1
|
Ferrandino G, De Palo G, Murgia A, Birch O, Tawfike A, Smith R, Debiram-Beecham I, Gandelman O, Kibble G, Lydon AM, Groves A, Smolinska A, Allsworth M, Boyle B, van der Schee MP, Allison M, Fitzgerald RC, Hoare M, Snowdon VK. Breath Biopsy ® to Identify Exhaled Volatile Organic Compounds Biomarkers for Liver Cirrhosis Detection. J Clin Transl Hepatol 2023; 11:638-648. [PMID: 36969895 PMCID: PMC10037526 DOI: 10.14218/jcth.2022.00309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/30/2022] [Accepted: 11/01/2022] [Indexed: 03/29/2023] Open
Abstract
Background and Aims The prevalence of chronic liver disease in adults exceeds 30% in some countries and there is significant interest in developing tests and treatments to help control disease progression and reduce healthcare burden. Breath is a rich sampling matrix that offers non-invasive solutions suitable for early-stage detection and disease monitoring. Having previously investigated targeted analysis of a single biomarker, here we investigated a multiparametric approach to breath testing that would provide more robust and reliable results for clinical use. Methods To identify candidate biomarkers we compared 46 breath samples from cirrhosis patients and 42 from controls. Collection and analysis used Breath Biopsy OMNI™, maximizing signal and contrast to background to provide high confidence biomarker detection based upon gas chromatography mass spectrometry (GC-MS). Blank samples were also analyzed to provide detailed information on background volatile organic compounds (VOCs) levels. Results A set of 29 breath VOCs differed significantly between cirrhosis and controls. A classification model based on these VOCs had an area under the curve (AUC) of 0.95±0.04 in cross-validated test sets. The seven best performing VOCs were sufficient to maximize classification performance. A subset of 11 VOCs was correlated with blood metrics of liver function (bilirubin, albumin, prothrombin time) and separated patients by cirrhosis severity using principal component analysis. Conclusions A set of seven VOCs consisting of previously reported and novel candidates show promise as a panel for liver disease detection and monitoring, showing correlation to disease severity and serum biomarkers at late stage.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Irene Debiram-Beecham
- Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Cambridge, UK
| | | | - Graham Kibble
- Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Cambridge, UK
| | - Anne Marie Lydon
- Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Cambridge, UK
| | - Alice Groves
- Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Cambridge, UK
| | - Agnieszka Smolinska
- Owlstone Medical, Cambridge, UK
- Department of Pharmacology and Toxicology, School for Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University Medical Center, the Netherlands
| | | | | | | | - Michael Allison
- Department of Medicine, University of Cambridge, Addenbrooke’s Hospital, Cambridge, UK
- Addenbrookes Hepatology and Liver Transplantation Unit, Addenbrookes Hospital, Cambridge, UK
| | - Rebecca C. Fitzgerald
- MRC Cancer Unit, Hutchison/MRC Research Centre, University of Cambridge, Cambridge, UK
| | - Matthew Hoare
- Department of Medicine, University of Cambridge, Addenbrooke’s Hospital, Cambridge, UK
- Addenbrookes Hepatology and Liver Transplantation Unit, Addenbrookes Hospital, Cambridge, UK
- CRUK Cambridge Institute, Cambridge, UK
| | - Victoria K. Snowdon
- Addenbrookes Hepatology and Liver Transplantation Unit, Addenbrookes Hospital, Cambridge, UK
| |
Collapse
|
2
|
Ferrandino G, Orf I, Smith R, Calcagno M, Thind AK, Debiram-Beecham I, Williams M, Gandelman O, de Saedeleer A, Kibble G, Lydon AM, Mayhew CA, Allsworth M, Boyle B, van der Schee MP, Allison M, Hoare M, Snowdon VK. Breath Biopsy Assessment of Liver Disease Using an Exogenous Volatile Organic Compound-Toward Improved Detection of Liver Impairment. Clin Transl Gastroenterol 2020; 11:e00239. [PMID: 33094960 PMCID: PMC7498135 DOI: 10.14309/ctg.0000000000000239] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 07/21/2020] [Indexed: 12/29/2022] Open
Abstract
INTRODUCTION Liver cirrhosis and its complication - hepatocellular carcinoma (HCC) - have been associated with increased exhaled limonene. It is currently unclear whether this increase is more strongly associated with the presence of HCC or with the severity of liver dysfunction. METHODS We compared the exhaled breath of 40 controls, 32 cirrhotic patients, and 12 cirrhotic patients with HCC using the Breath Biopsy platform. Breath samples were analyzed by thermal desorption-gas chromatography-mass spectrometry. Limonene levels were compared between the groups and correlated to bilirubin, albumin, prothrombin time international normalized ratio, and alanine aminotransferase. RESULTS Breath limonene concentration was significantly elevated in subjects with cirrhosis-induced HCC (M: 82.1 ng/L, interquartile range [IQR]: 16.33-199.32 ng/L) and cirrhosis (M: 32.6 ng/L, IQR: 6.55-123.07 ng/L) compared with controls (M: 6.2 ng/L, IQR: 2.62-9.57 ng/L) (P value = 0.0005 and 0.0001, respectively) with no significant difference between 2 diseased groups (P value = 0.37). Levels of exhaled limonene correlated with serum bilirubin (R = 0.25, P value = 0.0016, r = 0.51), albumin (R = 0.58, P value = 5.3e-8, r = -0.76), and international normalized ratio (R = 0.29, P value = 0.0003, r = 0.51), but not with alanine aminotransferase (R = 0.01, P value = 0.36, r = 0.19). DISCUSSION Exhaled limonene levels are primarily affected by the presence of cirrhosis through reduced liver functional capacity, as indicated by limonene correlation with blood metrics of impaired hepatic clearance and protein synthesis capacity, without further alterations observed in subjects with HCC. This suggests that exhaled limonene is a potential non-invasive marker of liver metabolic capacity (see Visual abstract, Supplementary Digital Content 1, http://links.lww.com/CTG/A388).
Collapse
Affiliation(s)
| | - Isabel Orf
- Owlstone Medical, Cambridge, UK
- Current affiliation: Human Metabolome Technologies, Leiden, the Netherlands
| | | | | | | | - Irene Debiram-Beecham
- Department of Oncology, Hutchison/MRC Research Centre, University of Cambridge, Cambridge, UK
| | | | | | | | - Graham Kibble
- Department of Oncology, Hutchison/MRC Research Centre, University of Cambridge, Cambridge, UK
| | - Anne Marie Lydon
- Department of Oncology, Hutchison/MRC Research Centre, University of Cambridge, Cambridge, UK
| | - Chris A. Mayhew
- Institute for Breath Research, Leopold-Franzens-Universität Innsbruck, Dornbirn, Austria
- Molecular Physics Group, School of Physics and Astronomy, University of Birmingham, Birmingham, UK
| | | | | | | | - Michael Allison
- Department of Medicine, Cambridge Biomedical Research Centre, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Addenbrooke's Hepatology and Liver Transplantation Unit, Addenbrooke's Hospital, Cambridge, UK
| | - Matthew Hoare
- Addenbrooke's Hepatology and Liver Transplantation Unit, Addenbrooke's Hospital, Cambridge, UK
- CRUK Cambridge Institute, Cambridge, UK
- Department of Medicine, University of Cambridge, Addenbrooke's Hospital, Cambridge, UK
| | - Victoria K. Snowdon
- Addenbrooke's Hepatology and Liver Transplantation Unit, Addenbrooke's Hospital, Cambridge, UK
| |
Collapse
|