Berger D, Van Dyk S, Beaulieu L, Major T, Kron T. Modern Tools for Modern Brachytherapy. Clin Oncol (R Coll Radiol) 2023:S0936-6555(23)00182-6. [PMID: 37217434 DOI: 10.1016/j.clon.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 03/28/2023] [Accepted: 05/04/2023] [Indexed: 05/24/2023]
Abstract
This review aims to showcase the brachytherapy tools and technologies that have emerged during the last 10 years. Soft-tissue contrast using magnetic resonance and ultrasound imaging has seen enormous growth in use to plan all forms of brachytherapy. The era of image-guided brachytherapy has encouraged the development of advanced applicators and given rise to the growth of individualised 3D printing to achieve reproducible and predictable implants. These advances increase the quality of implants to better direct radiation to target volumes while sparing normal tissue. Applicator reconstruction has moved beyond manual digitising, to drag and drop of three-dimensional applicator models with embedded pre-defined source pathways, ready for auto-recognition and automation. The simplified TG-43 dose calculation formalism directly linked to reference air kerma rate of high-energy sources in the medium water remains clinically robust. Model-based dose calculation algorithms accounting for tissue heterogeneity and applicator material will advance the field of brachytherapy dosimetry to become more clinically accurate. Improved dose-optimising toolkits contribute to the real-time and adaptive planning portfolio that harmonises and expedites the entire image-guided brachytherapy process. Traditional planning strategies remain relevant to validate emerging technologies and should continue to be incorporated in practice, particularly for cervical cancer. Overall, technological developments need commissioning and validation to make the best use of the advanced features by understanding their strengths and limitations. Brachytherapy has become high-tech and modern by respecting tradition and remaining accessible to all.
Collapse
Affiliation(s)
- D Berger
- International Atomic Energy Agency, Vienna International Centre, Vienna, Austria.
| | - S Van Dyk
- Radiation Therapy Services, Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - L Beaulieu
- Service de Physique Médicale et Radioprotection, et Axe Oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, Québec, Canada; Département de Physique, de Génie Physique et d'Optique et Centre de Recherche sur le Cancer, Université Laval, Québec, Canada
| | - T Major
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary; Department of Oncology, Semmelweis University, Budapest, Hungary
| | - T Kron
- Peter MacCallum Cancer Centre and Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| |
Collapse
|
2
|
Mondal K, Mourya A, Choudhary S, Mandal A, Singh A, Aggarwal LM. Plan quality score to evaluate the dwell time deviation restricted inverse planning by simulated annealing and graphically optimized treatment plans for template based interstitial brachytherapy. Cancer Radiother 2023; 27:196-205. [PMID: 37088572 DOI: 10.1016/j.canrad.2022.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 09/15/2022] [Accepted: 10/18/2022] [Indexed: 04/25/2023]
Abstract
PURPOSE To evaluate the impact of dwell time deviation constraint (DTDC) on the quality of IPSA-optimized treatment plans in comparison with graphical plans using plan quality scores (PQS). MATERIAL AND METHODS Seventy optimized plans (graphical & IPSA with different DTDC values) of ten cervical cancer patients were generated. Various DVH parameters like D90, V100, V150, V200, V300 were compared to evaluate the impact of DTDC on target coverage and high dose regions inside target for different plans. Similarly, for the OAR dose, values of D2cc were compared. Various planning parameters like CI, COIN, DHI, DNR, ODI, EI and gain factor (GF) for different OARs were calculated. Based on these indices a plan quality score (PQS) was formulated and calculated. PQS values were used to see the impact of DTDC on plan quality of IPSA in comparison with dosimetric quality of graphical plan. RESULTS We have found that target coverage is similar for IPSA and graphically optimized treatment plans. However, dose homogeneity was improved in IPSA compared to graphical optimization whereas conformality was better in graphically optimized plans. OAR dose was less in IPSA plans. High-dose regions inside the target were also reduced in IPSA comparatively. However, IPSA plans optimized with various values of DTDC did not necessarily reduce high-dose regions beyond 0.6. Plan quality scores (PQS) were 6.31, 6.31, 6.34, and 6.17 for the graphically optimized plan, IPSA with DTDC values of 0.0, 0.4, and 1.0 respectively. CONCLUSION We found that IPSA is dosimetrically advantageous over graphical optimization. IPSA with a DTDC value of 0.4 improved overall plan quality. However, DTDC value beyond 0.6 produces dosimetrically sub-optimal plans hence the use of DTDC should be very selective and limited.
