Arkhypova V, Soldatkin O, Soldatkin A, Dzyadevych S. Electrochemical Biosensors Based on Enzyme Inhibition Effect. CHEM REC 2024; 24:e202300214. [PMID: 37639188 DOI: 10.1002/tcr.202300214] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/07/2023] [Indexed: 08/29/2023]
Abstract
Several electrochemical biosensors based on various enzyme inhibition effects have been designed; their laboratory prototypes have been manufactured and thoroughly investigated. It should be noted that such biosensors are adapted to large-scale production technologies. A number of advantages and disadvantages of developed biosensors based on enzyme inhibition has been discussed. It is important that all developed biosensors are not opposite to traditional analytical methods, but complement them. This is an additional system of quick and early warning about the presence of toxic substances in the environment. Such systems can save time and money in emergencies due to the possibility of quick decision-making on local environmental problems. If necessary, more accurate, but time-consuming and expensive traditional methods could be used for further validation and additional research of samples previously tested by biosensors.
Collapse
Affiliation(s)
- Valentyna Arkhypova
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143, Kyiv, Ukraine
| | - Oleksandr Soldatkin
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143, Kyiv, Ukraine
| | - Alexei Soldatkin
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143, Kyiv, Ukraine
- Institute of High Technologies, Taras Shevchenko National University, 4G Glushkova av., 03022, Kyiv, Ukraine
| | - Sergei Dzyadevych
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143, Kyiv, Ukraine
- Institute of High Technologies, Taras Shevchenko National University, 4G Glushkova av., 03022, Kyiv, Ukraine
| |
Collapse
|
2
|
Kucherenko IS, Soldatkin OO, Dzyadevych SV, Soldatkin AP. Application of zeolites and zeolitic imidazolate frameworks in the biosensor development. BIOMATERIALS ADVANCES 2022; 143:213180. [PMID: 36375221 DOI: 10.1016/j.bioadv.2022.213180] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 10/24/2022] [Accepted: 10/29/2022] [Indexed: 06/16/2023]
Abstract
Biosensors are advanced devices for analysis of composition of blood, urine, environmental samples, and many other media. Their current development is tightly linked with nanomaterials, such as zeolites and zeolitic imidazolate framework (ZIFs). The present review describes electrochemical (amperometric, conductometric, ISFET) and optical (fluorescent and colorimetric) biosensors that incorporate zeolites and ZIFs in their biorecognition elements. The biosensors are based on immobilized enzymes (such as glucose oxidase, urease, and acetylcholinesterase), antibodies, DNA, and aptamers. The review present reasons for application of these nanomaterials, and discusses advantages of zeolite- and ZIF-containing biosensors over other biosensors. In most cases, the biosensors have improved sensitivity, better limit of detection, wider linear range, and other improved characteristics. It is demonstrated that immobilization of biomolecules such as enzymes or antibodies on the surface of zeolites and ZIFs enables creation of unique advanced biosensors that have a potential for further development and practical applications.
Collapse
Affiliation(s)
- I S Kucherenko
- Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo str., 03143 Kyiv, Ukraine; IQVIA, 12 Amosova str., 03038 Kyiv, Ukraine.
