1
|
Czajkowska A, Korsak D, Fiedoruk-Pogrebniak M, Koncki R, Strzelak K. Turbidimetric flow analysis system for the investigation of microbial growth. Talanta 2024; 268:125303. [PMID: 37852015 DOI: 10.1016/j.talanta.2023.125303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/03/2023] [Accepted: 10/07/2023] [Indexed: 10/20/2023]
Abstract
The monitoring of life of microbial populations is of the uttermost importance in environmental and food analysis, agriculture, as well as in medicine. The duration of bacteria adaptation to new environmental conditions, its lifetime and the divisions' pace are the key information in many studies. It was found that the fully-mechanized flow analysis system based on solenoid valves and pumps, paired with a dedicated flow-through optoelectronic detector can be successfully applied for monitoring of bacteria growth. The applicability of the designed multicommutated flow analysis (MCFA) system was proved by analysis of solutions containing bacteria cells proceeded by tests of McFarland (McF) standards. The developed setup allowed modelling and simulation of microbial growth, as well as monitoring of the bacteria growth in real-time manner to be carried out. The monitor is useful for the quantitative estimation of the basic parameters of bacteria population like its size, the rate of bacteria multiplication, as well as the times of lag, log and stationary phases of microbial growth.
Collapse
Affiliation(s)
| | - Dorota Korsak
- Faculty of Biology, University of Warsaw, Warsaw, Poland
| | | | - Robert Koncki
- Faculty of Chemistry, University of Warsaw, Warsaw, Poland
| | - Kamil Strzelak
- Faculty of Chemistry, University of Warsaw, Warsaw, Poland.
| |
Collapse
|
2
|
Liu Z, Su J, Zhou K, Yu B, Lin Y, Li KH. Fully Integrated Patch Based on Lamellar Porous Film Assisted GaN Optopairs for Wireless Intelligent Respiratory Monitoring. NANO LETTERS 2023; 23:10674-10681. [PMID: 37712616 DOI: 10.1021/acs.nanolett.3c02071] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Respiratory pattern is one of the most crucial indicators for accessing human health, but there has been limited success in implementing fast-responsive, affordable, and miniaturized platforms with the capability for smart recognition. Herein, a fully integrated and flexible patch for wireless intelligent respiratory monitoring based on a lamellar porous film functionalized GaN optoelectronic chip with a desirable response to relative humidity (RH) variation is reported. The submillimeter-sized GaN device exhibits a high sensitivity of 13.2 nA/%RH at 2-70%RH and 61.5 nA/%RH at 70-90%RH, and a fast response/recovery time of 12.5 s/6 s. With the integration of a wireless data transmission module and the assistance of machine learning based on 1-D convolutional neural networks, seven breathing patterns are identified with an overall classification accuracy of >96%. This integrated and flexible on-mask sensing platform successfully demonstrates real-time and intelligent respiratory monitoring capability, showing great promise for practical healthcare applications.
Collapse
Affiliation(s)
- Zecong Liu
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| | - Junjie Su
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| | - Kemeng Zhou
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| | - Binlu Yu
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| | - Yuanjing Lin
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| | - Kwai Hei Li
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, P.R. China
| |
Collapse
|
3
|
Tovar-Lopez FJ. Recent Progress in Micro- and Nanotechnology-Enabled Sensors for Biomedical and Environmental Challenges. SENSORS (BASEL, SWITZERLAND) 2023; 23:5406. [PMID: 37420577 DOI: 10.3390/s23125406] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/01/2023] [Accepted: 06/05/2023] [Indexed: 07/09/2023]
Abstract
Micro- and nanotechnology-enabled sensors have made remarkable advancements in the fields of biomedicine and the environment, enabling the sensitive and selective detection and quantification of diverse analytes. In biomedicine, these sensors have facilitated disease diagnosis, drug discovery, and point-of-care devices. In environmental monitoring, they have played a crucial role in assessing air, water, and soil quality, as well as ensured food safety. Despite notable progress, numerous challenges persist. This review article addresses recent developments in micro- and nanotechnology-enabled sensors for biomedical and environmental challenges, focusing on enhancing basic sensing techniques through micro/nanotechnology. Additionally, it explores the applications of these sensors in addressing current challenges in both biomedical and environmental domains. The article concludes by emphasizing the need for further research to expand the detection capabilities of sensors/devices, enhance sensitivity and selectivity, integrate wireless communication and energy-harvesting technologies, and optimize sample preparation, material selection, and automated components for sensor design, fabrication, and characterization.
