1
|
Phoon CK, Aristizábal O, Farhoud M, Turnbull DH, Wadghiri YZ. Mouse Cardiovascular Imaging. Curr Protoc 2024; 4:e1116. [PMID: 39222027 PMCID: PMC11371386 DOI: 10.1002/cpz1.1116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
The mouse is the mammalian model of choice for investigating cardiovascular biology, given our ability to manipulate it by genetic, pharmacologic, mechanical, and environmental means. Imaging is an important approach to phenotyping both function and structure of cardiac and vascular components. This review details commonly used imaging approaches, with a focus on echocardiography and magnetic resonance imaging, with brief overviews of other imaging modalities. In this update, we also emphasize the importance of rigor and reproducibility in imaging approaches, experimental design, and documentation. Finally, we briefly outline emerging imaging approaches but caution that reliability and validity data may be lacking. © 2024 Wiley Periodicals LLC.
Collapse
Affiliation(s)
- Colin K.L. Phoon
- Division of Pediatric Cardiology, Department of Pediatrics, New York University Grossman School of Medicine, New York, NY
| | - Orlando Aristizábal
- Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, & Center for Advanced Imaging Innovation and Research, New York University Grossman School of Medicine, New York, NY
- Preclinical Imaging, Division for Advanced Research Technologies, New York University Grossman School of Medicine, New York, NY
| | | | - Daniel H. Turnbull
- Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, & Center for Advanced Imaging Innovation and Research, New York University Grossman School of Medicine, New York, NY
- Department of Pathology, New York University Grossman School of Medicine, New York, New York
| | - Youssef Z. Wadghiri
- Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, & Center for Advanced Imaging Innovation and Research, New York University Grossman School of Medicine, New York, NY
- Preclinical Imaging, Division for Advanced Research Technologies, New York University Grossman School of Medicine, New York, NY
| |
Collapse
|
2
|
Tomsits P, Volz L, Xia R, Chivukula A, Schüttler D, Clauß S. Medetomidine/midazolam/fentanyl narcosis alters cardiac autonomic tone leading to conduction disorders and arrhythmias in mice. Lab Anim (NY) 2023; 52:85-92. [PMID: 36959339 PMCID: PMC10063441 DOI: 10.1038/s41684-023-01141-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 02/15/2023] [Indexed: 03/25/2023]
Abstract
Arrhythmias are critical contributors to cardiovascular morbidity and mortality. Therapies are mainly symptomatic and often insufficient, emphasizing the need for basic research to unveil the mechanisms underlying arrhythmias and to enable better and ideally causal therapies. In translational approaches, mice are commonly used to study arrhythmia mechanisms in vivo. Experimental electrophysiology studies in mice are performed under anesthesia with medetomidine/midazolam/fentanyl (MMF) and isoflurane/fentanyl (IF) as commonly used regimens. Despite evidence of adverse effects of individual components on cardiac function, few data are available regarding the specific effects of these regimens on cardiac electrophysiology in mice. Here we present a study investigating the effects of MMF and IF narcosis on cardiac electrophysiology in vivo in C57BL/6N wild-type mice. Telemetry transmitters were implanted in a group of mice, which served as controls for baseline parameters without narcosis. In two other groups of mice, electrocardiogram and invasive electrophysiology studies were performed under narcosis (with either MMF or IF). Basic electrocardiogram parameters, heart rate variability parameters, sinus node and atrioventricular node function, and susceptibility to arrhythmias were assessed. Experimental data suggest a remarkable influence of MMF on cardiac electrophysiology compared with IF and awake animals. While IF only moderately reduced heart rate, MMF led to significant bradycardia, spontaneous arrhythmias, heart rate variability alterations as well as sinus and AV node dysfunction, and increased inducibility of ventricular arrhythmias. On the basis of these observed effects, we suggest avoiding MMF in mice, specifically when studying cardiac electrophysiology, but also whenever a regular heartbeat is required for reliable results, such as in heart failure or imaging research.
Collapse
Affiliation(s)
- Philipp Tomsits
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich, Munich Heart Alliance (MHA), Munich, Germany.