| | - O O Soldatkin
- Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo str., 03143 Kyiv, Ukraine; Taras Shevchenko Kyiv National University, 64 Volodymyrska str., 01601 Kyiv, Ukraine
| | - S V Dzyadevych
- Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo str., 03143 Kyiv, Ukraine; Taras Shevchenko Kyiv National University, 64 Volodymyrska str., 01601 Kyiv, Ukraine
| | - A P Soldatkin
- Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo str., 03143 Kyiv, Ukraine; Taras Shevchenko Kyiv National University, 64 Volodymyrska str., 01601 Kyiv, Ukraine
| |
Collapse
|
3
|
|
4
|
Morales MA, Halpern JM. Guide to Selecting a Biorecognition Element for Biosensors. Bioconjug Chem 2018; 29:3231-3239. [PMID: 30216055 DOI: 10.1021/acs.bioconjchem.8b00592] [Citation(s) in RCA: 184] [Impact Index Per Article: 30.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Biosensors are powerful diagnostic tools defined as having a biorecognition element for analyte specificity and a transducer for a quantifiable signal. There are a variety of different biorecognition elements, each with unique characteristics. Understanding the advantages and disadvantages of each biorecognition element and their influence on overall biosensor performance is crucial in the planning stages to promote the success of novel biosensor development. Therefore, this review will focus on selecting the optimal biorecognition element in the preliminary design phase for novel biosensors. Included is a review of the typical characteristics and binding mechanisms of various biorecognition elements, and how they relate to biosensor performance characteristics, specifically sensitivity, selectivity, reproducibility, and reusability. The goal is to point toward language needed to improve the design and development of biosensors toward clinical success.
Collapse
Affiliation(s)
- Marissa A Morales
- Department of Chemical Engineering , University of New Hampshire , Durham , New Hampshire 03824 , United States
| | - Jeffrey Mark Halpern
- Department of Chemical Engineering , University of New Hampshire , Durham , New Hampshire 03824 , United States
| |
Collapse
|
5
|
Stasyuk N, Gayda G, Zakalskiy A, Zakalska O, Errachid A, Gonchar M. Highly selective apo-arginase based method for sensitive enzymatic assay of manganese (II) and cobalt (II) ions. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 193:349-356. [PMID: 29268235 DOI: 10.1016/j.saa.2017.12.031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 11/27/2017] [Accepted: 12/05/2017] [Indexed: 06/07/2023]
Abstract
A novel enzymatic method of manganese (II) and cobalt (II) ions assay, based on using apo-enzyme of Mn2+-dependent recombinant arginase I (arginase) and 2,3-butanedione monoxime (DMO) as a chemical reagent is proposed. The principle of the method is the evaluation of the activity of L-arginine-hydrolyzing of arginase holoenzyme after the specific binding of Mn2+ or Co2+ with apo-arginase. Urea, which is the product of enzymatic hydrolysis of L-arginine (Arg), reacts with DMO and the resulted compound is detected by both fluorometry and visual spectrophotometry. Thus, the content of metal ions in the tested samples can be determined by measuring the level of urea generated after enzymatic hydrolysis of Arg by reconstructed arginase holoenzyme in the presence of tested metal ions. The linearity range of the fluorometric apo-arginase-DMO method in the case of Mn2+ assay is from 4pM to 1.10nM with a limit of detection of 1pM Mn2+, whereas the linearity range of the present method in the case of Co2+ assay is from 8pM to 45nM with a limit of detection of 2.5pM Co2+. The proposed method being highly sensitive, selective, valid and low-cost, may be useful to monitor Mn2+ and Co2+ content in clinical laboratories, food industry and environmental control service.
Collapse
Affiliation(s)
- Nataliya Stasyuk
- Department of Analytical Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Str. 14/16, Lviv 79005, Ukraine
| | - Galina Gayda
- Department of Analytical Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Str. 14/16, Lviv 79005, Ukraine
| | - Andriy Zakalskiy
- Department of Analytical Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Str. 14/16, Lviv 79005, Ukraine
| | - Oksana Zakalska
- Department of Analytical Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Str. 14/16, Lviv 79005, Ukraine
| | - Abdelhamid Errachid
- Université de Lyon, Analytical Sciences Institute, UMR CNRS 5180, CNRS, Université de Lyon 1, ENS Lyon, 5 rue de la Doua, F-69100 Villeurbanne Cedex, France
| | - Mykhailo Gonchar
- Department of Analytical Biotechnology, Institute of Cell Biology, NAS of Ukraine, Drahomanov Str. 14/16, Lviv 79005, Ukraine.