Collapse
Affiliation(s)
- K Mondal
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India
| | - A Mourya
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India
| | - S Choudhary
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India
| | - A Mandal
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India
| | - A Singh
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India
| | - L M Aggarwal
- Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, 221005 Varanasi, Uttar Pradesh, India.
| |
Collapse
|
3
|
Interstitial brachytherapy for gynecologic malignancies: Complications, toxicities, and management. Brachytherapy 2021; 20:995-1004. [PMID: 33789823 DOI: 10.1016/j.brachy.2020.12.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 12/15/2020] [Accepted: 12/17/2020] [Indexed: 11/21/2022]
Abstract
From both a disease and management perspective, locally advanced gynecologic cancers present a significant challenge. Dose escalation with brachytherapy serves as a key treatment, providing conformal radiation while sparing at-risk organs. Intracavitary brachytherapy techniques have been shown to be effective, with improving tumor control and toxicity profiles with the advent of three-dimensional image planning. Despite this, the variations in tumor size, location, and pelvic anatomy may lead to suboptimal dosimetry with standard intracavitary applicators in some clinical scenarios. The addition of interstitial needles (interstitial brachytherapy (ISBT)) can improve the conformality of brachytherapy treatments by adding needles to peripheral (and central) regions of the target volume, improving the ability to escalate doses in these undercovered regions while sparing organs at risk. Interstitial brachytherapy can be delivered by intracavitary and interstitial hybrid applicators (ICBT/ISBT), perineal template (P-ISBT), or by free-hand technique. ISBT has however yet to be widely available because of concerns of complications and toxicities from this specialized treatment. However, with the increasing use of three-dimensional image-guided brachytherapy, there is an opportunity to increase the level of expertise in the gynecologic radiation oncology community with an improved understanding of the potential complications and morbidity. In this article, we review the acute and long-term toxicity in both ICBT/ISBT and P-ISBT using image-guided brachytherapy.
Collapse
|
4
|
Fu Q, Xu Y, Zuo J, An J, Huang M, Yang X, Chen J, Yan H, Dai J. Comparison of two inverse planning algorithms for cervical cancer brachytherapy. J Appl Clin Med Phys 2021; 22:157-165. [PMID: 33626225 PMCID: PMC7984476 DOI: 10.1002/acm2.13195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 01/14/2021] [Accepted: 01/18/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To compare two inverse planning algorithms, the hybrid inverse planning optimization (HIPO) algorithm and the inverse planning simulated annealing (IPSA) algorithm, for cervical cancer brachytherapy and provide suggestions for their usage. MATERIAL AND METHODS This study consisted of 24 cervical cancer patients treated with CT image-based high-dose-rate brachytherapy using various combinations of tandem/ovoid applicator and interstitial needles. For fixed catheter configurations, plans were retrospectively optimized with two methods: IPSA and HIPO. The dosimetric parameters with respect to target coverage, localization of high dose volume (LHDV), conformal index (COIN), and sparing of organs at risk (OARs) were evaluated. A plan assessment method which combines a graphical analysis and a scoring index was used to compare the quality of two plans for each case. The characteristics of dwell time distributions of the two plans were also analyzed in detail. RESULTS Both IPSA and HIPO can produce clinically acceptable treatment plans. The rectum D2cc was slightly lower for HIPO as compared to IPSA (P = 0.002). All other dosimetric parameters for targets and OARs were not significantly different between the two algorithms. The generated radar plots and scores intuitively presented the plan properties and enabled to reflect the clinical priorities for the treatment plans. Significant different characteristics were observed between the dwell time distributions generated by IPSA and HIPO. CONCLUSIONS Both algorithms could generate high-quality treatment plans, but their performances were slightly different in terms of each specific patient. The clinical decision on the optimal plan for each patient can be made quickly and consistently with the help of the plan assessment method. Besides, the characteristics of dwell time distribution were suggested to be taken into account during plan selection. Compared to IPSA, the dwell time distributions generated by HIPO may be closer to clinical preference.
Collapse
Affiliation(s)
- Qi Fu
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Yingjie Xu
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Jing Zuo
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Jusheng An
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Manni Huang
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Xi Yang
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Jiayun Chen
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Hui Yan
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medial Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
5
|
Feasibility of interstitial stepping-source electronic brachytherapy to locally inoperable tumors. J Contemp Brachytherapy 2020; 12:480-486. [PMID: 33299437 PMCID: PMC7701928 DOI: 10.5114/jcb.2020.100381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 07/16/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose Radiotherapy is the mainstay in the treatment of locally inoperable tumors. Interstitial electronic needle-based kilovoltage brachytherapy (EBT) could be an economic alternative to high-dose-rate (HDR) brachytherapy or permanent seed implantation (PSI). In this work, we evaluated if locally inoperable tumors treated with PSI at our institution may be suitable for EBT. Material and methods A total of 10 post-interventional computed tomography (CT) scans of patients, who received PSI and simulated stepping-source EBT applied with Intrabeam system and needle applicator were used. EBT treatment planning software with 3-dimensional image and projection of applicator were applied for designing trajectories and establishing dwell positions. Dwell position doses were summarized, and doses covering 90% of the target volume (D90) achieved with stepping-source EBT were compared to those of PSI. Additionally, conformality of dose distributions and total irradiation time were assessed using conformation number (CN) or conformal index (COIN). Results In all patients, D90 of EBT exceeded the prescribed dose or D90 of PSI on average by 4.7% or 21.3% relative to the prescribed dose, respectively. Mean number of trajectories was 5.0 for EBT and 6.9 for PSI. Average CN/COIN for EBT was 0.69, with a mean irradiation time of 27.8 minutes for standardized dose of 13 Gy. Conclusions Stepping-source EBT allowed for a conformal treatment of inoperable interstitial tumors with similar D90. Fewer trajectories were required for EBT in majority of cases.
