aix-Marseille University, CNRS, Laboratoire de Chimie Bactérienne, Institut de Microbiologie de la Méditerranée, 13009 Marseille, France
| | - Benjamin Ezraty
- Aix-Marseille University, CNRS, Laboratoire de Chimie Bactérienne, Institut de Microbiologie de la Méditerranée, 13009 Marseille, France
| |
Collapse
|
6
|
Zhu Y, Wang F. Construction of Digital Economy Trade Security Evaluation System Based on Computational Intelligence. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:5914561. [PMID: 36438682 PMCID: PMC9699732 DOI: 10.1155/2022/5914561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 07/13/2022] [Accepted: 07/27/2022] [Indexed: 07/29/2023]
Abstract
The upgrading of the digital economy (DE) is crucial to building an intelligent society. The rapid development of computational intelligence in recent years has also brought vitality to the development of the DE. However, with the deepening of international trade, the issue of trade security has become more and more prominent. Therefore, this study aimed to construct a DE trade security evaluation system. For computational intelligence, this study proposes a support vector machine based on improved particle swarm optimization. Such an algorithm can play a key role in the construction of an evaluation system. It is built for the evaluation system. This study selects five indicators of market competitiveness, trade control, trade dependence, market concentration, and trade legal system evaluation. The experimental results of this study prove that the evaluation system proposed in this study is effective. In its test for some countries in the world, the UK trade security index was the highest at 0.582, while China was relatively low at 0.492.
Collapse
Affiliation(s)
- Yuqin Zhu
- School of Economics and Management, Hezhou University, Hezhou 542899, Guangxi, China
| | - Fengling Wang
- School of Artificial Intelligence, Hezhou University, Hezhou 542899, Guangxi, China
- School of Data Science, City University of Macau, Macao 999078, Macao, China
| |
Collapse
|
7
|
Heidari-Bafroui H, Kumar A, Charbaji A, Smith W, Rahmani N, Anagnostopoulos C, Faghri M. A Parametric Study on a Paper-Based Bi-Material Cantilever Valve. MICROMACHINES 2022; 13:mi13091502. [PMID: 36144125 PMCID: PMC9506191 DOI: 10.3390/mi13091502] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/05/2022] [Accepted: 09/08/2022] [Indexed: 06/01/2023]
Abstract
The novel paper-based Bi-Material Cantilever (B-MaC) valve allows the autonomous loading and control of multiple fluid reagents which contributes to the accurate operation of paper-based microfluidic devices utilized for biological and chemical sensing applications. In this paper, an extensive parametric study is presented to evaluate the effects of key geometric parameters of the valve, such as paper direction, cantilever width, paper type, tape type, and sample volume, in addition to the effects of relative humidity and temperature on the functionality of the B-MaC and to provide a better understanding of the rate of fluid flow and resulting deflection of the cantilever. Machine direction, cantilever width, paper type, and tape type were found to be important parameters that affect the B-MAC's activation time. It was also observed that the rate of fluid imbibition in the B-MaC is considerably affected by change in humidity for high (55 °C) and low (25 °C) temperatures, while humidity levels have no significant effect during imbibition in the B-MaC at an ambient temperature of 45 °C. It was also found that a minimum distance of 4 mm is required between the B-MaC and the stationary component to prevent accidental activation of the B-MaC prior to sample insertion when relative humidity is higher than 90% and temperature is lower than 35 °C. The rate of fluid imbibition that determines the wetted length of the B-MaC and the final deflection of the cantilever are critical in designing and fabricating point-of-care microfluidic paper-based devices. The B-MaC valve can be utilized in a fluidic circuit to sequentially load several reagents, in addition to the sample to the detection area.