Collapse
|
4
|
Rocher J, Jimenez JM, Tomas J, Lloret J. Low-Cost Turbidity Sensor to Determine Eutrophication in Water Bodies. SENSORS (BASEL, SWITZERLAND) 2023; 23:3913. [PMID: 37112254 PMCID: PMC10143286 DOI: 10.3390/s23083913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/04/2023] [Accepted: 04/05/2023] [Indexed: 06/19/2023]
Abstract
Eutrophication is the excessive growth of algae in water bodies that causes biodiversity loss, reducing water quality and attractiveness to people. This is an important problem in water bodies. In this paper, we propose a low-cost sensor to monitor eutrophication in concentrations between 0 to 200 mg/L and in different mixtures of sediment and algae (0, 20, 40, 60, 80, and 100% algae, the rest are sediment). We use two light sources (infrared and RGB LED) and two photoreceptors at 90° and 180° of the light sources. The system has a microcontroller (M5stacks) that powers the light sources and obtains the signal received by the photoreceptors. In addition, the microcontroller is responsible for sending information and generating alerts. Our results show that the use of infrared light at 90° can determine the turbidity with an error of 7.45% in NTU readings higher than 2.73 NTUs, and the use of infrared light at 180° can measure the solid concentration with an error of 11.40%. According to the determination of the % of algae, the use of a neural network has a precision of 89.3% in the classification, and the determination of the mg/L of algae in water has an error of 17.95%.
Collapse
|
5
|
Sanchez R, Groc M, Vuillemin R, Pujo-Pay M, Raimbault V. Development of a Frugal, In Situ Sensor Implementing a Ratiometric Method for Continuous Monitoring of Turbidity in Natural Waters. SENSORS (BASEL, SWITZERLAND) 2023; 23:1897. [PMID: 36850493 PMCID: PMC9962470 DOI: 10.3390/s23041897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Turbidity is a commonly used indicator of water quality in continental and marine waters and is mostly caused by suspended and colloidal particles such as organic and inorganic particles. Many methods are available for the measurement of turbidity, ranging from the Secchi disk to infrared light-based benchtop or in situ turbidimeters as well as acoustic methods. The operational methodologies of the large majority of turbidity instruments involve the physics of light scattering and absorption by suspended particles when light is passed through a sample. As such, in the case of in situ monitoring in water bodies, the measurement of turbidity is highly influenced by external light and biofouling. Our motivation for this project is to propose an open-source, low-cost in situ turbidity sensor with a suitable sensitivity and operating range to operate in low-to-medium-turbidity natural waters. This prototype device combines two angular photodetectors and two infrared light sources with different positions, resulting in two different types of light detection, namely nephelometric (i.e., scattering) and attenuation light, according to the ISO 7027 method. The mechanical design involves 3D-printed parts by stereolithography, which are compatible with commercially available waterproof enclosures, thus ensuring easy integration for future users. An effort was made to rely on mostly off-the-shelf electronic components to encourage replication of the system, with the use of a highly integrated photometric front-end commonly used in portable photoplethysmography systems. The sensor was tested in laboratory conditions against a commercial benchtop turbidimeter with Formazin standards. The monitoring results were analyzed, obtaining a linear trendline from 0 to 50 Nephelometric Turbidity Unit (NTU) and an accuracy of +/-0.4 NTU in the 0 to 10 NTU range with a response time of less than 100 ms.