Collapse
|
6
|
Palled SR, Radhakrishna NK, Manikantan S, Khanum H, Venugopal BK, Vishwanath L. Dosimetric comparison of manual forward planning with uniform dwell times versus volume-based inverse planning in interstitial brachytherapy of cervical malignancies. Rep Pract Oncol Radiother 2020; 25:851-855. [PMID: 32982589 DOI: 10.1016/j.rpor.2020.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 05/31/2020] [Accepted: 08/12/2020] [Indexed: 11/26/2022] Open
Abstract
Aim Dosimetic comparison of manual forward planning(MFP) with inverse planning(IP) for interstitial brachytherapy(ISBT) in cervical carcinoma. Background Brachytherapy planning by MFP is more reliable but time-consuming method, whereas IP has been explored more often for its ease and rapidness. The superiority of either is yet to be established. Methodology Two plans were created on data sets of 24 patients of cervical carcinoma who had undergone ISBT, one by MFP with uniform dwell times and another IP on BrachyVision 13.7 planning system with a dose prescription of 600 cGy. Isodose shaper was used for improving conformity & homogeneity. Dosimetric parameters for target and organs at risk (OARs) were recorded. Conformity index (COIN), dose homogeneity index (DHI), overdose index (OI), Coverage index (CI) and dose nonuniformity ratio (DNR) were calculated. Results Mean high risk clinical target volume: 73.05(±20.7)cc, D90: 5.51 Gy vs. 5.6 Gy (p = 0.017), V100: 81.77 % vs. 83.74 % (p = 0.002), V150: 21.7 % vs. 24.93 % (p = 0.002), V200: 6.3 % vs. 6.4 % (p=0.75) for IP and MFP, respectively. CI: 0.81(IP) and 0.83(MFP) (p = 0.003); however, COIN was 0.79 for both plans. D2cc of OARs was statistically better with IP (bladder 54.7 % vs. 56.1 %, p = 0.03; rectum 63 % vs. 64.7 %, (p = 0.0008). Conclusion Both MFP and IP are equally acceptable dosimetrically. With higher dose achieved to the target, for a similar OAR dose, MFP provides greater user flexibility of dwell positions within the target as well as better optimization. Isodose shaper may be carefully used for fine tuning. Larger sample sizes and clinical correlation will better answer the superiority of one over the other.
Collapse
Affiliation(s)
- Siddanna R Palled
- Radiation Oncology, Kidwai Memorial Institute of Oncology, Bengaluru, India
| | | | - Senthil Manikantan
- Medical Physicist, Kidwai Memorial Institute of Oncology, Bengaluru, India
| | - Hashmath Khanum
- Radiation Oncology, Kidwai Memorial Institute of Oncology, Bengaluru, India
| | - Bindu K Venugopal
- Radiation Oncology, Kidwai Memorial Institute of Oncology, Bengaluru, India
| | - Lokesh Vishwanath
- Radiation Oncology, Kidwai Memorial Institute of Oncology, Bengaluru, India
| |
Collapse
|
7
|
Does inverse planning improve plan quality in interstitial high-dose-rate breast brachytherapy? J Contemp Brachytherapy 2020; 12:166-174. [PMID: 32395141 PMCID: PMC7207228 DOI: 10.5114/jcb.2020.94584] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 03/12/2020] [Indexed: 11/22/2022] Open
Abstract
Purpose To investigate the effect of input parameters for an inverse optimization algorithm, and dosimetrically evaluate and compare clinical treatment plans made by inverse and forward planning in high-dose-rate interstitial breast implants. Material and methods By using a representative breast implant, input parameters responsible for target coverage and dose homogeneity were changed step-by-step, and their optimal values were determined. Then, effects of parameters on dosimetry of normal tissue and organs at risk were investigated. The role of dwell time modulation restriction was also studied. With optimal input parameters, treatment plans of forty-two patients were re-calculated using an inverse optimization algorithm (HIPO). Then, a pair-wise comparison between forward and inverse plans was performed using dose-volume parameters. Results To find a compromise between target coverage and dose homogeneity, we recommend using weight factors in the range of 70-90 for minimum dose, and in the range of 10-30 for maximum dose. Maximum dose value of 120% with a weight factor of 5 is recommended for normal tissue. Dose constraints for organs at risk did not play an important role, and the dwell time gradient restriction had only minor effect on target dosimetry. In clinical treatment plans, at identical target coverage, the inverse planning significantly increased the dose conformality (COIN, 0.75 vs. 0.69, p < 0.0001) and improved the homogeneity (DNR, 0.35 vs. 0.39, p = 0.0027), as compared to forward planning. All dosimetric parameters for non-target breast, ipsilateral lung, ribs, and heart were significantly better with inverse planning. The most exposed small volumes for skin were less in HIPO plans, but without statistical significance. Volume irradiated by 5% was 173.5 cm3 in forward and 167.7 cm3 in inverse plans (p = 0.0247). Conclusions By using appropriate input parameters, inverse planning can provide dosimetrically superior dose distributions over forward planning in interstitial breast implants.