Collapse
|
8
|
Costa-Rama E, Fernández-Abedul MT. Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms. BIOSENSORS 2021; 11:51. [PMID: 33669316 PMCID: PMC7920281 DOI: 10.3390/bios11020051] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Screen-printed technology has helped considerably to the development of portable electrochemical sensors since it provides miniaturized but robust and user-friendly electrodes. Moreover, this technology allows to obtain very versatile transducers, not only regarding their design, but also their ease of modification. Therefore, in the last decades, the use of screen-printed electrodes (SPEs) has exponentially increased, with ceramic as the main substrate. However, with the growing interest in the use of cheap and widely available materials as the basis of analytical devices, paper or other low-cost flat materials have become common substrates for SPEs. Thus, in this revision, a comprehensive overview on paper-based SPEs used for analytical proposes is provided. A great variety of designs is reported, together with several examples to illustrate the main applications.
Collapse
|
9
|
Abstract
Polyoxometalates (POMs) have been used for spectrophotometric determinations of silicon and phosphorus under acidic conditions, referred to as the molybdenum yellow method and molybdenum blue method, respectively. Many POMs are redox active and exhibit fascinating but complicated voltammetric responses. These compounds can reversibly accommodate and release many electrons without exhibiting structural changes, implying that POMs can function as excellent mediators and can be applied to sensitive determination methods based on catalytic electrochemical reactions. In addition, some rare-earth-metal-incorporated POMs exhibit fluorescence, which enables sensitive determination by the enhancement and quenching of fluorescence intensities. In this review, various analytical applications of POMs are introduced, mainly focusing on papers published after 2000, except for the molybdenum yellow method and molybdenum blue method.
Collapse
Affiliation(s)
- Tadaharu Ueda
- Department of Marine Resource Science Faculty of Agriculture and Marine Science, Kochi University, Nankoku, 783-8502, Japan. .,Center for Advanced Marine Core Research, Kochi University, Nankoku, 783-8502, Japan.
| |
Collapse
|
10
|
Charbaji A, Heidari-Bafroui H, Anagnostopoulos C, Faghri M. A New Paper-Based Microfluidic Device for Improved Detection of Nitrate in Water. SENSORS 2020; 21:s21010102. [PMID: 33375290 PMCID: PMC7794956 DOI: 10.3390/s21010102] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 12/06/2020] [Accepted: 12/23/2020] [Indexed: 12/11/2022]
Abstract
In this paper, we report a simple and inexpensive paper-based microfluidic device for detecting nitrate in water. This device incorporates two recent developments in paper-based technology suitable for nitrate detection and has an optimized microfluidic design. The first technical advancement employed is an innovative fibrous composite material made up of cotton fibers and zinc microparticles that can be incorporated in paper-based devices and results in better nitrate reduction. The second is a detection zone with an immobilized reagent that allows the passage of a larger sample volume. Different acids were tested—citric and phosphoric acids gave better results than hydrochloric acid since this acid evaporates completely without leaving any residue behind on paper. Different microfluidic designs that utilize various fluid control technologies were investigated and a design with a folding detection zone was chosen and optimized to improve the uniformity of the signal produced. The optimized design allowed the device to achieve a limit of detection and quantification of 0.53 ppm and 1.18 ppm, respectively, for nitrate in water. This accounted for more than a 40% improvement on what has been previously realized for the detection of nitrate in water using paper-based technology.
Collapse
|
11
|
Forbes TP, Krauss ST, Gillen G. Trace Detection and Chemical Analysis of Homemade Fuel-Oxidizer Mixture Explosives: Emerging Challenges and Perspectives. Trends Analyt Chem 2020; 131:10.1016/j.trac.2020.116023. [PMID: 34135538 PMCID: PMC8201619 DOI: 10.1016/j.trac.2020.116023] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
The chemical analysis of homemade explosives (HMEs) and improvised explosive devices (IEDs) remains challenging for fieldable analytical instrumentation and sensors. Complex explosive fuel-oxidizer mixtures, black and smokeless powders, flash powders, and pyrotechnics often include an array of potential organic and inorganic components that present unique interference and matrix effect difficulties. The widely varying physicochemical properties of these components as well as external environmental interferents and background challenge many sampling and sensing modalities. This review provides perspective on these emerging challenges, critically discusses developments in sampling, sensors, and instrumentation, and showcases advancements for the trace detection of inorganic-based explosives.