| |
Collapse
|
6
|
Soldatkina OV, Soldatkin OO, Kasap BO, Kucherenko DY, Kucherenko IS, Kurc BA, Dzyadevych SV. A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite. NANOSCALE RESEARCH LETTERS 2017; 12:260. [PMID: 28395478 PMCID: PMC5383914 DOI: 10.1186/s11671-017-2026-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Accepted: 03/29/2017] [Indexed: 05/13/2023]
Abstract
In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via adsorption on silicalite particles. The disc platinum electrode (d = 0.4 mm) was used as the amperometric sensor. The procedure of biosensor preparation was optimized. The main parameters of modifying amperometric transducers with a silicalite layer were determined along with the procedure of GlOx adsorption on this layer. The biosensors based on GlOx adsorbed on silicalite demonstrated high sensitivity to glutamate. The linear range of detection was from 2.5 to 450 μM, and the limit of glutamate detection was 1 μM. It was shown that the proposed biosensors were characterized by good response reproducibility during hours of continuous work and operational stability for several days. The developed biosensors could be applied for determination of glutamate in real samples.
Collapse
Affiliation(s)
- O. V. Soldatkina
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01003 Ukraine
| | - O. O. Soldatkin
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01003 Ukraine
- Institute of Molecular Biology and Genetics of NAS of Ukraine, Zabolotnogo Street 150, Kyiv, 03143 Ukraine
| | - B. Ozansoy Kasap
- Micro and Nanotechnology Department, Middle East Technical University, 06531 Ankara, Turkey
| | - D. Yu. Kucherenko
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01003 Ukraine
| | - I. S. Kucherenko
- Institute of Molecular Biology and Genetics of NAS of Ukraine, Zabolotnogo Street 150, Kyiv, 03143 Ukraine
| | - B. Akata Kurc
- Micro and Nanotechnology Department, Middle East Technical University, 06531 Ankara, Turkey
- Central Laboratory, Middle East Technical University, 06531 Ankara, Turkey
| | - S. V. Dzyadevych
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01003 Ukraine
- Institute of Molecular Biology and Genetics of NAS of Ukraine, Zabolotnogo Street 150, Kyiv, 03143 Ukraine
| |
Collapse
|
7
|
Bakhmachuk A, Gorbatiuk O, Rachkov A, Dons'koi B, Khristosenko R, Ushenin I, Peshkova V, Soldatkin A. Surface Plasmon Resonance Investigations of Bioselective Element Based on the Recombinant Protein A for Immunoglobulin Detection. NANOSCALE RESEARCH LETTERS 2017; 12:112. [PMID: 28209032 PMCID: PMC5307396 DOI: 10.1186/s11671-017-1903-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Accepted: 02/06/2017] [Indexed: 06/06/2023]
Abstract
The developed surface plasmon resonance (SPR) biosensor based on the recombinant Staphylococcal protein A with an additional cysteine residue (SPA-Cys) used as a biorecognition component showed a good selectivity and sensitivity for the immunoglobulin detection. The developed biosensor with SPA-Cys-based bioselective element can also be used as a first step of immunosensor creation. The successful immobilization of SPA-Cys on the nanolayer gold sensor surface of the SPR spectrometer was performed. The efficiency of blocking nonspecific sorption sites on the sensor surface with milk proteins, gelatin, BSA, and HSA was studied, and a rather high efficiency of using gelatin was confirmed. The SPR biosensor selectively interacted with IgG and did not interact with the control proteins. The linear dependence of the sensor response on the IgG concentration in the range from 2 to 10 μg/ml was shown. Using the calibration curve, the IgG concentration was measured in the model samples. The determined concentrations are in good agreement (r 2 = 0.97) with the given concentration of IgG.
Collapse
Affiliation(s)
- A Bakhmachuk
- Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03680, Kyiv, Ukraine.