Collapse
|
8
|
Verification of needle guidance accuracy in pelvic phantom using registered ultrasound and MRI images for intracavitary/interstitial gynecologic brachytherapy. J Contemp Brachytherapy 2020; 12:147-159. [PMID: 32395139 PMCID: PMC7207233 DOI: 10.5114/jcb.2020.94583] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 03/17/2020] [Indexed: 12/24/2022] Open
Abstract
Purpose In combined intracavitary/interstitial (IC/IS) gynecologic brachytherapy, trackers attached to interstitial needles of localize real-time needle trajectories, and intraoperative ultrasound (US) images provide updated anatomy information during needle insertions. To achieve an effective visualization and image guidance, real-time needle trajectories and US images can be unified in preoperative magnetic resonance imaging (MRI) image space together. This study evaluates the rigid registration accuracy between US images and MRI images as well as the registration accuracy between US images and real-time needle trajectories in a pelvic phantom. Material and methods A method for US probe calibration and accomplished rigid registration between MRI images and US images was proposed. An IC/IS applicator was designed. Micro electromagnetic sensor to track and localize real-time needle trajectories in 3D MRI image space was used. Marker validation to test the accuracy of US probe calibration and pelvic phantom validation to test the registration accuracy between US images and MRI images was conducted as well as and pelvic phantom study to verify the registration accuracy between real-time needle trajectories and needle trajectories in registered US images. Results US probe calibration accuracy was 0.80 ±0.23 mm (n = 60). Registration accuracy between US images and MRI images were 1.01 ±0.22 mm in the axial plane (n = 60) and 1.14 ±0.20 mm in the sagittal plane (n = 24). Registration accuracy between real-time needle trajectories and needle trajectories in registered US images were 1.25 ±0.31 mm (n = 40) and 1.61 ±0.28 degrees (n = 5), respectively. Conclusions In this study, we showed that under ideal conditions, rigid registration between MRI images and US images obtained high accuracy for real-time image guidance. Additionally, registered US images provided accurate image guidance during visual needle insertion in IC/IS gynecologic brachytherapy to achieve a combination of effective visualization and image guidance.
Collapse
|
9
|
Dose distribution of brachytherapy for locally advanced (stage IIB) cervical cancer. Brachytherapy 2019; 19:66-72. [PMID: 31837988 DOI: 10.1016/j.brachy.2019.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 10/10/2019] [Accepted: 10/12/2019] [Indexed: 11/21/2022]
Abstract
PURPOSE The aim of the study was to compare the dose distributions of combined intracavitary and interstitial (IC/IS) brachytherapy with 3-catheter IC brachytherapy in treating locally advanced (stage IIB) cervical cancer. METHODS AND MATERIALS In total, 46 patients were included, each with stage IIB cervical cancer, local lesion sizes ≥5 cm, and tumors that had not regressed after 45 Gy/25 F external intensity-modulated radiotherapy. To identify the dosimetric advantage of delivering a local boost to high-risk (HR)-cervix in IC/IS, patients were divided into two groups: IC/IS and IC/IS + HR-cervix. The differences in dosimetric parameters were compared between the two groups. Comparisons were then made between the parameters of the four planning methods: IC (Point A), IC (three dimensional [3D]), IC/IS, and IC/IS + HR-cervix. RESULTS In patients with IC/IS implants, the relative uterine tandem dwell time was significantly extended in the IC/IS + HR-cervix group, and the V150 and V200 volumes of HR-cervix were increased (all p < 0.001), whereas the D90 and D100 values of the IC/IS + HR-cervix group were lower than those in the IC/IS group. In pairwise comparisons, HR-cervix V150 and V200 values were lowest in the IC/IS group, followed by the IC (3D), IC/IS + HR-cervix, and IC (Point A) groups. All differences were statistically significant (p < 0.05), with the exception of IC/IS vs. IC (3D). CONCLUSIONS When treating locally advanced cervical cancer (stage IIB, local residual volume ≥5 cm after external radiotherapy), the IC/IS + HR-cervix optimization method can meet the HR clinical target volume D90 dose requirement, normal tissue dose limits, and can escalate doses to local areas of the cervix.
Collapse
|
10
|
Dosimetric comparison of inverse optimisation methods versus forward optimisation in HDR brachytherapy of breast, cervical and prostate cancer. Strahlenther Onkol 2019; 195:991-1000. [PMID: 31482321 PMCID: PMC6811387 DOI: 10.1007/s00066-019-01513-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Accepted: 08/08/2019] [Indexed: 11/29/2022]
Abstract
Objective Dosimetric comparison of HIPO (hybrid inverse planning optimisation) and IPSA (inverse planning simulated annealing) inverse and forward optimisation (FO) methods in brachytherapy (BT) of breast, cervical and prostate cancer. Methods At our institute 38 breast, 47 cervical and 50 prostate cancer patients treated with image-guided interstitial high-dose-rate BT were selected. Treatment plans were created using HIPO and IPSA inverse optimisation methods as well as FO. The dose–volume parameters of different treatment plans were compared with Friedman ANOVA and the LSD post-hoc test. Results IPSA creates less dose coverage to the target volume than HIPO or FO: V100 was 91.7%, 91% and 91.9% for HIPO, IPSA and FO plans (p = 0.1784) in breast BT; 90.4%, 89.2% and 91% (p = 0.0045) in cervical BT; and 97.1%, 96.2% and 97.7% (p = 0.0005) in prostate BT, respectively. HIPO results in more conformal plans: COIN was 0.72, 0.71 and 0.69 (p = 0.0306) in breast BT; 0.6, 0.47 and 0.58 (p < 0.001) in cervical BT; and 0.8, 0.7 and 0.7 (p < 0.001) in prostate BT, respectively. In breast BT, dose to the skin and lung was smaller with HIPO and FO than with IPSA. In cervical BT, dose to the rectum, sigmoid and bowel was larger using IPSA than with HIPO or FO. In prostate BT, dose to the urethra was higher and the rectal dose was smaller using FO than with inverse methods. Conclusion In interstitial breast and prostate BT, HIPO results in comparable dose–volume parameters to FO, but HIPO plans are more conformal. In cervical BT, HIPO produces dosimetrically acceptable plans only when more needles are used. The dosimetric quality of IPSA plans is suboptimal and results in unnecessary larger active lengths.