Collapse
Affiliation(s)
- Thomas P. Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD 20899, USA
| | - Shannon T. Krauss
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD 20899, USA
| | - Greg Gillen
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD 20899, USA
| |
Collapse
|
12
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Screen-Printed Electrodes: Promising Paper and Wearable Transducers for (Bio)Sensing. BIOSENSORS 2020; 10:E76. [PMID: 32660011 PMCID: PMC7400178 DOI: 10.3390/bios10070076] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 07/05/2020] [Accepted: 07/07/2020] [Indexed: 12/18/2022]
Abstract
Screen-printing technology has revolutionized many fields, including that of electrochemical biosensing. Due to their current relevance, this review, unlike other papers, discusses the relevant aspects of electrochemical biosensors manufactured using this technology in connection to both paper substrates and wearable formats. The main trends, advances, and opportunities provided by these types of devices, with particular attention to the environmental and biomedical fields, are addressed along with illustrative fundamentals and applications of selected representative approaches from the recent literature. The main challenges and future directions to tackle in this research area are also pointed out.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (S.C.); (J.M.P.)
| | | | | |
Collapse
|
13
|
Cytokine and Cancer Biomarkers Detection: The Dawn of Electrochemical Paper-Based Biosensor. SENSORS 2020; 20:s20071854. [PMID: 32230808 PMCID: PMC7180619 DOI: 10.3390/s20071854] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 03/24/2020] [Accepted: 03/24/2020] [Indexed: 12/14/2022]
Abstract
Although the established ELISA-based sensing platforms have many benefits, the importance of cytokine and cancer biomarkers detection for point-of-care diagnostics has propelled the search for more specific, sensitive, simple, accessible, yet economical sensor. Paper-based biosensor holds promise for future in-situ applications and can provide rapid analysis and data without the need to conduct in a laboratory. Electrochemical detection plays a vital role in interpreting results obtained from qualitative assessment to quantitative determination. In this review, various factors affecting the design of an electrochemical paper-based biosensor are highlighted and discussed in depth. Different detection methods, along with the latest development in utilizing them in cytokine and cancer biomarkers detection, are reviewed. Lastly, the fabrication of portable electrochemical paper-based biosensor is ideal in deliberating positive societal implications in developing countries with limited resources and accessibility to healthcare services.
Collapse
|
14
|
Feizy S, Haghighi B. A survey on the effect of ionic liquid on electrochemical behavior and electrocatalytic activity of a phosphomolybdic acid-ionic liquid-MWCNT–modified glassy carbon electrode. J Solid State Electrochem 2019. [DOI: 10.1007/s10008-019-04228-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Meng X, Shi Y, Chen Z, Song L, Zhao M, Zou L, Liu S, Huang W, Zhao Q. Extending Hypochlorite Sensing from Cells to Elesclomol-Treated Tumors in Vivo by Using a Near-Infrared Dual-Phosphorescent Nanoprobe. ACS APPLIED MATERIALS & INTERFACES 2018; 10:35838-35846. [PMID: 30260621 DOI: 10.1021/acsami.8b14717] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Reactive oxygen species (ROS), when beyond the threshold, can exhaust the capacity of cellular antioxidants and ultimately trigger cell apoptosis in tumor biology. However, the roles of hypochlorite (ClO-) in this process are much less clear compared with those of ROS, and its detection is easily obstructed by tissue penetration and endogenous fluorophores. Herein, we first synthesized a near-infrared (NIR) ratiometric ClO- probe (Ir NP) composed of two kinds of phosphorescent iridium(III) complexes (Ir1 and Ir2) encapsulated with amphiphilic DSPE-mPEG5000. Ir NPs are dual-emissive and show obvious changes in phosphorescence intensity ratios and lifetimes of two emission bands upon exposure to ClO-. During the ClO- detection, ratiometric photoluminescence imaging is much more reliable over the intensity-based one for its self-calibration, while time-resolved photoluminescence imaging (TRPI) could distinguish the phosphorescence with long lifetime of Ir NPs from short-lived autofluorescence of tissues, resulting in the high accuracy of ClO- determination. With NIR emission, a long phosphorescence lifetime, fast response, and excellent biocompatibility, Ir NPs were applied to the detection of ClO- in vitro and in vivo by means of ratiometric phosphorescence imaging and TRPI with high signal-to noise-ratios (SNR). Importantly, we demonstrated the elevated ClO- in elesclomol-stimulated tumors in living mice for the first time, which holds great potential for the visualization of the boost of ClO- in anti-carcinogen-treated tumors and the further investigation of ROS-related oncotherapeutics.
