1
|
Effects of Braid Angle and Material Modulus on the Negative Poisson’s Ratio of Braided Auxetic Yarns. CRYSTALS 2022. [DOI: 10.3390/cryst12060781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Fibers and textiles are ubiquitous in our daily lives, with mechanical properties that match the design specifications for the task for which they are intended; the development of yarns with a negative Poisson’s ratio (NPR) is a hot topic of current research, owing to their potential for use in high-performance textiles (e.g., military, sports, etc.). This study described a simple approach to constructing braided, helically interlaced yarns. When a torque is applied, the yarns prevent the wrapped component from dislodging from the core. The geometry and auxetic behavior of the braided helical structure was analyzed for two different combinations of core materials with similar wrap materials and different braiding angles. Two elastomeric materials (polyurethane (PU) and polyester) served as monofilament cores, while two stiffer multifilament wrap yarns (ultrahigh molecular weight polyethylene (UHMWPE) and polyethylene terephthalate (PET)) served as wrap yarns. In addition, the behavior of yarns braided at seven different angles was investigated to determine the materials’ response to the applied braided configuration’s NPR. The NPR was influenced by the core and wrap materials used and the braiding angle. The NPR value was greater for a core comprising more excellent elasticity (e.g., PU versus polyester); a smaller wrap angle and a slower braiding speed also led to a higher NPR value. The maximum NPR value of −1.70 was obtained using a PU core wrapped at a 9° angle and a strain value of 0.5.
Collapse
|
2
|
Liu H, Laflamme S, Zellner EM, Aertsens A, Bentil SA, Rivero IV, Secord TW. Soft Elastomeric Capacitor for Strain and Stress Monitoring on Sutured Skin Tissues. ACS Sens 2021; 6:3706-3714. [PMID: 34582189 DOI: 10.1021/acssensors.1c01477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Sutures are ubiquitous medical devices for wound closures in human and veterinary medicine, and suture techniques are frequently evaluated by comparing tensile strengths in ex vivo studies. Direct and nondestructive measurement of tensile force present in sutured biological skin tissue is a key challenge in biomechanical fields because of the unique and complex properties of each sutured skin specimen and the lack of compliant sensors capable of monitoring large levels of strain. The authors have recently proposed a soft elastomeric capacitor (SEC) sensor that consists of a highly compliant and scalable strain gauge capable of transducing geometric variations into a measurable change in capacitance. In this study, corrugated SECs are used to experimentally characterize the inherent biomechanical properties of canine skin specimens. In particular, an SEC corrugated with a re-entrant hexagonal honeycomb pattern is studied to monitor strain and stresses for three specific suture patterns: simple interrupted, cruciate, and intradermal patterns. Stress is estimated using constitutive models based on the Fractional Zener and the Kelvin-Voigt models, parametrized using a particle swarm algorithm from experimental data and results from a validated finite element model. Results are benchmarked against findings from the literature and show that SECs are valuable for clinical evaluation of tensile force in biological skins. It was found that both the ranking of suture pattern performance and the sutured skin's Young's modulus using the proposed approach agreed with data reported in the literature and that the estimated stress at the suture level closely matched that of an approximate finite element model.
Collapse
Affiliation(s)
- Han Liu
- Department of Civil, Construction and Environmental Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Simon Laflamme
- Department of Civil, Construction and Environmental Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Eric M. Zellner
- Veterinary Clinical Sciences, Iowa State University, Ames, Iowa 50011, United States
| | - Adrien Aertsens
- Veterinary Clinical Sciences, Iowa State University, Ames, Iowa 50011, United States
| | - Sarah A. Bentil
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Iris V. Rivero
- Department of Industrial and Systems Engineering, Rochester Institute of Technology, Rochester, New York 14623, United States
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, New York 14623, United States
| | - Thomas W. Secord
- Department of Mechanical Engineering, University of St. Thomas, St. Paul, Minnesota 55105, United States
| |
Collapse
|