Collapse
|
11
|
Dosimetric comparison of graphical optimization and inverse planning simulated annealing for brachytherapy of cervical cancer. J Contemp Brachytherapy 2019; 11:379-383. [PMID: 31523240 PMCID: PMC6737576 DOI: 10.5114/jcb.2019.87145] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 06/25/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose Graphical optimization (GO) and inverse planning simulated annealing (IPSA) are the main treatment planning optimization techniques used in patients undergoing 3D brachytherapy treatment. This study aims to compare the dosimetric difference of plans optimized by GO and IPSA in cervical cancer brachytherapy. Material and methods 21 cervical cancer patients data sets consisted of computed tomography (CT) and magnetic resonance imaging (MRI), acquired with the Fletcher applicator in situ were transferred to the Oncentra brachytherapy planning system. For each patient, the treatment plan was initially optimized with GO to reach a maximal D90 tumor dose (6 Gy/fraction, 5 fractions), while keeping the dose to organs at risk (OARs) as low as possible. A second plan was then optimized with IPSA on the same CT images and data set (i.e., contours, catheters, and location of dwell points). Targets and OARs dose volume histograms and irradiation time were compared; data were analyzed with paired t-test; p value < 0.05 was considered statistically significant. Results The plans with both optimizations meet the clinical requirements. The mean D90 of the clinical target volume was comparable for GO and IPSA. Similar values (p > 0.05) of target V100, V150, V200, HI, and CI were registered for GO and IPSA optimizations. Bladder and rectum D1cc and D2cc obtained by GO resulted in larger values than those obtained by IPSA (p = 0.002). V75 for bladder and rectum were slightly higher for IPSA, but without statistical difference (p > 0.05). The irradiation time was comparable (p > 0.05). Conclusions In 3D brachytherapy of cervical cancer, GO and IPSA optimizations do not present a significant difference in target dose coverage; nevertheless, IPSA may reduce the maximum dose to normal tissue when compared with GO.
Collapse
|
12
|
Influence of dwell time homogeneity error weight parameter on treatment plan quality in inverse optimized high-dose-rate cervix brachytherapy using SagiPlan. J Contemp Brachytherapy 2019; 11:256-266. [PMID: 31435433 PMCID: PMC6701378 DOI: 10.5114/jcb.2019.85903] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 05/04/2019] [Indexed: 01/30/2023] Open
Abstract
Purpose Restricting the gradients of dwell times between adjacent dwell positions can potentially be beneficial in reducing the probability of unwanted hot/cold spots occurring, if the planned applicators/anatomy relative positions change before or during treatment. This constraint, however, may degrade plan quality. This study, for the first time, aims to quantify the impact of modulation restriction on plan quality indices in inverse optimization for cervix high-dose-rate (HDR) brachytherapy using the BEBIG SagiPlan treatment planning system. Material and methods Ten cervical cancer patient plans were optimized for treatment with a BEBIG SagiNova 60Co HDR afterloader using the min/max inverse planning method, with dwell time homogeneity error weight (DTHEW) parameter values of 0 to 10. Dwell time homogeneity and gradients as well as various plan quality indices were analyzed. Results For DTHEW = 0, min/max-based optimization yielded higher HR-CTV D90 values than the variance-based option (p < 0.001) and was therefore selected for this study. Averaging over all patients, selecting non-zero DTHEWs resulted in a general increase in dwell time homogeneity and decrease in mean and maximum adjacent dwell time gradients, especially between DTHEWs of 0 and 1. For DTHEW > 1, an increase of this parameter did not always result in more homogeneous dwell times or reduced gradients in individual patients. There was a negative correlation between DTHEW and both HR-CTV D90 and V100 (p < 0.001, r = –0.91). Increasing DTHEW also negatively affected conformity index (p < 0.001, r = –0.99). Changes in rectum and sigmoid colon D2cc were insignificant. There was a strong positive relationship between bladder D2cc and DTHEW (p < 0.001, r = 0.99). Conclusions Assuming a static geometry, statistically significant degradation of plan quality can result from restricting the dwell time homogeneity in min/max-based optimization of cervix HDR brachytherapy plans using SagiPlan. Therefore, setting DTHEW to zero is indicated for the type of patient plans considered in this study.