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany.
| | - Lina Volz
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich, Munich Heart Alliance (MHA), Munich, Germany
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany
| | - Ruibing Xia
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany
| | - Aparna Chivukula
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich, Munich Heart Alliance (MHA), Munich, Germany
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany
| | - Dominik Schüttler
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich, Munich Heart Alliance (MHA), Munich, Germany
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany
| | - Sebastian Clauß
- Medizinische Klinik und Poliklinik I, University Hospital Munich, Campus Grosshadern and Innenstadt, Ludwig-Maximilians University Munich (LMU), Munich, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich, Munich Heart Alliance (MHA), Munich, Germany.
- Institute of Surgical Research at the Walter-Brendel-Centre of Experimental Medicine, University Hospital, LMU Munich, Munich, Germany.
- Interfaculty Center for Endocrine and Cardiovascular Disease Network Modelling and Clinical Transfer (ICONLMU), LMU Munich, Munich, Germany.
| |
Collapse
|
3
|
Thielen NT, Kleinsasser AA, Freeling JL. Myocardial contrast echocardiography assessment of mouse myocardial infarction: comparison of kinetic parameters with conventional methods. PeerJ 2021; 9:e11500. [PMID: 34141476 DOI: 10.7717/peerj.11500/supp-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/02/2021] [Indexed: 05/25/2023] Open
Abstract
This study explores the use of a minimally invasive assessment of myocardial infarction (MI) in mice using myocardial contrast echocardiography (MCE). The technique uses existing equipment and software readily available to the average researcher. C57/BL6 mice were randomized to either MI or sham surgery and evaluated using MCE at 1- or 2-weeks post-surgery. Size-isolated microbubbles were injected via retro-orbital catheter where their non-linear characteristics were utilized to produce the two-dimensional parameters of Wash-in-Rate and the Peak Enhancement, indicative of relative myocardial perfusion and blood volume, respectively. Three-dimensional cardiac reconstructions allowed the calculation of the Percent Agent, interpreted as the vascularity of the entire myocardium. These MCE parameters were compared to conventional assessments including M-Mode, strain analysis, and 2,3,5-Triphenyltetrazolium chloride (TTC) staining. Except for the Wash-in-Rate 2-week cohort, all MCE parameters were able to differentiate sham-operated versus MI animals and correlated with TTC staining (P < 0.05). MCE parameters were also able to identify MI group animals which failed to develop infarctions as determined by TTC staining. This study provides basic validation of these MCE parameters to detect MI in mice complementary to conventional methods while providing additional hemodynamic information in vivo.
Collapse
Affiliation(s)
- Nicholas T Thielen
- Sanford School of Medicine, University of South Dakota, Vermillion, South Dakota, United States
| | - Adison A Kleinsasser
- Research Computing Group, University of South Dakota, Vermillion, South Dakota, United States
| | - Jessica L Freeling
- Basic Biomedical Sciences, University of South Dakota, Vermillion, South Dakota, United States
| |
Collapse
|
4
|
Thielen NT, Kleinsasser AA, Freeling JL. Myocardial contrast echocardiography assessment of mouse myocardial infarction: comparison of kinetic parameters with conventional methods. PeerJ 2021; 9:e11500. [PMID: 34141476 PMCID: PMC8176928 DOI: 10.7717/peerj.11500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/02/2021] [Indexed: 01/14/2023] Open
Abstract
This study explores the use of a minimally invasive assessment of myocardial infarction (MI) in mice using myocardial contrast echocardiography (MCE). The technique uses existing equipment and software readily available to the average researcher. C57/BL6 mice were randomized to either MI or sham surgery and evaluated using MCE at 1- or 2-weeks post-surgery. Size-isolated microbubbles were injected via retro-orbital catheter where their non-linear characteristics were utilized to produce the two-dimensional parameters of Wash-in-Rate and the Peak Enhancement, indicative of relative myocardial perfusion and blood volume, respectively. Three-dimensional cardiac reconstructions allowed the calculation of the Percent Agent, interpreted as the vascularity of the entire myocardium. These MCE parameters were compared to conventional assessments including M-Mode, strain analysis, and 2,3,5-Triphenyltetrazolium chloride (TTC) staining. Except for the Wash-in-Rate 2-week cohort, all MCE parameters were able to differentiate sham-operated versus MI animals and correlated with TTC staining (P < 0.05). MCE parameters were also able to identify MI group animals which failed to develop infarctions as determined by TTC staining. This study provides basic validation of these MCE parameters to detect MI in mice complementary to conventional methods while providing additional hemodynamic information in vivo.