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, 2, korp.5, Pr. Akademika Hlushkova, Kyiv, 03022, Ukraine.
| | - O Gorbatiuk
- Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03680, Kyiv, Ukraine
- State Institute of Genetic and Regenerative Medicine, NAMS of Ukraine, 57/3, Velyka Vasyl'kivska Str., Kyiv, 03150, Ukraine
| | - A Rachkov
- Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03680, Kyiv, Ukraine
| | - B Dons'koi
- Institute of Pediatrics, Obstetrics and Gynecology, NAMS of Ukraine, 8, Maiborody Str., Kyiv, 04050, Ukraine
| | - R Khristosenko
- V.E. Lashkaryov Institute of Semiconductor Physics, NAS of Ukraine, 41, Prospect Nauki, Kyiv, 03028, Ukraine
| | - I Ushenin
- V.E. Lashkaryov Institute of Semiconductor Physics, NAS of Ukraine, 41, Prospect Nauki, Kyiv, 03028, Ukraine
| | - V Peshkova
- Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03680, Kyiv, Ukraine
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, 2, korp.5, Pr. Akademika Hlushkova, Kyiv, 03022, Ukraine
| | - A Soldatkin
- Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03680, Kyiv, Ukraine
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, 2, korp.5, Pr. Akademika Hlushkova, Kyiv, 03022, Ukraine
| |
Collapse
|
8
|
Rahman MM, Hussain MM, Asiri AM. Ultrasensitive and label-free detection of creatine based on CdO nanoparticles: a real sample approach. NEW J CHEM 2017. [DOI: 10.1039/c6nj04101a] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Low-dimensional cadmium oxide nanoparticles (CdO NPs) were prepared by a facile wet-chemical method, which later electrochemically investigated for the determination of selective creatine and measured the analytical sensor parameters such as sensitivity, limit of detection (LOD), linear dynamic range (LDR), long-term stability, and real-sample validation.
Collapse
Affiliation(s)
- Mohammed M. Rahman
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| | | | - Abdullah M. Asiri
- Chemistry Department
- Faculty of Science
- King Abdulaziz University
- Jeddah 21589
- Saudi Arabia
| |
Collapse
|
9
|
Boysen RI, Schwarz LJ, Nicolau DV, Hearn MTW. Molecularly imprinted polymer membranes and thin films for the separation and sensing of biomacromolecules. J Sep Sci 2016; 40:314-335. [PMID: 27619154 DOI: 10.1002/jssc.201600849] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Revised: 07/31/2016] [Accepted: 08/29/2016] [Indexed: 01/25/2023]
Abstract
This review describes recent advances associated with the development of surface imprinting methods for the synthesis of polymeric membranes and thin films, which possess the capability to selectively and specifically recognize biomacromolecules, such as proteins and single- and double-stranded DNA, employing "epitope" or "whole molecule" approaches. Synthetic procedures to create different molecularly imprinted polymer membranes or thin films are discussed, including grafting/in situ polymerization, drop-, dip-, or spin-coating procedures, electropolymerization as well as micro-contact or stamp lithography imprinting methods. Highly sensitive techniques for surface characterization and analyte detection are described, encompassing luminescence and fluorescence spectroscopy, X-ray photoelectron spectroscopy, FTIR spectroscopy, surface-enhanced Raman spectroscopy, atomic force microscopy, quartz crystal microbalance analysis, cyclic voltammetry, and surface plasmon resonance. These developments are providing new avenues to produce bioelectronic sensors and new ways to explore through advanced separation science procedures complex phenomena associated with the origins of biorecognition in nature.