Collapse
|
13
|
Wali L, Helal A, Darwesh R, Attar M. A dosimetric comparison of Volumetric Modulated Arc Therapy (VMAT) and High Dose Rate (HDR) brachytherapy in localized cervical cancer radiotherapy. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:473-483. [PMID: 30958322 DOI: 10.3233/xst-180468] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
BACKGROUND Cervical cancer radiotherapy is usually administrated through 3-Dimensional Conformal Radiation Therapy (3DCRT) followed by a brachytherapy (BT) boost. PURPOSE To investigate whether Volumetric Modulated Arc Therapy (VMAT) can replace High Dose Rate (HDR) intracavitary BT boost for patients undergoing cervical cancer radiotherapy. MATERIALS AND METHODS Computed Tomography (CT) images for ten patients with tandem and ovoids were included in this study. Target volumes, rectum, bladder, sigmoid, small bowel and both femoral heads were delineated. Two plans were carried out including (a) a BT plan optimized manually by modifying dwell time and Ir-192 source positions, (b) a VMAT plan generated using two partial arcs with 10 MV photon beam. The prescribed dose was 7 Gy. The relevant dose volume parameters (DVPs) of target volumes and OARs for the two plans were analyzed statistically using SPSS Wilcoxon Signed Rank test. RESULTS VMAT plan showed a significant reduction of 9.1%, 9.3%, 15.4%, 14.4% and 13.1% in rectum maximum dose, rectum D2cc, bladder maximum dose, bladder D2cc and sigmoid maximum dose (P < 0.05). VMAT and BT plans showed comparable D2cc of sigmoid and small bowel maximum doses (P = 0.333 and P = 0.646). On the other hand, VMAT showed significantly higher small bowel D2cc and maximum point dose for both femoral heads comparing to BT plan (P < 0.05). Also, VMAT plan yielded greater homogeneous target coverage compared to BT plan (P < 0.05). CONCLUSION The study demonstrated that VMAT plan achieves significant dose reduction of rectum, bladder and sigmoid, as well as superior homogeneous target coverage compared to BT plan. On the other hand, VMAT delivers more radiation exposures to small bowel and femoral heads.
Collapse
Affiliation(s)
- Lila Wali
- Physics Department, Faculty of Science, King Abdul-Aziz University, Jeddah, Saudi Arabia
| | - Azza Helal
- Physics Department, Faculty of Science, King Abdul-Aziz University, Jeddah, Saudi Arabia
- Medical Physics Unit, Radiology and Intervention Dept, Faculty of Medicine, Alexandria University, Egypt
| | - Reem Darwesh
- Physics Department, Faculty of Science, King Abdul-Aziz University, Jeddah, Saudi Arabia
| | - Mohammed Attar
- Radiation Therapy Unit, King Abdul-Aziz University Hospital, Jeddah, Saudi Arabia
| |
Collapse
|
14
|
Choi CH, Park SY, Park JM, Wu HG, Kim JH, Kim JI. Comparison of the IPSA and HIPO algorithms for interstitial tongue high-dose-rate brachytherapy. PLoS One 2018; 13:e0205229. [PMID: 30286187 PMCID: PMC6171910 DOI: 10.1371/journal.pone.0205229] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Accepted: 09/21/2018] [Indexed: 11/30/2022] Open
Abstract
Purpose This study aimed to compare the inverse planning simulated annealing (IPSA) stochastic algorithm with the hybrid inverse planning and optimization (HIPO) algorithm for interstitial tongue high-dose-rate (HDR) brachytherapy. Methods Twenty patients who received radiotherapy for tongue cancer using interstitial HDR brachytherapy were retrospectively selected for this study. Oncentra Brachy v. 4.3 was used for IPSA and HIPO planning. Four to eight fixed catheter configurations were determined according to the target shape. During the optimization process, predetermined constrain values were used for each IPSA and HIPO plan. The dosimetric parameters and dwell time were analyzed to evaluate the performances of the plans. Results The total dwell time using IPSA was 4 seconds longer than that of HIPO. The number of active positions per catheter for the IPSA plans were approximately 2.5 fewer than those of the HIPO plans. The dose-volumetric parameters related to the clinical target volume with IPSA were lower than those with HIPO. In terms of the dose-volumetric parameters related to normal tissue, HIPO tended to associate with slightly higher values than IPSA, without statistical significance. After GrO, the target coverages were satisfied to clinical goal for all patients. The total dwell times was approximately increased by 10%. Conclusions The IPSA and HIPO dose optimization algorithms generate similar dosimetric results. In terms of the dwell time, HIPO appears to be more beneficial.
