1
|
Kreve S, Ferreira I, da Costa Valente ML, Dos Reis AC. Relationship between dental implant macro-design and osseointegration: a systematic review. Oral Maxillofac Surg 2024; 28:1-14. [PMID: 36171302 DOI: 10.1007/s10006-022-01116-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 09/17/2022] [Indexed: 10/14/2022]
Abstract
PURPOSE This systematic review aimed to determine whether differences in the macro-geometry of titanium implants promote changes in osseointegration. MATERIAL AND METHOD SCOPUS, PubMed/Medline, Web of Science, and EMBASE databases were searched in June 2021. In addition, it was performed a manual search of the reference lists of the included articles. Eligibility criteria were in vivo studies that addressed the effect of titanium implant macro-geometry on osseointegration, studies that evaluated periodontally healthy models, and papers indexed in Journal Citation Reports. RESULTS The database search resulted in 1037 articles. Of the 19 articles selected for full reading, 16 remained in this systematic review. These had a high heterogeneity making it hard to perform statistical analysis of the data, so a descriptive analysis was performed. CONCLUSIONS Based on the studies included in this systematic review, implant macro-geometry provides influences on osseointegration. In this sense, the various isolated characteristics (thread type, thread pitch, thread depth, face angle) should be studied so that the implant geometry can balance the compressive stress and tensile stress and produce a minimum shear force.
Collapse
Affiliation(s)
- Simone Kreve
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. do Café, s/n 14040-904, Ribeirão Preto, SP, Brazil
| | - Izabela Ferreira
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. do Café, s/n 14040-904, Ribeirão Preto, SP, Brazil
| | - Mariana Lima da Costa Valente
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. do Café, s/n 14040-904, Ribeirão Preto, SP, Brazil
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, USP-University of São Paulo, Av. do Café, s/n 14040-904, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
2
|
Khaohoen A, Sornsuwan T, Chaijareenont P, Poovarodom P, Rungsiyakull C, Rungsiyakull P. Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review. J Clin Med 2023; 12:6924. [PMID: 37959389 PMCID: PMC10649288 DOI: 10.3390/jcm12216924] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/15/2023] Open
Abstract
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting's bone state.
Collapse
Affiliation(s)
- Angkoon Khaohoen
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Tanapon Sornsuwan
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok 65000, Thailand;
| | - Pisaisit Chaijareenont
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| |
Collapse
|
3
|
Heimes D, Becker P, Pabst A, Smeets R, Kraus A, Hartmann A, Sagheb K, Kämmerer PW. How does dental implant macrogeometry affect primary implant stability? A narrative review. Int J Implant Dent 2023; 9:20. [PMID: 37405709 DOI: 10.1186/s40729-023-00485-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 06/21/2023] [Indexed: 07/06/2023] Open
Abstract
PURPOSE The macrogeometry of a dental implant plays a decisive role in its primary stability. A larger diameter, a conical shape, and a roughened surface increase the contact area of the implant with the surrounding bone and thus improve primary stability. This is considered the basis for successful implant osseointegration that different factors, such as implant design, can influence. This narrative review aims to critically review macro-geometric features affecting the primary stability of dental implants. METHODS For this review, a comprehensive literature search and review of relevant studies was conducted based on formulating a research question, searching the literature using keywords and electronic databases such as PubMed, Embase, and Cochrane Library to search for relevant studies. These studies were screened and selected, the study quality was assessed, data were extracted, the results were summarized, and conclusions were drawn. RESULTS The macrogeometry of a dental implant includes its surface characteristics, size, and shape, all of which play a critical role in its primary stability. At the time of placement, the initial stability of an implant is determined by its contact area with the surrounding bone. Larger diameter and a conical shape of an implant result in a larger contact area and better primary stability. But the linear relationship between implant length and primary stability ends at 12 mm. CONCLUSIONS Several factors must be considered when choosing the ideal implant geometry, including local factors such as the condition of the bone and soft tissues at the implant site and systemic and patient-specific factors such as osteoporosis, diabetes, or autoimmune diseases. These factors can affect the success of the implant procedure and the long-term stability of an implant. By considering these factors, the surgeon can ensure the greatest possible therapeutic success and minimize the risk of implant failure.