Collapse
Affiliation(s)
- Reinhard I Boysen
- Australian Centre for Research on Separation Science (ACROSS), Centre for Green Chemistry, Monash University, Melbourne, Australia
| | - Lachlan J Schwarz
- Australian Centre for Research on Separation Science (ACROSS), Centre for Green Chemistry, Monash University, Melbourne, Australia.,School of Agricultural and Wine Sciences, Faculty of Science, Charles Sturt University, Wagga Wagga, Australia
| | - Dan V Nicolau
- Australian Centre for Research on Separation Science (ACROSS), Centre for Green Chemistry, Monash University, Melbourne, Australia.,Department of Bioengineering, Faculty of Engineering, McGill University, Montreal, Canada
| | - Milton T W Hearn
- Australian Centre for Research on Separation Science (ACROSS), Centre for Green Chemistry, Monash University, Melbourne, Australia
| |
Collapse
|
10
|
Shkotova LV, Piechniakova NY, Kukla OL, Dzyadevych SV. Thin-film amperometric multibiosensor for simultaneous determination of lactate and glucose in wine. Food Chem 2015; 197:972-8. [PMID: 26617042 DOI: 10.1016/j.foodchem.2015.11.066] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 09/21/2015] [Accepted: 11/13/2015] [Indexed: 12/17/2022]
Abstract
An amperometric multi-biosensor based on lactate and glucose oxidases has been developed for determination of lactate and glucose in wine. Gold thin-film amperometric electrodes were used as multi-transducers. Analytical characteristics of the multi-biosensor developed were studied. The minimum detectable concentration was 5×10(-6) mol/l for both glucose and lactate. High reproducibility and storage stability of the multi-biosensor are demonstrated in this paper. Lactate and glucose were determined in wine, and a good correlation was obtained with concentrations determined using high-performance liquid chromatography (correlation coefficient for glucose R(2)=0.998, for lactate R(2)=0.718).
Collapse
Affiliation(s)
- Lyudmyla V Shkotova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143 Kyiv, Ukraine.
| | - Nataliia Y Piechniakova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143 Kyiv, Ukraine; National Taras Shevchenko University of Kyiv, Educational and Scientific Centre «Institute of Biology», 2 Glushkova Str., Block 12, 03022 Kyiv, Ukraine
| | - Oleksandr L Kukla
- Institute of Semiconductor Physics, National Academy of Sciences of Ukraine, 41 Nauki Prosp., 03028 Kyiv, Ukraine
| | - Sergei V Dzyadevych
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., 03143 Kyiv, Ukraine
| |
Collapse
|
11
|
Kucherenko IS, Soldatkin OO, Lagarde F, Jaffrezic-Renault N, Dzyadevych SV, Soldatkin AP. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase. Talanta 2015; 144:604-11. [PMID: 26452867 DOI: 10.1016/j.talanta.2015.06.079] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 06/24/2015] [Accepted: 06/26/2015] [Indexed: 10/23/2022]
Abstract
Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes.
Collapse
Affiliation(s)
- I S Kucherenko
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotny Str., Kyiv 03680, Ukraine; Taras Shevchenko National University of Kyiv, 64 Volodymyrska Str., 01003 Kyiv, Ukraine; Institute of Analytical Sciences, UMR5280 CNRS/UCBL/ENS, 5 rue de la Doua, 69100 Villeurbanne, France.