Collapse
Affiliation(s)
- Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - So-Yeon Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Hong-Gyun Wu
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jin-Ho Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- * E-mail: (JHK); (JIK)
| | - Jung-in Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- * E-mail: (JHK); (JIK)
| |
Collapse
|
15
|
Kannan RA, Gururajachar JM, Ponni A, Koushik K, Kumar M, Alva RC, Harjani R, Murthy A. Comparison of manual and inverse optimisation techniques in high dose rate intracavitary brachytherapy of cervical cancer: A dosimetric study. Rep Pract Oncol Radiother 2015; 20:365-9. [PMID: 26549994 DOI: 10.1016/j.rpor.2015.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Revised: 03/02/2015] [Accepted: 05/24/2015] [Indexed: 11/17/2022] Open
Abstract
AIMS AND OBJECTIVES To compare dosimetrically the manual optimisation with IPSA using dose volume histograms (DVH) among patients treated for carcinoma of cervix with intracavitary brachytherapy. BACKGROUND With the advent of advanced imaging modalities, there has been a shift from conventional X-ray based planning to three-dimensional planning. Manual optimisation is widely used across various institutions but it is time consuming and operator dependant. Inverse planning simulated annealing (IPSA) is now available in various brachytherapy planning systems. But there is a paucity of studies comparing manual optimisation and IPSA in treatment of carcinoma cervix with intracavitary brachytherapy and hence this study. MATERIALS AND METHODS Fifteen consecutive patients treated between December 2013 and March 2014 with intracavitary brachytherapy for carcinoma of cervix were selected for this study. All patients were initially treated with external beam radiotherapy followed by intracavitary brachytherapy. The DVH was evaluated and compared between manually optimised plans and IPSA in the same set of patients. RESULTS There was a significant improvement in the HRCTV coverage, mean V100 of 87.75% and 82.37% (p = 0.001) and conformity index 0.67 and 0.6 (p = 0.007) for plans generated using IPSA and manual optimisation, respectively. Homogeneity index and dose to the OARs remained similar between the two groups. CONCLUSION The use of inverse planning in intracavitary brachytherapy of cervix has shown a significant improvement in the target volume coverage when compared with manual planning.
Collapse
Affiliation(s)
- Ram Abhinav Kannan
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | | | - Arul Ponni
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | - Kirthi Koushik
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | - Mohan Kumar
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | - Ram Charith Alva
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | - Ritika Harjani
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| | - Arvind Murthy
- Department of Radiation Oncology, M.S. Ramaiah Medical College, Bangalore 54, India
| |
Collapse
|
16
|
De Boeck L, Beliën J, Egyed W. Dose optimization in high-dose-rate brachytherapy: A literature review of quantitative models from 1990 to 2010. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.orhc.2013.12.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Siebert FA, Wolf S, Bertermann H, Nürnberg N, Bockelmann G, Kimmig B. Introduction of inverse dose optimization for ultrasound-based high-dose-rate boost brachytherapy: how we do it in Kiel. Brachytherapy 2014; 13:250-6. [PMID: 24613132 DOI: 10.1016/j.brachy.2014.01.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Revised: 01/25/2014] [Accepted: 01/30/2014] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To describe the introduction of inverse planning optimization for a two clinical target volume (CTV) concept in the online planning technique of temporary high-dose-rate brachytherapy for prostate cancer. METHODS AND MATERIALS Dose-volume constraints were defined delivering a prescription dose of 8.5Gy for CTV1 (whole prostate) and 15Gy for CTV2 (peripheral zone). A total of 38 implants of 20 patients were inversely planned using the constraints and dose indices (D90 CTV1,2; V200 CTV1,2; D2 cc rectum; D0.1 cc urethra; dose nonhomogeneity ratio; and conformal index) compared against those derived from conventional planning (CP). RESULTS The inversely planned (IP) treatment plans showed similar target volume coverage than by CP. The value of D90 CTV1 for CP was 5.62Gy and 5.63Gy for IPs. For CTV2, the D90 was also similar between both methods: 11.03Gy and 10.89Gy, respectively. Only V200 CTV2 was found to be significantly lower for CP than for IP: 5.76% vs. 8.14% (p<0.01). Values for D0.1 cc urethra were found to be: 9.57Gy and 9.02Gy, respectively. Rectal dosimetry: D2 cc Rectum was quite stable with 6.04Gy and 6.12Gy for CP and IP, respectively. The conformal index and dose nonhomogeneity ratio values for CTV1 and CTV2 for both planning types were very similar. CONCLUSIONS After defining an objective second target volume CTV2 and introducing adequate IP constraints to the treatment planning system, clinically applicable treatment plans could be created by an IP approach. They feature user independency, time saving, and good preservation of the OARs.
Collapse
Affiliation(s)
- Frank-André Siebert
- University Hospital of Schleswig-Holstein, Campus Kiel, Clinic of Radiotherapy, Kiel, Germany.
| | - Sabine Wolf
- University Hospital of Schleswig-Holstein, Campus Kiel, Clinic of Radiotherapy, Kiel, Germany
| | | | | | - Gunnar Bockelmann
- University Hospital of Schleswig-Holstein, Campus Kiel, Clinic of Radiotherapy, Kiel, Germany
| | - Bernhard Kimmig
- University Hospital of Schleswig-Holstein, Campus Kiel, Clinic of Radiotherapy, Kiel, Germany
| |
Collapse
|
18
|
Lapuz C, Dempsey C, Capp A, O'Brien PC. Dosimetric comparison of optimization methods for multichannel intracavitary brachytherapy for superficial vaginal tumors. Brachytherapy 2013; 12:637-44. [PMID: 23850274 DOI: 10.1016/j.brachy.2013.04.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2013] [Revised: 03/27/2013] [Accepted: 04/10/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE Multichannel vaginal applicators allow treatment of a more conformal volume compared with a single, central vaginal channel. There are several optimization methods available for use with multichannel applicators, but no previous comparison of these has been performed in the treatment of superficial vaginal tumors. Accordingly, a feasibility study was completed to compare inverse planning by simulated annealing (IPSA), dose point optimization (DPO), and graphical optimization for high-dose-rate brachytherapy using a multichannel, intracavitary vaginal cylinder. METHODS AND MATERIALS This comparative study used CT data sets from five patients with superficial vaginal recurrences of endometrial cancer treated with multichannel intracavitary high-dose-rate brachytherapy. Treatment plans were generated using DPO, graphical optimization, surface optimization with IPSA (surf IPSA), and two plans using volume optimization with IPSA. The plans were evaluated for target coverage, conformal index, dose homogeneity index, and dose to organs at risk. RESULTS Best target coverage was achieved by volume optimization with IPSA 2 and surf IPSA with mean V100 values of 93.89% and 91.87%, respectively. Doses for the most exposed 2-cm(3) of the bladder (bladder D2cc) was within tolerance for all optimization methods. Rectal D2cc was above tolerance for one DPO plan. All volume optimization with IPSA plans resulted in higher vaginal mucosa doses for all patients. Greatest homogeneity within the target volume was seen with surf IPSA and DPO. Highest conformal indices were seen with surf IPSA and graphical optimization. CONCLUSIONS Optimization with surf IPSA was user friendly for the generation of treatment plans and achieved good target coverage, conformity, and homogeneity with acceptable doses to organs at risk.
