1
|
Edsall C, Huynh L, Mustafa W, Hall TL, Durmaz YY, Vlaisavljevich E. Nanoparticle-Mediated Histotripsy Using Dual-Frequency Pulsing Methods. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:1214-1223. [PMID: 38797630 DOI: 10.1016/j.ultrasmedbio.2024.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 04/19/2024] [Accepted: 04/21/2024] [Indexed: 05/29/2024]
Abstract
OBJECTIVE Nanoparticle-mediated histotripsy (NMH) is a novel ablation method that combines nanoparticles as artificial cavitation nuclei with focused ultrasound pulsing to achieve targeted, non-invasive, and cell-selective tumor ablation. The study described here examined the effect of dual-frequency histotripsy pulsing on the cavitation threshold, bubble cloud characteristics, and ablative efficiency in NMH. High-speed optical imaging was used to analyze bubble cloud characteristics and to measure ablation efficiency for NMH inside agarose tissue phantoms containing perfluorohexane-filled nanocone clusters, which were previously developed to reduce the histotripsy cavitation threshold for NMH. METHODS Dual-frequency histotripsy pulsing was applied at a 1:1 pressure ratio using a modular 500 kHz and 3 MHz dual-frequency array transducer. Optical imaging results revealed predictable, well-defined bubble clouds generated for all tested cases with similar reductions in the cavitation thresholds observed for single-frequency and dual-frequency pulsing. RESULTS Dual-frequency pulsing was seen to nucleate small, dense clouds in agarose phantoms, intermediate in size of their component frequencies but closer in area to that of the higher component frequency. Red blood cell experiments revealed complete ablations were generated by dual-frequency NMH in all phantoms in <1500 pulses. This result was a significant increase in ablation efficiency compared with the ∼4000 pulses required in prior single-frequency NMH studies. CONCLUSION Overall, this study indicates the potential for using dual-frequency histotripsy methods to increase the ablation efficacy of NMH.
Collapse
Affiliation(s)
- Connor Edsall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA.
| | - Laura Huynh
- Department of Materials Science and Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Waleed Mustafa
- Department of Biomedical Engineering, Istanbul Medipol University, İstanbul, Turkey
| | - Timothy L Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Yasemin Yuksel Durmaz
- Department of Biomedical Engineering, Istanbul Medipol University, İstanbul, Turkey; Research Institute of Health Science and Technologies (SABITA), Istanbul Medipol University, Istanbul, Turkey
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA; ICTAS Center for Engineered Health, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| |
Collapse
|
2
|
Zhu Y, Zhang G, Zhang Q, Luo L, Ding B, Guo X, Zhang D, Tu J. Real-time passive cavitation mapping and B-mode fusion imaging via hybrid adaptive beamformer with modified diagnostic ultrasound platform. ULTRASONICS 2024; 142:107375. [PMID: 38901152 DOI: 10.1016/j.ultras.2024.107375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2024] [Revised: 05/15/2024] [Accepted: 06/06/2024] [Indexed: 06/22/2024]
Abstract
The implementation of real-time, convenient and high-resolution passive cavitation imaging (PCM) is crucial for ensuring the safety and effectiveness of ultrasound applications related to cavitation effects. However, the current B-mode ultrasound imaging system cannot achieve these functions. By developing a hybrid adaptive beamforming algorithm, the current work presented a real-time PCM and B-mode fusion imaging technique, using a modified diagnostic ultrasound platform enabling time-division multiplexing external triggering function. The proposed hybrid adaptive beamformer combined the advantages of delay-multiply-and-sum (DMAS) and minimum variance (MV) methods to effectively suppress the side lobe and tail-like artifacts, improving the resolution of PCM images. A high-pass filter was applied to selectively detect cavitation-specific signals while removing the interference from the tissue scatters. The system enabled synchronous visualization of tissue structure and cavitation activity under ultrasound exposure. Both numerical and experimental studies demonstrated that, compared with DAS, MV-DAS and DMAS methods, the proposed MV-DMAS algorithm performed better in both axial and lateral resolutions. This work represented a significant advancement in achieving high-quality real-time B-mode and PCM fusion imaging utilizing commercial medical ultrasound system, providing a powerful tool for synchronous monitoring and manipulating cavitation activity, which would enhance the safety and efficacy of cavitation-based applications.