| | - O O Soldatkin
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotny Str., Kyiv 03680, Ukraine; Taras Shevchenko National University of Kyiv, 64 Volodymyrska Str., 01003 Kyiv, Ukraine
| | - F Lagarde
- Institute of Analytical Sciences, UMR5280 CNRS/UCBL/ENS, 5 rue de la Doua, 69100 Villeurbanne, France
| | - N Jaffrezic-Renault
- Institute of Analytical Sciences, UMR5280 CNRS/UCBL/ENS, 5 rue de la Doua, 69100 Villeurbanne, France
| | - S V Dzyadevych
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotny Str., Kyiv 03680, Ukraine; Taras Shevchenko National University of Kyiv, 64 Volodymyrska Str., 01003 Kyiv, Ukraine
| | - A P Soldatkin
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine, 150 Zabolotny Str., Kyiv 03680, Ukraine; Taras Shevchenko National University of Kyiv, 64 Volodymyrska Str., 01003 Kyiv, Ukraine
| |
Collapse
|
12
|
Kucherenko I, Soldatkin O, Kasap BO, Kirdeciler SK, Kurc BA, Jaffrezic-Renault N, Soldatkin A, Lagarde F, Dzyadevych S. Nanosized zeolites as a perspective material for conductometric biosensors creation. NANOSCALE RESEARCH LETTERS 2015; 10:209. [PMID: 25991913 PMCID: PMC4429111 DOI: 10.1186/s11671-015-0911-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Accepted: 04/25/2015] [Indexed: 05/23/2023]
Abstract
In this work, the method of enzyme adsorption on different zeolites and mesoporous silica spheres (MSS) was investigated for the creation of conductometric biosensors. The conductometric transducers consisted of gold interdigitated electrodes were placed on the ceramic support. The transducers were modified with zeolites and MSS, and then the enzymes were adsorbed on the transducer surface. Different methods of zeolite attachment to the transducer surface were used; drop coating with heating to 200°C turned out to be the best one. Nanozeolites beta and L, zeolite L, MSS, and silicalite-1 (80 to 450 nm) were tested as the adsorbents for enzyme urease. The biosensors with all tested particles except zeolite L had good analytical characteristics. Silicalite-1 (450 nm) was also used for adsorption of glucose oxidase, acetylcholinesterase, and butyrylcholinesterase. The glucose and acetylcholine biosensors were successfully created, whereas butyrylcholinesterase was not adsorbed on silicalite-1. The enzyme adsorption on zeolites and MSS is simple, quick, well reproducible, does not require use of toxic compounds, and therefore can be recommended for the development of biosensors when these advantages are especially important.
Collapse
Affiliation(s)
- Ivan Kucherenko
- />Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03680 Kyiv, Ukraine
- />Taras Shevchenko National University of Kyiv, Volodymyrska Street, 64, 01601 Kyiv, Ukraine
- />Institute of Analytical Sciences, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Oleksandr Soldatkin
- />Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03680 Kyiv, Ukraine
- />Taras Shevchenko National University of Kyiv, Volodymyrska Street, 64, 01601 Kyiv, Ukraine
| | - Berna Ozansoy Kasap
- />Central Laboratory, Middle East Technical University, Dumlupinar Bulvari, 1, 06800 Ankara, Turkey
| | - Salih Kaan Kirdeciler
- />Central Laboratory, Middle East Technical University, Dumlupinar Bulvari, 1, 06800 Ankara, Turkey
| | - Burcu Akata Kurc
- />Central Laboratory, Middle East Technical University, Dumlupinar Bulvari, 1, 06800 Ankara, Turkey
- />Micro and Nanotechnology Department, Middle East Technical University, Dumlupinar Bulvari, 1, 06800 Ankara, Turkey
| | | | - Alexei Soldatkin
- />Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03680 Kyiv, Ukraine
- />Taras Shevchenko National University of Kyiv, Volodymyrska Street, 64, 01601 Kyiv, Ukraine
| | - Florence Lagarde
- />Institute of Analytical Sciences, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Sergei Dzyadevych
- />Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, 03680 Kyiv, Ukraine
- />Taras Shevchenko National University of Kyiv, Volodymyrska Street, 64, 01601 Kyiv, Ukraine
| |
Collapse
|
13
|
Stepurska K, Soldatkin О, Kucherenko I, Arkhypova V, Dzyadevych S, Soldatkin A. Feasibility of application of conductometric biosensor based on acetylcholinesterase for the inhibitory analysis of toxic compounds of different nature. Anal Chim Acta 2015; 854:161-8. [DOI: 10.1016/j.aca.2014.11.027] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 10/25/2014] [Accepted: 11/18/2014] [Indexed: 11/25/2022]
|