Collapse
Affiliation(s)
- Raul Sanchez
- LAAS-CNRS, Université de Toulouse, CNRS, 31400 Toulouse, France
| | - Michel Groc
- Sorbonne Université, CNRS, FR3724, Observatoire Océanologique de Banyuls, 66651 Banyuls-sur-Mer, France
| | - Renaud Vuillemin
- Sorbonne Université, CNRS, FR3724, Observatoire Océanologique de Banyuls, 66651 Banyuls-sur-Mer, France
| | - Mireille Pujo-Pay
- Sorbonne Université, CNRS, UMR7621, Laboratoire d’Océanographie Microbienne (LOMIC), 66651 Banyuls-sur-Mer, France
| | | |
Collapse
|
6
|
Fernandes S, Tlemçani M, Bortoli D, Feliciano M, Lopes ME. A Portable Measurement Device Based on Phenanthroline Complex for Iron Determination in Water. SENSORS (BASEL, SWITZERLAND) 2023; 23:1058. [PMID: 36772098 PMCID: PMC9919581 DOI: 10.3390/s23031058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 01/10/2023] [Accepted: 01/12/2023] [Indexed: 06/18/2023]
Abstract
In this work, a newly developed self-contained, portable, and compact iron measurement system (IMS) based on spectroscopy absorption for determination of Fe2+ in water is presented. One of the main goals of the IMS is to operate the device in the field as opposed to instruments commonly used exclusively in the laboratory. In addition, the system has been tuned to quantify iron concentrations in accordance with the values proposed by the regulations for human consumption. The instrument uses the phenanthroline standard method for iron determination in water samples. This device is equipped with an optical sensing system consisting of a light-emitting diode paired with a photodiode to measure absorption radiation through ferroin complex medium. To assess the sensor response, four series of Fe2+ standard samples were prepared with different iron concentrations in various water matrices. Furthermore, a new solid reagent prepared in-house was investigated, which is intended as a "ready-to-use" sample pre-treatment that optimizes work in the field. The IMS showed better analytical performance compared with the state-of-the-art instrument. The sensitivity of the instrument was found to be 2.5 µg Fe2+/L for the measurement range established by the regulations. The linear response of the photodiode was determined for concentrations between 25 and 1000 µg Fe2+/L, making this device suitable for assessing iron in water bodies.
Collapse
Affiliation(s)
- Samuel Fernandes
- Department of Mechatronics Engineering, School of Science and Technology, Universidade de Évora, 7000-671 Évora, Portugal
- Instrumentation and Control Laboratory (ICL), Insititute of Earth Sciences (ICT), Universidade de Évora, 7000-671 Évora, Portugal
| | - Mouhaydine Tlemçani
- Department of Mechatronics Engineering, School of Science and Technology, Universidade de Évora, 7000-671 Évora, Portugal
- Instrumentation and Control Laboratory (ICL), Insititute of Earth Sciences (ICT), Universidade de Évora, 7000-671 Évora, Portugal
| | - Daniele Bortoli
- Instrumentation and Control Laboratory (ICL), Insititute of Earth Sciences (ICT), Universidade de Évora, 7000-671 Évora, Portugal
- Physics Department, School of Science and Technology (ECT), Universidade de Évora, 7000-671 Évora, Portugal
- Earth Remote Sensing Laboratory (EaRSLab), Institute of Earth Sciences (ICT), Universidade de Évora, 7000-671 Évora, Portugal
| | - Manuel Feliciano
- Centro de Investigação de Montanha (CIMO), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
- Laboratório Associado para a Sustentabilidade e Tecnologia em Regiões de Montanha (SusTEC), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
| | - Maria Elmina Lopes
- Department of Chemistry and Biochemistry, School of Science and Technology (ECT), Universidade de Évora, 7000-671 Evora, Portugal
| |
Collapse
|
7
|
Fay CD, Nattestad A. LED PEDD Discharge Photometry: Effects of Software Driven Measurements for Sensing Applications. SENSORS 2022; 22:s22041526. [PMID: 35214426 PMCID: PMC8879031 DOI: 10.3390/s22041526] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 02/03/2022] [Accepted: 02/04/2022] [Indexed: 11/29/2022]
Abstract
This work explores the effects of embedded software-driven measurements on a sensory target when using a LED as a photodetector. Water turbidity is used as the sensory target in this study to explore these effects using a practical and important water quality parameter. Impacts on turbidity measurements are examined by adopting the Paired Emitter Detector Diode (PEDD) capacitive discharge technique and comparing common embedded software/firmware implementations. The findings show that the chosen software method can (a) affect the detection performance by up to 67%, (b) result in a variable sampling frequency/period, and (c) lead to an disagreement of the photo capacitance by up to 23%. Optimized code is offered to correct for these issues and its effectiveness is shown through comparative analyses, with the disagreement reduced significantly from 23% to 0.18%. Overall, this work demonstrates that the embedded software is a key and critical factor for PEDD capacitive discharge measurements and must be considered carefully for future measurements in sensor related studies.
Collapse
Affiliation(s)
- Cormac D. Fay
- SMART Infrastructure Facility, Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia
- Correspondence:
| | - Andrew Nattestad
- School of Chemistry, Monash University, Clayton, VIC 3800, Australia; or
- Intelligent Polymer Research Institute, AIIM Facility, University of Wollongong, Wollongong, NSW 2522, Australia
| |
Collapse
|