Collapse
Affiliation(s)
- Carminia Lapuz
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, New South Wales, Australia; Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
| | | | | | | |
Collapse
|
19
|
Does help structures play a role in reducing the variation of dwell time in IPSA planning for gynaecological brachytherapy application? J Contemp Brachytherapy 2011; 3:142-9. [PMID: 23346124 PMCID: PMC3551358 DOI: 10.5114/jcb.2011.24821] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2011] [Revised: 06/28/2011] [Accepted: 07/22/2011] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To report our experience of dosimetric comparison of IPSA and manual plans, with a focus on the use of help structures (HS) during optimization. MATERIAL AND METHODS 33 patients who underwent MR image-based HDR intracavitary-brachytherapy for cervix cancer based on GYN-ESTRO recommendations were selected for evaluation. Tandem/ovoid (T/O) and Vienna applicators were used. HS of diameter of 5 mm were drawn around the tandem/needles/ovoid and ring. Three plans were generated: manual optimized plan (MOPT), IPSA without help structures (IPSA_woHS) and IPSA with help structures (IPSA_wHS). Dose-volume parameters and the loading pattern were evaluated. RESULTS For T/O, the use of HS did not make significant impact in the dose-volume parameters and in the loading of tandem and ovoids, however steep variation was found in the individual dwell time. In case of Vienna applicator, inclusion of HS in the optimization made a significant impact in loading of needles. The percentage ratio of total time of needles to the tandem (T(N/T%)) was found to be 14±2.5, 53±9, 22±6 for MOPT, IPSA_woHS and IPSA_wHS, respectively, which implies that in IPSA_woHS the dwell time in needles were half of the dwell time in the tandem, while in MOPT the needles were loaded only in 14%, and in IPSA_wHS it was 22% of the dwell time of tandem. Inclusion of HS in the optimization has reduced the contribution of dwell time of needle in IPSA_wHS. The individual variation of dwell time was also reduced in IPSA_wHS, however drawing of HS is a time consuming procedure and may not be practical for a routine practice. CONCLUSION The role of HS was evaluated for IPSA for T/O and Vienna-applicator, the use of HS may be beneficial in case of combined intracavitary - interstitial approach.
Collapse
|
20
|
Biological equivalence between LDR and PDR in cervical cancer: multifactor analysis using the linear-quadratic model. J Contemp Brachytherapy 2011; 3:134-41. [PMID: 23346123 PMCID: PMC3551353 DOI: 10.5114/jcb.2011.24820] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2011] [Revised: 08/15/2011] [Accepted: 09/02/2011] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this work was the biological comparison between Low Dose Rate (LDR) and Pulsed Dose Rate (PDR) in cervical cancer regarding the discontinuation of the afterloading system used for the LDR treatments at our Institution since December 2009. Material and methods In the first phase we studied the influence of the pulse dose and the pulse time in the biological equivalence between LDR and PDR treatments using the Linear Quadratic Model (LQM). In the second phase, the equivalent dose in 2 Gy/fraction (EQD2) for the tumor, rectum and bladder in treatments performed with both techniques was evaluated and statistically compared. All evaluated patients had stage IIB cervical cancer and were treated with External Beam Radiotherapy (EBRT) plus two Brachytherapy (BT) applications. Data were collected from 48 patients (26 patients treated with LDR and 22 patients with PDR). Results In the analyses of the influence of PDR parameters in the biological equivalence between LDR and PDR treatments (Phase 1), it was calculated that if the pulse dose in PDR was kept equal to the LDR dose rate, a small the-rapeutic loss was expected. If the pulse dose was decreased, the therapeutic window became larger, but a correction in the prescribed dose was necessary. In PDR schemes with 1 hour interval between pulses, the pulse time did not influence significantly the equivalent dose. In the comparison between the groups treated with LDR and PDR (Phase 2) we concluded that they were not equivalent, because in the PDR group the total EQD2 for the tumor, rectum and bladder was smaller than in the LDR group; the LQM estimated that a correction in the prescribed dose of 6% to 10% was ne-cessary to avoid therapeutic loss. Conclusions A correction in the prescribed dose was necessary; this correction should be achieved by calculating the PDR dose equivalent to the desired LDR total dose.
Collapse
|