Collapse
Affiliation(s)
- Xiangchun Meng
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Yuxiang Shi
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Zejing Chen
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Linna Song
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Menglong Zhao
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Liang Zou
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Shujuan Liu
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| | - Wei Huang
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
- Shaanxi Institute of Flexible Electronics (SIFE) , Northwestern Polytechnical University (NPU) , Xi'an 710072 , Shaanxi , China
| | - Qiang Zhao
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM) , Nanjing University of Posts and Telecommunications (NUPT) , Nanjing 210023 , PR China
| |
Collapse
|
16
|
Hernandez-Vargas G, Sosa-Hernández JE, Saldarriaga-Hernandez S, Villalba-Rodríguez AM, Parra-Saldivar R, Iqbal HMN. Electrochemical Biosensors: A Solution to Pollution Detection with Reference to Environmental Contaminants. BIOSENSORS 2018; 8:E29. [PMID: 29587374 PMCID: PMC6023016 DOI: 10.3390/bios8020029] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Revised: 03/22/2018] [Accepted: 03/23/2018] [Indexed: 02/05/2023]
Abstract
The increasing environmental pollution with particular reference to emerging contaminants, toxic heavy elements, and other hazardous agents is a serious concern worldwide. Considering this global issue, there is an urgent need to design and develop strategic measuring techniques with higher efficacy and precision to detect a broader spectrum of numerous contaminants. The development of precise instruments can further help in real-time and in-process monitoring of the generation and release of environmental pollutants from different industrial sectors. Moreover, real-time monitoring can also reduce the excessive consumption of several harsh chemicals and reagents with an added advantage of on-site determination of contaminant composition prior to discharge into the environment. With key scientific advances, electrochemical biosensors have gained considerable attention to solve this problem. Electrochemical biosensors can be an excellent fit as an analytical tool for monitoring programs to implement legislation. Herein, we reviewed the current trends in the use of electrochemical biosensors as novel tools to detect various contaminant types including toxic heavy elements. A particular emphasis was given to screen-printed electrodes, nanowire sensors, and paper-based biosensors and their role in the pollution detection processes. Towards the end, the work is wrapped up with concluding remarks and future perspectives. In summary, electrochemical biosensors and related areas such as bioelectronics, and (bio)-nanotechnology seem to be growing areas that will have a marked influence on the development of new bio-sensing strategies in future studies.
Collapse
Affiliation(s)
- Gustavo Hernandez-Vargas
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
| | - Juan Eduardo Sosa-Hernández
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
| | - Sara Saldarriaga-Hernandez
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
- Exact and Natural Sciences, Institute of Biology, University of Antioquia, St. 67 No. 53-108, Medellín 050021, Colombia.
| | - Angel M Villalba-Rodríguez
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
| | - Roberto Parra-Saldivar
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
- Microsystems Technologies Laboratories, Massachusetts Institute of Technology (MIT), Cambridge, MA 02139, USA.
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA 02139, USA.
- Harvard-MIT Division of Health Sciences and Technology, MIT, Cambridge, MA 02139, USA.
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Monterrey, Ave. Eugenio Garza Sada 2501, CP 64849, Monterrey, N.L., Mexico.
| |
Collapse
|