Collapse
Affiliation(s)
- Yifei Zhu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Guofeng Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Qi Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Lan Luo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Bo Ding
- Zhuhai Ecare Electronics Science & Technology Co., Ltd., Zhuhai 519041, China
| | - Xiasheng Guo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Dong Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| | - Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| |
Collapse
|
3
|
Simon A, Edsall C, Maxwell A, Vlaisavljevich E. Effects of pulse repetition frequency on bubble cloud characteristics and ablation in single-cycle histotripsy. Phys Med Biol 2024; 69:025018. [PMID: 38041873 DOI: 10.1088/1361-6560/ad11a1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 12/01/2023] [Indexed: 12/04/2023]
Abstract
Objective. Histotripsy is a cavitation-based ultrasound ablation method in development for multiple clinical applications. This work investigates the effects of pulse repetition frequency (PRF) on bubble cloud characteristics and ablative capabilities for histotripsy using single-cycle pulsing methods.Approach.Bubble clouds produced by a 500 kHz histotripsy system at PRFs from 0.1 to 1000 Hz were visualized using high-speed optical imaging in 1% agarose tissue phantoms at peak negative pressures,p-, of 2-36 MPa.Main results.Results showed a decrease in the cavitation cloud threshold with increasing PRF, ranging from 26.7 ± 0.5 MPa at 0.1 Hz to 15.0 ± 1.9 MPa at 1000 Hz. Bubble cloud analysis showed cavitation clouds generated at low PRFs (0.1-1 Hz) were characterized by consistently dense bubble clouds (41.7 ± 2.8 bubbles mm-2at 0.1 Hz), that closely matched regions of the focus above the histotripsy intrinsic threshold. Bubble clouds formed at higher PRFs measured lower cloud densities (23.1 ± 4.0 bubbles mm-2at 1000 Hz), with the lowest density measured for 10 Hz (8.8 ± 4.1 bubbles mm-2). Furthermore, higher PRFs showed increased pulse-to-pulse correlation, characteristic of cavitation memory effects; however, bubble clouds still filled the entire volume of the focus due to their initial density and enhanced bubble expansion from the restimulation of residual nuclei at the higher PRFs. Histotripsy ablation assessed through lesion analysis in red blood cell (RBC) phantoms showed higher PRFs generated lesions with lower adherence to the initial focal region compared to low PRF ablations; however, no trend of decreasing ablation efficiency with PRF was observed, with similar efficiencies observed for all the PRFs tested in this study.Significance.Notably, this result is different than what has previously been shown for shock-scattering histotripsy, which has shown decreased ablation efficiencies at higher PRFs. Overall, this study demonstrates the essential effects of PRF on single-cycle histotripsy procedures that should be considered to help guide future histotripsy pulsing strategies.
Collapse
Affiliation(s)
- Alex Simon
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, United States of America
| | - Connor Edsall
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, United States of America
| | - Adam Maxwell
- Department of Urology, University of Washington, Seattle, WA, United States of America
| | - Eli Vlaisavljevich
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, United States of America
| |
Collapse
|
4
|
Morse R, Childers C, Nowak E, Rao J, Vlaisavljevich E. Catheter-Based Medical Device Biofilm Ablation Using Histotripsy: A Parameter Study. ULTRASOUND IN MEDICINE & BIOLOGY 2023:S0301-5629(23)00203-X. [PMID: 37394375 DOI: 10.1016/j.ultrasmedbio.2023.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/07/2023] [Accepted: 06/13/2023] [Indexed: 07/04/2023]
Abstract
OBJECTIVE Biofilm formation in medical catheters is a major source of hospital-acquired infections which can produce increased morbidity and mortality for patients. Histotripsy is a non-invasive, non-thermal focused ultrasound therapy and recently has been found to be effective at removal of biofilm from medical catheters. Previously established histotripsy methods for biofilm removal, however, would require several hours of use to effectively treat a full-length medical catheter. Here, we investigate the potential to increase the speed and efficiency with which biofilms can be ablated from catheters using histotripsy. METHODS Pseudomonas aeruginosa (PA14) biofilms were cultured in in vitro Tygon catheter mimics and treated with histotripsy using a 1 MHz histotripsy transducer and a variety of histotripsy pulsing rates and scanning methods. The improved parameters identified in these studies were then used to explore the bactericidal effect of histotripsy on planktonic PA14 suspended in a catheter mimic. RESULTS Histotripsy can be used to remove biofilm and kill bacteria at substantially increased speeds compared with previously established methods. Near-complete biofilm removal was achieved at treatment speeds up to 1 cm/s, while a 4.241 log reduction in planktonic bacteria was achieved with 2.4 cm/min treatment. CONCLUSION These results represent a 500-fold increase in biofilm removal speeds and a 6.2-fold increase in bacterial killing speeds compared with previously published methods. These findings indicate that histotripsy shows promise for the treatment of catheter-associated biofilms and planktonic bacteria in a clinically relevant time frame.