Collapse
Affiliation(s)
- Diana Heimes
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| | - Philipp Becker
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Department of Oral and Maxillofacial Surgery, Federal Armed Forces Hospital, Rübenacherstraße 170, 56072, Koblenz, Germany
| | - Andreas Pabst
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Department of Oral and Maxillofacial Surgery, Federal Armed Forces Hospital, Rübenacherstraße 170, 56072, Koblenz, Germany
| | - Ralf Smeets
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
- Department of Oral and Maxillofacial Surgery, Division of "Regenerative Orofacial Medicine", University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Annika Kraus
- Department of Prosthetic Dentistry, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Amely Hartmann
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Private Practice for Oral Surgery, Echterdinger Straße 7, 70794, Filderstadt, Germany
| | - Keyvan Sagheb
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| |
Collapse
|
4
|
de Carvalho Formiga M, da Silva HDP, Ghiraldini B, Siroma RS, Ardelean LC, Piattelli A, Shibli JA. Effects of Osseodensification on Primary Stability of Cylindrical and Conical Implants-An Ex Vivo Study. J Clin Med 2023; 12:jcm12113736. [PMID: 37297938 DOI: 10.3390/jcm12113736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/23/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
Primary stability is an important factor for dental implant success. In the past years, a new method for bone site preparation was introduced, named osseodensification (OD). OD produces a condensation of the trabecular portion of the bone, increasing bone-to-implant contact and primary stability. This study aims to compare the effect of OD in cylindrical and conical implants to conventional instrumentation. A total of forty implants, divided into four groups, were placed in porcine tibia: cylindrical conventional (1a), cylindrical OD (1b), conical conventional (2a) and conical OD (2b). Each implant was measured for implant stability quotient (ISQ), insertion torque (IT) and removal torque (RT). Group 2b showed the higher values for each of the evaluated parameters; groups 1b and 2b showed better results than 1a and 2a, respectively. Regarding the IT and RT, group 1b achieved higher values than group 2a, but not for ISQ. The inter-group comparison showed significant difference between groups 1a vs 2a, 1a vs 2b and 1b vs 2b for ISQ and 1a vs 1b and 1a vs 2b for RT analysis. OD resulted in improved ISQ, IT and RT of both cylindrical and conical implants.
Collapse
Affiliation(s)
- Márcio de Carvalho Formiga
- Department of Periodontology and Oral Implantology, Unisul, Palhoça, 515 Felipe Schmidt Str., Florianopolis 88101-001, SC, Brazil
- Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 88 Praça Tereza Cristina Sq., Guarulhos 07011-010, SC, Brazil
| | - Helio Doyle Pereira da Silva
- Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 88 Praça Tereza Cristina Sq., Guarulhos 07011-010, SC, Brazil
| | - Bruna Ghiraldini
- Dental Research Division, Paulista University, 303 Borges de Figueiredo Str., São Paulo 03110-010, SP, Brazil
| | - Rafael Shinoske Siroma
- Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 88 Praça Tereza Cristina Sq., Guarulhos 07011-010, SC, Brazil
| | - Lavinia Cosmina Ardelean
- Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, "Victor Babes" University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Adriano Piattelli
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, 332 Viale Abruzzo Str., 66100 Chieti, Italy
| | - Jamil Awad Shibli
- Department of Periodontology and Oral Implantology, Dental Research Division, Guarulhos University, 88 Praça Tereza Cristina Sq., Guarulhos 07011-010, SC, Brazil
| |
Collapse
|
5
|
Gehrke SA, Júnior JA, Treichel TLE, do Prado TD, Dedavid BA, de Aza PN. Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles. Sci Rep 2022; 12:538. [PMID: 35017552 PMCID: PMC8752839 DOI: 10.1038/s41598-021-04313-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 12/14/2021] [Indexed: 12/15/2022] Open
Abstract
The aim of the present in vivo study was to analyze and compare the effects on the crestal bone healing of two different implant macrogeometries installed in fresh socket areas and in normal bone areas with different insertion torque values. Two implant macrogeometries were used in the present study, DuoCone implant (DC) and Maestro implant (MAE), forming four groups: group DCws, in which the implants were installed in healing bone (without a socket); group DCfs, in which the implants were installed in post-extraction areas (fresh sockets); group MAEws, in which the implants were installed in healing bone (without a socket); group MAEfs, in which the implants were installed in post-extraction areas (fresh sockets). After 30 and 90 days of implantations in the bilateral mandibles of 10 sheep, eighty implants were evaluated through digital X-ray images and histologic slices. The crestal bone position in relation to the implant platform shoulder was measured and compared. The measured insertion torque was 47.2 ± 4.69 Ncm for the DCws group, 43.4 ± 4.87 Ncm for the DCfs group, 29.3 ± 3.16 Ncm for the MAEws group, and 27.7 ± 4.41 Ncm for the MAEfs group. The radiographic mesio-distal and histological bucco-lingual analyses showed significantly greater vertical bone loss in the implants installed with high torque (DC groups) in comparison to the implants installed with a low torque (MAE groups) (p < 0.05), at both evaluation times. In general, low insertion torque values (Maestro implants) showed better results of MBL when compared to implants installed with higher torque values (Duo Cone implants). Moreover, our results showed that the implants installed in the sites without sockets showed a less MBL in comparison with the implants installed in sites of fresh sockets.
Collapse
Affiliation(s)
- Sergio Alexandre Gehrke
- Department of Biotechnology, Universidad Católica de Murcia, 30107, Murcia, Spain.
- Department of Research, Biotecnos - Technology and Science, Cuareim 1483, 11100, Montevideo, Uruguay.
| | | | | | - Tales Dias do Prado
- Department of Surgery, Faculty of Medicine Veterinary, University of Rio Verde, Rio Verde, Brazil
| | - Berenice Anina Dedavid
- Department of Materials Engineering, Pontificia Universidade Católica do Rio Grande do Sul, Porto Alegre, 90619-900, Brazil
| | - Piedad N de Aza
- Department of Materials, Instituto de Bioingenieria, Universidad Miguel Hernández, Elche, Alicante, Spain
| |
Collapse
|