Collapse
Affiliation(s)
- Nicholas T Thielen
- Sanford School of Medicine, University of South Dakota, Vermillion, South Dakota, United States
| | - Adison A Kleinsasser
- Research Computing Group, University of South Dakota, Vermillion, South Dakota, United States
| | - Jessica L Freeling
- Basic Biomedical Sciences, University of South Dakota, Vermillion, South Dakota, United States
| |
Collapse
|
5
|
Cho JS, Lee J, Park KC, Yang KJ, Cho EJ. The relationship between miRNA-26b and connective tissue growth factor in rat models of aortic banding and debanding. Korean J Intern Med 2021; 36:596-607. [PMID: 31875666 PMCID: PMC8137408 DOI: 10.3904/kjim.2019.120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 07/23/2019] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND/AIMS Connective tissue growth factor (CTGF) is a profibrotic factor implicated in pressure overload-mediated myocardial fibrosis. In this study, we determined the role of predicted CTGF-targeting microRNAs (miRNAs) in rat models of aortic stenosis and reverse cardiac remodeling. METHODS Minimally invasive ascending aortic banding was performed in 24 7-week-old male Sprague-Dawley rats, which were divided into three groups. The banding group consisted of eight rats that were sacrificed immediately after 6 weeks of aortic constriction. The debanding group underwent aortic constriction for 4 weeks and was sacrificed 2 weeks after band removal. The third group underwent sham surgery. We investigated the expression of CTGF, transforming growth factor-β1 (TGFβ1), and matrix metalloproteinase-2 using ELISA and examined miRNA-26b, miRNA-133a, and miRNA-19b as predicted CTGF-targeting miRNAs based on miRNA databases in 24-hour TGFβ-stimulated and TGFβ- washed fibroblasts and myocardial tissues from all subjects. RESULTS CTGF was elevated in 24-hour TGFβ-stimulated fibroblasts and decreased in 24-hour TGFβ-washed fibroblasts. miRNA-26b was significantly increased in TGFβ-washed fibroblasts compared with control and TGFβ-stimulated fibroblasts (p < 0.05). CTGF expression was significantly higher in the banding group than that in the sham and debanding groups. The relative expression levels of miRNA-26b were higher in the debanding group than in the banding group. CONCLUSION The results of our study using models of aortic banding and debanding suggested that miRNA-26b was significantly increased after aortic debanding. The in vitro model yielded the same results: miRNA-26b was upregulated after removal of TGFβ from fibroblasts.
Collapse
Affiliation(s)
- Jung Sun Cho
- Division of Cardiology, Department of Internal Medicine, Daejeon St. Mary’s Hospital, The Catholic University of Korea, Daejeon, Korea
| | - Jongho Lee
- Department of Thoracic and Cardiovascular Surgery, Daejeon St. Mary’s Hospital, The Catholic University of Korea, Daejeon, Korea
| | - Ki Cheol Park
- Clinical Research Institute, College of Medicine, Daejeon St. Mary’s Hospital, The Catholic University of Korea, Daejeon, Korea
| | - Keum-Jin Yang
- Clinical Research Institute, College of Medicine, Daejeon St. Mary’s Hospital, The Catholic University of Korea, Daejeon, Korea
| | - Eun Joo Cho
- Division of Cardiology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea
- Correspondence to Eun Joo Cho, M.D. Division of Cardiology, Department of Internal Medicine, College of Medicine, Yeouido St. Mary’s Hospital, The Catholic University of Korea, 10 63-ro, Yeongdeungpo-gu, Seoul 07345, Korea Tel: +82-2-3779-1335 Fax: +82-2-780-9114 E-mail:
| |
Collapse
|