Collapse
Affiliation(s)
- Ryan Morse
- Virginia Tech Carilion School of Medicine, Virginia Tech, Roanoke, VA, USA.
| | | | - Elizabeth Nowak
- Internal Medicine, Division of Infectious Disease, Carilion Medical Center, Roanoke, VA, USA
| | - Jayasimha Rao
- Virginia Tech Carilion School of Medicine, Virginia Tech, Roanoke, VA, USA; Internal Medicine, Division of Infectious Disease, Carilion Medical Center, Roanoke, VA, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Roanoke, VA, USA
| |
Collapse
|
5
|
Zhang Q, Yang Y, Xue H, Zhang H, Yuan Z, Shen Y, Guo X, Fan Z, Wu X, Zhang D, Tu J. Intensified and controllable vaporization of phase-changeable nanodroplets induced by simultaneous exposure of laser and ultrasound. ULTRASONICS SONOCHEMISTRY 2023; 94:106312. [PMID: 36731283 PMCID: PMC9926226 DOI: 10.1016/j.ultsonch.2023.106312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/20/2023] [Accepted: 01/22/2023] [Indexed: 06/18/2023]
Abstract
Phase-changeable contrast agents have been proposed as a next-generation ultrasound contrast agent over conventional microbubbles given its stability, longer circulation time and ability to extravasate. Safe vaporization of nanodroplets (NDs) plays an essential role in the practical translation of ND applications in industry and medical therapy. In particular, the exposure parameters for initializing phase change as well as the site of phase change are concerned to be controlled. Compared to the traditional optical vaporization or acoustic droplet vaporization, this study exhibited the potential of using simultaneous, single burst laser and ultrasound incidence as a means of activating phase change of NDs to generate cavitation nuclei with reduced fluence and sound pressure. A theoretical model considering the laser heating, vapor cavity nucleation and growth was established, where qualitative agreement with experiment findings were found in terms of the trend of combined exposure parameters in order to achieve the same level of vaporization outcome. The results indicate that using single burst laser pulse and 10-cycle ultrasound might be sufficient to lower the exposure levels under FDA limit for laser skin exposure and ultrasound imaging. The combination of laser and ultrasound also provides temporal and spatial control of ND vaporization and cavitation nucleation without altering the sound field, which is beneficial for further safe and effective applications of phase-changeable NDs in medical, environmental, food processing and other industrial areas.
Collapse
Affiliation(s)
- Qi Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Yanye Yang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Honghui Xue
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China; Wuxi Vocational Institute of Commerce, Wuxi 214153, Jiangsu, China
| | - Haijun Zhang
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai 200092, China; National United Engineering Laboratory for Biomedical Material Modification, Branden Industrial Park, Dezhou 251100, Shandong, China
| | - Ziyan Yuan
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Yuchen Shen
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Xiasheng Guo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Zheng Fan
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Xiaoge Wu
- Environment Science and Engineering College, Yangzhou University, Yangzhou 225009, Jiangsu, China.
| | - Dong Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| | - Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| |
Collapse
|